2013-316 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20130316 Date Issued: Wednesday, May 28, 2014
This is to certify that work requested to be done as shown by Permit Number P20130316
has been completed.
Location: 1043 STATE ROUTE 9
Tax Map Number: 523400-296-009-0001-002-000-0000
Owner: TRIBALS LLC
Applicant: DAVIDSON BROTHERS
This structure may be occupied as a:
Commercial Addition By Order of Town Board
Commercial Alteration TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan,Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20130316 Application Number: A20130316
Tax Map No: 523400-296-009-0001-002-000-0000
Permission is hereby granted to: TRIBALS. LLC
For property located at: 1043 STATE ROUTE 9
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: GARY&JILL WILSON
6 BROWNS Path Commercial Addition
UEENSBURY,NY 12804-0000 Commercial Alteration $1,065,000.00
Q Total Value $1,065,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
MUNTER ENTERPRISES. INC.
JOHN MUNTER 518-584-6174
881 MURRAY Rd
MIDDLE GROVE NY 12850-0000
Plans&Specifications
2013-316
Comm. Alterations 19,812 sf& Comm Addition 1,850 sf
[Davidson Brothers]
$4,333.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, October 03,2014
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Thursday, October 03,2013
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
Town of Queensbury Building & Codes
Received:
PRINCIPAL STRUCTURE APPLICATION Tax Map ID: ;kqLa.9
— 8
A permit must be obtained before beginning construction Permit No.:Permit Fee: $ -' C�
Please read: *TB resolution 86-2013(1-28-2013): $850 recreation fee for new dwelling *Rec Fee: $
units, including single-family dwellings,duplexes or two-family dwellings, multiple family Site Plan No.: I S_ -0l 7 7n
dwellings, apartments, condominiums, townhouses, and/or manufactured and modular Subdivision No.:
homes,but not including mobile homes. This is in addition to the perme. s
' .:.i
Date
7/15/13 Applicant TRIBALS, LLC
Tax Map ID Address PO Box 409
Zoning Commercial - Intensive Glens Falls, NY 12801-0409
Phone/E-mail 518-743-9026 aggmanrocks@gmail.com
Property Owner TRIBALS, LLC Contractor/Agent Munter Enterprises, Inc.
Address PO Box 409 Address 881 Murray Road
Glens Falls, NY 12801-0409 Middle Grove, NY 12850
Phone/E-mail 518-793-9026 aggmanrocks@gmail.com Phone/E-mail 518-584-6174 john@munterenterprises.com
Contact Person for Building &Code Compliance: John Munter Day Phone: 5184%81781
Building Street Address: 1043 State Route 9, Queensbury, NY 12804
Subdivision Name: N/A Lot#: N/A Historic Site: Yes X No
Estimated cost of construction: $ 1,065,000
Type of Construction:
Check all that apply Please indicate measurements as required below:
o
a 1st Floor 2nd Floor Other Total Height
Z a a
Single Family
Two-Family
Multi-Family(#of
units_)
Townhouse
Business Office
Retail-Mercantile
Factory-Industrial X 19,612xis ing N/A N/A 21,667 SF xis ing
1 850 SFAddit on 23'4"
Attached Garages(# ) ^S
Other
Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256
If commercial or industrial indicate name of business TRIBALS, LLC
Proposed use of building or addition Brewery and retail store
Source of heat(circle one) Gasf Oil Propane Solar Other
Fireplace-complete a separate application for"Fuel Burning Appliances&Chimneys" Yes X No
Are there structures not shown on plot plan? No
Are their easements on the property? Yes-One existing utility easement for power
Site Information
a. Dimensions or acreage of lot 3.73 Acres
b. Is this a corner lot? Yes-Hidden Farm Road
c. Will the grade be changed as a result of construction: Yes X No
d. Public water or Private well Public
e. Sewer or Private Septic System Sewer
Value of all work to be performed(labor and materials) $1,065,000
Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval. I certify that the application, plans, and supporting materials are a true and complete statement/description of the
work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances,and
in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a
certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Print Name: TRIBALS, LLC
John P. Davidson, Sec./Tress.
Signature: Date: 7/15/13
FOR OFFICE USE ONLY:
Operating Permit Issued: _Yes _No
Occupancy Type:
Construction Classification:
Assembly Occupancy Limit:
Special Conditions:
Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256
Town of Queensbury Building&Code Enforcement
Office No. (518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: �P�LC7?DOt�j\ Inspected on: —Z
Location: P—h0\C=_ 1 Arrive: a.m.
Permit No.: 13— 3 ae Inspector's Initials:
COMMENTS
Y N NA
Chimney I"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch/Step Risers 7"I Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'h doors > 10%>I 000 sq.ft.
a/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
Handicapped Bath I Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.-
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide
Special Inspections/Engineer or Architect Approval �'O Okay To To Issue Temporary or Permanent C/O
Okay To Issue C/C a
Commercial Final Inspection_11 27 12
Commercial Final Inspection Report t J��r»
Office No.: (518) 761-8256 Date Inspection r ed: '
Queensbury Building &Code Enforcement Arrive: `,P m Depart-
742
epar:742 Bay Road, Queensbury, NY 12804 Inspector's In'
NAME: -� ✓l Sorb 3�05. PERMIT C
LOCATION: 10 DATE:
COMMENTS: 110 "
Y N NA
Chimney/'B'Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish 1 Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks �~
Interior 1 Exterior Ballisters 4 in. Spacing Platform/Decks �� 'c—
Stair Handrail 34 in.—38 in./Stop Rlsem 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 in.wllever Handles/Panic Hardware if required l a b
Exits At Grade Or Platform 36 w x 44'(lyCanopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Wateftht i Other Floors Oka
Relief Valve Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Sup&for Occu /Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Wdhin 30 ft or Within Line Of Site
Oil Furnace Shut Off at Entrance to Fumace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors
> 100/0> 1000 sq.ft.
%Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Damp2rs i Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft Wood Frame
Attic Access 30"x 20'x 30'(h), Crawl Space Access 18"x 24'
Smoke Vents Or Fan, if required
Elevator Operation and Si /Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in. Checkout 36"
Handicapped Ramp/Handrails Contfnuous/12 in. Beyond[Boar
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Sury , New Structure/Flood Plain certification if
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Buildingor Driveway 4'
Water Fountain or Cooler
Building Access A&Sfdqs by2 '1 Driveable Surface 20'wide
Okay To Issuerem45 rmanent C/O
Okay To Issue
LABuilding&Codes ForrnMBuilding&Codeskinspecdon FormslCommercial Final Inspection Report.doc Revised January 7,2008
Town of Queensbury Building&Code Enforcement d"' ` ����
Office No. (518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: Inspected Inspected on: j� {
Location: Arrive: =v m D.M.
Permit No.: f 3-3 an Inspector's Initials:
COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch-38 inch/Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv. _
Gas Valve Shut-off Exposed&Regulator(18")Above Grade mac' t X7,VL�,- VS_�N
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap/Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area i l t SLE t��aJjv
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Yz doors > 10%> 1000 sq.ft.
%Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped ssible
Handicapped Service Counters 34 inch,Qeckout 36 inch .
Handicapped Ramp/Handrails Continuous/12 inc eyon o sides] _�
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded If
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification, if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4" E7 rTr. Ct:R i i�it�R-itt
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide
Special Inspections I Engineer or Architect Approval
Okay To Issue Temporary or Permanent CIO _
Okay To Issue C/Cv�--�,
Commercial Final Inspection_11 27 12
Inspection Form
Town of Queensbury Fire Marshal CD Periodic Inspection Date:`'I / � Time:_
742 Bay Road,Queensbury NY 12804 (::::�Re-Inspection ]
518 761 8206/518 761 8205 SCO Inspection Permit#: 13
Fire Marshals Representative
YMJ Palmer Business Name:
Location:
GK Stillman Contact: Lyr`I%
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Si n: Normal FC 1011 &FC1029 ( �Qif �r� - (���2
Sign: backupFC 1011.5.3&FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906
EVAC Plan FC 404.2
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING: y
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1 "-
Interior Finishes FC 803-804 —
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6(R1 &112
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTIONDUE APPROXIMATELY
Vacant Buildings FC 311
Emergency Disconnect FC 2203.2 21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC
Kitchen Suppression Semi Annual Flr 'Mamb 1910, to
Fuel Island Suppression Semi Annual �� && 3� Mal
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506
MAY 1,.' t. 201
Operating Permit, if required will be issued after
Completion of Inspection Fire Marshal
Town of s u
Town of Queensbury Building&Code Enforcement
Office No. (518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: BRb�) Inspected on: _ Z—
Location:
L' �J ���1 ���' 1=C Arrive: p.m.
Permit No.: "_ CL Inspector's Initials:
�� _ ��� ��� 1� im COMMENTS
Y N NA
Chimney I"B"Vent I Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch/Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap/Water Temperature 110 Degrees Maximum
Boiler I Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 sq.ft.
'/4 Hour Corridor Doors&Closers
Firewalls I Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
levator Operation and Signage/Shaft Sealed
andicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
andicapped Bath/Parking Lot Signage
ublic Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 inch Checko3 a c
Handicapped Ramp/Han rails Continuous112 inch
Active Listening System and Signage Assembly Space POW F-,)w
final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification, if req. ���
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide
Special Inspections/Engineer or Architect Approval
Okay To Issue Temporary or Permanent C/O
Okay To Issue C/C L
Commercial Final Inspection_11 27 12
PN= kXY �C_Ibvei
Foundation Inspection Report
Office No.(518)761-8256 Date inspection request received: LY< I�l Y
Queensbury Building&Code Enforcement Arrive: JQQ am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 inspector's Initials:
NAME: 11>V'JA SOA PERMIT#: ' 31
LOCATION: )U v 1, 57--Ai e i INSPECT ON:
TYPE OF STRUCTURE:
COMMORk
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. �
Foundation/Wallpour L c:�faf`5 e�L
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Town pf Queensbury Building&Code Enforcement �
Office No.(518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: DIS Inspected on: —'
Location: 1 L 't(_ A` I-) Arrive: a.m./
Permit No.: �� i Cr- Inspector's Initials:
_ ] COMMENTS
Y N NA
Chimney/'=B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete - co�
Exterior Finish/Grade Complete 6"in 10'or Equivalent 4 C�_
- �
Interior/Exterior Guardrails 42 inch Platform/Decks /
Interior/Exterior Balusters 4 inch Spacing Platform/Decks � L \ LCF�1�e►.+�
Stair Handrail 34 inch-38 inch/Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft. / t
All Doors 36 inch w/Lever Handles/Panic Hardware,if required C-0, C__N
Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay fat �}�c� , , (�
Relief Valve,Heat Trap/Water Temperature 110 Degrees Maximum z 1 G
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion -z r.— i
Low Water Shut Off For Boilers ��
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors >10%> 1000 sq.ft.
%Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame ��
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors '' ��
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible V�
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required �(�� �� �� ✓ ��
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File rr�� ..�--^^{ '
Building Number or Tenant Address on Building or Driveway 4" t.-�--s v7r-'f G
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide -\v cc t f_
Special Inspections En ineer or Architect Approval
Okay To Issu Temporary°br Permanent C/0 N 1 L1 �� t4
Okay To Issue C/C j L)(:-:-V
Commercial Final Inspection_11 27 12
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256
Framing / Firestopping Inspection Report
Inspection request received:
Name: Inspected on: ry
Location: 1 C)Y? �) PFVE PLOT C1 Arrive: Z Q a.m.-mm
Permit No.: —,�3 Inspector's Initials:
TYPE OF STRUCTURE: RD \ OC—)
Y N N/A COMMENTS:
Framing �T\
Attic Access 22"x 30"minimum
Jack Studs 1 Headers
Truss Specification Provided
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8)16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side'/Z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off, if required
Framing/Firestopping Inspection Report --= '�
PAONE ARCHITECTURE,P.C.
INTERIOR DESIGN • CONSULTING
547 RouTE 9P,SARATOGA SPRINGS,NY 12866
518-58o-ooi7 FAx 518-58o-ooi8 WWW.PAONEARCHITECrURE.COM
APRIL 4, 2014
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
742 BAY ROAD
QUEENSBURY, NEW YORK 12804
RE: DAVIDSON BROTHERS BREWING COMPANY
RENOVATION/ADDITION
1043 U.S. ROUTE 9
QUEENSBURY,NY 12804
MR. O'BRIEN:
THE OFFICE OF PAONE ARCHITECTURE, PC HAS REVIEWED THE 1,800 SF ADDITION TO THE
EXISTING BUILDING,AT THE ABOVE ADDRESS, AND FOUND IT TO BE CONSTRUCTED IN GENERAL
OVERALL COMPLIANCE WITH THE DRAWINGS PREPARED BY AMERICAN BUILDINGS COMPANY AND
THE OFFICE OF PAONE ARCHITECTURE, PC.
THANK YOU FOR YOUR TIME AND AS ALWAYS, PLEASE FEEL FREE TO CONTACT OUR OFFICE WITH
ANY QUESTIONS YOU MAY HAVE.
REGARDS,
PAONE ARCHITECTURE, P.C.
BY:
i
NAME: JOHN A. PAONE, RA
TITLE: PROJECT ARCHITECT
-in of Queensbury Building&Code Enforcement
Uffice No.(518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: /�
Inspected on:
Location: f% ` 3 sq--r- _ Arrive: lo^ a.m p.m.
Permit No.: '��/(c% Inspector's Initials:
COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch-38 inch/Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv. U3 t
Gas Valve Shut-off Exposed&Regulator(18")Above Grade1 iL' ��
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap/Water Temperature 110 Degrees Maximum �t,��
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing Systeme _
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers v tj c
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site _
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. -�-� ��04� '
'/<Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Framed 1�1 lj� Z�j CMf �
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible l7 C` t=- C-,F- k2>OkL�)4�36
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification, if req. �-
As-built Septic System Layout Required or On File i
Building Number or Tenant Address on Building or Driveway 4" C-
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide IT 1�
Special Inspections/Engineer or Architect Approval 7
Okay To Issue Temporary or Permanent C/O
Okay To Issue C/C
Commercial Final Inspection_11 27 12
Town of Queensbury Building&Code Enforcement 4a qn—u
Office No. (518)761-8256
Commercial Final Inspection Report 6 /YVI--,�� �� �
Inspection request received:
Name: � Inspected on:
Location: 16 41.3Arrive: Za.m I .
Permit No.: zInspector's Initials:
G' L COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location CIO,
Plumbing Vent Through Roof 6"/Roof Complete 1
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks f
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch 1 Step Risers 7"1 Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay iQA Q
Relief Valve,Heat Trap/Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area z' 1 ���
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%>1000 sq.ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed �
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required ��
Final Survey,New Structure/Flood Plain certification,if req. �� �7-
As-built Septic System Layout Required or On File ` o
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide
Special Inspections/Engineer or Architect Approval
Okay To Issue temporary:dr Permanent C/0
Okay To Issue
Commercial Final Inspection-11 27 12
'E uPs 1-3
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive. am/pm
742 Bay Road, Queensbury, NY 12804 Inspect6u
is I ials:
NAME: �Q�` a 3.0 1\ PERMIT#: 1!�
LOCATION: 1,6:)4f, R±f? INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Plumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping ��"..
Air/Head
50 P.S.I. for for 15 minutes
Insulation /Residential Check/Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection-02 05 13
Town of Queensbury Building &Code Enforcement
�� � ?
Office No. (518) 761-8256
Framing / Firestopping Inspection Report
Inspection reques received: -t�—! 7 P--0 t — I �C S --
Name: �'�� _ �- Inspected on:
Location: 1031� / Arrive: a.m 1P.
Permit No.: o - Inspector's Initials:
r
TYPE OF STRUCTURE: Adi.
Y N N/A COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing/BridgingT —
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in. �7
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8)16D nails each side
Draft stopping 1,000 sq.ft.floor trusses _
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall r
Fire separation 1,2,3 hour �`/ ti�� �M--, --�,
Fire wall 2,3,4 hour t 141'16
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation -
House side Y2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/ Firestopping Inspection Report
Foundation Inspection Report p,
Office No.(5 18)761-8256 Date Inspection request ed:
Queensbury Building&Code Enforcement Arrive: ZL-LZ epart: In
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: RMIT#:
LOCATION: 3 SPECT ON: 5, -1
TYPE OF STRUCTURE:
Co m n
Z
Y N A
Footings
Piers
Monolithic Slab
Reinforcement in Place y � � \ ►J �� O v��
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
UXBuilding&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Town of Queensbury Building & Code Enforcement f
Office No. (518) 761-8256 rJ
Framing I Firestopping Inspection Report
Inspection request received:
Name: b GZt Inspected on: /✓���
Location: D ,
��-� `�—�� Arrive: •- a.m./p.m.
Permit No.: r i r Inspector's Initials: /d
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs I Headers
Truss Specification Provided
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side'/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/ Firestopping Inspection Report
C
Foundation Inspection Report
Office No.(5 18)761-8256 Date Ins ection reques i
Queensbury Building&Code Enforcement Arrive: �" Depart: pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: ON �S 0', D 1,v-v PE T#:
LOCATION: U Ll A.uLTe ? IN PECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement C>
of the concrete. � �
Materials for this purpose on site. AV
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
7Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report '4 �- J
Office No.(5 18)761-8256 Date on
Queensbury Building&Code Enforcement Arrive: 'on �Depaftt:
' — ' LA m
:e. --b— -' ep�rT-J.�L
742 Bay Rd.,Queensbury,NY 12804 Inspector s Initial
NAME: T#:
PELT ONW: zluzud
LOCATION- 0 S' 'T t
TYPE OF STRUCTURE:
Conso
Y N NA
fFootings
Piers
Monolithic Slab A (z---, �\jv I
Reinforcement in Place -V
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Danipproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing brain Stone:
12 inch width
6 inches above footing
6 mil po!y for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Bullding&Codes Forms\Buflding&Codes\lnspettlon Forms\FoundWon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office.No.(5 18)761-8256 Date motion
Queensbury Building&Code Enforcement Arrive: l i In epart:
742 Bay Rd.,Queensbury,NY 12804 Inspector's
74--124120
, ii�0
NAME: 1IT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: Ca MI
Conimelk
Y &A
Footings
Piers 3
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement 4cd
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Dram Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil R21y for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
U\BuIlding&Codes Forms\Sullding&Codes\lnspetdon Forms\Foundatlon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report D "-r v
Office No.(518)761-8256 Date Inspection request received: ��
Queensbury Building&Code Enforcement Arrive: ,241 am/13M Depart: pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
I
6
NAME: i�V i Sin `d -17—V PERMIT#: ��_
LOCATION: (0 Si C iZ i1vTe INSPECT ON:
TYPE OF STRUCTURE:
Co m n
Y N NA 1
outings c
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Cortes Forms\Building&Codes\Inspettlon Forms\Foundation Inspecction Report.doc
Last printed 12/20/2005 9:24:00 AM
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request re �ved: l� 13
Queensbury Building & Code Enforcement Arrive: --7,r—> m
742 Bay Road, Queensbury, NY 12804 Inspector's Initial
NAME: 1`��t✓to 5 Gtr ��0 S PERMIT#:
LOCATION: 7z S 11-1F ��\C INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
lumbing under slab ,
Rough Plumbing /Nail Plates )<1 -
Plumbing Vent/Vents in Place A Tv
11/2 inch minimum Drain Size y�
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
t- h�'� l\�
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I. for for 15 minutes
Insulation /Residential Check/Commercial Check
Window Sealing \
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing—insulation Inspection-02 0513
--i jj c.uw
Foundation Inspection Report
Office No.(518)761-8256 Date action r i
Queensbury Building&Code Enforcement Arriv Depart: f1 j�
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial • -
NAME: D64A� .�-, B PERMIT#: / 3--,31(o
LOCATION: I d� ,l INSPECT ON: /a—/A=43
TYPE OF STRUCTURE:
Co m n
Y N NA r
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil po!y for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\lnspetdon Fonns\Foundatlon Inspectieon Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(5 18)761-8256 Date tion req
Queensbury Building&Code Enforcement Arrive: in Part:
742 Bay Rd.,Queensbury,NY 12804 s Initi
NAME: A. RMIT#: 3
LOCATION: INSPECT ON:
TYPE OF STRUCTtn-
Conn mela
Y N &A_
Footings �-NV\Qc— �
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place A/
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
U\Building&Codes Forms\Bullding&Codes\lnspetbon Forms\Foundal:lon Inspection Report-doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(5 18)761-8256 Date Inspection reque
Queensbury Building&Code Enforcement Arrive: Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: v�� \C7tiC�e7 ? a P T#:
LOCATION: SPECT ON: -- =-c
TYPE OF STRUCTURE:
Can m n
Y N NA
Footings
Piers
Monolithic Slab
Reinforcement in PlaceC�\
The contractor is responsible for ` -`- F� q C)C A
providing protection from freezing
for 48 hours following the placement � `C \T� C V\i:) \JC��
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place `'
Foundation Dampproofing -r-.\AE
Foundation Waterproofing
Footing Drain Daylight or Sump
�Cj �p
Footing Drain Stone: (D
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
PAONE ARCHITECTURE,P.C.
INTERIOR DESIGN 0 CONSULTING
547 ROUTE 9P,SARATOGA SPRINGS,NY 12866
518-58o-o017 FAX 518-58o-oo18 WWW.PAONEARCBITECTURE.COM
DECEMBER 9, 2013
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
742 BAY ROAD
QUEENSBURY, NEW YORK 12804
RE: DAVIDSON BROTHERS BREWING COMPANY
RENOVATION/ADDITION
1043 U.S. ROUTE 9
QUEENSBURY,NY 12804
MR. O'BRIEN:
THE CONTRACTOR, ON THE ABOVE MENTIONED PROJECT,HAS REQUESTED TO SUBSTITUTE THE
FOUNDATION SLAB REINFORCING, #4 BAR AT IZ O.C. EACH WAY IN THE DOCK LEVELER PIT,WITH
6X6 D7.5/D7.5 WELDED WIRE FABRIC SHEET REINFORCING. PAONE ARCHITECTURE TAKES NO
ISSUE WITH THIS, SO LONG AS THE ADJACENT DOWELS ARE PLACED AND TIED ACCORDING TO THE
DRAWINGS.
THE CONTRACTOR HAS ALSO REQUESTED TO SUBSTITUTE THE FOUNDATION SLAB REINFORCING,
6X6 W1.4/W1.4 WELDED WIRE FABRIC (6X6 1010 WWF) AS SPECIFIED BY THE GRAIN SILO
MANUFACTURER IN THE EXTERIOR GRAIN SILO PAD,WITH 6X6 D7.5/D7.5 WELDED WIRE FABRIC
SHEET REINFORCING. PAONE ARCHITECTURE TAKES NO ISSUE WITH THIS, SO LONG AS THE WWF IS
CENTERED IN THE SLAB.
THANK YOU FOR YOUR TIME AND AS ALWAYS, PLEASE FEEL FREE TO CONTACT OUR OFFICE WITH
ANY QUESTIONS YOU MAY HAVE.
REGARDS,
PAONE ARCHITECTURE, P.C.
BY:
NAME:JOHN A. PAONE, RA
TITLE: PROJECT ARCHITECT
Foundation Inspection Report
Office No.(5 18)761-8256 Date In ction�requss
Queensbury Building&Code Enforcement Arrive: ". p epart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's tial
a fy
NAME: P R,,fv IT#: ! — 2.f Lr
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Co m n
Y N NLA
Footings
Piers
Monolithic Slab r
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete. _
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing ,
Footing Drain Daylight or Sump
Footing Drain Stone: b
12 inch width
6 inches above footing r1 N
6 mil poly for wet areas under slab 61MVF s T� \
Backfill Approval `_
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspectlon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Repoo l --�
Office No.(518)761-8256 Date Inspection requ e i 3
Queensbury Building&Code Enforcement Arrive: [) p epart:
742 Bay Rd.,Queensbury,NY 12804 Inspector's Inti s:
� 7 "
NAME: V! S cv-� i�)r`` 6 PERMIT#: '
LOCATION: S�T ic ►t.�v [— INSPECT ON: 3
TYPE OF STRUCTURE:
columenu
Y N NA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 nail poly for wet areas under slab /r
WBackfdl'Approval
Pumbing Under Slab
VC/Cast/Copper
Foundation Insulatio #eri Exterior
t
•-R'- ` 1 L
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Founda0on Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(5 18)761-8256 Date biwtion requ
Queensbury Building&Code Enforcement Arrive:A7 VQ � In W- ;=jm�=���
742 Bay Rd.,Queensbury,NY 12804 ts Initials.
NAME: ERMIT#: -3
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
N NA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
Of the concrete.
Materials for this pw
jLose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
.6 inches above footing
6 mil poly for wet areas under Slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Bulldlng&Codes Forms\Bullding&CodeAInspettion forms\Foundabon Inspection Report-doc
Last printed 12/20/2005 9*24:00 AM
Foundation Inspection Report
Office No.(518)761-8256te , o
Queensbury Building&Code Enforcement Arrive: Depart: C,tiD
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials
NAME: !U�.� S� D o T#: l 3-3r Lp
LOCATION: INSPECT ON: i 1 —_L3
TYPE OF STRUCTURE: z Z6 r_ � }� f
Co m n
N NA
Footings
Piers
Monoliithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil R2!y for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
U\Building&Codes Fon»s\Building&Codes\Inspeddon Fonns\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date hispection e
am/vm
Queensbury Building&Code Enforcement Arrive:
n
tio ved,
Ile 'ved:
742 Bay Rd.,Queensbury,NY 12804 Inspector 11nitti
P
NAME: P RMIT#:
T
LOCATION: 1p�Az 6-yei S=PECT ON:
TYPE OF STRUCTURE:
Cont ms
Y YN
N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place —ME
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for thisse pur
4m on site. �uc
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing;
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil Rk for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation insulation interior/Exterior
Rough Grade 6 inch drop within 10 ft.
L:\Bulldlng&Codes Forms\Bullding&Codes\lnspettlon-Forrns\Foundafdon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
PAONE ARCHITECTURE,P.C.
INTERIOR DESIGN • CONSULTING
547 ROUTE 9P,SARATOGA SPRINGS,NY 1.2866
518-58o-ooi7 FAx 518-58o-ooi8 WWW.PAONEARCHTTECTURE.COM
AUGUST 2, 2013
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
742 BAY ROAD
QUEENSBURY, NEW YORK 12804
RE: DAVIDSON BROTHERS BREWING COMPANY
RENOVATION/ADDITiON
1043 U.S. ROUTE 9
QUEENSBURY, NY 12804
TO WHOM IT MAY CONCERN:
THE CONTRACTOR, ON THE ABOVE MENTIONED PROJECT, HAS REQUESTED TO'WET SE-e THE
FOUNDATION/RETAINING WALL REINFORCING. PAONE ARCHITECTURE TAKES NO ISSUE WITH THIS,
SO LONG AS WHEN PLACED, THE DOWELS ARE CENTERED IN THE FOOTINGS/FOUNDATION WALL
AND/OR ALLOW FOR REQUIRED CLEARANCES AT FACES OF WALLS AND PIERS AS NOTED IN THE
DRAWINGS.
THANK YOU FOR YOUR TIME AND AS ALWAYS, PLEASE FEEL FREE TO CONTACT OUR OFFICE WITH
ANY QUESTIONS YOU MAY HAVE.
REGARDS,
PAONE ARCHITECTURE, P.C.
BY:
1
J
NAME: JOHN A. PAONE, RA
TITLE: PROJECT ARCHITECT
f,. r
Foundation Inspection Report t(
Office No.(5 18)761-8256 Date motion ed
Queensbury Building&Code Enforcement .Arrive: Depart:
742 Bay Rd.,Queensbury,NY 12804 Inspector's S.
y _ '.
NAME: P RMIT#: I : —A(P
LOCATION: 0 3 INSPECT ON:
TYPE OF STRUCTURE:
N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this Riaose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
U\BuIlding&Codes Forms\Buliding&Codes\InspeWon Forms\Foundation Inspection Report.doc