Loading...
2012-145 TOWN OF QUEENSBURY Iwo742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development -Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120145 Date Issued: Thursday, May 31, 2012 This is to certify that work requested to be done as shown by Permit Number P20120145 has been completed. Location: 12 SUNSET Dr Tax Map Number: 523400-295-019-0002-035-000-0000 Owner: ROBERT MEDVE Applicant: ROBERT MEDVE This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property ( LE)owner of the responsibility for compliance with Site Plan,Variance, or other issues and conditions as a result of approvals by the Planning BoardDirector of Building&Code ' orce* nt or Zoning Board of Appeals. An TOWN OF QUEENSBURY FOO 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: P20120145 Application Number: A20120145 Tax Map No: 523400-295-019-0002-035-000-0000 Permission is hereby granted to: ROBERT MEDVE For property located at: 12 SUNSET Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Buildin• Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ROBERT MEDVE Residential Alteration $70,000.00 12 SUNSET Dr Total Value QUEENSBURY,NY 12804 $7o,aoo.00 Contractor or Builder's Name /Address Electrical Inspection Agency ALL PRO CONSTRUCTION 793-5311 1352 SARATOGA Rd GANSEVOORT,NY 12831-0000 Plans&Specifications 2012-145 1155 interior alteration/fire damage repair $173.25 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,April 10, 2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Tuesday,April 10,2012 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement i 29(64 T IIMJ-3.S OFFICE USE ONLY `� �/ r "�""�"i"�OOlO IM _ PERMIT NO. IO(' / /5 itECEOVE1-1 FEES: PERMIT/7ECREATION ENGINEERING (If applicable) i ' O �v PRRMIT AL STRUCTURE: APPLICATION FOR ZONING flP/3V� / •j�yG A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER:ALL PRO ReSfo( Ak1oi OWNER: Robert NJCu(Ve- ADDRESS:)3S1 Route q' GcofSeLyon' i /Y �An I ADDRESS: IISuk.Set Dr. Queehst o'y 11, l XGA PHONE NOS. (SNO793 —5311 5 _V-L PHONE NOS. CS10) 931— 157q- Oa We CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: Lk SUi.cGt Dr. Ooee c,iic4 M-, J�({0� ,/�d�� HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION/ APPROVAL? A YES --Zi NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: A, a',/‘ t A sai -,4./ i ‘,1'63"--d Si-- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: eR CHECK ALL THAT z APPLY TO YOUR z 0 ce 0d o I- W LL 1 W O `L LLLL W Q d = = w o F- 2 I- O C� z z Q a rco iqm J 16 L: 0OLL pc • SINGLE FAMILY /` 4 /cc }, �y idss ( TWO-FAMILY _ ( " IY MULTI-FAMILY 20 Pk (NO of UNITS ) V TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(12,3) OTHER Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 70 060 FUEL TYPE 60. S HEAT TYPE: GoLS/Yd(([ot'HO �WMANY FIREPLACE(S): / AND/OR WOODSTOVES(S): D ZONING CATEGORY:Rai-di +iu ARE THERE WETLANDS ON THIS SITE? Aid IS THIS A HISTORIC SITE? /`/U PROPOSED USE OF BUILDING OR ADDITION:: I{aOYIS+cVCfOh .V'fah-r -Crc da,W+&9G• P/ou,S will be Sevi-t cute- early ,,ej- t�ifttle /v , ARE THERE STRUCTURES NOT SHOWN ON PLcIT PLAN? o ARE THERE EASEMENTS ON PROPERTY? NO *Please complete a separate Application for"Fuel Burning Appliances&Chimneys'available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804 Queensbury Building & Code Enforcement - Residential Final spection � • 2 m/pm Office No. (518)761-8256 Arrive: arUp Depart • m/pm Date Inspection request received: S 210) �- Inspector's Initials: 7 / NOMATION: c)I9 PERMIT#: ' ' TYPE OF STRUCTURE: el �� 1�� DATE: 5/?Va0A� Comments: Yes No N/A 1°C 4" Building Number Address visible from road ///JJJ Chimney Height/°B"Vent/Direct Vent Location o Fresh Air Intake /rekC., 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors / Handrail 4 or more risers / t (te. 7ia y` Guards at stairs,decks,patios more than 30 inches above grade ruck / Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches . Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors I main entrance 36 inches Bathroom/Kitchen watertight _ Safety glazing/Window in :I.:" .. - glazing (7/ Interior Smoke Detectors Carbon Monoxide Detect. Every level: Eve room: Outside Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly I Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inches • Garage Floor Pitched Garage fireproofing 1%hour fire door/door loser Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/01 Temporary/Permanent] L:1Building&Codes Forms1Buiiding&CodesMnspection Fomis Residential Final Inspection Form_revised 100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 Y u s sda Lt a--y Queensbury Building & Code Enforcement - Residential FinaTlnspecti n Office No. (518) 761-8256 Arrive: am/pm Depart:7,�S am/pm Date Inspection request received: 57$,6fllc& Inspector's Initials: V NAME: Rth)p(s} Mea v e PERMIT / ,,Z—/y S LOCATION: i2 S tt n &EA- O r DATE: 5 ate/ TYPE OF STRUCTURE: Tn-ft tnr roV ?r 7n Comments: Yes No WA 4" Building Number Address visible from road - den € y©Q p 667 Chimney Height/'B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches o nQ�-� e Roof Complete/Exterior Finish Complete p�u�cj Platform at all exterior doors B J l 0 P 1] Handrail 4 or more risers Cka w , Guards at stairs,decks,patios more than 30 inches above grade � Guard at stairwell at 34 inches or moreaxt � Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior /trim/doors/main entrance 36 inches S_ Bathroom m/KitchenC,t�_< watertight a`^7`- Safel lazin /Window in st�iwvelbo Interior Smoke Detectors/ ar - onoxide Detect Every level: Ev om: Outside every bedroom area: _ Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'''A hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0[Temporary/Permanent] L:tBuilding&Codes Fonns1BuiIding&Codesllnspek on Forns\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/27/10,Revised 04/13/11 Rough Plumbing I Insulation Inspection Report r Office No. (518) 781-8258 Date Inspection request received: LI/4 7- Queensbury Building &Code Enforcement Arrive: am/pm Depart:22ie am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:�^t_gVt�Ti1 • NAME: (11 c-D VPERMIT #: LOCATION: )-1_, Su•`_Svi b@- • INSPECT ON: 67 2— TYPE TYPE OF STRUCTURE: c V N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 IA inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 5 56 P.S.i for 15 minutes ) nsulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Q- ` e.3 eyc-v\- Rough Plumbing Insulation Reportreviseii Nov 17 2003, revised February 15,2005, revised January 7, 2008 Framing Firesto/ nJ 3 _1 piling Inspection Report 3 Office No. (518)761.8256 Date Inspection request received: Y/3-/z Queensbury Building&Code Enforcement Arrive: am/pmDepart1V 4c� 11)m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: / NAME: INAGc . U PERMIT* 447,1 LOCATION: f s U f Or INSPECT ON: TYPE OF STRUCTURE: R43 4fr see NiAv, .,4raming —�� COMMENTS: Attic Access 22'x30'minimum /06 e-r 4- tAshdat Jail Studs/Headers N&t3 RDS' (fl. -(�-, Bracing/Bridging Joist hangefs Jack Posts/Main Beams Exterior sheeting nailed properly MSL C2-‘7o% 12'O.C. Headman 6 ft. 8 in. -Tr2--1/4-157Y( Stained's 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 ''A(w) 16 gauge (8) 16D nave east side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft. or less on center f#and water shield 24 inches from wall V Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 14 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above I below grade 5.0 sf grade L:\Buildhg&Codes Fonns-0LD1Buf dhg&CodesVnspedion Fams\Fmdig Fhestappinp Inspection Repoit.doc Revised January 7,2008 Framing / Firestopping Inspecti' - R Sin rt Office No. (518)761-8256 Date Inspection -. Queensbury Building&Code Enforcement Arrive:. 'iT y: •- a 742 Bay Road, Queensbury, NY 12804 Inspector's n' NAME: M ED\1 EC (RMITt LOCATION: 1 Z ,A)v�h E O P1 \1e. PECT ON: • • Z TYPE OF STRUCTURE: .A F n — F‘ RE n At-1 r` GE_ Y " COMMENTS: Framing Attic Access 22'x30- minimum Jack Studs/Headers Bracing/Bridging \'J E M O RF a-7-1\�t�� Joist hasts/ \_ � \ �A�`�-\-eoa3`j Tc� Jackck Posts/Whin Beams � Exterior sheeting nailed property E JJ 6 hJ - 5 )cd'F -T ev 12°O.C. 9�N6QNM'7 \ t� �Q-� L7S ? Pr UF- Headroom 6 ft. 8 in. Exterionvells 36 r Deck Braaci�more = 6\7)o,V- F :,� S S� Wo�1 V Headroom 6 ft. 8 in. j� �� v� �T\ (� Notches/Holes/Bearing Walls F 9- \LEQ \?` Nt7 Metal Strapping for Notches Top Plate 1 ''A(w) 16 gauge (8) 16D nava sacs side Draft stopping 1,000 sq.ft floor trusses Anchor Botts 6 R or lesson center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Flrestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilinglwa0 Windows Habitable Space/Bedrooms 24 in. (H) 20 in. ON) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms OLDIBuilding&Codeevnspedion FonMFionkg Firestopping inspection Repmldoc Revised Jemmy r,zoos I E b) ..IECEOVE MiTek APR 0 2 2012 D 7pWN F U {rdu tries, Inc. BUILDING& (J9OD df%e East B a pa, 15 Re: 120963 Smart Level Const The truss drawing(s)referenced below have been prepared by Mitek Industries,Inc. under my direct supervision based on the parameters provided by Saratoga Lumber Traders, Inc.. Pages or sheets covered by this seal: T4333286 thru T4333288 My license renewal date for the state of New York is June 30,2014. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. (tpF NEW 4 ' A,/1/4 t, O * �� 2 +. zr- il aritr41 I --ad in O >7357!' AROFESStONP� March 28,2012 Albani,Thomas The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSI/TPI 1 Sec.2.