2012-384 rTOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20120384 Date Issued: Monday, October 29, 2012
This is to certify that work requested to be done as shown by Permit Number P20120384
has been completed.
Location: 183 QUAKER Rd
Tax Map Number: 523400-296-019-0001-043-000-0000
Owner: FLEET NATIONAL BANK
Applicant: BANK OF AMERICA
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property1 -
f�
owner of the responsibility for compliance with Site Plan, Variance, or /d . f
other issues and conditions as a result of approvals bythe PlanningBoard
pp Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20120384 Application Number: A20120384
Tax Map No: 523400-296-019-0001-043-000-0000
Permission is hereby granted to: BANK OF AMERICA
For property located at: 183 QUAKER Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: FLEET NATIONAL BANK Commercial Alteration $25,000.00
C/O BANK OF AMERICAN CORP R Total Value $25,000.00
NCI-001-03-81
101 N TRYON St
CHARLOTTE,NC 28255-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
M A SCHAFER CONSTRUCTION. INC.
MARK SCHAFER 518-857-2121
4928 WESTERN TPKE
ALTAMONT NY 12009-0000
Plans&Specifications
2012-384
Comm Alteration-drive through area
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,August 16,2013
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Thursday,August 16,2012
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
OFFICE USE ONLY
l
TAX MAP NO. 9(p, 1q -l- T l a PERMIT NO. / a� - 3 X s) Date
FEES: PERMIT �`k O i., 2012
ci: RECREATION ENGINEERINGStStarr- ,
------- ___.112 9:4?
(If applicable)
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW
BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: /1/4500fe,-(6 Wai9jor) OWNER: fit/1k,e fir
ADDRESS: W I�J/'if'n S 4, 2Gn fcy/ , ADDRESS: UU _C.
PHONE NOS. .5-4-3 -2-d,?-2/ PHONE NOS. (s23 ) ' 165-(.36_,,C#7
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE:�Zv'Ks/*a y PHONE: /8-e :), .w/
LOCATION OF PROPERTY: a )id I //2&`- 41y /26d
HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES / NO
IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z
APPLY TO YOUR z
cc CJ o 1—
PROJECT O co w
O O
W � � JL W '� O = =
o F- u_ a z
Z < < Cf) Z
W Q —' H z O H O U^'
cvcn o � ° � a = xs
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL- .„
MERCANTILE „ '
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
l
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: bf,/{ l.,„r,-
ESTIMATED CONSTRUCTION COST: 2 46V FUEL YPE: .44'
HEAT TYPE: M *HOW MANY FIREPLACE(S): 47 9 AND/OR WOODSTOVES(S):A%A-
ZONING CATEGORY: /1/714 ARE THERE WETLANDS ON THIS SITE? 447/1
IS THIS A HISTORIC SITE? Aird
PROPOSED USE OF BUILDING OR ADDITION: 4\7311/ 19T,14° 72/x/24?
�J
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
B3-LGL 11-05
fal
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? /1/d
ARE THERE EASEMENTS ON PROPERTY? hid
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed
Director of Building & Codes: 761-8256 (for q stions regarding Building Permits, construction codes
or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application:
916
BU ,I +G & COD_•'APPROVAL ZONING APPROVAL
I
DA E.42 ,
DATE
-,
QUESTIONS? CALL 761-8256 OR EMAIL
codes(a.aueensbury.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issued: Yes No www.queensbury.net
Occupancy Type: Construction Classification:
Assembly Occupancy Limit: Special Conditions:
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Ins ctio u eceived:
Queensbury Building &Code Enforcement Arrive: Z`- am m Depart: JUL/d a /
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Q Pct. Vs, t F PERMIT#:
LOCATION: \ s13 ( 1 A 'E R n DATE: 10 Z 1 ?
COMMENTS:
Y N NA
Chimney/°B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6" in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior 1 Exterior Banisters 4 in. Spacing Platform I Decks
Stair Handrail 34 in.—38 in.I Step Risers 7"I Treads 11"
Vestibules For Exit doors> 3000 sq.ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44° (1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18°)Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supp y for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors
> 10% > 1000 sq. ft.
'/.Hour Corridor Doors&Closers
Firewalls I Fire Separation, 2 Hour, 3 Hour Complete I Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft_Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required CF-GEti J e-ND S , t
Elevator Operation and Siy aje/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets FV_`G €
Handicapped Bath I Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp I Handrails Continuous/12 in. Beyond[Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4° `
Water Fountain or Cooler i� \SI-70E1
Building Access All Sides by 20'/Driveable Surface 20'wide
Okay To Issue Temp. or Permanent CIO
Okay To Issue C/C
L:\Building&Codes Forrns\Buiiding&Codesllnspection FormssCommercial Final Inspection Report.doc Revised January 7,2008
GILSANZ . MURRAY . STEFICEK . LLP
Stnicturtl Engineers&Building Envelope consultants
129 West 27th Street,5th Floor
New York.NY. 10001
Tel 212.254.0030
Fax 212.477.5978
www.gmsllp.com
October 23,2012
Mr.John O'Brien
Queensbury Department of Buildings and Codes
742 Bay Road
Queensbury,NY 12804
Re: Bank of America, 183 Quaker Road, Drive-Thru Repair
Mr. O'Brien,
GMS has not performed a site visit to the Bank of America branch located at 183 Quaker Road in
Queensbury,NY to inspect the repair work at the drive thru canopy firsthand. However,GMS has
reviewed the special inspection reports prepared by Gifford Engineering dated 9/10/12,the concrete
compression tests prepared by Construction Technology dated 9/5/2012,and the photos taken by the
contractor during construction. The drive thru appears to have been repaired in accordance with the latest
set of drawings prepared by GMS dated 9/12/2012"Issue for Record."
Please do not hesitate to contact me with any questions you may have at 212-254-0030.
Sincerely,
41.
f.
Jon hon I[ernandez, P.E. S CB o . '` p�
Pa er
o 084.02
OCT 2 ` 2.012
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection reque ted•
Queensbury Building &Code Enforcement Arrive: 3 0y
3 a �/p JI -part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: r"
NAME: E2 k d\ PE-• I ' #: iZ— 3q4-k-
LOCATION: F C (n DA' : \o – \c–‘Z—
COMMENTS:
ZCOMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6" in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.–38 in./Step Risers 7"1 Treads 11"
Vestibules For Exit doors > 3000 sq.ft
All Doors 36 in.w!Lever Handles I Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44'(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap I Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 %doors
> 10% > 1000 sq. ft.
3A Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond[Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded I�
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File n
Building Number or Tenant Address on Building or Driveway 4' g5- ��`
Water Fountain or Cooler
Building Access All Sides by 20'/Driveable Surface 20'wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
— 'E 'V ANiA.
L:1Building&Codes Forms\Building&Codes\lnspectiaon Forms\Commercial Final Inspection Repord.doc Revised January 7,2
Foundation Inspection Report
Office No.(518)761-8256 Date Insertion d:
Queensbury Building&Code Enforcement Arrive: 11'2r) : p A� Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's In �
ti: I —
NAME: �A w) oF (;k-t EZAC•41 I T#: 7)(:?)\-1
LOCATION: 1c63 C1 \C {2_0 SPECT ON: !U--\O--\Z
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for 2-)0
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundaatioon Inspection Reportdoc
Last printed 12/20/2005 9:24:00 AM
CONSTRUCTION TECHNOLOGY
4 William Street,Ballston Lake,New York 12019
Phone:(518)399-1848 Fax:(518)399-1913
CLIENT: M.A.SCHAFFER CONSTRUCTION,INC.
REPORT NUMBER: 2 :PAGE#: 1
4928 WESTERN TURNPIKE
INSPECTION DATE: 09/05/12
ALTAMONT,NEW YORK 12009 OUR FILE NUMBER. 664.006
INSPECTOR&TEST SET: BRYAN CASAW #12
ATT'N: MR.MARK SCHAFFER
AMBIENT WEATHER: 70's:CLOUDY
PROJECT: BANK OF AMERICA: 183 QUAKER ROAD:QUEENSBURY,NY.
CONCRETE FIELD INSPECTION & COMPRESSION OTEUR ST LE ORESULTS
71
PLACEMENT LOCATION OF LOAD# 1 : DRIVE-THRU ISLAND BULL-NOSES:EAST&WEST ISLANDS
DELIVERED LOAD NUMBER: 1
TRUCK NUMBER/TICKET NUMBER: 208/ 6054846
YARDAGE DELIVERED I SUBTOTAL. 9.00/ 9.00
TIME CONC. BATCHED/ARRIVED: 9.01 / 9.21
TIME PLACEMENT BEGAN/ENDED: 9.28/ 9.47
CONCRETE AGE(HOURS) (SPEC: MAX: 1.50) 0.77
SLUMP ON ARRIVAL (INCHES): 4.00
WATER ADDED ONSITE(GALLONS):
WATER ADDED AT DISCRETION OF:
SLUMP OF CONCRETE INTO PUMP: IF APPLICABLE.
PLACEMENT SLUMP(INCH) (SPEC: - 5.00) 4.00
ENTRAINED AIR (°/VOL) (SPEC: 4.00- 7.00) 4.20
UNIT WEIGHT (PCF) (SPEC: - ) 151.32
CONCRETE TEMP. (F) (SPEC: 45 - 85) 78
NUMBER OF TEST SPECIMEN CAST: 6
LAB CYLINDER CONTROL NUMBERS 131371- 131376
DISCREPANCIES&REMARKS:
UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064
CONCRETE SUPPLIER: CLEMENTE LATHAM CONCRETE CORP. CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM:C39
DESIGN STRENGTH&FORMULA: 4000 P.S.I.@ 28 DAYS : UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: 09/06/12
CEMENT: LBS. CYLINDER TEST TEST AGE ULTIMATE UNIT
CEMENT: LBS. NUMBER DATE DAYS APPLIED LOAD P.S.I.
WATER: GAL.
COARSE AGGREGATE#1: LBS. 131371 09/12/12 7 54,350 4330
COARSE AGGREGATE#2: LBS. 131372 09/12/12 7 52.600 4190
COARSE AGGREGATE#3: LBS. 131373 10/03/12 28 60,950 4850
FINE AGGREGATE: LBS. 131374 10/03/12 28 62,100 4940
ADMIXTURE#1: OZS. 131375 10/03/12 28 61,450 4890
ADMIXTURE#2: OZS. 131376 SPARE
ADMIXTURE#3: OZS.
AIR ENTRAINING AGENT: OZS.
REPORT DISTRIBUTION:
1:FILE 5:
2:SUPPLIER 6:
3: 7:
4: 8:
RESPECTFULLY SUBMITTED,
CONSTRUCTION TECHNOLOGY
TOM JOSLIN,S.E.T. (NICET)
MANAGER TECHNICAL SVCS.
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection - d:
Queensbury Building&Code Enforcement Arrive: '� �'l� Depart: I.,r-/Qam/()
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: .411--
NAME:
/NAME: C i _! / PERMIT#: I i 3W--1
LOCATION: � � �'�� llIP INSPECT ON: I — I —f 7
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Foy 11/4)(
Reinforcement in Place � ^Q �t �` ��� �
The contractor is responsible for
providing protection from freezing �'n �M
for 48 hours following the placement `�—
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing AS B U I IT
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc