Loading...
2012-339 (2)GENERAL NOTES: DESIGNERS NOTES: 1) ALL EMERGENCY ESCAPE FOR BEDROOMS AND HABITABLE SPACE REQUIRED AS FOLLOWS: t DO NOT SCALE THESE DRAWINGS, THEY MAY NOT BE TO AN EXACT SCALE, - A CLEAR OPENING OF 5.7 SQ.FT. ABOVE OR BELOW GRADE LEVEL USE ONLY DIMENSIONS GIVEN. - A CLEAR OPENING OF 5.0 SQ.FT. AT GRADE LEVEL : CONCEPTS & DESIGNS WILL NOT BE RESPONSIBLE FOR ANY STRUCTURAL DEFECTS - A MINIMUM HEIGHT OF 24" FROM THE FAILURE TO FOLLOW PLANS AND DETAILS. - A MINIMUM WIDTH OF 20" 2) SAFETY GLAZING REQUIRED BY CODE AT THE FOLLOWING LOCATIONS: DIMENSIONAL MATERIALS & FRAMING NOTES: - EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ.F.T - BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR - ALL DIMENSIONS SHOWN ARE FROM FRAME TO FRAME. - ONE OR MORE WALKING SURFACES WITH IN 36" HORIZONTALLY OF THE GLAZING - ALL EXTERIOR WALLS ARE 26 OR 5.1/2" UNLESS OTHERWISE NOTED. - THE EDGE GREATER THAN 36" ABOVE THE FLOOR - ALL INTERIOR WALLS ARE 20 OR 3,1/2" UNLESS OTHERWISE NOTED. - GLAZING WITHIN 60" OF A POOL OR SPA - ALL EXTAEADERS 2-2x10 S.P.F.UNLESS OTHERWISE NOTED. - GLAZING ADJOININGS STAIRS WITHIN 60" OF THE BOTTOM TREAD - ALL DIMENSIONAL MATERIALS ARE SPF12 OR BETTER, 3) N.Y. STATE ENERGY CODE COMPLIANCE PROGRAM: - THIS BUILDING DESIGN HAS BEEN ENTERED IN THE RESIDENTAL MEC -CHECK SOFTWARE PROGRAM AND A PASSING COMPLIANCE FORM AND INSPECTORS CHECKLIST HAVE BEEN SUBMITTED WITH THE PERMIT APPLICATION, 4) SEE FOUNDATION PLAN AND DETAIL SHEET FOR DAMPROOFING, WATERPROOFING & FOUNDATION WALL REQUIREMENTS. 5) GRADE AROUND FOUNDATION MUST DROP 6" IN 10' PITCHING AWAY FROM FOUNDATION REQUIRED PER CODE, 6) A LANDING MUST BE PROVIDED ON EACH SIDE OF AN EXTERIOR DOOR AT A MIN. 36"wX 36"h (SEE DETAIL THIS SHEET) 7) PROVIDE AT ALL EAVES ICE AND WATER SHEILD @ MIN. 24" HORIZONTALLY FROM INSIDE EXTERIOR WALL REQUIRED BY CODE WITH INSPECTION PRIOR TO SHINGLING. 8) STAIRWAY REQUIREMENTS: - A 6'-8" MIN. HEADROOM CLEARANCE REQUIRED FOR ALL STAIRS PER CODE - ALL STAIRWAYS HAVE A MIN. REQUIRED WIDTH OF 36" PER CODE - SEE PLANS & SECTIONS FOR RISE & RUNS AND ANY DETAILS REGARDING STAIRS a� - STAIRWELL WINDER TREADS REQUIRE A MIN. DEPTH OF 6" - OPEN RISERS NO LONGER ALLOWED FOR STAIRS OVER 30" IN HEIGHT UNLESS IS 4" OR LESS - SPIRAL STAIRS ARE NOT ALLOWED TO BE THE ONLY MEANS OF EXIT FROM A STORY. 