Loading...
2012-498 elfAh TOWN OF QUEENSBURY • 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120498 Date Issued: Friday, February 08, 2013 This is to certify that work requested to be done as shown by Permit Number P20120498 has been completed. Location: 289 BAY Rd Tax Map Number: 523400-302-007-0001-043-000-0000 Owner: C.R. BARD INC USCI DIV Applicant: C.R. BARD INC USCI DIV This structure may be occupied as a: Commercial / Industrial By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property �, 4 owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20120498 Application Number: A20120498 Tax Map No: 523400-302-007-0001-043-000-0000 Permission is hereby granted to: C.R. BARD INC USCI DIV For property located at: 289 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: C.R. BARD INC USCI DIV ATTN: ACCTS PAYABLE Commercial/Industrial $150,000.00 289 BAY Rd Total value $150,000.00 QUEENSBURY,NY 12804-0000 Contractor or Builders Name /Address Electrical Inspection Agency Plans&Specifications 2012-498 Heated Warehouse 624 sq ft $143.52 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,October 24,2013 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Wednesday, October 24,2012 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement • ,s"—"010 OFFICE USE ONLY TAX MAP NO. 3D �� - 1- 41,. .3 PERMIT NO. FEES: PERMIT_JSECREATION ENGINEERING (If applicable) OCT C 7 2012 PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. r-00 &12-eta APPLICANT/BUILDER:6..s2 •• 1:3'E OWNER: G- . e.)&1240 ADDRESS: ;431 gO_F_ouw Sm (p-i 14--c ADDRESS: 201t O(( Pte. QU BI/atf-j Y PHONE NOS._29 -2 f PHONE NOS. 713_-_2. %/ FRIM.\ kAU. - '- I CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: €404 -}-LpLL IPHONE: SSO- 161.04 LOCATION OF PROPERTY: _2131 A—( e, 17fi Q(A 65.t�{ __F�� __ _Q4 HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? 12YES ❑ NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: ?( - Z i Aub. Zo L2 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR Z O o U- O PROJECT Q < 0 OO • 0 I _ 0 w � `- �`• - u" = 000 Z Q Q � � N0 U_ OLL CL (XS SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE ETAI L- MERCANTILEi FACTORY OR Ma[ L I + INDUSTRIAL J ai-e V (0/-4� .� l ATTACHED (jW GARAGE(1,2,3) OTHER Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 • Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL—NAMEOF BUSINESS:_‘.g. W ESTIMATED CONSTRUCTION COST`1 0 GNU FUEL TYPE:__. HEAT TYPE: 41f Pie• "HOW MANY FIREPLACE(S): t'I/_AND I OR WOODSTOVES(S):__J./, ZONING CATEGORY: GLI ARE THERE WETLANDS ON THIS SITE? }\Q0e v-4J0uurs IS THIS A HISTORIC SITE? go PROPOSED USE OF BUILDING OR ADDITION: CO 011eotL 19 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 1`) ARE THERE EASEMENTS ON PROPERTY? Lum-gis4 e.o titin- eticvTPT4T- �? 'Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read nd a• -e to he .3ove. Signed �, ���' Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codesqueensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 (,6r - Dom Inspection Form / - f;svery-4 Town of Queensbury Fire Marshal O Periodic Inspection Date:A/if3 Time: r-/- 742 Bay Road,Queensbury NY 12804 a Re-Inspection ^,� 518 761 8206/518 761 8205 CO Inspection Permit#: o?0 Id -!k Marshals Representative PMJ Palmer Business Name: C12B4-�� 4-4/v. Location: Ar( {1-0 GK Stillman Contact: g e Piir:c, 0.6 'j9e -2 to 3/ r" diAri Type of Inspection N/A 7s No EXITS: Exit Access FC 1014&FC1029 j NOTES Exit Enclosure FC 1020&FC1029 Exit Discharge FC 1024&FC1029 / Locks and latches FC1008& FC1029.2 if _Sign:Normal FC 1011 &FC1029 Sign:backup FC 1011.5.3&FC1029.7.5 AISLES: Main Aisle Width FC 1024/1025& FC1029.11 f, Secondary Aisle Width FC 1025&FC1029.11 Al - FIRE EXTINGUISHER: Hung FC 906 // / Inspection of extinguisher FC 906 / ,& 111 EVAC Plan FC 404.6 TRUSS ID SIGNAGE FC 505.3 EMERGENCY LIGHTING: ; Interior FC 1006.3&FC1029.8r Exterior FC 1006.3 ` �1 , Clearance to Electrical FC 605.3 /! w�' Electric Wiring Enclosed/Labeled FC 605.3.1 / Combustibles in Equipment Rooms FC315.2.3 F.D.Signage- FC 510 /4- No `No Smoking Signs FC 310.3 / ' Storage FC 315.2 ----�+� Compressed Gas FC 3003 r, - i Vehicle Impact Protection FC 