Loading...
2012-545 9.111% TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 Q r}, Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20120545 Date Issued: Thursday, September 26, 2013 This is to certify that work requested to be done as shown by Permit Number P20120545 has been completed. Location: 1602 STATE ROUTE 9 Tax Map Number: 523400-288-008-0001-011-002-0000 Owner: RASHEED BHATTI Applicant: RASHEED BHATTI This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property r' A-- owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building& Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 13siv Roml,Queenstmiry,NY 12804.5902 (518)761 8201 1 2t Cointnunity Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P'20120545 Applicatiot-i Number: A20120545 "Fax Map Not 523400-288-008-0001-011-002-0000 Pe rinissio n is hereby gra n tcd to: RAS11EED1311ATTI For property kxatcd at: 1602 STATE ROIJTIy` 9 in theTov,ii of Qucensbur'v, to construct or place at tile above location in accordance with application together with plot plans and other information hereto filed I and approved and M compliance with the NYS LJnifog C rm Building.; and the QucensbUl-I z Ordillitice. Type of Construction Value Owner.,\ddress= RASHEED BFIATTI Coniniercial Alteration $9,000.00 932 STATE ROUTE 9 MOT EI- 1:otal Value $9,000.00 QUEENSBURY NY 12804-0000 Contractor or Builder's:".lanae / Address .1-1ectrical Inspection Agency 13HATTI BROTHERS, LTD 792-0418 1602 STATE ROUTE 9 LAKE GEORGE NY 12845-0000 Plans&Specifications 2012-545 Connniercial Alteration 720 sq ft total - Enclosed porches/balconies I st Flr - 4 porches @) 90 si" 21ld Fir- 4 balconies (y), 90 st' $144.00 PERMITFEE PAID-THIS PERMITEXPI RES, Friday, November 15, 2013 (If a longer period is required,an application for an extension must be nlad(:to tile code Enforcement Officer of theTown of Queensbury before the expiration date.) Dated at the Town of Queensbury; I'lliursday, Noveniber 15, 2012 SIGNED BY fear the TCAM 0C Q LICC i isbuw-N. Director of Building&Code I:nforcenlcnt LYS cuxis4 , oe 1-li ;---Nd,),- ,__1<s ,416,/.,/____ _ 44 V ii hq l� r OFFICE USE ONLY , TAX MAP NOa0 a_ 1 -11. _ ---PERMIT NO._/?-_ 5 __ 1h � . 'w 50 ` Vv FEES: PERMIT RECREATION ENGINEERING ; NOVr ,' ZOIC__ _ V_ (If applicable) , PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/B/UILDER:B/ /-/; ,&61.64_�J 1/�� OWNER: `\ /1S1T C-'e ) �,.NF''pt'1)j ADDRESS: /l'C2 5i77Z- 0,4.- 9 Ua/tc 64-171iAY ADDRESS: 9-31? &TAT( g- (1j 0gVi8619) PHONE NOS.��/� 191 --04//r- �L PHONE N0kcI� 7961"- a2 9 99 CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: PHONE: l' LOCATION OF PROPERTY:/MO.2 . 7-6-- /4-9- 6314= C,ir�nfic 4)/ /2,)--v) -- ._ �/ HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? 0 YES ,ANO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: 1 Do PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z o(k, APPLY TO YOUR Z 0 co a111 LL PROJECT 0 < 0O p • c[ _, 0 F- w W OF- JI- W J O = 2 Wa J W o = I- OCL LiZ Z < < :- � N � I- 0u I ° � CC a = te I SINGLE FAMILY TW O-FAMILY a -I- MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE • Q 1� BUSINESS OFFICE RETAIL- MERCANTILE � rpF R � � ,cf ji ' Iti cl oWi/ � try e j •/- - 905 [AGA (TH-Ei.:-'-\/V) 'S 3(0O4 3a S f 4 7p26sF i vs 6,-*-;,(,( C,JA Y oLere., 4-14 Rat were - ) •'.c, ue pare4 , IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: C ESTIMATED CONSTRUCTION COSTS OO U FUEL TYPE: r HEAT TYPE: *HOW MANY FIREPLACE(S): AND I OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? _ PROPOSED USE OF BUILDING OR ADDITION: M( I L Po 'Y�� , , r/ 'Gtl C_c7k(`e S - ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? "Please complete a separate Appii cation for'Fuel Burning Appliances&Chimneys' available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I 4e read and a..-- to t e a..ve. r yr Signed —1.411.r-421° / i' Director of Building & Codes: 761-8266 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: �1 BUIL') & COD: i'•OVAL ZONING APPROVAL V DA E DATE • QUESTIONS? CALL 761-8256 OR EMAIL codes(aqueensbury.net Office Use Only . • VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury* Community Development Office * 742 Bay Road, Queensbury NY 12804 Commercial Fina Inspection Report Office No.: (518) 761-8256 Date Inspection r est / ed r Queensbury Building & Code Enforcement Arrive: 't-I7b a •• Depart: pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initia s: .. . • NAME: 11..C �1 i�Of�=�L `N\zsi-E- PERMIT t ��—. �►=� LOCATION: 1 L 2 �T 1 F liZrADIE DATE: a Z' — COMMENTS: Y N NA Chimney/ "B"Vent/ Direct Vent Location Plumbing Vent Through Roof 6"/ Roof Complete / Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/ Exterior Guardrails 42 inch Platform / Decks Interior/ Exterior Balusters 4 inch Spacing Platform / Decks Stair Handrail 34 inch—38 inch / Step Risers 7"/Treads 11" \,/ Vestibules For Exit doors > 3000 sq. ft. All Doors 36 inch w/Lever Handles/ Panic Hardware, if requ'red Exits At Grade Or Platform 36"(w) x 44"(I)/ Canopy or Equiv. �f Gas Valve Shut-off Exposed &Regulator (18") Above Grade Floor Bathroom Watertight/ Other Floors Okay Relief Valve, Heat Trap / Water Temperature 110 Degrees Maximum Boiler/ Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/ Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stcckroern/Storage/Receiving;'Shipping Room (2 hr.), 1 '12 doors > 10% > 1000 sq. ft. 3/4 Hour Corridor Doors &Closers Firewalls/ Fire Separation, 2 Hour, 3 Hour Complete/ Fire Dampers / Fire Doors Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/ Shaft Sealed Handicapped Bathroom Grab Bars/ Sinks/Toilets/ Mirrors Handicapped Bath/ Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 inch, Checkout 36 inch Handicapped Ramp/ Handrails Continuous/12 inch Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical/ Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/ Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/ Drivable Surface 20'wide . Special Inspections/ Engineer or Architect Approval _ I` Okay To Issue Temporary or Permanent C/O V . - Okay To Issue C/C Commercial Final Inspection Report_revised 11-27-2012 Commercial Final Inspection Report4 Office No.: (518) 761-8256 Date Inspection requ-. .-_-ive•: ?/ c/ 3 Queensbury Building & Code Enforcement Arrive: VA6 a ' . �- Depart: V:1,• a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. `✓ r / NAME: I_-, 1"f�'G (I PERMIT 5-1/ LOCATION: r(e0. DATE: i` • .,// COMMENTS: Y N NA Chimney/ "B"Vent/ Direct Vent Location / T Plumbing Vent Through Roof 6"/ Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/ Exterior Guardrails 42 inch Platform/ Decks Interior/ Exterior Balusters 4 inch Spacing Platform / Decks Stair Handrail 34 inch - 38 inch / Step Risers 7"/Treads 11" iJ aEo To C-D C Vestibules For Exit doors > 3000 sq. ft. All Doors 36 inch w/Lever Handles/ Panic Hardware, if requiredl_PZJT Ttx. oVJD ") Exits At Grade Or Platform 36"(w) x 44"(l)/ Canopy or Equiv. 4 To? L. Gas Valve Shut-off Exposed &Regulator(18")Above Grade Floor Bathroom Watertight/ Other Floors Okay Relief Valve, Heat Trap / Water Temperature 110 Degrees Maximum Boiler/ Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 1/2 doors > 10% > 1000 sq. ft. 3/4 Hour Corridor Doors &Closers Firewalls/ Fire Separation, 2 Hour, 3 Hour Complete/ Fire Dampers / Fire Doors Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/ Sinks/Toilets/ Mirrors Handicapped Bath / Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 inch, Checkout 36 inch Handicapped Ramp/ Handrails Continuous/12 inch Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical/ Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/ Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/ Drivable Surface 20'wide Special Inspections/ Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O Okay To Issue C/C Commercial Final Inspection Report revised 11-27-2012 Commercial Final Inspection Report� /1 h �rs �� R Office No.: (518) 761-8256 Date Inspection -• Queensbury Building &Code Enforcement Arrive: 7-20 a4,41rA�� Depart: 7--%- a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial-'�- i/ NAME: i0 6:1 \--\ Ar_ PERM Lis LOCATION: /L;0-.