9) HANDRAIL REQUIREMENTS: - HANDRAILS REQUIRED ON ALL STAIRS OF TWO OR MORE RISERS - HANDRAILS REQUIRED ON BOTH SIDES IF OPEN AND RISE ARE MORE THAN 30" - HANDRAILS MUST BE BETWEEN 34" AND 38' IN HEIGHT AN MUST TERMINATE AT WALLS - HANDRAILS MUST BE CONTINUOUS FROM BOTTOM STEP TO TOP STP - SEE CROSS SECTION FOR ANY OTHER DETAILS ON HANDRAILS. 10) GUARDRAIL REQUIREMENTS: - REQUIRED ON ALL SURFACES WHICH ARE RAISED MORE THAN 30" ABOVE OR BELOW GRADE. - GUARDRAIL MINIMUM HEIGHT OF 30" FOR LANDINGS, PORCHES AND DECKS. - GUARDRAIL MINIMUM HEIGHT FOR STAIRS 340 AND NO MORE THAN 6" ON STAIRS WHERE RISER, TREAD AND BOTTOM RAIL MEET (EX. A 6" BALL SHOULD NOT BE ABLE TO PASS THROUGH) - GUARDRAILS NO MORE THAN 4" BETWEEN BALUSTERS OR HORIZONTAL RAILS - GUARDRAILS REQUIRED ON BASEMENT STAIRS. 11) ALL HALLWAYS MUST BE A MIN. WIDTH OF 36" 12) SMOKE DETECTOR REQUIREMENTS: - SMOKE DETECTORS MUST BE HARDWIRED W/ BATTERY BACKUP - SMOKE DETECTOR ON EVERY LEVEL - SMOKE DETECTORS IN EVERY BEDROOM 13) GARAGE FIRE SEPERATION CODES: - THE DWELLING GARAGE SEPERATION CODES REQUIRE 5/8' TYPE"X" FIRED RATED GYPSUM WALL BROAD ON BOTH SIDES OF THE WALL ADDRESSING THE DWELLING UNIT AND THE ENTRE GARAGE CEILING W/NO PENETRATIONS - THE DOOR WHICH SEPERATES THE DWELLING AND GARAGE MUST BE OF MIIi, 3/4 HOUR ARE RATED AND ASSEMBLY UNIT. 14) FIRE STOPPING REQUIREMENTS: - FIBERGLASS INSULATION MAY BE USED IF IT FILLS THE WIDTH OF TH CAVTY AND EXTENDS A MINIMUM 16" FROM THE TOP OR BOTTOM PLATE . - FIRE STOPPING REQUIRED 10' VERTICAL AND HORIZONTAL. - ALL PENETRATIONS MUST BE STUFFED OR SEALED, FIBERGLASS INSULATION IS ALLOWED 15) NOTCHING AND DRILLING FOR EXTERIOR AND LOAD BEARING WALLS: - LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY METAL TIE .054 THICK BY 1.1/2" WIDE WITH (8)160 NAILS EACH SIDE EXCEPT EXTERIOR WALLS COVERED WITH PLYWOOD - HOLES GREATER THAN 1.1/20 REQUIRES DOUBLE STUDS - NOTCHES NO MORE THAN 35% OF STUD DEPTH, 16) PLUMBING TESTING : ALL DRAINS, VENTS, AND SUPPLY PIPING MUST BE TESTED TO THE FOLLOWING CRITERIA: - WATER HEAD TEST 10' ABOVE HIGHEST CONNECTION - 5 PSI FOR 15 MINUTES 17) HEATING AND VENTILATION DUCTS MUST BE SECURED AND SEALED IN ACCORDANCE WITH NYS ENERGY CODE. 18) BUILDER MUST PROVIDE A 30"x 22"x 30'H ATTIC ACCESS IN A HALLWAY OR A READILY ACCESSIBLE AREA, SEE PLAN FOR LOCATION 19) COMBUSTION AIR REQUIREMENTS: - IF THERE IS NO COMBUSTION AIR SUPPLIED TO GAS APPLIANCES, INSTALLER MUST CERTIFY BASEMENT OR ROOM HAS PROPER AMOUNT OF COMBUSTION AIR PER CODE AT FINAL INSPECTION 20) THE STREET ADDRESS MUST BE POSTED ON BUILDING AND/OR VISIBLE FROM THE STREET, IF LONG DRIVEWAY ADDRESS MUST BE POSTED ON MAILBOX OR POST AT THE ENTRANCE TO THE DRIVEWAY ON THE SAME SIDE OF THE STREET. TOWN OF QUEENSBURY BUILDING & CO ES DEPT.'' Reviewed y: Date: Z_ DESIGN LOAD CRITERIA LOADS USED IN THE DESIGN OF THE STRUCTURE "GROUND SNOW LOAD OF 70 PSF 2. WIND LOAD OF 90 MPH 3. 2ND FLOOR LOADING - 40 LBS PER/SQ.FT. - LIVE LOAD: 40 LBS PER/SQ.FT, - DEAD LOAD: 10 LBS PER/SQ.FT. 4.) IST FLOOR LOADING - 50 LBS PER/SQ.FT. - LIVE LOAD: 40 LBS PER/SQ.FT. - DEAD LOAD: 10 LBS PER/SQ.FT. NOTICE FOAM INSULATION MUST BE COVERED BY A 15 MINUTE THERMAL BARRIER NOTICE KRAFT P ° -It N &MON MUST BE OOYERED 40*MWUMBLE BARRIER NOTES: TOWN '" BUILD. ,id on our lima, n Mce an ur comment rued as Ming the pian: ; are in %Imphance with ire , es of cork State. TOWN nr',tjEENSBURY BUId_DIN4 CEPARTMENT �psed 4n ed a pince with our cmttsh"dmniontatecocnosmtrueiad as tnd�ting the plans end tpacifications are in fuU epmphar m with the Building Codes of Now, Ywk State, NOTICE: Smoke detectors are required In bedroom adjacent to bedrooms and on each floe level including cellar or basemen All smoke detectors & carbon monoxir�2 detectors shall be Interconnnected wig battery backup and located on all level Carbon monoxide detectors outside sleer5ing areas and NATURAL LIGHT, VENTILATION & EMERGENCY EGRFjSS REQUIREMENTS HAB. ROOM REQ. LIGHT ACTUAL REQ. VENT ACTUAL SQ/[ -T REMARKS ROOM AREA 8% OF ROOM UGHT 4% OF ROOM VENT OPENING FOR HEIGHT r IN SQ/FT AREA SQ/FT AREA SQ/FT EGRESS 100 178 14.24 24.16 7.12 11.96 5.98 12.08 101 223 17.84 24.16 8.92 11.96 5.98 61" 102 110 8.80 11.98 4.40 5.98 5.98 103 110 8.80 11.98 4.40 5.98 5.98 2.69 104 152 12.16 24.16 6.08 11.96 5.98 37" 2.69 . , I 13.1/2 2.69 .47 TEMPERED v BALUSTERS MUST BE NO MORE THAN 4" BETWEEN BALUSTERS OR HORIZONTAL RAILS. (4" SPHERE SHOULD BE UNABLE TO PASS THROUGH OPENING) 6" SPHERE UNABLE TO PASS THROUGH OPENING NOTES: - GUARDRAILS CANNOT CONSIST OF HORIZONTAL RAILS OR ANY ORNAMENTAL PATTERN THAT CREATES A LADDER EFFECT - ALL HANDRAILS TO BE CONTINUOUS FOR FULL LENGTH OF STAIRS TERMINATING AT WALL OR NEWEL POST. HANDRAIL TO BE 1.1/4"MIN./2" MAX. W/SMOOTH SURFACE W/NO SHARP EDGES WINDOW & DOOR SCHEDULE QTY. CALL # WINDOW MODEL # R.O. R.O. CLEAR OPG. CODE ACTUAL GLASS U -FACTOR DESCRIPTIONS MANUFACTURER WIDTH HEIGHT r EGRESS EGRESS SQ.FT. _t 6 MODERN VIEW 30410 38" 61" 5.98 SQ.FT. 24"MIN. 25.1/2" 12.08 .47 DOUBLE HUNG 1 I �- 30410-2 75.5/8" 61" 5.98 SQ.FT. 24"MIN, 25.1/2" 24.16 .47 " 2 26210 32" 37" 2.69 1 3.1/2" 2.69 .47 26210 32" 37" 2.69 . , I 13.1/2 2.69 .47 TEMPERED v IU'< (A o n 1 6 -PANEL 38.3/4" 82.3/4" 20 SQ.FT. - - - .069 BENCHMARK 1 FRE DR 36.3/4" 81.3/4" 20 SQ.FT. - - - .069 BENCHMARK 1 6068OX 72" 80" 20 SQ.FT. - - I - 40 .47 MODERN VIEW i 15' r MIN. 4" MIN. Y MIN. MIN. Me M N 4.1 1V1119. VLLARAN VE @ LAVATORIES 21' MIN.CLEARANCE @ WC AND TUBS MINIMUM FICTURE CLEARANCES 4 MIN. 15" MIN. HA �N'DRAIL DETAIL AND NOTES: rHOWER 14" CLEARANCE IN FRONT OF OPENING 24" 30" MIN. Z 0 IN i--- � Q o o C= 1 r _t O Q)cn I �- > id . , I M IU'< (A o IN ccr10 I QzN 0�-qcc 10 00 0 O� Of a ENGINEERS STAMP: DATE: 04/20/03 SHEET#: 1� CP - I l 1 r _t ccr10 I QzN 0�-qcc 10 00 0 O� Of a ENGINEERS STAMP: DATE: 04/20/03 SHEET#: 1� CP - I I m 3 o m Be R 7w 1 k m 0 O m f- ry C/7 W W CDw o � z < W J Q Q U (n C) ENGINEERS STAMP: JOB#- 101705_ DATE: 10/04/05 SHEET#: A 07 ' Io — ilw � tri 45 `\1 4 M 1 y�I u, -0e, 4c c� 1 C t1 t} '- 1 = Nv- I P —_— Io — ilw � tri 45 `\1 4 M 1 y�I u, -0e, 4c c� 1 C t1 t} '- 3.1 INSULATION: N.Y. STATE REQUIRES AS FOLLOWS: — FLAT CEILING: 12" KRAFT INSULATION R-38 W/PROPER VENT — EXTERIOR WALLS: 6" KRAFT INSULATION R-19 — CANTILEVER: 9" KRAFT INSULATION R-30 — FOUNDATION WALLS: UNFACED 3.1/2" R-11 rLD'-o1\ 1-,,, ?., III ICE k WATER SHIELD MIN. EXPOSURE 0 EACH PAVE 2 0" , f I — 2-1.3/4"x11.7/8' MICROLAM HEADER GARAGE ,_PITCH SLAB 1/8" PER/FT GYPSUM WALL )CEILING k GYPSUM WALL ® WALLS 4" WK. SLAB w. I MR Will , Will Off Mll No �, NO 22 1 L L lommol-sm PORCH ROOF: 2x6 RAFTERS 0 16"O.C. W/1/2"OSB SHEATF 2x6 CEILING JOISTS 016"O.C., 15# FELT PAP ICE & WATER SHIELD (AT EAVE & VALLEYS 25YR. ARCHITECTURAL SHINGLES, PROPER VENT 0 EAVES ONLY & RIDGE VENT,VINYL S (SEE OWNER FOR COLOR) ,3 v T VVIY1.. .]LMp 16'X8` CONT.CONC.F:G. ur'l� � M S SECS IL MN ° FA —A o ROOF: MAIN ROOF: 0 N.Y. STATE CERTIFIED ROOF TRUSSES 0 24"O.C.) SEE MANUFACTURERS CERTIFIED DRAWING FOR DETAILS) ROOF TRUSSES 0 24" O.C.W/1/2"OSB SHEATHING, 1/2' GYPSUM WALL, 15# FELT PAPER, ICE & WATER SHIELD (AT EAVE & VALLEYS ONLY), 25YR. ARCHITECTURAL SHINGLES, PROPER VENT 0 EAVES ONLY m & RIDGE VENT. (SEE OWNER FOR COLOR) EAVE & RAKE: 2x6 SUBFASCIA W/ALUM. FASCIA, DRIP EDGE & VINYL SOFFIT VENT EAVE & RAKE OVERHANG= 12" ICE AND WATER SHEILD REQUIRED AT ALL EAVES MIN, 24" HORIZ FROM INSDIE OF EXTERIOR WALL AND SHALL BE INSPECTED 2nd FLOOR WALLS: CL - 2x6 OR 5.1/2" EXTERIOR WALLS 0 16"O.C. W/7/16" OSB SHEATHING, 1/2" GYPSUM WALL BRD., TYVEK VAPOR BARRIER 4" T.W.VINYL �� U SIDING & CORNER BRDS. (SEE OWNER FOR COLOR) 2nd FLOOR: w 0 2x10 FLOOR JOISTS 0 16"O.C. W/3/4" T&G OSB PLYWOOD SHEATHING GLUED & SCREWED, 1st FLOOR WALLS: Iw 2x6 OR 5.1/2" EXTERIOR WALLS 0 16"O.C. W/7/16" OSB SHEATHING, 1/2 GYPSUM WALL BRD., TYVEK VAPOR BARRIER 4" T.W.VINYL SIDING & CRNR.BRDS. (SEE OWNER FOR COLOR) W Cy 1 st FLOOR: 2x10 FLOOR JOISTS 0 16"O.C. W/3/4" T &G OSB PLYWOOD SHEATHING 0 GLUED & SCREWED. — +' BASEMENT FLOOR WALLS: cQ)Q II ME 2x4 OR 3.1/2" EXTERIOR WALLS 0 24"O.C. W/3.1/2" cf) _ UNPAGED INSULATION W/PLASTC O•• FOUNDATION:m 8" CONCRETE _ WALL W/2x6 P.T. SILL PLA—;-_— SILL SEAL W J T.O.W.= 8'-0" 16"0' CONT. CONC. FTG.J U < T.O.F.= 0'-0" ~ SEE FOUNDATION DETAILS ON SHEET "D-1" I -- DESIGN LOAD CR TR'A - GROUND SNOW LOAD 70 _BS. P--Rj'SQ.FT. - WIND LOAD BASED ON 90 MPH RANG ROOF LOADING: 70 LBS, PER/SQ.FT. TOP CHORD LIVE I OAD: 50 LBS. PER/SQ.FT. TOP CHORD DEAD LOAD: 10 LES. PER; SO.=T. BOTTOM CHORD DEAD LOAD: 10 LBS. PEP;: SQ.FT. FLOOR LOADING: 2ND FLOOR 50 LBS. PER/SQ.FT. - LIVE LOAD: 40 LBS. PER/SQ.FT. - DEAD LOAD: 10 LBS. PER/SQ.FT. FLOOR LOADING: 1ST FLOOR 50 LBS. PER/SQ.FT. - LIVE LOAD: 40 LBS. PER/SQ.FT. - DEAD LOAD: 10 LBS. PER/SQ.=T. M ENGINEERS STAMP: JOB# 101005 DATE: 060103 SHEET#: S-1 co CO C\2 up �cc T -a Lo N 03 � o W m NOTE: FIELD APPLIED GIRDER BLOCKING AS REQUIRED 2 a FOUNDATION WALL W = WALL WIDTH H = WALL HIEGHT MINUS 2" G = GIRDER WIDTH +2" BEAM PKT . DETA I L 2 FN SECT I ON SCALE = NONE 2x4 EXT . WALL CONST . W/ 7/ 16"OSB SHTH . & P.T. BOTTOM PLATE 1/2"x8" ANCHOR BOLTS @ 48' b .0 . 