312.1 6 ;,. -�; r),4:-/1�fi I Interior Finishes FC 803-804 / I ,"i4iii.; �;' ''` .R fVai i Smoke Detectors FC 907 / i CO detectors FC 610 Clearance to Sprinkler/Ceiling FC 315.2.1 ? ; 18" / 24" ' _ EVAC SIGNS IN Rooms FC 404.6(R1 &R2) / ' - - Fuel Pump Warning Signs FC2205.6 Z. Fuel Station Emer Procedures FC2204.3.5 /' _i'!'rr.of= ;;v.1`.. ;'.._ _.. Exterior Storage FC 315.3 7, REINSPECTION DUE APPROXIMATELY Vacant Buildings FC 311 21 DAYS SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC Date Generator Annual DATE: OK NC Hood Installation Elevator Semi Annual FIRE ALARM Annual DATE: OK NC HVAC Shutdown Sprinkler System Annual Sprinkler FDC Kitchen Suppression Semi Annual V4-1WI ) ISv'pi?Iv� III - Fuel Island Suppression Semi Annual J� Hood Cleaning 3-6-Annual Knox Box:installed/checked FC506 6} 1 _nn .W'-1 411 ( "�C 1/ Operating Permit, if required will be issued after Gill' a< • Completion of Inspection t Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection request received: r}! P/ /_ 3 '_ Queensbury Building & Code Enforcement Arrive: am/pm Depaft: am/pm 742 Bay Road, Queensbury, N�Y 12804 Inspector's initials: r'�= NAME: CR 4PERMIT#: a/ - I / C LOCATION: AJpj.3 ! t. OL„, 1 ' DATE: - 7 - /- 1 ,3 .r_., d i.%: COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location kod Plumbing Vent Through Roof 6"/Roof CompleteC-Skir-C Exterior Finish/Grade Complete 6" in 10'or Equivalent +�� Interior I Exterior Guardrails 42 in. Platform/Decks 7 Interior/Exterior Banisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"1 Treads 11" Vestibules For Exit doors > 3000 sq. ft. � 1i °``7 All Doors 36 in. w!Levar Handles/Panic Hardware, if required D L, Exits At Grade Or Platform 36(w)x 44" (I)/Canopy or Equiv. ge� r� Tu Gas Valve Shut-off Exposed&Regulator(18")Above Grade o� Floor Bathroom Watertight I Other Floors Okay n`^ / Relief Valve, Heat Trap!Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area CeeCi u Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 V2 doors 6itc/c/‘ '> 10% > 1000 sq. ft. p /^` s/ Hour Corridor Doors&Closers Firewalls I Fire Separation, 2 Hour, 3 Hour Complete I Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Space Access 18" x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded V Site Plan/Variance required Final Survey, New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler _ Building Access All Sides by 20'!Driveable Surface 20'wide Okay To Issue Temp. or Permanent C!O Okay To Issue C/C L:1Building&Codes Forrns\Building&Codes\lnspection Forms1Cornmercial Final inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report t-\\ --T:\ Office No. (518) 761-8256 Date In pecti9n - :.:' ed: Queensbury Building &Code Enforcement Arrive: �1�, a s part: �� 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. . E NAME: - 0 /PERMIT#: \ z_.- '41?) LOCATION: i•- • `�+;(� INSPECT ON: l --7, -).--1 TYPE OF STRUCTURE: C_()13T O LL CE_ 0 '2)-TO RAS GL- . Z. , 'C—��v\Iv y/ 'tN NIA COMMENTS: Framing k-- \\\` , \/ Attic Access 22" x 30" minimum Jack Studs/ Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more , Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses 3 Anchor Bolts 6 ft. or less on center I and water shield 24 inches from wall / Fire separation 1, 2, 3 hour ? c71— Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/ below grade 5.0 sf grade _ L:\Building&Codes Fomis-OLD\Building&CodesUnspection Fomms\Framing Firestopping Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection - G-i ed: Queensbury Building &Code Enforcement Arrive: "- -rt: 742 Bay Road, Queensbury, NY 12804 Inspector's Initi NAME:, C 1 1) " RMIT#: \ Z -\ \ -' CC) LOCATION: ? ' I SPECT ON: TYPE OF STRUCTURE: C0I;)--1-R L_L�=\� 1 t� � K-� t- c \ YN NIA COMMENTS: Framing / Attic Access 22" x 30" minimum t ECk\ 1\-C_7 Jack Studs/ Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/ Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space / Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-OLD\Building&Codesllnspection Fomis\Framing Firestopping Inspection Report.doc Revised January 7,2008 y ham RUCINSKI HALL ARCHITECTURE , Ronald Richard Rucinski .�` 04 Ethan Peter Hall ti- 627 Maple Avenue •<Z-- Z Saratoga Springs NY 12866 ,. � Voice 518 580 1905 Fax 518 584 5012 Email ephall@nycap.rr.com Special Inspection Report To: Dave Hatin - Town of Queensbury— Building Department From: Ethan Hall Date: 28 January, 2013 Re: C R Bard — Controlled Storage Facility — Structural & Foundation Observations At the above project location this office performed periodic construction site visits and observed construction progress throughout the construction of the project. The foundation and structural steel installations in particular have been done in accordance with the construction drawings and shop drawings as provided by the pre-engineered metal building manufacturer. All work is acceptable to this office. If there are any questions please contact our office. Regards, ftf,s ..r, Ethan P. Hall', , Cc: Ron Greene—C R Bard 1':\CR Baid'•.Controlled Storagc Facilit!,TaperworkiSpccial Inspection Report 25 Jan 2013.doc 1 fik& Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspe ion request received: Queensbury Building &Code Enforcement Arrive: #(-0 am/prrjm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: .Z NAME: c f PERMIT#: J c Y 7 LOCATION: DATE: COMMENTS: Y N NA +) Chimney/"B"Vent/Direct Vent Location s ,r r> Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6" in 10'or Equivalent Interior I Exterior Guardrails 42 in. Platform I Decks ,(lea S--b.k -€) Interior 1 Exterior Bailisters 4 in. Spacing Platform/Decks Stair Handrail 34 in. —38 in. l Step Risers 7"/Treads 11" 1 C J -_' Vestibules For Exit doors> 3000 sq. ft. All Doors 36 in. w/Lever Handles/Panic Hardware, if required 9 to- 8 `7,Exits At Grade Or Platform 36 (w)x 44" (I)/Canopy or Equiv. Gas Valve Shut-off Exposed & Regulator(18")Above Grade Floor Bathroom Watertight I Other Floors Okay Relief Valve, Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy I Ventilation Combustion / Low Water Shut Off For Boilers ` C "�/'�'Y Gas Furnace Shut Off Within 30 ft. or Within Line Of Site ',h J ( T/ Jt't'e . ► Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room (2 hr.), I %doors _ 2�vj,� <<„ A:14. > 10% > 1000 sq. ft. '/, Hour Corridor Doors&Closers Firewalls I Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30" x 20"x 30" (h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks I Toilets Handicapped Bath 1 Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond (Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides byte Surface 20'wide Okay To Issue Temp. or ermanent C I/ Okay To Issue C/C _ L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Revised January 7,2008 (.it) d- / b /j Foundation Inspection Report Office No.(518)761-8256 Datedo�.',i, - • - •' ed: Queensbury Building&Code Enforcement Arrive: qrt7 / a epart: CT,. 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial- A NAME: a 86, f-cPERMIT#: / ,;.-- 'CI 9g LOCATION: 9 Q cc((4 R INSPECT ON: //—)/--/.Q TYPE OF STRUCTURE: (1,t- 1,J 6 ALf1 Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place • Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing ,- Footing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width /� 6 inches above footing (% ! 6 mil poly for wet areas under slab f Backfill Approval f Plumbing Under Slab vv Ct?VC /Cast/Copper -oundation Insulati Interior terior V R- \v Z 'r I'- ,..1, Rough Grade 6 inch drop within 10 ft. L:\Building &Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Ins I tion . : iv s: Queensbury Building&Code Enforcement Arrive: - .: Depart: 1 -- 742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini.: s: NAME: C rd :'ERMIT#: I `y ? LOCATION: 64r INSPECT ON: — 1 -17 TYPE OF STRUCTURE: �J Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Buliding&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report doc Last printed 12/20/2005 9:24:00 AM r Jq 1- 3 Foundation Inspection Report Office No.(518)761-8256 Date Inspection requ-. -iv ': Queensbury Building&Code Enforcement Arrive: 7-'1D rjalie Depart: AVP: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME:E: C 62 PE.1, I T#: 10) - y a g' LOCATION: _� �, R(tvf INS'ECT ON: //-�- TYPE OF STRUCTURE: 19L gra 3 1 Comments Y/ N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM