Loading...
2005-895 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20050895 Date Issued: Friday, May 19, 2006 This is to certify that work requested to be done as shown by Permit Number P20050895 has been completed. Tax Map Number. 523400-308-008-0002-030-000-0000 Location: 20 DAWN Rd Owner. CLUTE ENTERPRISES Applicant: CLUTE ENTERPRISES This structure maybe occupied as a: Single Family Dwelling By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050895 Application Number: A20050895 Tax Map No: 523400-308-008-0002-030-000-0000 Permission is hereby granted to: CLUTE ENTERPRISES For property located at: 20 DAWN Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and' compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: CLUTE ENTERPRISES 13 DAWN Rd Single Family Dwelling $100,000.00 QUEENSBURY, NY 12804-0000 Total Value $100,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-895 1040 SQ FT SINGLE FAMILY DWELLING $124.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, December 01, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at o of Q e ns�74,tday, December 01, 2005 1� SIGNED BY `�� for the Town of Queerisbury. Director of Building&Code"Enforcement Check Residential Plan Review: One&Two Family Dwellings yhN/N/A (2)Full sets of plans +� Over 1,500 sq. $.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations. r } Window Schedule With Glass Size ' ; Door Schedule/Main Entrance 36 Door Emergency Escape Or Bedrooms and Habitable Space 1 Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. �+ 24"(h)x 20"(w)min. 44"Max.Heigbt above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK A?ampproofmg/Waterproofing Materials On Plans f Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where ' -Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors ti E � Stairway Headroom 6' 8'All Stairs 36"Width tair Run and Rise T Winder Run and Rise (✓ Spiral Not Allowed From 2° Story Smoke Detectors Battery Backup and Proper Location �. ) Bathroom Fixtures Proper Clearance i J Hall Width,36"min. ' ? Handrails More Than One Riser On Open Sides d Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. 9 Safety Glazing Notes For Required Areas V,96age Fire Separation F Gage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Job Site Address: ten' Date,. Owner; Application No. Pile No, �� Building Permit --Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements CEW ED Habitable Areaof Req,LigYlt Actual Req,Vent Actual Sq.Ft, Remarlcs Room Room 8%of Room Light 4°/a of Room Vent Opening for 1 NOV 1 5 2Q�5 in. . * Area Square Area Square Egress Square Footage Footage 7' N OF Feet QDE6/aSB(RYN oG oE Y. 3S • I i r • I L:1Sueliemingway�8uilding,PetmitFOItMS�tVat.L{ght Ventil.Caiculation,Sheet.doc WINDOW SCHEDULE RECEIVED to Address: c \-�- Date: ® �� �a-� v 1 5 2005 Job e I _R5 T Owner: � �� Appiica�ion No. TOM, pF QUEENSBURIf s III DING AND CODE Window Window Window Unit or Rough Rough SQ.FT. SQ,FT SQ.FT, Clear Clear spec I Hardware Number or Manufaturor ModelRype Stock Openin Opening GlassNis Egress/Cle Opening Opening or Instructions Letter on Named Numbe g Height Ible Vent ar Width In Height Plan Call Width Light Opening Inches In inches ` ``1 size i • I i Example Entry A Andersen Narrollne 3062 3' 2 6'5 '/s 15.30 8.36 6.01 34 2416/35" Tempered Double 1/3" 11/16 Glazing Hung—L I C,.\Documenu and SeWnSaut.UZZl Sttdugs\Temp\Window Schedule.doe Permit No. Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@queensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans sublect.to review before issuance of a valid permit for construction Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. r Applicant/Builder. _ C_ Owner: r Address: Gd _L-jR\ Xe, Awe Address: Home Phone: ,? 'yy�Z Home Phone: Email Address: l C. � C� c'Ac� -� �'�-� Email Address: Cell Phone: 3(�, l , Cell Phone: FAX Phone: -? FAX Phone: Person responsible for supervision of work with respect to building and codes complianc �opG�U�F Name: Address: Phone Location of proposed construction: Lot No. Legal Address: 7 Tax Map Number: 304A --3 ; Subdivision Name: Estimated Cost of Construction: $ X C) Proposed construction is for: Residential Use _Commercial Use Name of Business: If proposed construction is an addition,what will use of new addition be? New Addition Alteration Proposed Construction 1,1 Floor 2^d floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height Ft.