Loading...
2015-152 a TOWN OF QUEENSBURY two742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20150152 Date Issued: Monday, August 31, 2015 This is to certify that work requested to be done as shown by Permit Number P20150152 has been completed. Location: 462 STATE ROUTE 149 Tax Map Number: 523400-278-019-0001-009-001-0000 Owner: PATRICK & RUSTY-ROSE MELLON Applicant: PATRICK & RUSTY-ROSE MELLON This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or ( ow704 "digt- other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Flfirrg Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150152 Application Number: A20150152 Tax Map No: 523400-278-019-0001-009-001-0000 Permission is hereby granted to: PATRICK & RUSTY-ROSE MELLON For property located at: 462 STATE ROUTE 149 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PATRICK & RUSTY-ROSE MELLO 462 STATE ROUTE 149 Residential Addition $100,000.00 LAKE GEORGE,NY 12845 Total Value $100,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2015-152 Residential Addition 540 s.f. $108.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, May 14,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow eensb ; �/ i i r i J a ► ay 14, 2015 �lAir SIGNED BY ' for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATIONrr� ��, `�.,�office Use Only Date: t� V� I� Lateived Map ID Z Dr I Pedmit No. 2015 - 152— Tax 5ZTax Map ID MAY 1 1 2015 ,hermit Fee lab , • Zone Re•Fee Historic Site Yes No TOWN OF QUEENSBURY Sit,Plan# BUILDING& CODES Subdivision# Subdivision Name "mot#" TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS - SINGLE FAMILY, DUPLEXES/TWO-FAMILY, MULTIPLE FAMILY, APARTMENTS, CONDOMINIMUMS, TOWNHOUSES,AND/OR MANUFACTURED&MODULAR HOMES, BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. Applicant ` Owner -PA'r2�c�c. Mk\\s 3 SA rte? Address Address 1462 srq TC i2 r�"(5 /,A6t-2,rs< A/y ,264ir Phone/E-mail 5"Q —36►- ' a sg Phone/E-mail p •l•ca•-• Contact Person for Building&Codes Compliance: Phone TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1St floor sf 2nd floor sf Total sf Height Single Family X SC S—go / Two-Family Multi-Family (#of units ) Townhouse Business Office Retail-Mercantile Factory- Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 If commercial or industrial please indicate of business Proposed use of building or addition Source of Heat(circle one) Gas Oil Pop ne Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? N Are there easements on the property? N J Site Information a. Dimensions or acreage of lot b. Is this a corner lot? N 0 c. Will the grade be changed as a result of construction Yes k No d. Public water or Private well Wel e. Sewer or Private Septic System Se Pk;c- Value of all work to be performed (labor or materials) DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application,plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: ?Pv ;t .cic DATE: – 1 k SIGNATURE:�� �`�— DATE: S /e — zo1,- For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised September 2014 11W -RA Queensbury Building & Code Enforcement - Residential Final Inspection 1U1.w Office No. (518) 761-8256 1 Arrive: am/ epar. " am/pm Date Inspection request received: '(�fi\2_Q.XE Inspector's Initials: NAME: MELS Ni PERMIT#: 2.D i rJ 13 2-- LOCATION: 4L S 14'(1 DATE: 6 2-8L2-GAS TYPE OF STRUCTURE: ' �. C Comments: Yes No N/A_ 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location , Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches �Z Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more VzoV Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches ,r Deck Bracing/Handicapped Ramp Compliant Itj Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: V Ev Bedroom: • Outside every bedroo rea: Inter Connected: Battery backup: 4 Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans, if no window /" Plumbing fixtures 1( Foundation insulation to floor/Sticker on Panel ✓ Duct work sealed properly/Blower Door Test Certification Floor truss, draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%Z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% - -(I) j ' Final Survey Plot Plan `. Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required , Okay to issue C/C or C I 0 [Temporary/Permanent] - \ r U,SS t 6 S '1 -\&�c� o j l 6 19 r n P—cc�c� L:\Building &Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7, 2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 Town of Queensbury Building&Code Enforcement MtN Office No. (518)761-8256 I yvi Rough Plumbing I Insulation Inspection Report Inspection request received: x)15 Name: 1P)(1 Inspected on: 1140 Location: Lj la - 141 Arrive: p .m . . a / m. 1 Permit No.: 15 Inspector's Initials: A 1.11 OP' Type of Structure: Q-2`� . fid COMMENTS Y N NA Plumbing under slab Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant t f, Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation �..�^ �-�V' - If required unheated spaces � Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/ Insulation Inspection Report Town of Queensbury Building &Code Enforcement � ( Office No. (518)761-8256 �S Rough Plumbing I Insulation Inspection Report I ' Inspection request received: Name: 4\1\f,1(CC Cv-`- 1 Inspected on: / Le 0 411°M Location: P_ R.OU 1111/-41 Arrive: a.m. I p.m. Permit No.: ✓ 15 — f5J- Inspector's Initials: Type of Structure: COMMENTS Y N NA Plumbing under slab i.:Rough Plumbing / Nail Plates `/. Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head (1-1( 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test C �� Air Sealing (Hs Rough Plumbing I Insulation Inspection Report Town of Queensbury Building & Code Enforcement ✓/ /7 Office No. (518) 761-8256 Framing I Firestopping Inspection Report Inspection request received: ( i7/ j Name: Y "\ t 1,U ed Inspected on: Location: Z((1 X()()V l e- l"'t Arrive: / eft a.m.l p.m. Permit No.: 15 - i Inspector's Initials: TYPE OF STRUCTURE: if)r'\Thik) N N/A COMMENTS: `gaming Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided BracingI Bridging 99 Joist hangers ✓/ Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w)16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing /Firestopping Inspection Report IO�IZ Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 12 11'\ 5 Queensbury Building&Code Enforcement Arrive: am/pm Depart: a m 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: Lib- U • 14`1 INSPECT ON: b 11512 CL'F:' TYPE OF STRUCTURE: Comments Y N N/A eti� Footings Piers Monolithic Slab Reinforceme t i Place The con m cto is responsible for providin prot: tion from freezing for 48 hours fol owing the o acement of the concrete. Materi.i s for this .urpose .n site. •Foundatio /Wallpo Reinforce ent in Plac- Footing Dowels or Ke y in place Foundatio Dampproof Foundatio Waterproo int Footing P ain Dayli: t or 'ump Footing D ain Ston:. 12 inc width 6 inch:, above ooting 6 mil poly for et areas un.-r slab Backfill • ,.prov:l C Plumbing n. •r Slab PVC/Cas / opper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 _ bkAA Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 3 t5 Queensbury Building&Code Enforcement Arrive: am/pm Depar pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial •' (�� ` 3 NAME: Aqx n PERMIT#: 15 LOCATION: 1 (P2- INSPECT ON: b L 212O1/43 TYPE OF STRUCTURE: ,- Comments N N/A CAL___ 6 " (e 2-t Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Y Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval ily/ P.laitfig Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: 4-51-2-42115 Queensbury Building&Code Enforcement Arrive: am/pm Depart: . pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:/` p,A9 NAME: l''1l�—�5 2— �r n PERMIT#: LOCATION: 2 1 .Q.-@ut , ILO INSPECT ON: 517__L;)17.-QA a TYPE OF STRUC'TURE: (LQ!,- U. Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Z Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab ti PVC/Cast/Copper ,---- Foundation Foundation Insulation Interior/Exterior Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1