Loading...
CC-000225-2015 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 — Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000225-2015 Date Issued: Monday, June 6, 2016 This is to certify that work requested to be done as shown by Permit Number CC-000225-2015 has been completed. Tax Map Number: 288.16-1-1 Location: 1424 State Rte 9 Owner: Lake George Northway LLC Applicant: CMA This structure may be occupied as a: Commerical Alterations GH Bass By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the n property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. 3 0 N O O Lf) rn 0 a C 3 C �3 0 0 r z ai m 0 a� 0 d 0 N 0 LO 0 0 U 0 M x .06 II•i 1 TENANT: G.H. BASS & CO. 7401 BOONE AVENUE N BROOKLYN PARK, MN 55428 PH (763) 742-0603 FAX (763) 391-4004 BARBARA WENBERG barb.wenberg@amretailgroup.com PROJECT MANAGEMENT: CUSHMAN & WAKEFIELD-NORTHMARQ 3500 AMERICAN BLVD. WEST, SUITE 200 BLOOMINGTON -5 31 PH (952} 893--82'81- FAX (952 842-2205 SARAH REINITZ sarah.reinitz@cushwakenm.com 1 LANDLORD: LOD SOLUTIONS 115 N MAIN ST. SUITE B BEL AIR, MD 21014 PH (201) 669-7083 ROBIN GENOVESE robin.genovese@lodsolutions.com BUILDING DEPARTMENT: CITY OF QUEENSBURY BUILDING AND CODES 742 BAY RD. QUEENSBURY, NY 12804 PH (518) 761-8220 ARCHITECT: PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE, N. SUITE 208 MINNEAPOLIS, MN 55401 PH (612) 547-1300 FAX (612) 547-1301 ANTHONY JOHNSON ajohnson©cmarch.com MECHANICAL ENGINEER: EMANUELSON PODAS, INC 10401 BREN RD EAST, MINNETONKA, MN 55343 PH (952) 540-4029 FAX (952) 930-0777 MATT COLEMAN mcoleman©epinc.net ELECTRICAL ENGINEER: EMANUELSON PODAS, INC 10401 BREN RD EAST, MINNETONKA, MN 55343 PH (952) 540-4034 FAX (952) 930-0777 KEITH OBRIEN kobrien@epinc.net ® REFERENCE SYMBOLS I DEMO NOTE 0 FINISH TAG NO AAME ROOM/SPACE ® NUMBER ? DETAIL ENLARGEMENT FIXTURE TAG e T SPEC NOTE SCOPE OF WORK: TENANT FIT OUT OF EXISTING SHELL BUILDING FOR RETAIL SALES OF SHOES AND ACCESSORIES. AFF DOOR TAG DEC FURNITURE TAG AP ACCESS PANEL DEMO DEMOLITION ACC ACCESSIBLE DTL WALL SECTION � ELEVATION DATUM� REFERENCE • O GRID REFERENCE ° REFERENCE DIM DIMENSION O SIGN TYPE DISP WALL TYPE v ELEVATION OF DRINKING FOUNTAIN AL ALUMINUM '1 7 % REFERENCE APPD APPROVED, APPROVAL EA WINDOW TYPE APPROX APPROXIMATE EIFS PLAN NOTE ARCH ARCHITECTURAL 0 'EQUIPMENT TAG Q REVISION TAG ELEC WORK POINT BM BEAM EQ EQUAL BTWN BETWEEN EQUIP EQUIPMENT PROJECT SUMMARY EWC ELECTRIC WATER COOLER SCOPE OF WORK: TENANT FIT OUT OF EXISTING SHELL BUILDING FOR RETAIL SALES OF SHOES AND ACCESSORIES. AFF ABOVE FINISH FLOOR DEC DEGREE AP ACCESS PANEL DEMO DEMOLITION ACC ACCESSIBLE DTL DETAIL ACT ACOUSTICAL TILE DIA DIAMETER ADH ADHESIVE DIM DIMENSION ADJ ADJUSTABLE, ADJACENT DISP DISPENSER AHJ AUTHORITY HAVING JURISDICTION OF DRINKING FOUNTAIN AL ALUMINUM DS DOWNSPOUT APPD APPROVED, APPROVAL EA EACH APPROX APPROXIMATE EIFS EXTERIOR INSULATION ARCH ARCHITECTURAL LTG AND FINISH SYSTEM ACM ASBESTOS CONTAINING MATERIAL ELEC ELECTRICAL) BM BEAM EQ EQUAL BTWN BETWEEN EQUIP EQUIPMENT BLKG BLOCKING EWC ELECTRIC WATER COOLER BD BOARD EP ELECTRICAL PANELBOARD B. 0. BOTTOM OF EXG EXISTING CPT CARPET EXP EXPANSION CLG CEILING EJ EXPANSION JOINT CL CENTER LINE EXT EXTERIOR CT CERAMIC TILE FIN FINISH CLR CLEARANCE) FF FINISHED FLOOR COL COLUMN FE FIRE EXTINGUISHER CONC CONCRETE FEC FIRE EXTINGUISHER CABINET CMU CONCRETE MASONRY UNITS FP FIREPROOF, FIRE PROTECTION CONST CONSTRUCTION FLR FLOOR CONT CONTINUOUS FD FLOOR DRAIN CJ CONTROL JOINT FLUOR FLUORESCENT CG CORNER GUARD FRG FIBER REINFORCED GYPSUM CFLG COUNTERFLASHING FRP FIBER REINFORCED PLASTIC CTSK COUNTER SINK FRT FIRE RETARDANT TREATED CWN PROJECT MANAGEMENT FURN FURNISH OUTLETS AT LAKE GEORGE 1424 STATE ROUTE 9 LAKE GEORGE, NY 12845 BUILDING CODE SUMMARY: ALL DEMOLITION & WORK TO BE PERFORMED IN ACCORDANCE WITH ALL FEDERAL, STATE, COUNTY, AND LOCAL LAWS, REGULATIONS, RULINGS, CODES, ORDINANCES, REQUIREMENTS AND LANDLORD'S TENANT STORE DESIGN & CONSTRUCTION MANUAL. A. CODE: 2010 BUILDING CODE OF NEW YORK STATE 2010 PLUMBING CODE OF NEW YORK STATE 2010 MECHANICAL CODE OF NEW YORK STATE 2011 NATIONAL ELECTRICAL CODE 2010 FIRE CODE OF NEW YORK STATE 2010 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK B. OCCUPANCY GROUP: (CHAPTER 3) M (NON -SEPARATED USE) S (NON -SEPARATED USE) NON -SEPARATED USE PER SECTION 302.3.1 C. TYPE OF CONSTRUCTION: (CHAPTER 6) TYPE II -B D. AUTOMATIC SPRINKLER SYSTEMS: (SECTION 903) 1. SPRINKLERS REQUIRED: YES 2. SPRINKLERS PROVIDED: YES E. MEANS OF EGRESS: (CHAPTER 10) 1. EGRESS OCCUPANT LOAD: (TABLE 1004.1.2) OCCUPANCY FACTOR SF OCC. LOAD MERCANTILE 30 GROSS 4526 150 STORAGE 300 GROSS 1153 3 TOTAL 5,679 153 2. EGRESS WIDTH: (TABLE 1005.1) OCCUPANT LOAD FACTOR EGRESS WIDTH 153 0.15 22.95" 3. EGRESS WIDTH PROVIDED: 178" 4. COMMON PATH OF EGRESS TRAVEL (1014.3 /100' IF FULLY SPRINKLERED)75'-0" 5. DISTANCE TO EXIT INCREASE: (TABLE 1015.1) NO 6. MAXIMUM EXIT ACCESS TRAVEL DISTANCE: (TABLE 1016.1) 250'-0" 7. NUMBER OF EXITS REQUIRED (SECTION 1018.1) / PROVIDED: 2 / 3 F. PLUMBING FIXTURES: 1. SEPARATE PUBLIC TOILET FACILITIES PROVIDED BY THE MALL WITHIN 300 FEET OF TENANT SPACE PER SECTION 2902.3.3. A UNISEX TOILET ROOM IS PROVIDED IN TENANT SPACE FOR EMPLOYEE AND PUBLIC CONVENIENCE. G. NOTES: 1. FINISH CLASSIFICATION: "CLASS -C", FLAME SPREAD 76-200, SMOKE -DEVELOPED 0-450. 2. CONCEALED WOOD FRAMING/BLOCKING TO BE FIRE RETARDANT TREATED PER UL/ASTM. 3. NON-COMBUSTIBLE MATERIALS ONLY ABOVE FINISHED CEILING. 4. EXITS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY AND WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT. H. DEFERRED SUBMITTALS: 1. FIRE SPRINKLER AND/OR ALARM 2. EXTERIOR SIGNAGE ABBREVIATIONS NOT IN CONTRACT GA GAUGE GC GENERAL CONTRACTOR GB GRAB BAR GYP BD GYPSUM BOARD HDW HARDWARE HDWD HARDWOOD HT HEIGHT HDF HIGH DENSITY FIBERBOARD HC HOLLOW CORE HM HOLLOW METAL HB HOSE BIB HOR HORIZONTAL HR HOUR INCAN INCANDESCENT ID INSIDE DIAMETER INSUL INSULATION INT INTERIOR LAV LAVATORY LL LANDLORD, LEASE LINE LIN LINEAR LTG LIGHTING MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MDF MEDIUM DENSITY FIBERBOARD MTL METAL MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING MTD MOUNTED NOM NOMINAL NIC NOT IN CONTRACT N. 0. NUMBER NTS NOT TO SCALE 0. C. ON CENTER OPG OPENING OPP OPPOSITE OD OUTSIDE DIAMETER OFCI OWNER FURNISHED/ SSV CONTRACTOR INSTALLED OFOI OWNER FURNISHED/OWNER STL INSTALLED OH OVERHEAD OHCG OVERHEAD COILING GRILLE PT PAINT PNL PANEL PBD PARTICLE BOARD PTN PARTITION PLAM PLASTIC LAMINATE PL PLATE PLBG PLUMBING PLYWD PLYWOOD QTY QUANTITY QT QUARRY TILE RAD RADIUS REF REFERENCE/REFER TO REQ REQUIRED RES RESILIENT RD ROOF DRAIN RM ROOM RO ROUGH OPENING RB RUBBER BASE SCHED SCHEDULE SECT SECTION SHT SHEET SIM SIMILAR SWB SLOTTED WALL BOARD Sc SOLID CORE SPEC(S) SPECIFICATION(S) SF SQUARE FEET SS STAINLESS STEEL SSV STAIN, SEAL & VARNISH STD STANDARD STL STEEL STRUCT STRUCTURAL SUSP SUSPENDED TEMP TEMPERED, TEMPERATURE, TEMPORARY THK THICK(NESS) T&G TONGUE & GROOVE T.O. TOP OF T TREAD TYP TYPICAL LION UNLESS OTHERWISE NOTED VB VINYL BASE VCT VINYL COMPOSITION TILE VWC VINYL WALL COVERING VERT VERTICAL VIF VERIFY IN FIELD VTR VENT THROUGH ROOF WC WATER CLOSET WH WATER HEATER W/ WITH W/O WITHOUT WD WOOD KEY PLAN KRAFT PAPER INSULATION MUST BE COVERED BY NON-COMBUSTIBLE BARRIER NOTLCE FOAM INSULATION MUST P COVERED BY A 15 MINU' THERMAL RARPI LAYOUT OF HE GENERAL NOTES 1. SHADED AREAS INDICATED EXISTING CONSTRUCTION TO REMAIN. 2. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. FIELD VERIFY ALL DIMENSIONS AND SITE CONDITIONS. 3. ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD FINISH UNLESS OTHERWISE NOTED. 4. DIMENSIONS NOTED AS "HOLD" ARE CRITICAL. IF LAYOUT IS OFF, CONTACT ARCHITECT IMMEDIATELY PRIOR TO FRAMING. 5. DIMENSIONS NOTED AS "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES. 6. COLUMN CENTER LINES (GRID LINES) ARE SHOWN FOR DIMENSIONING. VERIFY EXACT LOCATIONS IN THE FIELD. 7. THE TENANT HANDBOOK AND STANDARD PROJECT DETAILS FOR THE MALL SHALL BECOME PART OF THE CONSTRUCTION DOCUMENTS AND ADHERED TO. COPIES CAN BE OBTAINED FROM THE LANDLORD. 8. BEFORE CONSTRUCTION START AND SUBMITTING BID PROPOSALS FOR THE WORK IN THESE SPECIFICATIONS AND DRAWINGS, EACH CONTRACTOR AND SUBCONTRACTOR SHALL EXAMINE THE SITE AND FAMILIARIZE THEMSELVES WITH ALL EXISTING CONDITIONS BEFORE PROCEEDING. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF A MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR LACK OF KNOWLEDGE OF EXISTING CONDITIONS. IN CASE OF ANY INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS, THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY AND THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF SUCH DISCREPANCIES. NOT REPORTING ANY SUCH UNSUITABLE CONDITION WILL CONSTITUTE ACCEPTANCE OF ALL CONDITIONS BY CONTRACTOR AND/OR SUBCONTRACTOR AND ASSOCIATED COSTS. 4. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS IS IN DOUBT, OR WHERE THERE APPEARS TO BE AN ERROR ON THE DRAWINGS OR A DISCREPANCY BETWEEN THE DRAWINGS AND FIELD CONDITIONS, THE ARCHITECT AND TENANT SHALL BE NOTIFIED AS SOON AS POSSIBLE. IF THE CONTRACTOR PROCEEDS WITH THE WORK SO AFFECTED WITHOUT INSTRUCTIONS FROM THE ARCHITECT AND TENANT, THE CONTRACTOR SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECTS. THIS INCLUDES ERRORS IN THE SPECIFICATIONS AND NOTATION ERRORS ON THE DRAWINGS WHERE DOUBTFUL OF INTERPRETATION. FAILURE TO GIVE NOTICE WILL CAUSE THE GC TO BE HELD RESPONSIBLE FOR THE RESULT OF ERRORS, DISCREPANCIES OR OMISSIONS AND THE COST OF RECTIFYING THE SAME. 5 SUBCONTRACTORS ARE RESPONSIBLE FOR THE T IR WORK AND ACCEPTANCE OF '} CONDITIONS PRIOR TO BEGINNING WORK. i a 4. NO HAZARDOUS MATERIALS, LIQUIDS OR CHEMICALS SHALL BE STORED OR USED WITHIN THE - SUBJECT BUILDING AS TO REQUIRE A HAZARDOUS CLASSIFICATION PER APPLICABLE CODE. 5. SWITCHES AND CONTROLS FOR LIGHTS, VENTILATION, FIRE ALARMS, ETC. MUST BE PLACED NO MORE THAN 48" AFF. [ On) ;; , j' 6. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE CONDITIONED, USED, APPLIED, Y+ INSTALLED, CONNECTED, ERECTED, AND CLEANED IN ACCORDANCE WITH THE MANUFACTURERS 1 t WRITTEN SPECIFICATIONS OR INSTRUCTIONS AND STANDARD INDUSTRY GUIDELINES. i ALL FINISH WOOD SHALL BE KILN -DRIED MILL QUALITY FINISH AND ALL WOOD SHALL RECEIVE A FIRE -RETARDANT COATING OR TREATMENT, AS REQUIRED. z' 8. GC IS RESPONSIBLE FOR MAINTAINING STRUCTURAL INTEGRITY OF LANDLORDS STRUCTURE AND i'I 1 PROTECT ELEMENTS AND PERSONNEL FROM DAMAGE AND HARM. CEASE OPERATIONS AND NOTIFY ........ yi OWNER IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. TAKE PRECAUTIONS T TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUME OPERATIONS UNTIL SAFETY IS RESTORED. 9. GC IS RESPONSIBLE FOR MAINTAINING FIRE RATED ASSEMBLIES THROUGHOUT THE SPACE DURING III n..v DEMOLITION AND CONSTRUCTION. REPAIR/REPLACE ANY FIRE PROOFING AND ASSEMBLIES WITH EXACT MATCHING MATERIALS AND RATINGS. 10. ALL PENETRATIONS THROUGH FIRE RESISTIVE FLOORS, WALLS OR SHAFT WALLS SHALL BE PROTECTED 4 BY MATERIALS AND INSTALLATION METHODS THAT CONFORM TO U.L. STANDARDS FOR FIRESTOP SYSTEMS. THE GC SHALL SUBMIT SHOP DRAWING DETAILS WHICH SHOW COMPLETE CONFORMANCE TO THE U.L. LISTING TO THE ARCHITECT. 1 11. NOTIFY ARCHITECT IMMEDIATELY AS TO SIZE AND LOCATION OF ANY EXISTING MALL EXPANSION > p- r4 } +•.,a-�� I' ti I JOINTS LOCATED IN DEMISING WALLS, FLOOR, OR CEILING CONSTRUCTION. 12. GC SHALL KEEP ALL HANDBOOKS, PAPERWORK, AND KEYS IN A MARKED ENVELOPE; ALL KEYS TO e BE TAGGED WITH PROPER LOCATIONS. THIS ENVELOPE SHOULD BE TURNED -OVER TO THE STORE -# OPERATIONS MANAGER WITH CERTIFICATE OF OCCUPANCY. - SHEET INDEX x r t G.H.BASS & CO. Q2 G1 TITLE SHEET I COPY --SPACE- 7 FILE COPY '# Di G2 RESPONSIBILITY SCHEDULE/SPECIFICATIONS ARCHITECTURAL TOWN OF QUEENSBURY Q D1 DEMOLITION PLAN NUIIUC At!- WaYMRE SHALL COMPLYLEVER HANDLES REQUIRED FIRE MARSHAt,S OFFICE D1.1 DEMOLITION REFLECTED CEILING PLAN ON ALL PASSAGE DOORS WT t CPAPTER 90 OF T1tE FIFE CODE OF NY $. REVIEWED BY . ` Q A 1 F L 0 0 R PLAN WHETHER INTERIOR OR Nom: THE USE OF A KEY OPEEPATED OR THUMO ' � EXTERIOR DOORS DATE ��� NORTH A1.1 DETAILS AND SCHEDULES TURN DEVICE IS NOT P91AH]ITED. COMMENTS Q A2 REFLECTED CEILING PLAN A2.1 REFLECTED CEILING PLAN DETAILS GH Bass 1424 State Route 9 Commerical Alt. Revised plans PATRICK G. BLEES architecture . planning = interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: ITIS A MOLAT10N OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK G.,,BLEES„ ARCHITECT SIGNATURE 10/9/15 DATE ISSUED 031848-1 REG. NO OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: TITLE SHEET REVISIONS: NO: DATE: BY: PROJECT NO: 15101,020 DRAWN BY: OMC G 1 COPYRIGHT PATRICK G. BLEES, AIA 201F' ' I i I A. GENERAL LIABILITY ® G $2,000,000.00 UON IN WALL CAVITY AS IL STOREFRONT ILLUMINATED SIGN SSORIES, COAT _ 2. SECURITY ALARM -OFF HOURS HATCH ADJ WALL, - COMMERCIAL GENERAL LIABILITY - OCCURRENCE - TENANTS & CC'S PROTECTION a • G GI B. B. AUTOMOBILE LIABILITY C. G N 5. FRP WALL PANELS 1NELS AND ACCESSORIES. E. BLADE SIGN Rk N - ANY AUTO - HIRED AUTOS m } B. BACKWRAP FIXTURE ASSEMBLY C. _ WORKERS COMPENSATION & N G $500,000.00 0] • A. EMPLOYER LIABILITY PLANS FOR LOCATIONS zt=n� 00 w La B. TOILET PAPER DISPENSER D. o \ PAPER TOWEL DISPENSER G$5.000.000.00 D. MIRROR E. E. aFiZH w � N AM RETAIL GROUP dba, G.H. BASS & CO , 7401 BOONE AVE N, BROOKLYN PARK, 6 IT ITEM SEE DOOR SCHEDULE. ? DESCRIPTION MN 55428 - CONST DEPT B. STEEL CORNER GUARDS r 01 GENERAL REQUIREMENTS F. ADDITIONAL INSURED "J" TRIM AT ALL EDGES. BOTTOM MOUNTED 0'-7" AFF. ATTACH WITH MASTIC G 06 WOOD, PLASTICS t 1. INSURANCE G CERTIFICATE OF INSURANCE AS REQUIRED BY TENANT AND/OR LANDLORD. PROVIDE INSURANCE COVERAGE 1. ROUGH CARPEN' DTH X 6'-0" HIGH - PILASTER MIRRORS. MATCH MIRROR WIDTH INCLUDING 13 SPECIAL CONSTRUCTION EXACTLY AS OUTLINED IN BID AND CONTRACT DOCUMENTS TO TENANT. TENANT SHALL 2. WOOD BLOCKING 1 r 51/8" THICK TYPE "X", PROVIDE LEVEL 2 FINISH AT CONCEALED LOCATIONS ONLY, NOT PERMIT SAID CONTRACTORS TO COMMENCE ANY WORK UNTIL REQ INSURANCE _ PROVIDE LEVEL 4 FINISH ELSEWHERE. PROVIDE CONTROL JOINTS AT 30'-0" OC MAX _ INCLUDED IN BID PACKAGE DOCUMENTS. 07 THERMAL & MOISTURE PROTEC HAS BEEN OBTAINED AND CERTIFICATES EVIDENCING COVERAGE HAVE BEEN DELIVERED UL PER EXG DECK CONDITION. 3. FIRE ALARM PATCH/REPLACE AS REQUIRED PRIOR TO INSTALLATION OF NEW FINISHES. MAINTAIN 14 CONVEYING SYSTEMS 1. TO TENANT. POLICIES SHALL BE WRITTEN WITH INSURERS ACCEPTABLE TO TENANT. 3. PLYWOOD PERMITS AND FEES 1. PLUMBING G GI MAT BACK SURFACE TO RESIST MOLD & MILDEW AT TOILET ROOMS & "WET" AREAS. A. STUB -INS 4 WOOD TRIM 0 U U eQ i T C� m RESPONSIBILITY SCHEDULE DESCRIPTION FIRE RETARDANT TREATED FIRE RETARDANT TREATED WOOD BLOCKING, NAILERS, SHIP, REQUIRED AT WALL MOUNTED AND STORAGE FIXTURES, AC HANGERS, GRAB BARS, ETC. PAINT EXPOSED BLOCKING 1 3/4" FIRE RETARDANT TREATED CDX _ HARDWOOD TRIM CONFORMING TO AWI STANDARDS. SPA, PAINT TO MATCH ADJ WALL LON. ALL WOOD TRIM TO WHITE, PEBBLE FINISH FIBERGLASS REINFORCED PLASTIC C/S GROUP - SERIES VA -200 - WHITE #949. 1 1/2 PER MFG REQUIREMENTS WITH MFG SUPPLIED TAPE. PF RECOMMENDATIONS. APPLY TO 8'-0" AFF ON ALL OUT RECEIVING PATH IN FOYERS CORRIDORS AND STOCKROC COLD ROLLED STEEL CORNER GUARDS. REFER TO FIXTE AND SIZES. PREPARE SURFACES PER FIXTURE VENDOR WITH #8 SCREWS PROVIDED BY GC. APPLY TO.ALL OU' ROOM FOYER PER PLANS. AS REQUIRED BY EACH TRADE. A. GENERAL LIABILITY ® G $2,000,000.00 UON IN WALL CAVITY AS A. STOREFRONT ILLUMINATED SIGN SSORIES, COAT _ 2. SECURITY ALARM -OFF HOURS HATCH ADJ WALL, - COMMERCIAL GENERAL LIABILITY - OCCURRENCE - TENANTS & CC'S PROTECTION A. SECURITY SYSTEM KEY PAD • G GI B. B. AUTOMOBILE LIABILITY C. G 1 000 000.00 5. FRP WALL PANELS 1NELS AND ACCESSORIES. E. BLADE SIGN Rk 2. - ANY AUTO - HIRED AUTOS 6. CORNER GUARDS B. BACKWRAP FIXTURE ASSEMBLY C. _ WORKERS COMPENSATION & C. MERCHANDISE UNITS - FLOOR G $500,000.00 A. VINYL CORNER GUARDS • A. EMPLOYER LIABILITY PLANS FOR LOCATIONS MAKE WEATHERTIGHT. PROVIDE RATED DOOR FRAME AND HARDWARE AS REQUIRED, F :OMMENDATIONS. MOUNT B. TOILET PAPER DISPENSER D. EXCESS LIABILITY MINIMUM PAPER TOWEL DISPENSER G$5.000.000.00 D. MIRROR E. E. CERTIFICATE HOLDER 5. G AM RETAIL GROUP dba, G.H. BASS & CO , 7401 BOONE AVE N, BROOKLYN PARK, 6 MOP HOLDER / SHELF T T SEE DOOR SCHEDULE. TIG SEE DOOR SCHEDULE. MN 55428 - CONST DEPT B. STEEL CORNER GUARDS 1/4" THICK POLISHED ELECTROLYTIC PLATE GLASS MIRROR WITH POLISHED EDGES & F. ADDITIONAL INSURED "J" TRIM AT ALL EDGES. BOTTOM MOUNTED 0'-7" AFF. ATTACH WITH MASTIC G AS PER LANDLORD CRITERIA _ AND APPLY CLEAR SILICONE SEAL AT PERIMETER. G. HANGER BIN G. CERTIFICATE OF INSURANCE G PROVIDE TO TENANT AND LANDLORD OFFICE PRIOR TO CONST START WITH LIMITS AND DTH X 6'-0" HIGH - PILASTER MIRRORS. MATCH MIRROR WIDTH INCLUDING 13 SPECIAL CONSTRUCTION PILASTER WIDTH. 1. SPRINKLER SYSTEM LIABILITIES OUTLINED BY LANDLORD IN LEASE EXHIBITS, CERTIFICATE FORM TO BE 51/8" THICK TYPE "X", PROVIDE LEVEL 2 FINISH AT CONCEALED LOCATIONS ONLY, G G PROVIDE LEVEL 4 FINISH ELSEWHERE. PROVIDE CONTROL JOINTS AT 30'-0" OC MAX _ INCLUDED IN BID PACKAGE DOCUMENTS. 07 THERMAL & MOISTURE PROTEC UL PER EXG DECK CONDITION. 3. FIRE ALARM PATCH/REPLACE AS REQUIRED PRIOR TO INSTALLATION OF NEW FINISHES. MAINTAIN 14 CONVEYING SYSTEMS 1. CAULKING/SEALANTS 15 MECHANICAL 2. PERMITS AND FEES 1. PLUMBING G GI MAT BACK SURFACE TO RESIST MOLD & MILDEW AT TOILET ROOMS & "WET" AREAS. A. STUB -INS A. BUILDING PERMIT AND FEES PROTECT SLAB, CLEAN/WASH AND REMOVE PAINT, ADHESIVE, DRYWALL COMPOUND, G - AS REQUIRED BY AHJ, LANDLORD AND/OR TENANT. 2. WATERPROOF MEMBRANE B. BUILDING PLAN CHECK FEE ;T1 •PROVIDE G AS REQUIRED BY AHJ, LANDLORD AND/OR TENANT. 3. BATT INSULATION 4. MOP SINK C. SIGN PERMIT 5. WATER BOTTLE STATION T AS REQUIRED BY AHJ, LANDLORD AND/OR TENANT. 4. BOARD INSULATION GYPSUM BOARD SEE 09/1, PREPARE FOR PAINT FINISH. D. SIGN PLAN CHECK FEE SG RADAR SERI S 2120 X2 X5/8- -CL "- EG LAR DG -WHIT ILES & T AS REQUIRED BY AHJ, LANDLORD AND/OR TENANT. 5. E.I.F.S. E. OTHER GI ALL OTHER PERMITS & FEES REQUIRED BY AHJ, LANDLORD AND/OR TENANT. 6. MOISTURE BARRIER 16 ELEC ICAL 3. INSPECTIONS AND FEES 1. STUB -IN GI AS REQUIRED BY AHJ, LANDLORD AND/OR TENANT. 7. VAPOR BARRIER VERIFY SUITABILITY OF SURFACES TO RECEIVE PAINT. STARTING CONSTITUTES 4. PROJECT SUPERVISION/COORDINATION ACCEPTANCE OF SUBSTRATE TO ACCEPT PAINT, GC TO CORRECT ANY GI FULL TIME ON-SITE SUPERVISOR FOR ALL ASPECTS OF CONSTRUCTION WORK, 8. FLASHING/SHEET METAL ADJACENT MATERIALS, FINISHES, AND FIXTURES. REMOVE SPLATTERING AND LEAVE 6. DISTRIBUTION IN TENANT SPACE AREA IN CLEAN FINISHED CONDITION. SEE FINISH SCHEDULE FOR ALL PAINT COLORS INCLUDING BUT NOT LIMITED TO INSTALLATION METHODS, TECHNIQUES, SEQUENCES, 9. ROOFING 8. LIGHT FIXTURES APPLIED PAINT TO BE DRY FALL. A. INTERIOR - GENERAL & TRAC T GI PROCEDURES AND COORDINATION OF ALL TRADES. 10. SPRAYED -ON FIREPROOFING "r 5. CODES AND STANDARDS COST TO TENANT. STARTING WORK CONSTITUTES ACCEPTANCE OF SUBSTRATE G ALL WORK SHALL COMPLY WITH CURRENT FEDERAL, STATE AND LOCAL CODES, LAWS, 08 OPENINGS -DOORS &WINDOWS MEASURES TO PROTECT ADJACENT MATERIALS, FINISHES, & FIXTURES, CLEAN ALL 10. BUZZER SURFACES OF EXCESSIVE ADHESIVE, REMOVE SPLATTERING AND LEAVE AREA IN A ORDINANCES, REGULATIONS AND LANDLORD CRITERIA AS IN THE PERFORMANCE OF THE 1. DOOR & FRAME CONTRACT. GC SHALL BE HELD TO BE FULLY INFORMED OF AFORESAID REGULATIONS. _ DEVIATIONS FROM PLANS OR SPECIFICATIONS AND ADDITIONAL WORK NECESSARY TO MEET REQUIREMENTS SHALL BE MADE BY GC WITHOUT EXTRA COST TO TENANT. 2. STOREFRONT ENTRY DOORS (E 6. SITE CONDITIONS AND DIMENSIONS G FIELD VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO BID. 7. PROTECTION OF WORK G GI CARE SHALL BE TAKEN TO PROTECT ALL MATERIALS AND COMPLETED WORK. GC SHALL BE RESPONSIBLE FOR ALL COORDINATION & COSTS WITHOUT EXTRA COST TO TENANT. 3. STOREFRONT GLAZING SYSTEM 8. RECEIPT OF MATERIALS G RECEIVE AND VERIFY ALL TENANT SUPPLIED MATERIALS AND EQUIPMENT. DOCUMENT 4. ACCESS PANEL ANY SHORTAGES AND DAMAGE ON RECEIVING TICKETS AND REPORT TO TENANT'S PROJECT MANAGER IMMEDIATELY UPON RECEIPT. OBTAIN COPIES OF ALL SIGNED RECEIVING TICKETS AND SUBMIT TO TENANT ON A WEEKLY BASIS. 5. DOOR HARDWARE 9. ALTERNATES (SUBSTITUTIONS) G G IT WILL BE ASSUMED THE TOTAL BID IS BASED UPON MATERIALS SPECIFIED. A. CYLINDER LOCK SUBSTITUTIONS MAY BE OFFERED AND SUBMITTED IN WRITING AS OUTLINED IN THE B. OTHER SPACE PROVIDED ON BID PROPOSAL FORM. SUBSTITUTIONS MUST HAVE WRITTEN 6, MIRRORS APPROVAL OF TENANT'S PROJECT MANAGER BEFORE BEING USED. 10. WARRANTIES AND BONDS G PROVIDE TENANT WITH LABOR AND MATERIAL WARRANTIES AND SERVICE CONTRACTS _ FROM ALL SUBCONTRACTORS AND EQUIPMENT & MATERIAL MANUFACTURERS. THESE A. MIRROR 1 WARRANTIES SHALL BE IN EFFECT FOR A PERIOD of NO LESS THAN ONE (1) YEAR B. MIRROR 2 FROM CONSTRUCTION COMPLETION. PROVIDE A PERFORMANCE BOND AND A LABOR C. MIRROR 3 AND MATERIALS BOND. FINAL PAYMENT OF TEN PERCENT (107) OF THE CONTRACT - a AMOUNT WILL BE WITHHELD UNTIL FINAL NOTARIZED, UNCONDITIONAL LIEN WAIVERS D. MIRROR 4 ARE RECEIVED._ 09 FINISHES 11. CUTTING AND PATCHING G G CUT AND PATCH AS REQUIRED TO COMPLETE WORK. MAKE ANY REPAIRS FOR DAMAGE 1. GYPSUM BOARD CAUSED DURING CUTTING OF WORK WITHOUT ADDITIONAL COST TO TENANT. 12. TRASH REMOVAL & DUMPSTERS G G PROVIDE AND PAY FOR WASTE CONTAINER AND REMOVAL SERVICE FOR ALL REFUSE AND WASTE MATERIALS. 13. CLEAN UP _ GIGI GIG DAILY REMOVAL OF WASTE AND SWEEP CLEANING DURING CONSTRUCTION. EACH 2. GYPSUM BOARD -EXISTING TRADE IS RESPONSIBLE FOR CLEAN-UP & REMOVAL OF OWN CONSTRUCTION WASTE FROM SITE. PROVIDE THOROUGH PROFESSIONAL CLEAN-UP OF ENTIRE SPACE & 3. GYPSUM BOARD -MOISTURE RE ADJACENT SERVICE/PUBLIC AREAS AT PROJECT COMPLETION, READY TO OPEN FOR BUSINESS. VACUUM, SWEEP, MOP, WASH, & CLEAN ALL SURFACES INCLUDING GLASS 4. FLOOR AND MIRRORS. HVAC GRILLES DIFFUSERS TO BE WASHED AND FILTERS REPLACED. A. CONCRETE WAX - WAXI 14. TEMPORARY FACILITIES A. UTILITIES -GAS /WATER /ELEC G G AS REQUIRED, COORDINATE WITH LANDLORD AND UTILITY COMPANIES. _ ' B. VOICE/DATA-TELEPHONE G G PROVIDE ONE (1) TEMP TELEPHONE ON JOBSITE AT CONSTRUCTION START AND NOTIFY B. VINYL COMPOSITION TILE - TENANT'S PROJECT MANAGER OF NUMBER UPON INSTALLATION. COORDINATE WITH LANDLORD AND PHONE COMPANY 5. CEILING C. FIRE AND SMOKE DETECTION, G G PER AHJ AND LANDLORD CRITERIA. A. OPEN To STRUCTURE PROTECTION, NOTIFICATION B. HARD SURFACE D. CONSTRUCTION BARRICADE G G IF REQUIRED, PROVIDE AND PAY FOR DUSTPROOF STOREFRONT BARRICADE PER C. SSP ND D AC USICL E LANDLORD CRITERIA. REMOVE AT CONSTRUCTION COMPLETION, COORDINATE REMOVAL '1 ACTT WITH AHJ & LANDLORD. 02 EXISTING CONDITIONS -SITE WORK 6. BASE 1. DEMOLITION G G AS REQUIRED TO CONSTRUCT SPACE AS DETAILED. VERIFY ITEMS TO BE SALVAGED, A. VINYL - Bt/ B2 3 -9 REUSED OR REMOVED FROM SITE WITH TENANT. 7. PAINT aai 2. SITE PAVING & SIDEWALK • _ V) 3. SITE U ILITIES G 0 IN TE PERMANENT SER IC M TERS, & F AL CONNECTIONS, E EP DWGS. N 4. CORE DRILL SLAB G G AS REQUIRED FOR UND R -SLAB PLUMBING COORDINATE ORK WITH _ o LANDLORD'S ON-SITE REPRESENTATIVE. SEE MECH DWGS AND DIVISION 1 0 "03 CONCRETE" FOR PATCHING REPAIR 0 03 CONCRETE LO 1. SAND PAD • - 2. VAPOR BARRIER • - - 03 03 3. REINFORCING FABRIC • _ B. WALL COVERING - WC1 q) 0 4. CONCRETE SLAB • G PREPARE SURFACE FOR NEW FINISHES, 5. POURED CONCRETE GIG INFILL AS REQUIRED AT SLAB TO MATCH EXG CONDITIONS PER LL CRITERIA. a` 6. FLOOR PATCH UNDERLAYMENT TOPPING G G "ARDEX FEATHER FINISH" AS REQUIRED AT AREAS OF FLOOR PATCH REPAIR AND TO y ENSURE FLUSH FINISH FLOOR INSTALLATIONS. 0 7. TILT -UP PANELS WALLS • L L EXISTING EXTERIOR WALLS BY LANDLORD, SEE WALLTYPES. j 04 MASONRY rn 1. CONCRETE BLOCK • - 0 2. BRICK • - 3. SURFACE PREPARATION CLEANING G CLEAN AND PREPARE SURFACES FOR NEW FINISHES. 0 05 METALS } 1. STRUCTURAL STEEL z A. SHELL BUILDINGGC • TO MAINTAIN FIRE RATING AS REQUIRED. v � B. OTHER G G ANGLES, TUBES, PLATES, CHANNELS PER DWGS SHALL CONFORM TO ASTM A36 & HAVE SHOP COAT PRIMER EQUAL TO "TENMAC CO. 99-G". 2. COLD -FORMED METAL FRAMING I -DIETRICH" / "MARINO", UNLESS OTHERWISE NOTED. A. DEMISING WALL(S) • d B. PARTITION & SOFFIT/CLG FRAMING G G 3 5/8" X 25 GA STUDS, TRACKS, RUNNERS, ® 16" O.C., 6" AT PLUMBING WALLS, LION. o C. FURRING G G 20 GA STUDS, HAT CHANNELS, Z -CHANNELS, ETC ® 16" O.C. 0 3. MISCELLANEOUS G G UNISTRUT, THREADED ROD, ETC PER DWGS. 4. METAL REVEAL N/A r : ;t Lt 5. METAL CASH ,WRAP SOFFIT FRAME N/A 6 TRANSITION/REDUCFR STRIPS GIG SCHLUTER SYSTEMS TRANSITION/REDUCER STRIP_ W/ SATIN ANODIZED ALUMN FINISH. 0 U U eQ i T C� m RESPONSIBILITY SCHEDULE DESCRIPTION FIRE RETARDANT TREATED FIRE RETARDANT TREATED WOOD BLOCKING, NAILERS, SHIP, REQUIRED AT WALL MOUNTED AND STORAGE FIXTURES, AC HANGERS, GRAB BARS, ETC. PAINT EXPOSED BLOCKING 1 3/4" FIRE RETARDANT TREATED CDX _ HARDWOOD TRIM CONFORMING TO AWI STANDARDS. SPA, PAINT TO MATCH ADJ WALL LON. ALL WOOD TRIM TO WHITE, PEBBLE FINISH FIBERGLASS REINFORCED PLASTIC C/S GROUP - SERIES VA -200 - WHITE #949. 1 1/2 PER MFG REQUIREMENTS WITH MFG SUPPLIED TAPE. PF RECOMMENDATIONS. APPLY TO 8'-0" AFF ON ALL OUT RECEIVING PATH IN FOYERS CORRIDORS AND STOCKROC COLD ROLLED STEEL CORNER GUARDS. REFER TO FIXTE AND SIZES. PREPARE SURFACES PER FIXTURE VENDOR WITH #8 SCREWS PROVIDED BY GC. APPLY TO.ALL OU' ROOM FOYER PER PLANS. AS REQUIRED BY EACH TRADE. •G G 10 SPECIALTIES ® 1. SIGNAGE UON IN WALL CAVITY AS A. STOREFRONT ILLUMINATED SIGN SSORIES, COAT _ 2. SECURITY ALARM -OFF HOURS HATCH ADJ WALL, A. SECURITY SYSTEM KEY PAD • G GI B. NON -ILLUMINATED SIGN .E FASTENERS AND C. ADA/ACCESSIBILITY SIGNAGE MITER CUT DON. D. SERVICE DOOR SIGNAGE 1NELS AND ACCESSORIES. E. BLADE SIGN Rk 2. FIRE EXTINGUISHERS ;ORNER GUARD, INSTALL 1 3/4' THICK DOOR, PROVIDE NECESSARY ACCESSORIES AT EXTERIOR LOCATIONS TO B. BACKWRAP FIXTURE ASSEMBLY ARE SURFACES PER MFG MAKE WEATHERTIGHT. PROVIDE RATED DOOR, FRAME AND HARDWARE AS REQUIRED C. MERCHANDISE UNITS - FLOOR E CORNERS ALONG 3, TOILET ROOM ACCESSORIES • A. GRAB BARS PLANS FOR LOCATIONS MAKE WEATHERTIGHT. PROVIDE RATED DOOR FRAME AND HARDWARE AS REQUIRED, F :OMMENDATIONS. MOUNT B. TOILET PAPER DISPENSER )E CORNERS IN FITTING C. PAPER TOWEL DISPENSER G GI D. MIRROR E. SOAP DISPENSER 5. WALL STANDARDS AND SHELF 6 MOP HOLDER / SHELF •G G AT "WET AREAS PER LANDLORD cKUEMA ELECTRICAL ® _ 11 EQUIPMENT • _ 1. SECURITY PEDESTALS • _ 2. SECURITY ALARM -OFF HOURS 01 A. SECURITY SYSTEM KEY PAD • G GI REINSTATE DISTURBED PER DRAWINGS AND LANDLORD CRITERIA. 3. CASH REGISTER -POS • - 4. TRAFFIC COUNTER (WIRED) • G G I EXISTING TO REMAIN. USE LANDLORD GC TO PATCH AS REQUIRED. 12 FURNISHINGS • _ 1. SALES AREA Rk CONTACT LOCAL TELEPHONE COMPANY. SEE ELECTRICAL SHEETS. A. CASHWRAP FIXTURE ASSEMBLY • G G 1 3/4' THICK DOOR, PROVIDE NECESSARY ACCESSORIES AT EXTERIOR LOCATIONS TO B. BACKWRAP FIXTURE ASSEMBLY OF REAR DOOR ® 5'-0" AFF. SINGLE CHIME FROM MAKE WEATHERTIGHT. PROVIDE RATED DOOR, FRAME AND HARDWARE AS REQUIRED C. MERCHANDISE UNITS - FLOOR ROOM. DOUBLE CHIME FROM REAR DOOR TO RING PER DOOR SCHEDULE. D. MERCHANDISE UNITS - WALL • ALUMINUM GLASS PROVIDE NECESSARY ACCESSORIES AT EXTERIOR LOCATIONS TO E. CART, CHAIRS MAKE WEATHERTIGHT. PROVIDE RATED DOOR FRAME AND HARDWARE AS REQUIRED, F SEE DOOR SCHEDULE. G. B LINE STANDARD =XT 01 1 ALUMINUM FRAMING SYSTEM WITH CLEAR, INSULATED GLASS TEMPERED AS REQUIRED). G GI 1 -HOUR RATED "J. L. INDUSTRIES" MODEL FRC. COORDINATE EXACT SIZE LOCATION & A. STORAGE .SYSTEM QUANTITIES WITH ON-SITE CONDITIONS, LANDLORD & TENANT. ALLOW CLEARANCES B. MANAGERS DESK FOR FULL OPERATION OF ACCESS PANEL, PAINT TO MATCH ADJACENT FINISHES, C. EMPLOYEE DESK D. SHELVING SYSTEM T T SEE DOOR SCHEDULE. TIG SEE DOOR SCHEDULE. E. BULLETIN BOARD 1/4" THICK POLISHED ELECTROLYTIC PLATE GLASS MIRROR WITH POLISHED EDGES & "J" TRIM AT ALL EDGES. BOTTOM MOUNTED 0'-7" AFF. ATTACH WITH MASTIC F. HARDWARE BIN AND APPLY CLEAR SILICONE SEAL AT PERIMETER. G. HANGER BIN VADHESIVE DE X 6'-0" HIGH - FITTING ROOMS AND FITTING ROOM VESTIBULES H. LOCKERS DTH X 6'-0" HIGH - PILASTER MIRRORS. MATCH MIRROR WIDTH INCLUDING 13 SPECIAL CONSTRUCTION PILASTER WIDTH. 1. SPRINKLER SYSTEM IXTURE ENDCAP MIRRORS. 51/8" THICK TYPE "X", PROVIDE LEVEL 2 FINISH AT CONCEALED LOCATIONS ONLY, G G PROVIDE LEVEL 4 FINISH ELSEWHERE. PROVIDE CONTROL JOINTS AT 30'-0" OC MAX OR AS REQUIRED. SEAL TIGHT TO DECK FOR 1 -HOUR RATING WHERE REQUIRED PER 2. SMOKE DETECTORS UL PER EXG DECK CONDITION. 3. FIRE ALARM PATCH/REPLACE AS REQUIRED PRIOR TO INSTALLATION OF NEW FINISHES. MAINTAIN 14 CONVEYING SYSTEMS 6IG.Gj EXISTING RATINGS IF APPLICABLE. 15 MECHANICAL STANT 5/8" THICK TYPE "X", MOISTURE -RESISTANT CORE & COATED INORGANIC FIBERGLASS 1. PLUMBING G GI MAT BACK SURFACE TO RESIST MOLD & MILDEW AT TOILET ROOMS & "WET" AREAS. A. STUB -INS B. GAS METER G GI PROTECT SLAB, CLEAN/WASH AND REMOVE PAINT, ADHESIVE, DRYWALL COMPOUND, C. WATER METER ETC. IF SHOWN ON PLAN, PAINT 44" WIDE EXIT PATH WITH PAINT P4 ON SLAB PRIOR D. WATER/WASTE/VENT TO APPLYING WAX. 2. WATER CLOSET ;T1 •PROVIDE VINYL WALL BASE PER 09/6A AND FLOOR TRANSITIONS REDUCERS PER 3. LAVATORY DRAWINGS AT AREAS WITH VCT 4. MOP SINK 5. WATER BOTTLE STATION G GI WASH/CLEAN/PREPARE FOR PAINT FINISH, 1 6. WATER HEATER G G GYPSUM BOARD SEE 09/1, PREPARE FOR PAINT FINISH. 7. WATER NEATER SHELF NG G G SG RADAR SERI S 2120 X2 X5/8- -CL "- EG LAR DG -WHIT ILES & B. HVAC - GRID, P OVI E IR G A D TILE & G ID T RATED CO DI 10 S PER PLANS. PROVIDE 9. TEMPERATURE CONTROLS ALL MATERIALS ACCESSORIES REQUIRED FOR COMPLETE INSTALL. E S F 11. AIR CURTAIN G G AT AREAS W EXPOSED CONCRETE OR VCT. PROVIDE MATCHING TRANSITION REDUCER. 16 ELEC ICAL GIGGIGI ONE COAT PRIMER, ONE COAT FINISH. PROVIDE LABOR AND MATERIALS FOR COMPLETE 1. STUB -IN FINISH APPLICATION PER MANUFACTURERS INSTRUCTIONS. PREPARE CLEAN AND 2. METERING VERIFY SUITABILITY OF SURFACES TO RECEIVE PAINT. STARTING CONSTITUTES 3. WIRING, CIRCUITING, SWITCHES ACCEPTANCE OF SUBSTRATE TO ACCEPT PAINT, GC TO CORRECT ANY 4. PANELS UNSATISFACTORY CONDITION W/O COST TO TENANT. PROVIDE MEASURES TO PROTECT 5. TRANSFORMERS ADJACENT MATERIALS, FINISHES, AND FIXTURES. REMOVE SPLATTERING AND LEAVE 6. DISTRIBUTION IN TENANT SPACE AREA IN CLEAN FINISHED CONDITION. SEE FINISH SCHEDULE FOR ALL PAINT COLORS 7. FLOOR BOX & RECEPTACLES SHEENS AND MFR. APPLY PER MFR RECOMMENDATIONS IF MORE STRINGENT. SPRAY 8. LIGHT FIXTURES APPLIED PAINT TO BE DRY FALL. A. INTERIOR - GENERAL & TRAC T GI IMAGINE EXPRESS BASS AD COLLAGE. GC TO PREPARE CLEAN AND VERIFY SURFACES B. EXTERIOR TO RECEIVE WALLCOVERING. GC TO CORRECT ANY UNSATISFACTORY CONDITION AT NO C. SIGNAGE COST TO TENANT. STARTING WORK CONSTITUTES ACCEPTANCE OF SUBSTRATE D. EMERGENCY LIGHTS & SIGNAG PREPARATION SUITABLE TO ACCEPT WALL -COVERING INSTALLER TO PROVIDE 9. TELEPHONE MEASURES TO PROTECT ADJACENT MATERIALS, FINISHES, & FIXTURES, CLEAN ALL 10. BUZZER SURFACES OF EXCESSIVE ADHESIVE, REMOVE SPLATTERING AND LEAVE AREA IN A m PATRICK i w � �.1 ME G. BLEES r n Q architecture - planning . Interior design z F- i s DESCRIPTION PATRICK G. BLESS, ARCHITECT SOD WASHINGTON AVE. N„ SUITE 208 MINNEAPOLIS, MN 55401-1148 _PHONE: (612) 547-1300 i INTERNALLY ILLUMINATED FACE -LIT SURFACE MOUNTED "G.H. BASS & CO." CHANNEL FAX: (612) 547-1301 LETTER SIGN. SEE ELEC SHEETS, GC TO COMPLETE FINAL CONNECTION. REFER TO SIGN E-MAIL: info®cmarch.com SHOP DRAWINGS. CONTACT- ANTHONY JOHNSON N/A ajohnson®cmarch.com G AS REQ BY AHJ. 3 G P LA LOR CIT IA CONSULTANTS: T ONE EXG, ONE NEW, PER LANDLORD CRITERIA. G 2A, 10 M U AT D, A DWI I 5 FT OF TRAVEL DISTANCE FROM ALL MECH/PLBG/ELEC AREAS. COORDINATE QUANTITIES AND LOCATIONS WITH AHJ, MOUNT AT 3'-0" AFF, EMANUELSON PODAS, INC PROVIDE BLOCKING IN WALLS FOR MOUNTING BRACKET. 10401 BREN RD EAST MINNETONKA, MN 55343 G G ONE (1) 18", ONE 36", & ONE (1) 42" LONG AT EACH TOILET ROOM, (952) 930-0050 PROVIDE BLOCKING IN WALL AS REQUIRED FOR APPLIED LOAD OF 2501bS. G G ONE (1) AT TOILET ROOM, PROVIDE BLOCKING IN WALL AS REQUIRED. G G ONE (1) AT TOILET ROOM, PROVIDE BLOCKING IN WALL AS REQUIRED. G G ONE (1) AT TOILET ROOM, PROVIDE BLOCKING IN WALL AS REQUIRED. G G ONE (1) AT TOILET ROOM, PROVIDE BLOCKING IN WALL AS REQUIRED. GGITT36" HIGH STANDARDS, BOT ® 60" AFF W/ (3) 1' x 3' MELAMINE SHELVES EQ SPACED. T "BOBRICK" B-224 N/A T SEE ELECTRICAL SHEETS. T SEE ELECTRICAL SHEETS. T SEE ELECTRICAL SHEETS. IT SEE ELECTRICAL SHEETS, GC TO COORDINATE LOCATION WZ CWN. SEAL: T G GC TO RECEIVE/OFF-LOAD AND INSTALL, SEE Al FOR LOCATION. - T G GC TO RECEIVE OFF-LOAD AND INSTALL, SEE Al FOR LOCATION. ��ct�aE C T G GC TO RECEIVE/OFF-LOAD AND SET IN PLACE, COORDINATE WITH CWN. 1�,?Z,CKG,!9/ \ f T G GC TO RECEIVE/OFF-LOAD AND INSTALL, COORDINATE WITH CWN. A N/A GC TO REMOVE, CLEAN AND REINSTALL, COORDINATE WITH A4 ELEVATIONS FOR RELO T G MOVEABLE STORAGE SYSTEM.„ , T 0 SEE ARCHITECTURAL PLANS, ELECTRICAL ELEVATION. T G SEE ARCHITECTURAL PLANS, ELECTRICAL ELEVATION. G G 3/4" C -LINE STANDARD WITH 2" X 2" WD BLOCKING TO 10'-6" AFF AND 48"W X 12"D WD SHELVES. SEE 10 A5 G G 36" X 48" CORK BOARD IN WOOD FRAME, MOUNT BOTTOM AT 4'-0" AFF, COORDINATE PERSON I L AO TER THE ITEM IN ANY LOCATION WITH STORE MANAGER, WAY UNLESS ACTING UNDER THE T G GC TO RECEIVE/OFF-LOAD AND INSTALL, SEE A3 FOR LOCATION. FIXTURE B-2 DIRECTION OF A LICENSED ARCHITECT. T G GC TO RECEIVE OFF-LOAD AND INSTALL PER MFR REQ, SEE A3 FOR LOCATION. PATRIC G. BLEE RC ITE T FIXTUREFIXED UNIT OF D 2A WITH HANG RODS. T T GC TO RECEIVE OFF-LOAD AND INSTALL, SEE A3 FOR LOCATION. SIGNATURE G_ G EXISTING MAIN & BRANCHES TO REMAIN. RELOCATE AND/OR PROVIDE ADDITIONAL 10/9/15 SPRINKLER HEADS AS REQUIRED PER STORE DESIGN/ GOVERNING CODES. SUBMIT DATE ISSUED SPRINKLER SHOP DRAWINGS TO LANDLORD & ALL APPLICABLE CODE OFFICIALS AS 031848-1 REQUIRED. PAINT EXPOSED FRONT OF HOUSE LINES P2. DO NOT PAINT HEADS. AS REG. NO. REQ BY AHJ PAINT REQ SYSTEM PARTS RED OR AS REQ BY AHJ. GIG, AS REQUIRED. SEE MECHANICAL AND ELECTRICAL SHEETS. GIGGIGI COORDINATE WITH LANDLORD, SEE MECHANICAL AND ELECTRICAL SHEETS. N A L L PER LEASE AND LANDLORD CRITERIA, COORDINATE WITH LL MANAGEMENT. G.H.Bass G G SEE MECHANICAL AND PLUMBING SHEETS. d► ej�e G G PER LEASE AND LANDLORD CRITERIA, COORDINATE WITH LL MANAGEMENT. f��/' G G SEE PLUMBING SHEETS. G G SEE PLUMBING SHEETS, MUST COMPLY WITH ADA REQUIREMENTS. G G SEE PLUMBING SHEETS, MUST COMPLY WITH ADA REQUIREMENTS, OUTLETS AT G G SEE PLUMBING SHEETS. PROVIDE MOP FAUCET HOSE. p G G SEE PLUMBING SHEETS, MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS. LAKE GEORGE G G SEE PLUMBING SHEETS. T G "HOLD -RITE" #40-2WHP-WM ABOVE MOP SINK - SUPPLIER: TWIN CITY HARDWARE 1424 STATE RT 9 G G SEE MECHANICAL SHEETS. n GIGI SEE MECHANICAL SHEETS, RELOCATE AS REQUIRED. GIGGIGI SEE ELECTRICAL SHEETS. G G SEE ELECTRICAL SHEETS. GIGGIGI SEE ELECTRICAL SHEETS. G G SEE ELECTRICAL SHEETS. N/A G G SEE ELECTRICAL SHEETS. G G SEE ELECTRICAL SHEETS. T G SEE ELECTRICAL SHEETS. EXISTING EXTERIOR EGRESS LIGHTING BY LANDLORD PER CODE. T G GC TO COMPLETE FINAL CONNECTION. T G SEE ELECTRICAL SHEETS. Rk CONTACT LOCAL TELEPHONE COMPANY. SEE ELECTRICAL SHEETS. G G SEE ELECTRICAL SHEETS. DOOR BUTTONS LOCATED WITHIN CASHWRAP AND OUTSIDE OF REAR DOOR ® 5'-0" AFF. SINGLE CHIME FROM CASHWRAP TO RING IN STOCK ROOM. DOUBLE CHIME FROM REAR DOOR TO RING IN STOCKROOM AND SALES AREA ANNUNCIATORS TO BE MOUNTED ABOVE CASHWRAP AND TO STOCKROOM CEILING. KEY • - EXISTING 0 - OTHER/TENANT'S VENDOR G - TENANT'S GENERAL CONTRACTOR T - TENANT L - LANDLORD/MALL N/A - NOT APPLICABLE LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: RESPONSIBILITY SCHEDULE/SPECIFICATIONS REVISIONS: NO: DATE: BY: PROJECT NO: 15101.020 DRAWN BY: OMC J, G2 COPYRIGHT PATRICK G. BLESS, AIA 2015 o_ Ln (3 in N L0 0 3 0 E 0 s 0 N O 0 40 i m a) 0 0 IL` c `o 3 m rn 3 0 0 r z ai rn 0 q) CD 0 0 J O N 0 = o / 0 U 0 m i m I 90'-3 1/2" LEASE DIMENSION I I I I _ L ---J L---�_---J _---J-- ----'� �-----I (( — — 2 / 9 / 6 / `— 9 I I I I I `y/ \\ --------1---------------J------- \ / -----+-----I-----------I-------I ----1----_J----- 6 ----� -----J 4 r- ---- ------ ------ 7 I -----------I-----I-----+----- I I ----L---------L----� ----J j 4 s 8 2 I i I -----------I-----------------i ----1----J-----I-----J 10--- - - - - - - - - - - - - - - / ----I-----I---------T-----I L- ----- ------ ------J----1--- --- ------ ----- 4 I g ` 9 2 2��\ ` 9 C2 12 I 2 111 q I--I----I --I —� F---T---T--- I T---� I--- I--- I— — I--�� �\ / �J I I I J NOTE: ANY AND/OR ALL EXISTING FIRE AND SMOKE DETECTION, PROTECTION, NOTIFICATION, EVACUATION, AND SUPPRESSION SYSTEMS, ETC ARE TO REMAIN (UNLESS OTHERWISE NOTED). GENERAL CONTRACTOR TO FIELD—VERIFY EXISTING CONDITIONS PRIOR TO STARTING DEMOLITION, AND REPORT ALL FINDINGS TO TENANT'S PROJECT MANAGER. MODIFY EXISTING SYSTEMS PER NEW STORE DESIGN AND COMPLIANCE WITH ALL APPLICABLE CODES. DEMOLITION KEY NOTES 19EXISTING WALLS TO REMAIN, SEE WALL -TYPES ON Al SHEET. 2 EXISTING STRUCTURAL COLUMNS TO AIN THROU OUT. 3 EXISTING ELECTRICAL EQUIPMENT TO REMAIN, SEE ELECTRICAL SHEETS. 4 REMOVE FLOOR FINISHES, SUB -FLOORING ADHESIVE, AND FLOORING THRESHOLDS THROUGHOUT SPACE (UON). GRIND, PATCH AND REPAIR SLAB TO ENSURE A SMOOTH, LEVEL r., FLOOR CONDITION VOID OF HOLES, CRACKS AND BUMPS WHERE NECESSARY FOR NEW FINISHES. 5 ,CORE DRILL jEXISTING CONCRETE SLAB IN AREAS OF NEW UNDER 'SLAB MECHANICAL, PLUMBING AND/OR ELECTRICAL. SAW -CUT TRENCHES IN SLAB AS NARROW AS POSSIBLE FOR INSTALLATION. PATCH/INFILL AS REQUIRED TO MATCH EXISTING CONDITIONS AFTER INSTALLATION OF NEW SYSTEMS. VERIFY WITH OWNER FOR APPROVAL BEFORE PROCEEDING WITH THIS WORK. SEE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS. �6 REMOVE DISPLAYS, STORAGE UNITS, CABINETS, COUNTERS, RAISED PLATFORMS, EQUIPMENT, ETC. THROUGHOUT THE SPACE AND ALL RELATED PLUMBING AND ELECTRICAL TO NEAREST AVAILABLE JUNCTION BOX OR SOURCE. RELOCATE THERMOSTATS PER TENANT DIRECTION. VERIFY WORKING CONDITION IN THE FIELD. SEE MECH SHEETS. �8 REMOVE WALL FINISHES: SLAT -WALL, PANELING, FURRING, FINISHES, WALL STANDARDS, TRIM, MIRRORS, ETC. AT ALL WALLS DOWN TO THE GYPSUM BOARD THROUGHOUT SALES AREA. COORDINATE REUSE OF WALL STANDARDS WITH TENANT'S PROJECT MANAGER AND FLOOR PLAN. �9 REMOVE PARTITION WALLS, INCLUDING BOLTS, ANCHORS, ETC. AT THE FLOOR LEVEL. REMOVE/CAP ELECTRICAL AND PLUMBING WITHIN WALLS BACK TO THE SOURCE. 10 REMOVE DOOR, CLOSER, FRAME, DOOR STOPS AND ALL ASSOCIATED HARDWARE. 11 EXG DOOR TO REMAIN. 12 EXG FITTING ROOM TO BE REMOVED IN ITS ENTIRETY. 13 EXG RESTROOM TO REMAIN 14 EXG TOILET TO BE REMOVED, PREP LOCATION FOR NEW FIXTURE. 15 STRUCTURAL SHEAR BRACING TO REMAIN. 16 REMOVE EXG PHONE BOARD AND EQUIPMENT. SEE ELECTRICAL SHEETS. GENERAL DEMOLITION NOTES 1. CONTRACTOR TO COORDINATE AND PERFORM ALL DEMOLITION & PROPERLY DISPOSE OF RUBBISH/ MATERIALS/EQUIP REMOVED/DEMOLISHED FROM THE JOB -SITE IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION AND LANDLORD CRITERIA. 2. GC IS RESPONSIBLE FOR MAINTAINING STRUCTURAL INTEGRITY OF LANDLORDS STRUCTURE AND PROTECT ELEMENTS AND PERSONNEL FROM DAMAGE AND HARM. CEASE OPERATIONS AND NOTIFY OWNER IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUME OPERATIONS UNTIL SAFETY IS RESTORED. 3. ANY ITEMS, FIXTURES, EQUIPMENT, SYSTEMS, OR DEVICES INDICATED TO REMAIN OR BE REUSED, ARE TO BE INSPECTED BY QUALIFIED TECHNICIAN OR TRADESPERSON PRIOR TO REUSE. CLEAN/REPAIR REUSED ITEMS TO "LIKE -NEW" CONDITION, REPLACE AS NECESSARY. 4. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMMODATE NEW WORK AS INDICATED IN THESE DRAWINGS, INCLUDING THAT REQUIRED FOR CONNECTION TO THE EXISTING BUILDING. DEMOLITION NOTES MAY NOT NECESSARILY SPECIFY ALL DEMOLITION THAT IS REQUIRED. PHASE DEMOLITION IN ACCORDANCE WITH CONSTRUCTION SCHEDULE. 5. DEMOLISH WITHOUT EXCESSIVE NOISE, DUST, OR FUMES, SO AS NOT TO DISRUPT BUSINESS OF ADJACENT TENANTS OR MALL OPERATIONS. 6. PLACE MARKERS TO INDICATE LOCATION OF DISCONNECT SERVICES. IDENTIFY SERVICE LINES AND CAPPING LOCATIONS ON PROJECT RECORD DOCUMENTS. 7. ARRANGE AND PAY FOR DISCONNECTION, REMOVING & CAPPING OF UTILITY SERVICES WITHIN AREAS OF DEMOLITION. DISCONNECT AND STUB OFF ALL UTILITIES AFFECTED BY THE DEMOLITION WORK. NOTIFY THE AFFECTED UTILITY COMPANY AND LANDLORD REPRESENTATIVE IN ADVANCE & OBTAIN APPROVAL PRIOR TO THIS WORK. CAP SERVICES AT POINT OF ORIGIN IF POSSIBLE. 8. REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED FOR THE WORK DESCRIBED HEREIN, AT NO COST TO TENANT. 9. REMOVE ALL EXISTING OR NEWLY ABANDONED MATERIALS, ELECTRICAL, MECHANICAL, AND PLUMBING EQUIPMENT ITEMS, PIPING, DUCTS, CONDUIT AND WIRING, ETC., BACK TO THE SOURCE, INCLUDING ROOF TOP EQUIPMENT, CURBS, ETC. PATCH ROOF PER LANDLORD'S REQUIREMENTS. 10. WHERE COMMUNICATION, COMPUTER, SECURITY, OR TELEPHONE LINES ARE (RE)LOCATED, COORDINATE WITH THE TENANT FOR ROUTING & TIMING OF NEW LINES TO SERVICE REGISTERS & SECURITY/SOUND. ABANDONED COMMUNICATION LINES ARE TO BE IDENTIFIED, MARKED, AND CAPPED/REMOVED AS INDICATED/REQUIRED TO NEAREST AVAILABLE JUNCTION BOX OR SOURCE. 11. HVAC CONTRACTOR TO INSPECT EXISTING CONDITIONS PRIOR TO DEMOLITION AND DETERMINE THE EXISTING SYSTEMS/COMPONENTS CONFORM TO DESIGN INTENT AND WHETHER ANY COMPRESSOR REFRIGERANT LINES ARE PRESENT THAT MUST BE PROPERLY DRAINED (TO EPA STANDARDS). 12. CONSTRUCT STOREFRONT BARRICADE WITH ONE LAYER OF 5/8" FIRE -RATED TYPE 'X' GYPSUM BOARD ON METAL STUDS, TAPED AND PAINTED AS DIRECTED BY THE LANDLORD'S FIELD REPRESENTATIVE. PATRICK G. BLEES architecture • planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info0cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK LEEE5 ARC ITECT % �� SIGNATURE 10/9/15 DATE ISSUED 031848-1 on G.H.bass el ftCoo OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: DEMOLITION PLAN REVISIONS: NO: DATE: BY: 11/24/15 LL/BASS 0 12/3/15 LL/BASS PROJECT NO: 15101.020 DRAWN BY: OMC 1 COPYRIGHT PATRICK G. BLEES, AIA 2015 PATRICK G. BLEES architecture • planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK - ELLE �i ;CH,1TECT /-SIGNATURE 10/9/15 DATE ISSUED 031848-1 REG. NO. G.H.Bass V CO. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: DEMOLITION REFLECTED CEILING PLAN REVISIONS: NO: DATE: BY: PROJECT NO: 15101.020 DRAWN BY: OMC D1.1 COPYRIGHT PATRICK G. BLEES, AIA 2016 NOTE: ALL FLOOR PLAN GENERAL NOTES, FLOOR PLAN KEY NOTES, FINISH PLAP GENERAL NOTES, PARTITION GENERAL NOTES AND WALL TYPES LOCATED f1 ON SHEET A1.1. Y NU I tti T CASHWRAP PROVIDE DROP THROUGH ELECTRICAL CONDUCTORS -SEE W TELEPHONE — SEE ELECTRICAL R CAT -5 CABLES WITH PULL STRING. OWER AND DATA J—BOXES WITHIN L 2/A-5.0 BOARD, BOTTOM ® 4'-0" AFF, SEE REMAIN. PROVIDE NEW FIXTURES, NISHES AS INDICATED ON ARCHITECTURAL A4.1. AND PREPARE FOR NEW FINISH P1 AND PREPARE FOR NEW FINISH = %IN. CLEAN AS REQUIRED. NEW PARTITION TO FINISH FACE OF EXC A SMOOTH FINISH CONDITION. N, FRAMING, AND GYP BD, TO DECK. TALL OPENING INDICATED LOCATION. REPAIR GYP BD AN PATRICK G. BLEES architecture • planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK G. BLEES,; ARCUITECT 10/9/15 DATE ISSU 031848-1 REG. NO. ev ftCo. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: FLOOR PLAN REVISIONS: NO: DATE: BY: PROJECT NO: DRAWN BY: Al TH 15101.020 OMC COPYRIGHT PATRICK G. BLEES, AIA 2015 m PATRICK EN G. BLEES architecture• planning - interior design .. PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: SOK G. �; 31848-1 ,n�I IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PA��i��I-TECT� uxt. 10/9/15 DATE ISSUED 031848-1 REG. NO. G.,H,.Bass co' OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: DETAILS AND SCHEDULES REVISIONS: NO: DATE: BY: PROJECT N0: 15101.020 DRAWN BY: OMC Al A COPYRIGHT PATRICK G. BLEES, AIA 2015 Y %y 1U -U „rr ACT1 09 5 _ —a 1_ NEW 2X2 AC CSP 10'-0 AFF)R ACT1 09 I 5C d- 0 1 NEW 2X2 ACT ® 10'-0' AFF ACT109 5C / m 2'43" 12' 5' ( NOTE: G.C. TO VERIFY LOCATION OF EXG DUCTWORK AND MINIMALLY ADJUST LIGHTING TO AVOID CONFLICTS. COORDINATE WITH CONSTRUCTION PROJECT MANAGER BEFORE MAKING ANY CHANGES. ACT' 59 (EXG) P1 OPEN TO DECK 014'-7" AFF P1 16'-0" 16 (EXG) NL 8D NOTE: VERIFY EXISTING DUCTWORK SIZE AND LOCATION IN FIELD. DUCTWORK TO BE 13'-6" AFF (MINIMUM) OR HIGHER AND SHALL NOT INTERFERE WITH NEW CONSTRUCTION OR LIGHTS. NOTIFY OWN PROJECT MANAGER. W-11 3/4" N C7 REFLECTED CEILING PLAN SCALE 1/4" = 1'-0" d w 6'-11 3/4" NOTE:_ CEILING OPEN TO DECK ABOVE. PAINT ENTIRE DECK/STRUCTURE, CONDUITS, METAL RODS, CHAINS AND SALES WALLS P1 ,UON. ®14.-7" 'i P1 1 8. Bn ® 2. BN1 M ..., m 2'-0" c� F r F N 5'-0" E i 2 1 3 4 A LIGHT FIXTURE O1 PROVIDE 4 -AIRCRAFT CABLE HANGERS FOR 25LB. LIGHT FIXTURE. FIXTURE SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. OCABLE AT (4) CORNERS. O2 X 2 FLUORESCENT LIGHT FIXTURE. OCABLES SHALL BE ATTACHED TO THE CEILING SYSTEM WITH POSITIVE CLAMP DEVICES (NOT SHOWN). - RCP SYMBOLS ;LEGEND QTY SYMBOL DESCRIPTION LAMP TYPE QTY SYMBOL DESCRIPTION LAMP TYPE LA LIGHTING; 28 -LCD 847-2-2RU6-W9-2E81-UNV 2'X2' 9 CELL PARABOLICW FLUORESCENT, STEEL CABLE HUNG, WHITE ALUMINUM LOUVER, GE T8 U BEND - 4 PHILLIP'S FORECAST: F9079519NV SCONCE FIXTURE - OCEAN VIE= BLACK 60 WATT INCANDESCENT 38 ® � (1) 2 LAMP ELECTRONIC BALLAST. (2) F32T8/SP30/U/6 SUSPEND AT W-10" AFF TO BASE OF FIXTURE. GC TO SUPPLY CABLE. ADJUST LOCATION DUE TO SITE CONDITIONS/OBSTRUCTIONS. 1 EXG EXHAUST FAN 8 DUAL LAMP STRIP, FLUORESCENT -SUSPEND W/ CHAINS AT 13'-6"f AFF, VIF T8 LAMP (2) F028/830/XP/SS/ECO 2 DUAL LAMP STRIP FLUORESCENT -SUSPEND W/ CHAINS AT 13'-6"f AFF, VIF 4' LIGHTOLIER LYTESPAN TRACK (WHITE) WITH MOUNTS @ 4'-0" O.C. LENGTHS TO NEAREST PHILIPS: CHLORIDE VCRWLRC - LED EXIT SIGN AND 5.4W TUNGSTEN HALOGEN - FOOT AS REQUIRED. -SURFACE MOUNT TO UNDERSIDE OF SOFFIT/FACE OF BULKHEADAT EMERGENCY LIGHT COMBINED UNIT, WITH BATTERY BACK-UP, MOUNT ABOVE STOREFRONT. PAINT ROD AND UNISTRUT P1 2 12'-6" AFF IN STOCKROOM AND 11'-4" AFF OTHERWISE OR PER AHJ, SEE ELEC SHEETS - 4' "HALO" WHITE TRACK (NON WIRED) AT LENGTHS INDICATED WITH (4) HALO L961 P PHILIPS: CHLORIDE VERWEM -EXIT SIGN WITH BATTERY BACK-UP, MOUNT HOOKS ON EACH LENGTH OF TRACK SUSPENDED @ 10'-6" AFF FROM STRUCTURE 1 ® ABOVE 12'-6" AFF IN STOCKROOM AND 11'-4" AFF OTHERWISE OR PER AHJ, ABOVE WITH CHAINS, HOOKS FURNISHED BY TENANT SEE ELEC SHEETS SPEAKERS FURNISHED BY TENANT, INSTALLED BY GC. SUSPEND @ 1AFF LIGHTOLIER: 81 F70T6WH GE CMH 70W 33 LYTESPAN TRACK FIXTURE- METAL HALIDE WALL WASH - T6 -70W CERAMIC METAL CMH70TU/830/G12 8 S O FROM DECK/STRUCTURE ABOVE W/ UNISTRUT &THREADED ROD, SPECEC 16/11. BM -W HALIDE 1 EXG INCANDESCENT TROUGH LIGHT 146 LIGHTOLIER: 9022WH LYTESPAN TRACK FIXTURE - 17W LED PAR 38 WITH 40° FLOOD 14 LIGHTOLIER: 1102P1 - 1961 - 1113 T9 RECESSED CEILING FIXTURE - 6 3/4" APERTURE PAR38 RECESSED DOWNLIGHT CLEAR 3 �I EXG EXIT SIGN REFLECTOR, WHITE TRIM RING, HANGER BARS INCLUDED, 17 W LED PAR 38 40' FLOOD LED17E26P3830KFL 3 HI -LITE MFG. CO. : H-15116-93' / 30" ST-HSC-93/GL-PAN-FR WAREHOUSE COLLECTION SHADE. WHITE, 30" WHITE STEM MEDIUM BASE SOCKET. EL/MDT2 13W 5 CEILING MOUNT EMERGENCY LIGHT W/ SELF CONTAINED POWER PACK FOR 90 MIN OPERATION. WHITE HOUSING. INSTALL AS CLOSE TO CEILING AS ALLOWED 15 WATT MOUNTED 85" A.F.F. TO BOTTOM OF FIXTURE. GC TO USE (1) 12" LENGTH & (1) 18" (41399-6) PER CODE. HALOGEN LENGTH STEM TO INSTALL PENDANT NOTE: 1. "N/L" INDICATES NIGHT LIGHT FIXTURES. 2. LIGHT FIXTURES AND LAMPS FURNISHED BY TENANT UNLESS OTHERWISE NOTED. 3. GC TO PROVIDE REQUIRED MATERIALS FOR COMPLETE INSTALLATION OF LIGHTING (UNISTRUT THREADED RODS, AIRCRAFT CABLE, ET(;) UNLESS OTHERWISE NOTED, 4. "R" INDICATES EXISTING LIGHT FIXTURES TO BE RELOCATED. ORIGID VERTICAL STRUT. O12" GAUGE WIRE SPLAYED ON FOUR DIRECTIONS 90' APART AT 12'-0" O.C. EACH WAY. OACOUSTICAL CEILING PANELS. (TYPICAL) 1 TYPICAL CEILING DETAIL 3 NOT USED A2.1 SCALE' 1/2 Is 1'-o" A2.1 THREADED ROD TO STRUCTURE ABOVE BY GC. METAL ROD HANGER UNISTRUT ATTACHED 0 0 o TO STRUCTURE ABOVE 0 0 0 48" O.C. ° ° °`�� "UNISTRUT" #P1047 (6 THUS) CONTINUOUS METAL "UNISTRUT #P2862 (4 THUS) CONTINUOUS - �J ANGLE SECURED TO -- STUDS BEYOND METAL ANGLE UNISTRUT11 FI I, SECURED WATER HEATER TO METAL STUDS FRT W000 3/8 THREADED ROD 2" x 2" CONTINUOUS BLOCKING THREADED ROD BRACKET SUPPLIED WITH SHELF METAL ANGLE 5/8" GYP BD ON 0 o o ASSEMBLY (4 THUS) SECURED MTL STUDS PAINT P2 o TO BLOCKING & 0 0 ,. METAL STUDS �, UNISTRUT' #P1000 / P1100 (2 THUS) B.O. SOFFIT "TOGGLER" TOGGLE BOLT #3/8-16 AT METAL SEE SHEET A-3.0 36" OR EXTEND PAST 3 STUDS (MIN) STUD WALL CONDITION (12 THUS) 3 5/8" METAL STUD 3 SEE REFLECTED CEILING PLAN A-3.0 FRAMING @ 16" O.C. ELEVATION 5/8" GYP BD ON MTL RECESSED a A STUDS PAINT P2 DOWN LIGHT � NOTE: N SHELF ASSEMBLY IS K74CEILING SOFFIT 0 OPEN CEILING CONDITION ENGINEERED TO SUPPORT o WATER HEATERS UP TO A2.1 SCALE 1" = 1$-0" 0 20 GAL OR 375 LBS EXISTING Ln CONSTRUCTION m"UNISTRUT #P1000 / P1100 (2 THUS) o "UNISTRUT" #P2862 (4 THUS) CL FRT c �,; WOOD - THREADED ROD BRACKET SUPPLIED WITH SHELF BLOCKING 3 L3 ASSEMBLY (4 THUS) METAL ROD HANGER N WATER HEATER CONTINUOUS ®48' O.C. ° METAL ANGLE 3 SECURED 0 3/8" THREADED ROD TO METAL STUDS 0 r ; ; ','UNISTRUT" #P2380-4 (10 THUS) z a EQUIPMENT SHELF ASSEMBLY _ 2" x 2" CONTINUOUS METAL ANGLE SECURED ° TO BLOCKING & METAL CD "UNISTRUT" #P1047 (6 THUS) STUDS `L ,111 y"TOGGLER"TOGGLE BOLT #3/8-16 AT METAL RECESSED 3'5/8" METAL STUD # / DOWN LIGHT 8' NO FRAMING @ 16" O.C. o STUD WALLCONDITION(12 THUS) (ADJUST MINIMALLY TO B SECTION ACCOMMODATE LIGHTING) N o: LO 0 5/8" GYP 8D, j PAINT P2 0 U 2 WATER HEATER SHELF DETAIL 5 CASHVVRAP CEILING SOFFIT 2.1 SCALE 1" _ 1'-o" A2.1 SCALE 3/8" = 1"-0" d 11 0i t. PATRICK l G. BLEES architecture • planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 ' FAX: (612) 547-1301 E—MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson@cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 93D-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRIC G. LEES A CH TECT SIGNATURE 10/9/15 DATE ISSUED 031848-1 REG. NO. j Go s ass a CC V C ®s OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: REFLECTED CEILING PLAN DETAILS REVISIONS: FIRE PROTECTION GENERAL NOTES NO: DATE: BY: 1. LANDLORD TO PROVIDE A COMPLETE FIRE SPRINKLER SYSTEM THROUGHOUT THE DEMISED SPACE IN ACCORDANCE NFPA STANDARDS AND APPLICABLE CODES. MODIFICATIONS TO SPRINKLER SYSTEM DUE TO TENANT'S STORE DESIGN SHALL BE PERFORMED BY LANDLORDS APPROVED, STATE CERTIFIED FIRE SPRINKLER DESIGNER/CONTRACTOR AT TENANT'S EXPENSE. 2. FIRE SPRINKLER DESIGNER/CONTRACTOR TO COORDINATE WORK AND SUBMIT NECESSARY DOCUMENTATION TO LANDLORD AND AUTHORITIES HAVING JURISDICTION PRIOR TO INSTALL. 3. PROVIDE UP -TURNED HEADS AND EXTENSIONS AS NECESSARY AT OPEN -TO -STRUCTURE CONDITIONS. DO NOT PAINT HEADS, FLOW NOTES, ETC. ' 4. PROVIDE CONCEALED/FULLY-RECESSED HEADS WITH BLOW OFF CAPS AT HARD SURFACE CEILING AREAS. DO NOT PAINT HEADS, FLOW NOTES, ETC. 5. PROVIDE SEMI -RECESSED HEADS AT ACT CEILING LOCATIONS. ' DO NOT PAINT HEADS. 6. LANDLORD TO PROVIDE A COMPLETE FIRE ALARM SYSTEM AS REQUIRED PER APPLICABLE PROJECT N0: 15101.020 CODES AND NFPA STANDARDS. MODIFICATIONS TO ALARM SYSTEM DUE TO TENANT'S STORE DRAWN BY: OMC DESIGN SHALL BE PERFORMED BY LANDLORD APPROVED, STATE CERTIFIED FIRE ALARM DESIGNER/CONTRACTOR AT TENANT'S EXPENSE. 7. FIRE ALARM DESIGNER/CONTRACTOR TO COORDINATE WORK AND SUBMIT NECESSARY A2* DOCUMENTATION TO LANDLORD & AUTHORITIES HAVING JURISDICTION PRIOR TO INSTALLATION: COPYRIGHT PATRICK G. BLEES, AIA 2015 PATRICK zliffl G. BLEES architecture -', planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson@cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: CK G. '3� IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. !PATRICK � ,_ A CH TEC. IGGNNNA,TUU%RAE 10/9/15 DATE ISSUED 031848-1 REG. NO. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: FIXTURE AND EGRESS PLAN REVISIONS: NO: DATE: BY: PROJECT NO: DRAWN BY: 15101.020 OMC A3 COPYRIGHT PATRICK G. BLEES, AIA 2015 STORE FRONT EXG. QTYW FIXTURE NAME DESCRIPTION 0 1 F-12 F-12 TALL DISPLAY CUBE TALL SEE DETAILS SHEET A-4:1 0 TALL 0 2 F-12 F-12 SHORT DISPLAY CUBE TALL SEE DETAILS SHEET A-4,1 4 SHORT L; FITTING ROOMFIXTURES Qly EXG. EW FIXTURE NAME' DESCRIPTION 0, 1_ F-15 ADA F-15 ADA 17" x 24" x 48" ADA -FITTING ROOM BENCH 0 4 F 15H FITTING ROOM TOWEL BAR � F-1 5H O 4 L F 19 COLD ROLLED STEEL ANGLE CORNER GUARD 0 1 0 31 HANGER BIN ACC 0 1 Bp B2 HARDWARE BIN 0 4 M2 1'-1"x6'—O" MIRROR 0 4 ' M3 2' 0"x6'-0° MIRROR 0; I I 2❑L T TABLES (COUNT LOCKER EMPLOYEE LOCKERS FIXTURE LEGEND EXG. NEW FIXTURE NAME DESCRIPTION - SAL S F1 OOR 2 0 Fz- ACC SLA F2 -ACC SLAT HAT FIXTURES 3 F3—ACC TALL ACCESSORY 4 0 ACC BELT TOWERS/BELT TALL FIXTURE NT -TALL APPAREL NESTING 10 0 TABLES (COUNT NT—LOW SETS OF 2) 4 O ❑ F4—FT SHOE FEATURE' TABLES 4 0 FRO ROME LL R_ROROME CHROME ROLLING RACK 8 F4 F4 BALLET BARRE (INSTALLED BY TENANT) 83 0 F5 SHOE BIN Fs FIXTURES — TALL . Sc SUNGLASS TOWER 1 0 SG — DARK BROWN SUNGLASS TOWER 1 0 SG SG — LIGHT BROWN F6-70MBO F6 _ APPAREL COMBO 0 2 COMBO FIXTURES (SHELVED OR HANGING) F7—ACC F7 — WHITE 2 SIDED 4 0 ACC WH ACCESSORY FIXTURES WH Q 1�F•13L� F -13L 54" BACKWRAP — LEFT 0 1.13 F -13R 54" BACKWRAP —RIGHT 0 CASHWRAP 1 acro- F14CTR—R COUNTER-CENTER—RIGHT CASHWRAP 0 1 Fiacra F14CTR—L COUNTER-CENTER—LEFT 0 1 Ft40 CASHWRAP REGISTER F1 4C CABINET 0 22 AP AP SHELF — APPAREL BAY 0 17 Dff SHELF - SHOE BAY SH 0 3 LG LC SHELF - LUGGAGE BAY 6 AC SHELF — ACCESSORY AC BAY 0 2 CLR SHELF — CLEARANCE CLR BAY Q 7 ST ST STOOLS AT SALES FLOOR &,REG. FITTING ROOMS O 8 M4 FIXTURE ENDCAP MIRRORS 1 �r PATRICK G. BLEES architecture • planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON.AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson@cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: 1 Pa �,r�;T'18•^.8'� ,tib' IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK EES�A�HI ECT -SIGNATURE 10/9/15 DATE ISSUED 031848-1 REG. NO. G.H.Bass to, wl CO. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: FIXTURE SCHEDULES AND DETAILS REVISIONS: NO: DATE: BY: PROJECT NO: 15101.020 DRAWN BY: DMC A.1 COPYRIGHT PATRICK G. BLEES, AIA 2015" x m W 4 O N O O i 0 0 IL` c 3 rn 3 0 .o r z 6 m 0 Y J O N O O to 0 U fA O m- SCALE 114w := 1'-0" LEFT SCALE Ile = 1'-0" REAR B2 SIDES SCALE Ile = 1'-0" 7O mw1ia0 16 4'-11 3/4" 8D 5'-1 1 MT FITTING ROOM L OPEN TO FITTING ROOM FOYER 14" DES ALL P2 ALL P1 TYP SIDES B2 SIDES B2 ALL SIDES f TY" 24" TYP ALL SIDES NTP -f if* P1 pWT1 TYppP II II ALL SIDES 48'-9 1/2" GENERAL PAINT NOTE: CONTINUE Pt BEHIND ALL FIXTURES UON. I 08 3 a (EXG) _ I Y J 5m v oz o 10 m� (i 8C a AA 1 0 STOREFRONT SIGNAGE NOTE: SIGNAGE UNDER SEPARATE SUBMITTAL, PERMIT AND REVIEW. REFER TO SIGN MANUFACTURERS SHOP DRAWINGS WALL PANELS: NEW:65 STANDARDS EXISTING: 38 STANDARDS OWNER TO PROVIDE TOGGLES AND SCREWS FOR ALL RELOCATED AND NEW WALL STANDARDS. W z J 8B (EXG) SCALE 1/40 = 1'-0" 08 3 (EXG) f� — A (EXG) .L 8B (EXG) \ 6A a 8 0 08 0 (�) (E�\ 00 (EXG)-----�- (NEW) W d UjZ J J 0 (EXG) o JIM" PATRICK G. GLEES architecture - planning • interiordesign PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: tl I IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK BLEES, CHITECT '81GNAIURE 10/9/15 DATE ISSUED 031848-1 REG. NO. G.H.Bass tocr Coo OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: ELEVATIONS REVISIONS: NO: DATE: BY: PROJECT NO: 15101.020 DRAWN BY: OMC A4 COPYRIGHT PATRICK G. BLEES, AIA 2015 2 a M CV r Lo 6 Lo I N U Y NOTE: TOILET ROOM FINISHES EXISTING. VERIFY IN FIELD, PATCH/REPAIR AS REQUIRED, MATCH EXISTING. �� PLAN -TOILET SCALE 1/4" = 1'-0" (EXG) L ¢5 (EXG) -H oC) I¢ Co 2 TO LET 4• SCALE 1/4-w = 1'-0" (EXG) 4'-10" (EXG) 3 TOILET 4 TOI LET A4.1 SCALE 1/4" = 1'--o' A4.1 SCALE 1/4" = 1'-0" 5'-11 3/4" A FITTING ROOM SCALE 1/2" = 1'-0" i 1 F-15 ADA 08 se M -BENCH I ADA FITTING ROOM 106 1 09 WAX1 09 4 BB22 6 (2) 106 SCALE 1/2* = 1'-0" O T 0 r� 4'-10" (2) 0 KUUN 105 11" FITTING ROOM FOYER 104 a09 Wf WAX1O91 (2) 4'-0" L L C C 10'-9 1/4" 6;=3 3/4„ II III Ilf If / GC TO PROVIDE 1X BLOCKING AS REQ FOR ATTACHMENT OF FIXTURE, = FINISH. COVERING S.F. =231. U 0A 6B a 1 ,. io i N 10'-9 1/4" 6;=3 3/4„ II III Ilf If / GC TO PROVIDE 1X BLOCKING AS REQ FOR ATTACHMENT OF FIXTURE, = FINISH. $ STOREFRONT DISPLAY WALL A4,1 SCALE 1/4" = 1'-0" RIOR TO FITTING ROOM ONSTRUCTION, MANAGER 0 CONFIRM LOCATIONS F FITTING ROOM UCK/TOWEL BAR/PLAQU ENCH AND GRAB BAR OCATIONS. BLOCKING Tt E PROVIDED AS ECESSARY. !STALL J -BOXES FOR ISTALLATION OF WALL CONCES IN FITTING OOM. VERIFY J -BOX DCATION WITH FIXTURE OUNTING HEIGHT PER 1 FVATIhNS WALL COVERING S.F. =231. • • ,. ��® i ®®® S $ STOREFRONT DISPLAY WALL A4,1 SCALE 1/4" = 1'-0" RIOR TO FITTING ROOM ONSTRUCTION, MANAGER 0 CONFIRM LOCATIONS F FITTING ROOM UCK/TOWEL BAR/PLAQU ENCH AND GRAB BAR OCATIONS. BLOCKING Tt E PROVIDED AS ECESSARY. !STALL J -BOXES FOR ISTALLATION OF WALL CONCES IN FITTING OOM. VERIFY J -BOX DCATION WITH FIXTURE OUNTING HEIGHT PER 1 FVATIhNS WALL COVERING S.F. =231. 6'-6" 10'-9 1/4" SCALE 1/2* = 1'—o" PATRICK ,_ G. BLEES architecture - planning • interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info0cmarch.com CONTACT: ANTHONY JOHNSON ajohnson0emorch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: r IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK LEE , ARCHITECT SIGNATURE 10/9/15 DATE ISSUED 031848-1 REG. N0. G. H. 9 r Gy %N.W C OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: ELEVATIONS AND ENLARGED PLANS REVISIONS: NO: DATE: BY: 1/24/15 GHB PROJECT NO: 15101.020 DRAWN BY: OMC A4o1 COPYRIGHT PATRICK G. BLEES, AIA 2015 PATRICK G. BLESS architecture . planning > interior design 'ATRICK G. GLEES, ARCHITECT 100 WASHINGTON AVE. N., SUITE 208 AINNEAIHONEPOLIS, MN 55401-1148 (612) 547-1300 'AX: (612) 547-1301 --MAIL: info®cmarch.com ;ONTACT:ANTHONY JOHNSON ajohnson®cmarch.com "ONSULTANTS: NECH/PLBG/ELEC [MANUELSON PODAS, INC 0401 BREN RD EAST AINNETONKA, MN 55343 1952) 930-0050 IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRICK G. BLEES AR HITECT NATURE 10/9/15 DATE ISSUED 031848-1 REG. NO. M OUTLETS AT LAKE GEORGE GEORGE 12845 #7 #4197 ELEVATIONS COPYRIGHT PATRICK G. BLEES, AIA 2015 2}re" O PASSTHRU HOLES IN TOP OF CASHWRAP DEDICATED DUPLEX - DUPLEX OR QUAD SEE PLAN SENSORMATIC OUTLET CAT 5 JACKS 3 a 0 N Q 0 N 0 0 to U) m 0 0 a c 0 3 m rn .3 0 L } z m rn 0 c� v 0 J 0 N 0 0' LO 0 0 In 0 0 m i U 0 I N SM A DE—TAGGER, MOUNT 2" BACK FROM/t- FRONT OF PULL OUT TRAY 16 a_ F14TOP-8 CASHWRAP COUNTERTOP (2 PIECES) w LO n NOTES: cr A. 12/2B, 12/2C ARE COMPOSED OF e4 TYPICAL 12/2A COMPONENTS. B. FROM FLOOR; INSTALL 24" DEEP 0 - WORKSURFACE 0 34" AFF, INSTALL SHELF 0 6Q"AFF, INSTALL SHELF 20" LO °I CLEAR ABOVE FIRST SHELF AND SHELVES EVERY 17" ABOVE. C. STORAGE SYSTEM NOT ATTACHED TO I 00 WALLS, SECURE TO FLOOR PER MFR'S N I SPECIFICATIONS ,FL a Y 00 0 a 24" DEEP X 48" WIDE WORK I SURFACE 0z `V w 23" DEEP CLEAR FLOOR —0" Z _ SPACE TO REAR BRACKET NORK 0 SIDE BRACKET S RFAC 3'-10 1/2" z ¢ a REAR SHELF BRACKET ONLY 23" CLEAR NO FRONT BRACKET I CLE U 1 NOT USED00 NOT USED " 4 9 STOCKROOM DESKS A5 A5 AS SCALE 3/8" = 1'-0" 2}re" O PASSTHRU HOLES IN TOP OF CASHWRAP DEDICATED DUPLEX - DUPLEX OR QUAD SEE PLAN SENSORMATIC OUTLET CAT 5 JACKS 3 a 0 N Q 0 N 0 0 to U) m 0 0 a c 0 3 m rn .3 0 L } z m rn 0 c� v 0 J 0 N 0 0' LO 0 0 In 0 0 m i U 0 I N SM A F14CTR—L F1 4C ADJUSTABLE SHELVES: SHIFT AS NECESSARY TO FIT EQUIPMENT (TYP ALL UNITS) B REAR ELEVATION I F14TOP—B CASHWRAP COUNTERTOP (2 PIECES) (FRONT EUVATION V - CASHWRAP DETAILS SCALE 1/2w = 1'-0" . Zvi i R :4 1 is •. SCALE 1/2w = 1'-0" DE—TAGGER, MOUNT 2" BACK FROM FRONT OF PULL OUT TRAY F14CTR—R REMOVABLE PANEL (ADA) NO CONDUIT FROM SLAB BELOW THIS UNIT 2Xz"O PASSTHRU HOLES IN TOP OF CASHWRAP Will ;W*17003 Y ,t NOTE: FITTING ROOM FOYER SIGNAGE TO BE CENTERED OVER DOOR OPENING. SPACING BETWEEN LETTERS IS 1/4" TYP. N ROOM FITTING ROOM FOYER BEYOND SCALE 1' = 1 °-O" PARTITION, SEE PLAN T.O. STANDARI PARTITION, SEE PLAN i 10'-0" AFF WD SHELF M 3/4" C -LINE STANDARD € MTL BRACKET METAL SHELF BRACKET 3/4" C—LINE STANDARD ATTACHMENT (TYP BOTH SIDES) VA WD SHELF 4" VINYL BASE 4713/16' / STORAGE SHELVING GENERAL NOTES 1. GC TO ASSEMBLE AND INSTALL TENANT FURNISHED STORAGE SYSTEM (12/2A, 12/26, 12/2C, 12/2G) (UPRIGHTS, SHELVES, MISCELLANEOUS ACCESSORIES, ETC.) 2. EACH 10'-0" HIGH SHELVING UNIT EXCEPT MANAGER & EMPLOYEE DESK UNITS ARE TO BE ASSEMBLED WITH ONE (1) SHELF AT TOP AND ONE (1) SHELF AT BOTTOM UON. 3. SEE 9/A5 FOR 12/28, 12/2C. 4. STORAGE SYSTEM NOT ATTACHED TO WALLS, SECURE TO FLOOR PER MFR'S SPECIFICATIONS. 5. FIELD VERIFY VERTICAL AND HORIZONTAL CLEARANCES. 6. LEAVE EXTRA PARTS AT STORE FOR FUTURE USE. 10'--01' STORAGE SHELVING LEGEND n FROM BTM SHELF, INSTALL A SHELF EVERY 12th NOTCH, 11 NOTCHES BETWEEN (6 SHELVES) © FROM BTM SHELF, INSTALL (6) SHELVES EVERY 8th NOTCH, 7 NOTCHES BETWEEN. FROM TOP SHELF INSTALL (1) SHELF IN 11TH NOTCH, 10 NOTCHES BETWEEN (8 SHELVES) (accessories) ©FROM BTM SHELF, INSTALL (1) SHELF AT 7th NOTCH, 6 NOTCHES BETWEEN. THEN INSTALL (4) SHELVES AT EVERY 6th NOTCH, 5 NOTCHES BETWEEN. THEN INSTALL A SHELF EVERY 18th NOTCH, 17 NOTCHES BETWEEN WITH 4 HANGROD ASSEMBLIES. (7 SHELVES — 4 HANGRODS) (garments). PROVIDE 6 ADDITIONAL HANG RODS AND 12 ADDITIONAL BRACKETS IN THE MOST COMMON WIDTH. FROM BTM SHELF, INSTALL 2 SHELVES, ONE AT EVERY 17th NOTCH, 16 NOTCHES BETWEEN AND 2 HANGROD ASSEMBLIES BETWEEN EACH PAIR OF SHELVES. THEN INSTALL ONE SHELF AT EVERY 13th NOTCH, 12 NOTCHES BETWEEN (5 SHELVES — '4 HANG RODS) (hangers) MANAGER UNIT — NO SHELF AT BTM. FROM TOP SHELF, INSTALL (1) SHELF AT 8th NOTCH, 7 NOTCHES BETWEEN. THEN INSTALL (2) SHELVES EVERY 10th NOTCH, 9 NOTCHES BETWEEN & (1) SHELF IN 17th NOTCH, 16 NOTCHES BETWEEN (5 SHELVES) EMPLOYEE UNIT — NO SHELF AT BTM. FROM TOP SHELF, INSTALL (1) SHELF AT 8th NOTCH, 7 NOTCHES BETWEEN. THEN INSTALL (2) SHELVES EVERY 10th NOTCH, 9 NOTCHES BETWEEN & (1) SHELF IN 14th NOTCH, 13 NOTCHES BETWEEN (5 SHELVES) ©FROM BTM SHELF, INSTALL (1) SHELF W/ 25 NOTCHES BETWEEN & THEN (2) SHELVES EVERY 10th NOTCH, 9 NOTCHES BETWEEN. (5 SHELVES) (marketing) FROM BTM SHELF, INSTALL (1) SHELF W/ 17 NOTCHES BETWEEN & THEN A SHELF EVERY 9th NOTCH, 8 NOTCHES BETWEEN. (7 SHELVES) (supplies) INSTALL A SHELF AT TOP & BOTTOM OF EACH UNIT, UON. SEE FLOOR PLAN FOR LOCATION OF SHELVING TYPES. BUMPER AND WHEEL SET NOTES FOR MOVABLE STORAGE INSTALL (2) BUMPERS ON ONE SIDE OF THE BASE WITH (2) SCREWS. INSTALL (1) WHEEL ASSEMBLY WITH (2) BOLTS AND SPLIT LOCK WASHERS. (4) REQUIRED PER BASE. FOR MOVABLE HANGING UNITS; DRILL .169 DIA. HOLE AT POINT "Y", 5-1/8" FROM EXISTING HOLE ON BASE. DO THIS AT ALL FOUR BUMPER LOCATIONS, TWO ON EACH SIDE. ATTACH (1) BUMPER TO EACH OF (4) BUMPER EXTENSION WITH (1) SCREW ATTACH BUMPER ASSEMBLY TO BASE USING (2) SCREWS. INSTALL (2) PER SIDE. INSTALL (1) WHEEL ASSEMBLY WITH (2) BOLTS AND SPLIT LOCK WASHERS. 4 REQUIRED PER BASE ASSEMBLY. tole]`••TIFENIAMM NOT TO SCALE A5 SCALE 3/4" = 1'-0" GROSS BRACING NOTES: 1. SEE CROSS BRACING FREQUENCY DETAIL FOR HIGH/MIDDLE/LOW BRACES IN NON—SEISMIC ZONES. 2. BACK—TO—BACK RUNS CAN SHARE BRACES IF UPRIGHTS ARE CONNECTED PER MFR'S SPECIFICATIONS. CROSS11 10 • ONLY) DEPIII k .z PATRICK G. BLEES sd t'it architecture . planning a interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRIC E C ITECT /- GNATURE 10/9/15 DATE ISSUED 031848-1 REG. NO. G.H.Bass OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE .#7 STORE #4197 SHEET TITLE: DETAILS REVISIONS: NO: DATE: BY: PROJECT N0: 15101.020 DRAWN BY: OMC A 5 COPYRIGHT PATRICK G. BLEES, AIA 2015 DE—TAGGER, MOUNT 2" BACK FROM/t- FRONT OF PULL OUT TRAY 16 F14TOP-8 CASHWRAP COUNTERTOP (2 PIECES) w F14CTR—L F1 4C ADJUSTABLE SHELVES: SHIFT AS NECESSARY TO FIT EQUIPMENT (TYP ALL UNITS) B REAR ELEVATION I F14TOP—B CASHWRAP COUNTERTOP (2 PIECES) (FRONT EUVATION V - CASHWRAP DETAILS SCALE 1/2w = 1'-0" . Zvi i R :4 1 is •. SCALE 1/2w = 1'-0" DE—TAGGER, MOUNT 2" BACK FROM FRONT OF PULL OUT TRAY F14CTR—R REMOVABLE PANEL (ADA) NO CONDUIT FROM SLAB BELOW THIS UNIT 2Xz"O PASSTHRU HOLES IN TOP OF CASHWRAP Will ;W*17003 Y ,t NOTE: FITTING ROOM FOYER SIGNAGE TO BE CENTERED OVER DOOR OPENING. SPACING BETWEEN LETTERS IS 1/4" TYP. N ROOM FITTING ROOM FOYER BEYOND SCALE 1' = 1 °-O" PARTITION, SEE PLAN T.O. STANDARI PARTITION, SEE PLAN i 10'-0" AFF WD SHELF M 3/4" C -LINE STANDARD € MTL BRACKET METAL SHELF BRACKET 3/4" C—LINE STANDARD ATTACHMENT (TYP BOTH SIDES) VA WD SHELF 4" VINYL BASE 4713/16' / STORAGE SHELVING GENERAL NOTES 1. GC TO ASSEMBLE AND INSTALL TENANT FURNISHED STORAGE SYSTEM (12/2A, 12/26, 12/2C, 12/2G) (UPRIGHTS, SHELVES, MISCELLANEOUS ACCESSORIES, ETC.) 2. EACH 10'-0" HIGH SHELVING UNIT EXCEPT MANAGER & EMPLOYEE DESK UNITS ARE TO BE ASSEMBLED WITH ONE (1) SHELF AT TOP AND ONE (1) SHELF AT BOTTOM UON. 3. SEE 9/A5 FOR 12/28, 12/2C. 4. STORAGE SYSTEM NOT ATTACHED TO WALLS, SECURE TO FLOOR PER MFR'S SPECIFICATIONS. 5. FIELD VERIFY VERTICAL AND HORIZONTAL CLEARANCES. 6. LEAVE EXTRA PARTS AT STORE FOR FUTURE USE. 10'--01' STORAGE SHELVING LEGEND n FROM BTM SHELF, INSTALL A SHELF EVERY 12th NOTCH, 11 NOTCHES BETWEEN (6 SHELVES) © FROM BTM SHELF, INSTALL (6) SHELVES EVERY 8th NOTCH, 7 NOTCHES BETWEEN. FROM TOP SHELF INSTALL (1) SHELF IN 11TH NOTCH, 10 NOTCHES BETWEEN (8 SHELVES) (accessories) ©FROM BTM SHELF, INSTALL (1) SHELF AT 7th NOTCH, 6 NOTCHES BETWEEN. THEN INSTALL (4) SHELVES AT EVERY 6th NOTCH, 5 NOTCHES BETWEEN. THEN INSTALL A SHELF EVERY 18th NOTCH, 17 NOTCHES BETWEEN WITH 4 HANGROD ASSEMBLIES. (7 SHELVES — 4 HANGRODS) (garments). PROVIDE 6 ADDITIONAL HANG RODS AND 12 ADDITIONAL BRACKETS IN THE MOST COMMON WIDTH. FROM BTM SHELF, INSTALL 2 SHELVES, ONE AT EVERY 17th NOTCH, 16 NOTCHES BETWEEN AND 2 HANGROD ASSEMBLIES BETWEEN EACH PAIR OF SHELVES. THEN INSTALL ONE SHELF AT EVERY 13th NOTCH, 12 NOTCHES BETWEEN (5 SHELVES — '4 HANG RODS) (hangers) MANAGER UNIT — NO SHELF AT BTM. FROM TOP SHELF, INSTALL (1) SHELF AT 8th NOTCH, 7 NOTCHES BETWEEN. THEN INSTALL (2) SHELVES EVERY 10th NOTCH, 9 NOTCHES BETWEEN & (1) SHELF IN 17th NOTCH, 16 NOTCHES BETWEEN (5 SHELVES) EMPLOYEE UNIT — NO SHELF AT BTM. FROM TOP SHELF, INSTALL (1) SHELF AT 8th NOTCH, 7 NOTCHES BETWEEN. THEN INSTALL (2) SHELVES EVERY 10th NOTCH, 9 NOTCHES BETWEEN & (1) SHELF IN 14th NOTCH, 13 NOTCHES BETWEEN (5 SHELVES) ©FROM BTM SHELF, INSTALL (1) SHELF W/ 25 NOTCHES BETWEEN & THEN (2) SHELVES EVERY 10th NOTCH, 9 NOTCHES BETWEEN. (5 SHELVES) (marketing) FROM BTM SHELF, INSTALL (1) SHELF W/ 17 NOTCHES BETWEEN & THEN A SHELF EVERY 9th NOTCH, 8 NOTCHES BETWEEN. (7 SHELVES) (supplies) INSTALL A SHELF AT TOP & BOTTOM OF EACH UNIT, UON. SEE FLOOR PLAN FOR LOCATION OF SHELVING TYPES. BUMPER AND WHEEL SET NOTES FOR MOVABLE STORAGE INSTALL (2) BUMPERS ON ONE SIDE OF THE BASE WITH (2) SCREWS. INSTALL (1) WHEEL ASSEMBLY WITH (2) BOLTS AND SPLIT LOCK WASHERS. (4) REQUIRED PER BASE. FOR MOVABLE HANGING UNITS; DRILL .169 DIA. HOLE AT POINT "Y", 5-1/8" FROM EXISTING HOLE ON BASE. DO THIS AT ALL FOUR BUMPER LOCATIONS, TWO ON EACH SIDE. ATTACH (1) BUMPER TO EACH OF (4) BUMPER EXTENSION WITH (1) SCREW ATTACH BUMPER ASSEMBLY TO BASE USING (2) SCREWS. INSTALL (2) PER SIDE. INSTALL (1) WHEEL ASSEMBLY WITH (2) BOLTS AND SPLIT LOCK WASHERS. 4 REQUIRED PER BASE ASSEMBLY. tole]`••TIFENIAMM NOT TO SCALE A5 SCALE 3/4" = 1'-0" GROSS BRACING NOTES: 1. SEE CROSS BRACING FREQUENCY DETAIL FOR HIGH/MIDDLE/LOW BRACES IN NON—SEISMIC ZONES. 2. BACK—TO—BACK RUNS CAN SHARE BRACES IF UPRIGHTS ARE CONNECTED PER MFR'S SPECIFICATIONS. CROSS11 10 • ONLY) DEPIII k .z PATRICK G. BLEES sd t'it architecture . planning a interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT. PATRIC E C ITECT /- GNATURE 10/9/15 DATE ISSUED 031848-1 REG. NO. G.H.Bass OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE .#7 STORE #4197 SHEET TITLE: DETAILS REVISIONS: NO: DATE: BY: PROJECT N0: 15101.020 DRAWN BY: OMC A 5 COPYRIGHT PATRICK G. BLEES, AIA 2015 DECK: U.L. #HW -D-0001 NOTE: USE SLIP CONNECTION AT ALL LOCATIONS WHERE WALL: U.L. #U419 PARTITIONS ARE THRU TO STRUCTURE. FIRE RATING NOT REQUIRED AT ALL WALLS, SEE PLAN FOR RATED WALLS. WALL CONNECTION AT DECK A� SCALE 3" 1'-0" 20 GA MET STUDS AT 16" OC MAX. BRIDGING PER STUD MANUFACTURER RECOMMENDATIONS 5/8, TYPE 'X" GBD 20 GA CHANNEL SHAPED GALV STEEL RUNNER WITH 1" MIN LEGS, ATTACHED TO FLOOR W/ FASTENERS @ 24" OC MAX PER `U.L. #U419 & ICC -ESR #2269 & I.C.B.O. #2388. #10 TEK SCREWS (1 PER SIDE) AT EACH STUD PER ICC -ESR #1976. CONC SLAB, SEE SHEET Al. WALL CONNECTION AT SLAB A5.1 SCALE 3" 1'-0" MINIMIZE TRENCH WIDTH TO ACCOMMODATE UNDERSLAB WORK. COORDINATE LOCATION AND REQUIREMENTS WITH ELECTRICAL, PLUMBING AND FIXTURES AS REQUIRED. CUT THROUGH SLAB AND VAPOR BARRIER UNDERDIG SLAB. OVERLAP NEW 4" VAPOR BARRIER 4" OR BARRIER MFG MIP RECOMMENDATIONS OVER EXG BARRIER PIECE AND TAPE PER MFG. 4" ANY REPAIRS TO VAPOR BARRIER TO BE dIN INSPECTED.. PRIOR TO BACKFILL 1, TAPE SEAM —NEW CONDUIT OR PLUMBING DOWEL IN REBAR TO MATCH EXG SLAB REINFORCEMENT 01 0 Ln r 3 TRENCH DETAIL A5.1 SCALE 3/4" = 1'-0" O N OJ L ul 0 0 d C L 0 N C •3 0 L WE 0 J Ll I L0 C) a 4 VCT TO CONCRETE m A5.1 SCALE 6" 1'-0" i TRIP #48 -GREY t PATRICK WALL TYPE PER PLAN 05 G. BLEES (1/4 1B STEEL PLATE) 1B (3" x 3" x 1/4" TUBE) architecture ' 1B planning Interiordesign 26 (20 GAUGE) 8, S' 800 T ICK G. BLEES EES, NAR U TIE CT 09 WALLTYPE MINNEAPOLIS, MN 55401-1148 1 (ALL SIDES) HONE: (612) 547-1300 FAX: (612) 547-1301 PER PLAN E—MAIL: info@cmarch.com -77 CONT 20 GA BOTTOM TRACK = ATTACH TO FLOOR W/HILTI "X—U" N CONTACT: ANTHONY JOHNSON SHOT PINS @ 16" O.C. (ICC ESR r: ajohnson®cmarch.com #2269 & I.C.B.O. #2388) _ ATTACH TRACK TO STUD AT CONSULTANTS. EACH FLANGE W/ #12x14 3/8" DIA BOLTS ELEC PLBG SCREWS EACH SIDE. AT 1 09 8„ W/ WASHERS MECH EMANUELSON PODAS,INC TOP AND BOTTOM TRACK. . 10401 BREN RD EAST NOTES: MINNETONKA, MN 55343 q Tx a v 03 11 1. TOP PLATE IS SIMILAR. (952) 930-0050 4 2. WELD TUBE TO TOP ,,s., AND BOTTOM PLATES. _ 5 VERTICAL WALL SECTION 9 PLAN AT SCREENWALL POST A5.1 SCALE 1 1/2" = 1'-0" A5.1 SCALE 3" 1'-0" WALL TYPE.PER PLAN 09 1 3/8" DIA BOLTS W/ WASHERS & NUTS SEAL: T.O. POST 5'-0" AFF 05(20 GA RUNNERS) j�rzcDA(?� y�\ 1( G. y. 0B (3" x 3" x 1/4" TUBE) ' eQG ) �tf J, i. '�,5m 1 o SECTION AT SCREENWALL POST y�! A5A SCALE 3" = 1'-0" \ fi Q318s18 v — rf of NE raj 5 IT IS A VIOLATION OF THE LAW FOR ANY A6 PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE 8„ 8„ DIRECTION OF A LICENSED ARCHITECT. NOT USED05 B (20 GA RUNNERS) PATRICK BLEES A C 4 ECT SIGNATURE SECURE TO 20 GA METAL STUDS 10/9/15 DATE ISSUED 031848-1 o OB (3" x 3" x 1/4" TUBE) REG. NO. Ln3 11""(CONT 20 GA RUNNER) as - , 3/8 G.H.BassDIA BOLTS W/ WASHERS 3/8 EXPANSION ANCHORS IN FLOOR.'CO• COORDINATE WITH LANDLORD ON SITE. 11 ELEVATION AT SCREENWALL POST OUTLETS AT A5.1 SCALE 1 1/2" = 1'-0" LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 NOT USED 4 1TE. 44 --'E METAL OTHRESHLD AT CONCRETE SCALE 6" = 1'-0" STORE #4197 _T EXG DECK FP11 IYILIiI IIYI11Vf I FASTEN TO BOTTOM CHORD OF JOIST W/ CLAMP, CLIP, CLEAT. UNISTRUT BEAM P1 LIGHTING TRACK THREDDED ROD P1 LY TO UNISTRUT RT UNISTRUT BEAM P1 --- --- — -- — — — — — — — — — CL` OF TRACK @ 10'-0 AFF ii LIGHTING TRACK !! TRACK HEAD TRACK LIGHT- MOUNTING ` DETAIL SCALE 1 1/2 = 1'-0" SHEET TITLE: DETAILS REVISIONS: NO: DATE: BY: PROJECT NO: 15101.020 DRAWN BY: OMC COPYRIGHT PATRICK G. BLEES, AIA 2015 Q 0 PROVIDE NEOPRENE DECK PROVIDE FIRE STOP ' 6 CLOSURE WHEN NON -RATED CLOSURE WHEN FIRE RATED PARTITION IS PERPENDICULAR PARTITION IS TO DECK RIB. PERPENDICULAR TO DECK RIB. 0 25 GA RUNNER WITH 2" " t y LONG LEGS ATTACHED _1` r+ t `'3� + „z;x; EXISTING rn TO METAL DECK WITH ROOF 0 3/8' FRAMING SCREWS STRUCTURE I STANDARD RUNNER --- ----- ----- ---- B.O. DCK FREE TO SLIDE IN VERIFYEHEIGHT r LARGER TRACK o 0 2 1/2" X 2 1/2" X 255/8" TYPE "X" GBD ON GA GALV STEEL L W/ ~ BOTH SIDES OF METAL 5/8" TYPE "X" CBD. STUDS TO BE 5/8" PER BELOW METAL DECK, DO 20 GA MET STUDS AT PL N NOT ATTACH TO 2" LONG 16" OC MAXTO BE 1" LEG RUNNER. LESS IN LENGTH THAN BRIDGING PER STUD TOTAL HEIGHT OF WALL MANUFACTURER RECOMMENDATIONS DECK: U.L. #HW -D-0001 NOTE: USE SLIP CONNECTION AT ALL LOCATIONS WHERE WALL: U.L. #U419 PARTITIONS ARE THRU TO STRUCTURE. FIRE RATING NOT REQUIRED AT ALL WALLS, SEE PLAN FOR RATED WALLS. WALL CONNECTION AT DECK A� SCALE 3" 1'-0" 20 GA MET STUDS AT 16" OC MAX. BRIDGING PER STUD MANUFACTURER RECOMMENDATIONS 5/8, TYPE 'X" GBD 20 GA CHANNEL SHAPED GALV STEEL RUNNER WITH 1" MIN LEGS, ATTACHED TO FLOOR W/ FASTENERS @ 24" OC MAX PER `U.L. #U419 & ICC -ESR #2269 & I.C.B.O. #2388. #10 TEK SCREWS (1 PER SIDE) AT EACH STUD PER ICC -ESR #1976. CONC SLAB, SEE SHEET Al. WALL CONNECTION AT SLAB A5.1 SCALE 3" 1'-0" MINIMIZE TRENCH WIDTH TO ACCOMMODATE UNDERSLAB WORK. COORDINATE LOCATION AND REQUIREMENTS WITH ELECTRICAL, PLUMBING AND FIXTURES AS REQUIRED. CUT THROUGH SLAB AND VAPOR BARRIER UNDERDIG SLAB. OVERLAP NEW 4" VAPOR BARRIER 4" OR BARRIER MFG MIP RECOMMENDATIONS OVER EXG BARRIER PIECE AND TAPE PER MFG. 4" ANY REPAIRS TO VAPOR BARRIER TO BE dIN INSPECTED.. PRIOR TO BACKFILL 1, TAPE SEAM —NEW CONDUIT OR PLUMBING DOWEL IN REBAR TO MATCH EXG SLAB REINFORCEMENT 01 0 Ln r 3 TRENCH DETAIL A5.1 SCALE 3/4" = 1'-0" O N OJ L ul 0 0 d C L 0 N C •3 0 L WE 0 J Ll I L0 C) a 4 VCT TO CONCRETE m A5.1 SCALE 6" 1'-0" i TRIP #48 -GREY t PATRICK WALL TYPE PER PLAN 05 G. BLEES (1/4 1B STEEL PLATE) 1B (3" x 3" x 1/4" TUBE) architecture ' 1B planning Interiordesign 26 (20 GAUGE) 8, S' 800 T ICK G. BLEES EES, NAR U TIE CT 09 WALLTYPE MINNEAPOLIS, MN 55401-1148 1 (ALL SIDES) HONE: (612) 547-1300 FAX: (612) 547-1301 PER PLAN E—MAIL: info@cmarch.com -77 CONT 20 GA BOTTOM TRACK = ATTACH TO FLOOR W/HILTI "X—U" N CONTACT: ANTHONY JOHNSON SHOT PINS @ 16" O.C. (ICC ESR r: ajohnson®cmarch.com #2269 & I.C.B.O. #2388) _ ATTACH TRACK TO STUD AT CONSULTANTS. EACH FLANGE W/ #12x14 3/8" DIA BOLTS ELEC PLBG SCREWS EACH SIDE. AT 1 09 8„ W/ WASHERS MECH EMANUELSON PODAS,INC TOP AND BOTTOM TRACK. . 10401 BREN RD EAST NOTES: MINNETONKA, MN 55343 q Tx a v 03 11 1. TOP PLATE IS SIMILAR. (952) 930-0050 4 2. WELD TUBE TO TOP ,,s., AND BOTTOM PLATES. _ 5 VERTICAL WALL SECTION 9 PLAN AT SCREENWALL POST A5.1 SCALE 1 1/2" = 1'-0" A5.1 SCALE 3" 1'-0" WALL TYPE.PER PLAN 09 1 3/8" DIA BOLTS W/ WASHERS & NUTS SEAL: T.O. POST 5'-0" AFF 05(20 GA RUNNERS) j�rzcDA(?� y�\ 1( G. y. 0B (3" x 3" x 1/4" TUBE) ' eQG ) �tf J, i. '�,5m 1 o SECTION AT SCREENWALL POST y�! A5A SCALE 3" = 1'-0" \ fi Q318s18 v — rf of NE raj 5 IT IS A VIOLATION OF THE LAW FOR ANY A6 PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE 8„ 8„ DIRECTION OF A LICENSED ARCHITECT. NOT USED05 B (20 GA RUNNERS) PATRICK BLEES A C 4 ECT SIGNATURE SECURE TO 20 GA METAL STUDS 10/9/15 DATE ISSUED 031848-1 o OB (3" x 3" x 1/4" TUBE) REG. NO. Ln3 11""(CONT 20 GA RUNNER) as - , 3/8 G.H.BassDIA BOLTS W/ WASHERS 3/8 EXPANSION ANCHORS IN FLOOR.'CO• COORDINATE WITH LANDLORD ON SITE. 11 ELEVATION AT SCREENWALL POST OUTLETS AT A5.1 SCALE 1 1/2" = 1'-0" LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 NOT USED 4 1TE. 44 --'E METAL OTHRESHLD AT CONCRETE SCALE 6" = 1'-0" STORE #4197 _T EXG DECK FP11 IYILIiI IIYI11Vf I FASTEN TO BOTTOM CHORD OF JOIST W/ CLAMP, CLIP, CLEAT. UNISTRUT BEAM P1 LIGHTING TRACK THREDDED ROD P1 LY TO UNISTRUT RT UNISTRUT BEAM P1 --- --- — -- — — — — — — — — — CL` OF TRACK @ 10'-0 AFF ii LIGHTING TRACK !! TRACK HEAD TRACK LIGHT- MOUNTING ` DETAIL SCALE 1 1/2 = 1'-0" SHEET TITLE: DETAILS REVISIONS: NO: DATE: BY: PROJECT NO: 15101.020 DRAWN BY: OMC COPYRIGHT PATRICK G. BLEES, AIA 2015 1114M IW% i Q GENERAL NOTES 1. Work to be accomplished on these Drawings and the accompanying specifications includes the furnishing of all labor, materials, equipment, and services necessary for the proper completion of all mechanical work. 2. Before submitting a proposal on the work contemplated on these drawings and accompanying specifications, each bidder shall examine the site, check as to the means of making connections to services, and shall become familiar with all the existing conditions and limitations. No extras will be allowed because of the contractor's misunderstanding as to the amount of work involved or his lack of knowledge of any site conditions which may affect his work. Any apparent variance of the plan or specification from existing conditions at the site shall be called to the attention of the Engineer during the bid period so clarification can be made by addendum. 3. Existence of any wires, conduits, pipes, ducts, or other facilities are shown in a general way only. It will be the duty of the contractor to visit the site and make exact determination of the existence of any such facilities prior to the submission of his bid. It is understood that he will be responsible for making the exact determination of the location and condition of such facilities. 4. All required fees, permits, and inspections shall be obtained and/or arranged for by the contractor under the section of the Specifications for which they are required. 5. Regular inspections shall be arranged by the contractor as required by any and all regulations, All charges from regulating agencies for inspections of installations or review of plans and Specifications shall be paid by the contractor. 6. Contractor to provide Certificate of Final Inspection. 7. All materials and workmanship shall comply with all current and applicable codes, specifications, ordinances, laws, regulations, industry standards, and utility company regulations. 8. In case of difference among building codes, specifications, state laws, local ordinances, industry standards, and utility company regulations and the Contract Documents, the most stringent shall govern. Contractor shall promptly notify the Engineer in writing of any such difference. 9. All applicable federal, state, and local laws and ordinances shall be adhered to throughout the construction project. 10. Non -Compliance. Should the contractor perform any work that does not comply with the requirements of the applicable building codes, state laws, local ordinances, industry standards, and utility company regulations, he shall bear all costs arising to correct the deficiencies. 11. Contractor shall initiate, maintain, and supervise all safety pre -cautions required for his work, including regulations of the Occupational Safety and Health Administration (OSHA). 12. Drawings are to scale as noted, but the contractor shall refer to Architectural and Structural Drawings for exact location of partitions, walls, beams, shafts, equipment, etc. 13. Each trade shall obtain drawings and specifications of all other trades and. coordinate his work with all other trades. 14. Drawings show the general arrangement of ductwork, piping, equipment, and appurtenances and shall be followed as closely as actual building construction and work of other trades will permit. Mechanical work shall conform to the requirements shown on all of the drawings. Architectural and Structural Drawings shall take precedence over Mechanical Drawings. Because of the small scale of the Mechanical Drawings, it is not possible to indicate all offsets, fittings, and accessories that may be required. 