4" RE I NFORCED CONIC .SLAB @ 1"M IN .BELOW SURFACE & REBAR (RE I NFORC I NG AS RE go, 16" @ 24' bO C . IRED BY STATE CODE) FINISH GRADE 8" MIN. BELOW T .0 .W . & GRADE MUST DROP 6" IN 10 'AWAY FROM STRUCTURE AS PER CODE 8" POURED CONCRETE FROST WALL PROV I DE B I TUM I NOUS TAR DAMP PROOF I NG I S ALLOWED BUT MUST BE DRY FOR INSPECT ION BEFORE BACKF ILL BEG INS SANDY SOIL BACK FILL ADDRESSING FOUNDATION WALL AS REQUIRED SCALE= NONE PROV IDE 12" LONG#4 VERT ICAL REBAR P INS FOR FOR IZONTAL SFEAR @ 48" 0 .0 . TYP .) 16"x8" CONT .CONCRETE FTG. W/2-#4 CONT AEBARS T .0 .W . (TOP OF WALL) 4 '-4" T.O.F. (TOP OF FTG.) 01-011 6" COMPACTED GRAVEL W/ 6M I L POLY. VABPOR BARR I ER AS DETERM I NED BY LOCAL CODES 20 EXT, WALL CONST, W/ 7/16° WALL SHTH. & P.T. BOTTOM PLATE 1/2°x8" ANCHOR BOLTS @ 48"O.C. 4"CONC.SLAB F IN ISH GRADE 8" M I N . BELOW T.0 .W W. & GRADE MUST DROP 6" IN 10 'AWAY FROM STRUCTURE AS PER CODE 8" POURED CONCRETE FROST WALL PROVIDE B ITUM I NOUS TAR DAMP PROOFING IS ALLOWED BUT MUST BE DRY FOR INSPECTION BEFORE BACKFILL BEGINS SANDY SOIL BACK FILL ADDRESSING FOUNDATION WALL AS REQUIRED PROVIDE 12" LONG #4 VERTICAL REBAR PINS FOR HORIZONTAL SEAR @ 48" 0 .0 . (TYP.) 16"x8" CONT .CONCRETE FTG. W/2-#4 CONT.REBARS T .0 .W . (TOP OF WALL ) 0 '-4" T.O.F. (TOP OF FTG . -41-411 6" COMPACTED GRAVEL W/ 6M I L POLY. VABPOR BARR I ER AS DETERM INED BY LOCAL CODES 104 I SCALE = NONE 3' FND-P 2x6 WALL CONSTRUCTION 016° O.C. W/1/16" WALL SHEATHING (TYP.) 1/2'xT ANCHOR BOLTS 0 4TO.C. W/ 26 P.T. SILL PATE & SILL SEAL SECT ION SCALE = NONE F IN ISH GRADE 8" M I N . BELOW T .0 .W . & GRADE MUST DROP 6" IN 10 'AWAY FROM STRUCTURE AS PER CODE 8" POURED CONCRETE FROST WALL 20 WALL CONSTRUCT ION @ M I N . 24" O.C. W/ 3.1/2" F.G. I NSULAT ION & 1/2" GYPSUM WALL BOARD PROVIDE BITUMINOUS TAR DAMP PROOFING IS ALLOWED BUT MUST BE DRY FOR INSPECT ION BEFORE BACKFILL BEGINS SANDY SOIL BACK FILL ADDRESSING FOUNDATION WALL AS REQUIRED PROV I DE 12" #4 VERT I CAL REBAR P I NS FOR HOR I ZONTAL SHEAR @ 48" 0 .0 . (TYP .) 16"x8" CONT .CONCRETE FTG. W/2-#4 CONT .REBARS T .0 .W . (TOP OF WALL) 8 '-0" T.O.F. TOP OF FTG .) T.O.S. ((TOP OF SLAB ) 0 '-4" 01-011 CZ ' m i U i I W �Oj LTJ i � z cn iQ I77 1 - +-' M ' m ), Li U-) Q LO NcqCO �ZN � U)LO o ENGINEERS STAMP: DATE: 03/10/04 SKEET#: D f -► LO NcqCO �ZN � U)LO o ENGINEERS STAMP: DATE: 03/10/04 SKEET#: D