Loading...
RC-000417-2017 4111WTOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000417-2017 Date Issued: Monday,November 27, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000417-2017 has been completed. Tax Map Number: 308.8-1-80 Location: 71 BURNT HILLS DR Owner: Michaels Group Homes,LLC Applicant: Michaels Group Homes,LLC This structure may be occupied as a: Single Family Dwelling 2299 s.f. Garage 440 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, 4 Variance, or other issues and conditions as a result of approvals by the Director Building&Code En ement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000417-2017 Tax Map No: 308.8-1-80 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 71 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $300,000.00 Owner Address: 10 Blacksmith DR Total Value $300,000.00 Malta,NY 12020 Contractor or Builder's Name/Address Electrical Inspection Agency Tony LoCascio 20 OGDEN RD Queensbury,NY 12804 Plans&Specifications Single Family Dwelling 2299 s.f. Garage 440 s.f. $1,375.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,July 24,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensb beforeYA ' tionA date .) Dated at the Town of ueensb /jvton�'�17 SIGNED BY: � for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL, S'T'RUCTURE APPLICATION Office Use Only Date: `7)1e)1-7 Permit No. QC-q.l'�' -201�} Tax Map ID Permit Fee > Zone Historic? Yes No Rec Fee Subdivision Name lauR.uT lubGE(L-a 16_Lot# � O t Subdivision# Project Location -71 t6%94)1 • HIL%.s A2\Vc TOWN 80,RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit feels). Primary Owner(s) MIC _H045 Ck H 1 Ll L Address MAJAOMc6 I,jL ! MFxF1AnitcVlL�E Pim/ tZ11H Phone/Email rel$ • 2fiq,to3ll Applicant 3r•r-te A� P-�pV.= Address Phone/Email Contractor Say t dL Address Phone/Email Contact Person for Building& Codes Compliance: lib e ) 314 4- TYPE OF CONSTRUCTION ,/Check all that apply New Addition Alteration In floor sf 2nd floor sf Total sf Height Single Family 1 i 21 b 1,003 2,7-9q * Bd-etl_ Two-Family Multi-Family (#of units__) 2 (ra 0 1111 L5 2 Townhouse 15 l� V Business Office Retail-Mercantile BUILDI G& CODES Factory-Industrial Attached Garage (1,©3, 4+) -440 + Other Town of Queensbury Building&Codes Principal structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Isiw1Gi,-P, FiNAk l -e lZ�tp Source of Heat(circle one) a Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Mp Are there easements on the property? KO Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? _Yes _No c_ Will the grade be changed as a result of construction _Yes _No d. Public water or Private well(circle one) ubhc Private e. Sewer or Private Septic System(circle one) Sewerr vate Value of all work to be performed (labor or materials) $ 300,do a DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: / PRINT NAME: �, C SG/p DATE: II SIGNATURE: DATE: For office use only Operating Permit Issued: _Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL, APPLICATION Office Use Only Received DATE: 71 l nI 17 Tax Map ID TAx MAP ID: Permit No. ZONE: Permit Fee APPLICANT Pq IC44GIVr-;"2S, LLC PHONE/E-MAIL ADDRESS 1 MacclontS WASP NIc24tNJJtCVIIte IDLY 1211® INSTALLER/ GNbtAZS eXC.I qA-j KVAr, PHONE/E-MAIL 51e . 1q-1 . 93'tl BUILDER OWNER MIGHAV-S CtVX-„O tw"'es ,L_-C 5t6 .c69q .b311 ADDRESS -71 l-lw%-% (zb2%, 1I CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: 'rOiyY PHONE/E-MAIL 5367 -3144- RESIDENCE 3l44- RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flaw 1980 or older Garbage grinder installed Yes ),/No 1981-1991 Spa or Hot Tub installed _Yes XNo 1992-Present ( � O PARCEL INFORMATION Topography Flat rolling _Steep slope _%Slope Soil Nature __e,_Sand Loam _Clay _Other Groundwater At what depth: ,d Bedrock/Impervious material At what depth: YJA Domestic Water Supply Municipal _Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size 2 5 D gallons(min.size I,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with 92 stone Total length Z00 ft.;Each Trench IS- Seepage Seepage Pit with#3 stone How many: _;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. 