Loading...
RC-000165-2015TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000165-2015 Tax Map No: 252.4-2 RENEWED Permission is hereby granted to: THOMAS BARBER For property located at: 8 LOCKHART MOUNTAIN RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: THOMAS BARBER Single Family-Alteration 167,000.00 Owner Address: 8 Lockhart Mounain RD Total Value 167,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications Residential Addition 2097 s.f. Garage Addition 544 s.f. Permit Renewed on Tues.,September 6,2016: Pd$50 50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES:Thursday,June 15,2017 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of e vion& f"r 5 SIGNED BY: M'_' V/ I the Town of Queensbury. Director of Building&Code Enforcement Arm a ON TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000165-2015 lS - 2?e) Tax Map No: 252.-1-2 Permission is hereby granted to: THOMAS BARBER REVISED For property located at: 8 LOCKHART MOUNTAIN RD in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Address:Single Family-Alteration 167,000.00 Total Value 167,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency THOMAS BARBER 8 Lockhart Mounain RD Queensbury,NY 12804 Plans&Specifications PERMIT FEE PAID-TIES PERMIT EXPIRES: Wednesday,June 15,2016 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Monday,June 15,2015 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY i_Makk 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Flirj Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150228 Application Number: A20150228 Tax Map No: 523400-252-000-0001-002-000-0000 Permission is hereby granted to: NATALIE AND TOM BARBER For property located at: 8 LOCKHART Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: NATALIE AND TOM BARBER tion 8 LOCKHART MOUNTAIN Rd Residential AlterationAlte LAKE GEORGE,NY 12845-0000 Residential 167,000.00 Total Value 167,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2015-228 Residential Additions 2097 s.f. to SFD and 544 s.f. to detached garage 2641 total s.f. 528.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,June 15, 2016 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T n o eens ryA, ? , •, une 15,2015 14 SIGNED BY I for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only DATE v Y 20/5 Received v//'' Tax Map ID TAX MAP ID i/ . '- 2 ° EPer No. 2.015-Z2tia 02 2015 R ee e FD2. 20 ZONING 111f Site Plan# HISTORIC SITE Yes V No TOWN OF QUEE - Subdivision# B JILDING&CO SUBDIVISION NAME Lot# TOWN BD.RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWELLINGS,DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED & MODULAR HOMES,BUTNOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. APPLICANT 1dM 1534443.1S1' OWNER ADDRESS 8 ele. .iA " ,%1Z V• ec2 ADDRESS 44 e Vt' I2?1if 98) 36 3e.3k PHONE/E-MAIL PHONE/E-MAIL CONTRACTOR 4z:vc.e1 //L h,/S COST OF CONSTRUCTION(ESTIMATED): $ 4 Yi fj ADDRESS: cub/ L,z4A41,1- 44, Al j2BUILDING ADDRESS: gzz;e,--/Ader PHONE/E-MAIL Q/ ,[ CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: v'SH h'+k ode— '" PHONE rf(J—r`05 TYPE OF CONSTRUCTION Check ail that apply Please indicate measurements as required below New Addition Alteration 15'floor sq. ft. 2nd floor sq. ft. Total sq.ft. Height Single Family Yl I '377 ' 1Zo ' Si 0411* /!SW Two-Family Multi-Family of units Townhouse Business Office Retail - Mercantile Factory- Industrial Attached Garage of Other-- asrArre4403 4 60/46e 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business L fie' Proposed use of building or addition j(, i Source of heat (circle one) Gas Oil Tropane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? t O Are there easements on the property? 140t44 Nouot3 Site Information a. Dimensions or acreage of lot 3 ,GPS Ac-42-e4 b. Is this a corner lot? G•A«- `rj c. Will the grade be changed as a result of construction Yes /No d. Public water or Private well vitCM e. Sewer or Private Septic System 21 V/S•Te Value of all work to be performed (labor or materials) DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed,subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: R7,44 5 2/i/ C2 DATE tt/L/y,,--- SIGNATURE: DATE Co f2//j FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 V / N2AN /AResidential Plan Review: One & Two Family Dwellings Two (2) full sets of plans Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 90 Wind Floor Loads 40 psf north