Loading...
RC-000105-2016 G N 40- kA kA W as 71 �D 'a V) U y ,© W Fn p o w -d © o O � o cv � �i cz c0 F 4 rq 'C V C ;:3 z 4-1 44 W C=> °� Q n O/ CY pq ��✓✓ p ccs � N o oth p U cd Z o �. o bill TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)76I-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-000105-2016 Tax Map No: 295.19-1-28 Permission is hereby granted to: Rozell Industries Inc. For property located at: 9 SHERWOOD DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance TVoe of Construction Owner Name: Edward Miller Single Family-Addition $30,000.00 Owner Address: 9 Sherwood DR Total Value $30,000.00 Queensbury,NY 12804 Contractor or Builder's Name I Address Flectrical Inspection Agency Rozell Industries Inc. 129 Park RD Queensbury,NY 12804 Plans&Specifications SFD Alterations, 1730.51 s.f. PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,February 24,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before th xpiration date. Dated at the Toe Que ury; re 1.2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: ©Z- 26?-1(p Permit No. C` Tax Map ID .2q5- 19 — 1- 215 Permit Fee Zone MR- Historic? Yes �-N�°. i,y Rec'Fee Subdivision Name 1 ' Sitelaii! �_,.._.__ �Subdiiv Project Location TOWN Bl).RESOLUTION 86.2013: $850 recreation fee foi new elliag,ur�its�- jOpl I roily dupliqxes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufaci ured ( (� r �I,bl�a s, €� ia#riel5bile times. This is in addition to the permit fee(s). $� t �` I1dG C i?r}€ Primary Owner(s) a 7 my l ctt- Address q 51-k�t;,ulo�4 �1L. � �uEEN5r3UR.k �+J� l2Bp� Phone/Email �nyt �I{,►�@- ��$ �y Geo r .�o m �1$- 3b! - 141� Applicant Ph I`hhf_4 Dari f, 3 6TwU P Address �)i 2 PhonefEmailP i n til i n rlew OU Srr 9 n Lo rn S - 5 a7-7/2c yc Z B Contractor ozC{{ 101)0`a;VPL.E.5 I loc. Address (Z9 TAlz1/- P-t3 i ��l✓+ �'J� `! Phone/Email "ATJ RD z.e l l - 51$- Contact Person for Building& Codes Compliance: DIVPJ A PER O Phone 587 11W x 7- TYPE TYPE OF CONSTRUCTION ✓Checlt all that apply New Addition Alteration I'floor sf 2°$floor sf Total sf Height Single Family 8 l,3 J21-(67-5 1 ,Z30.5 J 17 3`, Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? 00 Are there easements on the property? K10 Site Information: a. Dimensions or acreage of lot W P4, b. Is this a corner Iot? Yes v No c. Will the grade be changed as a result of construction Yesy No d. Public water or Private well (circle one) ubli Private e. Sewer or Private Septic System (circle one) Sewer nvate Value of all work to be performed(labor or materials) $ 30,000 15©M ATV-D #orz. DECLARATION.- M Otto 1. 1 acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the I year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: P/ -�1 `L �,!lit l� DATE: SIGNATURE: DATE: _f�a For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 REScheck Software Version 4.6.2 Compliance Certificate Project Miller Residence Energy Code: 2010 New York Energy Conservation Location: Warren County, New York Construction Type: Sing[e-family Project Type: Addition Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 9 Sherwood Dr. Edward Miller Michael Phinney Queensbury, NY 12804 9 Sherwood Dr. Phinney Design Group Queensbury, NY 12804 142 Grand Ave. Floor 2 Saratoga Springs, NY 12866 Compliance: 3.2%Better Than Code Maximum CIA: 93 Your UA: 90 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Wall 1: Wood Frame, 16" o.c. 194 21.0 0.0 0.057 10 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 24 0.280 7 Wall 2: Wood Frame, 16" o.c. 194 21.0 0.0 0.057 9 Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 22 0.280 6 Door 2: Glass 18 0.270 5 Wall 3: Wood Frame, 16" o.c. 196 21.0 0.0 0.057 10 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.280 3 Wall 4: Wood Frame, 16" o.c. 196 21.0 0.0 0.057 11 Ceiling 1: Flat Ceiling or Scissor Truss 461 38.0 0.0 0.030 14 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 461 30.0 0.0 0.033 15 Compliance Statement. The proposed building design described nt with the building plans,specifications,and other calculations submitted with the permit application.The propos c designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck I wit the mandatory requirements listed in the REScheck Inspection C ecklist. Na a-Title5gna Date ,X9 02sg � r OF NO Project Title: Miller Residence Report date: 02/25/16 Data filename: IISBS2011\Data\Phinney Shared Drive116000 Non-contracted jobs\16000-02 Miller Page 1 of 6 Residence1022516 ResCheck.rck REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section I Pians Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.2 Construction drawings and ❑Complies Requirement will be met. [PR111 documentation sufficiently ❑Does Not demonstrates energy code compliance for the building []Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies Requirement will be met. 403.7 documentation sufficiently ❑Does Not [PR311 demonstrates energy code -) compliance for lighting and []Not Observable mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: OComplies Requirement will be met. [PR212 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not on loads per ACCA Manual J or� g; g []Not Observable' other approved methods. Coalin Cooling: Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: I I High Impact(Tier 1) 2 1 Medium Impact('tier 2) 3 1 Low Impact(Tier 3) Project Title: Miller Residence Report date: 02/25/16 Data filename:\\SBS2011\Data\Phinney Shared Drive\16000 Non-contracted jobs\16000-02 Miller Page 2 of 6 Residence\022516 ResCheck.rck Section # Foundation Inspection Complies? Comments/Assumptions &Req.11k 303.2.1 Exposed foundation insulation OComplies Requirement will be met. IF01112 protection. ODoes Not []Not Observable Location on plans/spec:Sections A4.1,A4.2.A4.3 ONot Applicable 403.8 Snow melt controls. OComplies Exception:Requirement is not applicable. IFO1212 ❑Does Not 1' ❑Not Observable ONot Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Miller Residence Report date: 02/25/16 Data filename: 11SBS20111Data\Phinney Shared Drive116000 Non-contracted jobs116000-02 Miller Page 3 of 6 Residence\022516 ResCheck.rck Section Plans Verified Fleld Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions 1,1� Re .IB 402.4.4 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/l.S.2/A440 or has infiltration rates per NFRC []Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate⁢=2.0 ❑Not Observable Location on plans/spec: servae cfm leakage at 75 Pa. Cover Sheet A0.0 ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies Requirement will be met. [FR13I1 air handlers,filter boxes,and ❑Does Not building cavities used as return ducts are sealed. ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not []Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- OComplies Requirement will be met. [FR17]2 above 105 OF or chilled fluids ❑Does Not ,- below 55 4F are insulated to R-3. ❑Not Observable ❑Nat Applicable 403.4 Circulating service hot water R- R- ❑Complies Requirement will be met. [FR18]2 pipes are insulated to R-2. ❑Does Not ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not Intakes and exhausts. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Ter 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Miller Residence Report date: 02/25/16 Data filename: \1SBS2011\Data\Phinney Shared Drive116000 Non-contracted jobs\16000-02 Miller Page 4 of 6 Residence\022516 ResCheck.rck Section # Insulation Inspection Complies? Comments/Assumptions &Req.10r 303.1 All installed insulation labeled or ❑Complies Requirement will be met. VN1312 installed R-values provided. []Does Not V' ONot Observable ONot Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Miller Residence Report date: 02/25/16 Data filename:\\SBS2011\Data\Phinney Shared Drive\16000 Non-contracted jobs\16000-02 Miller Page 5 of 6 Residence\022516 ResCheck.rck Section Plans Verified Field Verified # Final Inspection Provisions value Value Complies? Comments/Assumptions &Req.l>d 402.4.2. Building envelope tightness ACH 50= ACH 50= ❑Complies Requirement will be met. 402.4.2.1 verified by blower door test result ❑Does Not [FI17]1 of⁢7 ACH at 50 Pa.This requirement may instead be met ❑Not Observable via visual inspection,in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm ❑Complies Exception: All ducts and air [F1411 construction with maximum ❑Does Not handlers are located within leakage of 8 cfm to outdoors,or conditioned space. 12 cfm across systems.For ❑Not Observable p rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed on forced air furnaces. ❑Does Not ,W []Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies Exception: Requirement is [FI11]2 systems have automatic or ❑Does Not not applicable. accessible manual controls. []Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [F17]2 ❑Does Not 14 ❑Nat Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Miller Residence Report date: 02/25/16 Data filename:\\SB52011\Data\Phinney Shared DCIve\16000 Non-contracted jobs116000-02 Miller Page 6 of 6 Residence1022516 ResCheck.rck 2010 New York Energy Conservation Construction Code Energy Efficiency Gertificat Insulation hating R-Value Above-Grade Wall 21.00 Below-Grade Walt 0.00 Floor 30.00 Ceiling 1 Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.28 Door 0.27 HePting4CoPlingEquiprnent Heating System: Cooling System: Water Heater: Name: Date: Comments