&in., Single-Family Dwelling Q C) Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: - Attached Garage 1,' 2, 3 Type of Heating System: Electric, Oil, as, Wood, orced Hot Air, aseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes �No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of O pa cy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director uilding nd Cod , an As-Built Survey by a licensed surveyor, drawn.to scale, showing actual location of all ew con ction Date: l i 0`' Applicant/Builder Signature: The application of dated is hereby approved and permission granted for the construction, reconstructs n or alteration of a building/and or accessory structure as set forth above. Date: Authorized Signature: L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 Application for Permit—Septic Disposal System OJEF Town of Queensbury 742 Bay Road Queensbuiy,NY.12804 (518) 761-8256 � , 1. OWNER INFORMATION: .........................._.............�/Q.�....7...�................ C TOE/ Office'CTA 2005 Location of installation: . c^aNOF '36� - File PermiB 6IN QUF��S RY Tax Map No. Fee Paid Owner's Name: 1............................................................................................................................... Address: 2. INSTALLER'S NAME J `'= _� PHONE NO4~Z� �� 3. RESIDENCE INFORMATION; (circle.year of dwelling, indicate#,bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House. No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gallbdrm = 1980- 1991 x 130_gal/bdrm = 1991 -present _7Z, x 110 gallbdrm = SC--, Garbage Grinder Installed yes— / no Spa or Hot Tub Installed yes_ / no 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) To o a hV SQj11,1ature Ground Water Bedrock or Im ervious Material ater Supply Flat cam -:at what depth at what.depth nici al olling loam feet feet we Steep slope clay if well; water supply ^%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: tC)Z)Q gallon (min. size 1,000 gal.) Tile Field: each trench .�0 ft. Total System Length: ::;-0cQi�-7k ft. Seepage Pit(s): number of size of each:. ft. by , ft. Size of Stone to be used: # Z / depth or thickness feet Bed System Size: x Alternative System: -. length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be.inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION ROR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance know4 by or on behalf of an applicant, shall be void. I have read the regulatio r ect tot 's application.and agree to abide by these and all requirements of the Town of Queens ry Sanitary ew e D'sp 1 Ordinance. gnat of r ponsible person Date Town of Queensbury Sewers and Sewage Disposal Chapter Appendix C ABSORPTION FIELD. SEPARATION REQUIREMENTS POND O Hui— %A tgllT�R SO Appendix C ABSORPTION FIELD SEPARATION REQUIREMENTS POD WA-mv—-rorlmT J f W s s �sl�-rs . '�� AR1h+CYtJl1f • � 3 �, ._ T-' a'nai..'.�.. .r:.,,�-y -s>�-..,.,,.� ,�3:�'�`'e-,ax�-r,1 �;r n�->3w•i:..�'t'F aa>'.^'_.><' - - - �+,:;. rr� .t<. �. • "1 ( � a 41-111 it — a �AN It lit -r 0 ; F . o15. s J . i -l\` iq FN t: R ."+. L� . MAR 17 -A06 0 TOWN r BUILDING CODE -r SCk) , A) ToN Re-L)isIoA-) a0 0gwN �oPe-li�-,� T �o�3� rm*%ECP IV ED MAR 17 106 TOWN Or ;3; II Jpfy BUILDING;,i3O CODE { I ; i I i , i - f r-1 Uc UN,c S aa sa a5.�• r 1s' a ,�lo ja uaa� �k 1ra 7 ryes ona;a - 0 -- ci It , I i z ;� -- -OF:QUE�N��I��'f - -- - -- --- - -. --- --- - ._---- ---- ---..- - _ -- --- '- ----- TOWN BUILDING AND COP ------------ i F i I 1 1 s i : : -- - -- - , r I t t , , 1 , j • Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/prry�Dirt am/pm Date Inspection request received: _ Inspector's Initials: _ -� NAME: "LV 1 PERMIT#: L� LOCATION: ��j—�, � DATE: TYPE OF STRUCTURE: —_5 7--j _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 1 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete S Guard 30 in.or more a�stairs,decks patios �� Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" Gypsum Grade away from foundation'6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site I Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: _v Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fire roofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:\PamW\Building&CodesUnspection Forms\Res. Final Insm form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm ADErt: am/pm Date Inspection request received: Inspector's Initials: r— NAME: �L��'�L_ PERMIT#: LOCATION: .-P O _ DATE: 4Y TYPE OF STRUCTURE: 7 Comments YeV No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet / 6 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: / Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/Y4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Olass nclosure � Final Electrical Final Survey Plot Plifii 5 / c• / C���If}- ' As Built Septic System/Sewer De Ins ction Sticker t. Site Plan /Variance required CA Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doe Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date InspectioArn/pni equest,received: Queensbury Building& Code Enforcement Arrive: D/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: u d G� PERMIT#: o LOCATION: INSPECT ON: �� b TYPE OF S RI]CTURE: Y N N/A /� COMMENTS F�ng ! I FMk Studs/Headers !