RC-000165-2015TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development- Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000165-2015
Tax Map No: 252.4-2 RENEWED
Permission is hereby granted to: THOMAS BARBER
For property located at: 8 LOCKHART MOUNTAIN RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tyne of Construction
Owner Name: THOMAS BARBER Single Family-Alteration 167,000.00
Owner Address: 8 Lockhart Mounain RD Total Value 167,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
Residential Addition 2097 s.f.
Garage Addition 544 s.f.
Permit Renewed on Tues.,September 6,2016: Pd$50
50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES:Thursday,June 15,2017
If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of e vion&
f"r
5
SIGNED BY: M'_'
V/ I
the Town of Queensbury.
Director of Building&Code Enforcement
Arm a ON
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000165-2015 lS - 2?e)
Tax Map No: 252.-1-2
Permission is hereby granted to: THOMAS BARBER REVISED
For property located at: 8 LOCKHART MOUNTAIN RD
in the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Address:Single Family-Alteration 167,000.00
Total Value 167,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
THOMAS BARBER
8 Lockhart Mounain RD
Queensbury,NY 12804
Plans&Specifications
PERMIT FEE PAID-TIES PERMIT EXPIRES: Wednesday,June 15,2016
If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Monday,June 15,2015
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
TOWN OF QUEENSBURY
i_Makk
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Flirj
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20150228 Application Number: A20150228
Tax Map No: 523400-252-000-0001-002-000-0000
Permission is hereby granted to: NATALIE AND TOM BARBER
For property located at: 8 LOCKHART Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: NATALIE AND TOM BARBER
tion
8 LOCKHART MOUNTAIN Rd
Residential
AlterationAlte
LAKE GEORGE,NY 12845-0000
Residential 167,000.00
Total Value 167,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2015-228
Residential Additions
2097 s.f. to SFD and 544 s.f. to detached garage
2641 total s.f.
528.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,June 15, 2016
If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T n o eens ryA, ? , •, une 15,2015
14
SIGNED BY I for the Town of Queensbury.
Director of Building&Code Enforcement
PRINCIPAL STRUCTURE APPLICATION Office Use Only
DATE v Y 20/5 Received
v//''
Tax Map ID
TAX MAP ID i/ . '- 2 ° EPer No. 2.015-Z2tia
02 2015 R ee
e FD2. 20
ZONING 111f
Site Plan#
HISTORIC SITE Yes V No
TOWN OF QUEE -
Subdivision#
B JILDING&CO
SUBDIVISION NAME Lot#
TOWN BD.RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWELLINGS,DUPLEXES
OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED &
MODULAR HOMES,BUTNOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE.
APPLICANT 1dM 1534443.1S1' OWNER
ADDRESS 8 ele. .iA " ,%1Z V• ec2 ADDRESS
44 e Vt' I2?1if
98) 36 3e.3k
PHONE/E-MAIL PHONE/E-MAIL
CONTRACTOR 4z:vc.e1 //L h,/S COST OF CONSTRUCTION(ESTIMATED): $ 4 Yi fj
ADDRESS: cub/ L,z4A41,1- 44, Al j2BUILDING ADDRESS: gzz;e,--/Ader
PHONE/E-MAIL
Q/ ,[
CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: v'SH h'+k ode— '" PHONE rf(J—r`05
TYPE OF CONSTRUCTION
Check ail that apply Please indicate measurements as required below
New Addition Alteration 15'floor sq. ft. 2nd floor sq. ft. Total sq.ft. Height
Single Family
Yl
I '377 ' 1Zo ' Si 0411* /!SW
Two-Family
Multi-Family
of units
Townhouse
Business Office
Retail - Mercantile
Factory- Industrial
Attached Garage
of
Other-- asrArre4403 4
60/46e 1
Town of Queensbury Building&Codes Principal Structure Application July 2014
If commercial or industrial indicate name of business L fie'
Proposed use of building or addition j(,
i
Source of heat (circle one) Gas Oil Tropane Solar Other
Fireplace: complete a separate application for Fuel Burning Appliances &
Chimneys
Are there structures not shown on plot plan? t O
Are there easements on the property? 140t44 Nouot3
Site Information
a. Dimensions or acreage of lot 3 ,GPS Ac-42-e4
b. Is this a corner lot? G•A«- `rj
c. Will the grade be changed as a result of construction Yes /No
d. Public water or Private well vitCM
e. Sewer or Private Septic System 21 V/S•Te
Value of all work to be performed (labor or materials)
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed,subject to fees and department
approval.
3. I certify that the application, plans and supporting materials are a true and complete statement/description of
the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building
laws and ordinances, and in conformance with local zoning regulations.
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above: PRINT NAME: R7,44 5 2/i/ C2 DATE tt/L/y,,---
SIGNATURE: DATE Co f2//j
FOR OFFICE USE ONLY
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
2
Town of Queensbury Building&Codes Principal Structure Application July 2014
V / N2AN /AResidential Plan Review: One & Two Family Dwellings
Two (2) full sets of plans
Over 1,500 sq. ft. requires engineering stamp
Design loads on plans: 90 Wind Floor Loads 40 psf
north of Rt. 149 - 60)] 50 Ground Snow Load Sleeping Areas & Attics 30 psf
Calculations
Window schedule with glass size
Door schedule / Main entrance 36" door
Emergency Escape or Bedrooms and Habitable Space
iAbove / Below grade: 5.7 sq. ft.
Grade: 5.0 sq. ft.
24" (h) x 20" (w) minimum
44" maximum height above door
Residential: Check paperwork compliance and Inspection checklist -Okay
Driveway length: 300' or more -12' width required / 500' or more -turnaround required
Foundation insulation to basement floor
v
Damp proofing / Waterproofing materials on plans
tiAundation drainage on plans, if required
6" drop in 10' Exterior grade
Framing cross section for each roof line, Vertical fire stopping every 10' where required
ce & Snow Shield -24" inside exterior wall / 24" inside knee walls SEE c ter— Li1.
Platforms at exterior doors p %:,6z)
Stairway headroom 6'8"; all stairs 36" width
Stair Run and Rise
1,.. 4\ Winder Run and Rise
piral not allowed from 2nd
story
oke Detectors -battery backup and proper location interconnected
Bathroom fixtures -proper clearance
Hall width -36" width
jt
Handrails more than four risers on open sides
Railing & Guards + 30" / Basement stairs included / Closed risers more than 4" in height
rSafety glazing notes for required areas
t3 Garage fire separation
Garage floor sloped
Attic access o3 E _‘") m p `_ 3
Roof over 30" -22" x 30" / Crawl spaces 18" x 24" access
arbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15'
f sleeping area
Soil Test results, if required
Septic to well or water line separation
All paperwork signed
Note on plans energy saving light bulbs
Blower door test agency paperwork
0 j floodplain Permit Required -Check Map
p,s_
Truss ID Signage I O C 71- ELj G 1 1=
Residential Plan Review -1 & 2 Family Dwellings 1-5-2015
CHECKLIST-SINGLE FAMILY PROJECT
11
Project name: 3Pe.ft '-r-4 geStOta.let iii C p
REQUIRED-2 sets of the following documentation Yes No N/A
1. Building permit application completed
1
2. Energy Code inspector's report from REScheck
3. Septic alteration (if applicable)
4. Solid Fuel Burning or Gas Appliance form (if applicable)
5. Driveway Permit
6. Structural Drawings j
a. Floor plans
b. Foundation plan
c. Cross Sections
d. Elevations
e. Window & Door Schedule
f. Natural Light, Ventilation and Emergency Egress
g. Plans signed/sealed by registered architect or engineer
7. Plot plans: indicate proposed structure, showing setback dimension from all surveyed
property lines
a. Show location of all existing structures on property
b. Show location of water supply (well or water lines)
c. Show location and configuration of septic disposal system or sewer line
8. Electrical inspection agency selected j
CHECKLIST- MULTIPLE DWELLING/COMMERCIAL
Project Name:
REQUIRED-2 sets of the following documentation Yes No , N/A
1. Building permit application completed
2. Energy Code COMcheck and inspector's report form
3. Septic alteration (if applicable)
4. Solid Fuel Burning or Gas Appliance form (if applicable)
5. Driveway Permit
6. Structural Drawings
a) Floor plans
b) Foundation plan
c) Cross Sections
d) Elevations
e) Design loads including floor, snow load and wind load
f) Seismic design
g) Plans signed and sealed by registered architect or engineer
h) Window& Door Schedule
7. Plot plan—indicate proposed structure, showing setback dimension from all surveyed
property lines
a) Show location of ail existing structures on property
b) Show location of water supply(well or water lines)
c) Show location and configuration of septic disposal system or sewer fine
8. Electrical inspection agency selected
4
Town of Queensbury Building&Codes Principal Structure Application July 2014
Office Use Only
FUEL BURNING APPLICANCE &
CHIMNEY
APPLICATIONReceived
ax Map ID
4 7 X11
met No. Lti I S
DATE ermit Fee
TAX MAP ID 262. — / I;1 3 t it 0 2 2015
TOWN OF QUEENSBURY
ZONING 5A DING&CODES
OWNER: 727 j PHONE/E-MAIL 5 -&g--ao2.
ADDRESS ea
4 F /4 Al /2641,
INSTALLER/BUILDER. r-/,e`t /t s.6 Lrv 2A5 £41if PHONE/E-MAIL 6) J 3c7 -3c.. 3P
ADDRESS: Lo,, hn2.f /i14, E J, ; CT /Lf-i , /v` ` /2 Yom,) *1'6-J°Udvc-7
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: )Ve4154'4t PHONE 6 1 (1-
fieWBUILDINGADDRESS: 86 Mi / /r•
t
14t0 6• 0 NYY afW,a
Fuel Burning Appliance Information Wood Coal Pellet Gas Oil NOTE: ROUGH-IN & FINAL
Stove INSPECTIONS ARE REQUIRED.
Fireplace Insert
Fireplace, Factory built'
Fireplace, Masonry
Furnace (Garage Only)
If Factory built provide manufacturer name: 0164 fZSnite- ; model#: 3716-
Listed
X 6-
Listed by:Number:
Chimney Information
Masonry** (check one) Block Brick Stone
Flue Tie Steel Size in inches
Material Double wall Triple wall Insulated VDirect Vent Chimney Liner
If Non-masonry provide manufacturer name: model#:
DECLARATION: Construction/installation must conform to NYS Fire Prevention& Building Code and I or manufacturer
requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all
conditions that are part of these requirements and also will allow inspector's to enter premises to perform required
inspections.
I have read and agree to the above: Print Name: Date: 1/2/1,
SignatureDate: 0-bj
5
Town of Queensbury Building&Codes Principal Structure Application July 2014
REScheck Software Version 4.6.1
Compliance Certificate
Project Addition to Single Family Residence
Energy Code: 2010 New York Energy Conservation
2015
Location: Warren County, New York
Construction Type: Single-family IiE_ENSSURY
Project Type: Addition
Orientation: Bldg. faces 135 deg. from North
Climate Zone: 6 (7635 HDD)
Permit Date:
FILECOPY
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
8 Lockhart Mountain Road Tom&Natalie Barber Ethan Peter Hall
Queensbury,NY 12804 8 Lockhart Mountain Road Rucinski Hall Architecture
Lake George,NY 12845 627 Maple Ave
Saratoga Springs, NY 12866
518-580-1905
ephall@nycap.rr.com
Compliance:
Compliance: 7.5%Befter Than Code Maximum UA: 295 Your UA: 273
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-of rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Assembly or Cavity Cont.
U-Factor UA
Ceiling 1: Raised or Energy Truss 658 38.0 0.0 0.025 16
Ceiling 2: Raised or Energy Truss 832 38.0 0.0 0.025 21
Wall 1:Wood Frame, 16"D.C. 413 21.0 0.0 0.057 21
Orientation: Front
Window 1:Wood Frame:Double Pane with Low-E 50 0.290 14
Orientation: Unspecified
Wall 2: Wood Frame, 16"D.C. 722 21.0 0.0 0.057 33
Orientation: Left side
Window 2: Wood Frame:Double Pane with Low-E 135 0.290 39
Orientation: Unspecified
Wall 3:Wood Frame, 16" D.C. 284 21.0 0.0 0.057 15
Orientation: Back
Window 3:Wood Frame:Double Pane with Low-E 29 0.290 8
Orientation: Unspecified
Wall 4:Wood Frame, 16"D.C. 252 21.0 0.0 0.057 10
Orientation: Back
Window 4:Wood Frame:Double Pane with Low-E 84 0.290 24
Orientation: Unspecified
Wall 5:Wood Frame, 16" D.C. 115 21.0 0.0 0.057 4
Orientation: Right side
Window 5:Wood Frame:Double Pane with Low-E 29 0.290 8
Orientation: Unspecified
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename: Y:\Barber\Master Suite Addition 2013\Barber.rck Page 1 of 7
Gross Area
Cavity Cont.
meter
Door 1: Glass 18 0.300 5
Orientation: Unspecified
Basement Wall 1:Solid Concrete or Masonry 263 15.0 0.0 0.052 14
Orientation: Front
Wall height: 8.9'
Depth below grade: 7.9'
Insulation depth:8.5'
Basement Wall 2:Solid Concrete or Masonry 472 15.0 0.0 0.052 25
Orientation:Left side
Wall height:8.9'
Depth below grade:7.9'
Insulation depth:8.5'
Basement Wall 3:Solid Concrete or Masonry 175 15.0 0.0 0.052 9
Orientation: Back
Wall height:8.9'
Depth below grade: 7.9'
Insulation depth:8.5'
Basement Wall 4:Solid Concrete or Masonry 138 15.0 0.0 0.052 7
Orientation: Right side
Wall height: 8.9'
Depth below grade: 7.9'
Insulation depth:8.5'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed o meet the 2010 New York Energy
Conservation Construction Code requirements in REScheck Version 4.6 nd to co ly wi a ndatory requirements listed in
the REScheck Inspection Checklist.
j
Ethan Peter Hall-Architect
Name-Title Signa re Date
PETF
6y
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 2 of 7
CREScheck Software Version 4.6.1
J( Inspection Checklist
Energy Code: 2010 New York Energy Conservation Construction Code
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
Is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section
Plans Verified Field VerifiedPre-Inspection/Plan Review Value Value
Complies? Comments/Assumptions
Re .ID
103.2 Construction drawings and Complies Requirement will be met.
PRM documentation sufficiently Does Not
U, demonstrates energy code Not Observable Location on plans/spec:A-
compliance for the building 2
envelope. Not Applicable
103.2, Construction drawings and Complies Requirement will be met.
403.7 documentation sufficiently Does Not
PR31' demonstrates energy code Location on plans/spec:A-
compliance for lighting and Not Observable .2
mechanical systems.Systems Not Applicable
serving multiple dwelling units
must demonstrate compliance
with the commercial code.
403.6 Heating and cooling equipment is Heating: Heating: CompliesI Requirement will be met.
PR212 sized per ACOA Manual S based Btu/hr— Btu/hr Does Not
on loads per ACOA Manual J or Cooling: Cooling: Not Observable Location on plans/spec:A-
other approved methods. Btu/hr— Btu/hr Not Applicable 2
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3)
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 3 of 7
2010 New
York Foundation Inspection Complies?Comments/Assumptions
Energy
303.2.1 Exposed foundation insulation Complies Exception: Requirement is not applicable.
FO11]2 protection.Does Not
Not Observable
Not Applicable
403.8 Snow melt controls. Complies Exception: Requirement is not applicable.
FO12]'Does Not
U Not Observable
Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename: Y:\Barber\Master Suite Addition 2013\Barber.rck Page 4 of 7
Section
Plans Verified Field Verified
Framing/Rough-In Inspection
Re .ID I I Value Value Complies? Comments/Assumptions
402.4.4 Fenestration that is not site built Complies Requirement will be met.
FR2011 is listed and labeled as meeting Does Not
AAMA/WDMA/CSA 101A.S.2/A440
Not ObservableorhasinfiltrationratesperNFRC
Not400thatdonotexceedcode Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures Complies Requirement will be met.
FR16]' sealed at housingAnterior finish Does Not
i
and labeled to indicate&It;=2.0 Not Observable Location on plans/spec:A-
cfm leakage at 75 Pa 2
Not Applicable
403.2.2 All joints and seams of air ducts, Complies Requirement will be met.
FR13]1 air handlers,filter boxes,and Does Not
building cavities used as return Not Observable Location on plans/spec: A-ducts are sealed.2
Not Applicable
403.2.3 Building cavities are not used as Complies Requirement will be met.
FR15]3 ducts or plenums. Does Not
Not Observable Location on plans/spec: A-
Not Applicable 2
403.3 HVAC piping conveying fluids R- R-_ Complies Exception: Requirement is
FR1712 above 105 QF or chilled fluids Does Not not applicable.
below 55 QF are insulated to R-3.
Not Observable
Not Applicable
403.4 Circulating service hot water R-_ R-_ Complies Requirement will be met.
FR18]' pipes are insulated to R-2. Does Not
u Not Observable Location on plans/spec:A-
NotApplicable 2
403.5 Automatic or gravity dampers are Complies Requirement will be met.
FR19]2 installed on all outdoor air Does Not
U, intakes and exhausts. Not Observable Location on plans/spec:A-
NotApplicable 2
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename: Y:\Barber\Master Suite Addition 2013\Barber.rck Page 5 of 7
2010New
York Insulation Inspection Complies?Comments/Assumptions
Ener
303.1 All installed Insulation labeled or Complies Requirement will be met.
IN1312 installed R-values provided. Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 6 of 7
Section
Plans Verified Field VerifiedFinalInspectionProvisions
Re .ID I I Value Value
Complies? Comments/Assumptions
402.4.2, Building envelope tightness ACH 50 =_ ACH 50 =_ Complies Requirement will be met.
402.4.2.1 verified by blower door test result Does Not
FI17)1 of<7 ACH at 50 Pa.This Not Observable Location on plans/spec:A-
V. requirement may instead be met 2
via visual inspection,in which Not Applicable
case verification may need to
occur during Insulation
Inspection.
403.2.2 Duct tightness via post- cfm cfm Complies Exception: All ducts and air
F[4]1
construction with maximum Does Not handlers are located within
d,
leakage of 8 cfm to outdoors,or Not Observable conditioned space.12 cfrn across systems. For
Not Applicablerough-in tests,verification may pP
need to occur during Framing
Inspection,with maximum
leakage of 6 cfm across systems
and 4 cfm without air handler.
403.1.1 Programmable thermostats Complies Requirement will be met.
Flg]2 installed on forced air furnaces. Does Not
Not Observable Location on plans/spec: A-
Not Applicable 2
403.1.2 Heat pump thermostat installed Complies Exception: Requirement is
FI10)2 on heat pumps.Does Not not applicable.
Not Observable
Not Applicable
403.4 Circulating service hot water Complies Exception: Requirement is
Flll]2 systems have automatic or Does Not not applicable.
eaccessible manual controls.
Not Observable
Not Applicable
401.3 Compliance certificate posted.Complies Requirement will be met.
FI7)2
Does Not
Not Observable
Not Applicable
303.3 Manufacturer manuals for Complies Requirement will be met.
FI18]3 mechanical and water heating Does Not
equipment have been provided.
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 IHigh Impact(Tier 1) 12 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3)
Project Title: Addition to Single Family Residence Report date: 05/18/15
Data filename:Y:\Barber\Master Suite Addition 2013\Barber.rck Page 7 of 7
2010 New York
Energy Conservation
Construction Code
Energy Efficiency
Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 35.00
Ductwork (unconditioned spaces):
Door Rating U-Factor SHGC
Window 0.29
Door 0.30
Heating &Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments