Loading...
CC-000344-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000344-2016 Date Issued: Monday, October 24, 2016 This is to certify that work requested to be done as shown by Permit Number CC-000344-2016 has been completed. Tax Map Number: 302.5-1-92.11 Location: 578 AVIATION RD Owner: AVIATION MALL NEWCO LLC Applicant: State Permits,Inc. This structure may be occupied as a:Interior Commercial Alterations (813 s.f. is being altered out of 1536 s.f. store) By Order of Town Board Kay Jewelers, Space C 101 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the /f ✓ property owner of the responsibility for compliance with Site Plan, �d Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: CC-000344-2016 Tax Map No: 302.5-1-92.11 Permission is hereby granted to: Kay Jeweler#1070 For property located at: 578 AVIATION RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: AVIATION MALL NEWCO LLC Retail-Mercantile-Alteration $200,000.00 Owner Address: 4 Clinton Square Total Value $200,000.00 Syracuse,NY 13202 Contractor or Builders Name/Address Electrical Inspection Agency Plans&Specifications Interior Commercial Alterations (8 13 s.f. is being altered out of 1536 s.f, store) Kay Jewelers, Space C 101 S 162.60 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday, June 8. 2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of¢ueensbu before the piration d t ,) Dated at the Town a Queene une 8, 2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: Permit No. • ?s�q"?1 t.s Tax Map ID Permit Fee 4 Ilia.C 0' lyly, 65i Zone Historic? _Yes >el No Ree Fee Subdivision Name NO—+M Kalu Lot# Site Plan# Subdivision# Project Location ia,fi Uol TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Address Cliw 9V rok.cwu- tJ 13 2,0 Phone/Email Applicant soul Address t r+c�✓ Ct t Lc. !Ni S 3S Phone/Email Contractor Address Phone/Email Contact Person for Building& Codes Compliance: Avg i+o&tsm Phone l,(06.'?o'7.9083 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 2nd floor sf Total sf Height Single Family i Two-Family -9 L "" Multi-Family ,u{� (#of units�� y Vib Townhouse Business Office Retail -Mercantile 3 L 3 tots Factory-Industrial Attached Garage (1, 2. 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Gas Oil Propan Solar Other GWS Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? /A- Are AAre there easements on the property? /1! Site Information: a. Dimensions or acreage of lot S+ b. Is this a corner lot? Yes No c. Will the grade be changed as a result of construction Yes No d. Public water or Private well(circle one) Pub ' Private e. Sewer or Private Septic System(circle one) ew Private Value of all work to be performed (Iabor or materials) $ 7A000 DECLARATION. I. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy, 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: DATE: (¢ x71/4e SIGNATURE: a141-N DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 COMcheck Software Version 4.0.2.8 Interior Lighting Compliance Certificate CS11 o M m � 00 o a, Project Information V) CL O Energy Code: 2014 New York Energy Conservation Construction Code Project Title; Kay#1070 Aviation Mall V Project Type: New Construction tY Q Construction Site: Owner/Agent: Designer/Contractor: tV r O Signet jewelers Ltd. Nick Zalany Ch, + v 375 Ghent Road Jencen Architecture a) Akron, OH 44333 2850 Euclid Ave Q CL tV Additional Efficiency Package Cleveland, OH 44115 3h 00 O R f-, O tYf �C Ln V Unspecified Allowed Interior Lighting Power FILE COPY A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts!ft2 (B X C) 1-Retail:Sales area 1208 1 .60 1933 Allowance:Jewelry,crystal,china highlighting 1 Fix. ID:CKA 127(a) 2.50 318(b) Allowance:Jewelry,crystal,china highlighting 1 Fix.1D:CKA1 60(a) 2.50 150(b) 2-Common Space Types:Storage 106 0.80 85 3-Common Space Types:Restroom 62 1 62 Supplemental Allowed Watts(null)= 140 Total Allowed Watts= 2687 (a)Area claimed must not exceed the illuminated area permitted for this allowance type. (b)Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less. (c) Supplemental watts must be associated with retail merchandise highlighting fixtures.Supplemental watts are not included calculation of lighting complaince percentage. Proposed Interior Lighting Power A B C D E Fixture ID : Description!Lamp/Wattage Per Lamp 1 Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-RetaiLSales area aE —( n CKA:CKA:Sales area lighting:Other: DE ��V! LCL 1 32 33 1056 CKA1:CKA1:Sales area lighting:Other. I� 110 33 330 CKD:CKD:Sales area lighting:Other: ��II� f ; 1 16 33 528 R8: R8:Decorative pendant:LED A Lamp 1 V4 JUN 03 2016 3 3 45 135 CKE:CKE:Sales area lighting:Other: 1 1 33 33 KH: KH:Cove lighting:Other: L1 80 6 480 Space p ' 2-Common S T es:Stora T07171 E NSBURY mm:mm:Stock room lighting:48"T8 32W: eetfor�ieBUILDING & CODES-----�--- 2 2 50 100 3-Common Space Types:Restroom BB: BB:Toilet room lighting:22"T5 HO 24W:Electronic: 1 1 25 25 Total Proposed Watts= 2687 Project Title: Kay#1070 Aviation Mall Report date: 05123/16 Data filename: H:ISterlingllights in progess\SIGNET LIGHTS.cck Page 1 of 6 Interior Lighting : Passes using retail merchandise highlighting supplemental watts. Interior Lighting Compliance Statement � f~© Afi'r, Compliance Statement: The proposed interior lighting design r rese +s1f+48utkn istent with the building plans, specifications, and other calculations submitted with this permi ppli 3h propose- Yjb. 'ghting systems have been designed to meet the 2414 New York Energy Conservation Con ct� n 6 e rTepuir�` ts'lii q6eck Version 4.0.2.8 and to comply with the mandatory requirements listed in the Inspecti hit t� - _ �.� N14#oLA&-,P, 2AtAAjv- Awl Name-Title Signatu ,� 4 -�;r-� Date Nov Project Title: Kay#1070 Aviation Mall Report date: 05/23/16 Data filename: HASterlingllights in progess\SIGNET LIGHTS.cck Page 2 of 6 COMcheck Software Version 4.0.2.8 Inspection Checklist Energy Code: 2014 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions &Re .ID 0103.2 Plans,specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information []Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. C406 Plans, specifications, and/or ❑Complies Requirement will be met. [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ❑Not Observable efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Kay #1070 Aviation Mall Report date: 05/23/16 Data filename: H:ISterlingllights in progess}SIGNET LIGHTS.cck Page 3 of 6 section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. Automatic controls to shut off all ❑Complies Requirement will be met. 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ❑Not Observable ❑Not Applicable C405.2.1. Independent lighting controls installed ❑Complies Requirement will be met. 1 per approved lighting plans and all ❑Does Not [EL23]2 manual controls readily accessible and ❑Not Observable visible to occupants. ❑Not Applicable 0405.2.1. Lighting controls installed to uniformly ❑Complies Requirement will be met. 2 reduce the lighting load by at least ❑Does Not [EL1511 50%. ❑Not Observable ❑Not Applicable C405.2.2. Daylight zones provided with ❑Complies Exception: Requirement does not apply. 3 individual controls that control the ❑Does Not [EL16]2 lights independent of general area ❑ lighting. Nat Observable ❑Nat Applicable C405.2.3 Sleeping units have at least one ❑Complies Exception: Requirement does not apply. [EL17]3 master switch at the main entry door ❑Does Not that controls wired luminaires and switched receptacles. ❑Not Observable ❑Not Applicable C405.2.2. Occupancy sensors installed in ❑Complies Requirement will be met. 2 required spaces. ❑Does Not [EL18]1 ❑Not Observable ❑Not Applicable 0405.2.2, Primary sidelighted areas are ❑Complies Exception:Requirement does not apply. 3 equipped with required lighting ❑Does Not [EL20]1 controls. ❑Not Observable ❑Not Applicable C405.2.2. Enclosed spaces with daylight area ❑Complies Exception: Requirement does not apply. 3 under skylights and rooftop monitors ❑Does Not [EL21]1 are equipped with required lighting ❑ controls. Not Observable ❑Nat Applicable C405.2.3 Separate lighting control devices for ❑Complies Requirement will be met. [EL411 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable 0405.4 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. [EL6]1 face. ❑Does Not ❑Not Observable ❑Not Applicable C405.2.3 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and ❑Not Observable separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 1 JHlgh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Kay#1070 Aviation Mall Report date: 05/23/16 Data filename: H:1Sterlingllights in progess\SIGNET LIGHTS.cck Page 4 of 6 Section # Final Inspection Complies? Comments/Assumptions & lie .ID _ C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 30 days ❑Does Not [F[16]3 of system acceptance. ❑Not Observable ❑Not Applicable C303.3,C4 Furnished O&M instructions for ❑Complies Requirement will be met. 08.2.5.2 systems and equipment to the ❑Does Not [FI17]3 building owner or designated representative. ❑Not Observable ❑Not Applicable C405.5.2 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting ❑Not Observable plans, demonstrating proposed watts are less than or equal to allowed ❑Not Applicable watts. 0408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration,adjustment, ❑Does Not programming, and operation. ❑Nat Observable ❑Not Applicable 0406 Efficient HVAC performance,efficient ❑Complies Requirement will be met. [FI34]1 lighting system, or on-site supply of ❑Does Not renewable energy consistent with what is shown the approved plans. ❑Not Observable ❑Nat Applicable Additional Comments/Assumptions: 11 High Impact(ler 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 31 Project Title: Kay#1070 Aviation Mall Report date: 05/23/16 Data filename: H:1Sterlingilights in progess\SIGNET LIGHTS.cck. Page 5 of 6 Project Title: Kay#1070 Aviation Mail Report date: 05/23/16 Data filename: H:XSterling\lights in progessNSIGNET LIGHTS.cck Page 6 of 6 FIRE MARSHAL'S OFFICE Toum of Queensbury 742 Bay Road, Queensbtcry, NY 12804 " Hone of Natural Beauty ... A Good Place to live " PLAN REVIEW Kay Jewelers 578 Aviation Road, Space C101 CC-000344-2016 6/8/2016 1 have reviewed the submitted drawings for the above project, and offer the following comments: 1) Provide NFPA 13 letter at completion for sprinkler system modifications. 2) Exit / emergency lights appear adequate, a function test shall be witnessed by the Fire Marshal's office prior to CO. Breaker shall be marked for future Fire Marshal test of same. 3) Verify fire extinguisher (2) locations per plan. C4PK— 1 7; ;:z Deputy Fire Marshal Gary K. Stillman 742 Bay Road MF- Copy Queensbury NY 12804 518 761 8205 garys@queensbury.net Fire M a r s h a I 's Office - Phone: 518-761-8206 - Fax: 518-7454437 .fiieiiiat•slial@gtteeiisburtliiet ■ wwzv.queensbun1 izet FIRE MARSHAL'S OFFICE Tort}n of Queensbury 742 Bay Rona, Queensbury, NY 12804 " Horne of Na tit raI Beauty ... A Goon Place to Live " PLAN REVIEW Kay Jewelers 578 Aviation Road, Space 0101 CC-000344-2016 61812016 1 have reviewed the submitted drawings for the above project, and offer the following comments: 1) Provide NFPA 13 letter at completion for sprinkler system modifications. 2) Exit/ emergency lights appear adequate, a function test shall be witnessed by the Fire Marshal's office prior to CO. Breaker shall be marked for future Fire Marshal test of same. 3) Verify fire extinguisher (2) locations per plan. 4Deut'� Fire Marshal Gary K. Stillman 742 Bay road Queensbury NY 12804 518 761 8205 garys@queensbury.net FILE SKCOPY Fire Marshal 's Office - Phone: 518-761-8206 Fat: 518-745-4437 frrernarsltal ftieensbitn1.tiet - zmvrv.queensbumnet