of Rt. 149 - 60)] 50 Ground Snow Load Sleeping Areas & Attics 30 psf Calculations Window schedule with glass size Door schedule / Main entrance 36" door Emergency Escape or Bedrooms and Habitable Space iAbove / Below grade: 5.7 sq. ft. Grade: 5.0 sq. ft. 24" (h) x 20" (w) minimum 44" maximum height above door Residential: Check paperwork compliance and Inspection checklist -Okay Driveway length: 300' or more -12' width required / 500' or more -turnaround required Foundation insulation to basement floor v Damp proofing / Waterproofing materials on plans tiAundation drainage on plans, if required 6" drop in 10' Exterior grade Framing cross section for each roof line, Vertical fire stopping every 10' where required ce & Snow Shield -24" inside exterior wall / 24" inside knee walls SEE c ter— Li1. Platforms at exterior doors p %:,6z) Stairway headroom 6'8"; all stairs 36" width Stair Run and Rise 1,.. 4\ Winder Run and Rise piral not allowed from 2nd story oke Detectors -battery backup and proper location interconnected Bathroom fixtures -proper clearance Hall width -36" width jt Handrails more than four risers on open sides Railing & Guards + 30" / Basement stairs included / Closed risers more than 4" in height rSafety glazing notes for required areas t3 Garage fire separation Garage floor sloped Attic access o3 E _‘") m p `_ 3 Roof over 30" -22" x 30" / Crawl spaces 18" x 24" access arbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' f sleeping area Soil Test results, if required Septic to well or water line separation All paperwork signed Note on plans energy saving light bulbs Blower door test agency paperwork 0 j floodplain Permit Required -Check Map p,s_ Truss ID Signage I O C 71- ELj G 1 1= Residential Plan Review -1 & 2 Family Dwellings 1-5-2015 CHECKLIST-SINGLE FAMILY PROJECT 11 Project name: 3Pe.ft '-r-4 geStOta.let iii C p REQUIRED-2 sets of the following documentation Yes No N/A 1. Building permit application completed 1 2. Energy Code inspector's report from REScheck 3. Septic alteration (if applicable) 4. Solid Fuel Burning or Gas Appliance form (if applicable) 5. Driveway Permit 6. Structural Drawings j a. Floor plans b. Foundation plan c. Cross Sections d. Elevations e. Window & Door Schedule f. Natural Light, Ventilation and Emergency Egress g. Plans signed/sealed by registered architect or engineer 7. Plot plans: indicate proposed structure, showing setback dimension from all surveyed property lines a. Show location of all existing structures on property b. Show location of water supply (well or water lines) c. Show location and configuration of septic disposal system or sewer line 8. Electrical inspection agency selected j CHECKLIST- MULTIPLE DWELLING/COMMERCIAL Project Name: REQUIRED-2 sets of the following documentation Yes No , N/A 1. Building permit application completed 2. Energy Code COMcheck and inspector's report form 3. Septic alteration (if applicable) 4. Solid Fuel Burning or Gas Appliance form (if applicable) 5. Driveway Permit 6. Structural Drawings a) Floor plans b) Foundation plan c) Cross Sections d) Elevations e) Design loads including floor, snow load and wind load f) Seismic design g) Plans signed and sealed by registered architect or engineer h) Window& Door Schedule 7. Plot plan—indicate proposed structure, showing setback dimension from all surveyed property lines a) Show location of ail existing structures on property b) Show location of water supply(well or water lines) c) Show location and configuration of septic disposal system or sewer fine 8. Electrical inspection agency selected 4 Town of Queensbury Building&Codes Principal Structure Application July 2014 Office Use Only FUEL BURNING APPLICANCE & CHIMNEY APPLICATIONReceived ax Map ID 4 7 X11 met No. Lti I S DATE ermit Fee TAX MAP ID 262. — / I;1 3 t it 0 2 2015 TOWN OF QUEENSBURY ZONING 5A DING&CODES OWNER: 727 j PHONE/E-MAIL 5 -&g--ao2. ADDRESS ea 4 F /4 Al /2641, INSTALLER/BUILDER. r-/,e`t /t s.6 Lrv 2A5 £41if PHONE/E-MAIL 6) J 3c7 -3c.. 3P ADDRESS: Lo,, hn2.f /i14, E J, ; CT /Lf-i , /v` ` /2 Yom,) *1'6-J°Udvc-7 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: )Ve4154'4t PHONE 6 1 (1- fieWBUILDINGADDRESS: 86 Mi / /r• t 14t0 6• 0 NYY afW,a Fuel Burning Appliance Information Wood Coal Pellet Gas Oil NOTE: ROUGH-IN & FINAL Stove INSPECTIONS ARE REQUIRED. Fireplace Insert Fireplace, Factory built' Fireplace, Masonry Furnace (Garage Only) If Factory built provide manufacturer name: 0164 fZSnite- ; model#: 3716- Listed X 6- Listed by:Number: Chimney Information Masonry** (check one) Block Brick Stone Flue Tie Steel Size in inches Material Double wall Triple wall Insulated VDirect Vent Chimney Liner If Non-masonry provide manufacturer name: model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention& Building Code and I or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I have read and agree to the above: Print Name: Date: 1/2/1, SignatureDate: 0-bj 5 Town of Queensbury Building&Codes Principal Structure Application July 2014 REScheck Software Version 4.6.1 Compliance Certificate Project Addition to Single Family Residence Energy Code: 2010 New York Energy Conservation 2015 Location: Warren County, New York Construction Type: Single-family IiE_ENSSURY Project Type: Addition Orientation: Bldg. faces 135 deg. from North Climate Zone: 6 (7635 HDD) Permit Date: FILECOPY Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 8 Lockhart Mountain Road Tom&Natalie Barber Ethan Peter Hall Queensbury,NY 12804 8 Lockhart Mountain Road Rucinski Hall Architecture Lake George,NY 12845 627 Maple Ave Saratoga Springs, NY 12866 518-580-1905 ephall@nycap.rr.com Compliance: Compliance: 7.5%Befter Than Code Maximum UA: 295 Your UA: 273 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-of rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. U-Factor UA Ceiling 1: Raised or Energy Truss 658 38.0 0.0 0.025 16 Ceiling 2: Raised or Energy Truss 832 38.0 0.0 0.025 21 Wall 1:Wood Frame, 16"D.C. 413 21.0 0.0 0.057 21 Orientation: Front Window 1:Wood Frame:Double Pane with Low-E 50 0.290 14 Orientation: Unspecified Wall 2: Wood Frame, 16"D.C. 722 21.0 0.0 0.057 33 Orientation: Left side Window 2: Wood Frame:Double Pane with Low-E 135 0.290 39 Orientation: Unspecified Wall 3:Wood Frame, 16" D.C. 284 21.0 0.0 0.057 15 Orientation: Back Window 3:Wood Frame:Double Pane with Low-E 29 0.290 8 Orientation: Unspecified Wall 4:Wood Frame, 16"D.C. 252 21.0 0.0 0.057 10 Orientation: Back Window 4:Wood Frame:Double Pane with Low-E 84 0.290 24 Orientation: Unspecified Wall 5:Wood Frame, 16" D.C. 115 21.0 0.0 0.057 4 Orientation: Right side Window 5:Wood Frame:Double Pane with Low-E 29 0.290 8 Orientation: Unspecified Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename: Y:\Barber\Master Suite Addition 2013\Barber.rck Page 1 of 7 Gross Area Cavity Cont. meter Door 1: Glass 18 0.300 5 Orientation: Unspecified Basement Wall 1:Solid Concrete or Masonry 263 15.0 0.0 0.052 14 Orientation: Front Wall height: 8.9' Depth below grade: 7.9' Insulation depth:8.5' Basement Wall 2:Solid Concrete or Masonry 472 15.0 0.0 0.052 25 Orientation:Left side Wall height:8.9' Depth below grade:7.9' Insulation depth:8.5' Basement Wall 3:Solid Concrete or Masonry 175 15.0 0.0 0.052 9 Orientation: Back Wall height:8.9' Depth below grade: 7.9' Insulation depth:8.5' Basement Wall 4:Solid Concrete or Masonry 138 15.0 0.0 0.052 7 Orientation: Right side Wall height: 8.9' Depth below grade: 7.9' Insulation depth:8.5' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed o meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6 nd to co ly wi a ndatory requirements listed in the REScheck Inspection Checklist. j Ethan Peter Hall-Architect Name-Title Signa re Date PETF 6y Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 2 of 7 CREScheck Software Version 4.6.1 J( Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception Is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field VerifiedPre-Inspection/Plan Review Value Value Complies? Comments/Assumptions Re .ID 103.2 Construction drawings and Complies Requirement will be met. PRM documentation sufficiently Does Not U, demonstrates energy code Not Observable Location on plans/spec:A- compliance for the building 2 envelope. Not Applicable 103.2, Construction drawings and Complies Requirement will be met. 403.7 documentation sufficiently Does Not PR31' demonstrates energy code Location on plans/spec:A- compliance for lighting and Not Observable .2 mechanical systems.Systems Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: CompliesI Requirement will be met. PR212 sized per ACOA Manual S based Btu/hr— Btu/hr Does Not on loads per ACOA Manual J or Cooling: Cooling: Not Observable Location on plans/spec:A- other approved methods. Btu/hr— Btu/hr Not Applicable 2 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 3 of 7 2010 New York Foundation Inspection Complies?Comments/Assumptions Energy 303.2.1 Exposed foundation insulation Complies Exception: Requirement is not applicable. FO11]2 protection.Does Not Not Observable Not Applicable 403.8 Snow melt controls. Complies Exception: Requirement is not applicable. FO12]'Does Not U Not Observable Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename: Y:\Barber\Master Suite Addition 2013\Barber.rck Page 4 of 7 Section Plans Verified Field Verified Framing/Rough-In Inspection Re .ID I I Value Value Complies? Comments/Assumptions 402.4.4 Fenestration that is not site built Complies Requirement will be met. FR2011 is listed and labeled as meeting Does Not AAMA/WDMA/CSA 101A.S.2/A440 Not ObservableorhasinfiltrationratesperNFRC Not400thatdonotexceedcode Applicable limits. 402.4.5 IC-rated recessed lighting fixtures Complies Requirement will be met. FR16]' sealed at housingAnterior finish Does Not i and labeled to indicate&It;=2.0 Not Observable Location on plans/spec:A- cfm leakage at 75 Pa 2 Not Applicable 403.2.2 All joints and seams of air ducts, Complies Requirement will be met. FR13]1 air handlers,filter boxes,and Does Not building cavities used as return Not Observable Location on plans/spec: A-ducts are sealed.2 Not Applicable 403.2.3 Building cavities are not used as Complies Requirement will be met. FR15]3 ducts or plenums. Does Not Not Observable Location on plans/spec: A- Not Applicable 2 403.3 HVAC piping conveying fluids R- R-_ Complies Exception: Requirement is FR1712 above 105 QF or chilled fluids Does Not not applicable. below 55 QF are insulated to R-3. Not Observable Not Applicable 403.4 Circulating service hot water R-_ R-_ Complies Requirement will be met. FR18]' pipes are insulated to R-2. Does Not u Not Observable Location on plans/spec:A- NotApplicable 2 403.5 Automatic or gravity dampers are Complies Requirement will be met. FR19]2 installed on all outdoor air Does Not U, intakes and exhausts. Not Observable Location on plans/spec:A- NotApplicable 2 Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename: Y:\Barber\Master Suite Addition 2013\Barber.rck Page 5 of 7 2010New York Insulation Inspection Complies?Comments/Assumptions Ener 303.1 All installed Insulation labeled or Complies Requirement will be met. IN1312 installed R-values provided. Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 6 of 7 Section Plans Verified Field VerifiedFinalInspectionProvisions Re .ID I I Value Value Complies? Comments/Assumptions 402.4.2, Building envelope tightness ACH 50 =_ ACH 50 =_ Complies Requirement will be met. 402.4.2.1 verified by blower door test result Does Not FI17)1 of<7 ACH at 50 Pa.This Not Observable Location on plans/spec:A- V. requirement may instead be met 2 via visual inspection,in which Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm Complies Exception: All ducts and air F[4]1 construction with maximum Does Not handlers are located within d, leakage of 8 cfm to outdoors,or Not Observable conditioned space.12 cfrn across systems. For Not Applicablerough-in tests,verification may pP need to occur during Framing Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats Complies Requirement will be met. Flg]2 installed on forced air furnaces. Does Not Not Observable Location on plans/spec: A- Not Applicable 2 403.1.2 Heat pump thermostat installed Complies Exception: Requirement is FI10)2 on heat pumps.Does Not not applicable. Not Observable Not Applicable 403.4 Circulating service hot water Complies Exception: Requirement is Flll]2 systems have automatic or Does Not not applicable. eaccessible manual controls. Not Observable Not Applicable 401.3 Compliance certificate posted.Complies Requirement will be met. FI7)2 Does Not Not Observable Not Applicable 303.3 Manufacturer manuals for Complies Requirement will be met. FI18]3 mechanical and water heating Does Not equipment have been provided. Not Observable Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 12 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: Addition to Single Family Residence Report date: 05/18/15 Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 7 of 7 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 35.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.29 Door 0.30 Heating &Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments