Loading...
2006-184 el` TOWN OFQ UEENSBURY wom742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20060184 Date Issued: Thursday, October 04, 2007 This is to certify that work requested to be done as shown by Permit Number P20060184 has been completed. Location: 478 STATE ROUTE 149 Tax Map Number: 523400-278-019-0001-007-000-0000 Owner. FRANCIS & CAROLYN MARTINDALE Applicant: FRANCIS & CAROLYN MARTINDALE This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the i/ property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20060184 Application Number: A20060184 Tax Map No: 523400-278-019-0001-007-000-0000 Permission is hereby granted to: FRANCIS & CAROLYN MARTINDALE For property located at: 478 STATE ROUTE 149 in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Owner Address: Type of Construction FRANCIS & CAROLYN MARTIND/ 33 W STARBUCK Ln Residential Alteration FORT ANN, NY 12827-0000 Total Value Contractor or Builder's Name / Address Plans & Specifications Electrical Inspection Agency Value $10,000.00 $10,000.00 2006-184 375 SQ FT RESIDENTIAL ALTERATION $40.00 PERMIT FEE PAID - THIS PERMIT EXPIRES: Wednesday, April 11, 2007 (Ha longer period is required, an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T�wn o uee ur}� April 11, 2006 SIGNED BY for the Town of Queensbury. Director of Building & Code Enforcement OFFICE USE ONLY TAX MAP NO. a7 X . ( ') -- /-- 7 PERMIT NO. -2(306' 011/ FEES: PERMIT Lin ;u., RECREATION ENGINEERING (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: Jilc,c-Cr.� Oh d n`1'4, NER: /%rL_Q_ ADDRESS: L/9 k SyZtZz; az ./C,/9 ADDRESS: a e_ ask. i -)')ni, 10 ?8-- PHONE sus^PHONE NOS. ') ' g-3 dam„ PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:/i �ci, f) ONE: '79'DPS j LOCATION OF PROPERTY: 9i- • ' /. i SUBDIVISION NAME: �`6 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: C CHECK ALL THAT :z APPLY TO YOUR Z �� w C) d o LL PROJECT 0O Q a =" U0E L W Q � = adW : a oco oaiNz < < - ou. � SINGLE FAMILY 1 -- Josil,p TWO-FAMILY MULTI-FAMILY — (NO.of UNITS ) TOWNHOUSE0 6EICI ' BUSINESS OFFICE 1 ' ��"� . 'BORN( RETAIL- pF MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION�� COST:�J D/} OD . FUEL TYPE: AZ -(. ) , HEAT TYPE:J1D - Q/ *HOW MANY FIREPLACES S n t (S) � AND/OR WOODSTOVES(S): ZONING CATEGORY: //2 3 ARE THERE WETLANDS ON THIS SITE? /VCS IS THIS A HISTORIC SITE? hp PROPOSED USE OF BUILDING OR ADDITION: `� Qd e, � c / 1_ 1/d bz. *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: P BUILD! Gt CO(r �" AP—OVAL ZONING APPROVAL IG b DATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codesaqueensbury.net VISIT OUR WEBSITE FOR MORE INFORMATION www.queensburv.net Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ection request received: Queensbury Building& Code Enforcement Arrive: J S ir am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: al 1- n • NAME: A' PERMIT#: �, LOCATION: INSPECT ON: WI" TYPE OF STRUCTURE: N NIA COMMENTSFraming Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 /2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %i inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms /' in. // W i l�tJ ( ) �/I JP,if /Icy resi A 20 in. W . .ove/below grade 5.0 sf grade L:1Suetiemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive:a 11-4-• am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: (Z/ NAME: V,(T; PERMIT#: 0(0—0 LOCATION: LOS L )(_11 INSPECT ON: —/ . TYPE OF STRUCTURE: Y /N N/A COMMENTS raining ,/' Attic Access 22"x 30"minimum -w° L Jack Studs/Headers Bracing/Bridging r� Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (II) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: 0.,Zv am/pm Depart: am/prr► 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: /Q NAME: Com\11\e�c PERMIT #: riL0 ^ / O y LOCATION: 7 3 et` f i--/j INSPECT ON: y- /3- 0(a TYPE OF STRUCTURE: 1 htkir1/ Y N N/A AI*PVC: R-1, R-2, R-3, R-4 Drain/Vents CastIr n, Copper Drain/Vent/ Comm. Ai-, PI ing Vent/Vents in Place `. ough Plumbing/Nail Plates 1 '4 inch min. Drain Size / Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/ change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Hemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r uest received: Queensbury Building & Code Enforcement Arrive:- ' /5 am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: r7 4 NAME: \Q.AA� (\._ rc.. tAZ) PERMIT #: c=;100�' LOCATION: i '' t_ Jc4 (� , INSPECT ON: - ?, — Q TYPE OF STRUCTURE: piny)i Y N N/A PVC: R-1, R-2, R-3, R-4 Drain/Vents Cast Iron, Copper Drain I Vent/ Comm. L`� Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 1/: inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial proper, CPVC,Pex One and Two-Family _ f -,,,Ifisulation/Residential Check/ Commercial Check ISP Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly /No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Repoit.doc November 17,2003 7- r - 3 .\ . ?A-7 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: �1S7//6 Queensbury Building& Code Enforcement Arrive: 7 3 u am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:'0§-- NAME: lM 1 /1)I\w1 L-€ PERMIT #: 0 LOCATION: (,17 5- Si- AT /',-�;�,; p l--(9 INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2, R-3, R-4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/ Nail Plates 1 %z inch min. Drain Size Washing Machine Drain 2 inch m in. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes _ Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC, Pex One and Two-Family insulation/Residential Check/ Commercial Check +i Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 0b_, (ay - —_. ..... 2ti141__6 .1 ___._.._— t �f� TOWN OF QUEENBBURY 1 T. BUILDING, & _.,ODE DEP p 1� Cu1 a REVIEWED BYDAVE ii4:121'11611) _ r OWNOFQ�Utk;u,6,j,,;; iwl,pp,,,,,�,,� EVIL -. �T" 'ACU Ofi :)UI IIRII P A axamina:on,t------- cr�cl'li U ,__ .. :and sPeartabons � :I • Gr.GF: !rI 1 (__iiL [. ', Newyork:with atedige in I 1 R t�A stare. �h C�2ar pl�r;i'�� es ryl r \__. ` -N4,../ \,,.. :1-r-f. '\r"'' 1 i 'I i i .._Li_.._... ,_.. . •;-� Cl.o � .l�' .i. � 4) !`` E NCI nc;f. � J f • �a I— I! ,` 1 0!�-i V . Sx N) �c .:t , ' - 411 t , y i : & 3g- ,:441 (--, i) _, _ ____ __ ____,==...i.. . .. . . _. .. .. . . .. .. . 0, N__.1 �r 4 . . ,' ,, I'k� . _.____ :..FJ/F k F- y r —._ _ANOTiCE. ....._..... F n __, r� SMOKE DETECTORS ARE REQUIRED IN BEDROOMS, ca -I ADJACENT TO BEDROOMS, AND ON EACH FLOOR LEVEL c3 ►-,- INCLUDING CELLAR OR BASEMENT. ALL SMOKE r U - DETECTORS SHALL BE INTERCONNECTED ON ALL LEVELS. o c C7) 0 6 A> ~C L MO ETECTORS MUST BE BATTERY BACKUP. -< /CARBON MMIQXIDE DETECTOR REQUIRED OUTSIDE LOWEST SLEEPING LEVEL. Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive:3i!t( am/pm Depart: ar4/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:4 NAME: ,����< i� � — PERMIT #: 06- ty LOCATION: 9c'//( INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2, R-3,R-4 r,' /Vents Cast Iron, Copper Drain Vept)/ Comm. Plumbing Vent/Vents in Place V / Rough Plumbing/Nail Plates V 1 %z inch min. Drain Size tw,/ Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/ Commercial Check tf Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Nli /)//CJ ck,_ ck1( ' JJ FIk 7 /J L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: !1 Y- am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: 0, NAME: ft(-f 1 �� PERMIT#: 11, LOCATION: f DATE: TYPE OF STRUCTURE: Fr5 /�Ij Comments Yes I`® N/A , /�/ Building Number/Address visible from road - `T/// lQ7 Chimney Height/"B"Vent/Direct Vent Location • Fresh Air Intake 7" exp r/ 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete k7lie ' O� Platform at all exterior doors Guards at stairs, decks,patios more than 30 inches above grade 41111 ic). Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more 94„,/. "— • 7.— h 7I 62_ Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches 0 D . Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade / Interior privacy/trim/doors/main entrance 36 inches -ecy C CoA-h e Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing ---h Interior Smoke Detectors: Every level: Every Bedroom: l Outside every bedroom area: !/�S QclI % Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area �v k'9‘: Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq. ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq. ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0 [Temporary/Permanent j L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_]00405.doc Queensbury Building & Code Enforcement - Residential Final Inspection "'L c Office No.(518)761-8256 Arrive: 3:3 am/pm epart: am/pm 3% 3U Date Inspection request received: Inspector's Initials: _ NAME: r . fiZ 'L14- PERMIT#: I f LOCATION: Oz f f Yf DATE: 9 0 TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke De/e6tors: Every level: V Every Bedroo Outside every bedroom a: / Inter Connected: Battery backup: t/ Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping fmished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certificatio • equired Okay to issue C/C or /0[Temporary/ ermane L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc . . COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAy CERTIFICATE - ELECTRICAL APPROVAL 0 Permit No. / Cert. 3157 Cut-in Card No. Owner PlIfr4774-114-6— Location. qrg-• Installation Consisting of gee/ 7e/4f; lh294-172S 17/ 1/6:7 gei-A19 Installed By Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makinAti spections at any time, and if its rules are violated,the Company shall have the right t. rel) e ii Date 9-Z 7-a 7 INSPECTOR off 1,0 Member N.F.P.A.,I.A.E.I.