2012-174 0111111K TOWN OF QUEENSBURY
re" 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20120174 Date Issued: Monday, July 02, 2012
This is to certify that work requested to be done as shown by Permit Number P20120174
has been completed.
Location: 352 GLEN LAKE Rd
Tax Map Number: 523400-289-009-0001-069-000-0000
Owner: ROBERT NAPOLI
Applicant: ROBERT NAPOLI
This structure may be occupied as a:
Residential Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
F0104 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
F
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20120174 Application Number: a20120174
Tax Map No: 523400-289-009-0001-069-000-0000
Permission is hereby granted to: ROBERT NAPOLI
For property located at: 352 GLEN LAKE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ROBERT NAPOLI Residential Alteration $14,000.00
BONNIE NAPOLI Total Value
13 CHESTNUT Rd $14,000.00
LAKE GEORGE NY 12845-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2012-174
Res. Alteration 1st Flr 730.85 sf& Porch 234.40 sf
$144.79 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,April 20, 2013
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o Queen ury; rid y, •�' I,2012
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
a:0 •`1 I- 69 OFFICE USE ONLY
TAX MAP Nat
_._.-....__._PERMIT NO.__I__ .
FEES: PERMIT1yy ? RECREATIONENGINEERING __ [ill
. - 1aT 1 2012
(If applicable) i :
PRINCIPAL STRUCTURE: APPLICATION FO
PERMIT R ZONING APPROVAL 8, BUILDING
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW
BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: :Ig bf N j4 f-4 1 r'
OWNER: �--
�� 4 �°Ir Ai��/`'"', � r _
ADDRESS:
/�'�f ADDRESS: 1 r 4 . it 14 7A',;.l ,
PHONE NOS. 7 1 ‘' (4 Ql '] PHONE NOS. ) rf (;o r.,
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE:
PHONE: 7 96 2 v 4 11
LOCATION OF PROPERTY: a r (.. a
HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? U YES ENO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
rr APPLY TO YOUR
PROJECT O cL
O 0 I-
H O cnco W LL 0)
p W �� J � cc J O0 }_ W
W F U_ W Q d = 2
-J y C o = F C7 CJ
Z_—Q < - r� cv � OLL � � W Wz
a cu
SINGLE FAMILYI/ Sic1 '/ 1/(1 q6. S 3
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE --`— —_
BUSINESS OFFICE
RETAIL-
MERCANTILE '
FACTORY OR —
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER •
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: / yi Q Q a r ' FUEL TYPE: 1 r L.
HEAT TYPE:r IC t x'! 40 i 'HOW MANY FIREPLACE(S): 0 AND / OR WOODSTOVES(S): /)p
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? /L., 0
IS THIS A HISTORIC SITE? __I, s 0
PROPOSED USE OF BUILDING OR ADDITION: k e..sci .) ?_., i...
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? A) 0
ARE THERE EASEMENTS ON PROPERTY? .) 0
1:,_gg&Chimneys' =1:'c,flfl!`•ia;in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit I certify that the application. plans, and supporting materials arena .true and
complete statement/description of the work proposed, that all work be performed in
accordance with the NY State Bui,ding Codes, local building laws and ordinances, and in
conformance v'itn local zoning regulations. I acknowledge that prior to occupying the
facilities proposed. I or my agents will obtain a certificate of occupancy. I also understand
that I.v.e are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above
Signed �'2 ,
r 7T�
Director ar Bulgy & Coces: 761-82'3;:i ales i` ..s regarding Building Permits construction codes
or septic systems:
Zoning Administrator 761-8218 ,'cr questions reoarcing required permits. the oeymit process.
application requirements or to scneci,.i e an appointment)
Permission is hereb'. grant ed to the above This application proposed action described
Applicant to erect or alte" the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Tor,n of Queensbury
Application:
( 1
1p,
BUILD ,G : ZONING APPROVAL
U w •
DAI DATE
OUESTioNs? CALL 761-8256 OR EMAIL
codes e,queensbury.net
l
Office Use On!,,
\- VISIT OUR YlE6srTE FOR MORE INFORMATION
Operating Permit iss,ec e ,e �.1vv,.queensbury.n2t �-
Occupancy Type: _ Construction Classification
Assembly Occuaanc;. Li:.: - ______ Spec:al Conditions.
CJeens:,... ..i-.. D :rmert `�:: `e - Ba, O ee-s:),.,--•
�ri•dc,xg --1-
Queensbury Building & Code Enforcement - Residential-Final Inspection
1
Office No. (518) 761-8256 Arrive: am/pry Depart:7 , O am/pm
Date Inspection request received: (;7 r4 7-1 A Inspector's Initials:
NAME: RobNr+ kap-, II' PERMIT#: - I
LOCATION: 3 5X1 QR,l DATE: Le --0
TYPE OF STRUCTURE: n�S/c✓d
Comments:
Yes/No NIA
4" Building Number Address visible from road V
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Win4o�w in stairwells safety gl ng /
Interior Smoke Dey�ctors/Carbon M oxideetectors �//
Every level: �1// Eve Bedroo : V
Outside every bedroom ea:
Inter Connected: Battery backup: i
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum V2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
_Garage fireproofing 1%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure /
Final Electrical; Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles t
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent] t.:t4:„.),
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
Frit ` (3-0Rou h Plumbing I Insulation Ins etion
Report
Office No. (518) 761-8256 Date Inspection request received: of
Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: tic}po )L PERMIT #: /6)-1).V
LOCATION: v 360 ,. .;
/ Firestopping a
Framing pping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: ' . e /,)_
Queensbury Building &Code Enforcement Arrive: am/pm Depart _ :m/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:0 A
•
NAME: N/ PERMIT#: t /c) l
LOCATION: /.L Ab._4/ INSPECT ON: /fIT& 21, y4,d,
,)-
1
TYPE OF STRUCTURE: � / ,
Y/( N N/A
gaming — j� COMMENT$:
Attic Access 22' x 30'1 minimum
Jack Studs/ Headers
Bracing / Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in. •
Notches/Holes I Bearing Walls
Metal Strapping for Notches Top Plate
1 'A(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '6 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/ Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\6uilding&Codes Forms-OLD\Building&Codes\Inspec ion FormsTraming Firestopping Inspection Report.doc Revised January 7,2008
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p v.)Depart2:14tri/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: !v PERMIT#: 2 3 V .'' V.-A--
LOCATION: . RiZvv4.43 INSPECT ON: 4 V0--e„,_
TYPE OF STRUCTURE: 11"-
Comments
Y N N/A
Footings
7--tr
Piers W7-42*�
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM