Loading...
RC-000436-2016 TOWN OF QUEENSBURY 'I 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 N. Community Development-Building&Codes (518)761-8256 CF,RTIFICATF, OF OCCUPANCY Permit Number: RC-000436-2016 Date Issued: Monday, July 16, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000436-2016 has been completed. Tax Map Number: 252.-1-36.6 Location: 268 LOCKHART MOUNTAIN RD Owner: JAMIE JOHNSON .Applicant: CERRONE BUILDERS,INC. This structure may be occupied as a: Single Family Dwelling 4070 s.f. 1 fireplace in Master Suite By Order of Town Board 1 fireplace in Living Room TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the (.7116 j 4 property owner of the responsibility for compliance with Site Plan, \ Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 4i- Community Development - Building& Codes (51 S) 761-8256 BUILDING PERMIT Permit Number; RC-000436-2016 Tax Map No: 252.-1-36.6 Permission is hereby granted to: CERRONE BUILDERS, INC. For property located at: 268 LOCKHART MOUNTAIN RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: JAMIE JOHNSON Single Family-New $600,000.00 Owner Address: 268 Lockhart Mountain RD Total Value 5600,000.00 Lake George,NY 12845 Contractor or Builder's Name/Address Electrical Inspection Agency CERRONE BUILDERS, INC. 1589 State Route 9 Fort Edward,NY 12828 Plans&Specifications Single Family Dwelling 4070 s.f. 1 fireplace in Master Suite I fireplace in Living Room $ 914.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday,July 8, 2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Que bury; W s y 13,2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement "KI NC IVAL S'1'KUC TUKL+` APPLICATION Office Use Only ►Date: /'/ / ' - Permit No. - - Tax Map ID tJ'z• -` �lfl • Permit Fee #3 14'.UOQ V by. _T Zone Historic? _Yes No Rec Fee - Subdivision Name Lot # Site Plan Subdivision# Project Location C Otiu Lima P TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses, and/or manufactured &modular homes, but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Ayu cSYV Address 12-0- 6c r 6lf&T141 Phone/Email 2 _ 6 Applicant Address Phone/Email Jr d Contractor 0f__7t1Zc7XA-F' �3tic LOCAJ AL/c . Address Phone/Email 141 Contact Person for Building & Codes Compliance: T7 q 612P-4-X16 Phone TYPE or CONSTRUCTION ,/Check all that apply New Addition Alteration 1St floor sf 2nd floor sf Total sf Height Single Family i j i Q' Two-Family Multi-Family (# of units Townhouse Business Office Retail -Mercantile Factory- Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances&Chimneys Are there structures not shown on plot plan? AJO Are there easements on the property? AJ Site Information: a. Dimensions or acreage of lot , 2 b. Is this a corner lot? Yes No c. Will the grade be changed as a result of construction Yes ..V No d. Public water or Private well(circle one) Public Private e. Sewer or Private Septic System(circle one) Sewerrivate Value of all work to be performed(labor or materials) is DECLARATION.- 1. ECLARATION.1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement I description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I I we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: de7w-6ye— DATE: 71-7/110 SIGNATURE: DATE: 7/7 Ato For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 CHECKLIST—SINGLE FAMILY PROJECT Project Name: (Uktha AUAJT41 REQUIRED—2 SETS Yes No N/A 1. Building Permit completed �( 2. Energy Code inspector's report from REScheck completed 3. Septic alteration 4. Solid Fuel Burning or Gas Appliance form completed 5. Driveway Permit X }� 6. Structural Drawings a. Floor plans x b. Foundation plans c. Cross Sections d. Elevations k e. Window&Door Schedule x f. Natural Light,Ventilation and Emergency Egress 7. Plot plan: Show proposed structure(s)with setback dimensions from all surveyed property lines 8. Electrical inspection agency selected �( CHECKLIST—MULTI-DWELLING/COMMERCIAL Project Name: REQUIRED—2 SETS Yes No NIA 1. Building permit application completed 2. Energy Code COMcheck and inspector's report form completed 3. Septic alteration 4. Solid Fuel Burning or Gas Appliance form completed 5. Driveway Permit 6. Structural Drawings a. Floor plans b. Foundation plan c. Cross Sections d. Elevations e. Design loads including floor, snow&wind load f. Seismic design g. Plans signed&sealed by registered architect or engineer h. Window&Door schedule 7. Plot plan: Show proposed structure(s)with setback dimensions from all surveyed property lines 8. Electrical inspection agency selected Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: 7b / Tax Map ID TAx MAP ID: Permit No. Permit Fee ZONE: OWNER PHONE/E-MAIL L _ ' ADDRESS ' L INSTALLER/ PHONE/E-MAIL BUILDERdX&xc- 6q� ., CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: .'?�`CZ✓V� PHONE/E-MAIL J Y S `jQ 0 BUILDINGADUREss L' Loterhyr A t/1h[xFT y j ' ' ARM PLANNED INSTALL DATE: ROOM OF INSTALL: f/y after �,9[4P �I 't,�� FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name; _ `IC ; Model#: 3ec) Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: • Model#: /�X/L DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: 72E DATE: 7/7 1� SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only -7 Received f DATE: 7li Talc Map ID TAx MAP ID: Permit No. Permit Fee ZONE: OWNER PHONE/E-MAIL u _ r ADDRESS INSTALLER/ - PHONE/E-MAIL BUILDER +� X % �l `t�'4P 60 CONTACT PERSON FOR B/UILDIN/G�&—CODE COMPLIANCE ey'&V E PHONE/E-MAIL J `t S `Jp J 0 0 BUILDING AD � S _246 LIA.I�C� UbC7t +J ROOM OF INSTALL: t $( /}�j�7� PLANNED INSTALL DATE: 616her 2,0149 FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED' FIREPLACE,FACTORY BUILT* NOTE: MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE{GARAGE ONLY MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: 471L ?7G ;Model#: dt) Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ; Model#: Z b ?G) DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Cade and/or manufacturer requirements. The applicant or Owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: -a- DATE: 7/7 ► SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: 71-7h fv _ Tax Map ID TAX MAP ID: Permit No. Permit Fee ZONE: APPLICANT u /�� PHONE/1rMAIL d ADDRESS , AIVI2 �� INSTALLER/ f PHONE I E-MAIL BUILDER /c OWNER d i sd,,!�' ADDRESS CONTACT PERSON FOR BUILDING ff&CODE COMPLIANCE: Btt/Er PHONE/E-MAIL V�'(2, d RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed _Yes )'(�o 1981-1991 Spa or Hot Tub installed Yes)c/No 1992-Present ] PARCEL INFORMATION Topography Flat rolling Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size =gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length ZO() ft.;Each Trench Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and all requirements of the wn of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: TI � � DATE: _ /. 74 SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 O �t -Ir o ' o y 'S a ~, U N a .� 3 - s v� v roo •� 43 o a O v t j � "vi -• � � bA bA U ,� civ O N � � ,�4 •� ,� � bA trp � �3 Mo H 3 � 0 0 w o o o a O a� � o .-� .c� 'i3 *ts o o Cf) U U rn - o �r -T vi _ ti Lo rp a 0 � � V o •U o 0 .� •� � a N 'C � U � x U •� x v bA bA bo �yj v Q G O O O Ey o o o d �° Q 0 o� C9 C:Z) a t — o U C 0 pa u x x z o o a a x a jY Q d Qui �e �i Cly V1 U L) �. 0 W w cs� c y > w Q &OD a z O N P W -d o _ x -64 x a U •U e z a 9 y a a z Q c a o Z ° A Y /NA Residential Plan Review: One&Two Family Dwellings Two(2)full sets of plans Over 1,500 sq.ft.requires engineering stamp Design loads on plans:. 90 Wind Floor Loads 40 psf (north of Rt.149 60) 50 Ground Snow Load Sleeping Areas&Attics 30 psf Calculations Window schedule with glass size Door schedule/Main entrance 36"door Emergency Escape or Bedrooms and Habitable Space Above/Below grade: 5.7 sq.ft. Grade: 5.0 sq.ft. 24"(h)x 20"(w)minimum 44"maximum height above door Residential: Check paperwork compliance and Inspection checklist-Okay Driveway length: 300'or more-12'width required I500'or more turnaround required Foundation insulation to basement floor Damp proofing/Waterproofing materials on plans Foundation drainage on plans,If required 6"drop in 10'Exterior grade Framing cross section for each roof line,Vertical fire stopping every 10'where required Ice&Snow Shield-24"inside exterior wall/24"inside knee walls Platforms at exterior doors Stairway headroom 6'8";all stairs 36"width Stair Run and Rise Winder Run and Rise Spiral not allowed from 2nd story Smoke Detectors-battery backup and proper location interconnected Bathroom fixtures-proper clearance Hall width-36"width Handralls more than four risers on open sides Railing&Guards>30"/Basement stairs included/Closed risers more than 4"in height Safety glazing notes for required areas Garage fire separation Garage floor sloped Attic access Roo - 2"x 30"/Crawl spaces 18"x 24"access ra'rbon Monoxii0detector outside lowest sleeping area,on every level &interconnected within 15'of e 1 g area Soil Test results,if required Septic to we r water line separation All paperwork signed Note on plans energy-saving light bulbs ower door test agency paperwork Floodplain Permit Required-Check Map Residential Plan Review-1&2 Family Dwellings 10-2-2014 REScheck Software Version 4.6.2 Compliance Certificate Project Johnson Residence Energy Code: 2010 New York Energy Conservation Location: Warren County, New York Construction Type: Single-family Project Type: New Construction 252.-1-36.6 RC-000436-2016 Conditioned Floor Area: 6,$87 ft2 Johnson Jamie Glazing Area 16% Climate Zone: 6 (7635 HDD) 268 Lockhart Mountain Road Permit Date: SFD w/2 FPS 4070 s.f. Permit Number: Construction Site: Owner/Agent: Designer/@erftre*6*fi6_ 268 Lockhart Mountain Road Mr.Joseph A Paone Lake George, NY 12845 Paone Architecture 547 Route 9P Saratoga Springs, NY 12866 518-580-0017 Compliance: Passes using LIA trade-off Compliance: 4.6%Batter Than Code Maximum UA: 647 Your UA: 617 The%better or worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Basement Wall: Solid Concrete or Masonry 2,168 13.0 5.0 0.041 89 Wall height: 8.8' Depth below grade: 8.8' Insulation depth: 8.8' Wall:Wood Frame, 16" D.C. 4,222 21.0 0.0 0.057 196 Window B: Wood Frame:Double Pane with Low-E 7 0.290 2 Window B: Wood Frame:Double Pane with Low-E 7 0.290 2 Window D:Wood Frame:Double Pane with Low-E 14 0.290 4 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E JUL )7 2016 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E �_r.{` Oa=S -- 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Project Title:Johnson Residence Report date: 07/05/16 Data filename: C:1PiPAProjectsuohnson\RESCheck\RESCheck.rck Page 1 of 8 Gross Area Cavity Cont. Perimeter Window E: Wood Frame0ouble Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window E: Wood Frame0ouble Pane with Low-E 10 0.290 3 Window E: Wood Frame0ouble Pane with Law-E 10 0.290 3 Window E: Wood Frame:Double Pane with Law-E 10 0.290 3 Window E: Wood Frame:Double Pane with Low-E 10 0.290 3 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Law-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F:Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F:Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Law-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window F: Wood Frame:Double Pane with Low-E 4 0.290 1 Window J: Wood Frame:Double Pane with Low-E 21 0.290 6 Window J: Wood Frame:Double Pane with Low-E 21 0.290 6 Window K: Wood Frame:Double Pane with Law-E 7 0.290 2 Window K: Wood Frame:Double Pane with Law-E 7 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L:Wood Frame:Double Pane with Low-E 6 0.290 2 Project Title:Johnson Residence Report date: 07/05/16 Data filename: C:1P1PAProjectsUohnson\RESCheck\RESCheck.rck Page 2 of 8 Gross Area Cavity Cont. Perimeter Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L• Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window L: Wood Frame:Double Pane with Low-E 6 0.290 2 Window M: Wood Frame:Double Pane with Low-E 9 0.290 3 Window M:Wood Frame:Double Pane with Low-E 9 0.290 3 Window N: Wood Frame:Double Pane with Low-E 9 0.290 3 Window N: Wood Frame:Double Pane with Low-E 9 0.290 3 Window P: Wood Frame:Double Pane with Low-E 20 0.270 5 Window Q: Wood Frame:Double Pane with Low-E 12 0.290 3 Door-Front: Solid 28 0.500 14 Door D1: Wood Frame:Double Pane with Low-E 125 0.300 38 Door D2: Wood Frame:Double Pane with Low-E 94 0.300 28 Door D3: Wood Frame:Double Pane with Low-E 47 0.300 14 Wall-Cuppola: Wood Frame, 16" o.c. 540 13.0 8.0 0.048 26 Ceiling: Raised or Energy Truss 2,817 22.0 16.0 0.025 70 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4. comply with the mandatory requirements listed in the REScheU spection hecklist. ,,.�- �c��'trt G. g- of• !6 Names Signa ure Date Project Title:Johnson Residence Report date: 07/05/16 Data filename: C:\P\PAProjectsvohnson\RESCheck\RESCheck.rck Page 3 of 8 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.2 Construction drawings and ❑Complies [PR1)1 documentation sufficiently ❑Does Not demonstrates energy code compliance for the building ❑Not Observable envelope. ❑Not Applicable 103.2, Construction drawings and ❑Complies 403.7 documentation sufficiently ❑Does Not [PR3)1 demonstrates energy code d compliance for lighting and ❑Nat Observable mechanical systems. Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Beating: ❑Complies [PR2]2 sized per ACCA Manual S based Btu/hr Btulhr ❑Does Not on loads per ACCA Manual j or Cooling: Cooling: ❑Not Observable other approved methods. Btu/hr Btu/hr ❑Not Applicable Additional CommentslAssumptions. 1 High Impact (Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Johnson Residence Report date: 07/05/16 Data filename: C:1PlPAProjects�ohnsonlRESCheck\RESCheck.rck Page 4 of 8 Section # Foundation Inspection complies? Comments/Assumptions & Iteq.1D 303.2.1 Exposed foundation Insulation _ ❑Complies [FO11]2 protection. ❑Does Not ❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: J High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Johnson Residence Report date: 07/05/16 Data filename: C:1PlPAProjects' ohnson\RESCheck\RESCheck.rck Page 5 of 8 Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.4.4 Fenestration that is not site built ❑Complies [FR2011 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR1612 sealed at housing/interior finish ❑Does Not and labeled to indicate&It;= 2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]I air handlers,filter boxes,and ❑Does Not ty building cavities used as return ducts are sealed. ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not 4A ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not q� below 55 QF are insulated to R-3. _ ©Not Observable ❑Not Applicable 403.4 Circulating service hot water R- R- ❑Complies [FR18]2 pipes are insulated to R-2. ❑Does Not y [-]Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. I j]Not Observable ❑Not Applicable Additional Comments/Assumptions: High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:Johnson Residence Report date: 07/05/15 Data filename: C:1P1PAProjects�ohnson\RESCheckl,RESCheck.rck Page 6 of 8 Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation labeled or ❑Complies [IN13]2 installed R-values provided. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions; 1 High Impact(Tier 1) 2 Medium Impact(Ter 2) 3 Low Impact(Tier 3) Project Title:Johnson Residence Report date: 07/015115 Data filename: C:IPIPAProjects�ohnsonlRESCheck\RESCheck.rck Page 7 of 8 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.4.2, Building envelope tightness ACH 50 = ACH 50 = ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [FI17]1 of&It;7 ACH at 50 Pa.This t� requirement may instead be met ❑Not Observable via visual inspection, in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post- cfm cfm ❑Complies [FI411 construction with maximum ❑Does Not leakage of B cfm to outdoors, or 12 cfm across systems. For ❑Not Observable rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection, with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats ❑Complies [F19]2 installed on forced air furnaces. ❑Does Not + [[Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. ❑Does Not ❑Not Observable ❑Nat Applicable 403.4 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not []Not Observable ❑Nat Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not +� equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact{Tier 3) Project Title:Johnson Residence Report date: 07105/16 Data filename: C:1P1PAProjectsVohnson\RESCheck\RESCheck.rck Page 8 of 8 I �f o �r I p i `.6 KHA UN_ RT M0 TAIN R n N 2_43 1271.73' N 32°12'31"W r� 37D 25.05 -_ O 78.24' SAO n N O O rn z < rn p 0 . n D ate✓ 67 PO �O�O� Fj ?$ _ -- CO •h J O p FTI 1 - co wQ cfl N z- y 4 O Z i N N UT CA N _ Q u r iv co m 0 o z mo mp cncoC/) 01 � � r O CD 01 -n v T rn � C T (D O O O C M y T Cl) f I 7& sono _7 i f%f j` r` f f l ff ✓ 70 S Qu' u'- i 0 6 ?,D- +, m ` nno /2 zzo � av, 0 % � ozm � mo T < Z � = mti M M fJ a' C, m eco % 8 m m r 0 Y < / N ® 1 - u -rj ti II � v i < I- � � r- ti ti � r m -Tl Z m i z z m0zo m m o m PERNMT PLOT PLAN 252.-1-36.6 RC-000436-2016 I HAVE PERSONALLY MEASURED THE DISTANCE Johnson, Jamie !=CJI\,-1 TPF- ��nl'ERTY LIMES TO THE __ �,�SIG p( } 268 Lockhart Mountain Road Ru D�1211 '7(s) SF® w/2 Ps 4070 s.f. - 07 201 rk� 4 siE � � v � �"...Wil't�:.;l�v•_: _ ._.�.,...�.aa.+a+.n�.` '.'"" -- ALTERATION OR TON TO A SURVEY Lam• - MAP BEARING EARI NIS CENSER LAND SURVEIYORS SEAL 5 A - /� m Rr VIOLATION OF SECTION 7208,SUB-DIVISION 2.OF THE Map of a Survey made for - z cc - ® W NEW YORK STATE EDUCATION LAW.' - - O ` /t,/� o MARKED COPIES FROM THE ORIGINAL OF THIS SURVEY - ' 0 =RI V LI a CS MARKED W9TH AN ORIGINAL OF THE LAND SURVEYORS - - = m g rF Ste -ves SEAL SHALL BE CONSIDERED TO BE VAUD TRUE COPIES- z - 4L O _ _ 'CERTIFICATIONS INDICATED HEREON SIGNIFY,THAT - N C Q_ Cr -, THIS SURVEY WAS PREPARED IN ACCOROSURVEY R TID - Jamie Johnson 3 05/03/16 Proposed House Updated N Q r ® T/T fy� C EXISING CODE OF PRACTICE FOR LANG SURVEYORS ADOPTED _ - , BY THE NEW YORK STATE OCIATION OF Z p H"'' h Land S u ry e J o i s LAND SURVEYORS.SAID CERTIFICATIONS SHALL RUN ONLY 2 03/10 16 Proposed House Updated - _ TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND / p p -j ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL - AGENCY AND LENDING INSTITUTION LISTED HEREON,AND 169 Haviland Road Queensbury? New York 12804 Town of Queensbury, Warren County, New York 1 01108116 Proposed House G� ® Queensbury, TO THE ASSIGNEES OF THE TENDING INSTITUTION.' 18 792-8474 New York Lic. No. 50135 �5 ) _ N0. DATE DESCRIPTION 252-1-36.6 I -