2015-227 TOWN OF QUEENSBURY
cora742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20150227 Date Issued: Tuesday, August 11, 2015
This is to certify that work requested to be done as shown by Permit Number P20150227
has been completed.
Tax Map Number: 523400-279-017-0002-028-000-0000
Location: 72 SUNNYSIDE RD. NORTH
Owner: WENDY& EDWARD SCHMIDT
Applicant: WENDY& EDWARD SCHMIDT
This structure may be occupied as a:
Septic Alteration Residential
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the A
property owner of the responsibility for compliance with Site Plan, (DJ /Q/
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code nforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20150227 Application Number: A20150227
Tax Map No: 523400-279-017-0002-028-000-0000
Permission is hereby granted to: WENDY& EDWARD SCHMIDT
For property located at: 72 SUNNYSIDE RD. NORTH
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: WENDY& EDWARD SCHMIDT
255 WEST END Dr Septic Alteration Residential
UNIT 4306 Total Value
PUNTA GORDA FL 33950-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
BP 2015-227 Wendy Schmidt 72 Sunnyside Road North
Residential Septic Alteration
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,June 03,2016
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T wn of een ryji t, ay,June 03,2015
itf "''
SIGNED BY ` for the Town of Queensbury.
Director of Building&Code Enforcement
SEPTIC DISPOSAL PERMIT
Office Use Only
DATE .. d" !S c' 1, Received
TAX MAP ID 279.17-2-28 'I Tax Map ID Permit No >ir-1`1•! -� 'ab h ; -
I I �ii�ir Per'R�itC ee ' ' I
LOCATION OF INSTALLATION 72 SUNNYSIDE ROAD NO TH 1/
Approvals.
i"OWN OF ,:., )LiLiRY
BUILDINv&CODES
APPLICANT WENDY SCHMIDT PHONE/E-MAIL (941)626-7915
ADDRESS 255 WEST END DR.,UNIT 4306,PUNTA GORDA FL 33950
INSTALLER/BUILDER: PHONE/E-MAIL
ADDRESS:
OWNER (SAME AS APPLICANT) PHONE/E-MAIL
Address
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: HUTCHINS ENGINEERING PHONE (518)745-0307
RESIDENCE INFORMATION
Year Built #of bedrooms X Gallons per bedroom =Total Daily Flow
1980 or older Garbage grinder installed Y ✓ N
•
1981-1991 Spa or Hot Tub installed _Y ✓ N
1992-Present 2 110 220
PARCEL INFORMATION
Topography ✓ Flat rolling Steep slope _ %slope
Soil Nature ✓ Sand Loam Clay Other
Groundwater At what depth? >72"
Bedrock/Impervious Material At what depth? >72"
Domestic Water Supply Municipal ✓ Well (if well,water supply from any septic system absorption is 100 ft.)
Percolation Test Rate: 1-5 per minute per inch(test to be completed by licensed engineering/architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION
Tank Size 1,000 gallons(minimum size 1,000 gallons,add 250 gallons to size for each garbage grinder or spa or hot tub)
System Type Absorption field with#2 stone Total length ft.; Each trench x
Seepage Pit with#3 stone How many: _;size
Alternative System Bed or other type? 10'x 25'(250 SF)ABSORPTION BED
Holding Tank System Total required capacity? Tank size #of tanks
Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer
allow systems to be covered until such time as an As-Built plan is received & approved. The installed system must match the septic system
layout on file—no exceptions.
DECLARATION: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or
failure to make a material fact or circumstance know by or on behalf of an applicant, shall be void. I have read the regulations
and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
Print Name: WENDY SCHMIDT f ;
Signature: .11111r r Date:
i ..gyyw'J4 '- '- 7
Town of Queensbury Building&Codes GI � Septic Disposal Permit Ju y 2014
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256
Septic Inspection Report
Inspection request received: Zo 15
Name: C_Innnik ciInspected on:
Location: 1-2 cS i-vIS adz. Lad Arrive: a.m.l p.m.
Permit No.: 15-22'x- Inspector's Initials: haiA
Comments and/or diagram
Soil Type: Sand/Loam/Clay
Type of Water: Municipal/Well Water
Waterline separation distance ft.
Well separation distance ft.
Other wells: ft.
Well Casing Length 50'+/- Y N N/A
[150'to well required if NO]
Absorption Field: Total length ft.
Length of each trench ft.
Depth of trenches ft.
Size of Stone
Seepage Pits: Number
Size: x
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box
Distribution Box to Field/Pit
Opening Sealed: _Y N
End Cap Y N
Inlet/Outlet Pipes&Baffles _Y_
Manholes 12"or less below gr.d,• _Y
[provide extension collar if Yes,/ Y N
Location/Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits _ ft.
Conforms as per P Ian N
Engineer Report an As-Built N
ETU Maintenance Con ract provided
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
System Use Statu .
Approved
Partial Approved and needs to be re-inspected, please call the Building&Codes Office
Disapproved
Septic Inspection Report
.. 169 Haviland Road
Queensbury, NY 12804
Hutchins Engineering Phone: (518)745-0307
g g Fax: (518)745-0308
July 24, 2015
Town of Queensbury Building Department
742 Bay Road
Queensbury, NY 12804
Re: Septic System Installation
Wendy Schmidt
72 Sunnyside Road, Tax Map ID: 279.17-2-28
Our office prepared a wastewater replacement design for Wendy Schmidt at the above-
referenced property. The system consists of a 1,000-gallon precast concrete septic tank, a 500-
gallon precast concrete pump station, and a 10' x 25' absorption bed.
A representative from our office visited the site during system installation. Based upon our site
inspection and our discussions with the installers, it is my opinion that the system was installed
in general conformance with the design prepared by our office and the attached record drawing.
Please contact me if you have any questions or if you require additional information.
Best Regards I
,.
-7-4-7---;:ou.., ` '
1114". *IP Niiiiiw
G. Thomas Hutchins, P.E.
Enclosure
Cc: Ms. Wendy Schmidt ZOt an
JUL0 L,.. ______ 1,\ji
2 4 2015
\.\,,
ti�vi 0 CaUEENS BURY
TO
BUit_DINC&CODES
G.Thomas Hutchins,P.E.
Town of Queensbury Building & Code Enforcement fk
Office No. (518) 761-8256 ��ll
Septic Inspection Report c ?7 ;(�-( <d'"`'
Inspection request received: 7/1 3/1i
Name: r'/-i. 136.14611 n Inspected on: • /��
Location: -71-4 "ehr z / Arrive: 4llrirallr a.m./p.m.
Permit No.: ��' � Alf—r4 Inspector's Initials: I `
/$(-;?;-7
Comments and/or diagram
Soil Type: Sand/Loam/Clay
Type of Water: Municipal/Well Water Q ��}�- `43
Waterline separation distance ft. !
Well separation distance ft.
Other wells: ft.
Well Casing Len i th 50 +/- Y N N/A
[150'to well req ired if NO]
Absorption Field Total length ft.
Length of each t -nch ft. ` / -�2 '`F
Depth of trenche• ft. `V �_
Size of Stone
Seepage Pits: Nu ber
Size: x ct
��'
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box CR, ii/
Distribution Box to Field/ it �� •
Opening Sealed: Y N � _(7>tX(A . 17..1� � � _
End Cap _Y N
Inlet/Outlet Pipes&Baffles
Manholes 12"or less below grade Y N
[provide extension collar if Yes] Y N
Location/Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan N
Engineer Report and As-Built _Y N
ETU Maintenance Contract provided _Y N
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
S stem Use Statu-.
• Apse -•
'artial Approve. :nd needs to be re-inspected, please call the Building&Codes Office
-.e -•
Septic Inspection Report (�
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No. 1 sc—'2.17 Cert. N2 27750 Cut-in Card No
Owner £:Ji 3.c.h.vn tc l
Location 7.2. I.s rt rt y.SC..u.tc. r.a..bee R/
Installation Consisting of .cl..T'-c 4,.uvrite crx
Installed By /.�.l rttK...l 9#z.To Lic.No.
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules are violated,the Company shall have the right to revoke this certificate.
Date 7 INSPECTOR 1.72--"?..4.1..-
Member
.7'J
Member N.F.P.A.,I.A.E.I.
Town of Queensbury Building & Code Enforcement /
Office No. (518) 761-8256
Septic Inspection Report
Inspection request received:
Name: c.,Lt Inspected on: -rS
I
Location: --V2— !.
S• T' -V`-111Z-Li\>, - iq Arrive: - a.m./p.m.
Permit No.: 4_5' 27-71 Inspector's Initials: C./A
Comments and/or diagram
Soil Type: and oam/Clay
Type of Wa er: Municipal/Well Water
Waterline separation distance ft.
Well separation distance ft.
Other wells:
Well Casing Length 50'+/- Y N N/A
[150'to well required if NO]
Absorption Field: Total length ft.
Length of each trench 21f, ft. ... /01'
Depth of trenches ft.
Size of Stone e4 Z._ 63.g757 G f
Seepage Pits: Number �� `���'' UU l
Size: ► 14-4 /Z7X 2+c
Stone Size:
Piping Size Type
Building to tank
kt
Tank to Distribution Box '411 , -j
id
Distribution Box to Field/Pit 51",2 3 c-Fa---{p
Opening Sealed: Y N
End Cap V_N /,‘,wVal)
Inlet/Outlet Pipes&Baffles N
Manholes 12"or less below grade Y_N
[provide extension collar if Yes] Y N
Location/Separations (_ .g'E- /,‘A'-‘6('-\
Foundation to tank _ft.
Foundation to absorption ft.
Separation of Pits ft. 2F7 ,(Gd1(� /�,—
Conforms as per Plot Plan _Y_N �QV V j f� / Z��
Engineer Report and As-Built _Y N Cy �wC 2- �--'
ETU Maintenance Contract provided Y_N
Location em on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
System Use Status:
Approved
Partial Approved and needs to be re-inspected, please call the Building&Codes Office
Disapproved 0
Septic Inspection Report
I
Plitt r
S^
Y
a
k
t
r,yY
i l
i
tb ,
i
�h
I'
I
<.
rf, ! on:!"J",
t" 5. t
Town of Queensbury Building & Code Enforcement -T> S
Office No. (518) 761-8256 9--\\
Septic Inspection Report
Inspection request received: le'P315 I
Name: 5ck- Inspected on: �1 " 15
Location: `L �S Ick Arrive: IIIP a.m.l p.m.
Permit No.: 1 5—22'1— Inspector's Initials: ef-A5k) ,
Comments and/or diagram
Soil Type: Sand/Loam/Clay
Type of Water: Municipal/Well Water I/�SLJ6 4A 0
Waterline separation distance ft. C
Well separation distance ft. 1
Other wells: ft.
Well Casing Length 50'+/ Y_N N/A
[150'to well required if NO] ()C_CX\--10)IX
f ATAAS
Absorption Field: Total length ft.
Length of each trench ft.
Depth of trenches ft.
Size of Stone (5-214cre5-t —
Seepage Pits: Number
Size: x
Stone Size:
Piping Size Type
Building to tank 4`t 4! v, /(,-12,A, ,��g�
Tank to Distribution Box � ��
Distribution Box to Field/Pit t( cl0 � .
Opening Sealed: _Y_N L-)_ A-a- r,�
End Cap Y vI
Inlet/Outlet Pipes&Baffles _Y v1( Ct --
Manholes 12"or less below grade Y_N A
[provide extension collar if Yes] _Y—N
Location/Separations
Foundation to tank 1—ft. 'l -1/4-
Foundation to absorption ft.
Separation of Pits ..e.,....--...
Conforms as per Plot Plan Y IIN
Engineer Report and As-Built Y 4 N
ETU Maintenance Contract provided 1
Locatio ys e on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
System Use Stat ::
":.1r '-.
Partial Approved a I needs to be re-inspected, please call the Building&Codes Office
Iisa,,ro OP
Septic Inspection Report
o:.
LANDSOF /
RAYMOND R..SORESINO
PATRICIA ANN SORES/NO
40371104
3
SECOND
4" PVC SDR -35
INLET
MIN. SLOPE
1/4" PER FOOT
WATERTIGHT SLEEVE-`
AND SEAL (TYP)
PROPOSED 1000 GAL
PRECAST CONCRETE
SEPTIC TANK
SV
L j!
LANDSWFAF
FRANK C. RICCIO
PHYLLIS M. RICC10
973304
2
J
SIDE
�—
\ D NORTH
\\ ROA
10' P.L. SETBACK
w \ (W/W FIELD)
o
N
0
100' MIN.
K � t
v PROP. 10'x25'D 5UgT
STONE ABS. BED THIR
13 \
100' LAKE SETBACK 27, tan'= SO. FT.
(W/W FIELD) / �'6.sz: ACRES
t
PROP. 1-1/2"
HDPE FORCEMAIN 12'±
PROP. 500 GALLON
CONCRETE PUMP TANK
CONCRETE
RETAINING WALL
/PROP. 1000 GALLON
O jig CONCRETE SEPTIC TANK
—EXISTING SEP71C SYSTEM
TO BE DECOMISSIONED
PROP. 4'
a HOUSE SEWER ='. CpMp
cn
pOR
7.5't
POTENTIAL w
A WATER
N
\ WELL w
\LOCATION
\ i
LAKE w�Cp,
x
WASTEWATER SYSTEM PLAN
SCALE: 1"=30'
ALONG
APPROXIMATE
FINISH GRADE
GARAGE__--
-�f 10
WELL LOCATION gpJOWERS
PER NEIGHBOR CABIN
lT wSIBLE !'
S UNNYSIDE
LANDS WF OF
KENNETH B JOANALDOUS
509/330
POLYETHYLENE EXTENSION TO GRADE POLYETHYLENE EXTENSION TO GRADE
W/TAMPER RESISTANT ACCESS COVER W/TAMPER RESISTANT ACCESS COVER
° e
SEPTIC TANK NOTES
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE
DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS
MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT.
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE.
WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE A STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY
CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID
LEVEL MUST BE TESTED BEFORE BACKFILLING.
16" MIN
APPROXIMATE
EXISTING GRADE
10' BED WIDTH
4" MINIMUM TOPSOIL ON
ENTIRE BACKFILL AREA;
SEED AND ESTABLISH TURF
BACKFILL MATERIAL AS NEEDED \-10'x25' CRUSHED STONE
TO ESTABLISH GRADES ABSORPTION BED
ABSORPTION BED SECTION
4" SDR -35 PVC PERFORATED
LATERAL INSTALLED NEAR
LEVEL, IN BED CONFIGURATION
LIMIT OF 10'x25'
STONE BED
PROPOSED 500 GALLON PRECAST CONCRETE PUMP STATION
SEPTIC TANK DETAIL
NTS
NTS
4" MINIMUM TOPSOIL ON
ENTIRE BACKFILL AREA;
SEED AND ESTABLISH TURF
25' BED
LENGTH
ABSORPTION BED PROFILE
4" PERFORATED PVC LATERALS
INSTALLED NEAR LEVEL IN
BED CONFIGURATION
— 25' —
ABSORPTION BED PLAN
APPROXIMATE
EXISTING GRADE
FILTER FABRIC,
TENCATE MIRAFI 140N
OR EQUIVALENT
PROPOSED
DISTRIBUTION BOX
TRANSITION FORCE
MAIN TO 4" PVC
OUTSIDE OF D—BOX
EXTERIOR WEATHERPROOF JUNCTION BOX
(IF NECESSARY). SEAL CONDUIT GAS TIGHT.
INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL
WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL
INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION
12" MIN. COVER
DISTRIBUTION BOX
TRANSITION TO
4" PVC OUTSIDE
OF D—BOX
2"MIN
2"MIN. DROP
BETWEEN INVERT
PUMP STATION NOTES
EFFLUENT PUMP SEAL ALL TANK OPENINGS WATERTIGHT.
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP
CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM.
INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL
INSIDE HOUSE IN ACCESSIBLE LOCATION.
INSTALL POWER & CONTROL WIRING TO CONTROLLER
WITH ALARM IN HOUSE IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS AND NATIONAL
ELECTRIC CODE (N.E.C.) REQUIREMENTS.
PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED
TO PROVIDE A 50 GALLON DOSE.
PUMP TO BE GOULDS MODEL 3885, WE0512H 230V,
SINGLE PHASE, 35 GPM PUMP AT 30 FT TDH.
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO
PURCHASING PUMP.
WASTEWATER SYSTEM DESIGN
2—BEDROOM RESIDENCE
DESIGN FLOW — 110 GPD/BEDROOM
SYSTEM DESIGN FLOW — 220 GPD
SEPTIC TANK — 1000 GAL PRECAST CONCRETE
PUMP STATION — 1000 GAL PRECAST CONCRETE
ABSORPTION BED AREA REO'D = (220 GPD)/(.95 GPD/SF)
= 232 SF
ABSORPTION BED AREA PROVIDED = 10'x25' = 250 SF
APPLICA71ON RATE TO EXISTING SOIL: .95 GPD/SF, BASED ON
1-5 MIN/IN PERCOLATION RATE
POTABLE WATER SUPPLY —
EXISTING LAKE WATER INTAKE TO BE REPLACED BY WELL
SITE SOILS DATA
TEST PIT
TP -1 — 4/9/15 BY T. HUTCHINS, P.E.
0-6" — TOPSOIL
6-16" — BROWN LOAMY FINE SAND
16-35" — RED—BROWN FINE SANDY LOAM
109 COBBLES & BOULDERS
35-60" — LIGHT BROWN FINE SAND, SOME SILT
60-72" - MEDIUM BROWN COARSE SAND
NO SEASONAL HIGH GROUNDWATER EVIDENCE
SYSTEM MATERIAL SPECIFICATIONS
EFFLUENT FILTER
EFFLUENT FILTER TO BE INSTALLED AS SANITARY TEE ON OUTLET PIPE
FROM SEPTIC TANK TO PUMP STATION TO BE AN EFFLUENT FILTER
WITH 1/16—INCH FILTRATION, POLYLOK PL -122.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCH-40 PVC. INSTALL WITH 1/8"
PER FOOT MINIMUM SLOPE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON—WOVEN SEPARATION FABRIC,
TENCATE MIRAFI 140N OR EQUIVALENT.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/4" PER FOOT MINIMUM SLOPE.
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE.
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED
MULCH, AND ESTABLISH TURF.
TONIN OF Q
BUILDING &
Reviewed B)
Date: �—
Dig %Safely.
MAP REFERENCE
SUGGESTED: INSTALL POLYLOK
BASE SURVEY INFORMATION
TAKEN FROM:
E Cali Before You Dig
12" MIN.
PL -122 FILTER SUCH THAT IT IS
INSTALL FLOAT SWITCHES TO OPERATE
SCHMIDT - DATED MAY 16,
2013, LAST
COVER
READILY REMOVABLE THROUGH
PUMP AND MAINTAIN LEVELS AS INDICATED
® Dig With care
800.962.7962
VAN DUSEN & STEVES LAND SURVEYORS,
srww.dlasafelynewyork.eom
TANK ACCESS COVER
0
ISSUED FOR PERMIT
a
1/8" PER FOOT
No.
Q
2"
O
MIN. SLOPEno _
INSTALL VALVE AND UNION--
SLA��
E -0 U7
Scale: NOTED
OUTLET 4'" PVC SDR -35
SUCH THAT PUMP CAN BE
V N M
c c
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL
LIQUID LEVEL
ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.
ISOLATED AND REMOVED
NNN
WITHOUT REQUIRING PIT ENTRY
18"
16"
MIN.
°
ALARM 3" ABOVE
2 k
'PUMP ON'
o:
FLOAT SWITCHES — INSTALL INSIDE
o o
PUMP ON
PUMP PIT IN LOCATION ACCESSIBLE
WITHOUT P17 ENTRY
o
PUMP OFF
MINIMUM 2X WIDTH
_
° e
SEPTIC TANK NOTES
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE
DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS
MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT.
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE.
WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE A STABLE BASE.
SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY
CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING.
ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID
LEVEL MUST BE TESTED BEFORE BACKFILLING.
16" MIN
APPROXIMATE
EXISTING GRADE
10' BED WIDTH
4" MINIMUM TOPSOIL ON
ENTIRE BACKFILL AREA;
SEED AND ESTABLISH TURF
BACKFILL MATERIAL AS NEEDED \-10'x25' CRUSHED STONE
TO ESTABLISH GRADES ABSORPTION BED
ABSORPTION BED SECTION
4" SDR -35 PVC PERFORATED
LATERAL INSTALLED NEAR
LEVEL, IN BED CONFIGURATION
LIMIT OF 10'x25'
STONE BED
PROPOSED 500 GALLON PRECAST CONCRETE PUMP STATION
SEPTIC TANK DETAIL
NTS
NTS
4" MINIMUM TOPSOIL ON
ENTIRE BACKFILL AREA;
SEED AND ESTABLISH TURF
25' BED
LENGTH
ABSORPTION BED PROFILE
4" PERFORATED PVC LATERALS
INSTALLED NEAR LEVEL IN
BED CONFIGURATION
— 25' —
ABSORPTION BED PLAN
APPROXIMATE
EXISTING GRADE
FILTER FABRIC,
TENCATE MIRAFI 140N
OR EQUIVALENT
PROPOSED
DISTRIBUTION BOX
TRANSITION FORCE
MAIN TO 4" PVC
OUTSIDE OF D—BOX
EXTERIOR WEATHERPROOF JUNCTION BOX
(IF NECESSARY). SEAL CONDUIT GAS TIGHT.
INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL
WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL
INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION
12" MIN. COVER
DISTRIBUTION BOX
TRANSITION TO
4" PVC OUTSIDE
OF D—BOX
2"MIN
2"MIN. DROP
BETWEEN INVERT
PUMP STATION NOTES
EFFLUENT PUMP SEAL ALL TANK OPENINGS WATERTIGHT.
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP
CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM.
INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL
INSIDE HOUSE IN ACCESSIBLE LOCATION.
INSTALL POWER & CONTROL WIRING TO CONTROLLER
WITH ALARM IN HOUSE IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS AND NATIONAL
ELECTRIC CODE (N.E.C.) REQUIREMENTS.
PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED
TO PROVIDE A 50 GALLON DOSE.
PUMP TO BE GOULDS MODEL 3885, WE0512H 230V,
SINGLE PHASE, 35 GPM PUMP AT 30 FT TDH.
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO
PURCHASING PUMP.
WASTEWATER SYSTEM DESIGN
2—BEDROOM RESIDENCE
DESIGN FLOW — 110 GPD/BEDROOM
SYSTEM DESIGN FLOW — 220 GPD
SEPTIC TANK — 1000 GAL PRECAST CONCRETE
PUMP STATION — 1000 GAL PRECAST CONCRETE
ABSORPTION BED AREA REO'D = (220 GPD)/(.95 GPD/SF)
= 232 SF
ABSORPTION BED AREA PROVIDED = 10'x25' = 250 SF
APPLICA71ON RATE TO EXISTING SOIL: .95 GPD/SF, BASED ON
1-5 MIN/IN PERCOLATION RATE
POTABLE WATER SUPPLY —
EXISTING LAKE WATER INTAKE TO BE REPLACED BY WELL
SITE SOILS DATA
TEST PIT
TP -1 — 4/9/15 BY T. HUTCHINS, P.E.
0-6" — TOPSOIL
6-16" — BROWN LOAMY FINE SAND
16-35" — RED—BROWN FINE SANDY LOAM
109 COBBLES & BOULDERS
35-60" — LIGHT BROWN FINE SAND, SOME SILT
60-72" - MEDIUM BROWN COARSE SAND
NO SEASONAL HIGH GROUNDWATER EVIDENCE
SYSTEM MATERIAL SPECIFICATIONS
EFFLUENT FILTER
EFFLUENT FILTER TO BE INSTALLED AS SANITARY TEE ON OUTLET PIPE
FROM SEPTIC TANK TO PUMP STATION TO BE AN EFFLUENT FILTER
WITH 1/16—INCH FILTRATION, POLYLOK PL -122.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCH-40 PVC. INSTALL WITH 1/8"
PER FOOT MINIMUM SLOPE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON—WOVEN SEPARATION FABRIC,
TENCATE MIRAFI 140N OR EQUIVALENT.
HOUSE SEWER PIPE
PIPING TO BE 4" SDR -35 OR SCHEDULE 40 PVC. INSTALL WITH
1/4" PER FOOT MINIMUM SLOPE.
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE.
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED
MULCH, AND ESTABLISH TURF.
TONIN OF Q
BUILDING &
Reviewed B)
Date: �—
Dig %Safely.
MAP REFERENCE
New/York
BASE SURVEY INFORMATION
TAKEN FROM:
E Cali Before You Dig
"MAP OF A SURVEY MADE
FOR WENDY
IN Wait The Required Time
SCHMIDT - DATED MAY 16,
2013, LAST
IM Confirm Utility Response
® Respect The Marks
REVISED JANUARY 8, 2014,
PREPARED BY.•
® Dig With care
800.962.7962
VAN DUSEN & STEVES LAND SURVEYORS,
srww.dlasafelynewyork.eom
QUEENsevlzY, NY
LOCATION MAP
LOCATION
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN
ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL
HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF
THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK
LEACH FIELDS.
AFTER EXCAVATION OF 10' WIDE ABSORPTION BED TO THE DEPTHS
REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED
IN ORDER TO LOOSEN SMEARED AREAS OF SOIL.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER
FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO
AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN
THE STONE AND PIPE.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING
STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED
JOINTS, OR OTHER UNSUITABLE CONDITIONS. PIPE SHALL BE LAID
WITH HOLES DOWN IN ALL CASES.
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND
DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN THE ASSORP77ON AREA
AFTER PIPING HAS BEEN INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED
BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES
AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS
NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES,
SUCH AS JACUZZI—TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT. THE INSTALLATION OF NON—CONSERVING WATER
FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE
APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM.
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE
MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO
DIVERT SURFACE RUNOFF AROUND ABSORP77ON FIELD.
N
H
ILE :C :0P
JYCD
CF
O
* �
N
cc
CN
W
Ul
O
[Y] Z
0
ISSUED FOR PERMIT
5/29/2015
No.
Q
p� 6
O
e F. -
+U—.
CL
SLA��
E -0 U7
Scale: NOTED
Date:
TAX MAP # 279.17-2-28
V N M
c c
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL
N
ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.
NNN
0
ISSUED FOR PERMIT
5/29/2015
No.
Revisions
Date
WASTEWATER SYSTEM PLAN
prepared for.
Wendy Schmidt
72 Sunnyside Road North
Town of Queensbury, Warren County, NY
Drawn: GTH
Checked: LIND
Scale: NOTED
Date:
10/24/2014
169 Haviland Road
N
Queensbury, NY 12804
(518) 745-0307 Phone
Hutchins Engineering s1s 745-0308 Fax
29857-01