2015-364 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20150364 Date Issued: Friday, October 02, 2015
This is to certify that work requested to be done as shown by Permit Number P20150364
has been completed.
Location: 14 ZENAS Dr
Tax Map Number: 523400-301-012-0003-065-000-0000
Owner: JESSICA ZANNINI
Applicant: JESSICAZANNINI
This structure may be occupied as a:
Residential Alteration By Order of Town Board
/�
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property �
owner of the responsibility for compliance with Site Plan, Variance, or /GGGwwwiii���"
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20150364 Application Number: A20150364
Tax Map No: 523400-301-012-0003-065-000-0000
Permission is hereby granted to: JESSICA ZANNINI
For property located at: 14 ZENAS Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JESSICA ZANNINI Residential Alteration $35,000.00
14 ZENAS Dr Total Value
QUEENSBURY NY 12804-0000 $35,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
DJ BUILDING& CONSULTING
PO BOX 2246
MALTA.NY
Plans&Specifications
BP 2015-364
Repairs/Residential Alterations 975 sq. ft. - due to fire damage to home
$146.25 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,August 17,2016
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T(44J4 Queen i , ,August 17,2015
14
SIGNED BY ' ' \ for the Town of Queensbury.
Director of Building&Code Enforcement
•
PRINCIPAL STRUCTURE APPLICATION
Office Use Only
_ Received
Date: ¢3 h/�f r Tax Map ID
Tax Map ID 301. 1 a_3 _(os Permit No. �
Permit Fee lP L
Zone Rec Fee
Historic Site Yes No Site Plan#
Subdivision Name it A 4 4vG
I!)
TOWN BD. RESOLUTION 86-2013: $850 RE . TIO F 'O� E I! LLING UNITS - SINGLE
FAMILY, DUPLEXES/TWO-FAMILY, MUL I�•1ilD F LY, APART S, CONDOMINIMUMS,
TOWNHOUSES,AND/OR MANUFACTURED M! :aa -= anji. .BIIITtNO MOBILE HOMES. THIS
IS IN ADDITION TO THE PERMIT FEE. BUILDING&CODES
Applicant Do 6 u i I te1`. Owner S�Z,�- Z‘,.nrw t t
Address eo d o Z Z Address
rLe N\ 17-0Z0 p s / 1Z43 or
Phone/E-mail SIf3 99—//// Phone/E-mail 5-3 — i304 304
cic; cicis UtIPmf
Contact Person for Building&Codes Compliance: J.-3 Phone 87—t) Yqz
TYPE OF CONSTRUCTION
✓Check all that apply New Addition Alteration 1st floor sf 2°'floor sf Total sf Height
Family SingleCli7 (
r�
g (
Two-Family
Multi-Family --� �' d
kepüii ryttre
(#of units )
Townhouse
Business Office
Retail -Mercantile
Factory-Industrial
Attached Garage DJ Building & Consulting BP 2015-364
(1, 2, 3, 4+) 14 Zenas Drive
Residential Alterations due to fire damage
Other
I I I
Town of Queensbury Building&Codes Principal Structure Application Revised September 2014
•
If commercial or industrial please indicate of business
Proposed use of building or addition
Source of Heat(circle one) Gas Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances& Chimneys
Are there structures not shown on plot plan?
Are there easements on the property?
Site Information
a. Dimensions or acreage of lot
b. Is this a corner lot?
c. Will the grade be changed as a result of construction Yes No
d. Public water or Private well
e. Sewer or Private Septic System
Value of all work to be performed (labor or materials) $ $c -9
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application,plans and supporting materials are a true and complete statement/description of
the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building
laws and ordinances, and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy.
5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: 7 /7-/J7 DATE: & /�(ic
SIGNATURE: DATE: 6//1/4-ilt r
For office use only
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised September 2014
Queensbury Building & Code Enforcement - Residential Final Inspection
DateI No. coon 761-8256 Arrive: am/pm De art:( /pm
Date Inspection request received: � 1J� Inspector's Initials: /'
NAME: V1l n t PERMIT
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road J "
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake rJ 7 77
3 inch Plumbin Vent thr c m nrmu nches
Roof Complete/Exteri Finis Com lets
Platform at all exterior doors —
Handrail 4 or more risers
Guards at stairs,decks, patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall
Intedor/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safe lazin /Window in stairwells azrn
Interior Smoke Detectors/Ca ono '
Every level: Every Bedroom:
Outside every bedroom ea: _
Inter Connected: Bette badku
Attic aocess 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access,l sq.ft:150 sq.ft.vents
Bathroom Fans if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work seated properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergencv egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum 54"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'%hour fire door/door closer
Gas Los in Sealed or Glass Enclosure
Final Electrical;Energy Saving Li ht Bulbs 50%
Final Survey Plot Plan
Are Fault Breaker Habttable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspecdon Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 f Temporary/Permanent
L:\Building&Codes Fonns\Building&Codes\Inspection FormsWesidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 (4�
Rough Plumbing I Insulation Inspection Report
is
Inspection request received 1\it
Name 2y L4 C 1 se Inspected on qj t I i
Location �� 1/45 - Arrive /h/D f am 1 pm
Permit No. I �� y Inspector's Initials
Type of Structure
COMMENTS
Y N NA /� �. (`
Plumbing under slab /G C v�G x `
Rough Plumbing /Nail Plates / ?
�i
Plumbing Vent/Vents in Place (p l /
1 V2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet /change of direction
Pressure Test
Drain /Vent
Air /Head
5 P.S.I.or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
nsulation / Residential Check/ Commercial Check (c3,-. Ces
s It!
Window Sealing
Tyvek or Similar Exterior Sealant !pv
Proper Vent,Attic Vent
Door/Window Sealed (No Insulation)
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256