Loading...
2015-339 TOWN OF QUEENSBURY s� 742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201 ��� Q n', Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20150339 Date Issued: Tuesday, August 25, 2015 This is to certify that work requested to be done as shown by Permit Number P20150339 has been completed. Tax Map Number: 523400-296-008-0001-036-001-0000 Location: 68 WAVERLY PI Owner: ROSANNE LA FARR Applicant: ROSANNE LA FARR This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve therav,P 4 - 4\ property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code nforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY . i111ft1742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 IOW Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20150339 Application Number: A20150339 Tax Map No: 523400-296-008-0001-036-001-0000 Permission is hereby granted to: ROSANNE LA FARR For property located at: 68 WAVERLY P1 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ROSANNE LA FARR Deck $9,843.00 68 WAVERLY PI Total Value QUEENSBURY,NY 12804-0000 $9,843.00 Contractor or Builder's Name /Address Electrical Inspection Agency DO FOR YOU CONSTRUCTION 58 BRAYTON ROAD FORT ANN NY 12827-0000 Plans&Specifications 2015-339 Deck 161 s.f. Replacing original deck with new materials, not changing footprint $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,August 06,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the wn of uee ryi h,�sd. ,August 06,2015 �,Vf 4 SIGNED BY T ` for the Town of Queensbury. Director of Building&Code Enforcement Town of Queensbury Building & Codes Office Use Only Received ACCESSORY STRUCTURE APPLICATION Permit # 1-015 - 33 Permit Fee Ta Date ti JUL 3 0 2015 Recreation Fee T Tax Map ID #21_4e=9 l — \ Approvals Zoning TOWN OF QUEENSBUc Historic Site BUILDING &CODES Subdivision Name/Lot No. APPLICANT �)�%�� nNni` LAS-&g,,4. OWNER Address ']�y_t 2 gL _J / Address J.1-/jELrt .l iscT,� 1_6 Phone Phone (/ CONTRACTOR bc_�p,p VS';L _�� L'�ls v ESTIMATED COST OF CONSTRUCTION $ _9 . 6 7 Address _S i ,\O -0,J I Building Address: t,t,6.1,64=11-4/ Sir �n�vrtj_AUS ? Phone __ � __1266)-_�5 // CONTACT PERSON FOR BUILDING & CODES COMPLIANCE 1 "'iLL l�U3'C3k".e Phone -5 --02‘0'Z 23 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below 1st floor sq. ft. 2nd floor sq. ft. Total sq.ft. Height Boathouse Boathouse with Sundeck / Deck /44 f /�/�� 6/% RIO Detached Garage(# of cars) Dock Pole Barn Porch - Open **Porch - 3 season, Covered, Enclosed Shed Other ** Considered floor area and must comply with Floor Area Ratio requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true and complete statement description of the work proposed;that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances; and in conformance with local regulations. I acknowledge that prior to occupying the facilities proposed. I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I HAVE READ AND AGREE TO THE ABOVE: Print Name: __7-20",.4-r- ,}F&Q Date: 7 3o-/5 Signature: �—�-� Date: `7.3 Town of Queensbury Building & Codes -Accessory Structure Application - December 2014 I ... Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 (� Arrive: am/pm De• •: am/pm Date Inspection request received: I 1 /! Inspector's Initials: _, NAME: � - �(� PE- #: L< 33 LOCATION: .1 ( Ppi-i,( y /ft. i DATE: 411/�/',�'/VI TYPE OF STRUCTURE: / f Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs, decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss, draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s) installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3A hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0[Temporary/Permanent) L:\Building &Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7, 2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Framing / Firestopping Inspection Report Inspection request received: 541 U` 3.6 1.5-- Name: Name: ` ' C Inspected on: �� �' ,�1/ /S Si id C'� - - • Location: & i �� Arrive: �ti�►'� WOW . Permit No.: ,'e'i—' 339 Inspector's Initials: 141111111111 " TYPE OF STRUCTURE: �� YVN1---- NIA COMMENTS: Attic Access 22"x 30"minimum/ 1 Jack Studs I Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade ►esign Professional Sign-off, if required aming I Firestopping Inspection Report i_...rs,; _t ejz F" .-,z(,blti.2 / 1.• Ai: •:,, ,.. ,,--- , ,„ ''..2:. NaTe. ; Is ö :I) •- •"/i5 , .6‘) ,, 47:- . ,..'' c?c,...,c-rif,i ?go p oNe-b ,, t,.../ -,- --, beC/< .fkil e _ i I i / VIA X - 1-,. -I- _ TOWN OF QUEENSBURY BUILDING DEPARTMENT 1 , i 'i : Based on our limited examination,compliance 6 I 1 ' 1 1 ' with our comments shall not be construed as indicating the plans and specifications are in i , I 1 full compliance with the Building Codes of d . New York State R V TO ifTiri-OF-aU EENI§BU RY j fr_s", i , BUILDING& CODES ,'. i ( 74: ts FILE COPY , ! i i ft 4 _ , . I 1 Er ! i I . ii f 1 • ' 1 '!: 1----- ' i , I 1 { N' TOWN OF QUE Tor 1 1 fc.1A) BUILDING & C 4 D Reviewed By: ewiir , iT Date: 102111111, --- 0 r 1 . • - r— <4" typ, < 4" ty ...--10)•••••••••000 I 3; 7 • , .., min. 34" min. Required guards cannot consist of 1 horizontal rails or any ornamental > 30" Edi pattern that creates ladder effect I 6" sphere unable to pass through opening Section 8316