1 have read the regulations and agree to abide by these and all requirements of the eT "Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: 1/ »+/ I/. 6'4';Ct ! DATE: 2b //7 SIGNATURE: 75� ,,- DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: -7 tc7 1-7 Applicant Name: M%C.Hc.1S GrlzoW t O"IeS,L�-c Telephone No.: 5%0 . T>Cjg.to 3t r Address to be Inspected -71 Q'%7-U"X "Lkk% J'jZ" S Return Address: 1 M)-f"MS t4AW. MEK-WANlL%LtLLe, Nse IZrt$ Applicant must show exact Iocation and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: O Preliminary approval NEED O Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" { ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 71 Burnt Hills Drive- Queensbury, NY HVAC Load Calculations for The Michaels Group 308.8-1-80 RC-000417-2017 Michael's Group Homes LLC 71 Burnt Hills Drive, Lot 36 SFD 2299 s_f., Garage 440 s-f. r R%sI1]�A mA , KVA C L,oAos U JUL 1 Z 20V p D Prepared By: _ I Chris Whittet TOWN OF OUEENSBURY Appolo Heating BUILDING a CODES 868 8urdeck Street --- — Schenectady, NY 12306 518.858-0433 Thursday,July 6,2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc 71 Burnt Hills Drive- Queensbury,NY 8chenectad NY 12306-.. ._ _ Pa e2 Project Report —I EQ'j Information Project Title: 71 Burnt Hills Drive-Queensbury, NY Designed By: Chris Whittet Project Date: Thursday,July 6, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Chris Whittet Company Address: 868 Burdeck Street Company City: Schenectady, NY 12306 Company Phone: 518-858-0433 Company E-Mail Address: chNsw@appoleheating.com Reference City: Schenectady, New York Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a 30% 70 28.27 Summer: 87 72 49% 50% 75 30 "IlBCIC_'{-'}tQ.. Total Building Supply CFM: 1,152 CFM Per Square ft.: 0.319 Square ft. of Room Area: 3,615 Square ft. Per Ton: 1,296 Volume(fl'): 29,961 Biildl6 Loads` ii k " . Total Heating Required Including Ventilation Air: 67,578 Btuh 67.578 MBH Total Sensible Gain: 27,744 Btuh 83 % Total Latent Gain: 5,720 Bluth 17 % Total Cooling Required Including Ventilation Air: 33,464 Btuh 2.79 Tons (Based On Sensible + Latent) Rhvac.is an ALGA approve-d Mattual J and Manual_D computer_program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\chrisw\Documents\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drtve.rh9 Thursday, July 6, 2017, 8:28 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc 71 Burnt Hills Drive Queensbury,NY Schenectady,NY 12306 _ Page 3 Miscellaneous Report stem 1 Outdoor Outdoor Outdoor Indoor Indoor hS Grains. :I❑ ut Data _ Dry Bulb Wet Bulb_ Rel.Hum Rei.Hutn Dry Bulb Diffefence' Winter: 1 0.31 80% 30% 70 28.27 Summer: 87 72 49% 50% 75 29.96 buct SjZjtaganputs " ' _ Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. -ll iAir:t l'l YtJlde Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 185 CFM 95 CFM Infiltration Actual: 0.000 AC/hr 0.000 AC/hr Building Volume: X 29.961 Cu.ft. X 29.961 Cu.ft. 0 Cu.ft./hr 0 Cu.ft.lhr X 0.0167 X 0.0167 Total Building Infiltration: 0 CFM 0 CFM Total Building Ventilation: 210 CFM 210 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(185 CFM), Construction: Average Summer Infiltration Specified: 0.190 AC/hr(95 CFM), Construction:Average C:\Users\chrfsw\Documents\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drive.rh9 Thursday, July 6, 2017, 8:28 AM Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,.lnc. Appolo Heating Inc 71 Burnt Hills Drive_- Queensbury;NY Scheneclad ,NY 12305 Page 4 Load Preview Report Has Net fV Sen Lel Net Sen Hlg Clg Bsl Ssl Acl Scope AED Ton /Tool Area Galnl Geln Gain Less CFM CFM CFM Brdldng 2.79 1,296 3,615 27,744 5,720 33,464 67,578 683 1,152 1,152 System 1 No 2.79 1296 3,615 27,744 5,720 33,464 67,578 683 1,152 1,152 Ventilation 2,734 4220 6,954 15.723 Humidification 7,484 Zone 1-CI g.:6%, Htg.:16% 1,218 1,771 0 1,771 6,992 108 82 82 1-Basement 1218 1,771 0 1,771 6,992 108 82 82 Zone 2-CIg.:42%,Htg:42% 1,164 11,965 0 11,965 18,582 286 551 551 2-Breakfast Nook 74 1,326 0 1,326 2.413 37 61 61 3.Ktchen 198 851 0 851 2,186 34 39 39 4-Great Room 311 2,213 0 2,213 5.099 78 102 102 5-Powder Room 26 585 0 585 546 8 27 27 6-Closet 14 189 0 189 105 2 9 9 7-Hall 91 32 385 0 385 246 4 18 18 &Stabs 43 570 0 570 332 5 26 26 9.Offlce 164 2,138 0 2,138 2,904 45 99 99 10-Foyer 90 735 0 735 1,129 17 34 34 11-Dining Room 152 2,119 0 2,119 2,780 43 98 98 12-Mud Roam 36 482 0 482 663 10 22 22 13-Hall#2 23 373 0 373 179 3 17 17 Zone 3-C19.:52%,Htg:42% 1,233 15,011 1,500 16,511 18,797 289 692 692 14-Bedroom#2 163 1,734 300 2,034 2,770 43 80 80 15-Master WIC 47 505 0 505 625 10 23 23 16-Master Bedroom 201 2,454 600 3,054 3,490 54 113 113 17-Master Bath 136 1,185 0 1,185 2,044 31 55 55 18-Bedroom#3 144 2,851 300 2,951 2,790 43 122 122 19-Foyer Open To Below 118 843 0 843 980 15 39 39 20-Bedroom#4 161 2,710 300 3,010 3,008 46 125 125 21Staim 50 154 0 154 473 7 7 7 22-Bati1 70 966 0 966 1260 19 45 45 23-Hall#3 28 427 0 427 262 4 20 20 24-Landing 60 527 0 527 571 9 24 24 25-Laundry 22 411 0 411 212 3 19 19 _ 26-1-19114_. __. . ... _._ . .. .. ... 33 .. ..444 0..... 444 312 5 20 .. .20 _. . Sum of room airflows may be greater than system airflow because system has mWtlpie zones. C:\Users\chrisw\Documents\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drive.rh9 Thursday,July 6, 2017, 8:28 AM Rhvac-Residential&Light Commercial HVAC Loads ,., Elite Software Development,Inc. 7lppolo Heating Inc. r - 71 Burnt Hills Drive- Queensbury,NY Schenectad ,NY 12306 Page 5 Duct Size Preview Room or Mid Maximum Rough. Design SP Duct Duct Ht9 Cig AU. Duct Source Duct Name Velodtyl _ Velocity Factor Ln OD Loss Velocity Length. .Flogi. . Flow Flow_ System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 598.6 108 82 1-5 Zone 2 2-Breakfast Nook Built-In 450 750 0.01 0.1 700.3 37 f 61 1-4 3-Kitchen Built-In 450 750 0.01 0.1 449.3 34 1 39 1-4 4-Great Room Built-In 450 750 0.01 0.1 519.4 78=1 102 1-6 5-Povder Room Built-In 450 750 0.01 0.1 308.9 8 27 1-4 "loset Built-In 450 750 0.01 0.1 99.7 2 9 1-4 7-Hall#1 Built-In 450 750 0.01 0.1 203.1 4r i 18 1-4 "tairs Built-In 450 750 0.01 0.1 3012 5 MENNj` 26 1-4 - . . 9-Office Built-In 460 750 0.01 0.1 601.8 45 99 1-6 TO-Foyer Built-in 460 750 0.07 0.1 388 17E ���i 34 1-411-Dining Room Built-In 450 750 0.01 0.1 497.3 43 F&&' 98 1-6 c 12-Mud Room Bulli-In 450 750 0.01 0.1 254.4 10 PA22 1-4 13•Hall#2 Built-In 450 750 0.01 0.1 196.8 3 :a,1'J 17 1-4 Zone 3 _ 14-Bedroam#2 Built-in 450 750 0.01 0.1 586.1 430'01 80 1-5 iSMasterwlc Built-In 450 750 0.01 0.1 266.6 10 j 23 1-4 16 Master Bedroom Built-In 450 750 0.01 0.1 648.1 54 I 113 2-4 17-Master Bath Built-In 450 750 0.01 0.1 626 31 1 55 1-4 18-Sedmorrl#3 Built-In 450 750 0.01 0.1 699.9 43 122 2-4 i&Foyer Open To Below Bulli-In 450 750 0.01 0.1 445.3 15 { 39 1-4 20-Bedroom#4 Built-In 450 750 0.01 0.1 457.9 46 1 125 2­5 21-Stairs Built-In 450 750 0.01 0.1 81.5 7 7 1-4 22-Bath 1 Built-In 450 750 0.01 01 510.1 19 2=1 45 1-4 23-Hall#3 Built-In 450 750 0.01 0.1 225.3 4 1 20 1-4 24-Landing Built-In 450 750 0.01 0.1 278.2 9 24 1-4 25-Laundry Built-In 450 750 0.01 0.1 216.9 3 19 1-4 26-Hell#4 Built-In 450 750 0.01 0.1 234.3 5 20 1-4 Other Ducts In System 1 Supply Main Trude Built-In 850 900 OB03 0.1 813.5 683 1,152 12x17 Summary System 1 Heating Flow: 683 Cooling Flow: 1152 CAUsers\chrisw\Dccuments\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drive.rh9 Thursday, July 6, 2017, 8:28 AM Rhvac-Residential 8 Light Commercial HVAC Loads Elite SoftwareDevelopment,Inc. Appolo Heating Inc. - 71 Burnt Hills Drive- Queensbury,NY Schenectad ,NY 12306 Pacle 6 Total Building Summary Loads_ NOT Area Sen Lat Sen Total escrl tion Quan Loss Gam_ _Gain Gad% Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 387.6 8,292 0 5,763 5,763 Front Door: Door-Front Door 20.4 239 0 80 80 Fire Rated: Door-Fire Rated 19 223 0 74 74 12E-Obw: Wall-Frame, R-19 insulation in 2 x 6 stud 1058.9 4,969 0 603 603 cavity, no board insulation, brick finish, wood studs 12F-Obw: Wall-Frame, R-21 insulation in 2 x 6 stud 2047.4 9,182 0 1,009 1,009 cavity, no board insulation, brick finish, wood studs 16A-38: Roof/Gelling-Under Attic with Insulation on Attic 1232.7 2,211 0 2,146 2,146 Floor(also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier,Any Roofing Material,Any Roof Color, R-38 insulation 21A-32: Floor-Basement, Concrete slab,any thickness, 2 1218 1,681 0 0 0 or more feet below grade, no insulation below Floor, any floor cover, shortest side of floor slab is 32'wide 19A-Ocp: Floor-Over enclosed crawl space, No insulation 2047.7 15,658 0 2,724 2,724 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 231.9 1,916 0 334 334 on exposed walls, sealed or vented space, passive, no Floor insulation, tile or vinyl Subtotals for structure: 44,371 0 12,733 12,733 People: 5 1,500 2,000 3,500 Equipment: 0 0 0 Lighting: 3000 10,230 10,230 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 210, Summer CFM: 210 15,723 4,220 2,734 6,954 Humidification (Winter)20.41 gallday: 7,484 0 0 0 AED Excursion: 0 0 47 47 Total Building Load Totals: 67,578 5,720 27,744 33,464 Check Figures ; Total Building Supply CFM: 1,152 CFM Per Square ft.: 0.319 Square ft. of Room Area: 3,615 Square ft. Per Ton: 1,296 Volume (113): 29,964. -$wilding Loads Total Heating Required Including Ventilation Air: 67,578 Btuh 67.578 MBH Total Sensible Gain: 27,744 Btuh 83 % Total Latent Gain: 5,720 Btuh 17 % Total Cooling Required Including Ventilation Air: 33,464 Btuh 2.79 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\chrisw\Documents\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drive.rh9 Thursday, July 6, 2017, 8:28 AM t2hvac-Residential&Light Cornmurcial HVAC Loads Elite Software Development,hrc.. Appolo Heating Inc 71 Burnt Hills Drive-Queensbury,NY- Schenectady, NY 12306 _Pa e34 System 1 Room Load Summary Hig Min `Run Run Cig Cig Min Act Room - Area Sens Htg Duct Duct Sens Lat Clg Sys. No Name SF Btuh CFM Size Vel Btuh Btuh _CFM CFM ---Zone 1--- 1 Basement 1,218 6,992 108 1-5 599 1,771 0 82 82 Zone 1 subtotal 1,218 6,992 108 1,771 0 82 82 ---Zone 2--- 2 Breakfast Nook 74 2,413 37 1-4 700 1,326 0 61 61 3 Kitchen 198 2,186 34 1-4 449 851 0 39 39 4 Great Room 311 5,099 78 1-6 519 2,213 0 102 102 5 Powder Room 26 546 8 1.4 309 585 0 27 27 6 Closet 14 105 2 1-4 100 189 0 9 9 7 Hall#1 32 246 4 1-4 203 385 0 18 18 8 Stairs 43 332 5 1-4 301 570 0 26 26 9 Office 164 2,904 45 1-6 502 2,138 0 99 99 10 Foyer 90 1,129 17 1.4 388 735 0 34 34 11 Dining Room 152 2,780 43 1-6 497 2,119 0 98 98 12 Mud Room 36 663 10 1-4 254 482 0 22 22 13 Hall#2 23 179 3 1.4 197 373 0 17 17 Zone 2 subtotal 1,164 18,582 286 11,965 0 551 551 ---Zone 3--- 14 Bedroom#2 163 2,770 43 1-5 586 1,734 300 80 80 15 Master WIC 47 625 10 1-4 267 505 0 23 23 16 Master Bedroom 201 3,490 54 2-4 648 2,454 600 113 113 17 Master Bath 136 2,044 31 1-4 626 1,185 0 55 55 18 Bedroom#3 144 2,790 43 2-4 700 2,651 300 122 122 19 Foyer Open To 118 980 15 1-4 445 843 0 39 39 Below 20 Bedroom#4 161 3,008 46 2-5 458 2,710 300 125 125 21 Stairs 50 473 7 1-4 81 154 0 7 7 22 Bath 1 70 1,260 19 1.4 510 966 0 45 45 23 Hall#3 28 262 4 1.4 225 427 0 20 20 24 Landing 60 571 9 1-4 278 527 0 24 24 25 Laundry 22 212 3 1-4 217 411 0 19 19 26 Hall#4 33 312 5 1-4 234 444 0 20 20 Zone 3 subtotal 1,233 18,797 289 15,011 1,500 692 692 Ventilation 15,723 2,734 4,220 Humidification 7,484 _ System 1 total 3,615 67,578 683 _ 27,744 5,720 1,152 1,152 System 1 Main Trunk Size: 12x17 in. Velocity: 814 ft./min Loss per 100 ft.: 0.094 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average Load Procedure+ Excursion"method. :Cooling System_SummaH - Cooling Sensible/Latent Sensible Latent Totai, a aµ mss„ Tons Split__ 6tuh Btuhtu"7 Net Required 2.79 83% 1 17% 27,744 5,720 33,464 Actual: 3.33 75% l25°% 30,000 10,000 40,000 Equipment Data 4 ;.. Floating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH090XP60C-* 13ACXN042-230-*" CAUsers\chrisw\Documents\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drive.rh9 Thursday, July 6, 2017, 8:28 AM Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc. AA""o Heating Inc 71 Burnt Hills Drive Queensbury,:NY $chenectad ,.NY 12306 Page 35 System 1 Room Load Summary (contV) E 217JentiData Indoor Model: C35-49C"+TDR Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 86,000 Btuh 40,000 Btuh Sensible Capacity: n/a 30,000 Btuh Latent Capacity: n/a 10,000 Btuh AHRI Reference No.: n/a 8630634 C:\Users\chrisw\Documents\Elite Software\Rhvac 9 Projects\71 Burnt Hills Drive.rh9 Thursday, July 6, 2017, 8:28 AM REScheck Software Version 4.6.2 Compliance Certificate O N nU w Project PC552 - Aster c _J o 00 M ';r Energy Code: 2015 IECC 0) •'-' V Location: Warren County, New York.---- -- -------- V G --I a) CD Construction Type: Single-family \� = &Project Type: New Construction ^i L-J Q, tII Conditioned Floor Area: 2,299 ft2O Glazing Area 15% I �UL 12 2017 � Climate Zone: 6 (8499 HDD) U I O = N Permit Date: 5 July, 2017OWN � � ! pp f/1 =OF QUEENSc'.;; Permit Number: BUI!L7)NG$ (�Q'�c ( 4) N Construction Site: Owner/Agent: M. Designer/Contractor: CD 00 V m Q 71 Burnt Hills Drive Michaels Group Homes, LLC O .— LL Queensbury, NY 1 Marions Way CO) fn Mechanicville, NY Compliance: Passes using UA trade-off Compliance: 0.3%Better Than Code Maximum UA: 314 Your UA: 313 The%Better or worse Than Code index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Assembly Gross Area Cavity Cont. or U-Factor UA Foundation Wall:Solid Concrete or Masonry 1.117 0.0 19.0 0.039 43 Wall height:7.6' Depth below grade:6.6' Insulation depth:7.6' 1x 5030 Sliding Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.300 5 2x Std Basement Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 4 0.300 1 1st Floor Walls:Wood Frame, 24" o.c. 1,323 21.0 0.0 0.056 60 Ix Home Office(AU):Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.300 11 Foyer#1: Solid 21 0.170 4 1x Dining (AU):Vinyl/Fiberglass Frame:Double Pane with Low-E 35 0.300 11 Mud#20:Solid 19 0.170 3 2x Breakfast(B):Vinyl/Fiberglass Frame:Double Pane with Low-E 19 0.300 6 Breakfast#7: Glass 40 0.300 12 3x Great Room (E): Vinyl/Fiberglass Frame:Double Pane with Low-E 43 0.300 13 Ix Great Room (R):Vinyl/Fiberglass Frame:Double Pane with Low-E 27 0.300 8 Ix Powder(AM):Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.300 2 2nd Floor Walls:Wood Frame, 24" o.c. 1,160 21.0 0.0 0.056 57 Ix Bed #3 (G):Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.300 10 Project Title: PC552-Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 1 of10 Gross Area Assembly or Cavity Cont. U-Factor UA 1x Foyer(BB):Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.300 5 1x Bed#4 (G):Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.300 10 Ix Bath (AM):Vinyl/Fiberglass Frame:Double Pane with Low-E 7 0.300 2 Ix Bed#2 (U):Vinyl/Fiberglass Frame:Double Pane with Low-E 17 0.300 5 1x Master Bed (G):Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.300 10 1x Master Bath (BM):Vinyl/Fiberglass Frame:Double Pane with Low-E B 0.300 2 Ceiling: Raised or Energy Truss 1,293 38.0 0.0 0.025 32 Plant Shelf:All-Wood Joist/rruss:Over Outside Air 28 30.0 0.0 0.033 1 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in RE11Scheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. NuOa s� J �Iv►�11rw� r ���S r•44►+'T ��J.�.tL��l Name-Ti[e Signat A c� c A�0StillJa��/ Project Title: PC552 -Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the ,gy building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1. Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable 14 dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr— ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: []Not Observable Manual J or other methods Btu/hr— Btu/hr_ approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 3 of 10 Section Plans Verified Field Verified # Foundation Inspection &Re .ID Value Value Complies? Comments/Assumptions 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F0411 insulation R-value.Where interior R- R- []Does Not table for values. insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection.Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO511 insulation installed per ❑Does Not $, manufacturer's instructions. []Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft It ❑Complies See the Envelope Assemblies [F0611 insulation depth of burial or ❑Does Not table for values. 9 distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO1112 to protect exposed exterior ❑Does Not 14 insulation and extends a ❑Not Observable minimum of 6 in.below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO1212 controls installed. ❑Does Not j❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 IMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PC552-Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 4 of 10 Section Plans Verified Field Verified # Framing/Rough-in inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 El Does Not table for values. [FR111 ❑Not Observable 0 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR211 303.1.3 U-factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not $, instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2011 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 []Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated>=R-8 where duct is ❑Does Not Q >=3 inches in diameter and >_ ❑Not Observable R-6 where< 3 inches.Supply and return ducts in other portions of ❑Not Applicable the building insulated >=R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR1513 ducts or plenums. ❑Does Not [-]Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to alk- ❑Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC []Complies [FR24]1 piping. ❑Does Not []Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R-_ R-_ ❑Complies [FR1812 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 i Low Impact(Ter 3) Project Title: PC552 -Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 5 of10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552-Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions &Re .ID 303.1 All installed insulation is labeled ❑Complies [IN13]' or the installed R-values ❑Does Not 0 provided. ❑Not Observable ❑Nat Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN111 ❑ Steel ❑ Steel ❑Not Observable to ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ?❑Does Not [IN211 in substantial contact with the underside of the subfloor, or floor '![]Not Observable framing cavity insulation is in ?❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R-_ R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1h of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [IN311 exterior,the exterior insulation ❑Not Observable 0 requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per •4;❑Complies [IN411 manufacturer's instructions. ❑Does Not [-]Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 'High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552-Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 7 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & R .11) 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2• ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [FI111 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every 300 W. ❑Not Observable ❑Not Applicable 402,2.3 Vented attics with air permeable ❑Complies [F12212 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R-_ R-_ ❑Complies (FI311 insulation ;-R-value of the ❑Does Not adjacent assembly. ❑Not Observable []Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50=_ ACH 50 =_ ❑Complies [FI1711 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 dm/100 dm/100 ❑Complies (F1411 dm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air []Not Observable handler @ 25 Pa.For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to dm/100 dm/100 ❑Complies [F12711 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstrudion test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable []Not Applicable 403.1.1 Programmable thermostats ❑Complies (FI 912 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. []Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. ❑Does Not ❑Not Observable []Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI1112 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 low Impact(Tier 3) Project Title: PC552 -Aster Report date: 07/05/17 Data filename: FAShare\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.lD 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and airflow limits, ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI2612 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F[28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems []Complies [FI29]2 comply with IEEE 515.1 or UL []Does Not 515. Controls automatically []Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies IF13012 have recirculation pumps that []Does Not pump waterfrom a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI3112 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat [:]Not Observable recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable Does not apply to low-voltage lighting. ❑No[Applicable _ _ _ 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not Q� [-]Not Observable ❑Not Applicable 1 High Impact(Tier 11 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 9 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 401.3 Compliance certificate posted. ❑Complies [1`I71' ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for i,❑Complies [91813mechanical and water heating ❑Does Not systems have been provided. =; -',❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PC552 -Aster Report date: 07/05/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\71 Burnt Hills Drive.rck Page 10 of 10 �( 2015 IECC Energy j Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments LO°LLS � {{ /: tl3atl yflo ON' 1 I y ECEPWEoi� W t � `o JUL 1 2 2017 ! N 01=QUEENSBURY 1 UILDING& CODES j cm Nt LO F o � y Z L 14 I C`] U U OQ I O r" N J fh t` r I HpVF.PER SDNAL IY MEASURED THE DISTANCE 11 S TO THE FROM THE PROP OR SIGN ) w ��TA RTY LINE ^ K PROPO ST CTUREIS) _ lo' D E m O SI NATU 3 W ZD �a 4- �6 66. 6L ,09'96 00' 055F/ 3 °LS,LE°S8 S aAIdQ S'IZIH LLNZI. 308.8-1-80 RC-000417-2017 Michael's Group Homes LLC 71 Burnt Hills Drive, Lot 36 SFD 2299 s.f., Garage 440 s.f.