15. Discrepancies discovered before or after work has started shall be brought to the attention of the Engineer immediately, and the Engineer reserves the right to require minor changes in the work of any contractor to eliminate such discrepancies with no change in contract cost. 16. Plans and specifications are complementary, and what is called for in either one shall be as binding as if called for in both. 17. Where a disagreement exists between the plans and specifications, the item or arrangement of better quality, greater quality, or higher cost shall be included in the bid. 18. Normal use of the facility shall not be disturbed, except within the immediate construction area. All walks, driveways, and entrances shall be kept clear and free of all contractor's equipment, material, and debris at all times. 19. All materials and equipment shall be stored in such a place and in such a manner that a minimum of congestion will result. the placing of such materials and equipment shall be subject to the approval of the owner. 20. Contractor shall thoroughly examine the existing building with regard to what temporary measures he must take in order to permit the owner to occupy specific areas of the building during the various construction phases. in general, systems must remain in use in those designated areas to permit the owner to function in a pre -construction manner. 21. Each contractor shall coordinate work with other trades in the installation of equipment, piping, conduit, and ductwork. 22. HVAC/sheet-metal contractor shall initiate the coordination process by providing reproducible plan drawings showing ductwork and equipment. 23. Drawings to be forwarded to the piping contractor and electrical contractor for inclusion of their systems work. 24. Contractors shall solve all coordination conflicts among themselves when possible. Engineer will arbitrate when necessary, and his judgment will stand, with no additional cost to the owner. 25. Access panels shall be furnished by the trade requiring them and delivered to the general contractor for installation. 26. Access panels shall be as manufactured by Milcor, or approved equal, and of type the is compatible with construction and finish of the wall and/or ceiling 27. Each trade shall perform all cutting and patching necessary in order to perform the work, unless such work has been delegated to the general contractor/another trade. However, special permission shall be obtained from the engineer before cutting structural members or finished materials. All patching shall be performed in such manner as to leave no visible trace and to return the part affected to the condition of undisturbed work. Patching work shall be performed by persons experienced, skilled, and licensed for the particular type of work involved. Inferior work will not be accepted. All holes in masonry shall be drilled with rotary drills. Impact tools shall not be used. 28. Each trade shall bear the expense of all cutting, patching, repairing, or replacing of the work of other trades required because of his fault, error, or tardiness of because of any damage done by him. 29. Each trade shall provide all holes and openings required for his work, unless such holes and openings are shown to be provided on the architectural or structural drawings. 30. Each trade shall remove existing work that is shown, specified, or obviously necessary for completion of his work. Owner shall have the option of retaining any item or material removed under this contract. Items or materials not retained by owner shall become the property of the trade and shall be removed from the premises. 31. Each trade shall periodically clear away all debris, surplus materials, etc., resulting from his work or operations, leaving the job and the equipment furnished under any or all contracts in a clean condition. 32. Each trade shall test the equipment provided and/or installed under the specification and shall demonstrate its proper operation to the owner's operating engineer. 33. Each trade shall furnish, without additional expense to the owner, the services of competent instructors, who will give full instruction in the care, adjustment, and operation and maintenance of all parts of the equipment to the owner's permanent employees who are to have charge of the equipment. 34. HVAC subcontractor shall be responsible for tested & rated fire stop systems for all thru-penetrationof walls, floors & roof assemblies resulting from piping & other work under his contract. refer to specification section for fire stopping for requirements. 35. All wood nailers and other lumber which is installed in contact with metal, concrete, or masonry shall be pressure treated against decay (unless otherwise noted). INDEX TO SHEETS M1 MECHANICAL & PLUMBING TITLE SHEET M2 MECHANICAL & PLUMBING PLANS M3 MECHANICAL & PLUMBING SCHEDULES & DETAILS M4 MECHANICAL & PLUMBING SPECIFICATIONS GRILLE, REGISTER AND DIFFUSER KEY OA 4506/aDIA CFM (INCHES) OR DIFFUSER NECK SIZE 12TYP QUANTITY, NO INDICATION = 1 UNIT DEVICE STYLE, SEE SCHEDULE NOTE: SEE GRILLE, REGISTER AND DIFFUSER SCHEDULE FOR FURTHER DETAILS. PATRICK G. BLEES architecture • planning - interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info0cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MICHAEL A. WEBERT SIGNATURE 10-09-2015 DATE ISSUED 78733-1 REG. NO. nrwAk G.H.nass 10 cr %1W C • OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: MECHANICAL AND PLUMBING TITLE SHEET REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY: MTC M1 COPYRIGHT PATRICK G. BLEES, AIA 2015 MECHANICAL SYMBOL LEGEND DOMESTIC COLD WATER (CW) CONTROL VALVE (TWO-WAY) CONTROL VALVE (THREE-WAY) - H DOMESTIC HARD COLD WATER (CW) -T TEMPERED DOMESTIC HOT WATER (110' F) _ GLOBE ANGLED VALVE - 120- DOMESTIC HOT WATER (120' F) ® FLOW DIRECTION PIPE PITCH DIRECTION RECIRCULATION HOT WATER (CHW) W SANITARY WASTE UNDERGROUND 111 PIPE UNION yy SANITARY WASTE ABOVE GROUND g OR ® IN-LINE PUMP V VENT QA AIR VENT AUTOMATIC - IIWR VENT THRU ROOF -. C1M AIR VENT MANUAL --- --- -+ RPZ VALVE (REDUCED PRESSURE BACKFLOW) G NATURAL GAS -- - - _,_____ _ .-_._... ___ ______ -----_---_ _-._.-_ - _-_-- BFP BACKFLOW PREVENTOR CWS CHILLED WATER SUPPLY --- -- _ -_._- .-------._ __-__.-- -_- -- ---_-_- - © BACKWATER VALVE CWR CHILLED WATER RETURN....... ..._.. - - - - _--- __ -- ..--------- --------- ----_- _...... .. O HOPPER DRAIN OR FLOOR SINK HWS HEATING WATER SUPPLY -- _ - HWR HEATING WATER RETURN o FLOOR DRAIN - - ------ - -- - ------ -- ----------..--- CD CONDENSATE DRAIN PIPING UNION S BREAK IN MATERIAL FOR VISUAL PURPOSES RL LIQUID REFRIGERANT �I DRAIN VALVE RS SUCTION REFRIGERANT -- - OT THERMOSTAT FINISHED FLOOR ELEVATION (DN THERMOSTAT - NIGHT SET BACK O SPAC1. E TEMPERATURE SENS1. OR SIAMESE FIRE DEPT CONNECTION CONNECT TO EXISTING - -- -- OH HUMIDISTATSUPPLY, RETURN AND EXHAUST AIR -- --------- ............. _.._ Co CARBON DIOXIDE SENSOR MOTORIZED DAMPER - -- __ A[� AQUASTAT BD BACKDRAFT DAMPER �- FIRE/SMOKE DAMPER 4PSPRESSURE SWITCH FS FLOW SWITCH - - - SU-® SMOKE DAMPER 4 TEMPERATURE GAUGE ( FIRE DAMPER N.O. NORMALLY OPEN ©-® LOW -LEAK SMOKE DAMPER N.C. NORMALLY CLOSED LORS VOLUME DAMPER (MANUAL) VFD VARIABLE FREQUENCY DRIVES -... ___ __.._ ___ EXHAUST REGISTER iT SENSOR TAP ® CEILING SUPPLY DIFFUSER _ ----- _ ... ® RETURN AIR GRILLE/REGISTER - - - 4 WATER HAMMER ARRESTER WITH Q---- } PRESSURE GAUGE WITH ISOLATION VALVE Y1 - -- RETURN AIR GRILLE/REGISTER WITH SOUND BOOT --0 ELBOW UP (PIPE) ELBOW DOWN (PIPE) I SIDEWALL SUPPLY REGISTER _77 - O TEE UP TEE -OFF THE BOTTOM /DOWN SIDWALL RETURN OR EXHAUST GRILLE O FCO -{ICO CLEANOUT FLOOR / CEILING CLEANOUT FLOOR REGISTER PIPE CAP ECCENTIC REDUCER LINEAR DIFFUSER -{�- CONCENTRIC REDUCER FLEX DUCT pppd FLEXIBLE CONNECTION (PIPE) EXPANSION JOINT (LOOP) - - - - - _`_._ O ROOF (PRV) EXHAUST FAN -�- PIPE ANCHOR _ - CABINET UNIT HEATER ALIGNMENT GUIDES VAV BOX WITH COIL j� CHECK VALVE GATE VALVE GAS COCK VALVE SUPPLY DUCT ELBOW WITH TURNING VANES -.. -- -- ----- ---- --- t-- STANDARD OR LINED DUCT (SUPPLY, RETURN, EXHAUST). T 14x10 DUCT IS LABELED TO INDICATE INTERNAL DUCT DIMENSION. -�- ^rr - STOP &-_WASTE_VALVE - W - (GPM)CIRCUIT BALANCING VALVE SEE SPECIFICATION FOR INSULATION. ..-....... STRAINER------- STRAINER WITH BLOW DOWN --- ---- --- - -- ---- -- -- --- --- -- ,. STANDARD ROUND TAKEOFF (CONICAL BELL MOUTH) WITH VOLUME DAMPER p� PRESSURE REDUCING VALVE - --- AFMS AIR FLOW MEASURING STATION PRESSURE RELIEF VALVE- GAS PRESSURE REGULATOR ISI BALL VALVE--- - ---- .... { WH WALL HYDRANT BUTTERFLY/SHUT-OFF VALE HB HOSE BIBB GLOBE VALVE _._ --- --- ---- - - 4 THERMOMETER / OS&Y VALVE / OS&Y VALVE WIRED --- - - - -- -- -- - - -_ _.. --- -- ----- SOLENOID VALVE QFS FLOW SWITCH -PM) -FLOW STATION --- LIMTNGI 14x1 0 1' DOUBLE WALL (SUPPLY, RETURN, EXHAUST). DUCT IS LABELED TO INDICATE INTERNAL DUCT DIMENSION. FLOW VALVE GENERAL NOTES 1. Work to be accomplished on these Drawings and the accompanying specifications includes the furnishing of all labor, materials, equipment, and services necessary for the proper completion of all mechanical work. 2. Before submitting a proposal on the work contemplated on these drawings and accompanying specifications, each bidder shall examine the site, check as to the means of making connections to services, and shall become familiar with all the existing conditions and limitations. No extras will be allowed because of the contractor's misunderstanding as to the amount of work involved or his lack of knowledge of any site conditions which may affect his work. Any apparent variance of the plan or specification from existing conditions at the site shall be called to the attention of the Engineer during the bid period so clarification can be made by addendum. 3. Existence of any wires, conduits, pipes, ducts, or other facilities are shown in a general way only. It will be the duty of the contractor to visit the site and make exact determination of the existence of any such facilities prior to the submission of his bid. It is understood that he will be responsible for making the exact determination of the location and condition of such facilities. 4. All required fees, permits, and inspections shall be obtained and/or arranged for by the contractor under the section of the Specifications for which they are required. 5. Regular inspections shall be arranged by the contractor as required by any and all regulations, All charges from regulating agencies for inspections of installations or review of plans and Specifications shall be paid by the contractor. 6. Contractor to provide Certificate of Final Inspection. 7. All materials and workmanship shall comply with all current and applicable codes, specifications, ordinances, laws, regulations, industry standards, and utility company regulations. 8. In case of difference among building codes, specifications, state laws, local ordinances, industry standards, and utility company regulations and the Contract Documents, the most stringent shall govern. Contractor shall promptly notify the Engineer in writing of any such difference. 9. All applicable federal, state, and local laws and ordinances shall be adhered to throughout the construction project. 10. Non -Compliance. Should the contractor perform any work that does not comply with the requirements of the applicable building codes, state laws, local ordinances, industry standards, and utility company regulations, he shall bear all costs arising to correct the deficiencies. 11. Contractor shall initiate, maintain, and supervise all safety pre -cautions required for his work, including regulations of the Occupational Safety and Health Administration (OSHA). 12. Drawings are to scale as noted, but the contractor shall refer to Architectural and Structural Drawings for exact location of partitions, walls, beams, shafts, equipment, etc. 13. Each trade shall obtain drawings and specifications of all other trades and. coordinate his work with all other trades. 14. Drawings show the general arrangement of ductwork, piping, equipment, and appurtenances and shall be followed as closely as actual building construction and work of other trades will permit. Mechanical work shall conform to the requirements shown on all of the drawings. Architectural and Structural Drawings shall take precedence over Mechanical Drawings. Because of the small scale of the Mechanical Drawings, it is not possible to indicate all offsets, fittings, and accessories that may be required. 15. Discrepancies discovered before or after work has started shall be brought to the attention of the Engineer immediately, and the Engineer reserves the right to require minor changes in the work of any contractor to eliminate such discrepancies with no change in contract cost. 16. Plans and specifications are complementary, and what is called for in either one shall be as binding as if called for in both. 17. Where a disagreement exists between the plans and specifications, the item or arrangement of better quality, greater quality, or higher cost shall be included in the bid. 18. Normal use of the facility shall not be disturbed, except within the immediate construction area. All walks, driveways, and entrances shall be kept clear and free of all contractor's equipment, material, and debris at all times. 19. All materials and equipment shall be stored in such a place and in such a manner that a minimum of congestion will result. the placing of such materials and equipment shall be subject to the approval of the owner. 20. Contractor shall thoroughly examine the existing building with regard to what temporary measures he must take in order to permit the owner to occupy specific areas of the building during the various construction phases. in general, systems must remain in use in those designated areas to permit the owner to function in a pre -construction manner. 21. Each contractor shall coordinate work with other trades in the installation of equipment, piping, conduit, and ductwork. 22. HVAC/sheet-metal contractor shall initiate the coordination process by providing reproducible plan drawings showing ductwork and equipment. 23. Drawings to be forwarded to the piping contractor and electrical contractor for inclusion of their systems work. 24. Contractors shall solve all coordination conflicts among themselves when possible. Engineer will arbitrate when necessary, and his judgment will stand, with no additional cost to the owner. 25. Access panels shall be furnished by the trade requiring them and delivered to the general contractor for installation. 26. Access panels shall be as manufactured by Milcor, or approved equal, and of type the is compatible with construction and finish of the wall and/or ceiling 27. Each trade shall perform all cutting and patching necessary in order to perform the work, unless such work has been delegated to the general contractor/another trade. However, special permission shall be obtained from the engineer before cutting structural members or finished materials. All patching shall be performed in such manner as to leave no visible trace and to return the part affected to the condition of undisturbed work. Patching work shall be performed by persons experienced, skilled, and licensed for the particular type of work involved. Inferior work will not be accepted. All holes in masonry shall be drilled with rotary drills. Impact tools shall not be used. 28. Each trade shall bear the expense of all cutting, patching, repairing, or replacing of the work of other trades required because of his fault, error, or tardiness of because of any damage done by him. 29. Each trade shall provide all holes and openings required for his work, unless such holes and openings are shown to be provided on the architectural or structural drawings. 30. Each trade shall remove existing work that is shown, specified, or obviously necessary for completion of his work. Owner shall have the option of retaining any item or material removed under this contract. Items or materials not retained by owner shall become the property of the trade and shall be removed from the premises. 31. Each trade shall periodically clear away all debris, surplus materials, etc., resulting from his work or operations, leaving the job and the equipment furnished under any or all contracts in a clean condition. 32. Each trade shall test the equipment provided and/or installed under the specification and shall demonstrate its proper operation to the owner's operating engineer. 33. Each trade shall furnish, without additional expense to the owner, the services of competent instructors, who will give full instruction in the care, adjustment, and operation and maintenance of all parts of the equipment to the owner's permanent employees who are to have charge of the equipment. 34. HVAC subcontractor shall be responsible for tested & rated fire stop systems for all thru-penetrationof walls, floors & roof assemblies resulting from piping & other work under his contract. refer to specification section for fire stopping for requirements. 35. All wood nailers and other lumber which is installed in contact with metal, concrete, or masonry shall be pressure treated against decay (unless otherwise noted). INDEX TO SHEETS M1 MECHANICAL & PLUMBING TITLE SHEET M2 MECHANICAL & PLUMBING PLANS M3 MECHANICAL & PLUMBING SCHEDULES & DETAILS M4 MECHANICAL & PLUMBING SPECIFICATIONS GRILLE, REGISTER AND DIFFUSER KEY OA 4506/aDIA CFM (INCHES) OR DIFFUSER NECK SIZE 12TYP QUANTITY, NO INDICATION = 1 UNIT DEVICE STYLE, SEE SCHEDULE NOTE: SEE GRILLE, REGISTER AND DIFFUSER SCHEDULE FOR FURTHER DETAILS. PATRICK G. BLEES architecture • planning - interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info0cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MICHAEL A. WEBERT SIGNATURE 10-09-2015 DATE ISSUED 78733-1 REG. NO. nrwAk G.H.nass 10 cr %1W C • OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: MECHANICAL AND PLUMBING TITLE SHEET REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY: MTC M1 COPYRIGHT PATRICK G. BLEES, AIA 2015 .........-= FIRE SPRINKLER NOTES SPRINKLER CONTRACTOR SHALL PROVIDE IN THEIR BIDS: MODIFYING THE EXISTING SPRINKLER SYSTEM, SPRINKLER HEADS, PIPING, ACCESSORIES, ETC FOR NEW & REMOVED CEILINGS, REMOVED & NEW WALLS AND NEW LIGHT FIXTURE AND DIFFUSER LOCATIONS. PRIOR TO BID, SPRINKLER CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, MAIN & BRANCH LOCATIONS, HYDROLIC CALCULATIONS, ETC. SEE;AR HI.TECTURAL, ELECTRICAL, HVAC PLANS FOR ADDITIONAL INFORMATION SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE AS -BUILT DRAWINGSi TO LANDLORD AFTER FINAL INSTALLATION. SPRINKLER CONTRACTOR TO CREATE & SUBMIT DRAWING(S) & HYDRAULIC CALCULATIONS TO BLDG DEPT AS A DEFERRED SUBMITTAL PRIOR TO START OF WORK. LOCATION OF LIGHTS,FIXTURES, AND SOFFITS TAKES PRIORITY OVER SPRINKLER HEAD LOCATION. DEMOLITION NOTES MECHANICAL CONTRACTOR SHALL CAREFULLY COORDINATE DEMOLITION WORK WITH NEW WORK. DISCONNECT AND REMOVE EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, AND PIPING AS NECESSARY TO ALLOW INSTALLATION OF NEW HVAC AND PLUMBING SYSTEMS. COORDINATE DISPOSAL OF MATERIALS WITH GENERAL CONTRACTOR. 100 j 7 EXN EE 1 1= 1 ODIA O 100 GENERAL NOTES CONNECTION TO EXISTING ROOFTOP HVAC SYSTEM IS SUBJECT TO BUILDING DEPARTMENT AND LANDLORD APPROVAL. CONTRACTOR SHALL COORDINATE WITH LANDLORD PRIOR TO INSTALLATION/CONNECTION. i I I OA'10'0- - -r - I I I F2 - I t4' IODIA- _. C 255nu 00.. i 1A 10DIA %i"�.� t5 (TYP) C 1< 4X )260 11 PI I l UUTA RTU— 14, 0 255 VNALIJ V `—� _ ur ,, ..,. DUCTWOR NOTES: 1 NOT PAINT y OF ALL �t4% Q31510D1A CLE DUCTWORK ADO •, T CONSTRUCTON \ j JUST PRIOR TO TURNOVER. - — SF_1124 • NO FLEXIBLE DUCTWORK PERMITTED ON SALES FLOOR.I Oum - I t4' IODIA- _. C 255nu 00.. i 1A 10DIA %i"�.� t5 (TYP) C 1< 4X )260 11 PI "m L PLAN NOTES OROOFTOP UNIT AND ACCESSORIES TO REMAIN. FIELD VERIFY EXACT LOCATION. TENANT CONTRACTOR TO SERVICE AND CLEAN UNIT, REPLACE AND REPAIR PARTS INCLUDING BUT NOT LIMITED TO FANS, BELTS, BEARINGS, DAMPERS, COILS AND MOTORS TO PROVIDE A FULLY OPERATIONAL UNIT TO DELIVER THE DESIGN CFM. REPLACE FILTERS, BALANCE OUTDOOR AIR TO CFM INDICATED IN HVAC EQUIPMENT SCHEDULE. O REMOVE EXISTING ROOFTOP UNIT. FURNISH AND INSTALL NEW ROOFTOP UNIT PER DETAILS 2/0 AND 5/M3 WITH FULLY INSULATED DOWNFLOW ROOF CURB PER LANDLORD REQUIREMENTS. COORDINATE ALL ROOF PENETRATIONS WITH LANDLORD APPROVED ROOFING CONTRACTOR. REFER TO DETAILS AND SCHEDULES ON SHEET M3 FOR ADDITIONAL INFORMATION. pFLEXIBLE DUCT ALLOWED ABOVE ACT LAY -IN CEILING, MAXIMUM LENGTH 5'-0" (TYPICAL). PROVIDE SMOOTH TRANSITION AND PROPER SUPPORTS PER SMACNA. USE FLEXIBLE DUCT FOR FINAL RUN -OUT TO DIFFUSER ONLY. (TYPICAL). OCONTRACTOR TO CONFIRM OPERATION OF DUCT SMOKE DETECTOR PRIOR TO BID. CONTRACTOR SHALL REPLACE DUCT SMOKE DETECTOR IF IT IS NOT FULLY OPERATIONAL OR PROVIDE NEW SMOKE DETECTOR IF IT IS NOT ALREADY EXISTING. O5 CONNECT TO DUCTWORK WITH CONICAL BELL MOUTH SPIN -IN TAKE -OFF WITH VOLUME DAMPER, TYPICAL. 6O FULL SIZE RETURN AIR DUCT WITH 90 DEG. ELBOW WITH 1/2" WIRE MESH TIGHT TO UNDERSIDE OF STRUCTURE. 7OEXISTING TOILET ROOM EXHAUST FAN TO REMAIN. CONTRACTOR TO INSPECT TEST AND VERIFY OPERATION OF FAN. REPLACE EXHAUST FAN AS NECESSARY TO PROVIDE THE CODE REQUIRED MINIMUM EXHAUST. OEXISTING THERMOSTAT TO LOCATED WHERE INDICATED. FIELD VERIFY EXACT LOCATION. COORDINATE WITH ELECTRICAL CONTRACTOR. THERMOSTAT SHALL BE MANUFACTURED AND PROGRAMMED FOR CONTINUOUS FAN OPERATION DURING OCCUPIED HOURS. CONTRACTOR TO INSTALL AT 48" AFF AND WIRE TO EQUIPMENT PER MANUFACTURERS INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL PROGRAM THERMOSTAT SET POINTS. COORDINATE SETTINGS WITH TENANTS PROJECT MANAGER AND LANDLORD REQUIREMENTS. O NEW DUCT SMOKE DETECTOR PER LANDLORD AND LOCAL JURISDICTION REQUIREMENTS. FURNISH AND INSTALL REMOTE TEST KEYED SWITCH WITH AUDIBLE AND VISUAL INDICATORS IN APPROVED LOCATION. VERIFY CONDITIONS IN FIELD PRIOR TO CONSTRUCTION. 10 SHUT-OFF VALVE, 6" DIRT LEG, PRESSURE REGULATOR & UNION FURNISHED AND INSTALLED AT ROOFTOP UNIT CONNECTION, SEE DETAIL 5/M3. FIELD VERIFY CONNECTION TO ROOFTOP UNIT, MODIFY EXISTING PIPING AS REQUIRED AND PROVIDE PIPE SUPPORTS AS APPROVED BY LANDLORD. GAS PIPING IS SIZED PER NFPA 54 BASED ON 330 MBH, 2_0 PSI, AND 150 FT EQUIVALENT LENGTH. FIELD VERIFY EXACT LOCATION, SIZE AND PRESSURE PRIOR TO BID. PAINT GAS PIPING AS REQUIRED BY LANDLORD AND LOCAL UTILITY. COORDINATE ALL REQUIREMENTS WITH LOCAL UTILITY AND LANDLORD PRIOR TO BID. 11 FURNISH AND INSTALL NEW COMMERCIAL 7 -DAY PROGRAMMABLE THERMOSTAT WITH NEW ROOFTOP UNIT. COORDINATE WITH ELECTRICAL CONTRACTOR. THERMOSTAT SHALL BE MANUFACTURED AND PROGRAMMED FOR CONTINUOUS FAN OPERATION DURING OCCUPIED HOURS. CONTRACTOR TO INSTALL AT 48" AFF AND WIRE TO EQUIPMENT PER MANUFACTURERS INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL PROGRAM THERMOSTAT SET POINTS. COORDINATE SETTINGS WITH TENANTS PROJECT MANAGER AND LANDLORD REQUIREMENTS. Q EXISTING CONDENSATE DRAIN P -TRAP TO REMAIN. 1Q FURNISH AND INSTALL FULL SIZE VENTED P -TRAP, SEE DETAIL 4/M3. EXTEND CONDENSATE DRAIN TO NEAREST ROOF DRAIN AS APPROVED BY LOCAL CODE AND/OR LANDLORD. FIELD VERIFY EXACT LOCATION. PROVIDE SPLASH BLOCK AND PIPE SUPPORTS AS APPROVED BY LANDLORD. DROP TO DIFFUSER TO 11'-0". ADJUST DISCHARGE AIR PATTERN NOT TO INTERFERE WITH HANGING 14 LIGHTS. PAINT COLOR DETERMINED BY ARCHITECT. 15 HOLD ALL NEW DUCTWORK AS HIGH AS POSSIBLE/PRACTICAL TIGHT TO BOTTOM OF STRUCTURE. COORDINATE WITH LIGHTS PRIOR TO INSTALLATION, AVOID CONFLICT. PROVIDE TRANSITIONS AS REQUIRED. DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. CLEAN EXPOSED DUCTWORK AT COMPLETION OF ALL CONSTRUCTION JUST PRIOR TO TURNOVER. i 6 TRANSFER AIR SLEEVE AS ABOVE CEILING AS HIGH AS POSSIBLE. iQCONNECT COLD WATER PIPING INTO 1/2" COLD WATER PIPING NEAR TOILET ROOM. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BID. REFER TO RISER DIAGRAMS AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. CONNECT SANITARY LINE INTO 4" SANITARY SEWER NEAR TOILET ROOM. FIELD VERIFY EXACT SIZE, LOCATION AND INVERT ELEVATION PRIOR TO BIDDING, REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3 19 TENANT'S CONTRACTOR TO FURNISH AND INSTALL NEW WATER HEATER (WH) ON PLATFORM ABOVE SERVICE SINK. PLUMBING CONTRACTOR SHALL PROVIDE A 6" DEEP DRAIN PAN. EXTEND DRAIN PAN AND TEMPERATURE AND PRESSURE RELIEF SEPARATELY TO SERVICE SINK. TERMINATE WITH AIR GAP PER LOCAL CODE. SEE DETAIL 4/M3. ® EXISTING PLUMBING FIXTURES TO REMAIN. QPLUMBING CONTRACTOR SHALL BRING ALL EQUIPMENT AND COMPONENTS TO "LIKE -NEW" CONDITION. PROVIDE NEW OR SIMILAR MODEL AND SIZE AS REQUIRED. VERIFY ALL CONDITIONS ON SITE PRIOR TO BID. PLUMBING CONTRACTOR TO REPLACE EXISTING FIXTURE IN SIMILAR LOCATION. MODIFY EXISTING ROUGH -INS AS REQUIRED, FIELD VERIFY ON SITE PRIOR TO BID. CONNECT NEW VENT PIPING INTO 2" VENT NEAR TOILET ROOM. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BIDDING. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. TENANT'S CONTRACTOR TO FURNISH AND INSTALL NEW AIR CURTAINSSF-1 & 5F-2 RECESS MOUNTED IN CEILING AT FRONT ENTRANCES WITH SIDE MOUNTED CONTROL AND LOW VOLTAGE DOOR LIMIT SWITCHES (MODEL 99-018). SUPPORT FROM STRUCTURE PER MANUFACTURER'S SPECIFICATIONS. INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. ROUTE ALL LOW VOLTAGE WIRING CONCEALED IN DOOR FRAME. SEAL ALL WIRE OPENINGS WEATHER TIGHT. STRUCTURAL ELEMENTS THAT PREVENT CONCEALED LOW/ VOLTAGE WIRING IN DOOR FRAME SHALL BE BROUGHT TO ARCHITECTS ATTENTION IMMEDIATELY. 71, PLUMBING PLAN PATRICK G. BLESS architecture - planning - interior design PATRICK G. BLEES, ARCHITECT 300 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC MANUELSON PODAS, INC 10401 BREN RD EAST WNNETONKA, MN 55343 ;952) 930-0050 SEAL: e �of N � r .CQ PF Y. A'6 �•SJ ac C7 4 Peas)() IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MICHAEL A. WEBERT _ SIGNATURE 10-09-2015 DATE ISSUED 78733-1 REG. NO. G.H.Basbj% Coo OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: MECHANICAL AND PLUMBING PLANS REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY: MTC M 2 COPYRIGHT PATRICK G. BLEES, AIA 2015 14 I I i "m L PLAN NOTES OROOFTOP UNIT AND ACCESSORIES TO REMAIN. FIELD VERIFY EXACT LOCATION. TENANT CONTRACTOR TO SERVICE AND CLEAN UNIT, REPLACE AND REPAIR PARTS INCLUDING BUT NOT LIMITED TO FANS, BELTS, BEARINGS, DAMPERS, COILS AND MOTORS TO PROVIDE A FULLY OPERATIONAL UNIT TO DELIVER THE DESIGN CFM. REPLACE FILTERS, BALANCE OUTDOOR AIR TO CFM INDICATED IN HVAC EQUIPMENT SCHEDULE. O REMOVE EXISTING ROOFTOP UNIT. FURNISH AND INSTALL NEW ROOFTOP UNIT PER DETAILS 2/0 AND 5/M3 WITH FULLY INSULATED DOWNFLOW ROOF CURB PER LANDLORD REQUIREMENTS. COORDINATE ALL ROOF PENETRATIONS WITH LANDLORD APPROVED ROOFING CONTRACTOR. REFER TO DETAILS AND SCHEDULES ON SHEET M3 FOR ADDITIONAL INFORMATION. pFLEXIBLE DUCT ALLOWED ABOVE ACT LAY -IN CEILING, MAXIMUM LENGTH 5'-0" (TYPICAL). PROVIDE SMOOTH TRANSITION AND PROPER SUPPORTS PER SMACNA. USE FLEXIBLE DUCT FOR FINAL RUN -OUT TO DIFFUSER ONLY. (TYPICAL). OCONTRACTOR TO CONFIRM OPERATION OF DUCT SMOKE DETECTOR PRIOR TO BID. CONTRACTOR SHALL REPLACE DUCT SMOKE DETECTOR IF IT IS NOT FULLY OPERATIONAL OR PROVIDE NEW SMOKE DETECTOR IF IT IS NOT ALREADY EXISTING. O5 CONNECT TO DUCTWORK WITH CONICAL BELL MOUTH SPIN -IN TAKE -OFF WITH VOLUME DAMPER, TYPICAL. 6O FULL SIZE RETURN AIR DUCT WITH 90 DEG. ELBOW WITH 1/2" WIRE MESH TIGHT TO UNDERSIDE OF STRUCTURE. 7OEXISTING TOILET ROOM EXHAUST FAN TO REMAIN. CONTRACTOR TO INSPECT TEST AND VERIFY OPERATION OF FAN. REPLACE EXHAUST FAN AS NECESSARY TO PROVIDE THE CODE REQUIRED MINIMUM EXHAUST. OEXISTING THERMOSTAT TO LOCATED WHERE INDICATED. FIELD VERIFY EXACT LOCATION. COORDINATE WITH ELECTRICAL CONTRACTOR. THERMOSTAT SHALL BE MANUFACTURED AND PROGRAMMED FOR CONTINUOUS FAN OPERATION DURING OCCUPIED HOURS. CONTRACTOR TO INSTALL AT 48" AFF AND WIRE TO EQUIPMENT PER MANUFACTURERS INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL PROGRAM THERMOSTAT SET POINTS. COORDINATE SETTINGS WITH TENANTS PROJECT MANAGER AND LANDLORD REQUIREMENTS. O NEW DUCT SMOKE DETECTOR PER LANDLORD AND LOCAL JURISDICTION REQUIREMENTS. FURNISH AND INSTALL REMOTE TEST KEYED SWITCH WITH AUDIBLE AND VISUAL INDICATORS IN APPROVED LOCATION. VERIFY CONDITIONS IN FIELD PRIOR TO CONSTRUCTION. 10 SHUT-OFF VALVE, 6" DIRT LEG, PRESSURE REGULATOR & UNION FURNISHED AND INSTALLED AT ROOFTOP UNIT CONNECTION, SEE DETAIL 5/M3. FIELD VERIFY CONNECTION TO ROOFTOP UNIT, MODIFY EXISTING PIPING AS REQUIRED AND PROVIDE PIPE SUPPORTS AS APPROVED BY LANDLORD. GAS PIPING IS SIZED PER NFPA 54 BASED ON 330 MBH, 2_0 PSI, AND 150 FT EQUIVALENT LENGTH. FIELD VERIFY EXACT LOCATION, SIZE AND PRESSURE PRIOR TO BID. PAINT GAS PIPING AS REQUIRED BY LANDLORD AND LOCAL UTILITY. COORDINATE ALL REQUIREMENTS WITH LOCAL UTILITY AND LANDLORD PRIOR TO BID. 11 FURNISH AND INSTALL NEW COMMERCIAL 7 -DAY PROGRAMMABLE THERMOSTAT WITH NEW ROOFTOP UNIT. COORDINATE WITH ELECTRICAL CONTRACTOR. THERMOSTAT SHALL BE MANUFACTURED AND PROGRAMMED FOR CONTINUOUS FAN OPERATION DURING OCCUPIED HOURS. CONTRACTOR TO INSTALL AT 48" AFF AND WIRE TO EQUIPMENT PER MANUFACTURERS INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL PROGRAM THERMOSTAT SET POINTS. COORDINATE SETTINGS WITH TENANTS PROJECT MANAGER AND LANDLORD REQUIREMENTS. Q EXISTING CONDENSATE DRAIN P -TRAP TO REMAIN. 1Q FURNISH AND INSTALL FULL SIZE VENTED P -TRAP, SEE DETAIL 4/M3. EXTEND CONDENSATE DRAIN TO NEAREST ROOF DRAIN AS APPROVED BY LOCAL CODE AND/OR LANDLORD. FIELD VERIFY EXACT LOCATION. PROVIDE SPLASH BLOCK AND PIPE SUPPORTS AS APPROVED BY LANDLORD. DROP TO DIFFUSER TO 11'-0". ADJUST DISCHARGE AIR PATTERN NOT TO INTERFERE WITH HANGING 14 LIGHTS. PAINT COLOR DETERMINED BY ARCHITECT. 15 HOLD ALL NEW DUCTWORK AS HIGH AS POSSIBLE/PRACTICAL TIGHT TO BOTTOM OF STRUCTURE. COORDINATE WITH LIGHTS PRIOR TO INSTALLATION, AVOID CONFLICT. PROVIDE TRANSITIONS AS REQUIRED. DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. CLEAN EXPOSED DUCTWORK AT COMPLETION OF ALL CONSTRUCTION JUST PRIOR TO TURNOVER. i 6 TRANSFER AIR SLEEVE AS ABOVE CEILING AS HIGH AS POSSIBLE. iQCONNECT COLD WATER PIPING INTO 1/2" COLD WATER PIPING NEAR TOILET ROOM. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BID. REFER TO RISER DIAGRAMS AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. CONNECT SANITARY LINE INTO 4" SANITARY SEWER NEAR TOILET ROOM. FIELD VERIFY EXACT SIZE, LOCATION AND INVERT ELEVATION PRIOR TO BIDDING, REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3 19 TENANT'S CONTRACTOR TO FURNISH AND INSTALL NEW WATER HEATER (WH) ON PLATFORM ABOVE SERVICE SINK. PLUMBING CONTRACTOR SHALL PROVIDE A 6" DEEP DRAIN PAN. EXTEND DRAIN PAN AND TEMPERATURE AND PRESSURE RELIEF SEPARATELY TO SERVICE SINK. TERMINATE WITH AIR GAP PER LOCAL CODE. SEE DETAIL 4/M3. ® EXISTING PLUMBING FIXTURES TO REMAIN. QPLUMBING CONTRACTOR SHALL BRING ALL EQUIPMENT AND COMPONENTS TO "LIKE -NEW" CONDITION. PROVIDE NEW OR SIMILAR MODEL AND SIZE AS REQUIRED. VERIFY ALL CONDITIONS ON SITE PRIOR TO BID. PLUMBING CONTRACTOR TO REPLACE EXISTING FIXTURE IN SIMILAR LOCATION. MODIFY EXISTING ROUGH -INS AS REQUIRED, FIELD VERIFY ON SITE PRIOR TO BID. CONNECT NEW VENT PIPING INTO 2" VENT NEAR TOILET ROOM. FIELD VERIFY EXACT SIZE AND LOCATION PRIOR TO BIDDING. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL INFORMATION. TENANT'S CONTRACTOR TO FURNISH AND INSTALL NEW AIR CURTAINSSF-1 & 5F-2 RECESS MOUNTED IN CEILING AT FRONT ENTRANCES WITH SIDE MOUNTED CONTROL AND LOW VOLTAGE DOOR LIMIT SWITCHES (MODEL 99-018). SUPPORT FROM STRUCTURE PER MANUFACTURER'S SPECIFICATIONS. INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. ROUTE ALL LOW VOLTAGE WIRING CONCEALED IN DOOR FRAME. SEAL ALL WIRE OPENINGS WEATHER TIGHT. STRUCTURAL ELEMENTS THAT PREVENT CONCEALED LOW/ VOLTAGE WIRING IN DOOR FRAME SHALL BE BROUGHT TO ARCHITECTS ATTENTION IMMEDIATELY. 71, PLUMBING PLAN PATRICK G. BLESS architecture - planning - interior design PATRICK G. BLEES, ARCHITECT 300 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC MANUELSON PODAS, INC 10401 BREN RD EAST WNNETONKA, MN 55343 ;952) 930-0050 SEAL: e �of N � r .CQ PF Y. A'6 �•SJ ac C7 4 Peas)() IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MICHAEL A. WEBERT _ SIGNATURE 10-09-2015 DATE ISSUED 78733-1 REG. NO. G.H.Basbj% Coo OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: MECHANICAL AND PLUMBING PLANS REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY: MTC M 2 COPYRIGHT PATRICK G. BLEES, AIA 2015 14 a_ Ln 6 N LO 3 v rri 0 0 0 Ki M i r z m `0 0 0 0 J I 0 M m M 0 0 ri r� m r� F_ 0 w 0 o ROOFTOP AIR CONDITIONING SCHEDULE GH Bass - Lake George, NY HEATING: COOLING: IA: 70°F IA: 75°F/50%RH OA: -3°F OA: 89173(DBIWB)°F RTU -1/2 SALES/STOCK ITEM HEAT LOSS LOCAL CONNECTIONS UNIT FAN DATA COOLING DATA HEATING DATA SERVICE ELECTRICAL DATA SIZE FINISH OUTSIDE FAN CEILING EAT LAT TOTAL INPUT OUTPUT VOLTAGE/ UNIT UNIT HSW TITUS 350RL RETURN OPERATING SEE PLAN DB WB DB WB UNIT MFGR MODEL TONS AIRFLOW AIR ESP SPEED POWER CAPACITY CAPACITY CAPACITY PHASE MCA MOCP WEIGHT NOTES ALL MECHANICAL NOTES 144836 1. MOUNT ON PLATFORM ABOVE SERVICE SINK. (CFM) (CFM) (IN WG) (RPM) (HP) (°F) (°F) (°F) (°F) (MBH) (MBH) (MBH) (LBS) (E) RTU -1 CARRIER 48TME008 7.5 3000 750 0.8 80 67 55 54 90 120/180 96 / 144 208 / 3 PH 40.1 45 1,2,3,4 (N) RTU -2 CARRIER 48TC-AO6 5 2000 500 0.8 80 67 55 54 60 120/150 96/117 208/3 PH 28 40 844 5,6 MECHANICAL NOTES 1. EXISTING UNIT TO REMAIN. FIELD VERIFY EXACT LOCATION. 2. SERVICE AND CLEAN UNIT, REPLACE AND REPAIR PARTS INCLUDING BUT NOT LIMITED TO FANS, BELTS, BEARINGS, DAMPERS, COILS AND MOTORS TO PROVIDE A FULLY OPERATIONAL UNIT TO DELIVER THE DESIGN CFM. REPLACE FILTERS AND BALANCE OUTDOOR AIR TO CFM INDICATED. 3. CONTRACTOR MUST VISIT THE SITE PRIOR TO BID -ALL LABOR AND MATERIALS NECESSARY TO PROVIDE THE TENANT WITH THE INTENDED DESIGN SHALL BE INCLUDED IN THE ORIGINAL BASE BID. NO EXCEPTIONS. 4. CONFIRM OPERATION OF EXISTING DUCT -MOUNTED SMOKE DETECTOR AND REMOTE TEST KEYED SWITCH WITH AUDIBLE AND VISUAL INDICATORS. CONTRACTOR TO PROVIDE NEW IF NOT ALREADY EXISTING OR REPLACE IF NOT OPERATIONAL. FIELD VERIFY CONDITIONS ON SITE. PROVIDE COMPLETE SCOPE OF WORK REQUIRED TO MEET CODE. NO EXCEPTIONS. 5. UNIT INCLUDES: BELT DRIVE, ECONOMIZER PACKAGE, BAROMETRIC RELIEF, POWERED OUTLET, NON-FUSED DISCONNECT, 14" ROOF CURB ASSEMBLY, HAIL GUARD, LABEL UNIT "GH BASS SPACE #7" AS REQUIRED BY LANDLORD. 6. RETURN AIR SMOKE DETECTOR FACTORY INSTALLED, WIRED BY CONTRACTOR. PROVIDE REMOTE TEST KEYED SWITCH WITH AUDIBLE AND VISUAL INDICATORS. DIFFUSER, REGISTER & GRILLE SCHEDULE GH Bass - Lake George, NY HEATING: COOLING: IA: 70°F IA: 75°F/50%RH OA: -3°F OA: 89173(DBIWB)°F RTU -1/2 SALES/STOCK ITEM HEAT LOSS LOCAL CONNECTIONS UNIT LOCATION MANUFACTURER MODEL SERVICE TYPE SIZE FINISH NOTES A CEILING TITUS OMNI SUPPLY PLAQUE 24x24 WHITE 1,2 B HSW TITUS 350RL RETURN GRILLE SEE PLAN WHITE MS -1 C DUCT TITUS TMR SUPPLY DIFFUSER 10"DIA NECK, 18 DIA ROUND WHITE 3 MECHANICAL NOTES: 1. NECK/GRILLE SIZE INDICATED ON FLOOR PLANS. 2. VERIFY WITH ARCHITECTURAL PLANS THE FRAME TYPE PLASTER OR LAY -IN FRAME. 3. PROVIDE D-75 OPPOSED BLADE DAMPER. 1. JANITOR MOP SINK, FIAT MODEL MSB -2424 SINK, CHICAGO FAUCET MODEL 540-LD897SWXFCP, 763 MOP HANGER, T HOSE, HOSE HOLDER. PLUMBING FIXTURE SCHEDULE GH Bass - Lake George, NY HEATING: COOLING: IA: 70°F IA: 75°F/50%RH OA: -3°F OA: 89173(DBIWB)°F RTU -1/2 SALES/STOCK ITEM HEAT LOSS LOCAL CONNECTIONS MOTOR TANK UNIT FIXTURE WASTE VENT CW MANUFACTURER HW NOTES CAPACITY (IN WG) (IN) (IN) (IN) WATTS (IN) PHASE WC -1 WATER CLOSET 4 2 1/2 (GAL) - 2 MS -1 MOP SINK 3 11/2 112 WH 1/2 1 MECHANICAL NOTES: DEL -6 6 1. JANITOR MOP SINK, FIAT MODEL MSB -2424 SINK, CHICAGO FAUCET MODEL 540-LD897SWXFCP, 763 MOP HANGER, T HOSE, HOSE HOLDER. 1,500 120 2. AMERICAN STANDARD MODEL CHAMPION PRO - TRIP LEVER OPEN SIDE AWAY FROM WALL. ALL WATER HEATER SCHEDULE GH Bass - Lake George, NY HEATING: COOLING: IA: 70°F IA: 75°F/50%RH OA: -3°F OA: 89173(DBIWB)°F RTU -1/2 SALES/STOCK ITEM HEAT LOSS FAN MOTOR TANK MARK HEATER DATA MANUF. MODEL # MARK LOCATION MANUFACTURER TYPE MODEL# CAPACITY (IN WG) RECOVERY 50522 EWT EWT WATTS VOLTS PHASE DIRECT 6.6 208V/3PH ALL SF -2 FRONT ENTRY MARS PH1272-2U (GAL) (GPH) ALL (°F) (°F) 1. RECESS MOUNTED IN CEILING AT FRONT ENTRANCE, SUPPORT FROM WALL WITH EXTENDED/OFFSET WALL MOUNTING BRACKET KIT PER MANUFACTURER'S SPECIFICATIONS 2. AMCA211 CERTIFIED. 3. SIDE MOUNTED CONTROL PANEL ON AIR CURTAIN WITH LOW VOLTAGE DOOR LIMIT SWITCHES. ROUTE ALL LOW VOLTAGE WIRING CONCEALED IN DOOR FRAME. SEAL ALL WIRE OPENINGS WEATHER TIGHT. STRUCTURAL ELEMENTS THAT PREVENT CONCEALED LOW VOLTAGE WIRING IN DOOR FRAME SHALL BE WH PLATFORM AOSMITH ELEC.TANK DEL -6 6 10 763 40 110 1,500 120 1 ALL MECHANICAL NOTES 144836 1. MOUNT ON PLATFORM ABOVE SERVICE SINK. 36963 2. PROVIDE 6" DEEP DRAIN PAN. EXTEND 3/4" DRAIN TO APPROVED RECEPTOR. TERMINATE WITH AIR GAP. 3. PROVIDE ASME APPROVED TEMPERATURE AND PRESSURE RELIEF VALVE. EXTEND DRAIN TO APPROVED RECEPTOR. TERMINATE WITH AIR GAP. 4. FURNISH AND INSTALL AMTROL THERM-X-TROL MODLEL #ST -5 EXPANSION TANK ON WATER HEATER. FAN SCHEDULE GH Bass - Lake George, NY HEATING: COOLING: IA: 70°F IA: 75°F/50%RH OA: -3°F OA: 89173(DBIWB)°F RTU -1/2 SALES/STOCK ITEM HEAT LOSS FAN MOTOR SENSIBLE (BTUH) MARK LOCATION MANUF. MODEL # MECH NOTES CFM EXTERNAL SP RPM DRIVE AMPS VOLTS 22495 PEOPLE - (IN WG) TYPE 50522 SF -1 FRONT ENTRY MARS PH1272-2U 8,000 1,750 DIRECT 6.6 208V/3PH ALL SF -2 FRONT ENTRY MARS PH1272-2U 8,000 1,750 DIRECT 6.6 208V/3PH ALL MECHANICAL NOTES: 1. RECESS MOUNTED IN CEILING AT FRONT ENTRANCE, SUPPORT FROM WALL WITH EXTENDED/OFFSET WALL MOUNTING BRACKET KIT PER MANUFACTURER'S SPECIFICATIONS 2. AMCA211 CERTIFIED. 3. SIDE MOUNTED CONTROL PANEL ON AIR CURTAIN WITH LOW VOLTAGE DOOR LIMIT SWITCHES. ROUTE ALL LOW VOLTAGE WIRING CONCEALED IN DOOR FRAME. SEAL ALL WIRE OPENINGS WEATHER TIGHT. STRUCTURAL ELEMENTS THAT PREVENT CONCEALED LOW VOLTAGE WIRING IN DOOR FRAME SHALL BE BROUGHT TO ARCHITECTS ATTENTION IMMEDIATELY. 4. FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR. 5. AIR CURTAIN TO HAVE A MINIMUM VELOCITY OF 2 M/S MEASURED AT THE FLOOR. CONTRACTOR TO ADJUST ANGLE AND/OR MOTOR SPEED AS REQUIRED TO OBTAIN THE 2 MIS VELOCITY REQUIRED AT THE FLOOR. HEAT LOSS AND HEAT GAIN CALCULATIONS GH Bass - Lake George, NY HEATING: COOLING: IA: 70°F IA: 75°F/50%RH OA: -3°F OA: 89173(DBIWB)°F RTU -1/2 SALES/STOCK ITEM HEAT LOSS HEAT GAIN SENSIBLE (BTUH) SENSIBLE (BTUH) LATENT (BTUH) TOTAL (BTUH) LIGHTING - 22495 --- 22495 PEOPLE - 28046 22477 50522 VENTILATION 100579 38588 14280 52868 ROOF 20441 18102 --- 18102 WALL 13568 6021 6021 GLASS 6225 9528 --- 9528 INFILTRATION 4023 557 206 763 MISC --- 5034 --- 5034 RTU -112 144836 128370 36963 165333 PIPE SUPPORTS AS APPROVED BY LAN[ DRAIN UNE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN CAPPED CLEAN OUT OPEN ENDS 2" ROOFTOP UNIT EQUIP DRAIN PAN, MUST BE MOUNTED HIGH ENOUGH TO ENSURE CLEARANCE. PITCH AWAY FROM UNIT. TERMINATE AT ROOF DRAIN WITH SPLASH BLOCK AS APPROVED BY LOCAL CODE AND/OR LANDLORD. A�QONDENSATE DRAIN P -TRAP NO SCALE DETAIL VENTILATION SCHEDULE i COPYRIGHT PATRICK G. BLEES, AIA 2015 UNIT OCC AREA MAX MIN PEOPLE MIN OA SUPPLY EXHAUST SQ FT CFM CFM CFM CFM RTU -1 3100 3000 - 47 750 - RTU -2 2579 2000 - 24 500 100 ASHRAE 62.1 VENTILATION REQUIREMENT: (Rp x Pz) + (Ra x Az) = Vbz RETAIL SALES - (7.5cfm x 71 people)+(.12 x 4733 sq ft) = 1100 cfm OA STORAGE - (.12 x 565 sq ft) = 68 cfm OA CIRCULATION - (.06 x 381 sq ft) = 23 cfm OA COORDINATE ALL GAS METER AND SERVICE REQUIREMENTS WITH LOCAL UTILITY AND LANDLORD PRIOR TO BID. MANUFACTURER SUPPLIED DISCONNECT SWITCH UNION, TYPICAL. PAINT GAS PIPING AS REQUIRED BY LANDLORD AND LOCAL UTILITY. SHUT-OFF VALVE PIPE SUPPORTS AS APPROVED \\ BY LANDLORD. 6" MIN. DIRT LEG, HOLD MIN. 2" ABOVE ROOF GAS PRESSURE REGULATOR (MANUFACTURER RECOMMENDED 7"W.C.) PLUMBING CONTRACTOR TO PROVIDE FULL SIZE CONDENSATE DRAIN P -TRAP THRU BASE POWER OPTION UP THRU ROOF CURB. FL ING IS SIZED PER NEPA 54 BASED ON H, 3.0 PSI, AND 150 FT EQUIVALENT FIELD VERIFY EXACT LOCATION, SIZEESSURE PRIOR TO BID. HOOD/BAROMETRIC RELIEF. Y `ROOFTOP HVAC UNIT i COPYRIGHT PATRICK G. BLEES, AIA 2015 COORDINATE ALL]ROOFPENETRATIONS WLANDLORD APPRROOFING ' ROOF.. CONTRA ROOF CURB. TRANSITION AS REQUIRED. ALL CONTROL WIRING UP THRU ROOF CURB, TYPICAL. ROOFTOP UNIT PIPING DETAIL NO SCALE ROOF CURB ADAPTORS MAY BE ME] OOF ALLOWED AS PERMITTED BY LANDLORD. VERIFY REQUIREMENTS ED AND CONDITIONS PRIOR TO BID AND OR. COORDINATE WITH UNIT SUPPLIER. HVAC CONTRACTOR SHALL PROVIDE NECESSARY TRANSITION FROM DUCT TO ROOF TOP UNIT. FIELD VERIFY ROOF OPENING LOCATIONS AND SIZES. DUCTWORK CONNECTION MUST BE TO ROOFTOP UNIT NOT BOTTOM OF CURB, TYP. ROOFTOP UNIT TO SERVE AS COUNTER FLASHING. MANUFACTURES PREINSULATED ROOF CURB OR CURB ADAPTOR. FIELD VERIFY. TREATED WOOD BLOCKING FASTENED TO DECK x= l FOR LEVEE CONDITIONS BY HVAC CONTRACTOR. RIGID INSULATION METAL ROOF DECKING. HVAC CONTRACTOR SHALL CUT OPENINGS IN COORDINATE ROOF OPENINGS, METAL DECK TO ACCOMMODATE SUPPLY AND WITH ROOF CURB, & SHOP RETURN DUCTWORK. DRAWINGS (SUPPLY AND STRUCTURAL RETURN). JOISTS, TYPICAL ROOFTOP UNIT CURB DETAIL NO SCALE HEAT TRAPS WATTS N36 -M1 VACUUM RELIEF VALVE SHUT-OFF VALVE TYP. - UNION TYP.----,---', A.S.M.E APPROVED TEMP. & PRESS. REUEF VALVE PIPED TO APPROVED RECEPTOR. CONTRACTOR TO MOUNT EXISTING WATER HEATER FROM STRUCTURE USING ANGLE IRON SUPPORT STAND AT W-O"AFF. COORDINATE WITH GENERAL CONTRACTOR FOR ATTACHING TO EXISTING STRUCTURE ELECTRIC WAT NONE TROL EXPANSION (2.0 GAL) RUCTURE. EATER MECH CONTR TO FURNISH 6" DEEP SOLDERED SOLID DRIP PAN BELOW HOT WATER HEATER MOUNTED IN CEILING SPACE. EXTEND 3/4" O.W COPPER DRAIN PIPE TO APPROVED RECEPTOR. EXIEND DRAINS SEPARATELY TO APPROVED RECEPTOR. TERMINATE WITFI AIR GAP PER LOCAL CODE. ER HEATER DETAIL DOMESTIC WATER RISER 1° SOUND INSULATION AS GRILI (SEE S SANITARY WASTE RISER NOTE: SEE MECHANICAL PLANS FOR c17c Akin I nn A'nAKI nC troll I CO CEILING RETURN AIR GRILLE RETURN GRILLE DETAIL NO SCALE NOTE:]T 1. CONTRACTOR SHALL REMOVE ALL DUCT LABELS, CLEAN DUCTWORK AND REGISTERS ON EXPOSED DUCTWORK FOR AESTHETICS. 2. NO FLEXIBLE DUCT ALLOWED IN EXPOSED AREAS. 3. NO SADDLE TAPS ALLOWED PROVIDE ROOF JOIST TEE FITTINGS AS NECESSARY. HANGER WIRE 5UELjAT1-, RU_T HANGER ROUND DUCT A EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS DUCT HANGING DETAILS NO SCALE SPIN -IN, CONICAL OR BELL MOUTH TAKE -OFF ROUND RIGID DUCT -N, ELBOW RADIUS 1-1/2 TIMES DUCT DIAMETER AIR DIFFUSER RECTANGULAR OR ROUND SUPPLY AIR DUCT-, I RUNOUT DUCT SIZE SHALL BE SAME AS DIFFUSER NECK DIAMETER UNLESS NOTED OTHERWISE ON DRAWINGS. DIFFUSER TAKE -OFF DETAIL NO SCALE PATRICK G. B L E E S architecture • planning , interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: NI A a , W Q V fiESS10� IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MICHAEL A. WEBERT _ SIGNATURE 10-09-2015 DATE ISSUED 78733-1 --- REG. N0. ----- -- G.H.Bass coo OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: MECHANICAL AND PLUMBING SCHEDULES AND DETAILS REVISIONS: NO: DATE: BY: PROJECT N0: 3633.0036 DRAWN BY: MTC COPYRIGHT PATRICK G. BLEES, AIA 2015 a Ln q- 6 0 N 0 I C: 0 0) 0 U 01 3 v `t 12 M 0 0 ri . ro L a) . 0) 0 as 0 Q) 0 J m m 0 m cD rr1 0 0 ri m 0 ro0 W 0 of n. 24 DIVISION 15000 - MECHANICAL SECTION 15001 - BASIC MECHANICAL REQUIREMENTS A. GENERAL CONDITIONS 1, THE DRAWINGS AND GENERAL CONDITIONS, INCLUDING SUPPLEMENTARY GENERAL CONDITIONS SHALL APPLY TO ALL WORK IN DIVISION 15000. 2. THE CONTRACTOR FOR THIS DIVISION SHALL REVIEW THE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, EXAMINE THE SITE, CHECK AS TO THE MEANS OF MAKING CONNECTIONS TO SERVICES, AND SHALL BECOME FAMILIAR WITH ALL THE EXISTING CONDITIONS AND LIMITATIONS BEFORE SUBMITTING A PROPOSAL. ANY APPARENT VARIANCES OF THE PLAN OR SPECIFICATION FROM THE EXISTING CONDITIONS AT THE SITE SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER DURING THE BID PERIOD SO THAT CLARIFICATION CAN BE MADE BY ADDENDUM. ITEMS KNOWN TO BE INCONSISTENT WITH THE BID DOCUMENTS INTENT MUST BE LISTED AND QUALIFIED ON THE CONTRACTORS BID FORM. NO EXTRAS WILL BE ALLOWED BECAUSE OF THE CONTRACTORS MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR HIS LACK OF KNOWLEDGE OF ANY SITE CONDITIONS WHICH MAY AFFECT HIS WORK. 3. COORDINATION OF SCHEDULING FOR COMPLETION AND ALL INSPECTIONS OF THEIR WORK AND WORK OF SUBCONTRACTORS IS THE RESPONSIBILITY OF THIS CONTRACTOR. 4. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED ON THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, EACH BIDDER SHALL EXAMINE THE SITE, CHECK AS TO THE MEANS OF MAKING CONNECTIONS TO SERVICES, AND SHALL BECOME FAMILIAR WITH ALL THE EXISTING CONDITIONS AND LIMITATIONS. MECHANICAL EQUIPMENT AND SYSTEMS SHOWN AS EXISTING ON THE PLANS HAVE BEEN BASED ON EXISTING DRAWINGS. NO EXTRAS WILL BE ALLOWED BECAUSE OF THE CONTRACTOR'S MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR HIS LACK OF KNOWLEDGE OF ANY SITE CONDITIONS WHICH MAY AFFECT HIS WORK. ANY APPARENT VARIANCE OF THE PLAN OR SPECIFICATION FROM EXISTING CONDITIONS AT THE SITE SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER DURING THE BID PERIOD SO CLARIFICATION CAN BE MADE BY ADDENDUM. 5. INFORMATION FOR ITEMS WHICH MAY AFFECT THE BID ARE LISTED ON THE RESPONSIBILITY SCHEDULE WHICH IS ON THE PLANS. SECTION 15002- GENERAL REQUIREMENTS 1. WORK TO BE ACCOMPLISHED ON THESE DRAWINGS AND SPECIFICATIONS INCLUDES FURNISHING ALL LABOR, MATERIAL, EQUIPMENT AND SERVICES FOR THE COMPLETION OF ALL MECHANICAL WORK. ALL MECHANICAL WORK UNLESS NOTED TO BE SPECIFICALLY BY THE LANDLORD IS THE RESPONSIBILITY OF THIS CONTRACTOR. 2. THIS CONTRACTOR AND THEIR SUB CONTRACTORS SHALL WORK CLOSELY WITH THE TENANT PROJECT MANAGER FOR COORDINATION OF TRADES AND COMPLETION N OF THE PROJECT. 3. PLANS SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER ONE SHALL BE AS BINDING AS IF CALLED FOR IN BOTH. ANY ITEM OR LABOR THAT IS NECESSARY TO COMPLETE THE WORK AND IS TYPICALLY INCLUDED IN SIMILAR WORK SCOPE SHALL BE FURNISHED AND INSTALLED AS PART OF THE CONTRACT WHETHER OR NOT IT IS SHOWN ON THE PLANS OR IN THE SPECIFICATIONS. 4. WHEN THE INCLUDED DRAWINGS AND/OR SPECIFICATIONS CALL OF ITEMS WHICH EXCEED THE LANDLORDS TENANT CRITERIA OR EXCEED CODE, IT'S THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL THE MORE STRINGENT REQUIREMENTS NOTED ON THE PLANS AND/OR SPECIFICATIONS. IF THE PLANS AND SPECIFICATIONS HAVE DISCREPANCIES BETWEEN THEM, THE CONTRACTOR SHALL ASSUME IN THEIR BID THAT THE MORE STRINGENT ITEM IS REQUIRED AT NO ADDITIONAL COST. 5. ALL PIPING, DUCTWORK AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED TO PRESENT A NEAT AND CLEAN APPEARANCE USING GOOD CONSTRUCTION PRACTICES. EQUIPMENT SHALL BE INSTALLED FOR PROPER ACCESS TO OPERATE, SERVICE AND MAINTAIN THE EQUIPMENT WITHOUT HAVING TO MOVE OTHER EQUIPMENT FOR ACCESS. ANY MECHANICAL EQUIPMENT (OR EXISTING EQUIPMENT TO REMAIN) THAT REQUIRES ACCESS PANELS SHALL HAVE THOSE PANELS FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 6. UNLESS SPECIFICALLY NOTED ON THE PLANS/SPECIFICATIONS ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND BEST QUALITY TO CONFORM TO THE REQUIREMENTS OF THE LANDLORDS TENANT CRITERIA, LOCAL AND STATE CODES GOVERNING THE WORK INVOLVED AND BE MADE BY NATIONALLY RECOGNIZED MANUFACTURES WITH UL LISTINGS AND LABELS. SECTION 15003 - CODES 1. ALL WORK SHALL BE INSTALLED IN CONFORMITY OF THE LANDLORDS TENANT CRITERIA, AND APPLICABLE LOCAL CODES AND ORDINANCES AND STATE STATUTES. ALL REQUIREMENTS OF THE CURRENT PLUMBING CODES, HEATING AND VENTILATION CODES, HEALTH AND SAFETY CODES, NEPA CODES AND ENERGY CODES MUST BE MET. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INQUIRE INTO AND COMPLY WITH ALL LOCAL ORDINANCES AND INCLUDE ANY ADDITIONAL ITEMS NOT NOTED IN THE PLANS/SPECIFICATIONS IN THEIR BID. ANY CHANGES TO THE MECHANICAL SYSTEM AS REQUIRED BY LOCAL, STATE OR TENANT CRITERIA THAT ARE NOT QUALIFIED ON THE CONTRACTORS BID FORM ARE ASSUMED TO BE INCLUDED IN THE ORIGINAL BID AND ADDITIONAL COSTS WILL NOT BE DUE TO COMPLETE THOSE ITEMS AFTER THE CONTRACT IS ISSUED. SECTION 15004 - LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR IS RESPONSIBLE FOR ALL FEES, CHARGES AND OBLIGATIONS FOR OBTAINING PERMITS AND INSPECTIONS FOR PLUMBING, HEATING AND VENTILATION AND FIRE EXTINGUISHING WORK. 2. ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTIONS SHALL BE TURNED OVER TO THE TENANT'S PROJECT MANAGER AT THE COMPLETION OF THE PROJECT. SECTION 15005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. IN ANY CASE WHERE A SPECIFIC NAME OF EQUIPMENT OR MATERIAL IS MENTIONED ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED FOR THE BASE BID. EQUIPMENT OF EQUAL GRADE AND QUALITY WILL BE SUBJECT TO PRIOR APPROVAL BY THE TENANT'S PROJECT MANAGER AND THE ENGINEER IN WRITING THRU THE SHOP DRAWING SUBMITTAL PROCESS. ANY EQUIPMENT INSTALLED WITHOUT WRITTEN APPROVAL WILL BE CHANGED OUT TO THE SPECIFIED EQUIPMENT AT THE CONTRACTORS EXPENSE. 2. MECHANICAL CONTRACTOR SHALL SUBMIT 3 COPIES OF SHOP DRAWINGS TO THE TENANT'S PROJECT MANAGER FOR APPROVAL. IF APPROVED, COPIES WILL BE STAMPED "NO EXCEPTIONS" OR "APPROVED AS NOTED" AND WILL BE RETURNED TO THE CONTRACTOR. IF NOTATIONS AND MARKS INDICATE THAT REVISED INFORMATION IS REQUIRED, THEN CORRECTED INFORMATION SHALL BE SUBMITTED. SECTION 15006 - GUARANTEE 1. THIS CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR AND DEFECTS WHICH MAY DEVELOP IN ANY PART OF THE SYSTEMS CAUSED BY FAULTY WORKMANSHIP, MATERIAL OR EQUIPMENT, AND AGREES TO REPLACE ANY SUCH FAULTY WORKMANSHIP, MATERIAL OR EQUIPMENT DURING A PERIOD OF 12 MONTHS FROM THE DATE OF FINAL ACCEPTANCE WITHOUT ANY COST TO THE OWNER. ANY EXTENDED WARRANTIES (LONGER THAN 12 MONTHS) FOR EQUIPMENT WILL BE NOTED ON THE SCHEDULES, PLANS OR SPECIFICATIONS. 2. EACH PIECE OF EQUIPMENT FURNISHED BY THE CONTRACTOR SHALL HAVE A 12 MONTH WARRANTY FOR MATERIAL AND LABOR AT STARTS UPON THE DATE OF FINAL ACCEPTANCE AS DESIGNATED BY THE TENANT'S PROJECT MANAGER. ALL COSTS FOR THE WARRANTY (MATERIAL AND LABOR) SHALL BE INCLUDED IN THE ORIGINAL BID. SECTION 15007 - RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN AT THE JOB SITE A SET OF DRAWINGS TO BE USED SPECIFICALLY FOR RECORDING CHANGES FROM THE CONTRACT DOCUMENTS. THE INFORMATION SUCH AS VALVES, DUCT AND PIPE DEVIATIONS SHOULD BE DIMENSIONED FROM EASILY RECOGNIZABLE REFERENCE POINTS INDICATING BOTH HORIZONTAL AND VERTICAL DISTANCES. 2. THE CONTRACTOR SHALL SUBMIT A FINAL SIGNED SET OF AS -BUILT DRAWINGS TO THE TENANTS PROJECT MANAGER AT THE COMPLETION OF THE PROJECT. 3. THE CONTRACTOR SHALL SUBMIT TO THE TENANTS PROJECT MANAGER AT THE END OF THE PROJECT (2) COMPLETE HARD BOUND SET OF CATALOG DATA, MANUFACTURES LITERATURE, DETAIL MANUALS COVERING THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT SPECIFIED. SECTION 15008 - DISCREPANCIES IN DOCUMENTS 1. THE DRAWINGS OF PIPING AND DUCTWORK SYSTEMS SHALL BE INSTALLED SUBSTANTIALLY AS SHOWN ON THE PLANS. THE EXACT POSITION OF EACH AND EVERY PIPE, DUCT, OFFSET AND TRANSITION CANNOT BE GIVEN BY SCALING THE DRAWINGS BUT SHALL IN EVERY CASE BE PLACED SO AS TO AVOID INTERFERENCE WITH OTHER WORK. ALL NECESSARY CHANGES IN THE LOCATION OF PIPE OR DUCTWORK FOR ITS PROPER INSTALLATION AND TO AVOID CONFLICT WITH OTHER TRADES SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL CHARGE. SECTION 15009 DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. 3. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. 4. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. 5. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND/OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR AND TENANT PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND TENANT. SECTION 15010 - CUTTING AND PATCHING 1. THIS CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF HIS EQUIPMENT IN THE BUILDING WALLS, PARTITIONS, FLOORS, CEILINGS, ETC., UNLESS OTHERWISE NOTED. ALL CUTTING AND PATCHING SHALL BE SUBJECT TO THE DIRECTION OF THE LANDLORD, ARCHITECT OR ENGINEER. 2. THIS CONTRACTOR SHALL NOT ENDANGER THE STABILITY OF THE STRUCTURE BY CUTTING, DIGGING OR OTHERWISE ALTERING THE STRUCTURE AND SHALL NOT AT ANY TIME CUT OR ALTER WORK OF ANY OTHER CONTRACTOR. 2. PATCHING OF WALLS, FLOORS AND ROOF SHALL BE OF SAME MATERIAL AND WORKMANSHIP OF THE SURROUNDING MATERIAL WITH FINISHED SURFACE APPEARING THE SAME AS THE SURROUNDING AREAS. ALL PATCHING SHALL BE PERFORMED BY WORKMEN SKILLED IN THAT PARTICULAR TRADE. 3. DAMAGE CAUSED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR IN A SUITABLE MANNER ACCEPTABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGERS. SECTION 15011 - SLEEVES 1. THIS CONTRACTOR SHALL INSTALL SLEEVES IN CONNECTION WITH ALL PIPES PASSING THROUGH ALL WALLS, PARTITIONS AND FLOORS. SLEEVES SHALL EXTEND THROUGH FULL THICKNESS OF WALLS AND FLOORS AND SHALL BE CUT FLUSH WITH THE FINISHED SURFACES. SLEEVES IN SLABS SHALL BE CUT 2" ABOVE THE FLOOR SURFACE. 2. ALL SLEEVES SHALL BE 22 GAUGE GALVANIZED STEEL MINIMUM FINISHED WITH A SMOOTH EDGE AND PROPERLY SUPPORTED. 3. CORE DRILLING FLOORS AND WALLS MUST BE COORDINATED WITH THE LANDLORD AND THE TENANT'S PROJECT MANAGER. 4. THIS CONTRACTOR SHALL FURNISH AND INSTALL FIRE STOPPING AT ALL PENETRATIONS THRU RATED FLOORS TO MAINTAIN THE FIRE RATING. 3M FIRE BARRIER SYSTEMS, FLAME SAFE FIRE RETARDANT SYSTEMS, DOW CORNING, SPECSEAL OR EQUAL. THE CONTRACTOR MUST PRESENT UL LISTING DATA SHEETS TO THE TENANT'S PROJECT MANAGER AND LANDLORD TO SHOW THAT THE PENETRATIONS MAINTAIN THE FIRE RATING. SECTION 15012 - HANGERS 1. FURNISH AND INSTALL BRACKETS, BRACES OR REINFORCING ANGLES AS REQUIRED FOR ALL PARTITIONS NOT SUFFICIENT IN THEMSELVES TO SUPPORT PLUMBING FIXTURES OR OTHER EQUIPMENT. 2. PIPING SHALL BE SUSPENDED FROM CONSTRUCTION ABOVE WITH ANGLE IRON, CLAMPS, UNISTRUT, OR HANGER RODS. NO PIPING SHALL BE HUNG FROM OTHER PIPING EXISTING OR NEW. CONTRACTOR SHALL COORDINATE WITH LANDLORD CRITERIA AND ALL CODES. 3. ALL PIPES WHICH ARE SPECIFIED TO BE INSULATED SHALL HAVE PREFABRICATED INSULATED METAL SADDLES SIZED FOR THE INSULATION THICKNESS AND CONTINUOUS INSULATION THROUGH THE HANGER. ALL DISSIMILAR METALS MUST BE SEPARATED WITH DIELECTRIC MATERIAL. DIVISION 15300 - FIRE PROTECTION (IF APPLICABLE) SECTION 15301 - SUMMARY OF WORK 1. THE CONTRACTOR IS REQUIRED TO FURNISH AND INSTALL ALL NECESSARY MATERIAL, EQUIPMENT AND LABOR FOR A WET SPRINKLER SYSTEM TO MEET THE LANDLORDS TENANT CRITERIA AND LOCAL CODES. THE CONTRACTOR SHALL BE REQUIRED TO HAVE DESIGN DRAWINGS COMPLETED BY A CERTIFIED FIRE SPRINKLER DESIGNER AND COPIES OF THE HYDRAULIC CALCULATIONS AND PLANS ALONG WITH SHOP DRAWINGS OF THE HEADS, SHALL BE SUBMITTED TO THE STATE FIRE MARSHALS OFFICE OR LOCAL AUTHORITY HAVING JURISDICTION FOR PLAN REVIEW AND APPROVAL. ON OR BEFORE THE TIME THE PLANS AND CALCULATIONS ARE SUBMITTED TO THE STATE FOR APPROVAL, THEY SHOULD BE SUBMITTED TO THE TENANT'S PROJECT MANAGER AND ENGINEER FOR REVIEW. 2. THE EXISTING WET SPRINKLER SYSTEM SHALL BE REVISED MEET NFPA-13, LOCAL AUTHORITY AND LANDLORDS TENANT CRITERIA. 3. CONTRACTOR IS RESPONSIBLE FOR ALL FEES RELATED PERMITS AND TESTS AND INSPECTIONS. SECTION 15302 - MATERIALS A. SPRINKLER HEADS: 1. ALL SPRINKLER HEADS SHALL BE NEW U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY GRINNELL, RELIABLE, STAR, OR VIKING. 2. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE RATED FOR 1651F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. 3. VERIFY HEAD TYPES AND COLORS WITH TENANT AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY TENANT AND THE LOCAL FIRE PROTECTION OFFICIAL BEFORE INSTALLATION. A. TOILET ROOMS - HARD LID CEILING - CONCEALED HEADS WITH COVERPLATES TO MATCH GYP BOARD FINISH. LAY -IN CEILING - WHITE SEMI -RECESSED HEADS WITH WHITE TRIM IN ACT CEILING. B. STOCKROOM - OPEN CEILING - ROUGH BRONZE UPRIGHT HEAD. LAY -IN CEILING - WHITE SEMI -RECESSED HEADS WITH WHITE TRIM IN ACT CEILING. C. SALES/STOREFRONT - CONCEALED HEADS WITH WHITE HARD LID CEILING - CONCEALED HEADS WITH COVERPLATES TO MATCH GYP BOARD FINISH. LAY -IN CEILING - WHITE SEMI -RECESSED HEADS WITH WHITE TRIM IN ACT CEILING. B. PIPING: 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B-36-10-70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. 5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS. C. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. 1N "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. D. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH OTHER TRADES. E. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN AND INCLUDE ALL COSTS TO RAISE OR RELOCATE EXISTING PIPING TO OBTAIN CEILING HEIGHTS SHOWN ON DRAWINGS. IN NEW CONSTRUCTION THE LANDLORD MAY PROVIDE ONLY A STUB -IN TO THE SPACE. THE CONTRACTOR SHALL CONNECT AND EXTEND NEW PIPING AS REQUIRED. VERIFY ALL REQUIREMENTS PRIOR TO BID. F. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR TENANT'S INSURANCE CARRIER. G. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY THEM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. H. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AND AUTHORITIES HAVING JURISDICTION. DIVISION 15400 - PLUMBING SECTION 15401 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH, INSTALL AND TEST ALL NECESSARY MATERIAL FOR A COMPLETE OPERATING PLUMBING SYSTEM. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION OF THE EXISTING WATER, VENT AND DRAIN LINES TO MAKE CONNECTIONS IN ORDER TO COMPLETE THE WORK AS SHOWN ON THE PLANS. ALL MATERIAL SHALL BE NEW AND SHALL BE INSTALLED FOR PROPER ACCESS FOR SERVINGS. ANY ACCESS PANELS NECESSARY FOR SERVING EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. SECTION 15402 MATERIALS A. THE PLUMBING FIXTURE SCHEDULE IS SHOWN ON PLANS. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURES INSTALLATION INSTRUCTIONS. B. SANITARY PIPING 1. ALL WASTE, VENT AND DRAIN PIPING SHALL BE SERVICE WEIGHT CAST IRON. NO HUB CONNECTIONS SHALL BE USED ABOVE GROUND. HUB AND SPIGOT CONNECTIONS SHALL BE USED BELOW GRADE. GALVANIZED STEEL VENT PIPING MAY BE USED ABOVE GRADE ON 2" OR SMALLER PIPE. NO PVC PIPING WILL BE ALLOWED. 2. ALL WASTE PIPING LOCATED IN THE CEILING OF TENANT SPACES BELOW SHALL BE INSULATED WITH 1" INSULATION WRAP AND ASJ COVERING FOR SOUND INSULATION. 3. CONDENSATE PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBE. INSULATE CONDENSATE PIPING WITH 1" INSULATION WRAP AND ASJ COVERING. C. POTABLE WATER PIPING 1. ALL BELOW GRADE PIPING SHALL BE A SINGLE SECTION "K" SOFT COPPER WITH NO JOISTS BELOW GRADE. ALL PIPING CONNECTIONS WITH DISSIMILAR METALS SHALL HAVE DI -ELECTRIC CONNECTIONS. 2. ALL ABOVE GRADE PIPING SHALL BE TYPE 'L' HARD DRAWN COPPER TUBE WITH SWEAT JOINTS. ALL PIPING CONNECTIONS WITH DISSIMILAR METALS SHALL HAVE DI -ELECTRIC CONNECTIONS. D. INSULATE ALL HOT WATER, COLD WATER AND INTERIOR CONDENSATE PIPING WITH 1" THICK (K=0.23 ® 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. OWENS-CORNING OR EQUAL. E. TRUEBRO MODEL 102W WHITE INSULATION KIT SHALL BE INSTALLED ON ALL TRAPS AND SUPPLY LINES BELOW LAVATORIES TO MEET ADA. F. SIOUX CHIEF 650 SERIES ALL STAINLESS STEEL, OR J.R. SMITH HYDROTROLS SHOCK ABSORBERS SHALL BE INSTALLED IN BOTH HOT AND COLD LINES OF PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. SHOCK ABSORBERS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURES INSTALLATION INSTRUCTIONS. G. THE CONTRACTOR SHALL PROVIDE BALL VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE FOR SERVICING. CONTRACTOR SHALL FURNISH AND INSTALL ACCESS PANELS WHERE NECESSARY FOR PROPER SERVICING. H. MAXIMUM PIPE SUPPORT SPACING OF 5 FEET. CONTRACTOR SHALL PROVIDE NECESSARY SEISMIC BRACING WHERE REQUIRED BY LANDLORD CRITERIA, CODE AND LOCAL AUTHORITIES. I. THE CONTRACTOR SHALL STERILIZE NEW AND EXISTING WATER SYSTEM AS REQUIRED BY LOCAL CODES. CONTRACTOR SHALL INSTALL ANY ADDITIONAL SERVICE VALVES NEEDED IN ORDER TO ISOLATE SYSTEM FOR STERILIZING THE WATER SYSTEM. J. CONTRACTOR SHALL PROVIDE CHROME PLATED ESCUTCHEONS AT ALL EXPOSED PIPE PENETRATIONS IN FINISHED SPACES. K. FLOOR DRAINS WITH DEEP SEAL TRAPS REQUIRED. INSTALL TRAP PRIMERS IN ALL FLOOR DRAINS. LOCATE CLEAN -OUTS IN WALLS AND FLOORS AS REQUIRED TO MEET LOCAL CODES M. CONTRACTOR SHALL PERFORM ALL PIPING PRESSURE/LEAK TESTS BE AS REQUIRED BY LOCAL CODES. N. ALL ROOF FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. ANY ROOF WORK MUST BE DONE BY THE LANDLORDS APPROVED ROOFING CONTRACTOR IN ORDER TO MAINTAIN THE ROOF WARRANTEE. ALL COSTS FOR ROOF WORK MUST BE INCLUDED IN THE BID. 0. CONTRACTOR SHALL FURNISH AND INSTALL WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR AS REQUIRED BY LOCAL UTILITIES REQUIREMENTS. OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. P. GAS PIPING 1. FURNISH AND INSTALL A FUNCTIONAL GAS PIPING SYSTEM WITH NECESSARY VALVES, FITTINGS, UNIONS, DIRT LEGS, REGULATORS, METERS, ETC. REFER TO PLANS FOR EXACT REQUIREMENTS. 2. GAS PIPE SHALL BE SCHEDULE 40 BLACK STEEL WITH MALLEABLE THREADED FITTINGS FOR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 2-1/2" AND LARGER. 3. PROVIDE A SHUT-OFF VALVE, 6" DIRT LEG, AND UNION AT EACH EQUIPMENT CONNECTION. 4. PROVIDE LANDLORD APPROVED PIPING SUPPORTS EVERY 5 FEET OR AS REQUIRED BY LANDLORD OR LOCAL AUTHORITY HAVING JURISDICTION, WHICHEVER IS MORE STRINGENT. 5. PAINT AND PRIME ALL EXPOSED GAS PIPING ON ROOF & EXTERIOR OF BUILDING WITH RUST -INHIBITING PAINT. COORDINATE COLOR REQUIREMENTS WITH LANDLORD. 6. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. 7. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION OF VALVES, FITTINGS, UNIONS, DIRT LEGS, REGULATORS, METERS, ETC. COSTS IN BID. DIVISION 15500 - HEATING, VENTILATING, AIR CONDITIONING SECTION 15501 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH, INSTALL, TEST AND BALANCE ALL NECESSARY EQUIPMENT FOR A COMPLETE WORKING SYSTEM. SEE PLAN FOR DUCTWORK AND SCHEDULES. B. CONTROLS 1. HONEYWELL COMMERCIAL VISION PRO 8000 MODEL TB8220 SERIES 7 -DAY PROGRAMMABLE THERMOSTAT WITH CONTROL FOR UP TO 2 -STAGES OF HEATING AND 2 -STAGES OF COOLING. VERIFY COMPATIBILITY WITH LANDLORDS REQUIREMENTS PRIOR TO INSTALLATION. CONNECT TO LANDLORD ENERGY MANAGEMENT SYSTEM AS REQUIRED. UTILIZE LANDLORD'S CERTIFIED CONTROLS CONTRACTOR. 2. VERIFY COMPLETE OPERATION OF ALL MODES; HEAT, COOL, ECONOMIZER, OCCUPIED, UNOCCUPIED, ETC. CONTRACTOR SHALL PROVIDE FULLY FUNCTIONAL SYSTEM AS APPROVED BY TENANT. ASSIST IN ANY NECESSARY TRAINING AND/OR PROGRAMMING PER TENANTS REQUIREMENTS. 3. COORDINATE CONTROL REQUIREMENTS AND SETTINGS WITH LANDLORD REQUIREMENTS PRIOR TO BID. IF REQUIRED PROVIDE ALL EQUIPMENT TO TIE INTO LANDLORD SYSTEMS. 4. REFER TO PLAN DETAILS AND NOTES FOR ADDITIONAL REQUIREMENTS. SECTION 15502 - MATERIALS A. SEE PLANS FOR SCHEDULES OF EQUIPMENT. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER INSTALLATION INSTRUCTIONS. 1. THIS CONTRACTOR SHALL PROVIDE ALL NECESSARY PARTS AND LABOR INCLUDING BUT NOT LIMITED TO FANS, BELTS, PULLEYS, BEARINGS, DAMPERS, COILS AND MOTORS AS REQUIRED TO OBTAIN A FULLY OPERATIONAL UNIT THAT MEETS OR EXCEEDS THE DESIGN QUANTITIES SET FORTH IN THESE DOCUMENTS INCLUDING BUT NOT LIMITED TO CAPACITY, CFM AND EXTERNAL STATIC PRESSURE. 2. TENANT REQUIRES ALL ROOFTOP EQUIPMENT TO BE LABELED. CONTRACTOR SHALL USE 2-3 INCH BLACK STICK -ON LETTERS (UNLESS LANDLORD CRITERIA REQUIRES OTHERWISE): NEW EQUIPMENT: LABEL ROOFTOP EQUIPMENT WITH EQUIPMENT DESIGNATION, STORE NAME AND SPACE NUMBER - (RTU -1; GH BASS; SPACE XXX) Q AS REQUIRED ED BY LANDLORD. EXISTING EQUIPMENT: LABEL ROOFTOP EQUIPMENT WITH EQUIPMENT DESIGNATION. REPLACE EXISTING STORE NAME AND SPACE NUMBER AS NECESSARY - (RTU -1; GH BASS; SPACE #XXX) AS REQUIRED BY LANDLORD. B. DUCTWORK - FIBERGLASS DUCT BOARD IS NOT APPROVED 1. ALL SUPPLY, RETURN, EXHAUST AND RELIEF DUCTWORK SHALL BE GALVANIZED STEEL SHALL BE MANUFACTURED (GAUGES, REINFORCEMENT AND CONNECTIONS), AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA "HVAC DUCT CONSTRUCTION STANDARDS". 2. ALL ELBOWS SHALL HAVE A MINIMUM THROAT RADIUS OF ONE HALF THE DUCT WIDTH OR SHALL BE PROVIDED WITH TURNING VANES. 3. HANG DUCTWORK FROM STRUCTURE ACCORDING TO SMACNA STANDARDS. CONTRACTOR SHALL BE REQUIRED TO INSTALL SEISMIC BRACING AS REQUIRED BY LANDLORD CRITERIA AND/OR LOCAL CODES. 4. ALL DUCT JOINTS AND LONGITUDINAL SEAMS SHALL BE SEALED WITH A WATER BASED DUCT SEALER, DURO DYNE "DUROSEAL" OR APPROVED EQUAL. 5. PROVIDE FLEXIBLE DUCT CONNECTIONS CONSTRUCTED OF NEOPRENE -COATED FLAMEPROOF FABRIC AT EQUIPMENT INLET AND OUTLET TO ISOLATE VIBRATION. 6. THE FINAL 4 FT OF DUCTWORK TO THE AIR DEVISE MAY BE FLEXIBLE CLASS 1 DUCT WITH R-5 INSULATION AND FOIL VAPOR BARRIER. DUCTWORK MUST MEET LOCAL REQUIREMENTS AND LANDLORDS CRITERIA. 7. THE FIRST 15 FT OF DUCTWORK FROM THE ROOFTOP UNIT SHALL BE INTERNALLY LINED WITH 1 IN FIBROUS GLASS DUCT LINER WITH ANTI -MICROBIAL COATING FOR CONDENSATE AND NOISE. 8. ALL SUPPLY TAKE -OFFS SHALL HAVE AIR SCOOP AND MANUAL VOLUME DAMPER WITH QUADRANT LOCKING HANDLE FOR BALANCING. WHERE DUCTWORK IS LOCATED ABOVE A GYPSUM BOARD CEILING, A CABLE CONTROLLED DAMPER OPERATOR SHALL BE FURNISHED, YOUNG REGULATOR COMPANY OR EQUAL. C. HYDRONIC PIPING 1. THIS CONTRACTOR SHALL FURNISH, INSTALL AND TEST ALL NECESSARY MATERIAL FOR A COMPLETE OPERATING HYDRONIC SYSTEM. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION OF THE EXISTING CHILLED AND HEATING WATER SUPPLY AND RETURN LINES AND VALVES TO MAKE CONNECTIONS IN ORDER TO COMPLETE THE WORK AS SHOWN ON THE PLANS. ALL MATERIAL SHALL BE NEW AND SHALL BE INSTALLED FOR PROPER ACCESS FOR SERVINGS. ANY ACCESS PANELS NECESSARY FOR SERVING EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. 2. PIPING A. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER OR HEATING WATER SHALL BE ASTM A 53/A 53M, BLACK STEEL WITH PLAIN ENDS. ABOVEGROUND HYDRONIC PIPING NPS 2 AND SMALLER SHALL BE TYPE L' DRAWN -TEMPER COPPER TUBING WITH WROUGHT -COPPER FITTINGS, AND SOLDERED JOINTS. ABOVEGROUND HYDRONIC PIPING NPS 2-1/2 AND LARGER SHALL BE SCHEDULE 40 STEEL PIPE WITH WROUGHT -STEEL FITTINGS AND WROUGHT -CAST OR FORGED -STEEL FLANGES AND FLANGE FITTINGS AND WELDED AND FLANGED JOINTS. INSTALL UNIONS IN PIPING NPS 2 AND SMALLER ADJACENT TO VALVES, AT FINAL CONNECTIONS OF EQUIPMENT AND AS INDICATED. INSTALL FLANGES IN PIPING NPS 2-1/2 AND LARGER AT FINAL CONNECTIONS OF EQUIPMENT AND AS INDICATED. ALL PIPING CONNECTIONS WITH DISSIMILAR METALS SHALL HAVE DI -ELECTRIC CONNECTIONS. ALL HYDRONIC PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, AND/OR LANDLORD CRITERIA WHICHEVER IS MORE STRINGENT. B. PREPARE HYDRONIC PIPING FOR TESTING, ACCORDING TO ASME 831.9. FLUSH HYDRONIC PIPING SYSTEMS WITH CLEAN WATER; THEN REMOVE AND CLEAN OR REPLACE STRAINER SCREENS. WHILE FILLING SYSTEM, USE VENTS INSTALLED AT HIGH POINTS OF SYSTEM TO RELEASE AIR. USE DRAINS INSTALLED AT LOW POINTS FOR COMPLETE DRAINING OF TEST LIQUID. ISOLATE EQUIPMENT FROM PIPING. IF A VALVE IS USED TO ISOLATE EQUIPMENT, ITS CLOSURE SHALL BE CAPABLE OF SEALING AGAINST TEST PRESSURE WITHOUT DAMAGE TO VALVE. INSTALL BLINDS IN FLANGED JOINTS TO ISOLATE EQUIPMENT. ISOLATE EXPANSION TANKS AND DETERMINE THAT HYDRONIC SYSTEM IS FULL OF WATER. C. PERFORM THE FOLLOWING TESTS ON HYDRONIC PIPING: SUBJECT PIPING SYSTEM TO HYDROSTATIC TEST PRESSURE THAT IS NOT LESS THAN 1.5 TIMES THE SYSTEM'S WORKING PRESSURE. TEST PRESSURE SHALL NOT EXCEED MAXIMUM PRESSURE FOR ANY VESSEL, PUMP, VALVE, OR OTHER COMPONENT IN SYSTEM UNDER TEST. VERIFY THAT STRESS DUE TO PRESSURE AT BOTTOM OF VERTICAL RUNS DOES NOT EXCEED 90 PERCENT OF SPECIFIED MINIMUM YIELD STRENGTH OR 1.7 TIMES "SE" VALUE IN APPENDIX A IN ASME B31.9, "BUILDING SERVICES PIPING." AFTER HYDROSTATIC TEST PRESSURE HAS BEEN APPLIED FOR AT LEAST 10 MINUTES, EXAMINE PIPING, JOINTS, AND CONNECTIONS FOR LEAKAGE. ELIMINATE LEAKS BY TIGHTENING, REPAIRING, OR REPLACING COMPONENTS, AND REPEAT HYDROSTATIC TEST UNTIL THERE ARE NO LEAKS. PREPARE WRITTEN REPORT OF TESTING. D. PERFORM THE FOLLOWING BEFORE OPERATING THE SYSTEM. OPEN MANUAL VALVES FULLY. INSPECT AIR VENTS AT HIGH POINTS OF SYSTEM AND DETERMINE IF ALL ARE INSTALLED AND OPERATING FREELY (AUTOMATIC TYPE), OR BLEED AIR COMPLETELY (MANUAL TYPE). SET TEMPERATURE CONTROLS SO ALL COILS ARE CALLING FOR FULL FLOW. INSPECT AND SET OPERATING TEMPERATURES OF HYDRONIC EQUIPMENT, SUCH AS BOILERS, CHILLERS, COOLING TOWERS, TO SPECIFIED VALUES. 3. VALVES A. COPPER ALLOY BALL VALVE 2" AND SMALLER: MSS SP -110, TWO-PIECE BRASS OR BRONZE BODY WITH CHROME PLATED BRONZE OR STAINLESS STEEL BALL, PTFE OR TFE SEATS AND 400 PSIG MINIMUM CWP RATING. APOLLO, NIBCO, CRANE OR EQUAL. B. FERROUS -ALLOY BUTTERFLY VALVE 2-1/2" AND LARGER SIZE: MSS SP -67, TYPE I. LUG OR WAFER STYLE WITH BUBBLE TIGHT SHUTOFF, 200 PSI CWP, EPDM LINING AND ALUMINUM ,BRONZE DISC. HAMMOND, NIBCO, CRANE OR EQUAL. C. BRONZE CHECK VALVE 2" AND SMALLER: MSS SP -80, BRONZE BODY WITH BRONZE DISC AND SEAT AND CWP RATING: 200 PSI, D. IRON SWING CHECK VALVE 2 -1/2 -AND LARGER: MSS SP -71, TYPE I. GRAY IRON BODY, ASTM A 126, WITH BOLTED BONNET, BRONZE TRIM AND CWP RATING: 200 PSI. E. CONTROL VALVES: FACTORY FABRICATED, OF TYPE, BODY MATERIAL, AND PRESSURE CLASS BASED ON MAXIMUM PRESSURE AND TEMPERATURE RATING OF PIPING SYSTEM. F. HYDRONIC SYSTEM GLOBE VALVES NPS 2 AND SMALLER: CLASS 125 BRONZE BODY, BRONZE TRIM, RISING STEM, RENEWABLE COMPOSITION DISC, AND SCREWED ENDS WITH BACKSEATING CAPACITY REPACKABLE UNDER PRESSURE. NPS 2-1/2 AND LARGER: CLASS 125 IRON BODY, BRONZE TRIM, RISING STEM, PLUG -TYPE DISC, FLANGED ENDS, AND RENEWABLE SEAT AND DISC. HYDRONIC SYSTEM GLOBE VALVES CONSTRUCTED WITH REPLACEABLE PLUGS AND STAINLESS-STEEL OR BRASS SEATS. DOUBLE -SEATED VALVES WITH BALANCED PLUG, CAGE TRIM PROVIDES SEATING AND GUIDING SURFACES FOR PLUGS ON TOP AND BOTTOM. HYDRONIC SYSTEM GLOBE VALVES SHALL BE SIZED WITH A 3-PSIG MAXIMUM PRESSURE DROP AT DESIGN FLOW RATE OR TWO POSITION: LINE SIZE. TWO-WAY MODULATING: EITHER THE VALUE SPECIFIED ABOVE OR TWICE THE LOAD PRESSURE DROP, WHICHEVER IS MORE. G. THREE-WAY MODULATING: TWICE THE LOAD PRESSURE DROP, BUT NOT MORE THAN VALUE SPECIFIED ABOVE. HYDRONIC SYSTEM GLOBE VALVES SHALL HAVE THE FOLLOWING FLOW CHARACTERISTICS: TWO-WAY VALVES SHALL HAVE EQUAL PERCENTAGE CHARACTERISTICS; THREE-WAY VALVES SHALL HAVE LINEAR CHARACTERISTICS. CLOSE -OFF (DIFFERENTIAL) PRESSURE RATING SHALL BE A COMBINATION OF ACTUATOR AND TRIM SHALL PROVIDE MINIMUM CLOSE -OFF PRESSURE RATING OF 150 PERCENT OF TOTAL SYSTEM (PUMP) HEAD FOR TWO-WAY VALVES AND 100 PERCENT OF PRESSURE DIFFERENTIAL ACROSS VALVE OR 100 PERCENT OF TOTAL SYSTEM (PUMP) HEAD. 3. PIPING SPECIALTIES A. Y -PATTERN STRAINERS: CAST IRON BODY: ASTM A 126, CLASS B, WITH BOLTED COVER AND BOTTOM DRAIN CONNECTION, THREADED ENDS FOR NPS 2 AND SMALLER; FLANGED ENDS FOR NPS 2-1/2 AND LARGER. 20 -MESH STRAINER SCREEN WITH 50 PERCENT OPEN AREA, 125 PSIG CWP RATING, B. STAINLESS-STEEL BELLOW, E CONNECTORS: STAINLESS-STEEL BELLOWS BODY WITH WOVEN, FLEXIBLE, BRONZE, WIRE -REINFORCING PROTECTIVE JACKET. THREADED OR FLANGED TO MATCH EQUIPMENT CONNECTED WITH 3/4 -INCH MISALIGNMENT, 150 PSIG CWP RATING AND 250 DEG F MAXIMUM OPERATING TEMPERATURE, 4. INSULATION A. INSULATE ALL HYDRONIC PIPING FOR CHILLED WATER AND HEATING WATER WITH 1" THICK (K=0.23 0 75 F) PIPE INSULATION COMPLY WITH ASTM C 547, TYPE I, GRADE A, WITH FACTORY -APPLIED ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. OWENS-CORNING OR EQUAL. 5. INSTALLATION A. INSTALL PIPING TO PERMIT VALVE SERVICING. B. INSTALL PIPING TO ALLOW APPLICATION OF INSULATION. C. ALL PIPES SHALL HAVE PREFABRICATED INSULATED METAL SADDLES SIZED FOR THE INSULATION THICKNESS AND CONTINUOUS INSULATION THROUGH THE HANGER. D. ALL DISSIMILAR METALS MUST BE SEPARATED WITH DIELECTRIC MATERIAL. E. SELECT SYSTEM COMPONENTS WITH PRESSURE RATING EQUAL TO OR GREATER THAN SYSTEM OPERATING PRESSURE, F. INSTALL PIPING AT A UNIFORM GRADE OF 0.2 PERCENT UPWARD IN DIRECTION OF FLOW. G. REDUCE PIPE SIZES USING ECCENTRIC REDUCER FITTING INSTALLED WITH LEVEL SIDE UP. H. INSTALL BRANCH CONNECTIONS TO MAINS USING TEE FITTINGS IN MAIN PIPE, WITH THE BRANCH CONNECTED TO THE BOTTOM OF THE MAIN PIPE. FOR UP -FEED RISERS, CONNECT THE BRANCH TO THE TOP OF THE MAIN PIPE. D. TESTING, ADJUSTING, AND BALANCING 1. THE ADJUSTING AND BALANCING OF THE AIR FLOW THROUGHOUT THE FACILITY SHALL BE PERFORMED BY AN NEBB OR AABC CERTIFIED AIR BALANCER AS HIRED BY THE MECHANICAL CONTRACTOR. THE BALANCING SHALL TAKE PLACE AFTER THE FINAL PUNCH LIST. THE BALANCING CONTRACTOR SHALL VERIFY THAT ITEMS ON THE PUNCH LIST EFFECTING THE AIR BALANCE REPORT ARE COMPLETED PRIOR TO STARTING THE AIR BALANCE. THE MECHANICAL CONTRACTOR SHALL PROVIDE ASSISTANCE TO THE TESTING AND BALANCING CONTRACTOR BY MAKING ADJUSTMENTS TO THE SYSTEM AND SYSTEM COMPONENTS REQUIRED FOR ACHIEVING DESIGN PERFORMANCE. 2. CONTRACTOR SHALL SUBMIT COPIES OF BALANCE/TEST REPORT TO TENANT FOR REVIEW PRIOR TO COMPLETION OF PROJECT. IF A CERTIFIED TEST AND BALANCE REPORT IS REQUIRED BY LANDLORD, CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH LANDLORD AND LOCAL AUTHORITY HAVING JURISDICTION, CONTRACT DIRECTLY WITH AN APPROVED TESTING A AND BALANCING AGENCY, AND PROVIDE COMPLETE REPORT TO OWNER AND LANDLORD. 3. THE BALANCE REPORT SHALL BE ON THE AABC NATIONAL STANDARD REPORT FORMS OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B. COPY OF A CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS FOR THIS PROJECT. C. INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. D. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. E. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. F. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. G. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. H. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AND VOLUMES SHALL BE MEASURED AT FULL COOLING WITH MINIMUM OUTSIDE AIR. RETURN/RELIEF/SMOKE EVACUATION AIRFLOW SHALL BE BALANCED AND MEASUREMENTS RECORDED BY PITOT DUCT TRAVERSE AT FULL ECONOMIZER AND POWER EXHAUST. I. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). K. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. ALSO INDICATE IF DIFFUSER IS 3 -WAY OR 2 -WAY. L. FINAL BALANCED GPM AT ALL UNITS FOR CHILLED/HOT/CONDENSER WATER WHEN APPLICABLE. M. CHILLED/HOT/CONDENSER ENTERING AND LEAVING WATER TEMPERATURES WHEN APPLICABLE. N. PRESSURE DROP THROUGH COILS AND CONTROL VALVES WHEN APPLICABLE. PATRICK G. BLEES architecture ^ planning ^ interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MICHAEL A. WEBERT SIGNATURE 10-09-2015 J DATE ISSUED 78733-1 ___ REG. NO. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: MECHANICAL AND PLUMBING SPECIFICATIONS REVISIONS: NO: DATE: BY: PROJECT N0: 3633.0036 --- _ --- DRAWN BY: MTC m COPYRIGHT PATRICK G. BLEES, AIA 2015 `. - - - - - t r<i N rQ PATRICK x q - G. BLEES N architecture • planning at p g •interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 10 MINNEAPOLIS, MN 55401-1148 ``X27 �E 27 All / L-71 PHONE: (612) 547-1300 _ T=FP — FAX: — L 13 612 547 1301 L 27 / E-MAIL: info@cmarch.com ; /CONTACT: ANTHONY JOHNSON / L-15 I _ Al �' 1 �� L-17 ajohnson®cmarch.com L-27 - - - L 27 L-29 CONSULTANTS: - - - L-23 MECH/PLBG/ELEC \\ L-29 EMANUELSON PODAS, INC - _ _ �� 10401 BREN RD EAST r L-27 L-27 r L-24 MINNETONKA, MN 55343 i D _ D (�XG) ® L-26 (952) 930-0050 — — l A �e Li �D e L 2�e 1 r-- L-27 if f �- - 2-_EEXfI L1 -I`-- C A N e i -L=25 --- - - IPNL L' (D7 SWITCH c _ LD25- e -.- Al (EXG) _ �\ LAll O LA 27 11 L L-5 0 L-5 L-27 L-5 NL O LAl D2 ® - L 249, / NL f L 5 -- ------ , \ it M F - LIGHTING CO TACTOR W ENCLOSE COVER /Tl-/_ L I7L7L��7IL- -I�IJL T1Il_Tl L fT11-IZ/I_ /- - J- -- -- - -- - -LG-$0-VO2 W% P CONTACTS. SEAL: /TLS ELQECTRECALLB HELD W/ 120V CONTROL.AM CONTROLLED BY WALL SWITCH. L-5 AD 2 AMP 0 r d" T2(2) T2(2) T2(2) T2(2) T2(2) T2(2) T2(2) T2(2) T2(2) "-'-- LIGHTING CONTACTOR �,N_ L-,3 L-11 T1 L-11 T1 b M 7 AMP 6 LT113 L-11 - L-11 -. Ti L-11 LT113 L-11 LT113 L-11 LT113 j T1 co 4k L-11 T1 L-11 Ti r 11 aff aAMP ® L-13 ® ® L-13 ® L-13 ® ® L-13 ® ® L-13 ® ® L-13 ® ® ® ® ® ® O L1-4 NO SCALE yyr ° 8 8' -� 8' WL_ 8' - �f _ g' g• 8 B 2, z AMP VIA TC T2 T2 � (� 2 43 -„ L-21 ® 4 AMP s O L-11 ® VA TG+�' Ti 8475 sa0 T1 L-13 91 _1 -4 L-19 F2 ® F2 �O F2 ® ® - VIA T P . a 2 ® O F2 ® O F2 U b F2 F2 F2 F2 ® ® L� 11 u6z L-9 L-5 L-9 z aMP�° L-7 z aMP®° L-9 _ IT IS A VIOLATION OF THE LAW FOR ANY b F NL F b 6 F ° F F ° L-9 F b 2 AMPI� L-7 F 2 AMP® L-9 F 2 AMP c Ll ® ® ® ° ® 0 b 0 3 �� WAYPERSON TO UNLESSLTER AN ACTING 1TEM IN ANY UNDER THE L-21 DIRECTION OF A LICENSED ENGINEER. L-21 � ® 8, ® ®, z AMP ® ® ® Q ® ® LX15 T2(4) C L-26 N (EXG) at i 0 E ° 2 aMP F2 Q L-5 VIA TC MATTHEW W. FULTS ® ® L-23 ®O T2(6) (® ® T2(7) ® ® L-5 NL \ SIGNATURE Tl Q L-29 L-2410-09-2015 10-09-2015 L-19 DATE ISSUED 087346-1 T2(6) T2(6) REG. NO. �y F2 L 9 ® L-15 F2 ® F2 L-29 ® LF 7 F2 F2 L-26 ® F2 ® L-25-�25—LD25 - J [] Lp(21 L-7 �b L-7 ° L-9 b ❑�° L-9 b L-7 ° L-9 b ❑ L-7 ° ® ® ° ® F -i. ® ® ® 1 AMP - 2 AMP ® ® O b,-4 ® T2(2) ® L-25 L-25 Li -25 ��01 T1 ® L-26 T1 G.H. L-19 B 2 AMP °° ° � ®, d � '"� � � � i L1-4 TC ® ® T2 (7) ® 6 2�P O 2®P cO 2 AMO ® ® ( ) 2 AMP ° 2 AMP ° b L-23 O L 24 O ® ® O ® O o Q , �� _1(22 cue ® L-25 L-25 L 25 - ® ATG KEYNOTES LIGHTING T2(2) � r r1 OUTLETS AT k` L-21 ® ® X, SIA Tc LAKE GEORGE F2 F2 F2 F2 L-5 ® ® Y O - O ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH ® L 9 b L-7 ° L-9 F b L-7 ° LF 9 F b 7 F 9 LF 7 9 L,A-zP WITHIN 5 FEET OF SIGN IN CONCEALED SPACE. SIGNS FURNISHED BY OTHER. ® � ° b IF b 6 FINAL CONNECTION OF SIGNS BY ELECTRICAL CONTRACTOR. SEE ARCHITECTURAL 1424 STATE R T2(s) T 9 L-29 ® T2(6) ® _ PLANS FOR SIGN LOCATION TO DETERMINE CONDUIT ROUTING AND IF A ROOF T1 3 L-26 3 PENETRATION MAY BE REQUIRED. ROOF PENETRATION, IF REQUIRED SHALL BE L-19 w % INCLUDED IN ELECTRICAL CONTRACTOR'S BID. ALL OUTLETS, BOXES, CONDUITS, ETC. SHALL BE CONCEALED FROM VIEW. PROVIDE LOCK OFF DEVICE ON CIRCUIT T2(6) BREAKER. SIGNS TO BE CONTROLLED BY TIME CLOCK. LAKE GEORGE 8. ® ®, ® z AMP ® L (29 ® ® ®, ® ® L-26 ® R(D (EXG) 2 AMP F2 L-5VIATCWIRE TO BYPASS SWITCH CONTROL FOR NIGHT LIGHTS, EMERGENCY LIGHTS AND EXIT NY, 12845 ®T2(7) ® ® O 0 ® ® T2(7) ® ® L-5NL LIGHTS. "NL" DENOTES NIGHT LIGHT. T2(2) L-23 ® ® L-24 ® ® \ L-21 3 O3 NON -POWERED TRACK TO BE INSTALLED BY ELECTRICAL CONTRACTOR. SUITE #7 ® 1 STORE #4197 15 ® co ® ® ® z A4P O REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION, LENGTH, r F2 F2� F2 F2 F2 �- F2 °' F2 F2 z AMP QUANTITIES AND MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES WITHIN THE ENTIRE Ti L-71 I ° L-9 Ih4 I I b L-7 �° L-9 � b L-7 ° L-9 b L-7 ° L-9 b L-7 ° O ®LT 17 1 1 6 L1 4 TENANT SPACE. 3 � L-19 X1 Ti VIA TC 0 EXISTING EXHAUST FAN TO REMAIN. SHEET TITLE: wLT 21 ® s L-5 L-15 ® UA(2� O SEE SHEET E4 FOR CURRENT LIMITER SPECIFICATION FOR TRACK LIGHTING. LIGHPLATING 6 ° B A 8 g g ® LT 17 ® T1 07 TIME CLOCK TO BE A 7 DAY, 24 HOUR ELECTROMECHANICAL TORK #W400 OR 6 8 2 o z AMP _ - 8 $ B' 8' L1-4 EQUAL. AMP VIA TC z, i-, p T1 ® ® T7 �® ® T1 ® �® T1 ® ® U T1 ® ® T1 ® T1 ® ® Ti ® ® i1 � Ti 2�_� �; 2 AMP L-15 T2(2) L-15 T2(2) 1' L-15 T2(2) L-15 T2(2) L-15 T2(2) L-15 T2(2) L-15 T2(2) L-15 T2(2) L-15 T2(2) L-15 L1-2REVISIONS: r --- L-17 L-17 L-17 - - - - M L-17 L-17 L-17 L-17 L-17 L-17 6 NO: DATE: BY: j - -1 11.24.2015 LL/BLDG/BASS 12 03 2015 2 LL/BASS JRECEIVED - 3 VERIFY ALL CONITI N%'P% IN FIELDPRIOR TO BIDS. co EXIT AND EMERGENCY LIGHT FIXTURE TYPES AND GENERAL NOTES LOCATIONS ARE SUBJECT TO BUILDING DEPARTMENT • o AND FIRE DEPARTMENT APPROVAL. ri coo PROJECT NO: 3633.0036 LIGHTING PLAN OA SEE ARCHITECTURAL PLANS FOR LIGHT FIXTURE /n ��� REFER TO SHEET E4 FOR GENERAL NOTES FOR POWER. QUANTITIES AND DIMENSIONS 288.16-1-1 CC -000225-2015 DRAWN BY: KO U GH Bass W 0 1424 State Route 9 I. Commerical Alt. Revised plans I a COPYRIGHT PATRICK G. BLEES, AIA 2015 g,ln Q s` r� PATRICK G. BLEES LO - - - -- - _ architecture •planning •interior design L11 GENERAL NOTES ' ' GFC PATRICK G. BLEES ARCHITECT 800 WASHINGTON AVE. N. SUITE 208 C11��MN 55401-1148 PHONE: OLIS, (612) 547-1300 O REFER TO SHEET E4 FOR GENERAL NOTES FOR POWER. FAX: (612) 547-1301 o - -- CONTACT: ANTHONY JOHNSON 'I _ E-MAIL: info@crnarch.com ajohnson®cmarch.com 0 J -- - — - - - ��361 —� ��J' CONSULTANTS: t2\� MECH/PLBG/ELEC EMAN-- __._.__10401UBREONNRD OEASTINC MINNETONKA, MN 55343 El L-10 ❑ (952) 930-0050 � 15 , EXISI - KEYNOTES POWER — J �� _ - k k PiNL L1 0 PNL L' G L-2 L-12 A �I -- IiL ,tern i_ 1O 2'W X 4'H X 3/4" TELEPHONE BOARD MOUNT AT 6'-0" AFF WITH DEDICATED QUADRAPLEX — L-1 0 a it RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL EyQ — OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. EXTEND 1" TELEPHONE CONDUIT L.- ❑2 1$ L-18 WITH PULL -WIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE BOARD. VERIFY 7 L-28 EXACT LOCATION IN FIELD. L-14 p �L-30 �L-32 / \\ O PROVIDE DUPLEX RECEPTACLE FLUSH MOUNTED IN SHOW WINDOW CEILING, RECEPTACLE AND r �r � L—T6 _' L-10 �QQ__Tt��� COVER PLATE COLOR TO BE WHITE. -7f1�L.1T�zLi'�����/ O3 CONTRACTOR SHALL PROVIDE (1) 3/4" CONDUIT W/PULLSTRING AS OUTLINED BELOW: SEAL: --A� L-4 (1) 3/47CONDUIT FOR POWER: IJ L4M� rz�r �4 NOT USED. L. C_ LOW BE W _ o LWW {U) _ & 1#10 G PUSHBUTTON DOORBELL. O FIELD OV VERIFY EXACTSLOCATIION.R USE WITH REAR SERVICE DOOR ��%a`�� - i -I - 1 s ; L-8 C O RTU WP E4J 0 C , �2 c i O6 WIRE -MOLD SURFACE RACEWAY BY TENANT'S GENERAL CONTRACTOR. SEE DETAIL ON?L- ARCHITECTURAL DETAIL SHEET. PLUG INTO DUPLEX RECEPTACLE MOUNTED BELOW COUNTER. ��,� aai3a�, II I � SEE ARCHITECTURAL DETAIL FOR EXACT LOCATION AND MOUNTING HEIGHTS FOR DEVICES IN THIS L AREA. L L -4 I-- L-@ SO NOT USED. L �- 20 LiSF1,3,5 / o TO EXTOR BENEATH ONE IT IS A VIOLATION OF THE LAW FOR ANY CASH-ENPTOSBACK WRAP THROUGHN ON TARSECOND SALL CONDUITS TO EXIT AT A SINGLE TRENCH IINGLEL PLANS. ERE NEEDED, ALL TR TRENG IN THE NCH ENINGNNCTHEAFLOORNASITS WAYOUNLESSALTER ACTING ITEM UNDER THE — -- -- - SHOWN ON ARCHITECTURAL PLANS. DIRECTION OF A LICENSED ENGINEER. o RECEPTACLES AND TELEPHONE JACKS TO BE MOUNTED INSIDE CASH -WRAP AT LOCATION SHOWN F_ - ON ARCHITECTURAL PIANS. MATTHEW W. FULTS - - — - 1 PROVIDE NEW LOW VOLTAGE PUSH-BUTTON FOR SERVICE DOOR MOUNTED AT 54" AFF MAX. SIGNATURE PUSH-BUTTONOR SYSTEM WIRING. IN STOCKROOM AND BUZZER AT CASHWRAP AREA. SEE 10-09-2015 SHEET E li DATE ISSUED - ___ L _ 12 PROVIDE CONNECTION TO 120 VOLT SINGLE PHASE, 1.5 KW WATER HEATER. PROVIDE 1/2" 087346-1 ry� f El ELECTRICAL CONDUIT WITH 2#12 CU. TO PANEL. WATER HEATER PROVIDE BY MECHANICAL CONTRACTOR. REG. N0. ELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION. FIELD VERIFY LOCATION PRIOR TO -- ----------- --- INSTALLATION. 73 EXISTING RTU -1: 208V/3PH EXISTING HVAC UNIT AND ALL ASSOCIATED COMPONENTS, f L-20 � O DISCONNECT SWITCH, DUCT DETECTORS, ROOF TOP RECEPTACLE AND ETC. ARE EXISTING TO / 1 o L -22o O � I ❑i REMAIN. GH.Ba'v'%' g L-8 EXISTING DUCT SMOKE DETECTOR TO REMAIN. COORDINATE ALL REQUIREMENTS WITH LANDLORD. L-20':1 o O IGT' O2 �c ! 14 VERIFY DUCT DETECTOR EXISTS PRIOR TO BID. PROVIDE NEW IF REQUIRED. 10 l — - L 31,33,35 L-22 • 1' Q -3t6 E' t5 ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL REMOTE TEST SWITCH WITH VISUAL/AUDIBLE & #1 G- L INDICATION AT MANAGER'S DESK. TEST SWITCH TO BE AIR PRODUCTS AND CONTROLS INC. t 3 cFCi RTU wP �. CATALOG NUMBER MSR-100R/R OR EQUAL. COORDINATE ALL REQUIREMENT WITH LANDLORD. OUTLETS AT -- L-34 — r_ o L-20,� o IILL F � LAKE GEORGE 14 a 16 RTU -2: 208/3HP: ELECTRICAL CONTRACTOR TO MAKE CONNECTION TO FUSED DISCONNECT SWITCH AT UNIT, DUCT SMOKE DETECTOR IN RETURN DUCT AND CONVENIENCE WEATHERPROOF RECEPTACLE AT UNIT 1424 STATE RT 9 L Li -7,9,1 / 17 PROVIDE LOW VOLTAGE BUZZER TO BE MOUNTED AT 8'-0" FOR USE WITH REAR SERVICE DOOR 21 SF__.. PUSHBUTTON DOORBELL. LOCATE NEAR ELECTRICAL PANELS. F- 2 \ 1a PROVIDE LOW VOLTAGE TRANSFORMER ON WALL AT 8'-0" AFF. TRANSFORMER OPERATES LAKE GEORGE BUZZERS) FOR REAR DOORBELL PUSHBUTTON, LOCATE NEAR ELECTRICAL PANELS. SEE SHEET N Y , 12845 E3 FOR SYSTEM WIRING. i9 DUCT SMOKE DETECTOR PROVIDE IN RETURN AIR DUCT TO SHUT DOWN FAN, DUCT DETECTOR SUITE 7 BY ROOF TOP UNIT SUPPLIER. COORDINATE ALL REQUIREMENT WITH LANDLORD, C L L-6 L-6 20 PROVIDE CONNECTION TO 208 VOLT THREE PHASE, 6.6 AMP SUPPLY FAN (SF -1). PROVIDE STORE #4197 F- F % - O 1/7' CONDUIT WITH 3#12 CU. TO PANEL. SF -1 PROVIDE BY MECHANICAL CONTRACTOR. - IELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION. FIELD VERIFY LOCATION PRIOR TO L-8 INSTALLATION. zt PROVIDE CONNECTION TO 206 VOLT THREE PHASE, 6.6 AMP SUPPLY FAN (SF -2). PROVIDE f 011SHEET TITLE: 11 i 1/7' CONDUIT WITH 3#12 CU. TO PANEL. SF -2 PROVIDE BY MECHANICAL CONTRACTOR. POWER o L L - ELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION. FIELD VERIFY LOCATION PRIOR TO PLAN INSTALLATION. w L=6 REVISIONS: _ L -g -- -- ---- --- L-6 r� NO: DATE: BY: LL/BLDG/BASS 12.03.2015 LL/BASS z L rn 0 0 Y 1 POWER PLAN a I N N D VERIFY ALL CONDITIONS IN FIELD I T IDS. o PROJECT N0: 3633.0036 M DRAWN BY: KO M cn E 2u% cD M H O 0_ COPYRIGHT PATRICK G. BLEES, AIA 2015 d ELECTRICAL SYMBOLS THESE SYMBOLS COMPRISE A STANDARD LIST; ALL SYMBOLS MAY NOT APPEAR ON THIS PROJECT. SYMBOL DESCRIPTION MTG HT A=- 3 a LIGHT FIXTURE INDICATING FIXTURE TYPE, CIRCUIT NUMBER AND SWITCHING ®. FLUORESCENT FIXTURE RECESSED MOUNTED CEILING EZIFLUORESCENT FIXTURE SURFACE MOUNTED CEILING �—( STRIP. TYPE FIXTURE CEILING 19 EXIT LIGHT FACE/DIRECT ARROWS AS INDICATED _ EXIT LIGHT FACE W/ EMERGENCY HEADS BURGLAR ALARM PANEL rqqq FIXTURE ON EMERGENCY CIRCUIT O EMERGENCY LIGHTING UNIT ® $ SINGLE POLE SWITCH - LETTER INDICATES SWITCHING 46" $ $3 $4 - DOUBLE POLE, 3 -WAY AND 4 -WAY 46' 0 DIMMER WITH TYPE AS INDICATED © LIGHTING CONTACTOR O ® Q TIME CLOCK EMERGENCY PHONE qP SM DEDICATED DUPLEX (SINGLE CIRCUIT) FOR SENSORMATION M DEDICATED DUPLEX FOR MUSIC MTD® 5'-0" A.F.F. qP D DEDICATED DUPLEX 24V �WP SS CP IG DUPLEX WP INDICATES WEATHERPROOF IN -USE COVER SS INDICATES STAINLESS STEEL FACEPLATE CP INDICATES CHILDPROOF RECEPTACLE IG INDICATES ISOLATED GROUND 1B" Tf FOURPLEX 18" �. GFCI. 18" 0 CEILING MOUNT JUNCTION BOX - CEILING - CEILING Q �F JUNCTION BOX - WALL 8O O FLOOR FLOOR 3 4 METER 2'-0' .__ PANEL SURFACE (BRANCH) PANEL FLUSH (BRANCH) iflY TOGGLE SWITCH - MOTOR RATED XX MOTOR WITH ELECTRICAL CONNECTION; REFER TO MOTOR SCHEDULE ❑P DISCONNECT 4'-0"A.F.F. ® ALARM KEYPAD - MTD. ABOVE SWITCH BANK DIGITAL DCOR MAX SENSORMATIC SEE DETAIL 2 SHEET A-2,0 u LOW VOLTAGE BUZZER 'Q TRANSFORMER FOR LOW VOLTAGE BUZZER LOW VOLTAGE PUSHBUTTON - WALL MOUNTED FIRE ALARM STROBE 90' FIRE ALARM HORN/STROBE 90' ® FIRE ALARM CEILING STROBE CEILING FIRE ALARM CEILING HORN/STROBE CEILING �- FIRE/SMOKE DAMPER THE LOW VOLTAGE TRANSFORMER OPERATES THE BUZZER(S). (D FIRE ALARM SMOKE DETECTOR - PHOTOELECTRIC CEILING O1 A -PHONE 2 DMX 3 JUNCTION BOX WITH COVERPLATE FOR SPEAKER WIRE ® DUPLEX REG. FOR DMX 5 FOUR PLEX REC. 66 JUNCTION BOX WITH COVERPLATE FOR ETHERNET CABLE O DUPLEX REC. FOR REFRIGERATOR ALL DIMENSIONS OFF EDGE OF STORAGE SHELVING UPRIGHT. ELECTRICAL CONTRACTOR TO VERIFY LOCATION OF STORAGE SHELVING UPRIGHT WITH TENANT'S SUPERINTENDENT ELEVATION @ MANAGER AND EMPLOYEE DESKS SCALE: NONE TENANT'S SECURITY CONTRACTOR (CHECKPOINT) TO PROVIDE AND INSTALL MOTION DETECTION SYSTEM AT SWING DOOR. NOT USED �r t PATRICK BLEES architecture • planning < interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info®cmarch.com CONTACT:ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: y A`�'9ia��z, 5 '2i✓' a s+l" W 3 "4 <FR 1, os a, .yiy fro*C?rgUr�' �v'�t�+�'+'� _,"+�•n�'L( IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MATTHEW W. FULTS SIGNATURE - ---- -- 10-09-2015 DATE ISSUED 087346_ -1 REG_N0.. G 11 &-m BU&-% sb • • • OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: ELECTRICAL DETAILS REVISIONS: NO: DATE: BY: 'ROJECT N0: 3633.0036 IRAWN BY. KO E 3 OPYRIGHT PATRICK G. BLEES, AIA 2015 1❑ PUSH-BUTTON AT EXTERIOR ❑3 STOCKROOM BUZZER. COMMUNICATION RACK OF REAR SERVICE DOOR. 120V. O 2 DED. REC FOR PHONE ROUTER TRANSFORMER L N ® CASHWRAP BUZZER. ®OO 3 BURGLAR ALARM PANEL O ® DED. REC FOR BURGLAR ALARM 0 T1 SMART JACK O ® O © EMERGENCY PHONE o ®i 24V D ALARM RJ31X JACK 2 Q �F 8O 66 BLOCK 1 3 4 2'-0' 2'-0' Q COLOR WIRING DIAGRAM 4'X6' PLY WD 4'-0"A.F.F. THE PUSHBUTTON AT EXTERIOR OF SERVICE DOOR ACTIVATES BUZZER IN STOCKROOM AND BUZZER AT CASHWRAP AREA. THE LOW VOLTAGE TRANSFORMER OPERATES THE BUZZER(S). 3 ELEVATION @ PHONE ROUTER SECURITY SYSTEM TDOOR ANNUNCIATOR SYSTEM DIAGRAM E3 SCALE: NONE SCALE: NONE NOT USED �r t PATRICK BLEES architecture • planning < interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E—MAIL: info®cmarch.com CONTACT:ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: y A`�'9ia��z, 5 '2i✓' a s+l" W 3 "4 <FR 1, os a, .yiy fro*C?rgUr�' �v'�t�+�'+'� _,"+�•n�'L( IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MATTHEW W. FULTS SIGNATURE - ---- -- 10-09-2015 DATE ISSUED 087346_ -1 REG_N0.. G 11 &-m BU&-% sb • • • OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: ELECTRICAL DETAILS REVISIONS: NO: DATE: BY: 'ROJECT N0: 3633.0036 IRAWN BY. KO E 3 OPYRIGHT PATRICK G. BLEES, AIA 2015 LIGHTING FIXTURE LEGEND PANEL: EXIST L1 LOCATION: STOCKROOM VOLTS: 208 / 120 PH: 3 W: 4 AMP MAIN BRKR: 100 AMP MLO: SCCR: 10,000 MOUNT: SURFACE FED FROM: LL CIRCUIT DESCRIPTION PANELSCHEDULE VOLTAGE LAMP INPUT SYMBOL TYPE DESCRIPTION LOAD VA TYPE WATTS 792 A INDUSTRIAL (2) LAMP FIXTURE W/ CHAIN HANGER KIT 10,000 T8 LAMP MOUNT: SURFACE FED FROM: LL 0 720 STOREFRONT LIGHTS NOTE 1/2 OPTIONAL WIRE GUARD & ROW ALIGNERS 4' strip UNV (2) F028/830/XP/SS/ECO 52 4 A -NL DAY-BRITE T-232T8-UNV LOAD STOREFRONT LIGHTS NOTE 1/2 CIRCUIT DESCRIPTION 792 - Al INDUSTRIAL (4) LAMP TAMDEN FIXTURE W/ CHAIN HANGER KIT PH T8 LAMP 500 0 - - Al -NL OPTIONAL WIRE GUARD & ROW ALIGNERS 8' STRIP TAMDEN DAY-BRITE TT-432T8-UNV UNV (4) F028/830/XP/SS/ECO 107 BKR 4 B PHILUP'S FORECAST: F9079519NV 792 60 WATT 3 9 10 STOREFRONT SIGN SCONCE FIXTURE - OCEAN VIEW - BLACK 120 INCANDESCENT 60 1 1 A B C A B C A B C A B C A B C A B C A B C UGHTOUER: 1102P1 - 1113 1 20 860 4 D -LED RECESSED CEILING FIXTURE - 6 3/4" APERATURE PAR38 RECESSED DOWNLIGHT CLEAR 20 LED17P383OKFL 17 1 20 REFLECTOR, WHITE TRIM RING, HANGER BARS INCLUDED, 17 W LED PAR 38 40' FLOOD 120 EXIT/EMERGENCY LIGHTS NOTE 2 802 20 1 5 LA LIGHTING: LCD 847-2-2RU6-W9-2E81-UNV 1 GE 900 SALES RECEPTS F-2 2'X2' 9 CELL PARABOLIC FLUORESCENT, STEEL CABLE HUNG, WHITE ALUMINUM LOUVER, (1) 2 20 (2) F32T8/SP30/U/6 56 1 20 LAMP ELECTRONIC BALLAST. SHOW WINDOW SALES LIGHTS NOTE 2 1008 20 SUSPEND AT 11'4" AFF TO BASE OF FIXTURE. GC TO SUPPLY CABLE. ADJUST LOCATION DUE 10 1 20 900 STOCK RECEPTS F2 -NL TO SITE CONDITIONS/OBSTRUCTIONS. UNV 1 11 12 1 X 180 ALARM NOTE 2 TRACK LIGHTS NOTE 2 1080 20 LED PHILIPS CHLORIDE VERWEM -EXIT SIGN WITH BATTERY BACK-UP, MOUNT ABOVE 12'-6" 1 20 500 ® EXIT AFF IN STOCKROOM AND 11'-4" AFF OTHERWISE OR PER AHJ, UNV LED - 2.5W/FACE 5 1 LIGHT 180 DESK RECEPTS VOLTAGE: 120V 720 20 (EXG) EXISTING TO REMAIN - - - COMPUTER RECEPTS NOTE 2 (RELO) EXISTING FIXTURE TO BE RELOCATED, 20 1 19 20 1 X1 CEILING OR WALL MT EMERGENCY LIGHT POLYCARBONATE CASH REGISTER NOTE 2 TRACK LIGHTS NOTE 2 360 20 1 21 HOUSING WI/ SELF-CONTAINED POWER PACK FOR 90 MIN. 1 20 720 COUNTER RECEPTS NOTE 2 LED OPERATION. WHITE HOUSING. TGC TO PROVIDE EXITRONIX: 20 LED 24 1 EMERG. LED -90 N= NEW EX -REL = RELOCATE EXISTING (SEE RCP UNV PURCHASE & INSTALL. - 20 LIGHT DEMO) T.G.0 TO INSTALL EMERG. LIGHT AS CLOSE TO 1 BY TGC. 1080 TRACK LIGHTS NOTE 2 STOCK/RR LIGHTS NOTE 2 CEILING AS POSSIBLE WITHIN CODE 20 1 27 28 1 X2 500 CONTACTOR/TC/BUZZER NOTE 2 TRACK LIGHTS NOTE 2 960 20 EMERG. LIGHT/EXIT PHILIPS CHLORIDE VCRWLRC -LED EXIT SIGN AND 5.4W TUNGSTEN HALOGEN EMERGENCY LIGHT COMBINED UNIT WITH BATTERY BACK-UP, MOUNT ABOVE 12'-6" UNV INCLUDED 6 REFRIGERATOR COMBO AFF IN STOCKROOM AND 11'-4" AFF OTHERWISE OR PER AHJ, - - 31 32 1 (RELO) EXISTING FIXTURE TO BE RELOCATED. RECEPTACLES NOTE 2 EXIST RTU -1 NOTE 2 4812 50 (EXG) EXISTING TO REMAIN 1 - 360 RTU RECEPTACLE - 4812 - CM H70TU/830/G 12 Volts KVA Amps Aw4 Ft. Amps Cu LIGHTING 1.44 KVA 1.80 LARGEST MOTOR 2.38 KVA 2.97 KVA (125%) MOTORS 2.38 KVA 2.38 KVA (100%) RECEPT 0.00 KVA 0.00 KVA(10KVA®100%,REMAIN050%) KITCHEN EQUIPMENT 0.00 KVA 0.00 KVA (65%) ELECTRONIC LOADS 0.00 KVA 0.00 KVA (100%) ELECTRIC HEATING 0.00 KVA 0.00 KVA (100%) MISC. 0.50 KVA 0.50 KVA (100%) " '€, _' a ;+.' ;+` .. ; LIGHTOLIER: 81 F 70T6WH GE 3360 - T1 -WH LYTESPAN TRACK FIXTURE- METAL HALIDE WALL WASH - T6 -70W CERAMIC METAL HALIDE 120 - 80 - - RIU-2 NOTE 2 3360 UGHTOLIER: 9038NWH 3 39 40 3 ® T2 -LED LYTESPAN LITESPAN TRACK FIXTURE - 17W LED PAR 38 WITH 40' FLOOD 120 LED17P3830KFL 17 - 41 SINGLE LIGHTOLIER LYTESPAN TRACK (WHITE) WITH MOUNTS R 4'-O' O.C. LENGTHS TO NEAREST FOOT a, "' ` r ro RCUIT TRACK AS REQUIRED. SURFACE MOUNT TO UNDERSIDE OF SOFFIT/FACE OF BULKHEAD AT NOTES: 1. VIA TIME CLOCK 2. PROVIDE LOCK ON DEVICE 3. 4. 5, Prim 'Vdrop = 0.78 Volts CURRENT CALCULATIONS: Prim Vdrop% Isc (Xfmr Secondary) - Amps Sec Vdrop = NA Volts Isc (At Panel) = 5055 Amps Sec Vdrop% _ Isc (w/ motor conlrib:) = 5121 Amps (y ` ,;" - .1 STOREFRONT, SUSPEND 0 11'-8" AFF WITH UNISTRUT & THREADED ROD FROM STRUCTURE 120 EFL ABOVE THROUGHOUT SALES. PAINT ROD, HARDWARE AND UNISTRUT 4'-6004NWH LOAD SUMMARY: CONNECTED FEEDER / SERVICE CALCULATION VI -I Primary: 8'-6008NWH 208 Volts VI -I Secondary: Volts LIGHTING 15.72 KVA 19.65 KVA 1257 !,.., TWO LIGHTOLIER LYTESPAN TRACK (WHITE) WITH MOUNTS ® 4'-0" O.C. LENGTHS TO NEAREST FOOT 21.02 KVA (125%),,. CIRCUIT TRACK AS REQUIRED. SURFACE MOUNT TO UNDERSIDE OF SOFFIT/FACE OF BULKHEAD AT STOREFRONT. SUSPEND 0 11'-8" AFF WITH UNISTRUT & THREADED ROD FROM STRUCTURE 120 - - ( Motor (FLA): ABOVE THROUGHOUT SALES. PAINT ROD, HARDWARE AND UNISTRUT 4'-6104NWH Transformer Z%: RECEPT 7.16 KVA 7,16 KVA(10KVA0100%,REMAIN#50%) :: `Z W-6108NWH, 6112NWH 42000 Amps Avail. Fault (lafc): Amps KITCHEN EQUIPMENT 0.00 KVA HI -LITE MFG. CO.: H-15116-93 / 30" ST -HSC -93/42 z " Feeder Size: 3 0 Awg Q. Feeder Size: Awg. OAH/GL-PAN-FR 0.00 KVA 0.00 KVA (100%) `a " Feeder Length P WAREHOUSE COLLECTION SHADE. WHITE, 30" WHITE STEM MEDIUM BASE 120 EL/MDT2 13W 13 KVA 100% 0.00 ( ) SOCKET. MOUNTED 0 ST A.F.F. TO BOTTOM OF FIXTURE. GO TO USE (1) (41399-6) Parallel Sets: MISC. 4.00 KVA 12" LENGTH & (1) 18" LENGTH STEM TO INSTALL PENDANT te, Power Factor % 90% Power Factor % POWER TRIP MODULES Feeder/Load Amps: 'C' Value: PLD 120WH 1 AMP Amps Feeder/Load Amps: Amps Cu 'C' Value: Cu TOTALS 56 KVA 64 KVA HI -PHASE 156 AMPS PT PLD 240WH 2 AMP Nolt Drop' Value: 151 6099 PLD 360WH 3 AMP WH PLD 480WH 4 AMP PLD 600WH 5 AMP �.:, ., .�... a.i u, £ .R mgt ," sf�.., Y._ •tY"+Y kr 'd` i'Y%S'. PLD 720WH 6 AMP - PLD 840WH 7 AMP ACCOCATIUN : PLD 960WH 8 AMP CONNECTED LOAD PLD 1320WH 11 AMP RMS BOLTED 3 PHASE SHORT CIRCUIT 1, VIA TIME CLOCK PLD 1440WH 12 AMP a1s m-_ PER PHASE 1'k Prim 'Vdrop = 6.04 * REFER TO POWER TRIP NOTE 2, PROVIDE LOCK ON DEVICE + (EXG) EXISTING TO REMAIN 120 POWER TRIP NOTE: I M PT 6099 WH THE BUSWAY LIGHTING SYSTEM USES A CURRENT LIMITING DEVICE "POWER TRIP" MOUNTED AT THE POWER FEED POINT ON EACH BUSWAY RUN, "POWER TRIP"CONNECTORS CONTAIN A MINIATURE ELECTROMAGNETIC CIRCUIT BREAKER THAT LIMITS THE CURRENT LOAD ON THE BUSWAY TO A SPECIFIED AMPERAGENVATTAGE. EXCEEDING THE SPECIFIED AMPERAGE/WATTAGE RATING OFTHE "POWER TRIP" DEVICE, BREAKS THE CIRCUIT AND SHUTS OFF POWER TO THE BUSWAY. THE BUSWAY ENERGY LOAD IS LIMITED TO THE MAXIMUM SPECIFIED AMPERAGENVATTAGE OF THE PARTICULAR "POWER TRIP" DEVICE USED. NOTE THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR THE EXACT DIMENSIONAL LAYOUT OF THE LIGHTS AND TO CONFIRM QUANTITIES. LAMPS ARE TO BE PROVIDED BY TENANT AND INSTALLED BY G.C. ON ALL LIGHT FIXTURES ABSOLUTELY NO FLEXIBLE CONDUIT IS PERMITTED IN DEMISING WALLS. FLEXIBLE CONDUIT IS PERMITTED FOR SHORT FINAL CONNECTIONS ONLY (6'-0" OR LESS). EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES, PARALLEL OR IN RIGHT ANGLES TO THE BUILDING STRUCTURE. DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE OR WALL CAVITY. CABLE TYPES AC AND NM CABLES ARE NOT ACCEPTABLE. TYPE MC CABLE, ELECTRIC METALLIC TUBING (EMT) AND RIGID GALVANIZED CONDUIT ARE PERMITTED. ALL EQUIPMENT, DEVICES AND FIXTURES SHALL BE GROUNDED IN COMPLIANCE WITH NEC AND UL REQUIREMENTS. ALL PANELS TO BE UL LISTED WITH BOLT ON TYPE CIRCUIT BREAKER. 7 -DAY, 24-HOUR TIME CLOCK IS REQUIRED TO CONTROL STOREFRONT LIGHTS, SHOW WINDOW RECEPTACLES AND STOREFRONT SIGN. ILLUMINATED STOREFRONT SIGNS MUST REMAIN LIT DURING ALL MALL BUSINESS HOURS. ALL ELECTRICAL PANELS TO BE MOUNTED ON PLYWOOD BACKER BOARD PANEL PHASE LOADS TO BE BALANCED WITHIN 10%. TENANT IS REQUIRED TO MAKE FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED THE ELECTRICAL SERVICE. ANY/ALL MODIFICATIONS OR UPGRADES NEEDED ARE SUBJECT TO LANDLORD'S PRIOR APPROVAL, AND WILL BE COMPLETED BY TENANT/TENANT'S GENERAL CONTRACTOR AT TENANT'S SOLE EXPENSE. ELECTRICAL PANELS MAY NOT BE RECESSED IN DEMISED PARTITIONS. ONLY 30KVA AND SMALLER TRANSFORMERS MAY BE SUSPENDED FROM BUILDING STRUCTURE. ALL OTHER TRANSFORMERS MUST BE FLOOR SUPPORTED. FLOOR PENETRATIONS, TENANT'S GENERAL CONTRACTOR MUST ADVISE THE PROPERTY'S OPERATION DIRECTOR PRIOR TO ANY SLAB CUTTING OR REMOVAL. ALL FLOOR PENETRATIONS MUST BE CORE -BORED OR SAW -CUT (NO JACK -HAMMERING IS PERMITTED). PRIOR TO WORK, TENANT'S GENERAL CONTRACTOR MUST VERIFY THAT TENANT'S WORK WILL NOT CONFLICT WITH EXISTING STRUCTURAL UTILITY OR OTHER UNDER -SLAB CONDITIONS. TENANT'S WORK MUST NOT COMPROMISE OR DAMAGE THE EXISTING STRUCTURE. ANY DAMAGE CAUSED BY TENANT'S WORK IS TO BE REPAIRED AT TENANTS EXPENSE. TENANT'S ELECTRICAL CONTRACTOR INSTALL 2"C-4#3/0 & 1#6 GND. DISTRIBUTION CENTER TO TENANT'S COORDINATE ROUTING AND DISTANC PRIOR TO INSTALLATION. EXISTING LANDLORD 120/208 V 3 PHASE 4 WIRE DISTRIBUTION EXISTING METER AND METER SOCKET TO REPORT ANY DIFFERENCE TO OWNER'S REPRESENTATIVE PRIOR TO BIDDING, TENANT'S ELECTRICAL CONTRACTOR TO FI AND INSTALL NEW 200A/3P CIRCUIT BRE COORDINATE ALL REQUIREMENT WITH LANI MATCH EXISTING. 0 PANEL SCHEDULE PANEL: EXIST L1 LOCATION: STOCKROOM VOLTS: 208 / 120 PH: 3 W: 4 AMP MAIN BRKR: 100 AMP MLO: SCCR: 10,000 MOUNT: SURFACE FED FROM: LL CIRCUIT DESCRIPTION PANELSCHEDULE CKT BKR ❑ CIR P # PANEL: L LOCATION: STOCKROOM VOLTS: 208 / 120 LOAD VA PH: 3 W: 4 AMP MAIN BRKR: 200 792 AMP MLO: SCCR: 10,000 2 MOUNT: SURFACE FED FROM: LL 20 720 STOREFRONT LIGHTS NOTE 1/2 LOAD 792 C# IR 3 3 4 CKT LOAD STOREFRONT LIGHTS NOTE 1/2 CIRCUIT DESCRIPTION 792 - - 5 6 PH 20 500 EWC NOTE 2 - - CIRCUIT DESCRIPTION - 7 8 1 BKR SPARE #R 792 BKR 3 9 10 STOREFRONT SIGN NOTE 1/2 1200 20 1 1 A B C A B C A B C A B C A B C A B C A B C 2 1 20 860 ThB NOTE 2 STOREFRONT SIGN NOTE 1/2 1200 20 1 3 4 1 20 900 SALES RECEPTS EXIT/EMERGENCY LIGHTS NOTE 2 802 20 1 5 6 1 20 900 SALES RECEPTS SALES LIGHTS NOTE 2 1008 20 1 7 8 1 20 540 SHOW WINDOW SALES LIGHTS NOTE 2 1008 20 1 9 10 1 20 900 STOCK RECEPTS TRACK LIGHTS NOTE 2 720 20 1 11 12 1 20 180 ALARM NOTE 2 TRACK LIGHTS NOTE 2 1080 20 1 '13 14 1 20 500 MUSIC SYSTEM TRACK LIGHTS NOTE 2 1080 2D 1 15 16 1 20 180 DESK RECEPTS TRACK LIGHTS NOTE 2 720 20 1 17 18 1 20 720 COMPUTER RECEPTS NOTE 2 TRACK LIGHTS NOTE 2 480 20 1 19 20 1 20 540 CASH REGISTER NOTE 2 TRACK LIGHTS NOTE 2 360 20 1 21 22 1 20 720 COUNTER RECEPTS NOTE 2 TRACK LIGHTS NOTE 2 720 20 1 23 24 1 20 720 TRACK LIGHTS NOTE 2 CASHWRAP NOTE 2 340 20 1 25 26 1 20 1080 TRACK LIGHTS NOTE 2 STOCK/RR LIGHTS NOTE 2 1000 20 1 27 28 1 20 500 CONTACTOR/TC/BUZZER NOTE 2 TRACK LIGHTS NOTE 2 960 20 1 29 30 1 20 1000 REFRIGERATOR - 4812 - - 31 32 1 20 360 RECEPTACLES NOTE 2 EXIST RTU -1 NOTE 2 4812 50 3 33 34 1 20 360 RTU RECEPTACLE - 4812 - - 35 Volts KVA Amps Aw4 Ft. Amps Cu LIGHTING 1.44 KVA 1.80 LARGEST MOTOR 2.38 KVA 2.97 KVA (125%) MOTORS 2.38 KVA 2.38 KVA (100%) RECEPT 0.00 KVA 0.00 KVA(10KVA®100%,REMAIN050%) KITCHEN EQUIPMENT 0.00 KVA 0.00 KVA (65%) ELECTRONIC LOADS 0.00 KVA 0.00 KVA (100%) ELECTRIC HEATING 0.00 KVA 0.00 KVA (100%) MISC. 0.50 KVA 0.50 KVA (100%) " '€, _' a ;+.' ;+` .. ; 208 - - 3360 - - 37 38 - - 2304 - - RIU-2 NOTE 2 3360 40 3 39 40 3 100 2304 EXIST PANEL L1 NOTE 2 3360 - 41 42 a, "' ` r ro NOTES: 1. VIA TIME CLOCK 2. PROVIDE LOCK ON DEVICE 3. 4. 5, Prim 'Vdrop = 0.78 Volts CURRENT CALCULATIONS: Prim Vdrop% Isc (Xfmr Secondary) - Amps Sec Vdrop = NA Volts Isc (At Panel) = 5055 Amps Sec Vdrop% _ Isc (w/ motor conlrib:) = 5121 Amps (y ` ,;" - .1 PER PHASE A: 2 KVA B: 2 KVA C: 2 KVA EFL EVERINFU VA I A: LOAD SUMMARY: CONNECTED FEEDER / SERVICE CALCULATION VI -I Primary: 208 Volts VI -I Secondary: Volts LIGHTING 15.72 KVA 19.65 KVA 1257 !,.., LARGEST MOTOR 16.81 KVA 21.02 KVA (125%),,. ;;;,`>, Transformer KVA: KVA MOTORS 12.66 KVA 12.66 KVA (1007) ( Motor (FLA): 82& Transformer Z%: RECEPT 7.16 KVA 7,16 KVA(10KVA0100%,REMAIN#50%) :: `Z Avail. Fault (Iafc): 42000 Amps Avail. Fault (lafc): Amps KITCHEN EQUIPMENT 0.00 KVA 0.00 KVA (65%) " Feeder Size: 3 0 Awg Q. Feeder Size: Awg. ELECTRONIC LOADS 0.00 KVA 0.00 KVA (100%) `a " Feeder Length (L): 200 Ft. 1 Feeder Length (L): Ft. ELECTRIC HEATING 0.00 KVA KVA 100% 0.00 ( ) Parallel Sets: 1 Parallel Sets: MISC. 4.00 KVA 4.00 KVA (100%) te, Power Factor % 90% Power Factor % Feeder/Load Amps: 'C' Value: 200 13923 Amps Feeder/Load Amps: Amps Cu 'C' Value: Cu TOTALS 56 KVA 64 KVA HI -PHASE 156 AMPS 179 AMPS 181 A Nolt Drop' Value: 151 'Volt Drop' Value: �.:, ., .�... a.i u, £ .R mgt ," sf�.., Y._ •tY"+Y kr 'd` i'Y%S'. ACCOCATIUN : NOTES: CONNECTED LOAD RMS BOLTED 3 PHASE SHORT CIRCUIT 1, VIA TIME CLOCK a1s m-_ PER PHASE 1'k Prim 'Vdrop = 6.04 Volts CURRENT CALCULATIONS: 2, PROVIDE LOCK ON DEVICE + A: 18 KVA .J Prim Vdrop% 3, 4, T '' B: 19 KVA_ C: 19 KVA Sec Vdrop = NA Isc (Xfmr Secondary)= Amps Volts Isc (At Panel) = 6972 Amps 5, a > Sec Vdrop% = Isc (w/ motor contrib.) = 738E Amps �z ABSOLUTELY NO FLEXIBLE CONDUIT IS PERMITTED IN DEMISING WALLS. FLEXIBLE CONDUIT IS PERMITTED FOR SHORT FINAL CONNECTIONS ONLY (6'-0" OR LESS). EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES, PARALLEL OR IN RIGHT ANGLES TO THE BUILDING STRUCTURE. DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE OR WALL CAVITY. CABLE TYPES AC AND NM CABLES ARE NOT ACCEPTABLE. TYPE MC CABLE, ELECTRIC METALLIC TUBING (EMT) AND RIGID GALVANIZED CONDUIT ARE PERMITTED. ALL EQUIPMENT, DEVICES AND FIXTURES SHALL BE GROUNDED IN COMPLIANCE WITH NEC AND UL REQUIREMENTS. ALL PANELS TO BE UL LISTED WITH BOLT ON TYPE CIRCUIT BREAKER. 7 -DAY, 24-HOUR TIME CLOCK IS REQUIRED TO CONTROL STOREFRONT LIGHTS, SHOW WINDOW RECEPTACLES AND STOREFRONT SIGN. ILLUMINATED STOREFRONT SIGNS MUST REMAIN LIT DURING ALL MALL BUSINESS HOURS. ALL ELECTRICAL PANELS TO BE MOUNTED ON PLYWOOD BACKER BOARD PANEL PHASE LOADS TO BE BALANCED WITHIN 10%. TENANT IS REQUIRED TO MAKE FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NOT EXCEED THE ELECTRICAL SERVICE. ANY/ALL MODIFICATIONS OR UPGRADES NEEDED ARE SUBJECT TO LANDLORD'S PRIOR APPROVAL, AND WILL BE COMPLETED BY TENANT/TENANT'S GENERAL CONTRACTOR AT TENANT'S SOLE EXPENSE. ELECTRICAL PANELS MAY NOT BE RECESSED IN DEMISED PARTITIONS. ONLY 30KVA AND SMALLER TRANSFORMERS MAY BE SUSPENDED FROM BUILDING STRUCTURE. ALL OTHER TRANSFORMERS MUST BE FLOOR SUPPORTED. FLOOR PENETRATIONS, TENANT'S GENERAL CONTRACTOR MUST ADVISE THE PROPERTY'S OPERATION DIRECTOR PRIOR TO ANY SLAB CUTTING OR REMOVAL. ALL FLOOR PENETRATIONS MUST BE CORE -BORED OR SAW -CUT (NO JACK -HAMMERING IS PERMITTED). PRIOR TO WORK, TENANT'S GENERAL CONTRACTOR MUST VERIFY THAT TENANT'S WORK WILL NOT CONFLICT WITH EXISTING STRUCTURAL UTILITY OR OTHER UNDER -SLAB CONDITIONS. TENANT'S WORK MUST NOT COMPROMISE OR DAMAGE THE EXISTING STRUCTURE. ANY DAMAGE CAUSED BY TENANT'S WORK IS TO BE REPAIRED AT TENANTS EXPENSE. TENANT'S ELECTRICAL CONTRACTOR INSTALL 2"C-4#3/0 & 1#6 GND. DISTRIBUTION CENTER TO TENANT'S COORDINATE ROUTING AND DISTANC PRIOR TO INSTALLATION. EXISTING LANDLORD 120/208 V 3 PHASE 4 WIRE DISTRIBUTION EXISTING METER AND METER SOCKET TO REPORT ANY DIFFERENCE TO OWNER'S REPRESENTATIVE PRIOR TO BIDDING, TENANT'S ELECTRICAL CONTRACTOR TO FI AND INSTALL NEW 200A/3P CIRCUIT BRE COORDINATE ALL REQUIREMENT WITH LANI MATCH EXISTING. 0 PANEL SCHEDULE PANEL: EXIST L1 LOCATION: STOCKROOM VOLTS: 208 / 120 PH: 3 W: 4 AMP MAIN BRKR: 100 AMP MLO: SCCR: 10,000 MOUNT: SURFACE FED FROM: LL CIRCUIT DESCRIPTION LOAD VA CKT BKR ❑ CIR P # SPH CIR # P ❑ CKT BKR LOAD VA CIRCUIT DESCRIPTION - - 792 -. - 1 A B C A B C A B C A B C A B C A B C A B C 2 1 20 720 STOREFRONT LIGHTS NOTE 1/2 SF -1 NOTE 2 792 20 3 3 4 1 20 720 STOREFRONT LIGHTS NOTE 1/2 - - 792 - - 5 6 1 20 500 EWC NOTE 2 - - 792 - 7 8 1 20 SPARE SF -2 NOTE 2 792 20 3 9 10 1 20 SPARE - - 792 - 11 12 1 20 SPARE SPARE 20 1 13 14 SPACE SPARE 20 1 15 16 SPACE SPARE 20 1 17 18 SPACE SPACE 19 20 SPACE SPACE 21 22 SPACE SPACE 23 24 SPACE LOAD SUMMARY: CONNECTED FEEDER/SERVICE CALCULATION .7d $ 3X M .:.. " 14TARYFE T `. � s '? 0 �.