Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-000276-2015
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000276-2015 Date Issued: Thursday, January 18, 2018 This is to certify that work requested to be done as shown by Permit Number CC-000276-2015 has been completed. Tax Map Number: 296.15-1-2 Location: 32 GENTRY HILL NORTH Owner: Schermerhorn Properties Applicant: Schermerhorn Properties This structure may be occupied as a: 4-unit Apartment w/attached garages SP 59-2012 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 QL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000276-2015 69 Tax Map No: 296.15-1-2 REVISED Permission is hereby granted to: Schermerhom Properties For property located at: 32 GENTRY HILL NORTH NORTH in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Address: 536 BAY RD Multi-Family-New $100,000.00 Queensbury,NY 12804 Total Value $100,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Schermerhom Properties 536 BAY RD Queensbury,NY 12804 Plans&Specifications 4-unit Apartment w/attached garages SP 59-2012 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,November 3,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queen before the /y�JPimt,,,iJJJon date.) Dated at the Town f Quee b f/ W d ovember 4,2015 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 WOW Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150111 Application Number: A20150111 Tax Map No: 523400-296-015-0001-002-000-0000 Permission is hereby granted to: SCH COTTAGE HILL. LLC For property located at: Gentry Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: SCH COTTAGE HILL, LLC 536 BAY Rd Suite 2 Fireplace QUEENSBURY NY 12804-0000 T Attached Townhouse $100,000.00 Total Value $100,000.00 Contractor or Builder's Name �Address Electrical Inspection Agency Y Plans&Specifications 2015-111 Cottage Hill Project bldg. #24 32 Gentry Hill North TOWNHOUSE 4-unit see SP 59-2012 $1,222.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, May 08,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T n of een ry 'Pay 08,2015 SIGNED BY , for the Town of Queensbury. Director of Building&Code Enforcement 4 FILE COPY y =._=_.r�_.-.., 010 OFFICE USE ONLY = 1 NO. PERMIT �01 E/ -1` TAX MAP ivrJ. PER!\ T NO. \ FEES: PERMIT RECREATION ENGINEERING (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION_ APPLICANT/BUILDER: •OWNER: 6 *- ADDRESS: S 5P( 2 ADDRESS: 000445154401 NN' I PHONE NOS. p,(2)__ — 'ict PHONE NOS. 144,046A ow,-CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: �s' PHOdNE: 6Y6-tc7S -t, LOCATION OF PROPERTY: exittiott*/ zii V- & `i 1,z-. 'AUL- sue. HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? EYES 0 NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: I I I CHECK ALL THAT p I I 0 (-- APPLY TO YOUR z t= cc p I cOr) cn , - w PROJECT r- cr 00 0J F _1 O = = i L. -1 LI- LI- aL u- W Q C- C, U w 0 C� z d HH E- 0F- CCwz Z < < — U) N co OLL I- Li_ Q = 0.'S SINGLE FAMILY W/O-FAMILY MULTI-FAMILY `` //� l P19 (NO.of UNITS 4 ) al J 3i� 1piIsi TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR 1 INDUSTRIAL ATTACHED cj 10 \- i QWP OTHER ! 1 Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 • Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: CornNee AM- M ESTIMATED CONSTRUCTION COST:t 1W,O . FUEL TYPE: ONT. S HEAT TYPE: 4,10nli4 *HOW MANY FIREPLACE(S): 4 AND/OR WOODSTOVES(S): ____O__ ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? 140 PROPOSED USE OF BUILDING OR ADDITION: 1A 'r ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 14,0 ARE THERE EASEMENTS ON PROPERTY? otot.1 oc:;-npata sapacate Application for Burning rfi^nram • I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laves and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree tAf, h- above. Signed A A, . Aeahfrat4://Afettavi-r tifoe A/&)d#LitAnlv-- Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office* 742 Bay Road, Queensbury NY 12804 • Revised 4/14/2010 • Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE r QUESTIONS? CALL 761-8256 OR EMAIL codes(4queensburv.net Office Use Only `�� VISIT OUR WEBSITE FOR MORE INFORMATION www.Queensburv.