--A i I DAT-. Lc COMMENTS: Y N NA Chimney/°B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6" in 10'or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Banisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. I Step Risers 7"I Treads 11" L1_N3E1._ Vestibules For Exit doors> 3000 sq.ft. All Doors 36 in.w/Lever Handles/Panic Hardware, if required / _ ��c30 Exits At Grade Or Platform 36(w)x 44°(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade `J Floor Bathroom Watertight I Other Floors Okay Relief Valve, Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System � -� L ► Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Tr) Oil Furnace Shut Off at Entrance to Furnace Area � ‘,'`Z-�' Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/1 doors > 10% > 1000 sq. ft. ' Hour Corridor Doors&Closers Firewalls I Fire Separation, 2 Hour, 3 Hour Complete I Fire Dampers/Fire Doors t Ceiling Fire Stopping, 3,000 sq.ft Wood Frame %0 Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required ,\ Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks I Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical I Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspc ction ForTns\Commercial Final Inspection Report.doc Revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reque. - - + - •• ,,� Queensbury Building &Code Enforcement Arrive: Z--4-1D a J,� -p : 7 :,L,, arr"" r 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ..1, NAME: .. L,N • /.. ' .. PERMIT #: /, LOCATION: / Leo - + 9 INSPECT ON: -W -z-) TYPE OF STRUCTURE: Y N NIA Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction Pressure Test Drain/Vent Air/Head 013 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head t �r 50 P.S.1 for 15 minutes Insulation / Residential Check/ Commercial Check q Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) tea➢ Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report We Office No. (518) 761-8256 Date Inspection requ‘- re.ived: Queensbury Building &Code Enforcement Arrive: �-`- , a L:part: 2 ; 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: .\`-�c:. , L, -1 ERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: (jCrn/71- l2z-177 Y N N/A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing /Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches I Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bofts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour -- Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/Z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/ below grade 5.0 sf grade L:1Building&Codes Forms-OLD\Suilding&Codes\Inspedion Fomts\Framing Firestopping Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report is /Dye Office No. (518) 761-8256 Date In aquestrcei 1 % z. Queensbury Building &Code Enforcement Arrive: = : - ,pin 742 Bay Road, Queensbury, NY 12804 Inspecto s Initia s: NAME:_ 19441 4'11 /4;i) f 't (("'.< (L "&.e- � 1 PERMIT#: 1 L% 11"/ LOCATION: O r a U'T e j INSPECT ON: TYPE OF STRUCTURE: A COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/ Headers Vt Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly ' c11- \ " 7 \3 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. • Notches I Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side YZ inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:16uilding&Codes Forms-OLD\Building&CodesJnspedion Fam s\Framing Firestopping Inspection Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report ri\c ncla l -3 Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: 3'10 am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: "3,/' NAME: 4-1" .�i I , PERMIT#: b-- 1 5 LOCATION: I INSPECT ON: -1) TYPE OF STRUCTURE: &&(r c " rn ,Pi I --F Framing N N/A COMMENTS: Attic Access 22" x 30' minimum Jack Studs/Headers Bracing/Bridging Joist hangersc�/ 1 Jack Posts/Main Beams _ h s firy If .J� ,f9�/ (.i) noi2 Exterior sheeting nailed properly 12"O.C. (44 // 64/1` 1.0 Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing - dc, r»/JJhis Headroom 6 ft. 8 in. • Notches/Holes/Bearing Walls ,R- /3 0, Metal Strapping for Notches Top Plate 1 '/(w) 16 gauge (8) 160 nails each side - ! n'1 C'J ' y�Uu uc c fes, c �� Draft stopping 1,000 sq. ft. floor trusses (A/c/4 Anchor Bolts 6 ft. or less on center _ rey_�if-rue F r-t: �' Ice and water shield 24 inches from wall 9 Fire separation 1, 2, 3 hour ...... // - re/7:5Q-17u-- Fire wall 2, 3, 4 hour �v L��"rr, Firestopping ✓✓ Penetration sealed 16 inch insulation in cavitymin. SA y4/� Y �� Garage Fire Separation y� House side 's inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall - fvo e4 Windows Habitable Space/ Bedrooms 24 in. (H) 20 in. (VV) 5.7 sf above/below grade 5.0 sf grade L:\Bui ding&Codes Forms-0LD\Building&Codes'nspection Forms‘Frarning Firestopping Inspection Report.doc Revised January 7,2008 , be 1 i \--5 9 5 NEW 2 X 6 NOV I A 2012 R-31 INSULATED END UNITS EXTENDED ROOF END UNITS H 12"ON CENTER EXISTING ROOF NEW 2 X 6 JR-31 INSULATED • MIDDLE UKT,S � �J� ���U �F EXTENDElYli eF Q ------------ 2' 12" ONC T C 'T � 1 Iam r1eviewed Be = '.,y _ _. — /1 /0 /'— MIDDLE bj._ li i. r'. mENT EXISTING ROOF EXISTING PORCH SECOND - ' 2' '1 , _tN^,F=,�+.gisnnonteCcmo,agctC" —NEW EGRESS 35-1/2" FLOOR EXISTING PORCH WINDOWS ALL NEW WALLS CONSTRUCTED //WITH 2" X 6" STUDS,16" ON CENTER INSULATION: R-19 ,1/2 SHEET ROCK _ EXTERIOR: TYVEC --7 WITH T 1-11 SIDING . EXISTING -- PORCH ���� FIRST EXISTING .may r PORCH NEW FLOOR 33-3/4"WINDOWS NEW STEEL DOORS ► //1i JA.,,/ 3 /36"W X 80" ► / 4— !� (4)1 fst Floor only — 1 c�0 2"x 10" EXISTING BEAM - .r-1/1 7" /��542- 4- I. . NEW WOOD STEPS 4' x 8" 1/2 plywood, over all decking 4'W 12" TREAD I 4 I EXISTING FOOTING/ ELEVATION TAX #288.8-1-11.2 SIDE VIEW RASHEED BHATTI 1602 STATE RTE 9 Proposed Enclosed QUEENSBURY,NY Porches DATE: 11-14-12 REAR ---EMBN T--- - _____ ---- - ALL NEW WALLS CONSTRUCTED .. - TYP 4' WITH 2" X 6" STUDS INSULATION: R-19,1/2SHEETROCK 12" TREAD WOOD STEPS EXTERIOR: TYVEC WITH T 1-11 SIDING NEW TYP DOOR WINDOW • WINDOW 36"- 1/2 X 80" NEW Q TYP 15'-0" ► DOOR DOOR WINDOW _. ._ EXISTING EXISTING 33"-314 X 48" PORCH PORCH (H H WINDOW • D00- EXISTING EXISTING DOOM WINDOW SLIDER SLIDER , EXISTING EXISTING m PORCH PORCH EXISTING EXISTING SLIDER EXISTING EXISTING SLIDER ROOM ROOM EXISTING EXISTING ROOM ROOM PLAN VIEW FIRST FLOOR TAX # 288.9-1-11.2 Proposed Enclosed Porches RASHEED BHATTI p 1602 STATE RTE 9 QUEENSBURY,NY DATE: 11-14-12 Elyg REAR _-- ........... ANKh'1E NT _ _.ter . _ __ —-r — ————....— — —————. _ --- ALL NEW WALLS CONSTRUCTED �% WITH 2" X 6" STUDS INSULATION: R-19,112 SHEETROCK EXSTERIOR: TYVEC WITH T 1-11 SIDING WINDOW , WINDOW 1. TYP 15'-0" WINDOW EXISTING EXISTING 35-1/2" X 59-1/2" PORCH PORCH WINDOW 1 0 EXISTING EXISTING ROOM SLIDER SLIDER C EXISTING , PORCH EXISTING io PORCH EXISTING EXISTING SLIDER EXISTING EXISTING SLIDER ROOM ROOM EXISTING EXISTING ROOM ROOM PLAN VIEW SECOND FLOOR Proposed TAX # 288.8-1-1t2 Enclosed Porches RASHEED BHATTI 1602 STATE RTE 9 QUEENSBURY,NY DATE: 11-14-12 r _ tin -y �moaa aID n r 2 c r �m�� cc�c m irn�r �m,n"'a m Z�_0 <0m 0Jz Ur Nm m co IS 2 co C'1 .e m ci `I m 1 I IRF _ .. S83 44'20"E D/ 6 368.73 w I m i IRF 4" SQUAREE, CONCRETE MONUMENT o Jt' o �� a A — f s z / w co 00 l._= m = I z - y r Y ' . lI\ co 41. co �u Y. HOUSE ' l OFFICE f I � zs.r MOTEL UNITS co ,,,, YYYYO / PORGH f , 1 O � CABIN SIGN CABIN a 03 CABIN wco co ca CD Cb let -10 1+ cil 00 CABIN W25 let14 ao° I`. co O I W I <a N ti }y} M o ° STAIRS PUMP ° fC ABIN { � 2 L J t m 9 CRUSHED STONE m n �^ i t I CONCRETE ❑ `s ne DWAu _0 c:co r X11 6 o - o { w N O O � }. Ut oN a V i mo O M W V r N N EE' f� w i to cD PLAYGROUND / IRS t > 2 9 6.07 I IRs —7 S86, °37'27"W i 1 hL_ i i L . lI r i R I _ _. -..,....ice - Z �- n •Di � r _ , �; _ ::,.., ;.�� t=� - — -- �..