�f�d(/`j�� �C�(Jl�_� I �- 4,,t) OJ/ Bracing/Bridging �L060Q- P14A) :�P PQC—Al, Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. On Headroom 6 ft. 8 in. P12DU Stairwells 36 in. or more 2&A-y",9 Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls C Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches froln wall Fire separation 1, 2, 3 hour ire wall 2, 3, 4,hour Firesn I g7nMetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Franning Firestopping Inspection Report.doc January 28,2003 Final Survey I Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: /-S S' NAME: LOCATION:IL.Tj—+-S62�,x PERMIT Final Survey Plot Plan Avvroved Denied The attached final survey has been received by the / Dept. of J Community Development. Upon review the survey h en: Craig n, Zoning Administrator Notes: LASueHemingway\Building.Codes.InspectionTORMSTinal Survey Zoning Administrator.doc FILECOPY Bldg. Permit File No. V9� Final . 0 Inspection Approval COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 11545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL JPermit No..�J..`l�V6. � ....Cert. N 2 93329 Cut-in Card No..................................... Owner......................G.1.l,1./.. -........./.n t3..1..�.(�,� l f .. .................................................................... Location...............nr.Z 0....... ....... ........................................................................................... Installation Consisting of.... ..Q.Q./. ...............Ss .�.I 4'-.1......"-�..,3...R. 5L5. j.....1..Z....S.wj........ 1.i�.... T...S.,......1....T. ..t'Z.f..... ...S..mAJ.��...11. lit.t? 5.,......CJ..trS1�................... :..................................................................................................................................................... L:\ Installed By..........S.0-va C...........................................................Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if its rules are violated,the Company shall have the right to revoke this certificate. Date.........Ll.'.. .7..-.Q.6............. INSPECTOR..r.�.�..2 ./_2...................................... Member N.F.P.A.,I.A.E.1. r f ] -3;r--�� Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspect'Qn�e�t received: Queensbury Building & Code Enforcement Arrive: am/ ert: dn m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Ly l�� l�,-1 `,� �C- PERMIT #: 0 5 LOCATION: INSPECT ON: TYPE OF STRUCTURE: oLo Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes nsulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspe tion.re uest Queensbury Building&Code Enforcement Arrive: at Ei/ 01 �`epart: 7-4a-00 a 'p 742 Bay Road, Queensbury,NY 12804 Inspector's Initi 1s ; NAME: PERMIT #: LOCATION: INSPECT ON: � ' TYPE OF STRUCTURE: Y N N/A. 2� PVC: R-1,R-2,R-3,R4 Drain/Vents �� J Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial o er,CPVC,Pex One and Two-Family sulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: (>1/� L-.\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Insp ctioporequest received: Queensbury Building&Code Enforcement Arrive: bj am/pm Dart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: A PERMIT#. 0 n S LOCATION: INSPECT ON: 3--- f — D P TYPE OF STRUCTURE: - Y N N/A COMMENTS ranun 1� I a Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. .� Stairwells 36 in. or more Headroom 6 ft. 8 in. J Notches/Holes/Bearing Walls / Metal S apping for Notches Top Plate 1,'/z _116 g4u e(8) 16D nails each side i �St`,pp ng 1,000 sq. ft. floor trusses a ; or Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation I, 2, 3 hour Fire wall 2 3,4 hour ysa- _ "`Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: : - am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: S'%s LOCATION: INSPECT ON: - D TYPE OF STRUCTURE: Y N NIA C� i PVC: R-1,R-2,R-3, R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. tldmbing Vent/Vents in Place , f— ou h Plulii in /Nail Plates 1 '2 inch min. Drain Size Washing Machine Drain 2 inch min. sH-ead ors .nr-Suipply Test Dra' and Vents SI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction W�t pPly Piping t` Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/ Commercial Check '- Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS Aq4,r:, LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Insp �ti reauest received: Queensbury Building&Code Enforcement Arrive: am/ m!1 epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: �✓ NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30" minimum �� l Jack Studs/Headers /a Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center e and water shield 24 inches from wall C Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins tr equest received: Queensbury Building& Code Enforcement Arrive:� am/p Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Ini ials: 2 NAME: �Y�`y�G� PERMIT#: c� LOCATION: INSPECT ON: a� TYPE OF STRUCTURE: i Framing Y N N/A COMMEN TS Jack Studs/Headers 1� Bracing/Bridging _ Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses ,Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive:rL. 05am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: ClJ U �- PERMIT NO.: LOCATION: INSPECT ON: RECHECK: �. Comments and/or diagram RSoil Type: Sa ` m Clay T e of Wa Municipal/Well Water (3�' Waterline separation ance ft. �� Well separation distance ft. I Other wells: Absorption Field: Total length ft, Length of each trench ft. ,/1 Depth of trenches Size of Stone G Seepage Pits: Number Size: x Stone Size: Piping Sizq A, Type Building to tank b Tank to Distribution Box Distribution Bo ield/Pit % Opening Seale ., Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption t. Separation of Pits ft. Conforms as per Plot Plan Y N Location of System on Property: Front DRearLeft Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved LASueHemingwayU3uilding.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 TOWN-OF QUEE SSUR .. _._ - _ . ...._.._._ BUILD114G AND CODE - B 1 Y i ..c � l 4 #r F �-M) Foundation Inspection Report Office No. (51 i3) 761-8256 Date etii request received: l �� Queensbury Building &Code Enforcement Arriv��`�`="am/ Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:.. NAME: Ci l,/T G PERMIT#: _ C) LOCATION: °2--0 INSPECT ON: Z TYPE OF STRUCTURE: / Comments ti gs Pir —/ e s �q onolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfll Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMWoundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:/ n NAME: PERMIT#: LOCATION: `� INSPECT ON: — 1 TYPE OF STRUCTURE: Comments Y N N/A l Footings Q� Piers - Monolithic Slab Reinforcement in Place The contractor is responsible for ' providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing . Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 ' hes above footing 6 it poly for wet areas under slab B kfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Repoit.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report • �"� Office No.(518)761-8256 Date Inspectionpquest received: Queensbury Building&Code Enforcement Arrive: g /�jSam/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: O 9-S LOCATION: INSPECT ON: TYPE OF STRUCTU Comments Y N N/A otings Piers Monolithic Slab Reinforcement in Place l,s The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM RECEIVED Permit Number NOV 1 5 2005 TOWN OF QUEENSBURY BUILDING AND CODE REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck So$ware Version 3.6 Release 2 Data filename: C:\Documents and Settings\C1uteEntl\Desktop\Meccheck\Untitled.rck PROJECT TITLE: 1040 Ranch COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE:Non-Electric WINDOW/WALL RATIO: 0.10 DATE: 11/15/05 DATE OF PLANS: 11/14/2005 PROJECT DESCRIPTION: 20 Dawn Road Queensbury, NY 12804 DESIGNER/CONTRACT OR: Clute Enterprises Inc. 6 Holden Avenue Queensbury,NY 12804 COMPLIANCE: Passes Maximum UA= 230 Your Home UA= 199 .13.5%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1040 30.0 0.0 36 Wall 1: Wood Frame, 16" o.c. 1056 19.0 0.0 55 Window 1: Vinyl Frame:Double Pane 80 0.490 39 Door 1: Solid 42 0.230 10 Door 2: Glass 21 0.490 10 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 1040 19.0 0.0 49 Furnace 1: Forced Hot Air, 90 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best ofhis/her knowledge, belies; and professional judgment, such plans or specifications are in compliance with this Code. Builder/Designer Date RF�check Inspection Checklist New York State Fnergy Conservation Construction Code REScheck Software Version 3.6 Release 2 DATE: 11/15/05 PROJECT TITLE: 1040 Ranch Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane, U-factor: 0.490 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.230 Comments: [ ] 2. Door 2: Glass, U-factor: 0.490 Comments: Floors: [ ] 1. Floor 1: All Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 90 AFUE or higher Make and Model Number Air Leakage: [ ] Joints;penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non vented framed ceilings, walls, and floors. Materials Identification: Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(Fl iJn to 1" iJp to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 106-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1" and Less 1.25"to 2" 2.5"to 4" Beating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) a , [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point ofthe largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes.to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/ofheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2.