Loading...
RC-000244-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000244-2016 Date Issued: Friday, December 1, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000244-2016 has been completed. Tax Map Number: 296.15-1-2 Location: 10 GENTRY HILL NORTH Owner: Schermerhorn Residential Holdings L.P. Applicant: Schermerhorn Residential Holdings L.P. This structure may be occupied as a: Cottage Hill Project, Bldg.#20 6-units 9174 s.£,garage 1446 s.£,FPs By Order of Town Board see SP 59-2012 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY .41114111Plkbak742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150110 Application Number: A20150110 Tax Map No: 523400-296-015-0001-002-000-0000 Permission is hereby granted to: SCH COTTAGE HILL. LLC For property located at: Gentry Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SCH COTTAGE HILL, LLC Fireplace 536 BAY Rd Suite 2 Garage Attached QUEENSBURY NY 12804-0000 Townhouse $140,000.00 Total Value $140,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2015-110 Cottage Hill Project bldg. #20 10 Gentry Hill North TOWNHOUSE 6-unit see SP 59-2012 $1,834.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, May 08, 2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To Queen ry; � i u ay 08,2015 SIGNED BY 41 •,\ for the Town of Queensbury. Director of Building&Code Enforcement (.D FILE COPY --- -„e.,....- -----3`'010 OFFICE USE ONLY TAX MAP NO. 291(c • k) -kr -Z PERMIT NO. 20 - 110 FEES: PERMIT RECREATION ENGINEERING (if applicable` PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: -OWNER: 6,4114 ADDRESS: SSG, 61 kici+vie 2 ADDRESS: a u'-f -1 1 PHONE NOS. lia,.'' j- 4 - PHONE NOS. e� CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 1/4A�� �i PPHHOONE: _2_ ____ LOCATION OF PROPERTY: tLOL 62 2.0L/ OW * � Mee IMI HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? )SCI YES ❑ NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: I I PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z0 o F- APPLY TO YOUR Z 1=- ct p u) Co �` w PROJECT p I t O i_ 0 _ _ W J d Z C� �- z z < I < 1; Li N � 0u - u Q_ _ c6 SINGLE FAMILY 1 TWO-FAMILY ,j.� MULTI-FAMILY //�� ./ A(,,(� M %I {�,19 (NO.of UNITS (0 ) `� I IWI �Ih 1 ' J 14 `�' 1 TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE I FY R I INDUSTRIAL ATTACHED f I / / (841 I 444 GARAGE(1,2,3) lye, OTHER Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: CtirThee tAllA0 1VU0M' ESTIMATED CONSTRUCTION COST:6 I40,0CP _ FUEL TYPE: Ofris. th4.5 HEAT TYPE: I12.. *HOW MANY FIREPLACES): 4p AND I OR WOODSTOVES(S): _Ak ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? 140 PROPOSED USE OF BUILDING OR ADDITION: "`0141 r ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? 4) 4 • se plea= - _ I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree t. h,, above. !r /j �,; � Signed iv&Ap zr- Di ector of Building & Codes: 76i-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator. 761-8218 (for questions regarding required permits, the permit process; application requirements or to schedule an appointment) Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 ..«>e e�>,.»r..,�.. >..a ,.kms>r>».«» »� ..,f>s,._ _.�� > , a , Permission is hereby granted to the above r This application I proposed action described ; Applicant to erect or alter the building ; herein is found to be in accordance with the described herein in accordance with said ; zoning Laws of the Town of Queensbury. Application: . ; d ! ' d : Ati/aidi ; L } s 12r c & CODES A"''i" AL ZONING APPROVAL d n, . 1 6 'ATE DATE , 3 , } '' QUESTIONS? CALL 761-8256 OR EMAIL------ , Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION I Operating Permit Issued: Yes Na wrr 'e#ue rnsasq'r9et /f Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office* 742 Bay Road, Queensbury NY 12804 Office Use Only Town of Queensbury Building & Codes Received: Tax Map ID: FUEL BURNING APPLIANCE & CHIMNEY APPLICATION Permit No.: Permit Fee: $ Application is hereby made to the Building & Codes Office for the issuance of a Building & Use Permit pursuant to the NYS Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws,ordinances,regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. Important Note To Applicant: Rouqh-ln and Final Inspections Are Required: Date4011•....7.19/15 Owner Thi' installer/Builder Address `{ Rao Address dam► { 41:%4: Phone /tPhone Location of proposed construction and/or installation: et.teaa. AUL — 3' 6,U a Contact Person for Building&Codes Compliance: > 03 d'Ara 1411310$" afrt Subdivision Name: ,e—AFP 41/ Fuel Burning Appliance Information Wood Coal Pellet Gas Oil Stove Fireplace Insert V Fireplace,factory built*— Fireplace,Masonry 1 Furnace,(Garage Only) *If Factory Built, Please Provide: Manufacturer Name: CcUMMelleg Model No. aki-sap Listed By: Number. Chimney Information Masonry** ✓check one _Block __Brick Stone Flue ✓check one Tile f` Steel Size in Inches Material ✓check one _Double Wall _Triple Wall _Insulated V6irect Vent _Chimney Liner *' If Non-Masonry,please provide: Manufacturer Name: Model No. Signatures: Print Name: ,:` -77 4441— Signature: '-`/1 Date: 21 , l�2_t/5 ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. 6!6`"__. emu.- Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 12/01/2017 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: OCC-Inspections Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Primary Owner [Schermerhorn Residential Holdings L.P.] Contractor [Schermerhom Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhom Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal YES Chris Exit Access FC1014&FC1029 YES Exit Enclosure FC1020&FC1029 YES Exit Discharge FC1024&FC1029 YES Truss ID Signage FC505.3 YES Ok Electrical Wiring Enclosed/Labeled FC605.3.1 YES Combustibles in Equipment Rooms FC 315.2.3 YES F.D.Signage-FC510 YES Interior Finishes FC803-804 YES Smoke Detectors FC907 YES Ok CO Detectors FC610 YES Verified Clearance to Sprinkler/Ceiling FC315.2.1 18"/24" YES Sprinkler System Annual YES RECIEVED NFPA 13 LETTER FROM FIRETEK DATED 11/30/2017 Sprinkler FDC YES Knox Box:installed/checked FC506 YES Verified Occupancy Cycle YES R Stillman,Gary(Inspector) Dec 01,2017 Page(2) sFRE\T'EK nT ,,, , 1 SPRINKLER SYSTEMS, LLC -I 58 Hudson River Rd. • Waterford, NY 12188 Phone: (518)244-3772 Fax: (518)238-2608 11/30/17 Mr. Mike Palmer Fire Marshall Town of Queensbury 742 Bay Rd. Queensbury,NY 12804 RE: Cottage Hill Apts. 10 Gentry Hill North Queensbury,NY Mike, The installation of the fire sprinkler system, at the above address, has been completed. The system is on and operational. To the best of my knowledge the installation conforms to NFPA 13R. Should you require anything further, please give me a call. Sincerely, fri7;Jj Bob Wood Vice President Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 12/01/2017 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Primary Owner [Schermerhom Residential Holdings L.P.] Contractor iteA--(/Granted Permission [Schermerhom Residential Holdings L.P.] [Schermerhorn Residential Holdings L.P.] Applicant �yi [Schermerhom Residential Holdings L.P.] Checklist Item �J� Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN UNIT A-SERIAL#A17F285024 UNIT B-SERIAL#A17F285009 UNIT C-SERIAL#A17F285008 UNIT D-SERIAL#Al 7F285016 UNIT E-SERIAL3 Al 7F285026 UNIT F-SERIAL#Al 7F285019 Building Inspector Notes YES Final for Units A-F Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel height above fp opening YES Return to verify-see page 15 of installation manual for mantle clearances 12/1/17 ok Witness Operation YES Return to verify 12/1/17 ok Page(1) Dec 01,2017 . INSPECTION WORKSHEET(FMGAS-007236-2017) Checklist Item Passed Comments CO Detection YES Return to verify 12/1/17 ok CSST Bonding YES Stillman,Gary(Inspector) Dec 01,2017 Page(2) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 09/21/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor [Schermerhorn Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Primary Owner [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhorn Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN SERIAL#A17F285024 Building Inspection notes YES UNIT A Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Hearth extension not required for installation manual Page 14 Mantel-height above fp opening NO Return to verify-see page 15 of installation manual for clearances Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding NO Return to verify Stillman,Gary(Inspector) Sep 21,2017 Page(1) j INSPECTION WORKSHEET (FMGAS-005673-2017) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 09/21/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor [Schermerhorn Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Primary Owner [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhorn Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN SERIAL#A17F285009 Building Inspection notes YES Unit B Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening NO Return to verify-see page 15 of installation manual for mantle clearances Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding NO Return to verify Stillman,Gary(Inspector) - Sep 21,2017 �-, - .�� Page Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 09/21/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor [Schermerhorn Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Primary Owner [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhorn Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN SERIAL#A17F285008 Building Inspection notes YES Unit C Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening NO Return to verify-see page 15 of installation manual for clarification Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding NO Return to verify Stillman,Gary(Inspector) Sep 21,2017 Page(1) INSPECTION WORKSHEET (FMGAS-005677-2017) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 09/21/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor [Schermerhorn Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Primary Owner [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhorn Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN SERIAL#A17F285016 Building Inspection notes YES Unit D Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening NO Return to verify-referred to page 15 of installation manual for clearances Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding NO Return to verify Stillman,Gary(Inspector) Sep 21,2017 Page(1) • Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 09/21/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor [Schermerhorn Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Primary Owner [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhorn Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN SERIAL#A17F285026 Building Inspection notes YES Unit E Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Vertical Chase YES Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 installation manual Mantel-height above fp opening NO Return to verify-see page 15 of installation manual for clearances Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding NO Return to verify Stillman,Gary(Inspector) Sep 21,2017 Page(1) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: RC-000244-2016 Case Module: Permit Inspection Date: 09/21/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 10 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor [Schermerhorn Residential Holdings L.P.] Granted Permission [Schermerhorn Residential Holdings L.P.] Primary Owner [Schermerhorn Residential Holdings L.P.] Applicant [Schermerhorn Residential Holdings L.P.] Checklist Item Passed Comments Fire Marshal Notes YES Superior fireplace-model#DRT2033TMN SERIAL#A17F285019 Building Inspection notes YES Unit F Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3"top 1"sides-exceeds Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Hearth extension not required per page 14 of installation manual Mantel-height above fp opening NO Return to verify-see page 15 installation manual for clearances Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding NO Return to verify Stillman,Gary(Inspector) Sep 21,2017 Page(1) Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 r• Table 7:Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside corner Outside Corner Recessed Location • See Table8 „,,,,, / Ni P�� ,,,, _G r- .F C Fixed B---0 I Z wall % lose. ❑� .Operable Fixed Balcony with No side Wall Balcony w Perpendicular Side Wall Openable I Closed _ „�:, Q e p_D � B a l 44 —B— A M `111 r, M I M r_ EV TERMINATION CAP O AIR SUPPLY INLET Di GAS METER 0 RESTRICTED AREA (TERMINATION PROHIBITED) U.S.Installation** Canadian Installation' A Clearance above grade,veranda,porch,desk,or balcony 12"(300 mm)** 12"(300 mm)* 8 Clearance to window or door that may be opened 6"(150 mm) 6"(150 mm) for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW),and<50,000 Btu/h for fireplaces>10,000 Btu/h(3 kW) (15 kW), 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** C Clearance to permanently closed window 9"(229 mm) 12"(305 mm) recommended to prevent window condensation recommended to prevent window condensation 0 Vertical clearance to ventilated soffit located above the 18"(458 mm) 18"(458 mm) termination within a horizontal distance of 18"(458 mm) E Clearance to unventilated soffit 12"(305 mm) 12"(305 mm) F Clearance to outside corner 5"(127 mm) 5"(127 mm) minimum minimum G Clearance to inside corner 6"(152 mm)minimum 6"(152 mm)minimum H Clearance to each inside of center line extended above 36"(910 mm) 36"(910 mm) meter/regulator assembly within a height of 15 ft above the meter/regulator assembly** within a height of 15 ft above the meter/ regulator assembly* I Clearance to service regulator vent outlet 36"(910 mm)** 36"(910 mm)* J Clearance to nonmechanical air supply inlet to building or 6"(150 mm) 6"(150 mm) the combustion air inlet to any other fireplace for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW)and<50,000 Btu/h(15 kW), for fireplaces>10,000 Btu/h(3 kW) 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** K Clearance to a mechanical air supply inlet 36"(910 mm)above if within 10 ft(3 m)horizontally** 72"(1830 mm)* L Clearance above paved sidewalk or paved diveway located 84"(2130 mm)$ 84"(2130 mm)$ on public property M Clearance under veranda,porch,deck or balcony 12"(300 mm)*# 12"(300 mm)*$ N Depth of alcove(maximum) 72"(1830 mm)** 72"(1830 mm) 0 Clearance to termination(alcove) 6"(15.2 mm)** 6"(15.2 mm)* P Width of alcove(minimum) 36"(910 mm)** 36"(910 mm)* G Clearance to combustible above(alcove) 18"(457 mm)** 18"(457 mm)* * In accordance with the current CSA-B149.1 National Gas And Propane Installation Code ** In accordance with the curent ANSI Z223.1/NFPA 54 National Fuel Gas Codes # A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings *# Only permitted if veranda,porch,deck,or balcony is fully-open on a minimum two sides beneath the floor 13 Innovative Hearth Products Installation Superior"'DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 M MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8),with the following exception:The unit may not be recessed (allowance made for mantel legs/side trim in Figure 6).When the unit is installed with one side flush with a wall,the wall on the other side of the unit must not extend beyond the front edge of the unit(Figure 6). Table 8:Minimum Clearances * 1"(26mm)to wrapper for 45"model,all Back others 1/2"(13mm)to wrapper 0"(0 mm)to Spacers Sides 1/2"(13 mm)to wrapper 0"(0 mm)to Spacers** Top Standoffs 0"(0 mm)to top standoffs Floor 0"(0 mm) From Bottom of Unit to Ceiling 64"(1626 mm) Vent 3"(76 mm)—Top**** 1"(25.4 mm)—Sides and Bottom Front Service Clearance— 38"(914 mm) clearance immediately in front of viewing area(s) *3"(76 mm)above any horizontal/inclined vent component. **See Page 19 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. ***Top vent clearance can be reduced to 2"on horizontal runs when first elbow is located at least 6 ft above the fireplace. The fireplace must be mounted on a fully supported base extending the full width and depth of the unit.The fireplace may be located on or near conventional construction materials. However, if installed on combustible materials,such as carpeting,vinyl tile or other combustible material other than wood flooring,the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Hearth Extension A hearth extension is not required with this fireplace. If a hearth extension is used, do not block the lower control compartment door.Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements. Shelf Height To provide for the lowest possible shelf surface, use the rear vent model. For top vent models,the venting attached to the top vent should be routed in a way to minimize obstructions to the space above the fireplace. Do not insulate the space between the fireplace and the area above it(Table 9 and Table 10).The minimum height from the base of the fireplace to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Table 9 and Table 10. Table 9:Combustible Shelf Height—Top Vent Top Vent with one 90°Elbow Model Secure Vent® Secure Flex®(flex elbow) DRC2033/DRT2033 44"(1118 mm) 46"(1168 mm) mom! DRC2035/DRT2035 47"(1194 mm) 49"(1245 mm) ' imm (1321 DRC2040/DRT2040 52" 54" No combustibles mm) (1372 mm) or insulation Shelf Height in the shaded DRC2045/DRT2045 50"(1270 mm) 52"(1321 mm) (see table) area between the appliance and the shelf above it. 14 Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 Table 10:Combustible Shelf Height—Rear Vent Rear Vent with two 90°Elbows Model >_3"clearance from shelf to Secure Vent® Secure Flex®(flex elbow) top of fireplace and/or vent DRC2033/DRT2033 34"(864 mm) 34"(864 mm) pipe,whichever is higher w DRC2035/DRT2035 351/2"(902 mm) 351/2"(902 mm) j� im1 DRC2040/DRT2040 401/2"(1029 mm) 401/2"(1029 mm) 1 ' 1 combustibles Shelf Height , or insulation DRC2045/DRT2045 451/2"(1156 mm) 451/2"(1156 mm) (see table) p in the shaded area between theand the applian shelfce above it. Figure 6:Combustible Side Clearances Figure 7:Mantel Height At 6"minimum side wall clearance,a H--Mantel depth combustible Top View of wall can project 18 Fireplace (457) ,�--' to any length. 16(406) t 45° Combustible materials 14(356) 3 1/2" allowed in shaded area 1'_ (89 mm) "Safe Zone". 12(305) , Combustible walls 10(254) shown in dark gray Combustible mantel 8(203) legs may project 12 8 4 Hood r ___ = beyond either side of (3051 + (203) —(1c2) a— the fireplace opening 1p g 2 _ - ; __= as long as they are kept within the shaded area in.(mm) (254) (152) (51) ^ L fA- illustrated here. Fireplace 6" (152 mm) Wall Finishes/Surrounds/Mantels NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the fireplace front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the fireplace face(Figure 41). Non-combustible materials,such as surrounds and other fireplace trim,may be installed on the fireplace face,but they must not cover any portion of the removable glass panel or control compartment. Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do not allow anything to hang below the fireplace hood. Minimum clearance requirements include any projections such as shelves,window sills, mantels,etc.above the fireplace. NOTE:To avoid heat-related finish damage,use finish materials rated 175°F,or higher,on the underside of the mantel. INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace, follow these steps: 1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction). 2. Remove the shipping pad, exposing the front glass door. 3. Remove the glass door(Page 57). NOTE: Place the glass door on the shipping carton to protect its surface. 15 RA Foundation Inspection Report Office No. (518) 761-8256 Date Ins ection que l -Fe. •d: b ' Ols Queensbury Building&Code Enforcement Arrive: �'� - i epart: 7= ar ".� 742 Bay Rd.,Queensbury,NY 12804 Inspector's Init' 'L_ NAME: Y YYU2,✓ P• ' IT#: 20 k cj- 11 O LOCATION: C.Ar, 11c '2Z, ID 6gAiltill nb,✓'rh INSPECT ON: to i 216 2LlS TYPE OF STRUCTURE: I Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. L •Foundation/WallpourY/ //�� (0 Reinforcement in Place v Footing Dowels or Keyway in place \?‘ Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 141Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re lip?d: I3Ir)Queensbury Building&Code Enforcement Arrive: .Z.._ aDepart: - pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia 1 NAME: r fMIT#: • ES I I O LOCATION: k) _ /ALA ► INSPECT ON: TYPE OF STRUCTURE: ice, • 'O.. I i Ll— Comments �� Y N N/A Footings Piers Monolithic Slab '( Z-3)) Reinforcement in Place The contractor is responsible for providing protection from freezing ?leak k6 for 48 hours following the placement of the concrete. C —t� l (!�(-� purpose • r this on site. � j/� , Foundation/Wallpour Reinforcement in Place � /`/1'`'17-&)615. Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 la Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re•uest - eived: 2 1P11 `.3 Queensbury Building&Code Enforcement Arrive: a Or. Depart: _ 11r 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: Al NAME: ,r ' RMIT#: 15 I IP LOCATION: &t rnk )01 , -O INSPECT ON: to t laa.12-CAS TYPE OF STRUCTURE: Comments Y / N N/Ak) 11 b 22 � Footings Piers VVV Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 c-- NEBPA BLOWER DOOR FORM Home Energy Experts ' North East Building Performance Adt isors 518..4.10.19141 Contractor: Schermerhorn Construction Date: 11/30/17 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Phone#2 Location tested: Building 10,Gentry Hill North Unit A City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume 8 x (432) +9 x (796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60= 61.95 cfm 1.5= 16.8 2= 15.4 Minimum CFM50 =Airflow x N Factor 61.95 cfm x 15.4 = 954 CFM50 2. = 4 What#should be 3= 13.7 Blower Door Diagnostics Ring Open o� A Inside Temp: 10F Baseline Pressure Pa. B Outside Tem p: F Fan Pressure : Pa. C [Flow @ CFM50= \ \ W NOTES: The safe zone for this home is+/- 30%of the minimum CFM50 High side = 1240 @CFM 50 Low side= 667 @CFM 50 CFM50 Q 50 x 60 minutes = ( %O Volume of building x N factor 16354{8 ACH= ` L New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. As a reference,Energy Star homes must come in at.35 ACH naturally to qualify. Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI GoldStar" Warrensburg, NY 12885 C O N T R A C T O R I D: 1006099 NEBPA BLOWER DOOR FORM Home Energy Experts I Norah Essr Building Performsace Adrisors 3!8.350.494] Contractor: Schermerhorn Construction Date: 11/30/17 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Phone#2 Location tested: Building 10,Gentry Hill North Unit B City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume 8 x(432) +9 x (796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60= 61.95 cfm 1.5= 16.8 2= 15.4 Minimum CFM50 =Airflow x N Factor 61.95 cfm x 15.4 = 954 CFM50 -2'19-= .4 What#should be 3=13.7 Blower Door Diagnostics Ring Open Inside Temp: ( 0 F Baseline Pressure — �qDPa. B Outside Temp:�F Fan Pressure 3d Z Pa. C Flow & CFM50= D NOTES: The safe zone for this home is+/- 30%of the minimum CFM50 High side = 1240 @CFM 50 Low side = 667 @CFM 50 /- CFM(a,50 x 60 minutes = (0 d o Volume of building x N factor 163548 ACH= New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. (As a reference.Ener,-v Star homes must come in at.35 ACH naturally to qualify. Blower Door testing performed by North East Building Performance Advisors l r 7 Rocky Ridge BPI GoldStar" Warrensburg, NY 12885 C O N T R A C T O R I D: 1006099 NEBPA BLOWER DOOR FORM Home Energy Experts North East Building Performance Adi isors 5l8.350.f9F1 Contractor: Schermerhorn Construction Date: 11/30/17 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Phone#2 Location tested: Building 10,Gentry Hill North Unit C City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume 8 x (432) +9 x (796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60= 61.95 cfm 1.5=16.8 '2= 15.4 Minimum CFM50 = Airflow x N Factor 61.95 cfm x 15.4 = 954 CFM50 2. = 4 What#should be 3= 13.7 Blower Door Diagnostics Ring Open —010 Inside Temp: �Z F Baseline Pressure J • � Pa. B Outside Temp: 30 F Fan Pressure – 3 �7 Pa. C Flow @ CFM50= J NOTES: The safe zone for this home is+/-30%of the minimum CFM50 High side = 1240 @CFM 50 Low side= 667 @CFM 50 CFM e,50 x 60 minutes = I b 00 Volume of building x N factor 163548 ACH= • LA Z New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. (As a reference.Energy Star homes must come in at.35 ACH naturally to qualify. Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI GOIdStar- Warrensburg, NY 12885 C O N T R A C T O R 11113: 1006099 NEBPA BLOWER DOOR FORM Home Energy Experts iVoith Eau Bui/ding Pe4formonce Adi.isots 518.350.99141 Contractor: Schermerhorn Construction Date: 11/30/17 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Phone#2 Location tested: Building 10,Gentry Hill North Unit D City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume 8 x(432) +9 x (796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60= 61.95 cfm 1.5=16.8 2= 15.4 Minimum CFM50 = Airflow x N Factor 61.95 cfm x 15.4 = 954 CFM50 2. = .4 What#should be 3=13.7 Blower Door Diagnostics Ring Open Inside Temp: (D 2 F Baseline Pressure — Sn • Pa. B Outside Tem p: 30 F Fan Pressure Pa. C Flow @ CFM50= 0 vs"- NOTES: The safe zone for this home is+/-30%of the minimum CFM50 High side = 1240 @CFM 50 Low side= 667 @CFM 50 CFMP_50 x 60 minutes = 5 loo Volume of building x N factor 163548 ACH= New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. a reference,Energy Star Homes must come in at.35 ACH naturally to qualify. Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI GoldStar- Warrensburg, NY 12885 C O N T R A C T O R I D: 1006099 NEBPA BLOWER DOOR FORM -t Home Energy Experts NorM East Buildwg Performance Adr isors 518J50,S9141 Contractor: Schermerhorn Construction Date: 11/30/17 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Phone#2 Location tested: Building 10,Gentry Hill North Unit E City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume 8 x (432) +9 x (796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60= 61.95 cfm 1.5= 16.8 r'-2=15.4 Minimum CFM50 =Airflow x N Factor 61.95 cfm x 15.4 = 954 CFM50 2. = a What#should be 3= 13.7 Blower Door Diagnostics Ring Open Inside Temp: (p 1 F Baseline Pressure -0 . 1 1 Pa. B Outside Temp: 3 0 F Fan Pressure Pa. C Flow @ CFM50= ` Z 31 NOTES: The safe zone for this home is+/-30%of the minimum CFM50 High side= 1240 @CFM 50 Low side = 667 @CFM 50 CFMg50 x 60 minutes = 74c)40 Volume of building x N factor 163548 ACH= y New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. (As a reference,Energy Star homes must come in at.35 ACH naturally to qualify, Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI-GoldStar- Warrensburg, NY 12885 CONTRACTOR 1113: 11006099 NEBPA BLOWER DOOR FORM .► Home Energy Experts North East Buddiaq Performance Adr ison 518..850..99141 Contractor: Schermerhorn Construction Date: 11/30/17 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Phone#2 Location tested: Building 10,Gentry Hill North Unit F City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume 8 x (432) +9 x (796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60= 61.95 cfm 1.5= 16.8 rOO2= 15.4 Minimum CFM50 =Airflow x N Factor 61.95 cfm x 15.4 = 954 CFM50 2. _1 .4 What#should be 3= 13.7 Blower Door Diagnostics Ring Open A Inside Temp: -7 3 F Baseline Pressure - S'0. Z Pa. B Outside Temp: 30 F Fan Pressure 3 C. Pa. C Flow @ CFM50= ` � 0 NOTES: The safe zone for this home is+/-30%of the minimum CFM50 High side = 1240 @CFM 50 Low side= 667 @CFM 50 CFMk50 x 60 minutes = 0 0o Volume of building x N factor 1613,.548 ACH New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. (As a reference,Energy Star/tomes must come in at.35 ACH naturally to qualify. Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI GoldStar`" Warrensburg, NY 12885 C O N T R A C T O R 1 D: 1006099