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office *742 Bay Road, Queensbury NY 12804 Office Use Only Town of Queensbury Building & Codes Received: Tax Map ID: FUEL BURNING APPLIANCE &CHIMNEY APPLICATION Permit No.: Permit Fee: $ Application is hereby made to the Building & Codes Office for the issuance of a Building & Use Permit pursuant to the NYS Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. Important Note To Applicant: Rouqh-In and Final Inspections Are Required: Date 2( -44 4 2o1f Owner Installer/Builder Address `{ Address Phone xis Phone Location of proposed construction and/or installation: e44114. L04141.16S etS, (i, r24 Contact Person for Building&Codes Compliance: $(Ltot, i $ i" e Subdivision Name: ‘4711-Pela 441 Fuel Burning Appliance Information Wood Coal Pellet Gas Oil Stove Fireplace Insert V Fireplace,factory built*— L- 1171141--- Fireplace, pLFireplace,Masonry Furnace, (Garage Only) *If Factory Built,Please Provide: Manufacturer Name: 6aittaftee Model No. 6.4-W0 Listed By: Number: Chimney Information Masonry** ✓check one _Block _Brick Stone Flue ✓check one Tile /Steel Size in Inches Material "check one _Double Wall _Triple Wall _Insulated Direct Vent _Chimney Liner If Non-Masonry,please provide: Manufacturer Name: Model No. Signatures: Alq j Print Name: . l;, ' - � s Signature: •. - • Date: ,006 ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 01/18/2018 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: OCC-Inspections Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Engineer [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Contractor [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal YES 32 Gentry Hill Dr. N-four unit building Exit Access FC1014&FC1029 YES Exit Enclosure FC1020&FC1029 YES Exit Discharge FC1024&FC1029 YES Truss ID Signage FC505.3 YES Clearance to Electrical FC 605.3 YES Electrical Wiring Enclosed/Labeled FC605.3.1 YES Combustibles in Equipment Rooms FC 315.2.3 YES F.D.Signage-FC510 YES Interior Finishes FC803-804 YES Smoke Detectors FC907 YES Tested OK CO Detectors FC610 YES Tested ok Clearance to Sprinkler/Ceiling FC315.2.1 18"/24" YES Sprinkler System Annual YES Received NFPA 13 letter from FireTek Sprinkler FDC YES Knox Box:installed/checked FC506 YES Occupancy Cycle YES R Stillman,Gary(Inspector) Jan 18,2018 Page(2) to, s SPRINKLER SYSTEMS, LLC 58 Hudson River Rd. • Waterford, NY 12188 Phone: (518)244-3772 Fax: (518)238-2608 1/18/18 Mr. Mike Palmer Fire Marshall Town of Queensbury 742 Bay Rd. Queensbury,NY 12804 RE: Cottage Hill Apts. 32 Gentry Hill North Queensbury,NY Mike, The installation of the fire sprinkler system, at the above address, has been completed. The system is on and operational. To the best of my knowledge the installation conforms to NFPA 13R. Should you require anything further, please give me a call. Sincerely, V,S) Bob Wood Vice President Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: P Inspection Date: 01/18/2018 Inspection Status: Passed , Inspector: Gary Stillman Inspection Type: s Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Engineer [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Contractor [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#Al 7F285011 Building Inspector Notes YES Unit A Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3 inch top,1 inch side.Exceeds installation manual Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening YES See page 15 of installation manual for clearance Return to verify 1/18/18 ok Witness Operation YES Return to verify 1/18/18 ok CO Detection YES Return verify 1/18/18 ok CSST Bonding YES Stillman,Gary(Inspector) Jan 18,2018 Page(2) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 01/18/2018 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Engineer [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Contractor [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285014 Building Inspector Notes YES Unit B Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES 3 inches top,1 inch sides-exceeds installation manual Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening YES See page 15 of installation manual for clearances Return to verify 1/18/18 ok Witness Operation YES Return to verify 1/18/18 ok CO Detection YES Return to verify 1/18/18 ok CSST Bonding YES Stillman,Gary(Inspector) Jan 18,2018 Page(2) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 01/18/2018 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhom Properties] Applicant [Schermerhorn Properties] Engineer [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Contractor [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285012 Building Inspector Notes YES Unit C Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3 inches top,1 inch sides.Exceeds installation manual Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Hearth not required per page 14 of installation manual Mantel-height above fp opening YES See page 15 of installation manual for clearances Return to verify 1/18/18 ok Witness Operation YES Return to verify 1/18/18 ok CO Detection YES Return to verify 1/18/18 ok CSST Bonding YES Stillman,Gary(Inspector) Jan 18,2018 � ��� Page(2) INSPECTION WORKSHEET (FMGAS-000384-2018) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 01/18/2018 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhom Properties] Applicant [Schermerhorn Properties] Engineer [Schermerhom Properties] Primary Owner [Schermerhom Properties] Contractor [Schermerhom Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285013 Building Inspector Notes YES Unit D Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3 inch top,1 inch sides required.Exceeds installation manual Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per installation manual page 14 Mantel-height above fp opening YES See page 15 of installation manual for clearances Return to verify 1/18/18 ok Witness Operation YES Return to verify 1/18/18 ok CO Detection YES Return verify 1/18/18 ok CSST Bonding YES Stillman,Gary(Inspector) Jan 18,2018 Page(2) „ A .. ,” a Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 10/19/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Contractor [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Engineer [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285013 Building Inspection notes YES Unit D Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3 inch top,1 inch sides required.Exceeds installation manual Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per installation manual page 14 Mantel-height above fp opening NO See page 15 of installation manual for clearances Return to verify Witness Operation NO Return to verify CO Detection NO Return verify CSST Bonding YES dr Stillman,Gary(Inspector) Oct 19,2017m _ m _ __ a m,� Page(1) INSPECTION WORKSHEET (FMGAS-006363-2017) Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 10/19/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Contractor [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Engineer [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285012 Building Inspection notes YES Unit C Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3 inches top,1 inch sides.Exceeds installation manual Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Hearth not required per page 14 of installation manual Mantel-height above fp opening NO See page 15 of installation manual for clearances Return to verify Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding YES Stillman,Gary(Inspector) Page(1) Oct 19,2017 t Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 10/19/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Contractor [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Engineer [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285014 Building Inspection notes YES Unit B Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES 3 inches top,1 inch sides-exceeds installation manual Vent Clearance to Combustibles YES Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening NO See page 15 of installation manual for clearances Return to verify Witness Operation NO Return to verify CO Detection NO Return to verify CSST Bonding YES Stillman,Gary(Inspector) Oct 19,2017 Page(1) , r' Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000276-2015 Case Module: Permit Inspection Date: 10/19/2017 Inspection Status: Partial Pass Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 32 GENTRY HILL NORTH Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Contractor [Schermerhorn Properties] Primary Owner [Schermerhorn Properties] Engineer [Schermerhorn Properties] Checklist Item Passed Comments Fire Marshal Notes YES SUPERIOR FIREPLACE MODEL#DRT2033TMN SERIAL#A17F285011 Building Inspection notes YES Unit A Floor Protection YES Clearances to Combustibles(all sides) YES Firestop(s)-Wall Penetration YES Vent Clearance to Combustibles YES 3 inch top,1 inch side.Exceeds installation manual Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension(if any) YES Not required per page 14 of installation manual Mantel-height above fp opening NO See page 15 of installation manual for clearance Return to verify Witness Operation NO Return to verify CO Detection NO Return verify CSST Bonding YES 4fippr Stillman,Gary(Inspector) Oct 19,2017 Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 Table 7:Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside comer outside corner Recessed Location See Table 6- I Ni j o H —G1— ! �/ igi MI Fo:e. E Operable Fzed I ./- ..--...----..- Balcony with No Side WI Balcony with Perpendicular side Wall d Closed _F_n Operable �-,� ---0-- _7�B Q1 1MI VI M 117_ MI E TERMINATION CAP O AIR SUPPLY INLET ®GAS METER t7 RESTRICTED AREA (TERMINATION PROHIBITED) U.S.Installation** Canadian Installation A Clearance above grade,veranda,porch,desk,or balcony 12"(300 mm)** 12"(300 mm)* B Clearance to window or door that may be opened 6"(150 mm) 6"(150 mm) for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW),and<50,000 Btu/h for fireplaces>10,000 Btu/h(3 kW) (15 kW), 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** C Clearance to permanently closed window 9"(229 mm) 12"(305 mm) recommended to prevent window condensation recommended to prevent window condensation 0 Vertical clearance to ventilated soffit located above the 18"(458 mm) 18"(458 mm) termination within a horizontal distance of 18"(458 mm) E Clearance to unventilated soffit 12"(305 mm) 12"(305 mm) F Clearance to outside corner 5"(127 mm) 5"(127 mm) minimum minimum G Clearance to inside corner 6"(152 mm)minimum 6"(152 mm)minimum H Clearance to each inside of center line extended above 36"(910 mm) 36"(910 mm) meter/regulator assembly within a height of 15 ft above the meter/regulator assembly** within a height of 15 ft above the meter/ regulator assembly* I Clearance to service regulator vent outlet 36"(910 mm)** 36"(910 mm)* J Clearance to nonmechanical air supply inlet to building or 6"(150 mm) 6"(150 mm) the combustion air inlet to any other fireplace for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW)and<50,000 Btu/h(15 kW), for fireplaces>10,000 Btu/h(3 kW) 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** K Clearance to a mechanical air supply inlet 36"(910 mm)above if within 10 ft(3 m)horizontally** 72"(1830 mm)* L Clearance above paved sidewalk or paved diveway located 84"(2130 mm)$ 84"(2130 mm)$ on public property M Clearance under veranda,porch,deck or balcony 12"(300 mm)*$ 12"(300 mm)*$ N Depth of alcove(maximum) 72"(1830 mm)** 72"(1830 mm)* 0 Clearance to termination(alcove) 6"(15.2 mm)** 6"(15.2 mm)* P Width of alcove(minimum) 36"(910 mm)** 36"(910 mm)* 0 Clearance to combustible above(alcove) 18"(457 mm)** 18"(457 mm)* * In accordance with the current CSA-B149.1 National Gas And Propane Installation Code ** In accordance with the curent ANSI Z223.1/NFPA 54 National Fuel Gas Codes $ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings *$ Only permitted if veranda,porch,deck,or balcony is fully-open on a minimum two sides beneath the floor 13 Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 nirect-Vent Gas Fireplaces 900004-00,04/2015 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8),with the following exception:The unit may not be recessed (allowance made for mantel legs/side trim in Figure 6).When the unit is installed with one side flush with a wall,the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 6). Table 8:Minimum Clearances * 1"(26mm)to wrapper for 45"model,all Back others 1/2"(13mm)to wrapper 0"(0 mm)to Spacers Sides 1/2"(13 mm)to wrapper 0"(0 mm)to Spacers** Top Standoffs 0"(0 mm)to top standoffs Floor 0"(0 mm) From Bottom of Unit to Ceiling 64"(1626 mm) Vent 3"(76 mm)—Top**** 1"(25.4 mm)—Sides and Bottom Front Service Clearance— 36"(914 mm) clearance immediately in front of viewing area(s) *3"(76 mm)above any horizontal/inclined vent component. **See Page 19 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. ***Top vent clearance can be reduced to 2"on horizontal runs when first elbow is located at least 6 f1 above the fireplace. The fireplace must be mounted on a fully supported base extending the full width and depth of the unit.The fireplace may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile or other combustible material other than wood flooring,the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Hearth Extension A hearth extension is not required with this fireplace. If a hearth extension is used, do not block the lower control compartment door.Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements. Shelf Height To provide for the lowest possible shelf surface, use the rear vent model. For top vent models,the venting attached to the top vent should be routed in a way to minimize obstructions to the space above the fireplace. Do not insulate the space between the fireplace and the area above it(Table 9 and Table 10).The minimum height from the base of the fireplace to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Table 9 and Table 10. Table 9:Combustible Shelf Height—Top Vent Top Vent with one 90°Elbow Model Secure Vent® Secure Flex®(flex elbow) DRC2033/DRT2033 44"(1118 mm) 46"(1168 mm) DRC2035/DRT2035 47"(1194 mm) 49"(1245 mm) 7 r l�l�ombustibles DRC2040/DRT2040 52"(1321 mm) 54"(1372 mm) or insulation Shelf Height in the shaded DRC2045/DRT2045 50"(1270 mm) 52"(1321 mm) (see table) area between the appliance and the shelf above it. moimmummim 14 Innovative Hearth Products Installation Superior•'DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 Table 10:Combustible Shelf Height—Rear Vent Rear Vent with two 90°Elbows Model >_3"clearance from shelf to Secure Vent® Secure Flex®(flex elbow) top of fireplace and/or vent DRC2033/DRT2033 34"(864 mm) 34"(864 mm) pipe,whichever is higher DRC2035/DRT2035 35 1/2"(902 mm) 351/2"(902 mm) Ir ���� DRC2040/DRT2040 401/2"(1029 mm) 401/2"(1029 mm) I ' combustibles Shelf Height or insulation DRC2045/DRT2045 451/2"(1156 mm) 451/2"(1156 mm) (see table) in the shaded ;� ' area between the appliance and the shelf above it. Figure 6:Combustible Side Clearances Figure 7:Mantel Height At 6"minimum side wall clearance,a combustible hi—Mantel depth wall can project Top View of 18(457) to any length. Fireplace / 16(406) f Combustible materials 14(356) I 3 1/2" allowed in shaded area `-- (89 mm) "Safe Zone". 12(305) Combustible walls 10(254) shown in dark gray 1 11 8 203 mem l -I r Combustible mantel ( ) ' legs may project a Hood beyond either side of (305) (203) (102). ----- - ---- the fireplace opening 6 2 as long as they are kept n.(mm) (254) (152) (51) n� -1___ within the shaded area Fireplace illustrated here. 6" (152 mm) Wall Finishes/Surrounds/Mantels NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the fireplace front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the fireplace face (Figure 41). Non-combustible materials,such as surrounds and other fireplace trim,may be installed on the fireplace face,but they must not cover any portion of the removable glass panel or control compartment. Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do not allow anything to hang below the fireplace hood. Minimum clearance requirements include any projections such as shelves,window sills, mantels, etc.above the fireplace. NOTE:To avoid heat-related finish damage,use finish materials rated 175°F, or higher,on the underside of the mantel. INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace, follow these steps: 1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction). 2. Remove the shipping pad, exposing the front glass door. 3. Remove the glass door(Page 57). NOTE: Place the glass door on the shipping carton to protect its surface. 15 c1°5 � ° — �( - 0 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection requ- .-. •. b V Queensbury Building&Code Enforcement Arrive: 3- D. ' pm Depart: ,,1 ..M110 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi NAME: C° /1 ( 6 e_,H' I tl PERMIT#: / I 1 LOCATION: r,-P `h--/ 1 No , INSPECT ON: k7/0 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 Foundation Inspection Report Office No. (518)761-8256 Date Inspection •quest re,'ei . 13112- )2Qk5 3.Queensbury Building&Code Enforcement Arrive: - d a ►i p-.4,40.- Depart: j,�as pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia - NAME: &.hQXYAC,V • l /'RMIT#: .2-°45—1 l LOCATION: �" M 32- �j ,4\1 SPECT ON: 8It3 I20,1S TYPE OF STRUCTURE: -241111111/1 Comments Y NN/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Plumbing Under Slab ifeP C/Cast/Copper Fo :• _ . ._ erior Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 11�'uj 10- 12. Foundation Inspection Report Office No. (518) 761-8256 Date Inspection r• -: re 7 8(1 Z 12C.1S Queensbury Building&Code Enforcement Arrive: k L ar Depart: C.00 a 742 Bay Rd., Queensbury,NY 12804 Inspector's Im a s: - NAME: SC.N,V YYvL✓inQa/r1 ' IT#: 201J 1 LOCATION: 0,43 22.E 26&-,'k„. f\- \ !(Vr.` V� INSPECT ON: a I�3 TYPE OF STRUCTURE: 4A, 1 Comments Y N N/A 18. Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 i- 5 Foundation Inspection Report Tom" V e v‘l Office No. (518) 761-8256 Date Ins ection request - -d: �' i2-- 2-C'13 Queensbury Building&Code Enforcement Arrive: \'�► b a`l. '-part: \119Z) 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial•• iw NAME: xmr vhciwr. PERMIT#: LOCATION: 64 Y 94 � 32 C.)- Keil th INSPECT ON: 2 It21 20,15 TYPE OF STRUCTURE: . Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for p VC� providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour YYY Reinforcement in Place ✓' Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 MCA 1-3 Foundation Inspection Report (,g.Anc-Arti ,C 3 Office No. (518) 761-8256 Date Inspection reque - - e: i CA , "" c Queensbury Building&Code Enforcement Arrive:;'`D a4-01T 4 D epart: ; :L. . p� 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi. ip• NAME: 3C21 ,Ylrykuvt'1-Q.N ' . ' IT#: l r II 1 i LOCATION: CO 2! JZ�� 4 �1�1 N• INSPECT ON: tl&Q V t TYPE OF STRUCTURE: 1 Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in PlaceN.,\/ E>LI-` C t- .� lL_. Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing ' 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 10- 12Z Foundation Inspection Report @ ems' I2.) Office No. (518) 761-8256 Date Inspection reque --ive.. 41 1 Queensbury Building&Code Enforcement Arrive: \-1.:-/D a pm -part: '77,35 pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials _, NAME: SilrY\StlIhn 'ERMIT#: )S'" t LOCATION: CAI- ' .5 ZG-lexik-yx," AI Op 'SPECT ON: '8 1-1-1 zcAS TYPE OF STRUCTURE: 4r'3 Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 Foundation Inspection Report L. v Office No. (518) 761-8256 Date Inspection reque recV .: 614l Queensbury Building&Code Enforcement Arrive: (12:Ira q ) Depart: jL_1T apm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: Sf_heirrfl +\SWv1 P' ' IT#: MS_149 LOCATION: i 31 Glzkitv -111i1 h INSPECT ON: ell 1204 S TYPE OF STRUCTURE: - ` Z_ \ %JV_ </:),4 Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place • The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab fr Backfill Approval Plumbing Under Slab PVC/Cast/Copper 0t` r„ an Insation Interior/Exterior R- \1ul .iJ ScL,AA Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 ?v►i Foundation Inspection P ection Re ort 1 t Office No. (518) 761-8256 Date Inspection re.4011 r ce. ed: 8 20A. Queensbury Building&Code Enforcement Arrive: 3:0('I a .��ri Depart: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial," NAME: 'On/rl P ' IT#: I S -I Q9 LOCATION: C " ,7)\ C`f\Fl V\ `` ,/h. :PECT ON: �, 3)Z0S TYPE OF STRUCTURE: T� Comments Y N N/A Footings g Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place _6 Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 0-12 Rough Plumbing I Insulation Inspection Report Inspection request received 1Z�1 z©15 Name 56 X )/ko,,n Inspected on 2[ t 5� I-1Z2_,c);\cl' Location Gt-4. 2� 10< v, t�,\l �a✓ 1 Arrive i) A )3111 Permit No. 2.o l5— Inspector's Initials i.11/4, Type of Structure pis COMMENTS C13 NA Plumbing under slab t - b2-185 g /Nail Plates Plumbing Vent /Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/ Head 5 P.S.I.or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape Blower Door Test Air Sealing Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 NEBPA BLOWER DOOR FORM Home Energy Experts NoiM Easr Building Performance Advisors 518.350.9941 Contractor: Schermerhorn Construction Date: 1-17-18 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Email: Location tested: 32 Gentry Hill North Unit A City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume (8 x 432) + (9 x 796) = 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60 = 61.95 cfm 1.5= 16.8 *Minimum CFM50 =Airflow x N Factor 61.95 cfm X 15.4 = 954 CFM50 3=13.7 Blower Door Diagnostics Ring Open A o Inside Temp: F Baseline Pressure — S Pa. B Outside Temp: z9� F Fan Pressure �1� �� Pa. C Flow CFM50= Z $ Z_ NOTES: The safe zone for this home is+/- 30%of the minimum CFM50 High side = 1240 @ cfm 50 Low side= 667 @cfm 50 p CFMg50 x 60 minutes = , � ` Z O Volume of building x N factor 163548 = � New York State Requires builders run a blower door test on new residential ACH %.j buildings to ensure a maximum air leakage of three air changes per hour. *As a reference.Enerey Star homes must come in at.35 ACH naturally to qualify. Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI°GoldStar" Warrensburg, NY 12885 CONTRACTOR 1 D: 1006099 NEBPA BLOWER DOOR FORM Home Energy Experts NoRb East Building Performance Adrisofs SISA 5941 Contractor: Schermerhorn Construction Date: 1-17-18 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Email: Location tested: 32 Gentry Hill North Unit B City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume (8 x 432) +(9 x 796) = 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60 = 61.95 cfm 1.5=16.8 *Minimum CFM50 =Airflow x N Factor 61.95 cfm X 15.4 = 954 CFM50 3= 13.7 Blower Door Diagnostics Ring Open A V Inside Temp: r057 F Baseline Pressure r Pa. B � q Outside Temp: Z� F Fan Pressure Pa. C Flow P CFM50= 3 c1 l NOTES: The safe zone for this home is+/-30%of the minimum CFM50 High side= 1240 @ cfm 50 Low side= 667 @cfm 50 ,/n CFM@50 x 60 minutes = V3 G"1y Volume of building x N factor 163548 ACH New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour. *As a reference.Enerey Star homes must come in at.35 ACH naturally to qualify �t Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI,GoldStar'" Warrensburg, NY 12885 CONTRACTOR I D: 1006099 NEBPA BLOWER DOOR FORM Home Energy Experts NofM Eau Building Performance Ad+isors 51&350.P9f1 Contractor: Schermerhorn Construction Date: 1-17-18 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone 41 518-798-0674 Email: Location tested: 32 Gentry Hill North Unit C City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume (8 x 432)+ (9 x 796)= 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60 = 61.95 cfm 1.5=16.8 *Minimum CFM50 =Airflow x N Factor 61.95 cfm X 15.4 = 954 CFM50 3= 13.7 Blower Door Diagnostics Ring Open A 0 Inside Temp: F Baseline Pressure O Pa. B Outside Temp: Zct F Fan Pressure 6 $ Pa. C Flow @ CFM50= ` 557 NOTES: The safe zone for this home is+/- 30%of the minimum CFM50 High side = 1240 @ cfm 50 Low side= 667 @cfm 50 CFM250 x 60 minutes = � � Ll Z'a Volume of building x N factor 163548 = � New York State Requires builders run a blower door test on new residential ACH J 7 buildings to ensure a maximum air leakage of three air changes per hour. *As a reference.Enersy Star homes must come in at.35 ACH naturally to qualify Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI,GoldStar- Warrensburg, NY 12885 C O N T R A C T O R 1113: 11006099 NEBPA BLOWER DOOR FORM 1 Home Energy Experts I. Nash Fair Building Performwcr Adruo" J18-Wl.JY101 Contractor: Schermerhorn Construction Date: 1-17-18 Contractor Address: 15 Birdie Dr Apt F City: Queensbury State:NY Zip: 12804 Phone#1 518-798-0674 Email: Location tested: 32 Gentry Hill North Unit D City: Queensbury State:NY Zip: 12804 Ventilation requirements Volume (8 x 432) +(9 x 796) = 10620 cb ft N Factor 1 = 19 Air Flow b .35 x (volume) 3717 /60 = 61.95 cfm 1.5= 16.8 2= 15.4 *Minimum CFM50 =Airflow x N Factor 61.95 cfm X 15.4 = 954 CFM50 35'-= 14.4 3= 13.7 Blower Door Diagnostics Ring Open A n Inside Temp: F Baseline Pressure Pa. B r Outside Temp: Z 9 F Fan Pressure — 56 Pa. C Flow a CFM-O= \ 3 n t NOTES: The safe zone for this home is+/-30%of the minimum CFM50 High side= 1240 @ cfm 50 Low side= 667 @cfm 50 (9 Volume CFM250 x 60 minutes = v �Z4y Volume of building x N factor 163548 New York State Requires builders run a blower door test on new residential ACH buildings to ensure a maximum air leakage of three air changes per hour. *Asa reference,Energy Star homes must come in at 35 ACH naturally to aualify. Blower Door testing performed by North East Building Performance Advisors 7 Rocky Ridge BPI°GpjdStar- Warrensburg, NY 12885 CONTRACTOR ID: 1006099