Loading...
2006-111e" TOWN OF QUEENSBURY 742 BayRoad, Queensbury, NY 12804-5902 (518)761-8201 ��� Q r1'� Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20060111 Date Issued: Friday, August 26, 2011 This is to certify that work requested to be done as shown by Permit Number P20060111 has been completed. Location: 358 SHERMAN Ave Tax Map Number: 523400-309-005-0001-005-000-0000 Owner: BRIAN & SHANNAN BOHL Applicant: RICHARD BOHL This structure may be occupied as a: Commercial / Industrial Unheated By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the t/ , , t '1 property owner of the responsibility for compliance with Site Plan, 2 i 4 ✓ Variance, or other issues and conditions as a result of approvals by the Director of Building & Code nforcement Planning Board or Zoning Board of Appeals. Oieha TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060111 Application Number: A20060111 Tax Map No: 523400-309-005-0001-005-000-0000 Permission is hereby granted to: RICHARD ROHL For property located at: SHERMAN Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction alue Owner Address: RICHARD BOHL PO BOX 7 Commercial/Industrial Unhea $85,000.00 Total Value $85,000.00 GLENMONT, NY 12077-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2006-111 4,900 SQ FT STORAGE UNIT AV 10-2005 and SPR 3-2005 $245.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, April 13, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of nsbury; Thursday, April 13, 2006 SIGNED BY / ,(/ 1 - for the Town of Queensbury. Director of Building&Cod'IF 'o ent Building Permit No.: 2006 - /10ZO -I 1 1 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUIPANCY A TEMPORARY CERTIFICATE OF CSS OCCUPANCY is hereby requested for the property located at: . Ari5Aerrnck to A I<C._.n ue For the following use(s): (2) S±O1tk 5 e U to ►-I- I understand that if the conditions that follow are not met before the expiration date, the deposit is forfeited. j-,-„/„.A_ti.,(//,,,c_ i ... .. ignature of Applicant Date A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby APPROVED DISAPPROVED with the following conditions: II Ii n r1� 1) o /'13P, C O r fJ ielec ' I.rt. ay 2007 .2)(10 n C ! 511e_ /.ssves 3 p .C; .l7 c ll y v-; in G ) S v h m ; cep*, (led c s b v f 1-/- 5 i:-4e_ pit In 11) need -f<iia/ \5 ; . -pkv, ;nspeCfo^- 7 s) ri-e-e cam# -ri I T`1'Jh a I 1-J)--Vey 6 /0„00 FEE: $10.00 DEPOSIT: ri $100if RECEIVED ON: /2 Z -D J04 / / - - 12 _2 _ O Director of Building & Code En orcement* Date of Issuance** *This Certificate is NOT VALID unless signed by the Director of Building & Code Enforcement or his designee **This TEMPORARY CERTIFICATE OF OCCUPANCY expires 1 gO days from the Date of Issuance OFFICE USE ONLY r - / TAX MAP Nq3 a 5 '— PERMIT NO. OG - a ( FEES PERMITD,45,0 RECREATION ENGINEERING (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. ((�� APPLICANT/BUILDER: �K�Ch 0. D OWNER: •c� cQ \dLL Q, wO-s fi E)° `/ ADDRESS: Q.p SOS �&. u.ya \ ADDRESS: \)-.Q._e-i• AP? /2...0 (Xk.)-0-42Ato ri) PHONE NOS. ci Er - [rl 6 �� PHONE NOS. -C7d a 6 626 2 S';8- TS-7 .6 6 2.. CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: �. � % PHONE:.. Jg 376 LOCATION OF PROPERTY: S �.Q-malV ALM_ ���ev�r �� NY( 1..1. E-0(4 SUBDIVISION NAME: a‘N-L- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT ZO APPLY TO YOUR z0 Q aO C/) CJ w u- PROJECT O O O F- _ u_ LLa 2U z a a u_ d N ° o � �°aCC = CL c?5 SINGLE FAMILY TWO-FAMILY MULTI-FAMILY I (NO. of UNITS ) 'RECEIVED ECFIVED TOWNHOUSE MAR 1 3 `0116 BUSINESS OFFICE TOWN OF OUcI='��3URY BUILDING A,\D CODE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER WO (J V90-° IF COMMERCIAL OR INDUSTRIAL-NAME OF QQ,,t)SINESS a. -&,,voL �s5� doJ cv ESTIMATED CONSTRUCTION COST: Pleas 'plete a separate Application for Fo. A,,rning Appliances&Chimneys' avail n. our office HOW MANY FIREPLACE(S): 0 AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? n 6 PROPOSED USE OF BUILDING OR ADDITION: P\ B 3-LGL 11-05 Tovell of owt,ilsbur1J • Community Development Office * 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) i Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL DATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codes(@,queensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION i www.queensbury.net_______ 7`awn a] Or.iren5buri/ • Community Development Office • 742 hay Road I;>ueen51,ury, N1 72804 SENTINEL BUILDING SYSTEMS P. 0. BOX 348 ALBION, NE 68620 (800) 327-0790 RICHARD BOHL 11 "C." RIVER ROAD GLENMONT, NY 12077 Jobsite Address: SHERMAN AVE QUEENSBURY, NY 12804 Date: 2/17/06 Re: Sentinel Building Systems Job Id: B21451 Dear Sir: This letter is to certify that a 35' span, 140' long gable symmetrical building with a 9.5' eave height as referenced above and manufactured by Sentinel Building Systems of Albion, Nebraska is designed in accordance with the following loads: Live Load: 20 psf (roof system) Collateral Load: 0 psf Roof Snow Load: 60 psf Wind Load: 90 mph Exposure C Dead Load: 2.2 psf (wt. of the building) Seismic Zone/Design Category: C Seismic Coefficient: 0.520 (Ss*Fa) Loads are applied in accordance with the NYBC 02 building code. The certifying engineer does not certify that the building code or loads specified are adequate or appropriate for the intended use or location of this building. Design is in accordance with the applicable sections of the 1989 AISC and the 1996 AISI specifications. This certification is limited to the steel framework, the metal roof and the metal wall covering, and fasteners required for their installation. This certification specifically excludes an analysis of the foundation and parts supplied by anyone other than Sentinel Building Systems. Sincerely, SENTINELD U ; A, SYSTEMS LES, ; Jer4., r.34.1 ;. ► C Bll111C}�=. .33" ; W A .G <c /► . Charles . 4,1 . Certifying Engineer 04/1212006 12:25 5184891897 PAGE 02 New York Office 300 Great Oaks Blvd. • Albany, New York 12203 I 1 I Phone: (518)690-0790 e r'4 , i n e e r i n g Fax: (518)6'90-0793 April 12,2006 nn,r16 Mr.David Halpin Town of Queensbury TOP'N ` : _' =, CGDE 742 Bay Road gt1,t_�;1fi:`' .Queensbury,NY 128 • RE: Sherman Avenue Self Storage Dear Mr,Halpin Infinigy Engineering was selected as the engineer of record for the above referenced project.I am writing to inform you that Infmigy Engineering will be responsible for completing the site inspection to confirm,the facility was constructed in compliance with the design. Infinigy Engineering will retain Construction Technology to complete the concrete testing for the foundation. If you have any additional questions regarding this project please do not hesitate to contact me at(518) 690-0790. Sincerely, /10.0.4vc ohn Stevens P.E President/CEO Infinigy Engineering 810 Marietta Highway • Roswell, Georgia 30075 300 Greet Oaks Blvd. • Albany, New York 12203 770-640-9969 518-690--0790 www.infinigy_com ) -3 -22 —06 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection eque- - O--- --OC. Queensbury Building&Code Enforcement Arrive: Al • ►10Depart: \ 742 Bay Rd.,Queensbury,NY 12804 Inspector's -�j� NAME: R tCl'lekij Eink,1I(IIT : Q — LOCATION: •-g 54. S + v y,3jr`. INSPEC ow• �'Yi i 2 TYPE OF STRUCTURE: Cnv air ner—C i a I /O'I'ec±eC DL_. ) Comments1 C - ILT rA((3)/iotings V` f (beAcvl\ `W Piers �� Monolithic Slab einforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM , • i i n v . New York Office A 11 Herbert Drive engineering & surveying Phthani,NY 12110 ne: (518)690-0790 Fax (518)690-0193 www.infinigv.com November 4, 2008 David Hatin Director of Building& Code Enforcement Town of Queensbury 742 Bay Road Queensbury,NY 12804 RE: Sherman Avenue in the Town of Queensbury, NY Dear Mr. Hatin: The construction of the storage units built on Sherman Avenue in the Town of Queensbury, New York by Richard Bohl were built according to the specifications, drawings and details provided by Sentinel Buildings, dated April 26, 2006 and by the drawings dated March 10, 2006 by Infinigy Engineering. Respectfully submitted, Infinigy Engineering& Surveying,PLLC John S. Stevens, P.E. NY License Number: 071096 JSS/Idi GA Office: 2255 Sewell Mill Road,Suite 130, Marietta, GA 30062—Phone: 678444.4463 -Fax: 678-444-4472 VA Officci 3 South 12th Street,2nd Floor, Richmond, VA 23219—Phone: 804=788=8940—Fax: 804-788-8941 WI Office:64 N. Main Street,Suite B_Hartford, WI 53027—Phone:262-670=9530-Fax: 262-670-9560 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 0A PERMIT#: 06_0 LOCATION: s 8- _ ' ✓-Q— INSPECT ON: TYPE OF STRUCTURE: Y N N/A Framin 9 COMMENTS: � -A-ftic Access 22" x 30" minimum Jack Studs/ Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams 414&i.eAl /��Exterior sheeting nailed properly / > 12" O.C. �i // 4tem on 4 Headroom 6 ft. 8 in. Stairwells 36 in. or more � Exterior Deck Bracing our Q I A fn /Ai ih pec C- Headroom 6 ft. 8 in. / Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'A inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1Building&Codes Fortes-OLD\Building&Codeslinspection Forms\Framing Firestopping Inspection RepoRdoc Revised January 7,2008 ip rr`N g New York Office y 11 Herbert Drive engineering & surveying Latham,NY 12110 Phone: (616)690.0790 Fax: (518)690-0793 www.intinlev.com November 4, 2008 David Hatin Director of Building&Code Enforcement Town of Queensbury 742 Bay Road Queensbury,NY 12804 RE: Sherman Avenue in the Town of Queensbury,NY Dear Mr. Hatin: The construction of the storage units built on Sherman Avenue in the Town of Queensbury, New York by Richard Bohl were built according to the specifications, drawings and details provided by Sentinel Buildings, dated April 26, 2006 and by the drawings dated March 10, 2006 by Infinigy Engineering.— — Respectfully submitted, Infinity Engineering&Surveying,PLLC (it; I. Jolin S. Stevens,P.E. NY License Number: 071096 JSS/ldi OA Office:2255 Sewell Mill Road,Suite 130, Marietta,OA 30062- Phone:678-444=4463 •Fax: 678:444-4472 VA Office: 3 South 12th Street,2nd Floor, Richmond, VA 23219--Phone: 804-788-8940—Fax: 804-788-8941 WI office:64 N. Main Street Smite.R. t-iliiitfnrd- WI 51071-..Phone! l(7a;7O-9V'i0-Parc• ;'6'7-00-956f1 �l'� it November 18, 2008 Mr. David Hatin Director of Building & Code Enforcement Town of Queensbury 742 Bay Road Queensbury, NY 12804 Dear Mr. Hatin: This letter is to formally request a temporary Certificate of Occupancy for the storage units erected on Upper Sherman Avenue in the town of Queensbury. I am requesting temporary relief from the blacktop paving requirement until June 2009 due to the inclement weather at this time of year. If, by July 1, 2009,the property has not been paved to previously approved specifications, it is understood that the CO will be revoked until all required work is complete. Thank you for your consideration. Respectfully, Richard Bohl 11/04/2008 08:46 5184899199 PYRAMID PAGE 02/02 11/03/2008 14;57 4797011 COYNE ELECTRIC PAGE 02 1 N1 a . - i'. :.% if.. g 13 f rt a pl $ t�n e. G7r. g wff @ g y v s n p 0:q gTo . a ox ¢ I, � IM3 x i sR a ,o a Q I • hi" i P>: L , Zil n p.ro ill t'21 g"l' .�.. a �, x$ ¢ tem, ir , -.0 I ii i: og Y," 4 $ c I w 1 , _______ _ .,.. ; i g4: rg gO i p u e wi Fi. I i _, ,_ i E.At.- n :\ e'. A-(V. •'- t. 0 � '� I 1 yrs V o Rat17Commercial Final Inspection Report -.'ce No.: (518) 761-8256 Date Ins.ection res cst recei . Queensbury Building& Code Enforcement Arrive: ' = • _ D .art: am/.m 742 Bay Road, Queensb , NY 12804 Inspector s Initials: NAME: _ PE" IT#• v LOCATION: ��� _ /(�Ylux^ D• /7 / -4 — Av COMMENTS: Y lel NA Chimney/"B"Vent/ Direct Vent L_g_eation Plumbing Vent Through Roof 6"(Roof Complete J ./ Exterior Finish/Grade Complete 6 i tvalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks _ Stair Handrail 34 in.—38 in. / Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. -6 US-\> All Doors 36 in.w/Lever Handles/Panic Hardware,if required .44Exits At Grade Or Platform 36 (w)x 44" (1)/Canopy or Equiv. Gas Valve Shut-off Exposed& : -••• :" •ove Grade V l Floor Bathroom Watertight I •r Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 sq. ft. '/a Hour Corridor Doors &Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors _ Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond [Both sides] Active Listening System and Signage Assembly Space — � Final Electrical [� Site Plan/Variance required Final Survey,New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain o e oler Building Acce All S de- .y 20' /Dr' eabl face 20'wide _ Okay To Iss Tem,. : Permane C/O Okay To Issi '' L:\Building& Codes Forms\Building& Codes\Inspection Forms\Commercial Final Inspection Report.doc Commercial Final Inspection Rep Pe Po rt Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 6C)/1 1 I PERMIT#: ( yo /l LOCATION: ' <.;" .Sim, � -� c_ . DATE: (6i r 1 COMMENTS: Y Pd NIA 3 07 Chimney/'B"Vent I Direct Vent Location "' • Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6" in 10'or Equivalent t Interior/Exterior Guardrails 42 in. Platform I Decks Z O/2 / PL-rj Interior/Exterior Ballisters 4 in. Spacing Platform/Decks ("6, Stair Handrail 34 in.-38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors> 3000 sq. ft. �� 7/0 ).�� All Doors 36 in. w/Lever Handles/Panic Hardware, if required Exits At Grade Or Platform 36(w)x 44' (1)/Canopy or Equiv. }C1 Gas Valve Shut-off Exposed &Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve, Heat Trap I Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System ql/Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area S � Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 %doors 10% > 1000 sq. ft. '/,Hour Corridor Doors&Closers q/J // ° Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire �� Dampers/Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30" x 20"x 30" (h), Crawl Space Access 18" x 24° Smoke Vents Or Fan, if required /0/L/10 Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath I Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'/Driveable Surface 20'wide Okay To Issue Temp. or Permanent CIO Okay To Issue C/C _ L:\Building&Codes Forms\Building&Codesllnspection Forms\Conimercial Final Inspection Report.doc Revised January 7,2008 Sentinel Buildings P. O. Box 348 Albion, NE 68620 Erection Drawings for - RICHARD BOHL • PO BOX 7 •GLENMONT, NY 12077 RICHARD BOHL •SHERMAN AVE •QUEENSBURY, NY 12804 • B21451 Building Data Width ( ft ) = 35.0 Length ( ft ) =•140.0 Eave Height ( ft ) =•9.50 / 9.50 Roof Slope ( rise / 12 ) = 0.5 / 0.5 Dead Load ( psf ) = 2.2 Live Load ( psf ) =.20.0 Roof Snow Load ( psf ) = 60.0 Wind Speed ( mph ) ='90.0 Building Code = NYBC 02 Closure ='C Exposure =•C Importance - Wind =•1.0 Importance - Seismic = 1.0 Seismic Zone = - C Seismic Coeffiecient = 0.52 (S s*Fa) 00414.4.4.44 Designer = JLS o��.�G� w�<<� Draftsman = RRR .47/./ ��� o, \\,, vi/ Detailer = , �-pl. � eo ,* C iu February 17, 2006 \