2012-360 TOWN OF QUEENSBURY
742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201
�_ Q ry,
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20120360 Date Issued: Wednesday, August 28, 2013
This is to certify that work requested to be done as shown by Permit Number P20120360
has been completed.
Location: 15 LESTER Dr
Tax Map Number: 523400-301-013-0001-018-000-0000
Owner: JAMES & CYNTHIA STONER
Applicant: JAMES & CYNTHIA STONER
This structure may be occupied as a:
Deck By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property (.'" J
owner of the responsibility for compliance with Site Plan, Variance, or f/
other issues and conditions as a result of approvals by the Planning Board Director of Building& Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
F 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20120360 Application Number: A20120360
Tax Map No: 523400-301-013-0001-018-000-0000
Permission is hereby granted to: JAMES &CYNTHIA STONER
For property located at: 15 LESTER Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JAMES &CYNTHIA STONER Deck $3,500.00
15 LESTER Dr Total value
QUEENSBURY,NY 12804 $3,500.00
Contractor or Builder's Name/Address Electrical Inspection Agency
WILSON HOME SERVICES
MILTON WILSON 859-9944
1961 COUNTY ROUTE 31
GRANVILLE NY 12832-0000
Plans&Specifications
2012-360
Deck 153 sq ft
$50.00 PERMIT FEE PMD-THIS PERMIT EXPIRES: Wednesday,July 31, 2013
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Quecnsbury before the expiration date.)
Dated at the Town ensbu Tu ' a, July 31, 2012
SIGNED BY Queensbury.
for the Town of! � Q
Director of Building&Code Enfo cement
_ 4.
r r
413-'14 OFFICE USE ONLY
RI
TAX MANO. i PERMIT NO. ' p) f,�6p
•
FEE PAID - " , BLDG.&CODES APPROVAL i JUL. 2 6 2012
ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure (house) to include, but not limited to:
garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-
Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF.A VA I
PERMIT, NO INSPECTIONS„I (nIWILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT.YY1VJI t4”
OWNER: J tvA, (JAAI& �iyl l/ �+ ���� INSTALLER/BUILDER: �i IS-0d 1 IC cir[)l(e j� f y
ADDRESS: 15 Le,'tt'&,(�DJr; tic ADDRESS:1 1 )1 C if (47-e. ,
PHONE NOS. / y} Q J t' PHONE NOS. 1 t y
LOCATION OF PROPERTY: SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: DZ-C.It t6.A of l jc,S<_
ESTIMATED COST OF CONSTRUCTION: $13-00.CC ANY OTHER ACCESSORY STRUCTURES ON PROPERTY?
IF YES,PLEASE LIST: I- + L
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: M 1 I.t IA I 1 St4 PHONE: Sgt - i 7 7(/
y
sr Ho PROPOSED
PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT
SQ.FT. SQ.FT. SQ.FT. FT.&IN.
OPEN PORCH
DECK I 5-3 15-3 10'
3 SEASON,COVERED OR ENCLOSED PORCH*
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS: ) .
OTHER ACCESSORY STRUCTURE:
*CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN
THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained in the application, together with the plans and
specifications submitted, are a true and complete statement of all proposed work to be done on the described
premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to
the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the
owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of
Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-
Built Survey by a licensed surveyor, drawn to scale showing actual location of all new construction.
I have read and agree to the above.
,//77� I,►n/ QUESTIONS ? CALL 761-8256 OR EMAIL
Signed ied'�'"' (,&J J2 .i/ Dated: 7/21// 2_ codes(u�queensbury.net
1 (1 VISIT OUR WEBSITE FOR MORE INFORMATION
Name/Title(Printed) /4I J.t���l `�•' �L'] I"��� www.queensbury.net
—
Queensbury Building & Code Enforcement - Residential Final inspection
Office No. (518) 761-8256 Arrive: am/pm Depart:L(- R am/pm
P
Date Inspection request received: Inspector's Initials: 64,f,r)
NAME: PERMIT#: -3("D
LOCATION: U-Srert-_ t72 DATE:
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers /
Guards at stairs,decks,patios more than 30 inches above grade ti/
Guard at stairwell at 34 inches or more
Guard at deck, porches 36 inches or more ,
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly I Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door loser
Gas Logs in Sealed or Glass Enclosure
Final Electrical; Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent]
L:1Building&Codes Forms1Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6126/08; Revised 12122/10,Revised 04/13/11
Queensbury Building & Code Enforcement - Residential Final Inspection f 3
Office No. (518) 761-8256 Arrive: am/pmD ca-m/pm
art: <
Date Inspection request received: 711��l 3 Inspector's Initials: /1
NAME: 5+D 1/1 r- -- (r)1 4r Ali LI-W i/Svc PERMIT#:
LOCATION: l C�� c U t�,.�� DATE: r i. 3
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
A.17// Cr) 6 t.b
Platform at all exterior doors
Handrail 4 or more risers 1/.
Guards at stairs,decks, patios more than 30 inches above grade ,� �'
Guard at stairwell at 34 inches or more Vey�3" o 5
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant02>
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy I trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area 's ra-
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window c7-o
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler R
Relief Valve(s)installed/Heat Trap/Water Temp 110 ,-
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing I'/,hour fire door/door closer k t1
Gas Logs in Sealed or Glass Enclosure
Final Electrical; Energy Saving Light Bulbs 50% \ .�
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker 7C 1 2.(5-"?
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
CROSS-SECTION
CUSTOMER -- MILT / _3 /
DATE 07/24/12 REF Deck12206 6
r4
- j ;. .
,.
it
1 . ,
'c„,/,..,,, , G TOWN OF QUEENSBURY
liii
4."'-'Oil Y■,�,■•r7 =:,.. .,,i „.-.:..---,_ ;-,I.
k{, 'hit _! _ 1�� .�,� .4, Date:. iif/
ups,,,\irk■I r,r rr■r•.r.■ .r i
.r.. _ r'i.`I li II . ! �I '®' '�:+sr
r■i r1i r i ' o■;q r i '.#i 1 1111 .i
.* .. �ert �
�zrlr,■'r r r I ,.,a 4,5014414,4/
tIP-7 +:ttlii ■,r,ir o;�ii1�4 .'. ° TOWN OFQUEENSBURY
e esBUILDING DE AR` :,TENT
� 664J �.1r-41P'' ,/ �` '1 11,;11/, Based on ourlimitedsxamin?tan compliance
` -.I-14 Q : I i:W1 ~. �� ur comments shall Heti ne construed as
' *ro. ,( 11 r�,. v with o
y y�` � �,► 44 •
indicatin the plans d spec`cations are in
' � Y;� full compliance with the Uu4ing Codes of
_i � '���' New York State.
D � 1
14.1<� ,
t ro tir
i ..(
”,
4
.,
,,, .., „ .: . _ .
. , 111'.-0,
t.„,„,, .,,,,,,,
,, , ,.,
ii 1\k.E. C°PN.
14
7 .. 40 i i, : I 't'
fZ .;, ,.!.,y. ;.
—i' izi,,......._- ./II',al
TA.,...,], „
� I
/ STORE NAME
123 STREET RD.
CITY. ST
18001 555 1212
B) 14'11 "
B) 14' 11 "
B) 14' 11 "
B) 14' 11 "
B) 14' 11 "
B) 14'11 "
B) 14'11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 ' 11 "
A) 11 ' 11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 '11 "
A) 11 ' 11 "
A) 11 '11 "
A) 11 '11 "
Plank Layout Store Name
MILT 123 Street Rd.
07/24/12
I Ref:Deck12206 City, ST
Scale: 1/2"= 1' (800)555 1212
2' 5 1/2'
A
7' 8"
2' 1/2"
BEAM BEAM POST POST
LABEL LENGTH COUNT SPACING
A 2' II 3/4" 2 2' 6 1/4"
B II' IO 1/2" 3 5' 2 1/2"
Post spacing is measured center-to-center.
fl pth of cnn footers --- 48"
Beam Layout Store Name
MILT 123 Street Rd.
07/24/12
Ref:Deck12206 City,ST
Scale:3/8"= 1' (800)555 1212
H
1
A A A A A A A A F ,
L
( II C
EK
II II II
DI
J
LABEL LENGTH BEVELS LABEL LENGTH BEVELS
A Joist(8) 11'8 1/4' G rim 2' 8 1/4'
B Joist(3) 2'8 1/4' H rim 14' 10 1/2'
C fascia 12' 1)0 2)46 I cap 5'5'
C rim 11'8 1/4' I section 5'7 1/4'
D fascia 12' 1)45 2)45 J cap 5'4 1/2'
D rim 11' 10 1/2' J section 5'7'
E fascia 9'3/4' 1)45 2)45 K cap 4'2 112'
E rim 9' K section 4' 5'
F fascia 3'3/4' 1)45 2)46 L cap 3 3/4'
F rim 3' M cap 2' 1 1/4'
G fascia 3' 1)45 2)0 M section 2' 3 3/4'
Cut List Store Name
MILT 123 Street Rd.
07/24/12
Ref:Deck12206 City,ST
Scale: 1/4"= (800)555 1212
STRESS ANALYSIS
CUSTOMER: MILT
DATE: 07/24/12 DESIGN: DECK12206 REF:
SALESMAN # LEONARD
MEMBER STRESS FACTOR COMPOSITE
TYPE SIZE FACTOR LOAD LOAD
JOISTS 2X8 DEFLECTION 116 PSF
16" BENDING 126 PSF
SHEAR 118 PSF
COMPRESSION 201 PSF 116 PSF
BEAMS 2-2X10 DEFLECTION 529 PSF
BENDING 199 PSF
SHEAR 118 PSF
COMPRESSION 282 PSF 118 PSF
BOLTS 1/2" SHEAR 3925 PSF 3925 PSF
POSTS 6X6 STABILITY 1143 PSF 1143 PSF
TOTAL LOAD 116 PSF
DEAD LOAD 10 PSF
LIVE LOAD 106 PSF
STRINGERS 2X12 DEFLECTION 56 PSF
BENDING 133 PSF
SHEAR 277 PSF
COMPRESSION 1234 PSF
TOTAL LOAD 56 PSF
DEAD LOAD 10 PSF
LIVE LOAD 46 PSF
A 0 111 IS
"IV It 411 A A° Asa
lidlink A : °A 1 Cill I
relaligaDAR • : I A
L6RpYDON
ii 4 eV . . .
-A, \_
i� O ` AMN
AA
1 A \li liii A°5 : : A A AA A. A. 1
RD
. "X all IP
•
LES TER DRIVE jj
00 �
S$252'00"E r
100;00' 1
I � p
� a
h�E
000
Lo
Z a. LO
Io k"-
0
" -0 sq.9t.
0.34 acres /
P.F. 100. o'
N82'12'00"W ,.P.F
71
ryry °�i
Fly
"°°° "
`° — Map of a Survey made for
URYaICRf o A ISA -
•drlaa L a me
Yr R nq5 SURIEY
E
VMD MU SW
rNw `�_ WILLIAM S. & BEVERLY HERMANS.
Ld1 SIOIIIFY THAT
1000PVIIMU WM 111E
WD NTfYd16 P°CPllD '
ON°E PRdf89W11 ^
1Tid19
M SPREPAR A pl.Y
EUR4Y 5 PRED,IlD
W WIY�°CrtRN4piTAL
U=NEREM.WW Town of Queensbury, Warren County, New York
Rn Wsxnnny
NO. DATE DESCRIPTION