Loading...
CC-000156-2015 TOWN OF QUEENSBURY 742 Bay Road, Queensbury,NY 12804-5904 (518)761-8201 -- .4 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000 1 5 6-20 1 5 Date Issued: Monday, November 23, 2015 This is to certify that work requested to be done as shown by Permit Number CC-000156-2015 has been completed. Tax Map Number: 288.12-1-15 Location: 1496 State Route 9 Owner: Lake George Associates Applicant: Bast Hatfield LLC This structure may be occupied as a: Commerical Alterations 1700 s.f Sox Market By Order of Town Board TOWN OF QUEE SBURY Issuance of this Certificate of Occupancy DOES NOT relieve theP 4 P Y property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. T©" OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: CC-000156.2015 e>f' 2C 15—16S Tax Map No: 288.12-1-15 Permission is hereby granted to: Bast Hatfield LLC REVISED For property located at: 1496 State Route 9 In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name:. Lake George Associates Retail-Mercantile-Alteration $68,000.00 Owner Address: 50 State ST,6th Floor Total Value $68,000.00 Albany,NY 12207 Contractor or Builder's Name/Address Electrical Inspection Agency Bast Hatfield LLC 1399 Vischers Ferry RD Clifton Park,NY 12065 Plans& Specifications PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday,June 3, 2016 (if a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before tex/pf ratt Dated at the Town of Que ury; ��f 1N ay,June 3, 2015 SIGNED BY: V for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION_. Office Use Only !1 - Received Date: MAY 2/ ZD/ � Tax Map ID 7-68 - 1 Z, 1-15 Tax Map ID Ill MAY 2 1 2015 Permit No. Z.01 -165 Permit Fee Zone OWN OF OUEENSBUF„ Rec Fee Historic Site Yes N. BUJLDING& CODES Site Plan# Subdivision Name Lot# Subdivision# TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS - SINGLE FAMILY, DUPLEXES/TWO-FAMILY, MULTIPLE FAMILY, APARTMENTS, CONDOMINIMUMS, TOWNHOUSES,AND/OR MANUFACTURED&MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. Iggb Applicant ,gAs) /tif ig c?al CansZr4b7:0^wner Lt)( Gcorq e Oath's .CSC: Address /399 �' 2t Yisc4ree Address �/ Fceicy Ad- 60 3iap c St. ‘t/►�/oeY Cl,:3z/0"J 5/.9.eK NY/2465- A 16/9NY /lY /Zzo7 Phone/E-mail 7`/ "14:e6 '37'44°74'1 i co^' Phone/E-mail z Fdl a3" 5/8-37.7-200C1 dwvodrAyg jorderlclae/apyr ri-- r // Contact Contact Person for Building&Codes Compliance: 27,10"74,g 77R-0,72/Ce Phone 5/8-- TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1st floor sf 2'floor sf Total sf Height Single Family Two-Family Multi-Family (#of units ) Townhouse Business Office Retail -Mercantile 1v‘ ;py✓ V /1'00 SF Factory- Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 • If commercial or industrial please indicate of business y-G2/4, 1 5 7?a rG Proposed use of building or addition y.c..--2-ek;j 31-ere- Source of Heat (circle one) Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances& Chimneys WH Are there structures not shown on plot plan? NlA Are there easements on the property? AffA Site Information a. Dimensions or acreage of lot b. Is this a corner lot? c. Will the grade be changed as a result of construction Yes No d. Public water or Private well e. Sewer or Private Septic System Value of all work to be performed(labor or materials) $ 6 8,466. o0 DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application,plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: %do w s GT AA,2�ico DATE: 3 Zl•/S SIGNATURE: # 4fDATE: 5-%//%5" //%5 For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 1-3 Rough Plumbing 1 Insulation Inspection Report Inspection request received SI, - J —c Name �� vv Inspected on 63i'5 1 ZQ,It`Z Location Izi,1 � ,/te., ,Ll I Arrive V:�_ j /pmt Permit No. I r5- 18'3 Inspector's Initials Type of Structure 0 �\en Z \ .;C&.--c---*► t Dt7 COMMENTS "' Y NA jgAnn 'Plumbingunderslab (5'D-1- `"'1153L Rough Plumbing /Nail Plates Plumbing Vent / Vents in Place ,/ ---- f 1 %: inch minimum Drain Size 1( 1'� 1)acci) Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction / 1 _ ��� � ---' Pressure Test V Drain /Vent iii Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes IV) Pressure Test Water Supply Piping Air / Head .� 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent.Attic Vent Door / Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly /No duct tape Blower Door Test Air Sealing Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 4 Rough Plumbing I Insulation Inspection Report Inspection request received 6`Z'}-\2ADA5 Name Y Malt , Inspected on 81 2 2Q�S Location ' 616 Arrive A le„*" Permit No. 15-- I Inspector's Initials Type of Structure C,c1 C ea, ENTS Y N NA Plumbing under slab Rough Plumbing / Nail Plates Plumbing Vent /Vents in Place 1 Yz inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes � 1. Insulation / Residential Check/ Commercial Check 2)15 V r�✓ Window Sealing Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape Blower Door Test Air Sealing *\Vim. Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 1 Town of Queensbury Building & Code Enforcement L': Office No. (518) 761-8256 at' 11 1 Framing I Firestopping Inspection Report Inspection request received: 61(012-Q-6 Name: dk.Lr Inspected on: k ' Location: j z f l ' Stk,k.12-0,LiK° Arrive: `-�r7► � .m. Permit No.: \S' IoS Inspector's Initials: 4111.5 TYPE OF STRUCTURE: C!JVyV\ • / Y N NIA COMMENTS: Framing QrPt-L . Attic Access 22"x 30"minimum Jack Studs/Headers Ciek 1y- Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. V Headroom 6 ft.8 in. t F Q'� n Stairwells 36 in.or more J Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required g)Framing/Firestopping Inspection Report 5EGURITY/ TELEGOMMUNIGATIQN5 DATA 5y5mm. i5Y5TEM5 BY TENANT) I. THE TENANTS SECURITY/ TELECOMMUNICATIONS/ DATA CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK ON- ALL OTHER TRADES. 2. ALL WIRIN6 SHALL BE CONGEALED ABOYE GEILIN65, OR WITHIN WALLS UNLESS OTHERWISE NOTED. ALL EXP05ED WIR:N& 5FALL_ BE LOCATED 50 THAT IT 15 OUT OF VIEW A5 MUCH A5 POSSIBLE. ALL EXPOSED WIRING SHALL BE DONE IN THE NFATE3T AND M05T ORDERLY FA514I0N 3. PENETRATIONS THROUGH NEW OR EXI5TIN6 FIRE RATED WALL5, 5MOKE PARTITIONS AND FLOORS, SHALL BE MADE FIRE AND SMOKE TI6HT IN AGGORDANGE WITH THE FIRE AND BUILDING CODES OF NEW YORK STATE BY THE TELECOMMUNICATIONS/ DATA SYSTEM CONTRACTOR. 4. ALL SECURITY/ TELECOMMUNICATIONS/ DATA SYSTEMS SHALL BE DE-516NED AND PROVIDED BY THE 5EGURITY/ TELEGOMMUNIGATIOI DATA 5Y5TEM5 CONTRAZ?O45 ENGINEER IN AGGO VANGE WITH THE NEG AND ALL OTHER APPLICABLE CODES (SEE CODES, PERMITS AND IN51FEGTION5 THIS SHEET). THE ENGINEER. AND GONTRAGTOR 514ALL COORDINATE DESIGN WITH THE FIRE ALARM SYSTEM ELECTRICAL EN61NEER AND ELEVATOR SUPPLIER 5. ALL GROUNDING SHALL BE PROVIDED AS REQUIRED BY THE NEC,. 6. THE SECURITY/ TELEGOMMUNIGATION5/ DATA SYSTEMS CONTRACTOR SHALL NOT ATTACH ANY WIRING TO SPRINKLER PIPING (IF APPLIGABLE). 7. THE 5EGURITY/ TT:LECOMMI NIGATION5/ DATA CONTRACTOR SHALL PROVIDE AN INSURANCE GERTIFICATE THAT MEETS THE TENANTS NEEDS. 5EGURITY/ TELEGOMMUNIGATIONS/ DATA itiIATERIAL5: I. THE 5E0IRITY/ TELEGOMMUNIGATION5/ DATA SYSTEM CONTRACTOR AND OWNER SHALL BE RESPON515LE FOR THE SPECIFICATION OF ALL SECURITY/ TELEG",UNIGAT10N5/ DATA SYSTEM MATERIALS AND FIXTURE5 NOT SPEGIFIGALLY NOTED ON TE5E DRAWINGS. THE SECURITY/ TELECOMMUNICATIONS/ DATA SYSTEM CONTRACTOR SHALL SUBMIT GATALO6 CUT5 ON ALL 5EC )RITY/ TELEGOMMUNIGATIONS/ DA rA 5YST'EM MATERIALS TO THE OWNER FOR APPROVAL PRIOR TO ORDERING. PLUMBING 5Y5TEM5: 1. THE PLUMBIN& CONTRACTORS NEW YORK 5TATE LICENSED PROFESSIONAL ENGINEER SHALL DESIGN THE PWMBING SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE CODES (SEE GODE5, PERMITS AND I145PEGTION5 THIS SHEET). IF REQUIRED BY fiLE0W :Y,IIY THE EN61NEER. SHALL PROVIDE 516NED AND SEALED CONSTRUCTION DOCUMENTS TO THE BUILDING 12EPARTTMENT FOR BUILDING PERMIT. 2. ALL NEW PIPING SHALL_ BE CONGEALED ABOVE CEILIN165, BELOW FLOOR 5LAE35 OR WITHIN WALL5 UNLESS OTHERWISE NOTED. ALL EXPOSED PIFIN6 SHALL BE LOCATED 50 THAT IT 15 OUT OF VIEW A5 MUCH A5 P0551BLE. ANY EXPOSED PIPIN6 SHALL BE DONE IN THE NEATEST AND M05T ORDERLY FASHION. 3. PENETRATIONS THROUGH NEW OR EXI5TIN6 FIRE RATED WALLS, 51-.9KZ- PARTITIONS AND FLOORS, SHALL BE MADE FIRE AND SMOKE TIGHT IN ACCORDANCE WITH THE FIRE AND BUILDING CODES OF NEW YORK STATE BY THE PLUMBING GONTRAGTOR. 4. PROVIDE TRAPS, DIRT LEGS, PIPING INSULATION, EQUIPMENT &A5 SHUT OFFS, BACK FLOW PREVENTERS, INDIREGT WASTE CONNECTIONS, ETG., AS REQUIRED BY THE PLUMBING CODE OF N.Y.S. AND ENERGY CONSERVATION CONSTRUCTION CODE OF N.Y.S.. 5. THE PLUMBING GONTRAGTOR SHALL PROVIDE AN INSURANCE CERTIFICATE THAT MEET5 THE OWNERS NEEDS. PLUMBING MATERIAL5: I. THE PLUMBING CONTRACTOR AND/OR GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SPECIFIGATION OF ALL PL.UMBIN6 MATERIALS NOT SPECIFICALLY NOTED ON THESE DRAWINGS. THE PLUMBING CONTRACTOR SHALL SUBMIT CATAL06 GUTS ON ALL PLUMBIW6 MATERIALS TO THE GENERAL CONTRACTOR FOR APPROVAL PRIOR TO ORDERING. ALL ABOVE GROUND PIPE TO BE HJBLE55 CAST IRON, COPPER OR SCHEDULE 40 PVC. PVC 15 NOT PERMITTED IN ANY AIR PLENUMS. ALL BELOW GRADE SANITARY PIPE TO BE GAST IRON. ALL POTABLE WATER SUPPLY PIPIN6 TO BE COPPER. ALL DOMESTIC SPRINKLER PIPIN6 TO BE SCHEDULE 40 STEEL PIPIN6. ALL PLUMBING MUST COMPLY WITH NEW YORK STATE GODE5 FOR MATERIAL AND WORKMANSHIP. ALL PIPING TO BE TESTED. ALL SUPPLY PIPIN6 TO BT_ INSULATED. ALL DOMESTIC PIPIN6 TO BE SANITIZED AND TESTER ELEGTRIGAL 515TEM5: I. THE ELECTRIGAL SERVICE 15 EXI5TIN6. THE GENERAL GONTRACTOR'5 LICENSED ELECTRICAL EN61NEER SHALL DE -516N AND PROVIDE THE EXTENSION OF THE EXISTING SYSTEMS IN AGGORDANGE WITH ALL APPLICABLE CODES, INGLUDI% THE NFPA NEC AND NY5 BUILDING CODE FAMILY OF 2010. 2. THE ELEGTRIGAL CONTRACTOR SHALL GOORDINATE H15 WORK WITH THE WORK OF ALL OTHER TRADES. 3. ALL WIRING SHALL BE GONGEALED ABOVE GEILIN65, OR WITHIN WALL5 UNLE55 OTHERWISE NOTED. ALL EXP05ED WIRING 544ALL BE LOCATED 50 THAT IT 15 OUT OF VIEW A5 MUGH A5 POSSIBLE. ALL EXPOSED WIRING SHALL BE DONE IN THE NEATEST AND MOST ORDERLY FASHION. 4. &ROUND FAULT OUTLETS MUST BE PROVIDED FOR ALL OUTLETS WITHIN 5 FEET OF A PLUMBING FIXTUf; E OR WATER SOURCE. (PER KEG). 5. PENETRATIONS THP.OUSH NEK OR M5TIN6 FIRE RATED WALLS, SMOKE PARTITIONS AND FLOORS SHALL BE MADE FIRE AND SMOKE T6HT IN AGGORDANGE WITH THE INTERNATIONAL FIRE AND BUILDIN6 CODES BY THE ELECTRICAL CONTRACTOR. b. ALL ELECTRIGAL WORK SHALL BE PROVIDED BY A LICENSED ELECTRICIAN. 7. ALL NEW LI6HTIN6, RECEPTACLES AND GIRGUITI% SHALL BE DF516NED BY THE GENERAL GONTRAGTORS OR ELECTRICAL CONTRACTORS NEW YORK LICENSED ELECTRICAL EN61NEER AND SHALL BE PROVIDED BY THE ELEGTRIGAL GONTRACTOR IN AGGORDANGE WITH THE NEC, AND ALL OTHER APPLIGABLE CODES (SEE GODE5, PI AND INSPECTIONS ABOVE). THE EN61NEER SHALL PROVIDE SIGNED AND SEALED CO%TRIUGTION DOCUMENTS TO THE BUILDING DEPARTMENT FOR BUILDING PERMIT. THE ELEGTRIGAL ENGINEER SHALL 065ERVE THE GONI51RLIGTION PROC-RE55 AND SHALL PROVIDE THE ARCHITECT WITH A GOMPLETION LETTER AT THE END OF THE PRO.EGT 5TATIN6 THAT THE WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. 8. LIGHTING FIXTURES SHALL BE HUNG WITH WIRE. q. ALL GROUNDING SHALL BE PROVIDED AS REQUIRED BY THE NEG. 10. THE ELECTRICAL GONTRAGTOR SHALL NOT ATTACH, HA% OR OTHHERK15E CONNECT ANY LI&HTIN6 FIXTURES, GABLE OR WIRING TO SPRINKLER PIPING (IF APPLICABLE). IL IF THE SPACE ABOVE THE GEILIN6 15 BEIN6 USED FOR RETURN AIR FOR THE HVAC SYSTEM, ALL WIRING IN THIS SPACE SHALL BE PLENUM RATED IN AGGORDANGE WITH THE NEG_ 12. WIRING 15 NOT PERMITTED TO 13E PLACED ON THE GEILI% GRID. ELEGTRIGAL MATERIALS: I. ALL WIRE CONDUCTORS SHALL BE COPPER. 2. ALL WIRIN6 SHALL BE RUN IN GALVANIZED STEEL CONDUIT, EMT CONDUIT, MG GABLE OR A5 APPROVED BY THE NEG. 3. THE GENERAL CONTRACTOR AND FJEGTRICAL CONRAGTOR SHALL BE RESPONSIBLE FOR THE 51FELIFICATION OF ALL ELECTRICAL MATERIALS AND FIXTURES NOT SPECIFICALLY NOTED ON THESE DRAWI1495. THE ELEGTRICAL CONTRACTOR SHALL SUBMIT GATAL06 CUTS ON ALL ELECTRICAL MATERIALS AND L16HTIN6 FIXTURES TO THE GENERAL CONTRACTOR AND ELPGTRICAL ENGINEER FOR APPROVAL PRIOR TO ORDERIN6. HVAG 515TEM: I. THE WAG GONTRALTORS NY5 LICENSED PROFESSIONAL ENGINEER SHALL DL516N THE WAG SYSTEM MODIFICATIONS IN ACCORDANCE WITH THE BUILDING CODE FAMILY OF NY5 (INCLUDING SEISMIC REQUIREMENITS), MEGHANIGAL CODE OF NEW YORK STATE, A5HRAE STANDARDS AND ALL APPLIGABLE GODES (SEE GODES, PERMITS AND INSPEGTIONLS ABOVE). VENTILATION SHALL BE PROVIDED IN ACCORDANCE WITH THE MECHANICAL (ADE OF NEW YORK STATE, A54RAE STANDARDS AMD ALL APPLICABLE CODES (SEE CODES, PERMITS AND IN5PEGTIO% ABOVE) THE WAG DE516NER SHALL GOORDINATE THE INSTALLATION OF ALL EQUIPMENT, DIUGTWORK, ETG. WITH L16HTIN6 FIXTURE -5, FIR'_ ALARM SYSTEM, BUILDING 5TRUGTURE, ETG. AND SHALL INFORM THE ARG 11TELT IN ADVANCE OF ANY CONSTRUCTION GONFLIGTS. IF REQUIRED BY THE Qll'Y,NY BUILDING DEPARTMENT, THE ENGINEER SHALL. PROVIDE 516NED AND SEALED CONSTRUCTION DOCUMENTS TO THE BUILDIN6 DEPARTMENT FOR BUILDING PERMIT. THE WAG ENGINEER SHALL OBSERVE THE GONSTRUGTION PR06RE% AND SHALL PROVIDE THE ARCHITECT WITH A GOMPLETION LETTER AT THE END OF THE PROJECT 5TATIND6 THAT THE WORK HAS BEEN GOMPLETED IN ACCORDANCE WITH HIS GONLSTRUGTION DOCUMENTS. 2. ALL *A DUCT WORK AND PIPIN6 SHALL BE CONGEALED ABOVE CEILIN65, WITHIN FLOORS, OR WITHIN WALLS UNLESS OTiERW15E NOTED. 3. PENETRATIONS 7HRGU5H NEW OR EXI5TIN5 FIRE RATED WALLS, 5MOKE PARTITIONS, 5U5PENDED ACOUSTICAL TILE GEILIN6 SYSTEM AND ALL FLOORS SHALL BE SEALED WITH UL APPROVED MATERIALS AND METHODS AND MADE FIRE AND SMOKE TIGHT. FIRE DAMPERS SHALL BE PROVIDED WHERE REQUIRED BY THE MEGHANIGAL CODE OF NEW YORK STATE. 4. THE WAG CONTRACTOR SHALL COORDINATE HI5 WORK WITH THE WORK OF ALL OTHER TRADE5. 5. PROVIDE A BALANCING SYSTEM AS REQUIRED 13Y THE ENERGY CODE OF NY5 b. THE SPACE ABOVE THE GEILIN6 15 BEING USED FOR THE HVAC RI=TURN AIR. THE WAG GONTRAGTOR SHALL USE THE PROPER MATERIALS AND METHODS IN AGCARDANGE WITH THE NEG. WIRE 15 NOT ALLOWED TO BE LAYFD ON TOP OF THE SUSPENDED AGOUSTIGAL TILE GEILIN& GRID. HVAC M6TE1;ZI6L5: I. THE HVAC, CONTRACTOR AND THE GENERAL GONTRACTOR SHALL BE RE5PON5IELE FOR THE SPECIFICATION OF ALL WAG MATERIALS NOT SPEGIFIGALLY NOTED ON THESE DRANN65. THE HVAG CONTRACTOR SHALL SUBMIT GATAL06 GUT5 ON ALL HVAC MATERIALS TO THE GENERAL GONTRAGTOR FOR APPROVAL PRIOR TO ORDERING. 2. THE HVAC CONTRACTOR SHALL NOT ATTACH, HAN6 OR OTHERWISE GONNGT ANY DUCTWORK OR ANY RELATED SYSTEM CONTROLS TO SPRINKLER PIPING, PLUMBING LINlE5 OR El EGTRIGAL CONDUIT. AL, AGOU6TICAL CEILING EDL. EVERY OTHER COURSE HR HOUR R.R. REST ROOM ALP. AUIMINIM COMPOSITE PANEL EQ. EQUAL NELL. INSULATED or INSULATION 5A.T. 9U51PENDED AG0U5TIGAL TILE AL.T. AGAYTICAL GEILIN6 TILE EQUIP. EQUIPMEHr INT. INTERIOR 5GED SCAV ULE ADA AMERICANS WITH DISABILITIES ACT EA EACH WAY L.L.V. LON5 LE5 VERTICAL 5LW. SOLID GORE WOOD AFF. ABOVE FINI5FED FLOOR EX FXI5TIN6 M. MIRROR 5D. SOAP DI5PEFSER AL. ALLMINUM EXIST. EXI5TIN6 MA5. MASONRY 5.RFEG. 5EMI-REGE55EV FIRE ALUM. ALUMINRM EXI5T'6 EXI5TIN6 MAX. MAXIMUM EXTINSJ15HER CABINET ANSI AMERIGAN NATIONAL STANDARDS EXT. EXTERIOR MET. METAL SIM. SIMILAR INSTITUTE F/ FARE OF MIN. MINIMUM 5TL. STEEL BOT. BOTTOM F.D. FLOOR DRAIN MD. MASONRY OPE NINE T. or T/ TOP G. CARPET EDN. FOUNDATION MTL META- TBR TO BE REMOVED GB COVE BASE FEL. FIRE EXTINIGUI511 CABINET N.FPA. NATIONAL FIRE PROTECTION THK. TNGK (NII GDT. CONDUIT Fb. FULL 6LA55 ASSOCIATION T.P. TOILET PAPER DISPENSER L.J. GONTROL JOINT FIN FINISH (ED) N.T.S. INTO TO SCALE T.R. TO REMAIN GLC. II FI FLOOR N.Y.S. NEW YORK STATE T5. FLOOR TRANSITION STRIP GLR. CLEAR FIND. FEMININE NAPKIN DISPENSER OL. ON GENTER TYR TYPIGAL GO. CLEAN OUT FNDN. FOLWATION OD. OUTSIDE DIAMETER U.L. UNDERWRITERS LABORATORIES ING. G.T. GERAMIG TLE 5.RFEG. FULLY REGE55ED FIRE OM OVERHEAD UNA. U14LEE5 NOTED O HE RASE G.M11. CONCRETE MASONRY UNIT EXTINGUISHER CABINET O.H. OVERHEAD UDIL VA -E95 OTHERWISE NOTED LONG. - CONCRETE F.S. FLOOR STOP 0/0 Our TO OUT VB. VAPOR BARRIER GON5TN C0N511 IKTION FT. FOOT or FEET 05NA OCCUPATIONAL SAFETY AND VLB. VINYL COVE BASE DONT. GONTINU0115 6A 6A06E HEALTH ADMINISTRATION VL.T. VINYL COMPOSITION TILE GONTTR CONTRAGTOR 6A.V. 6ALVAN12EJ P. PAINT VERT. VERTICAL DEPT. DEPARTMENT 6B. 6RAB BAR PEE. PRE-EN61NEERED BUILDIN6 IN WITH DET. DETAIL 6L. CLASS PF PRE -FINISHED K.B. WALL Bu MPGR DIA. DIAMETER LIAR 6YP5UM WALLBOARD PL PLASTIC, LAMINATE WG MIR GL05ET DLA. DAY LIGHT OPENING HGP. HANDICAP (PED) P.T. PRE55LIRE TREATED WD' WOOD OR, DOOR HLA HOLLOW GORE WOOD P.TDAWK PAPER TONEL DISPENSER WH. WATER NEATER DNC. DRAWING HD. HEAT DETECTOR AND WASTE WH.M. WELDED HOLLOW METAL E.IF5. EXT. IN15uLATEV FIN. SYSTEM HOYE. HARDWARE P.V.G. POLYVINYL CHLORIDE NIL. WALL ELB1. aEGTTRIG ar ELEGTRIGAL H.M. HOLLOW METAL RD. ROOF DRAIN W.M. WATER MIE B ELEV. ELEVATION HOR. HORIZONTAL RM. ROOM EM. ENTRANCE MAT INC R.O. ROUGH OPBNIN6 GENERAL NOTE - 5 -1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL METHODS AND MEANS OF CON5TRUGTION AND SHALL BE RE5PONSIBLE TO THE OWNER AND OCQIPANT5 FOR PROVIDING A SAFE WORK ENVIRONMENT DIXRINC7 THE CONSTRUCTION PERIOD. 2. ALL MATERIALS SHALL BE INSTALLED IN AGGORDANGE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS AND REGOMMENDATION5. 3. DIMENSIONS AND DETAILS ARE BASED ON THE BEST AVAILABLE INFORMATION AND THE GONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIELD DIMENSIONS BEFORE ORDERING MATERIALS AND PREFABRICATED ITEMS 4. THE GONTRAGTOR SHALL BE RESPONSIBLE FOR MAINTAINING A GLEAN WORK SITE AT ALL TIMES. TH15 INCLUDES THE REMOVAL OF ALL TRASH AND GONSTRUCTION DEBRIS ON A DAILY BASIS. 5. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY hF%HANICS SKILLED IN THEIR RESPECTIVE TRADE5. 6. ALL INTERIOR DIMENSIONS ON THE DRAHN&5 ARE TO THE CENTERLINE OF WALL OR FAZE OF 6YPSUM WALLBOARD UNLESS NOTED OTHERWISE. 7. THE CONTRACTOR SHALL BE RE5PON51BLE FOR INSPEGTIN6 AND CORREGTIN& HIS OWN WORKMANSHIP TO THE EXTENT THAT SATISFIES THE TENANT. 8. THE CONTRACTOR AND TENANT SHALL BE RESPONSIBLE 7 -OR SPECIFICATIONS OF ALL MATERIALS NOT SPECIFIED ON THE DRANN65. THE CONTRACTOR SHALL GOORDINATE THE SELECTION OF ALL COMPONENT GOLORS, MODEL NVMBER5, 51ZE5, ETC. OF ALL BUILDIN6 =1 EMENT5 WITH THE TENANT BEFORE ORDERIN6 MATERIALS. q. ALL WORKMANSHIP AND MATERIALS, UNLESS GARRYINI6 A GUARANTEE BY A MANLIFACTU12I R FOR A LONGER PERIOD OF TIME 544ALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL PAYMENT TO THE CONTRACTOR. 10. THE CONTRACTOR SHALL VI51T THE 511E TO VERIFY FIELD SITUATIONS, NO ADDITIONAL PAYMENT WILL BE MADE FOR FAILURE TO AGGOUNT FOR OBSERVABLE CONDITIONS. IH. THROUGHOUT THE CONSTRUCTION PERIOD ALL AREAS OF THE WORK SITE SHALL BE 5EO/RED AGAINST UNAUTHORIZED ENTRY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY LOSSES DUE TO UNAUTHORIZED ACCESS TO THE WORK AREA 12. THE GONTRAGTOR SHALL MAKE EVERY EFFORT TO PREVENT THE SPREAD OF DUST, SMOKE, FUMES, ETG., THROUGHOUT THE BUILDING AND NEIGHBORHOOD. THE CONTRACTOR SHALL ERECT TEMPORARY PLASTIC, PARTITIONS, CLOSE OFF DIFFUSERS AND REGISTERS, STUFF DOOR UNIDIRGUT5, M015TIEN SAND AND GRAVEL, PROVIDE VENTILATORS, ETC., AS NECESSARY. 13. THE CONTRACTOR SHALL PREVENT HEAT L055 AND WATER INFILTRATION A5 DIGTATED BY 600D CONSTRJGTION PRACTICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY/ALL DAMAGE CAUSED BY WATER INLGL.UDI% BUT NOT LIMITED TO ROOF LEAKS, BROKEN AND/OR FROZEN PIPES, ETC. 14. THE CONTRACTOR SHALL -ROVIDE ALL TEMPORARY 519;VIGE5 INGLUDIN6, ADEQUATE LIGHTIN6, WATER, TOILETS, POWDER, FEAT, VENTILATION, M. AS REQUIRED FOR WORKMAN, MATERIAL INSTALLATION, WORK PROTECTION, ETG. 15. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE TENANTS TELEPHONE, AUDIO VI5UAL AND DATA SYSTEMS PROVIDER. 16. THE CONTRACTOR SHALL PROVIDE THE OWNER AND/OR TENANT COMPLETE MAINTENANGE AND OPERATIONAL IN5TRUCTION5 IN BOTH WRITTEN AND VERBAL FORM FOR ALL CONTRACTOR PROVIDED EQUIPMENT. 17. THE CONTRACTOR SHALL PROVIDE A THOROUGH AND PROFESSIONAL GLEANING AFTER FINAL COMPLETION OF ALL CONSTRUCTION 15 FINISHED. EXAMPLE - VACUUM AND WIPED DOWN. WAXING (NON -SLIP) FOR VGT FLOORING. 18. ALL NEW PRODUCTS, INCLUDING ADHE51VE5, SHALL BE FREE OF ASBESTOS (INGLLIDINI6, BUT NOT LIMITED TO, THE FOLLOWM6: CHRYSOTILE, CHRYSOTILE MINE -RAL FIBERS, SERPENTINE, AMONTE, GUMINOTONITE-61RUIEWTE, GROGIDOLITE, RIEBEGKITE, TREMOLITE, ANTIOPHYLITE, AGTINOLITE, CANADIAN FIBERS, ETG). THE CONTRACTOR SHALL PRUDENTLY CHECK MATERIAL SAFETY DATA SHEETS FOR ALL PRODUCTS AND VERIFY THAT THEY DO NOT INCLUDE A.PHE5T05 OR ASBESTOS GONTAININ6 MATERIALS. A. DETAILS SHOWN ARE FOR GENERAL CONDITIONS ONLY. CONTRACTOR TO COORDINATE WITH PRODUCT MANUFACTURERS WRITTEN SPEGIFIGATION5 AND INSTRUGTIONS. DETAILS MAY SHOW SELEGTED REQUIRED FASTENER TYPE, SIZES AND LOCATIONS, WHERE FASTENERS ARE DETAILED OR SCHEDULED, SUCH FA5TENIER5 SHALL NOT BE CONSIDERED A COMPLETE REPRESENTATION OF ALL FASTENERS REQUIRED, SECURE ALL WA CONSTRUCTION WITH FASTENERS OF ADEQUATE 51ZE AND AT PROPER SPAGINI6 TO INSURE THAT ALL MATERIALS WILL REMAIN SECURELY FIXED TO POSITIONS 5HOWN. PROVIDE FA5"ITNJER5 FOR EXTERIOR USES THAT ARE RE515TANT TO THE DETRIMENTAL EFFC-GT5 OF WEATHER (IE. STAINLESS STEL, 6ALVANIZED, ETG). DO NOT USE FASTENERS READILY SUBJECT TO OXIDATION. ALL FASTENERS AND FRAMING HARDWARE IN CONTACT WITH PRE55URE TREATED LUMBER TO BE HOT DIPPED 6ALVANIZED (5-185) OR TRIPLE ZING ELEGTR06ALVANIZm (GLASS RATING 40 OR ABOVE) UNLESS O1`FERN5E INDICATED ON THE DRANN65. ALL FASTENERS IN CONTACT WITH ALUMINUM AND PRE55URE TREATED LUMBER TO BE SERIES 300 5TAINLE55 STEL ('I8-8" - 18% CHROMIUM AND 8% NIGKEL). ALUMINUM SHALL_ NOT COLLIE INTO CONTACT WITH PRE55M TREATED LUMBER UNDER ANY GIRGUM5TANG£5. FASTENING OF WOOD MEMBERS SHALL MEET THE NAILING 5GHEIDULE WITHIN THE BUILDING GORE OF N.Y5. AS A MINIMUM. 20. ALL CONTRACTORS AND 51,115-CANTRAGTORS SHALL CARRY INSURANCE THAT SATISFIES THE OWNERS AND TENANTS REQIII54=MBNT5. NAMING OWNER AND TENANT A5 ADDITIONAL INSURED. 21. ALL MATERIALS (INGLUDIN6 MECHANICAL, PLUMBING AND ELECTRICAL ITEMS) USED WITHIN CONGEALED 5PAGE5 SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING CODE 201 SECTION 717. 22. PRIOR TO GUTTING, CORE DRILLING, FASTENING, ETG. ALL CONTRACTORS SHALL THOROUGHLY EXAMINE THE EXISTING WALL / FLOOR CONSTRUCTION FOR EXISTING CONDUITS, GABLES, PIPIN6 AND STRUGTURAL ITEMS, TO ANY EXTENT NEGE55ARY TO AVOID THE ACCIDENTAL GUTTING OF MEGHANICAL AND 5TRUG7URAL ITEMS WITHIN EXI5TIN6 CONSTRUCTION, THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR THE GUTTING OF ANY EXISTIN6 CONDUIT, GABLE, PIPE, STRUCTURAL MEMBERS, ETG.. 23. USE PRODUCTS THAT ARE "LOW ODOR" TYPE. COMPLY WITH ALL FEDERAL REQIUIREMENT5 FOR VOLATILE ORGANIC GOMPOUND5 (V.OL) CONTENT, INGLL INC OZONE TRANSPORT COMMISSION (OTG) REGULATION NO. 41 AND U.S. ENVIRONMENTAL PROTEGTION A6ENGY (EPA), STATIONARY 50URGE5 GOMPLIANGE DIVISION, METHOD 24. 24. THESE DRAWINGS D0 NOT CONTAIN THE NECESSARY COMPONENTS FOR GON5TRUGTION SAFETY. THE CONTRACTOR 15 SOLELY RESPONSIBLE FOR MAINTAINING A SAFE WORKIN 6, ENVIRONMENT FOR ALL WORKERS, BUILDIN6 OGCVPANTS, NEIGHBORS, V151TOR5 TO THE BUILDING AND PASSING PEDESTRIANS AND MOTORIST5. 05HA REQUIREMENTS SHALL BE CONSIDERED A MINIMUM REQUIREMENT AND THE CONTRACTOR SHALL TAKE ALL PREGAUTION5 NEG-ESSARY FOR THE SAFETY OF PERSONS AND PROPERTY. 25. ALL ENGINEERS PROVIDING PROFESSIONAL ENGINEERS SERVICES DIRECTLY OR INDIREGTLY FOR THE OWNER SHALL PROVIDE INSURANCE GERTIFIGATE5 TO THE TENANT THAT MEETS THE TENANTS NEEDS. 26. IT 15 THE CONTRACTORS RE5PONSIBILITY TO REVIEW THE COMPLETE SET OF CONSTRICTION DOCUMENTS (INCL UDIN6, BUT NOT LIMITED TO, SOILS REPORT, SITE, 5TRIGTURAL, MEGHANIGAL, PL.UM13IN6, ELECTRIGAL, FIR'_ SUPPRESSION, ETG., DRAWUNG5 AND/OR SPEGIRICATONLS) A5 APPLICABLE. SHOULD CONFLICT OGGUR IN OR BETWEEN SPECIFICATIONS AND/OR DRAWIN65, THE CONTRACTOR 15 DEEMED TO HAVE ESTIMATED ON THE MORE EXPEN51VE WAY OF DOING WORK UNLESS THE CONTRACTOR SHALL HAVE ASKED FOR AND OBTAINED WRITTEN DECISION BEFORE SUBMISSION OF BID A5 TO WHICH METHOD OF MATERIALS WILL BE REQUIRED. IT 15 THE CONTRACTORS SOLE RESPONSIBILITY TO PROVIDE THE COMPLETE SET OF CONSTRUCTION DOGIR-1ENT5 TO AND 5UPERV15E THE COORDINATION OF ALL SUBCONTRACTORS AND VENDORS. 27. 6YP5UM WALL BOARD PRODUGT5 MANUFACTURED IN CHINA ARE NOT ALLOWED ON THIS PROJECT. THE 6ENERAL GONTRAGTOR SHALL 60 TO ANY EXTENT NECESSARY TO ENSURE THAT THESE MATERIALS ARE NOT MANUFACTURED IN CHINA. 28. WOOD BLOCKIN6 USED WITH A STUD CAVITY SHALL BE FIRE RETARDANT. (THE PROPER NON-GORR05NE FASTENERS SHALL BE UTILIZED). 56FEGUAR25 DURING 005TRUGTION: (5EE CHAPTER 33, BUILDING CODE OF NYS, 2010 EDITION) THE GENERAL CONTRACTOR AND ALL 50 -CONTRACTORS SHALL PROVIDE ALL WORK IN ACCORDANCE WITH CHAPTER 33 "5AFE6UARD5 DURING CON5112U6TION," CONTAINED WITHIN THE INTERNATIONAL. BUILDIN6 CODE AND CHAPTER 14 "GON5TRUGTION 5AFE5UARDS" CONTAINED WITHIN THE EXI5TIN6 FIRE CODE OF NY5 2010. I. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL METH005 AND MEANS OF CONSTRUCTION AND SHALL BE RE5PON5IBLE TO THE OWNER FOR PROVIDING A SAFE WORK ENVIRONMENT DURIN6 THE REMOVAL AND CONSTRUCTION PERIOD. THIS BUILDING MAY BE OCCUPIED. EVERY EFFORT SHALL BE MADE BY THE GONTRAGTOR TO PROTECT THE OGCUPANT5, CUSTOMERS AND NEIGHBORS FROM THE HAZARDS OF CONSTRICTION. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, THE ERECTION OF BARRIERS AND 516NA6E, PROPER STORAGE OF MATERIALS IN DE516MTED AREAS, ETG. IN ADDITION, EXI5TIN6 EXITS AND SAFE PUBLIC, AC -GESS MUST BE MAINTAINED AT ALL TIMES. 2. IT 15 THE GONTRAGTORS RESPONSIBILITY TO INSURE THAT EMPLOYEES ARE TRAINED TO PROPERLY MINIMIZE 5APETY HAZARDS AND TO SAFELY OPERATE THE EQUIPMENT, WHICH THEY USE TO PERFORM THE REQUIRED WORK TASKS, CONTRACTOR SHALL PROVIDE OR REQUIRE EMPLOYEES TO HAVE PER50NAL PROTEGTIVE EGUIPMBNT (PPE) NECESSARY TO PERFORM THE WORK TASKS. 3. THE GONTRAGTOR 15 RE5PON51BLE TO PREVENT ALL SERVICE INTERRUPTIONS DUE TO CONTRACTORS WORK OPERATIONS RE6ARDLE55 OF WHETTER OR NOT THE POTENTIAL INTERRUPTION WA5 IDENTIFIED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR 15 Al -50 RESPONSIBLE FOR ALL DAMAGE5 TO OWNERS A55M CAUSED BY THE CONTRACTOR WORK OPERATIONS. GLEANING: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINIHS A GLEAN WORK SITE AT ALL TIME -5. AT THE END OF EACH DAY CONTRACTORS SHALL STORE ALL TOOLS AND MATERIALS IN THE IDE516NATED AREAS AND ALL SPACES CLEANED. 2. ALL DEBRIS AND WASTE E5ULTIN6 FROM THE WORK OF THI5 CONTRAGT AND MATERIAL NOT RETAINED BY THE OWNER 514ALL BE PROMPTLY REMOVED FROM THE BUILDING 51TE ON A DAILY BASIS, AND DISPOSED OF LE6ALLY. 3. SPACE SHALL BE LEFT AT THE END OF EACH DAY IN A 'GLEAN' CONDITION: FLOORS GLEANED BY UTILIZI% WET MOP, TACK CLOTH OR HEPA VAGUUM; WINDOWS, DOORS AND FRAMES OF DUST AND DIRT; EXCESS MATERIALS REMOVED, ETG. PORTABLE FIRE EXTINGUI5HER5: (5EE CHAPTER 33, BUILDING CODE OF NYS, 2010 EDITION) 1. PORTABLE FIRE EXTIN6U15FERS SHALL BE PROVIDED AND INSTALLED IN AGGORDAMCE WITH THE GURRENT N.Y5. FIRE CODE, NFPA STANDARDS AND AS DIRECTED BY THE LOCAL FIRE INSPECTION OFFICIAL. THE CONTRACTOR SHALL PROVIDE TEMPORARY FIRE EXTIN0,1151 ON 51TE DURI% ALL PHASES OF CONSTRUCTION IN ACCORDANCE WITH THE BUILDING CODE OF NEN YORK STATE. Tl'PIGAL_ FIN15H NOTES: (ALL FINISHES ARE TO BE COORDINATED WITH AND APPROVED BY OWNER AND TENANT) I. FOLLOW REQUIREMENT5 AS SET FORTH IN THE BUILDING CODE OF NM YOM STATE CHAPTER 8 FOR ALL INTERIOR FINISHES COORDINATE WITH THE OWNER AND/OR TENANT. 2. PROVIDE AN APPROPRIATE ADA COMPLIANT TRAN51TION STRIP AT THE INTERSECTION OF UNLIKE FLOOR 5URFAGE5 TO ENABLE A SMOOTH TRANSITION. SEE A/A-3 FOR ADDITIONAL INFORMATION. 3. CEILIN6 FINISHES WITHIN TENANT SPACES SHALL BE CLASS 'A' MIN. 4. WALL FINISHES WITHIN TENANT 5PAGC-5 SHALL BE CLA85 'A' MIN. 5. FLOOR FINISHIES WITHIN TENANT SPACES SHALL BE GLASS II. 6. VGT FLOOPINY SHALL BE GLEANED AND WAXED W/A 'NON -SLIP' FLOOR FINISH. THE OWNER SHALL BE INSTRUCTED BY THE CONTRACTOR HOW TO MAINTAIN THI5 FINISH. 7. PAINT PROVIDED SHALL BE OTG COMPLIANT AND 'LOW ODOR' - 'LOW OR NO VOC" TYPE. B. FLOORING ADHESIVES SHALL BE OTC, COMPLIANT 'LOW ODOR" - 'LOW OR No LOG' TYPE AS REGOMMENIDED BY THE FLOORING MANUFACTURERS. q. LEVEL CONCRETE FLOORS, PATCH AND REPAIR EX15TIW FLOOR CRACKS AND HOLES, AND GLEAN FLOORS A5 REQUIRED TO RECEIVE NEW FIN15HE5. LEVELING MATERIALS SHALL BE AN APPROVED TYPE L15TED BY THE FLOOR FIN15H MANUFACTURER. COORDINATE WITH THE FLOORIN6 5UPPLIER. 10. A MOISTURE TEST SHALL BE GOMPLETED ON ALL NEW OR EXI5TIN6 GONGRETE FLOOR SLABS TO ENSURE MOISTURE CONTENT MEETS ALL FLOORN6 MATERIAL AND ADFE51VE REQUIREMENTS PRIOR TO INSTALLATION. INSTALLATION SHALL NOT BE DONE UNTIL THE M015TLIRE IN THE CONCRETE 15 AT THE MANUFAGIURERS PUBLISHED LEVELS. 11. ALL SCHEDULED GWB SHALL RECEIVE ONE FULL GOAT OF PRIMER AND TWO GOATS OF A LATEX PAINT SELECTED BY THE TENANT. 12. PROVIDE A "FIN5IGIDE' ADDITIVE TO ALL GEILIN6 AND WALL PAINTS USED WITHIN TOILET ROOMS. 13. ALL PRIMERS SHALL BE A 'STAIN BLOCK' TYPE. 14. ALL FLOOR@DG FINISHES MUST HAVE THE MINIMUM COffFIG1ENT OF FRICTION FOR HANDIGAP FAGILITIE5. a ,. ' ,...r LANMCFV I' I' LA<E 6EOR6E RETA I L II 'I 6EOW7E, NEN YOW 12645 A, 5GOPE OF WORK: THE SCOPE OF WORK INCLUDES THE MODIFICATIONS TO AN EXISTIN6, VACANT TENANT SPACE. THERE 15 NO GHANI5E IN BUILDING AREA, USE OR OCORANGY. THE ADJACENT TENANT 15 TO MOVE INTO THE NEW VANILLA BOX AND THAT WORK SHALL BE PROVIDED UNDER A SEPARATE PERMIT. THE DRAWINGS: I. DO NOT SCALE DRAWINGS. DRAWING5 MAY NOT BE TO SCALE. DIMENSIONS TAKE PREGEDBNGE OVER SCALE. THE CONTRACTOR 15 RESPONSIBLE FOR THE REVIEW OF ALL DETAILING AND DIMEN510NINL6. 2. THE FULL SET OF DRAWIN65 544ALL BE SUBMITTED, BY THE GONTRAGTOR, TO THE CODE ENFORCEMENT OFFICE OF THE AUTHORITY HAVING JURISDICTION AND A BUILDIN6 PERMIT ATTAINED PRIOR TO GON5TPUGTION. A GERTIFIGATE OF OGGUPANGY/GOMPLETION SHALL BE OBTAINED (FROM THE CODE ENFORCEMENT OFFICE OF THE AUTHORITY HAVING JURISDICTION) BY THE CONTRACTOR AND PROVIDED TO THE OWNER AFTER THE WORK 15 COMPLETED. GODE5, PERMITS AND INSPEGTION5: I. THE CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOGO , GM%MW, W CODES, RULES, RE6ULATION5 AND ORDINANCES INCLUDING, BUT NOT LIMITED TO, THE INTERNATIONAL BUILDING CODE "FAMILY' 200q (TBG), THE AMERICANS WITH D15ABILITIE5 ACT (ADA), At -MEGAN NATIONAL STANDARDS INSTITUTE (ANSI), IGG/AN51 A1111-2003, NATIONAL FIRE PROTECTION ASSOCIATION (LAPPA), AND THE OCCUPATIONAL 5AFETY AND HEALTH ADMIN15TRATION (OSHA), WHETHER OR NOT INFORMATION AND/OR WORK 15 SPECIFICALLY SHOWN ON THE DRAWIN65. 2. ALL NEW ELECTRICAL WORK SHALL CONFORM TO THE FIRE AND BUILDING CODES OF NEW YORK STATE, THE LATEST ADOPTED NATIONAL ELECTRIC, CODE, THE NATIONAL ELECTRIC 51 CODE A5 WELL A5 ANSI, NEMA, INSTITUTE OF ELEGTRIGAL AND ELECTRONICS ENGINEERS INC. (IEEE), HFPA, UNDERWRITERS LABORATORIES INC., AND ALL LOCAL, GtiY, NY F1 FGTRIGAL CODES AND ORDINANCES. THE CONTRACTOR SHALL PERFORM ALL WORK IN GONFORMITY WITH THESE REQUIREMENTS WHETHER OR NOT INFORMATION AND/OR WORK 15 SPECIFICALLY SHOWN ON THE DRA 41%5. ALL ELECTRICAL WORK SHALL BE INSPECTED AND THE CONTRACTOR SHALL FURNISH THE OWNER WITH THE UL. CERTIFICATE OF APPROVAL AT THE END OF THE PROJECT. 3. THE ELEGTRIGAL CONTRACTOR SHALL FURNISH A GERTIFIGATE AT THE END OF THE PROJECT TO THE GENERAL CONTRACTOR, BUILDIN6 DEPARTMENT AND OWNER GERTIFYIN6 THAT THE FIRE ALARM SYSTEM MODIFICATIONS WERE GOMPLETED AND THAT THE SYSTEM 15 OPERATING IN COMPLIANCE WITH NEPA 72 REQUIREMENT5. 4. THE CONTRACTOR SHALL RURNI5H A GERTIFIGATE OF GOMPLETION AT THE END OF THE PROJECT TO THE BUILDING DEPARTMENT ! OWNER INDIGATINIS THAT THE EMERGENCY LIGHTING HAS BEEN INSPEGTED d TESTED WITH THE ACCOMPANIMENT OF A QTY, [YY BUILDING DEPARTMENT OFFIGIAL AND COMPLY WITH ALL REQUIRED GODES. 5. THE GENERAL CONTRACTOR SHALL SCHEDULE ALL REQUIRED INSPEGTIONS WITH THE BUILDING DEPARTMENT AND OTHERS AS REQUIRED TO RECEIVE THE NECESSARY APPROVALS. 6. GLAS51FICATION PER INTERNATIONAL BUILDING GORE 2009 EDITION: NOTICE FOAM INSULATION MUST BE OCCUPANCY GLA551FIGATION: USE MERCANTILE GROUP M NNGHAM6ED). COVERED BYA 15 MINUTE GON5TRUGTION TYPE: TYPE VB (GOMB05'iIBLE). THERMAL BARRIER M 00 V1 IZA W U BUILDING HEIGHT: EXI5TI% 29-4 , NIC) GHANGE - ACTUAL NUMBER OF STORIES: ONE-STORY. ACTUAL BUILDING AREA: t 14,21q S.F. (EXISTING - UNGHAN6ED). ACTUAL TENANT AREA: 1,902 S.F. (EXI5TIN6 - UNGHAN6ED). EXIT ACCESS TRAVEL DISTANCE: 250 FEET MAXIMUM (GROUP "M"). In COMMON PATH OF TRAVEL: 75 FEET MAXIMUM (6ROUP 'M"), 100 FEET MAXIMUM (GROI/PS 'B' AtNLNOTICE NS -111) KRAFT PAPER INSULATION MANUAL FIRE ALARM SYSTEM: THE EXI5TINI6 SYSTEM SHALL BE MODIFIED TO MEET NFPI BE COVERED BY REQUIREMENTS. 51EE ELEGTRIGAL ENGINEER DRAWINIIMBUSTIBLE BARRIEF. ADDITIONAL INFORMATION. vv AUTOMATIC SHUTDOWN OF WAG EQUIPMENT: EXI5TI% - UNGHANIII VENTILATION: EXISTING- UNGHANI ED. .'j OGGUPAN C,Y: UNCHANGED. NOTE: L16HTIN6: WATTAGE 15 NOT BEING INCREASED WITH THESE ALTERATIONS. fr (� >"' � 11Z1 ul TOILET ROOMS: � REQUIRED, I PROVIDED LTOWN [�-.' 1 ., i� Il � i� . , DRINKIN6 FOUNTAINS: I REQUIRED, I PROVIDED 1)JANITORS SINK: I REQUIRED, I PROVIDED J 2015GHANGE ORDERS: UE! L I. GHANiE ORDERS WILL NOT 13E PAID UNLESS THE G05T IS PRE -APPROVED IN NRITIN6 BY THE &"D`' -ry OWNER PRIOR TO THE WORK BEING STARTED AND/OR MATERIALS BEING ORt�t32Ep, Z GONTRAGTOR LI042NG,aG!UIREMENT5: _ T I. ALL GONTRACTOR5 SHALL POSSESS ANY AND ALL Ll,EFNSE5 REQUIRED BY THE OUSSW RY, W TO PERFORM THE WOPK OF THEIR TRADE. NOTICE � RETAIL EXIT ANALY515: LEVER HANDLES REQUIRED ON ALL PASSAGE DOORS RETAIL AREA: I,IIq S.F. DIVIDED BY 30 5.FJPEREON = 38 PEOPLE WHETHER INTERIOR OR W 13AGK OF HOUSE: 783 S.F. DIVIDED BY 100 SF)PERSON = 8 PEOPLE EXTERIOR DOORS 46 PEOPLE X.15 INCHES/PERSON = 6A INGHES (REQUIRED). DRAWING 5GHEDULE: ARLHITEGTIRAL DRAWINGS N-1 COVER 5HEE FILE COPY p R-1 FLOOR 6 GELLING REMOVAL PLANS A-1 FLOOR b CEILINS PROPOSED PLANES A-2 DETAILS E 51 ® R I I I I I I I I I I----- --'---=--------'------ ' -i-------'----------' --------' REVISIONS I °n NSC.OPF] i AZiMA ; Nnf"iK PROJECT No. 14180 4 I DATE: _1___/14 I I I I I 1 Ep5TN6 jE+IAIIT 1 1NDr '�xePl FJ SCALE: 1/8" = 1'-0" 1 fEE MM o-_- _ y_ _ -_ - SHEET TITLE: �GOVER 5HEET I I I I 1 I ! I 1 TOW4 OF QUEENS RY BUILDING DEPARTMENT I SHEET NO. Based on our limited examination, compliance A -I OWN OF QUE SB with our comments shalt ,lot be construed as BUILDING & D E indicating the plans and specifications are in full compliance with the Building Codes of New York State. Reviewed By: .�. KEY PLAN Date: H w N -I NM a W 1418 6 i 1 PROP05ED FLOOR PLAN r2--� PROP05ED REFLEGTEi7 GEILIN6 PLAN -1 I SCALE: 1/8" = 1'-0' �A : I/5' KEYED PROPOSED PLAIN NOTES: o--> GENERAL GON5TRUGTION NOTES: I. NEW STOREFRONT SYSTEM 451T BY KAWNEE'R, CLEAR ANODIZED FRAME TO BE GONFIRMED BY OWNER. SEE DR SCHEDULE I. REMOVE AND PROPERLY DISPOSE OF ALL OF THE SUSPENDED 6RID, ACOUSTICAL GEILIN6 TILE THROUGHOUT THE FOR ADDITIONAL INFORMATION STORE. REMOVE AND REPLACE EXISTING FLUSH FLOOR GLEAN OUT5 AS NEEDED 50 THAT THEY ARE "FLUSH WITH THE 2. NEW ADA GOMPLIANT TOILET ROOM, SEE A2.0 FOR ADDITIONAL DETAIL. PLUMBINIG FIXTURES 5HOWN FOR REFERENCE FINISH V.G.T. ELOORIN6". 2. FIRE EXTINGUISHERS "LIKE NEW CONDITION" CAN BE REUSED BUT MUST BE RE -CERTIFIED. ONLY. SEE PLUMBING DocuMENT5 (BY oTHER5) FOR 5GOPE, SPEGIFIGATION5 AND DETAILS. 3. THE GENERAL GONTRAGTOR'S LEGTiRIGAL ENGINEER SHALL DESIGN AN EMERGENCY LIGHTING SYSTEM FOR THE THE cEN E H NONE BUILDING IN WITH THE BUILDING GODS NEW YORK STATE (2010) SECTION IOOG. IN ADDITION, THE 3. NEA FLOOR MOUNTED MOP SINK. SEE PLUMBING DOGUMENT5 (BY OTHERS) FOR SCOPE, 5PECIFIGATIONS AND DETAILS. ALLCONDE-MANGE 6 EN6INE�R SHALL DESIGN THE ILLUMINATED EXIT SIGNAGE SYSTEM FOR THE BUILDING IN CONFORMANCE: WITH THE TAPE BUILDING CODE OF NEW YORK STATE SECTION 1011. THE INFORMATION SHOWN THE DRAWINGS "GENERAL IN 4. NEW ADA GOMPLIANT HIGH/LOW DRINKING FOUNTAIN. PROVIDE WOOD BLOGKIN6 A5 REQUIRED TO ACCOMMODATE NEW A T NAGE" SIGNAGE AND LIGHTING MAY NEED TO BE ADDED, DELETED AND/OR RELOCATED AS NEEDED TO PROPERLY NEE E PLUMBING DOCUMENTS (BY OTHERS) FOR SCOPE, SPECIFICATION AND DETAILS. EXIT AND LIGHT THE EXIT PATHWAYS. EXIT 516NA6E AND LI6HTIN6 WILL NEED TO BE COORDINATED WITH AISLES YES BETWEEN MERGHANP15E, HE16HT OF DISPLAYS, HEIGHT OF STOCK ROOM 5TORA6E, ETG. 5. NOT USED 1 4. ALL EXIT DOOR5 SHALL BE CHECKED AND REPAIRED AS NEEDED 50 THAT THEY ARE OPERA rINC, PROPERLY. 5EGTION 5. REMOVE AND DISPOSE OF ALL TRASH AND DEBRIS THROUGHOUT THE ENTIRE STORE. 6. ALI6 PAGE OF NEW PARTITION AND PAGE OF STOREFRONT WITH FACE OF EXI5TIN6 COLUMN YES 1. RI LABEL EXISTING ELEGTRIG PANEL ID 8. NO STEP AT REAR EXTERIOR DOOR. SEE SITE DRAWINGS (SEPARATE 5GOPE BY OTHERS) FOR ADDT'L INFO. V R I]/A-! PROVIDE ARROW WHEN THE NO PROVIDE STIGKER AT THE FIRE DEPARTMENT GONNEGTION AND AT ENTRANGE5 INTO THE BUILDING OP EXTIN6UI5HER I5 NOT 9. PROVIDE A NEW WALL MOUNTED 4A:bOBG FIRE EXTINC J151 ER. 9 6/A-1 CLEARLY VISIBLE LL 10. LINE OF EXISTING ROOF KEYED PROP05ED GE I L I NG NOTES: o-� "FIRE EXTINGUISHER' 516NA6E - (rW0 OPTION SHOWN) 1. NEIN 2X4 TEGULAR TILE ACT GEILIN6 BY ARMSTRONG OR EQUAL AT 0-0" AFF. FULL TILE CENTERED ON SPACE. NEW AND/OR RELOCATED 2. NEW 2X4 TE60LAR TILE, "SECOND LOOK," AGT CEILING BY ARMSTRONG OR EQUAL AT W -O" AFF TYPE "ABG" FIRE EXTINGUISHER (SEE FLOOR 3. RELOCATED EMER6ENGY EXIT 516NPLAN m z_ FOR SIZE). 4 6ND BULKHEAD AT 9'-0" AFF PROVIDE DOUBLE b" X I6 6AU5E HEADER WITH (2) ,AGK 5ND5 AT EACH END - FINISHED FLOOR 5. NEW 2X4 FLUORESCENT L16HT FIXTURES SHOWN FOR REFERENCE ONLY. SEE ELECTRIGAI DOGUMIENT5 (BY OTHERS) FOR SCOPE, SPECIFICATIONS AND DETAILS. 6. RELOCATED EXIT 516N 1. NEW GEILIN6 OR WALL MOUNTED GOMBINATION EXIT AND EMERGENCY LIGHTING FIXTURE WITH 1-1/2 HOUR BATTERY BAGK-UP, ARROI, I INDIGATE5 I2 DETA I L(FIRE EXTINiSun R MOUNTING HE16HT) EXIT DIRECTION, SHOWN FOR REFERENCE, SEE ELECTRICAL DRAWINlG5 FOR SCOPE 5PECIFIGATION5 AND DETAILS H. NEW WALL MOUNTED EMER6ENGY LIGHT FIXTURE WITH 1-1/2 HOUR BATTERY B/oGK-UP, 5HOWN FOR REFERENCE, SEE ELECTRICAL DRAWIN65 A -I SCALE: FOR SCOPE SPECIFICATIONS AND DETAILS 9. NEW EMERGENCY EXTERIOR LIGHT FIXTURE WITH 1-1/2 HOUR BATTERY BAGK-UP, SHOWN FOR REFERENCE, SEE ELECTRICAL DRAWIN65 FOR SCOPE SPECIFICATIONS AND DETAILS 5 (% I � C G� L� �iI I I PROVIDE ROOM 516NA6E IN ACCORDANCE WITH THE BUILDING CODE OF NEW YORK y I i� L J n L U L STATE AND ANSI 11-7.1 SYMBOL WORDAGE PIGT06RAM DETAIL MOUNTING DETAIL BRAILLE REMARKS EX EXIT NONE 3/A-1 6/A-1 YES TAPE EA EXIT A66E55 NONE 6/A-1 6/A-1 YES ( T ) / REST ROOM 5EGTION 6/A-1 YES ID (SEE DETAIL) V R I]/A-! 10/A -I NO PROVIDE STIGKER AT THE FIRE DEPARTMENT GONNEGTION AND AT ENTRANGE5 INTO THE BUILDING OP THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING 15 OGGUPIED NONE 5/A-1 6/A-1 NO ��� PROVIDE AN APPROPRIATE 5YMBOL FOR THE LOCATION THAT 51GN 15 GOING TO BE INSTALLED 8' OR AS L % s AM � D m RE T ROOM N V PROVIDE THE 1,32" RAISED BRAILLE APPROPRIATE (CORRESPOND TO TEXT) LANGUAGE ON EACH SIGN (MIENS, WOMENS, ETC) REQU I REMENTS INA NTT THE COLORS of ALL MATERIALS SHALL NTSE COLORS OF ALL MATERIALS SHALL NT5 BE COORDINATED WITH THE ONAlER. IF - 6" MINIMUM PIGTO6,RAM FIELD - - (TACTILE GHARAGTER5 AND BRAILLE SHALL NOT BE LOCATED IN THIS AREA) TACT W CHARAC �X LL Q�U SEE 516NA6E SCHEDULE FOR J FURTHER INFORMATION THIS DOOR TO T' n UNLOCKED A 111, , WHEN BUILDING IS OCCUPIED EGRESS 51DE LOGK 516NA6E REQUIREMENTS -I THE GOLORS OF ALL MATERIALS SHALL NTS BE GOORDINATED WITH THE OWNER COLOR -PICTOGRAM (RAISE 5YMBOU: SURFAC COLOR N O — I/8" MP PLASTIC z a, DOUBLE- 51DED VIN � a w A TAPE - 1/32' RA15EP COP SURFACE COLOR GRADE 2 BRAILLE SURFACE COLOR] 9"J 5EGTION �i Fei TYPICAL A.D.A. COMPLIANT 516NA6E AT LOGK5ET 51DE DOOR (PREFERRED LOGATIC 5EGOND OPTION 15 NEAREST ADJAGENf WALL) SIGNAGE MAY BE LOCATED ON DOORS WHERE THEY 5WIN6 INTO A ROOM. SEE FLOOR PLAN FOR THESE LOCATIONS EX EXIT ry 1/32" RAISED BRAILLE (CORRESPOND TO TEXT) EXIT 516NA6E REQUIREMENTS THE COLORS OF ALL MATERIALS SHALL BE COORDINATED WITH THE OWNER. EA 6" MINIMUM EXIT-_' ACCESS 747`5 TACTILE G+ARAGTER PER SECTION 1033 OF AN51 All -7.1 z f Il32" RAISED BRAILLE (CORRESPOND TO TEXT) PER SECTION 103.4 OF AN51 AIIT.I "EXIT AGGE55" 516NA6E REQU I REMENT5 THE GOLOR5 OF ALL MATERIALS SHALL BE GOORDINATED WITH THE 004E R. NTS - FIN. FLR. ELEVATION TYP I GAEL TAGT I LE 516NA6E MOUNTING DETAIL REQUIRED FOR ALL PERMANENT ROOMS IN ACCORDANCE WITH THE BUILDING CODE OF NEW YORK STATE AND AN51 Al 1-1.1 TYPICAL A.D.A. COMPLIANT 516NA6E AT LOGKSET SIDE OF DOOR (PREFERRED LOCATION) q.. ROUND OFF GORNERS WITH 1/2" RADIUS LATCH 51DE TYPICAL ADA COMPLIANT SIGNAGE AT LOCK ET SIDE OF DOOR (PREFERRED LOCATION) A.D.A. H16HEST CHARACTER. 516NA6E LOWEST GHARAG TYP I GAEL HAND I GAPPED _ 516NA6E MOUNTING DETAIL NT5- REQUIRED FOR ALL PERMANENT ROOMS IN SCALE: NONE AGGORDANGE WITH THE BUILDING CODE OF NEW YORK STATE AND AN51 A111.1 OPTION 2: ATTACH WATERPROOF DECAL TO 1/4" PLEXIGLASS AND FASTEN TO THE BUILDIN6 STRUCTURE WITH (4) STAINLESS STEEL 51GREW5 ON THE LATCH 51DE OF THE DOOR, OPTION I: WATERPROOF DECAL MAY BE PLACED ON THE DOOR OR SIDE L16HT TYP I GAIL HArND I GAPPED BU I LD I NG GONSTRUGT I ON/ 51 GNA 667E MOUNTING DETAIL to TRU55 51 GN LOGAT ION REGIUIRED FOR ALL PERMANENT ROOMS IN SCALE: N.T.5. �1-I AT 6LL EXTERIOR DOORS LEADING SCALE: 1/2' = 1'-0' AGGORDANGE WITH THE BUILDING CODE OF NEW INTO THE BUILDING AND ROOF HATGF♦E5 YORK STATE AND AN51 AII1.1 mV„1e4 REVISIONS 06/02/2015 COORDINATION 6 -- DIAMETER WATERPROOF DEGAL REFLECTIVE REly ROMAN ALPHANJMERIG PANTONE ( M5) "IBDE5!5NATION OF CONSTRUCTION TYPE BA5ED ON SECTION 602 OF PROJECT No. 14180 THE BUILDING CODE OF NEW YORK STALE DATE: J�JI4 ry REFLECTIVE WHITE SCALE: 1/8" = I'-0" v4" SHEET TITLE: I- DES16HATION FOR STRUCTURAL SHO6- V5TIED CONSTRUCTION AT ARE OF TRUSS PL PLA N5 TRU55 IDENTIFIGAtTION SIGN SHEET NO. GOMPLIANGE WITH IQ 77 II NYGRR PART 1264 Ti GONTAGT TRU%ID.C.OM FOR FURTHER INFORMATION NI m N F W LI 14180 a tt1 z Q N O � z a, � Q d r -i � a w A � REVISIONS 06/02/2015 COORDINATION 6 -- DIAMETER WATERPROOF DEGAL REFLECTIVE REly ROMAN ALPHANJMERIG PANTONE ( M5) "IBDE5!5NATION OF CONSTRUCTION TYPE BA5ED ON SECTION 602 OF PROJECT No. 14180 THE BUILDING CODE OF NEW YORK STALE DATE: J�JI4 ry REFLECTIVE WHITE SCALE: 1/8" = I'-0" v4" SHEET TITLE: I- DES16HATION FOR STRUCTURAL SHO6- V5TIED CONSTRUCTION AT ARE OF TRUSS PL PLA N5 TRU55 IDENTIFIGAtTION SIGN SHEET NO. GOMPLIANGE WITH IQ 77 II NYGRR PART 1264 Ti GONTAGT TRU%ID.C.OM FOR FURTHER INFORMATION NI m N F W LI 14180 a DOOR 5GHEOULE STOREFRONT (5F) TOILET ROOM DOOR FRAME N m� REMARKS< GMBULKHEAD > 51 ZElu W X H THK. i a -- E:l (2) b' X 16 GAUGE MEMBERS O ' I FIRST FLOOR TOILET ROOM NOTES: 201 PAIR 6-0' X T-0' 1 In' SF AL - Sf' AL 3/A-2 - TYPE OI NONE 3Q UJ WITH (2) b" X 16 GAUGE JACK STUDS AT EACH END 4-Vb' ® m i I. COORDINATE THE TYPE, LOCATION E MOUNTING HE16HT5 OF ALL TOILET ROOM ACCESSORIES WITH THE OWNER NOTE: ALL TOILET ROOM AGGESSORIES ARE BY BOBRIGK EQUAL. COORDINATE ACCESSORIES WITH OWNER AND 202 3'-0' X T-0' 1 In' METAL HM 18 f I4M - 16 TYPE 02 NONE EXISTING OPENING - E ll, :n Rr Q • 3Q j,J�/Lj/ 1 It" J� �"� 1�T EAD BULKHEAD - � : r = (' O' T.P. 18" G.B. " '- - a 42" G B. V G.T.W c' I i 'P --. GL i PROVIDE SOLID BLOGCIN6 FOR THE MOUNTING OF ALL AGGE55ORIE5 AND TOILET PARTITIONS. 2• PROVIDE EXHAUST FANS IN ACCORDANCE WITH THE BUILDING CODE OF NEW YORK STATE. 3. SEE TYPICAL BARRIER FREE ACCESSIBILITY MOUNTING DETAILS, THIS 5I�T, FOR MOLNTINFi HEIGHTS OF TE TENANT. SD. SOAP DISPENSER M. MIRROR H.G. BARRIER FREE WATER GL05ET T.P. TOILET PAPER D15PER5ER 6B. GRAB BAR V.G.T. VINYL TILE O z � cf > O � 203 3'-0" XT-O" 1 In' F SGW - f HM - 16 TYPE 03 NONE 204 3'-0' X T'-0' 11/2, F SON - 7 HM - 16 TYPE 04 IHR PASSAGE SET HA�RDINAsRE 5GHEDULE : DOOR SCA0Z E ABBREVIATIONS: PAINT n V (GOA H. 0 HANDICAPPED FIXTURES AND ACCESSORIES. SMP.TD. SURFACE MOUNTED PAPER TOWEL DISPENSER BARRIER FREE LAVATORY a PROVIDE HARDWARE FOR EACH DOOR FROM THE FOLLOWING LIST OF ALUM. ALUMINUM PT L. HARDWARE SETS. ALL HARDWARE SHALL BE HANDICAP ACCE551BLIE 4. PRIOR TO GUTTING, CORE DRILLIN6, ETC,. ALL T.S. TRANSITION STRIP Q 3 M WITH A FINISH SECTED BY THE OWNER. COORDINATE "COMMERGIAL DUTY" WLE EX EXISTING TO REMAIN 5GW 50LID CORE WOOD I2'-0" PROVIDE (2) JACK STUDS AT � SD. CONTRACTORS SHALL THOROUGHLY EXAMINE THE FLOOR AND/OR WALL GONSTRUGTION FOR CONDUITS, GABLES, 3 v� Z WITH THE OWNER. ALL HARDWARE W (VIF) EACH END OF NEW HEADER T.S. L_ PIPING AND STRUCTURAL ITEMS (BAR JOISTS, � NOTE: RE-KEY FRONT EXISTING DOOR H HEIGHT THK THICKNESS " '-0 3/4" b'-O' 2'-II 13/16' - -- GL , P STRIiGTURAL STff1, AN6LE5, ETG) TO ANY EXTENT A < 00 TO MEET THE OWNER'S AND FIRE MARSHALL'S REQUIREMENTS. HM HOLLOW METAL W WIDTH M. = NEGE%ARY TO AVOID THE ACCIDENTAL GITI-E OF 00 g TYPE OI i I n MECHANICAL ITEMS WITHIN GONSTRUGTION. 1'}E I EA TOP AND BOTTOM OFFSET PIVOT (KAWNEER) MATL MATERIAL WD WOOD I i ------ - 5.M.P.TD. --- CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR THE GUTTING OF ANY MECHANICAL, ELECTRICAL, H Q I EA INTERMEDIATE PIVOT (KAWNEER) (ADAMS RITE) PR PAIR WHM WELDED HOLLOW METAL ' b' b' PLUI•IHIN6 OR STRUCTURAL ITEMS. I EA DEADLATCH I EA MORTISE GYLINDER (SARGENT) _ _ (INSIDE CLEAR) C/] I EA DEADLATGH PADDLE (ADAMS RITE) - - — - - - - -_-- - W I EA FUSH BAR GP-11 #14 CLEAR ANODIZED 1 EA PULL 60-15 #14 CLEAR ANODIZED (KAWNEER) (KAWNEEW i AL16K CENTER OF DOOR WITH I h�+�%I! F% I EA CLOSER (TOP JAMB MOUNT) /, i /, i Fes{ N(OOD EXISTING EXTERIOR PAIR OF I EA THERMALLY BROKEN THRESHOLD FOR OFFSET PIVOT X 72" ALUM (KAWNEER) SPECIES 6 STOREFRONT DOORS I SET NEATHER STRIPPING STANDARD WITH BLADE STOP (KAWNEER) / / AS s STOREFRONT TOILET ROOM PLAIN GLAZING TO BE 1/4" TEMPERED GLA% BY SELEGIED BY SELECTED THE OWNER I W W O TYPE 02 ' / SCALE: I/4' = I'-0' �-�-/— SCALE: 1/4'= I'-0' � 3 EA HINGE (MGKINNEY) /, / /, / GALVANIZED INSULATED— x I EA LOGK5ET (ENTRY FUNCTION EXT.-PANIC, DEVICE INT) (SARGENT) i i / / / METAL DOOR HALL �YPE5 I EA CLOSER/STOP (SARGENT) / , I EA KICKPLATE (10" STAINLESS ON INT) (ROCKWOOD) �V/ w I EA THERMALLY BROKEN THRESHOLD (PEMKO) 'PEMIKO) /� lr) (6P) I SET HEATHER STRIPPING (PEMKO) BOTTOM CHORD OF WOOD TRUSSES I EA DOOR BOTTOM SEAL I EA LATCH PROTECTOR (ROGKWOOD) iv TYPE 03 WRAP DRAIN, HOT E 3 EA HINGE (MCKINNEY) 2° 2' 3-5/8", 20 GA. GALVANIZED GOLD WATER SUPPLIES PADDY I EA LOGK5ET (PRIVACY SET W. EMERGENGY KEY) (SARGENT) METAL 5TUD BRACES TO BUILDING STRUCTURE AT 48 O.G. MAX. (TO I EA CLOSER/STOP (SARGENT) ONE SIDE ONLY) 5/MIRROR 5' MAX. REFLECTIVE 15, MIN. FORWARD NOTE: TO AVOID METAL DOORS GONFLIGTING WITH EXTERIOR SOLID TRACK SUSPENDED AGOU5TIGAL TILE GEILIN6. SURFAGE FORWARD WRIST APPROACH APPROACH 5 45° BLADE 3-112" MAX PARALLEL TYPE 04 (MIN. IHR FIRE RATED) I (1) _ 1111111111111 FAUGET HANDLES APPROAZH OFFSET DRAIN HI I E AGE SET (MGKINNEI ) (SARGENT) DOOR AND FRAME TYPE5: PROVIDE A CONTINUOUS in I EA GL05ER/5TOP I EA KIGKPLATE (10" STAINLESS ON INT) (SARGENT) (ROCKWOOD) 3 5/8" OR b", 20 GAUGE VINYL TRIMMER AS DIRECTED BY THE S u� zJJJJ N I EA PUSH BAR GALVANIZED METAL STUDS AT CONSTRUCTION MANAGER 0 _ I EA PULL I6" O.G. MAX. SEE FLOOR PLANS FOR REQUIRED WALL THICKNESS 4 Z g PIMIN MIN. t� � DOOR AND FRAME NOTES. � � ° 5/8 TYPE X FIREGODE G.W.B. - N � � W } DO NOT PUCE BACK TO BACKX REGEPTAGLE5, SWITCHES, ETC. IN BOTH SIDES II' 6 I. ALL DOOR HARDWARE (INGLUDIN6: THRESHOLDS, GLO5ER5, LOGKSETS, ETC.) SHALL MEET AD.A. STANDARDS. THE 5AME STUD CAVITY. SPACE FAIR j II' MIN " 2. THE INSIDE OF ALL HANDLES SHALL ALWAYS BE "FREE FOR EXITING ROOMS. 3. COORDINATE THE INSTALLATION OF ALL DOORS WITH FLOOR FINISHES. AT Ib O.G. MIN. 3 In" FRIGTION-FIT, FIBERGLASS (F5c25, 5DI(450), g IT' MIN. IT MIN 4. PROVIDE RUBBER DOOR SILENCERS ON ALL DOOR FRAMES. 41. METAL STUD SOUND BATTS�J FIXTURE DEPTH 5. ALL FIRE RATED DOORS SHALL HAVE FIRE RATED HARDWARE WITH BALL BEARING TYPE HINGE5. 6. ALL HOLLOW METAL FRAMES SHALL HAVE A FACTORY BAKED-ON PRIME PAINT. 4,LAVATORY ARE TO BE INSTALLED IN ALL TYPE 02 PARTITIONS. BARRIER FREE WALL HUNG BARRIER FREE WATER 7. ALL LOCKS SHALL BE MASTER KEYED TO MEET THE OWNERS, TEN'AN'TS AND FIRE MARSHALLS REQUIREMENTS. ELEV. COOLER ELEVATION 8. PROVIDE AN APPROPRIATE WALL OR FLOOR BUMPER FOR ALL ]POURS. CONCRETE FLOOR SLAB Q. PROVIDE 5" HINGES ON ALL DOORS 31-411 LARGER. 10. CLEAR HEIGHT AT DOORS SHALL BE 7MIN. MIN. TO ANY OBST72UGTION. NPI GAIL JAsMB DETAIL MAINTAIN In" SPADE BETWEEN FLOOR SLAB AND 6W5. W II. ALL EXTERIOR DOORS AND FRAMES TO BE HOT-DIPPED GALVANIZED 12. EXTERIOR DOORS TO HAVE NON-REMOVEABLE HINGE PINS 13, ALL EXTERIOR DOORS AND FRAME5 SHALL BE INSULATED b„ 211 EXTRA STUD WITHIN d Z 4Y[ 6" OF JAMB J SYMBOL. DI 39" - 41' 0- I/4' 2 w LL 3 MAX 42' MIN. 3b' 6' NOTE 43 1/4 WALL TYPE OI -NON-RAtTED YELL �" PROVIDE ALL 4 18' 6B BLOGKIN6 ,y 1't-2WALL TYPE 3 SIM. (MOISTURE RESISTANT GNB ON ONE 51DFJ NTS f REQUIRED FOR THE VIi PRINTABLE SEALANT FRAME ANCHORS f T' `i � 36' 6B INSTALLATION BOTH SIDES ALL AND DOOR 3 PER AROUND FRAME SILENCERS (15 UNDERSIDE OF ROOF DECK TAKE CARE NOT TO PENETRATE ROOF NOTE: �9 PROVIDE ALL �( _ OF ALL GRAB 5AR5 AND 1/4' MIN. I p JAMB) BLOCKING J TOILET ROOM In ML4X. DETAIL (JAMB) WHEN ATTACHING DEFLECTION TRAGK REQUIRED 42. 66 AGGE550RIE5 b- I/ \1 HEIGHT VARIES FOR THE INSTALLATION OFA ce � 71 42' SGALE: 11/2" = 1'-0' DEFLECTION TRACK - PROVIDE A 3' ALL GRAB BARS T/SEAT 65 Q STANDARD DOOR GLEA�R,4NGE5 PROVIDE A FIRE AND SMOKE DEEP CONTINUOUS DEFLECTION TRACK AT THE TOP ALL PARTITIONS WHICH AND TOILET ROOM 4, T.PD. ACGE55ORIES T/SEAT z 'c� TPD BEVELED GHAtNC�ES TIGHT CONNECTION -SPRAY HE EXTEND TO THE EXISTING ROOF WITH U.L. APPROVED SEALING TI AND THE WOOD DECK N LE E L MATERIALS (BOTH SIDES OF WALU ANDCONSTRUCTION HE MEMBERS ALL R 5TRUGTURAL � - - TT BOTH GLo 12' MIN, It7� ALLOW 1-1120 FOR DEFLECTION. NOT GWS THE SCREW STUDTION N.T.S. TU DEFLECTION TRACK. STUDS MUST BE A SIDE FRONT SIDE AND LAT ARE PROVI ALL GONDUIT, PIPE, DUCT, BEAM, SECURED TO TRACK BUT MUST STILL CLEAR FLOOR SPACE OF:FIXTURE. - 1/4' MAX ETC. PENETkATION5 SHALL BEALLOW VERTICAL DEFLECTION. BARRIER FREE WATER GL05ET ELEVATIONS we f MADE SMOKE TIGHT U51N5 U.L. APPROVED FIRE STOPPING MATERIALS f METHODS (BOTH RECOMMENDED DEFLECTION TRACK = DIETRIGK 'SLP-TRK' LATERAL BRACING FOR INTERIOR COORDINATE TPD WITH OWNER REVISIONS 06/02/2015 BERT I GAIL GHA�NC�ES �18' MIN. SIDES OF wALU. WA1 I �, - PROVIDE 1-1/2' •G• I COORDINATION Q AWB ABOVE THE CEILING SHAPED LATERAL GALVANIZED N LEVEL 6 MAY BE FIRE TAPED ONLY (TAPE PLUS ONE GOAT) STEEL HORIZONTAL BRACING AT THEWH TOP OF ALL WALLS ERE A ONE-PIECE DEFLECTION TRACK 15 PTD PTD AL2 N.T.S. b', 20 GAUGE GALVANIZED BEING USED. PROVIDE LATERAL FRONT APPROACH. RILL 51DE FRONT APPROACH. PUSH SIDE METAL STUDS AT I6" O.G. MAX. BRACING AT 4'-0' O.G. IN ALL INTERIOR WALL WHERE THE UNBRAGED LENGTH EXCEEDS 10'-0". FA5TEN LATERAL BRAGING TO OUTLET PAPER OUTLET PAPERAND/OR SYMBOLS LEGEND: NEW SINGLE POLE 5WITCH. 4' STUDS U51% METAL CLIP ANGLES. CONTROL (Ty -REMOVE. PROJECT No. 14180 DO NOT PLACE BACK TO BACK REWORK EXI5TIN6 5USPENDED o- SURFACE MOUNTED FIRE EXTINGUI51 - SEE FLOOR PLAN FOR NEW 120 VOLT RECEPTACLE. RECEPTACLES, SWITGHES, ETC. IN STUD ACOUSTICAL TILE GEILIN6 SYSTEM. DATE: J—J14 SIZE AND DETAIL 12/A-I FOR ADDITIONAL INFORMATION. R = REMOVE, N = NEW, EX = EXISTING, THE SAME CAVITY. SPACE AT 24" O.G. MIN. 5/8' HREGODE G.W.B. - BOTH SIDES �® WALL TYPE - SEE 'WALL TYPES AND DETAILS,' DRAWING A-2, FOR ADDITIONAL INFORMATION. 6FI =GROUND FAULT INTERRUPTED , hYPE 'MRX' ON NET' WALLS - WASTE 4 g SCALE: 1/8" = V-0" M015TLRE AND MOLD RE515TANT) BASKET O DOOR NIMBER -SEE DOOR SGFEDULE SHEET A 2. ,H, (� T"TD NEK DEDICATED, GROUNDED 20 AMP QUAD, MARKED WITH ORANGE DEVICE. VERIFY EXISTING STUD TYPE BEFORE ORDERING MATERIALS 6' FRIGTION-FIT, FIBERGL.A55 (FS 25, SHEET TITLE: O ROOM 516NA6E - SE=E 516NA6E 50HEDULE 5fEET A-2. ,µ, + QUADRAPLEX RECEPTACLE, 501<450), METAL STUD SOUND BATTS ARE TO BE INSTALLED IN ALL TYPE 1D SIDE VIEW FRONT VIEW PLAN Y Y CONCRETE FLOOR SLAB PARTITIONS. Gi�llll DE7AILS 4 5GH. In" SPACE (TYP) ® NEW CEILING MOUNTED LED EXIT SIGN WITH 1-112 HOUR BATTERY NEW JUNCTION BOX. k RATED WALL5 - PROVIDE A ONE-HOUR SHEET No. BACK-W. r FIRE RATED PARTITION WHERE BARRIER FREE 5. 5. 5EMI-REGE55ED PAPER BARRIER FREE PAPER TOWEL T5 AD.A. COMPLIANT TRANSITION STRIP. SEE DETAIL 6/A-2. NEW WALL MOUNTED LED. EXIT SIGN WITH I In HOUR BATTERY ® ELECTRICAL (FLAT WIRE). / OHIW6UL ON THE FLOOR PLANS BY FOLLOWING UL DESIGN NO. U-465 TOWEL DISPENSER 4 WASTE ELEV. DISPENSER ELEVATION COORDINATE PTD WITH OWNER A -2 BAGKHJP AND EMERGENCY LIGHTING HEADS. SYMBOL o— M N AGK- UP. BIGY LIGHTING FIXTURE WITH I-112 HOUR BATTERY # A# # DRAWING NUMBER DETAIL FUMBER INTERIOR ELEVATION SYMBOL. SECTION MARK. HALL I 1 PE O2 - ONE HOUR FIRE I Y TED FIXTURE MOUNTING HEIGHTS � #C� DETAIL NUMBER I A-2 NTS _ NT5 rc d 14180 0 u 2T-5 5,1} ' 151-10 3/611 (CL TOL) (GL TO GL) I (CL TO GU U I�1 i (GL TO GL,1 i FUTURE TEMff SPACE ERT i i Iv� O^ OLL: REMOV O i i TO GU SCALE: 1/8' = I'-0' 1 REMQVAL REFLECTED GE I L I N6 PLAN -v SCALE: AV _ I. REMOVE ALL EXI5TIN65 FLOOR FINISHES. EXISTING CONCRETE FLOOR TO REMAIN: PROVIDE SMOOTH GLEAN LEVEL 5LAB READY FOR FUTURE TENANT FLOORING, MAXIMUM DEVIATION OF FLOOR SLAB I/4' OVER 10'-0" AND I" OVER ENTIRE SLAB. FLOOR 5LAB SHALL BE REASONABLY FREE OF HORIZONTAL DEFLEGTIONS, RI06E5, LEVEL GHAN6E5, H16H POINTS OR 5TEP5 2. EXISTING CONCRETE SIDEWALK TO REMAIN, NOT IN SCOPE 3. EXISTING DOOR TO REMAIN 4. EXI5TI% STOREFRONT SYSTEM TO BE REMOVED 5. EXISTING TENANT DEMISING WALL TO REMAIN. PATGH AND REPAIR EXISTING GVIB FIN;5H AND PROVIDE READY TO RECEIVE FUTURE TENANT FIN15H 6. EXI5TINKi COLUMN TO REMAIN, PATCH AND REPAIR EXI5TIN6 606 FIN15H AND PROVIDE READY TO RECEIVE FUTURE TENANT FIN15H 1. EXI5TI% PAIR OF STOREFRONT DOOR5 TO BE REMOVED, PREPARE TO INFILL EXI5TIN6 TENANT DEMISIN6 WALL.. MAINTAIN E&RE55 THROUGHOUT CONSTRUCTION. 8. EXI5TIN6 MEGHANIGAL SYSTEM TO BE REUSED. SEE MEGHANIGAL DOCUMENTS (8Y OTHERS) FOR SCOPE, DETAILS AND SPECIFICATIONS. q. EXISTING PLUMBIN6 TO BE GAPPED AT FLOOR AS REQUIRED TO ACCOMMODATE NEW FLOOR FINIS! SEE PLUMBIN6 DOGUMiENTS (BY OTHERS) FOR SCOPE, 5PEGIFIGATION5 AND DETAILS. 10. EXI5TTN6 TOILET ROOM TO BE REMOVED. EXI5TIN6 PLUMBIN6 TO BE GAPPED AT FLOOR AS REQUIRED TO ACCOMMODATE NEW FLOOR FIN15HE5. 5EE PLUMBING DOWMENT5 (BY OTHERS) FOR SCOPE, SPECIFICATIONS AND DETAIL5. 5EE DETAIL 3/R-1 FOR SLAB RECONSTRUCTION. II. REMOVE ALL EXI5TIN6 INTERIOR PARTITIONS, FLOOR TO UNDER51DE OF 5TRUGTIIRE, AND PATCH AND REPAIR FLOOR AND EXISTIN6 6WB AT EXI5TTN6 DEM151% WALL5 TO ACCOMMODATE NEW WORK. 12. EXISTING ELECTRIC PANEL TO REMAIN. SEE ELECTRICAL DOGIMENT5 (BY OTHERS) FOR 5C,OPE, SPECIFICATIONS AND DETAILS. 13. EXI5TIN6 METAL DOOR AND HARDWARE TO BE REPLACED. 14. EXISTING MOP SINK TO BE REMOVED. GAP PLUMBING AT FLOOR TO AGGOMMOV/,TE RJIURE TENANT FLOOR FINISH 15. EXISTING 40 GAL. HOT WATER HEATER TO REMAIN. SEE PLumaINS DOCUMENTS 0 i f OT ERS) FOR 5GOPE, SPEGIFIGATiONS AND DETAIL5. 16. REVIEW SCOPE OF FLOOR FINISH DEMO WITH OWNER PRIOR TO ANY WORK KEYED GEILIN6 REMOVAL NOTES: X I. REMOVE ALL EXI5TI% GRIDS, TILES, LI&HT5 ETG. 2. EXI5TIN6 EMERGENCY EXIT 516N TO REMAIN 3. REMOVE EXI5TIN6 EXIT 516N. 4. RELOCATE EXI5TIN6 EXIT 516N. 5. REMOVE EXISTIN6 BULKHEAD, PATCH AND REPAIR EXISTING 6HB WHERE NEGE55ARY TO ACCOMMODATE NEW FINISHES. 6. REMOVE EXISTIN6 VENT. PATCH AND REPAIR ALL ROOF PENETRATIONS PER ROOFIN6 MANUFACTURERS SPECIFICATIONS. 1. EXISTING CEILING TO REMAIN. PATCH AND REPAIR A5 REQUIRED TO AGGOMMODATE NEW WORK. 8. EXISTIN6 MECHANICAL SYSTEM TO BE REUSED. SEE PLUMBING DOCUMENTS (BY OTHERS) FOR SCOPE, DETAILS AND SPEGIFIGATION5. OGGUPANT DISRUPTION: THI5 BUILDIN6 15 OCGUPIED. ALL CONTRACTORS SHALL KEEP 015RUPTION TO OCCUPANTS TO A MINIMUM. GOORDINATE TIMES OF GON5TRUCTION WITH THE OWNER. SEE GLEANIN6 NOTES ON N -I FOR FURTHER INFORMATION REGARDING OGGUPANT DISRUPTION. THE CONTRACTOR SHALL MAINTAIN ALL EXITS DURIN6 ALL TIMES. SEE EXIT AND EMER&ENGY LIGHTING NOTE ON THIS SHEET FOR ADDITIONAL INFORMATION. 5TORED AND 5TOGKPILED ITEM5: I. PROTECT ALL REMOVED ITEMS SCHEDULED TO BE 5TOCKPILED WITH CARDBOARD, BUBBLE WRAP, ETG., TO PREVENT DAMA6E. 2. LABEL ALL STOCKPILED ITEMS. 3. REMOVE ALL STOCKPILED ITEMS FROM THE 51TE AND TRANSPORT AND STORE AT LOCATION ON THE CAMPUS AS DIRECTED BY THE COLLEGE. 4. PROVIDE THE COLLE67E WITH A SCHEDULE INVENTORYING ALL STOCKPILED ITEM5. PATCHING: I. INFILL 6A.B. TO MEET AND MATCH ADJACENT EXI5TIN6 AT REMOVED AND/OR ALTERED PARTITIONS, ABANDONED FASTENERS, ERS, ETC, Y+ETHER EXI5TIN6 OR DUE TO TI -E WORK OF THI5 PROJECT. FIN15H TAPE (INOLUDIN6 GORNERBEAD APPLICATION AT OUTSIDE GORNER5) AND PREPARE FOR SCHEDULED FIN15H(E5). 2. PATCH 6AB. AND OTHER FINISHES TO MEET AND MATCH ADJACENT EXI5TIN6 AT MECHANICAL, PL"IN6, ELECTRICAL, FIRE ALARM AND FIRE 5UPPRE55ION REMOVALS AND PREPARE FOR SCHEDULED FINI511(E5). COORDINATE WITH THE M/P/EJFA/F5 CONTRACTORS. A5BE5T05 GONTAININO MATERIAL AGM THE ARCHITECT AND ITS GON5ULTANT5 ARE NOT RESPONSIBLE TO IDENTIFY, TEST, OR SPECIFY THE REMOVAL OF A5E3E5TO5 OR ASBESTOS CONTAININ6 MATERIALS. THESE DRAWI%5 DO NOT CONTAIN AN A5BE5T05 SURVEY OR ASBEEW5 A13ATEMENT INFORMATION. IT 15 THE RESPONSIBILITY OF THE OWNER TO CONTRACT FOR AN A5BE5TO5 SURVEY BY A CERTIFIED IN5PECTOR TO DETERMINE WHETHER OR NOT THE BUILDING - OR PORTIONYS) THEREOF - TO BE DEMOLISHED, RENOVATED, ALTERED OR REPAIRED 00NTAINI5 PRESUMED A58E5TO5 GONTAININ6 MATERIALS (PACK, A55E5TO5 GONTAINI% MATERIALS (AGM), OR ASBESTOS MATERIAL IN COMPLIANCE WITH AEW HAMPSHIRE STATE RULES AND REGULATIONS. THE OWNER SHALL SUBMIT THE A55E5TO5 5URVEY TO THE CODE ENFORCEMENT OFFICIAL OF THE AUTHORITY HAVING JJR15010TION (AH4, THE ARCHITECT AND TO THE PROJECT CONTRACTOR. THE OWNER SHALL CONTRACT TO HAVE AGM, PAGM AND A513E5TO5 REMOVED FROM THE PRO -ECT AREA IN ACCORDANCE WITH ALL APPLICABLE GORE AND RE5ULATIONI5 INGLUDIN6, BUT NOT LIMITED TO, THE FOLLOWING: U5EPA: 40 GFR PART 61, 40 GFR PART 163 05HA: 2g GFR 1910.1001, 2g GFR 1826.1101 THE ASBESTOS ABATEMENT (REMOVAL AND LL&AL DISPOSAL) SHALL BE COMPLETED PRIOR TO THE COMMENCEMENT OF ANY OF THE DEMOLITION, RENOVATION OR G0145TRUGTTON WORK OF THIS PROJEGT. ONCE ALL REGULATED ABATEMIEINT WORK HA5 BEEN COMPLETED, THE COMPLETED "ASBESTOS PROJECT CERTIFICATE OF COMPLETION' SHALL BE SENT, BY THE OWNER TO THE GORE ENFORCEMENT OFFICIAL OF THE AW, THE ARCHITECT AND THE CONTRACTORS. LOUD N015E5: THE CONTRACTOR SHALL COORDINATE WITH THE TENANT FOR TIMES WHEN MAKIN6 LOUD N015E 15 ACCEPTABLE OR SHALL SCHEDULE THI5 TYPE OF WORK DURIN6 NON-6U51NE55 HOURS. "DIG 5AFELY NEYv YORK": AS PER NY5 CODE RULE 153, THE CONTRACTOR AND ALL 51,113-GONTRAGTOR5 SHALL PROVIDE DUE AND TIMELY NOTICE TO '0I6 SAFELY NEW YORK', FORMERLY "UNDERGROUND FAGILITIE5 PROTECTIVE ORGANIZATION" ("UFPO'), AT 1(800)q62-1962 OR 811 AT LEAST TWO BUT NO MORE THAN TEN WORKING DAYS, NOT INGLUOIN6 THE DATE OF EXCAVATION OR DEMOLITION (INGLUDIN6 DRILLING, DRIVIW6 P05T5, ETCJ. THE GONTRAGTOR SHALL GOMPLY WITH ALL REQUIREMENTS OF NYS, CODE RULE 153. UPON DISCOVERY OF UNKNOWN UNDER61ROUND FAGILITIE5, CABLING, ETC. WORK IN THAT AREA SHALL CEASE. NOTIFY UFPO, OWNER AND ARCHITECT IMMEDIATELY. DO NOT PROCEED WITH WORK UNTIL RECEIVING WRITTEN DIRECTION TO DO 50 FROM OWNERS PRO.EGT REPRESENTATIVE. GALL qII IMMEDIATELY IF ANY UTILITIE5 ARE ACCIDENTALLY HIT. NEW t EXI5TIN6 FIRE RATED HALL PENETRATION5: ALL PENETRATIONS THROU6H FIRE RATED WALLS SHALL BE MADE FIRE AND SMOKE T16HT USIN6 U.L. APPROVED METHODS AND MATERIALS (INGLUDIN6 FIRE DAMPER5 WHERE APPROPRIATE). PREPARATION FOR GUTTING: PRIOR TO GU171N6, GORE DRILLING, FA6TENIN6 INTO, ETG. ALL CONTRACTORS SHALL THOROU6HLY EXAMINE THE EXISTING WALL / FLOOR AND CEILING CONSTRUCTION FOR EXISTING CONDUITS, GABLES, PIPING AND STRUCTURAL ITEMS, TO ANY EXTENT NECESSARY TO AVOID THE ACCIDENTAL CUTTING OF MECHANICAL OR STRUCTURAL ITEMS WITHIN EXI57IN6 GON5TRUCTION. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR THE CUTTIN6 OF ANY EXISTING CONDUIT, GABLE, PIPE, STRUCTURAL MEMBERS, ETC. THAT 15 SCHEDULED TO REMAIN. PROTECTION OF EXI5TIN6 ITEMS: ALL ITEMS IDENTIFIED A5 EXI5TIN6 ARE SCHEDULED TO REMAIN UNLE55 SPECIFICALLY NOTED OTHERWISE AND SHALL BE FULLY PROTECTED FROM ANY DELETERIOUS EFFECT DURING ALL PHA5E5 OF THE PRO_EGT. ANY DAMAGE TO EXISTING ITEMS (WHETHER THEY ARE SHOWN ON DRAWINGS OR NOT) SHALL BE CORRECTED TO THE SATISFACTION OF THE OWNER AT THE EXPENSE OF THE GONTRAGTCR. GENERAL REMOVAL NOTE5: I. EXAMINE THE DRAWINGS AND THE AREAS AND CONDITIONS WHERE REMCVALS WORK SHALL BE PERFORMED AND CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER GOMPLETION OF WORK - DO NOT PROCEED UNTIL UNSATISFACTORY GONDITION5 ARE GORRECTED. 2. PREPARE, AND FOLLOW, AN ORGANIZED PLAN FOR 5ELEGTIVE DEMOLITION AND REMOVAL OF ITEMS. REMOVAL PHASES SHALL 13E COORDINATED WITH PROPOSED CONSTRUCTION AND RENOVATION WORK. REMOVALS WORK SHALL NOT EE61N UNTIL A PHASING PLAN HAS BEEN APPROVED (IN WRITING) BY CONSTRUCTION MANA6ER, PLUMBER, ELECTRIGIAN AND HVAC. GONIRACTOR < APPROVED BY THE OWNER. ALL ELECTRICAL REMOVALS AND SHUT DOWNS SHALL BE PROVIDED BY A LICENSED ELEGTRIGAL CONTRACTOR- 5. ONTRACTOR3. PRIOR TO GOMMENGIN6 REMOVAL5 WORK, AND UNTIL SUCH TIME THAT FINAL WORK 15 IN PLACE, CONTRACTOR SHALL ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRAGIN5, 5HORIN6 AND OTHER TEMPORARY SYSTEM5 OF SUPPORT NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION WHIGH 15 SCHEDULED TO REMAIN. 4. SHUT OFF, GAP AND OTHERWI5E PROTEG f EXISTING UTILITIES IN STRICT AGGORDANGE WITH THE REQUIREMENTS OF THE PU13LIG A6ENGIE5 OR UTILITIES HAVING JJR15DICTION AND A5 DIREGTED ON THE MECHANICAL AND ELEGTRIGAL DRAWINGS. 5. ALL ELEGTRIGAL SHUT DOWNS AND REMOVAL5 5HA'1 BE PERFORMED BY A LICENSED FI FrTRICIAN. 6. COMPLETELY REMOVE ITEMS 5GHEDULED TO BE DEMOLISHED AND REMOVED, LEAVING SURFAGE5 GLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED EL5EWHERE. 1. DEMOL15HED MATERIALS SHALL BE GOMPLETT3Y REMOVED FROM THE JOB SITE AND DISPOSED OF PROPERLY ON A DAILY BA5E5 UNLE55 OTHERWISE DIREGTED BY OWNER. 8. ALL REMOVAL5 INDIGATED MAY REQUIRE THE GOORDINATED REMOVAL OF EX15TIWo MEGHANIGAL, El TRIGAL, SECURITY SYSTEM, FIRE ALARM SYSTEM, DATA AND TELEPHONE 5Y5TEM AND PLUMBIN6 EQUIPMENT AND LINES -REFER TO MECHANICAL AND ELECTRICAL DRAWIN65 (PREPARED BY OTHERS) FOR INFORMATION RE6ARDING EXISTING AND NEW H.VA.G., PLUMBIN(5, ELECTRICAL ETC., RELATED WORK PRIOR TO GOMI-ENOING DEMOLITION. q. COORDINATE ALL PARTIAL PARTITION REMOVAL DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION TAKING PLAGE. EXISTING SLAB CONCRETE INFILL #4 REBAR DOVEL (1'-0" LONG) AT 16' O.G. a a n Q Z W a m WF�y e 'u w W-4� OF �IZ LL O � � y irl 4I i i i FUTURE TEMff SPACE ERT i i Iv� O^ OLL: REMOV O i i TO GU SCALE: 1/8' = I'-0' 1 REMQVAL REFLECTED GE I L I N6 PLAN -v SCALE: AV _ I. REMOVE ALL EXI5TIN65 FLOOR FINISHES. EXISTING CONCRETE FLOOR TO REMAIN: PROVIDE SMOOTH GLEAN LEVEL 5LAB READY FOR FUTURE TENANT FLOORING, MAXIMUM DEVIATION OF FLOOR SLAB I/4' OVER 10'-0" AND I" OVER ENTIRE SLAB. FLOOR 5LAB SHALL BE REASONABLY FREE OF HORIZONTAL DEFLEGTIONS, RI06E5, LEVEL GHAN6E5, H16H POINTS OR 5TEP5 2. EXISTING CONCRETE SIDEWALK TO REMAIN, NOT IN SCOPE 3. EXISTING DOOR TO REMAIN 4. EXI5TI% STOREFRONT SYSTEM TO BE REMOVED 5. EXISTING TENANT DEMISING WALL TO REMAIN. PATGH AND REPAIR EXISTING GVIB FIN;5H AND PROVIDE READY TO RECEIVE FUTURE TENANT FIN15H 6. EXI5TINKi COLUMN TO REMAIN, PATCH AND REPAIR EXI5TIN6 606 FIN15H AND PROVIDE READY TO RECEIVE FUTURE TENANT FIN15H 1. EXI5TI% PAIR OF STOREFRONT DOOR5 TO BE REMOVED, PREPARE TO INFILL EXI5TIN6 TENANT DEMISIN6 WALL.. MAINTAIN E&RE55 THROUGHOUT CONSTRUCTION. 8. EXI5TIN6 MEGHANIGAL SYSTEM TO BE REUSED. SEE MEGHANIGAL DOCUMENTS (8Y OTHERS) FOR SCOPE, DETAILS AND SPECIFICATIONS. q. EXISTING PLUMBIN6 TO BE GAPPED AT FLOOR AS REQUIRED TO ACCOMMODATE NEW FLOOR FINIS! SEE PLUMBIN6 DOGUMiENTS (BY OTHERS) FOR SCOPE, 5PEGIFIGATION5 AND DETAILS. 10. EXI5TTN6 TOILET ROOM TO BE REMOVED. EXI5TIN6 PLUMBIN6 TO BE GAPPED AT FLOOR AS REQUIRED TO ACCOMMODATE NEW FLOOR FIN15HE5. 5EE PLUMBING DOWMENT5 (BY OTHERS) FOR SCOPE, SPECIFICATIONS AND DETAIL5. 5EE DETAIL 3/R-1 FOR SLAB RECONSTRUCTION. II. REMOVE ALL EXI5TIN6 INTERIOR PARTITIONS, FLOOR TO UNDER51DE OF 5TRUGTIIRE, AND PATCH AND REPAIR FLOOR AND EXISTIN6 6WB AT EXI5TTN6 DEM151% WALL5 TO ACCOMMODATE NEW WORK. 12. EXISTING ELECTRIC PANEL TO REMAIN. SEE ELECTRICAL DOGIMENT5 (BY OTHERS) FOR 5C,OPE, SPECIFICATIONS AND DETAILS. 13. EXI5TIN6 METAL DOOR AND HARDWARE TO BE REPLACED. 14. EXISTING MOP SINK TO BE REMOVED. GAP PLUMBING AT FLOOR TO AGGOMMOV/,TE RJIURE TENANT FLOOR FINISH 15. EXISTING 40 GAL. HOT WATER HEATER TO REMAIN. SEE PLumaINS DOCUMENTS 0 i f OT ERS) FOR 5GOPE, SPEGIFIGATiONS AND DETAIL5. 16. REVIEW SCOPE OF FLOOR FINISH DEMO WITH OWNER PRIOR TO ANY WORK KEYED GEILIN6 REMOVAL NOTES: X I. REMOVE ALL EXI5TI% GRIDS, TILES, LI&HT5 ETG. 2. EXI5TIN6 EMERGENCY EXIT 516N TO REMAIN 3. REMOVE EXI5TIN6 EXIT 516N. 4. RELOCATE EXI5TIN6 EXIT 516N. 5. REMOVE EXISTIN6 BULKHEAD, PATCH AND REPAIR EXISTING 6HB WHERE NEGE55ARY TO ACCOMMODATE NEW FINISHES. 6. REMOVE EXISTIN6 VENT. PATCH AND REPAIR ALL ROOF PENETRATIONS PER ROOFIN6 MANUFACTURERS SPECIFICATIONS. 1. EXISTING CEILING TO REMAIN. PATCH AND REPAIR A5 REQUIRED TO AGGOMMODATE NEW WORK. 8. EXISTIN6 MECHANICAL SYSTEM TO BE REUSED. SEE PLUMBING DOCUMENTS (BY OTHERS) FOR SCOPE, DETAILS AND SPEGIFIGATION5. OGGUPANT DISRUPTION: THI5 BUILDIN6 15 OCGUPIED. ALL CONTRACTORS SHALL KEEP 015RUPTION TO OCCUPANTS TO A MINIMUM. GOORDINATE TIMES OF GON5TRUCTION WITH THE OWNER. SEE GLEANIN6 NOTES ON N -I FOR FURTHER INFORMATION REGARDING OGGUPANT DISRUPTION. THE CONTRACTOR SHALL MAINTAIN ALL EXITS DURIN6 ALL TIMES. SEE EXIT AND EMER&ENGY LIGHTING NOTE ON THIS SHEET FOR ADDITIONAL INFORMATION. 5TORED AND 5TOGKPILED ITEM5: I. PROTECT ALL REMOVED ITEMS SCHEDULED TO BE 5TOCKPILED WITH CARDBOARD, BUBBLE WRAP, ETG., TO PREVENT DAMA6E. 2. LABEL ALL STOCKPILED ITEMS. 3. REMOVE ALL STOCKPILED ITEMS FROM THE 51TE AND TRANSPORT AND STORE AT LOCATION ON THE CAMPUS AS DIRECTED BY THE COLLEGE. 4. PROVIDE THE COLLE67E WITH A SCHEDULE INVENTORYING ALL STOCKPILED ITEM5. PATCHING: I. INFILL 6A.B. TO MEET AND MATCH ADJACENT EXI5TIN6 AT REMOVED AND/OR ALTERED PARTITIONS, ABANDONED FASTENERS, ERS, ETC, Y+ETHER EXI5TIN6 OR DUE TO TI -E WORK OF THI5 PROJECT. FIN15H TAPE (INOLUDIN6 GORNERBEAD APPLICATION AT OUTSIDE GORNER5) AND PREPARE FOR SCHEDULED FIN15H(E5). 2. PATCH 6AB. AND OTHER FINISHES TO MEET AND MATCH ADJACENT EXI5TIN6 AT MECHANICAL, PL"IN6, ELECTRICAL, FIRE ALARM AND FIRE 5UPPRE55ION REMOVALS AND PREPARE FOR SCHEDULED FINI511(E5). COORDINATE WITH THE M/P/EJFA/F5 CONTRACTORS. A5BE5T05 GONTAININO MATERIAL AGM THE ARCHITECT AND ITS GON5ULTANT5 ARE NOT RESPONSIBLE TO IDENTIFY, TEST, OR SPECIFY THE REMOVAL OF A5E3E5TO5 OR ASBESTOS CONTAININ6 MATERIALS. THESE DRAWI%5 DO NOT CONTAIN AN A5BE5T05 SURVEY OR ASBEEW5 A13ATEMENT INFORMATION. IT 15 THE RESPONSIBILITY OF THE OWNER TO CONTRACT FOR AN A5BE5TO5 SURVEY BY A CERTIFIED IN5PECTOR TO DETERMINE WHETHER OR NOT THE BUILDING - OR PORTIONYS) THEREOF - TO BE DEMOLISHED, RENOVATED, ALTERED OR REPAIRED 00NTAINI5 PRESUMED A58E5TO5 GONTAININ6 MATERIALS (PACK, A55E5TO5 GONTAINI% MATERIALS (AGM), OR ASBESTOS MATERIAL IN COMPLIANCE WITH AEW HAMPSHIRE STATE RULES AND REGULATIONS. THE OWNER SHALL SUBMIT THE A55E5TO5 5URVEY TO THE CODE ENFORCEMENT OFFICIAL OF THE AUTHORITY HAVING JJR15010TION (AH4, THE ARCHITECT AND TO THE PROJECT CONTRACTOR. THE OWNER SHALL CONTRACT TO HAVE AGM, PAGM AND A513E5TO5 REMOVED FROM THE PRO -ECT AREA IN ACCORDANCE WITH ALL APPLICABLE GORE AND RE5ULATIONI5 INGLUDIN6, BUT NOT LIMITED TO, THE FOLLOWING: U5EPA: 40 GFR PART 61, 40 GFR PART 163 05HA: 2g GFR 1910.1001, 2g GFR 1826.1101 THE ASBESTOS ABATEMENT (REMOVAL AND LL&AL DISPOSAL) SHALL BE COMPLETED PRIOR TO THE COMMENCEMENT OF ANY OF THE DEMOLITION, RENOVATION OR G0145TRUGTTON WORK OF THIS PROJEGT. ONCE ALL REGULATED ABATEMIEINT WORK HA5 BEEN COMPLETED, THE COMPLETED "ASBESTOS PROJECT CERTIFICATE OF COMPLETION' SHALL BE SENT, BY THE OWNER TO THE GORE ENFORCEMENT OFFICIAL OF THE AW, THE ARCHITECT AND THE CONTRACTORS. LOUD N015E5: THE CONTRACTOR SHALL COORDINATE WITH THE TENANT FOR TIMES WHEN MAKIN6 LOUD N015E 15 ACCEPTABLE OR SHALL SCHEDULE THI5 TYPE OF WORK DURIN6 NON-6U51NE55 HOURS. "DIG 5AFELY NEYv YORK": AS PER NY5 CODE RULE 153, THE CONTRACTOR AND ALL 51,113-GONTRAGTOR5 SHALL PROVIDE DUE AND TIMELY NOTICE TO '0I6 SAFELY NEW YORK', FORMERLY "UNDERGROUND FAGILITIE5 PROTECTIVE ORGANIZATION" ("UFPO'), AT 1(800)q62-1962 OR 811 AT LEAST TWO BUT NO MORE THAN TEN WORKING DAYS, NOT INGLUOIN6 THE DATE OF EXCAVATION OR DEMOLITION (INGLUDIN6 DRILLING, DRIVIW6 P05T5, ETCJ. THE GONTRAGTOR SHALL GOMPLY WITH ALL REQUIREMENTS OF NYS, CODE RULE 153. UPON DISCOVERY OF UNKNOWN UNDER61ROUND FAGILITIE5, CABLING, ETC. WORK IN THAT AREA SHALL CEASE. NOTIFY UFPO, OWNER AND ARCHITECT IMMEDIATELY. DO NOT PROCEED WITH WORK UNTIL RECEIVING WRITTEN DIRECTION TO DO 50 FROM OWNERS PRO.EGT REPRESENTATIVE. GALL qII IMMEDIATELY IF ANY UTILITIE5 ARE ACCIDENTALLY HIT. NEW t EXI5TIN6 FIRE RATED HALL PENETRATION5: ALL PENETRATIONS THROU6H FIRE RATED WALLS SHALL BE MADE FIRE AND SMOKE T16HT USIN6 U.L. APPROVED METHODS AND MATERIALS (INGLUDIN6 FIRE DAMPER5 WHERE APPROPRIATE). PREPARATION FOR GUTTING: PRIOR TO GU171N6, GORE DRILLING, FA6TENIN6 INTO, ETG. ALL CONTRACTORS SHALL THOROU6HLY EXAMINE THE EXISTING WALL / FLOOR AND CEILING CONSTRUCTION FOR EXISTING CONDUITS, GABLES, PIPING AND STRUCTURAL ITEMS, TO ANY EXTENT NECESSARY TO AVOID THE ACCIDENTAL CUTTING OF MECHANICAL OR STRUCTURAL ITEMS WITHIN EXI57IN6 GON5TRUCTION. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR THE CUTTIN6 OF ANY EXISTING CONDUIT, GABLE, PIPE, STRUCTURAL MEMBERS, ETC. THAT 15 SCHEDULED TO REMAIN. PROTECTION OF EXI5TIN6 ITEMS: ALL ITEMS IDENTIFIED A5 EXI5TIN6 ARE SCHEDULED TO REMAIN UNLE55 SPECIFICALLY NOTED OTHERWISE AND SHALL BE FULLY PROTECTED FROM ANY DELETERIOUS EFFECT DURING ALL PHA5E5 OF THE PRO_EGT. ANY DAMAGE TO EXISTING ITEMS (WHETHER THEY ARE SHOWN ON DRAWINGS OR NOT) SHALL BE CORRECTED TO THE SATISFACTION OF THE OWNER AT THE EXPENSE OF THE GONTRAGTCR. GENERAL REMOVAL NOTE5: I. EXAMINE THE DRAWINGS AND THE AREAS AND CONDITIONS WHERE REMCVALS WORK SHALL BE PERFORMED AND CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER GOMPLETION OF WORK - DO NOT PROCEED UNTIL UNSATISFACTORY GONDITION5 ARE GORRECTED. 2. PREPARE, AND FOLLOW, AN ORGANIZED PLAN FOR 5ELEGTIVE DEMOLITION AND REMOVAL OF ITEMS. REMOVAL PHASES SHALL 13E COORDINATED WITH PROPOSED CONSTRUCTION AND RENOVATION WORK. REMOVALS WORK SHALL NOT EE61N UNTIL A PHASING PLAN HAS BEEN APPROVED (IN WRITING) BY CONSTRUCTION MANA6ER, PLUMBER, ELECTRIGIAN AND HVAC. GONIRACTOR < APPROVED BY THE OWNER. ALL ELECTRICAL REMOVALS AND SHUT DOWNS SHALL BE PROVIDED BY A LICENSED ELEGTRIGAL CONTRACTOR- 5. ONTRACTOR3. PRIOR TO GOMMENGIN6 REMOVAL5 WORK, AND UNTIL SUCH TIME THAT FINAL WORK 15 IN PLACE, CONTRACTOR SHALL ASCERTAIN REQUIREMENTS FOR, AND PROVIDE, BRAGIN5, 5HORIN6 AND OTHER TEMPORARY SYSTEM5 OF SUPPORT NEEDED TO PREVENT DAMAGE TO EXISTING CONSTRUCTION WHIGH 15 SCHEDULED TO REMAIN. 4. SHUT OFF, GAP AND OTHERWI5E PROTEG f EXISTING UTILITIES IN STRICT AGGORDANGE WITH THE REQUIREMENTS OF THE PU13LIG A6ENGIE5 OR UTILITIES HAVING JJR15DICTION AND A5 DIREGTED ON THE MECHANICAL AND ELEGTRIGAL DRAWINGS. 5. ALL ELEGTRIGAL SHUT DOWNS AND REMOVAL5 5HA'1 BE PERFORMED BY A LICENSED FI FrTRICIAN. 6. COMPLETELY REMOVE ITEMS 5GHEDULED TO BE DEMOLISHED AND REMOVED, LEAVING SURFAGE5 GLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS SPECIFIED EL5EWHERE. 1. DEMOL15HED MATERIALS SHALL BE GOMPLETT3Y REMOVED FROM THE JOB SITE AND DISPOSED OF PROPERLY ON A DAILY BA5E5 UNLE55 OTHERWISE DIREGTED BY OWNER. 8. ALL REMOVAL5 INDIGATED MAY REQUIRE THE GOORDINATED REMOVAL OF EX15TIWo MEGHANIGAL, El TRIGAL, SECURITY SYSTEM, FIRE ALARM SYSTEM, DATA AND TELEPHONE 5Y5TEM AND PLUMBIN6 EQUIPMENT AND LINES -REFER TO MECHANICAL AND ELECTRICAL DRAWIN65 (PREPARED BY OTHERS) FOR INFORMATION RE6ARDING EXISTING AND NEW H.VA.G., PLUMBIN(5, ELECTRICAL ETC., RELATED WORK PRIOR TO GOMI-ENOING DEMOLITION. q. COORDINATE ALL PARTIAL PARTITION REMOVAL DIMENSIONS WITH FLOOR PLAN PRIOR TO DEMOLITION TAKING PLAGE. EXISTING SLAB CONCRETE INFILL #4 REBAR DOVEL (1'-0" LONG) AT 16' O.G. a a n Q Z W a a WF�y e 'u w W-4� Fx y ru y irl W ,4 O lu r V EPDXY 6"INTO - EXI5TIN6 5LA13 IF EXI5TIN6 SLAB 15 MATCH EXISTING REINFORGIN6 (6 X 6 1142A X 1042A MINIMUM) O `-- PROVIDE A VAPOR RETARDER THAT MATCHES EXISTING, TAPE SEAMS "FLOWABLE FILL" BACKFILL. COMPACTED NYSDOT ITEM #1 116" LIFTS,' DETAIL - TYP I GAL 5LAB REGON5TRUGTI ON SCALE: NOW W'LGGLR�W I'rR� �Yr llf�1 o z N Q Z W a 00 a a PI W A WF�y V V I.y 'u w W-4� Fx y ru y irl W ,4 O lu r V Y X a X �J ni Q Z O REVISIONS PROJECT No. 14180 DATE: J__/14 SCALE:I/8" = I'-0" SHEET TITLE: REMOVAL PLAN5 SHEET No. 14180