�- ;4 r �i .. r VI -I Primary: Motor (FLA): Avail. Fault (lafc): Feeder Size: feeder Length (L): Parallel Sets; Power Factor % Feeder/Load Amps: 'C' Value: 'Volt Drop Value: Volts Amps Awg.n, Ft. Amps Cu VI -I Secondary: Transformer KVA: Transformer Z%: Avail. Fault (laic): Feeder Size: Feeder Length (L): Parallel Sets: Power Factor % Feeder/Load Amps: 0' Value: 'Volt Drop' Value: Volts KVA Amps Aw4 Ft. Amps Cu LIGHTING 1.44 KVA 1.80 LARGEST MOTOR 2.38 KVA 2.97 KVA (125%) MOTORS 2.38 KVA 2.38 KVA (100%) RECEPT 0.00 KVA 0.00 KVA(10KVA®100%,REMAIN050%) KITCHEN EQUIPMENT 0.00 KVA 0.00 KVA (65%) ELECTRONIC LOADS 0.00 KVA 0.00 KVA (100%) ELECTRIC HEATING 0.00 KVA 0.00 KVA (100%) MISC. 0.50 KVA 0.50 KVA (100%) " '€, _' a ;+.' ;+` .. ; 208 €,', " 13 6972 25 1 90% 60 TOTALS 7 KVA 8 KVA HI -PHASE 19 AMPS 21 AMPS 22 A 3826 619 a, "' ` r ro NOTES: 1. VIA TIME CLOCK 2. PROVIDE LOCK ON DEVICE 3. 4. 5, Prim 'Vdrop = 0.78 Volts CURRENT CALCULATIONS: Prim Vdrop% Isc (Xfmr Secondary) - Amps Sec Vdrop = NA Volts Isc (At Panel) = 5055 Amps Sec Vdrop% _ Isc (w/ motor conlrib:) = 5121 Amps (y ` ,;" - .1 PER PHASE A: 2 KVA B: 2 KVA C: 2 KVA E.C. TO VISIT EXISTING SPACE AND SURVEY EXISTING CONDITIONS PRIOR TO BID. VERIFY EXISTING CONDUIT/CONDUCTORS/METERING AND ROUTING OF CONDUIT TO LANDLORD'S SPACE. REPORT ANY DISCREPANCIES TO ELECTRICAL DESIGNER. CONTACT LANDLORD'S ELECTRICAL CONTRACTOR TO GAIN ACCESS TO LANDLORD ELECTRICAL DISTRIBUTION ROOM IN ORDER TO TURN OFF SERVICE FOR EXISTING SPACE. THIS RISER DIAGRAM REPRESENTS (AS ACCURATELY AS POSSIBLE) THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. FIELD VERIFY ALL SIZES OF EQUIPMENT, CONDUCTORS, FUSES, ETC. SIZES SHOWN ON DRAWING SHALL BE CONSIDERED A MINIMUM. ANY EXISTING EQUIPMENT CONDUCTORS, FUSES, ETC. WHICH DO NOT MEET MINIMUM SHALL BE REPLACED TO MEET MINIMUM. TENANT MUST VERIFY LOCATION AND PLACEMENT OF ELECTRICAL EQUIPMENT. ANY MODIFICATIONS, RELOCATIONS, OR ADDITIONS REQUIRED BY TENANT'S DESIGN SHALL BE PROVIDED AND INSTALLED BY TENANT AT TENANT'S EXPENSE. NO SCALE PATRICK G. BLESS architecture • planning • interior design PATRICK G.'BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info@cmarch.com CONTACT: ANTHONY JOHNSON ajohnson©cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: 1-'-. 3. r 5 IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MATTHEW W. FULTS SIGNATURE 10-09-2015 DATE ISSUED 087346-1 REG. NO. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12345 SUITE #7 STORE #4197 SHEET TITLE: ELECTRICAL DETAILS AND SCHEDULES REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY: KO Q COPYRIGHT PATRICK G. GLEES, AIA 2015 1.6 BALLASTS FOR LINEAR FLUORESCENT LAMPS A. General Requirements for Electronic Ballasts: 1. Comply with UL 935 and with ANSI C82.11. 2. Designed for type and quantity of lamps served. 3. Ballasts shall be designed for full light output unless another BF, dimmer, or bi-level control is indicated. 4. Sound Rating: Class A. 5. Total Harmonic Distortion Rating: Less than 20 percent. 6. Transient Voltage Protection: IEEE C62.41.1 and IEEE C62.41.2, Category A or better. 7. Operating Frequency: 42 kHz or higher. B. Lamp Current Crest Factor: 1.7 or less. 9. BF: 0.88 or higher unless otherwise indicated. 10. Power Factor: 0.95 or higher. B. Ballasts for Low -Temperature Environments: 1. Temperatures 0 Deg F and Higher: Electronic type rated for 0 deg F starting and operating temperature with indicated lamp types. 1.7 BALLASTS FOR HID LAMPS A. Electronic Ballast for Metal -Halide Lamps: Include the following features unless otherwise indicated: 1. Minimum Starting Temperature: Minus 20 deg F for single -lamp ballasts. 2. Rated Ambient Operating Temperature: 130 deg F. 3. Lamp end -of -life detection and shutdown circuit. 4. Sound Rating: Class A. 5. Total Harmonic Distortion Rating: Less than 20 percent., 6. Transient Voltage Protection: IEEE C62.41.1 and IEEE C62.41.2, Category A or better. 7. Lamp Current Crest Factor: 1.5 or less. 8. Power Factor: 0.90 or higher. 9. Interference: Comply with 47 CFR 18, Ch. 1, Subpart C, for limitations on electromagnetic and radio-frequency interference for nonconsumer equipment. 10. Protection: Class P thermal cutout. 1.8 EXIT SIGNS A. General Requirements for Exit Signs: Comply with UL 924; for sign colors, visibility, luminance, and lettering size, comply with authorities having jurisdiction. B. Internally Lighted Signs: 1. Lamps for AC Operation: LEDs, 50,000 hours minimum rated lamp life. 2. Self -Powered Exit Signs (Battery Type): Integral automatic charger in a self-contained power pack. a. Battery: Sealed, maintenance -free, nickel -cadmium type. b. Charger: Fully automatic, solid-state type with sealed transfer relay. c. Operation: Relay automatically energizes lamp from battery when circuit voltage drops to 80 percent of nominal voltage or below. When normal voltage is restored, relay disconnects lamps from battery, and battery is automatically recharged and floated on charger. d. Test Push Button: Push -to -test type, in unit housing, simulates Loss of normal power and demonstrates unit operability. e. LED Indicator Light: Indicates normal power on. Normal glow indicates trickle charge; bright glow indicates charging at end of discharge cycle. 1.9 EMERGENCY LIGHTING UNITS A. General Requirements for Emergency Lighting Units: Self-contained units complying with UL 924. 1. Battery: Sealed, maintenance -free, lead -acid type. 2. Charger: Fully automatic, solid-state type with sealed transfer relay. 3. Operation: Relay automatically turns lamp on when power -supply circuit voltage drops to 80 percent of nominal voltage or below. Lamp automatically disconnects from battery when voltage approaches deep -discharge level. When', normal voltage is restored, relay disconnects lamps from battery, and battery is automatically recharged and floated on charger. 4. Test Push Button: Push -to -test type, in unit housing, simulates loss of normal power and demonstrates unit operability. 5. LED Indicator Light: Indicates normal power on. Normal glow indicates trickle charge; bright glow indicates charging at end of discharge cycle. 6. Wire Guard: Heavy -chrome -plated wire guard protects lamp heads or fixtures. 1.10 FLUORESCENT LAMPS A. T8 rapid -start lamps, 2950 initial lumens (minimum), CRI 85 (minimum), color temperature 3500 K, and average rated life 30,000 hours unless otherwise indicated. 1.11 HID LAMPS A. Ceramic, Pulse -Start, Metal -Halide Lamps: Minimum CRI 80, and color temperature 4000 K. GENERAL NOTES 1. Refer to architectural elevations and reflected ceiling plan for exact location of lighting fixtures and devices. 2. Letter thus: "A" -Indicates type of lighting fixtures. refer to lighting fixture types as noted on the lighting fixture schedule. 3. Verify location of all floor outlets with architect prior to rough -in. Existing concrete floor to be cut and trenched as required. 4. Data telephone and television conduit shall be minimum %" unless otherwise noted on drawings. 5. Do not scale drawings. Verify dimensions in field prior to commencement of work. 6. Final connections to equipment shall be per manufacturer's approved wiring diagrams, details, and instructions. It shall be the contractor's responsibility to provide materials and equipment compatible with equipment actually supplied. 7. All empty raceway systems shall have a pull -wire or equal and shall be identified at all junction, pull, and termination points, using permanent metallic tags. Tag shall indicate intended use of conduit, origination and termination points of each individual conduit. 8. It is the intent of these drawings and specifications to establish a standard of quality. The engineer reserves the right to approve methods and materials not reflected herein. 9. Contractor shall review architectural, structural, and mechanical drawings and shall provide lights, switches, receptacles, telephone outlets, equipment connections, etc., and associated circuiting in new and remodeled areas, even if such areas are not shown on electrical drawings. layouts, fixture types, quantities, and spacing shall be in accordance with similar areas on this project. Contractor shall include costs for the above in his bid. 10. Work shall be performed in a workmanlike manner to the satisfaction of the architect. 11. Work, materials and equipment shall conform to the latest editions of local, state of New York, and national codes and ordinances. 12. Provide permits and inspections required. 13. Guarantee the installation against defects in materials and workmanship which may occur under normal usage for a period of one year after owner's acceptance. Defects shall be promptly remedied without cost to the owner. 14. Verify that exact location of equipment to be furnished by others prior to rough -in. 15. Systems shall be tested for proper operation. If tests show that work is defective, contractor shall make corrections necessary at no cost to owner. 16. Contractor shall be responsible for replacing equipment which is damaged due to incorrect field wiring or factory wiring in equipment provided by this contractor. 17. Systems shall be complete, operable, and ready for continuous operation. lights, switches, receptacles, motors, etc. shall be connected and operable. 18. All wiring shall be installed in listed metallic raceways. Raceways in slab -on -grade or below grade shall be schedule 40 PVC. Transitions from below to above grade shall be with rigid steel elbows with PVC jacket or provided equal protection. EMT fittings shall be malleable iron or steel. connectors shall be insulated throat type. 19. Final connections to motors, transformers, and other vibrating equipment shall be with liquid -tight flex metal conduit and fittings. Do not secure conduits, disconnects, or devices to ductwork or mechanical equipment. 20. All electrical systems components shall be listed or labeled by UL or other recognized testing facility. 21. Electrical contractor shall properly balance all branch circuits between all phases of the system, regardless of circuiting indicated. 22. Electrical contractor shall obtain a copy of landlord's design criteria, this guide supersedes drawings and specification (i.e. manufacturer, etc.). 23. All receptacle outlets and cover plates to be black unless noted otherwise. 24. Multi -phase loads shall be protected by multi -pole circuit breakers having common trip and single handle. Handle ties and trough clips or pins are unacceptable. 25. Multi -wire branch circuits shall require a multi -pole breaker as a means to simultaneously disconnect all ungrounded conductors at the point where the branch circuit originates per NEC 210.4(B). REMODELING 1. Circuit numbers shown on these drawings shall not necessarily correspond to actual circuit breaker numbers. Contractor shall connect to existing circuit breakers abandoned by demolition/remodeling. 2. Where an electrical system in the space is called out to be connected with an existing system the contractor shall be responsible for the coordination of the point of connection as well as the means of connection with the existing system. Contractor shall provide all new hardware components required to integrate the new devices/components into the existing headend or system control panel. Contractor shall provide all system software upgrades required to incorporate new components into existing system. 3. Wherever the installation of electrical equipment conflicts with existing conditions not mentioned in the plans or the specifications, the contractor shall determine a satisfactory alternative means of installation and obtain approval from the engineer before actual equipment installation. 4. Contractor shall be responsible to field verify existing equipment or circuits that are remaining to be reconnected to new or existing switchboards/ponelboards. provide switches, receptacles, conduit, wire, etc. as required to restore continuity of circuit(s). LIGHTING 1. Recessed light fixtures installed in gyp board or plaster ceilings shall have plaster frames installed prior to ceiling material. 2. Verify type of ceiling construction for proper mounting of all recessed light fixtures. Installation of light fixtures shall comply with all international building code requirements. 3. Recessed lighting fixtures installed into metal suspended ceiling systems for lay -in tiles and panels shall be installed and supported in accordance with the international building code ASTM C635 and C636. 4. Fixtures installed in "light-duty ceiling systems"shall have separate supporting members. fixtures installed in "intermediate -duty and heavy-duty ceiling systems"shall have separate supporting members when the weight of the fixtures exceeds the deflection and rotation requirements of ASTM C636 2.7.2,3 and 4. 5. Refer to reflected ceiling plan for exact location and mounting heights of all lighting fixtures within the entire tenant space. 6. Electrical contractor shall make final adjustments of adjustable downlights along with owner representative. 7. All ceiling mounted EDU units shall be recessed. 8. Emergency fixtures and exit lights shall be fed via un -switched hot circuit. FIRE ALARM 1. Fire alarm system. contractor shall provide conduit for devices, coordinate with mall vendor. ��= y, ° ,_ 1 PATRICK BON ,'i. v H G. BLEES architecture - planning - interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MATTHEW W. FULTS SIGNATURE 10-09-2015 DATE ISSUED 087346.-1 REG. N0. F�Co. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: ELECTRICAL SPECIFICATIONS AND GENERAL NOTES REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY_ KO E5 COPYRIGHT PATRICK G. BLEES, AIA 2015 a �r . "n SECTION 16 0500 -COMMON WORK RESULTS FOR ELECTRICAL SECTION 16 0533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 16 2416 - PANELBOARDS 1.8 WALL PLATES 1.1 SUMMARY A. Section Includes: 1.1 SUMMARY 1.1 SUMMARY A. Single and combination types to match corresponding wiring devices. 0 1. Common electrical installation requirements. A. This Section includes raceways, fittings, boxes, enclosures and cabinets for electrical Y ' 9 ' A. Section includes lighting and appliance branch -circuit onelboards. 9 9 PP P 1. Plate -Securing Screws: Metal with head color to match plate finish. 1.2 COMMON REQUIREMENTS FOR ELECTRICAL INSTALLATION wiring. 1.2 QUALITY ASSURANCE 2. Material for Finished Spaces: Smooth, high -impact thermoplastic. A. Comply with NECA L 1.2 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in 3. Material for Unfinished Spaces: Galvanized steel B. Measure indicated mounting heights to bottom of unit for suspended' e 9 g items and to A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. PP 4. Material for Damp Locations: Cast aluminum with spring-loaded lift cover, and listed center of unit for wall -mounting items. 9 NFPA 70, A title 100, by a testing agency acceptable to authorities having jurisdiction, and 1.3 GENERAL REQUIREMENTS FOR PANELBOARDS and labeled for use in "wet locations:' Paintable. y C. Headroom Maintenance: If mounting heights or other location criteria are not marked for intended use. A. Enclosures: Flush- and surface -mounted cabinets. B. Wet -Location, Weatherproof Cover Plates: NEMA 250, complying with type 3R indicated, arrange and install components and equipment to provide maximum possible B. Comply with NFPA 70. 1. Rated for environmental conditions at installed location, weather -resistant ,die- cast aluminum with lockable cover. Paintable. headroom consistent with. these requirements. 1.3 METAL CONDUIT AND TUBING D. Equipment: Install to facilitate service, maintenance, and repair or replacement of A. Rigid Steel Conduit: ANSI C80.1. a. Indoor Dry and Clean Locations: NEMA 250, Type L 1.9 FINISHES components of both electrical equipment and other nearby installations. Connect in such b. Outdoor Locations: NEMA 250, Type 3R, A. Color: Wiring device catalog numbers in Section Text do not designate device color. a way as to facilitate future disconnecting with minimum interference with other items in BMC: ANSI C806 , .. 2. Front: Secured to box with concealed trim clamps. For surface -mounted fronts, 1. Wiring Devices and coverplates: As directed by the Architect, unless otherwise the vicinity. Y C. EMT: ANSI C80.3. match box dimensions; for flush -mounted fronts, overlap box. indicated or required b NFPA 70 or device listing. Architect reserves the right to re uest 9 Y 9• 9 9 E. Right of Way: Give to in systems installed at a required slope. 9 Y piping 9 Y 9 P D. FMC: Zinc -coated steel. 3. Directory Card: Inside panelboard door, mounted in transparent card holder. multiple device finishes. F. Contractor shall provide rough -in for and connect to the following equipment E. LFMC: Flexible steel conduit with PVC jacket. B. Phase, Neutral, and Ground Buses: Tn-plated aluminum. 1.10 INSTALLATION furnished ;by others. Equipment will be provided by other contractors or owner. Secure F. Fittings for Conduit (Including all Types and Flexible and Liquidtight), EMT, and Cable: C. A. Comply with NECA 1, including the mounting heights listed in that standard, unless rough -in information, connection requirements, and templates from equipment supplier. NEMA FB 1; listed for type and size raceway with which used, and for application and Panelboard Short -Circuit Current Rating: Fully rated to interrupt symmetrical otherwise noted. See drawings. Verify all equipment voltage and power requirements: environment in which installed. short-circuit current available at terminals. _ 1. Plumbing and HVAC equipment. 1.4 LIGHTING AND APPLIANCE BRANCH -CIRCUIT PANELBOARDS Conductors: C onductors: 2. Electric motors: 1. Conduit Fittings for Hazardous (Classified) Locations: Comply with UL 886. A. Manufacturers: Subject to compliance with requirements, provide products by one of 1. The length of free conductors at outlets for devices shall meet provisions of NFPA 1.3 FIRE -STOPPING 2. Fittings for EMT: Steel, set -screw, or compression type. the following: ti l Arce , wou without 300 70, pigtails. A. Apply fire -stopping to penetrations of fire -rated floor and wall assemblies for 1.4 NONMETALLIC CONDUIT AND TUBING 1. Eaton Electrical Inc.; Cutler -Hammer Business Unit. 2. Existing Conductors: electrical installations to restore original fire -resistance rating of assembly. Fire -stopping A. ENT: NEMA TC 13. 2. General Electric Company; GE Consumer & Industrial - Electrical Distribution. a. Cut back and pigtail, or replace all damaged conductors. materials and installation requirements are specified in Division 07 Section "Penetration B. RNC: NEMA TC 2, Type EPC -40 -PVC, unless otherwise indicated. 3. Siemens Energy & Automation, Inc. b. Pigtoiling existing conductors is permitted provided the outlet box is large enough. Fire -stopping" C. LFNC: UL 1660. 4. Square D; a brand of Schneider Electric. D. Receptacle Orientation: 1.4 SEISMIC REQUIREMENTS D. Fittings for ENT and RNC: NEMA TC 3; match to conduit or tubing type and B. Ponelboards: NEMA PB 1 lighting and u g g appliance branch -circuit type. 1. Install ground pin of vertically mounted receptacles down, and on horizontally C. Provide bracing and supports to meet code required seismic ratings, material mounted receptacles to the right. C. Mains: Circuit breaker. E Fittings for LFNC: UL 5148. E. Receptacles Connections: SECTION 16 0519 - LOW -VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1.5 BOXES, ENCLOSURES, AND CABINETS D. Branch Overcurrent Protective Devices: Bolt -on circuit breakers, replaceable without 1. Provide pigtails in each receptacle box, Do not use feed through lugs on receptacles. 1.1 SUMMARY disturbing adjacent units. Where multi -wire branch circuits are utilized provide multi -pole A. Sheet Metal Outlet and Device Boxes: NEMA OS 1. circuit breakers or manufacturer provided handle ties. F. Dimmers: I A. This Section includes the following: B. Cast -Metal Outlet and Device Boxes: NEMA FB 1, aluminum, Type FD, with Basketed E. Doors: Concealed hinges; secured with flush latch with tumbler lock; keyed alike. 1. Install dimmers within terms of their listing. 9• ^, 1. Building wires and cables rated 600 V and less. cover. F. Service entrance rated. 2. Install unshaved neutral conductors on line and load side of dimmers according to N 2. Connectors, splices, and terminations rated 600 V and less. C. Nonmetallic Outlet and Device Boxes: NEMA OS 2, 1.5 DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES manufacturers' device listing conditions in the written instructions. 1.2 QUALITY ASSURANCE 1.6 RACEWAY APPLICATION A. Manufacturers: Subject to compliance with requirements, provide products byone of A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in A. Outdoors: Apply raceway products as specified below, unless otherwise indicated: the following: SECTION 16 2816 - ENCLOSED SWITCHES NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and 1 Exposed Conduit: Rigid steel conduit or RNC, Type EPC -40 -PVC. 1. Eaton Electrical Inc.; Cutler -Hammer Business Unit. 1.1 SUMMARY marked for intended use. B. Comply with NFPA 70. 2. Concealed Conduit, Aboveground: Rigid steel conduit or RNC, Type EPC -40 -PVC. 2. General Electric Company; GE Consumer & Industrial - Electrical Distribution. A. Section Includes: 1.3 .CONDUCTORS AND. CABLES 3. Underground Conduit: RNC, Type EPC -40 -PVC, direct buried. 3. Siemens Energy & Automation, Inc. 1. Fusible switches. A. Copper and Aluminum Conductors: Comply with NEMA WC 70. 4. Connection to Vibrating Equipment (Including Transformers and Hydraulic, Pneumatic, 4. Square D; a brand of Schneider Electric, 2. Non -fusible switches. B. Conductor Insulation: Comply with NEMA WC for Types THHNand XHHW. Electric Solenoid, or Motor -Driven Equipment): LFMC. B. Molded -Case Circuit Breaker (MCCB): Comply with UL 489, with interrupting capacity 3. Enclosures. 5. Boxes and Enclosures, Aboveground: NEMA 250, Type 3R. to meet available fault currents. 1.2 QUALITY ASSURANCE C. Multi conductor Cable: Comply with NEMA W WC 70 for metal -clad ad cable, Type MC with ground wire. following B. Comply with the f wng indoor applications, unless otherwise indicated: - 1. Thermal Magnetic Circuit Breakers: Inverse time -current element for low-level A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in 1.4 CONDUCTOR MATERIAL APPLICATIONS 1. Exposed, Not Subject to Physical Damage: EMT. overloads, and instantaneous magnetic trip element for short circuits. Adjustable magnetic NFPA 70, by a qualified testing agency, and marked for intended location and application. A. Feeders: Copper for feeders smaller than No. 3 AWG; copper or aluminum for ? Exposed, Not Subject to Severe Physical Damage: EMT. trip setting for circuit -breaker frame sizes 250 A and larger. 1.3 MANUFACTURERS feeders No. 4 AWG and larger. Solid for No. 12 AWG and smaller; stranded for No. 10 3. Exposed and Subject to Severe Physical Damage: Rigid steel conduit. 2, GFCI Circuit Breakers: Single- and two -pole ale confi urations with Class 9 P 9 A A. Manufacturers: Subject to compliance with requirements, provide products by one of AWG and larger. 4. Concealed in Ceilings and Interior Walls and Partitions: EMT. ground -fault protection (6-mA trip). the following: B. Branch Circuits: Copper. Solid for No. 12 AWG and smaller; stranded for No. 10 3. Ground -Fault Equipment Protection (GFEP) Circuit Breakers: Class B ground -fault 1. Eaton Electrical Inc.; Cutler -Hammer Business Unit. AWG and larger. 9 5. Connection to Vibrating Equipment (Including Transformers and Hydraulic, Pneumatic, Electric Solenoid, Motor -Driven Equipment): FMC, LFMC in damp protection (30-mA trip). Z. General Electric Company; GE Consumer &industrial -Electrical Distribution. or except use or wet 1.6 INSTALLATION .; 1.5 CONDUCTOR INSULATION AND MULTI -CONDUCTOR CABLE APPLICATIONS AND WIRING locations. 3. Siemens Energy & Automation, Inc. 17f METHODS 6. Damp or Wet Locations: Rigid steel conduit. A. AInstall filler plates in unused spaces. 4. Square D; a brand of Schneider Electric. tN A. Service Entrance: Type THHN-THWN, single conductors in raceway or Type XHHW, 7. Boxes and Enclosures: NEMA 250, Type 1, except use NEMA 250, Type 4, B. Comply with NECA 1. 1.4 FUSIBLE SWITCHES t- single conductors in raceway, nonmetallic in dam or wet locations. P 1.7 IDENTIFICATION A. Type GD, General Duty, Single Throw, ac, 800 A and Smaller: and B. Exposed Feeders: Type THHN-THWN, single conductors in raceway. P YP 9 Y A. Create a directory to indicate installed circuit loads and incorporating Owner's final NEMA KS 1, horsepower rated, with cartridge fuse interiors to accommodate indicated ge fu e di C. Feeders Concealed in Ceilings, Walls, Partitions, and Crawlspaces: Type THHN-THWN, SECTION 16 0553 _DENTIFICATION FOR ELECTRICAL SYSTEMS room designations. Obtain approval before installing. Use a computer or typewriter to fuses, lockable handle with capability to accept two padlocks, and interlocked with cover in single conductors in raceway. directory; handwritten directories are not acceptable. closed position. D. Feeders Concealed in Concrete, below Slabs -on -Grade, and Underground: Type 1.create SUMMARY B. Panelboard Nameplates: Label each pcomplying p panelboard with a nameplate with 1.5 NON -FUSIBLE SWITCHES THHN-THWN, single conductors in raceway. A. A. Section Includes: requirements for identification specified in Division 26 Section "Identification for Electrical A. Type GD, General Duty, Single Throw, 600 A and Smaller: UL 98 and NEMA KS 1, _` E Exposed Branch Circuits, Including in Crawlspaces: Type THHN-THWN, single 1. Identification for raceways. Systems" horsepower rated, lockable handle with capability to accept two padlocks, and interlocked conductors in raceway. ' 2. Identification of power and control cables. with cover in closed position. F. Branch Circuits Concealed in Ceilings, Walls, and Partitions: Type THHN-THWN, single 3. Identification for conductors. SECTION 16 2726 - WIRING DEVICES 1.6 ENCLOSURES conductors in raceway or Metal -clad cable, Type MC. 4. Equipment identification labels. 1.1 SUMMARY A. Enclosed Switches: NEMA AB 1, NEMA KS 1, NEMA 250, and UL 50, to comply with G. Branch Circuits Concealed Co - i Concrete, below Slabs -on -Grade, and Underground: 5. Miscellaneous identification products. A. This Section includes the following: environmental conditions at installed location. Type THHN-THWN, single conductors in raceway. 1. Receptacles, receptacles with integral GFCI, and associated device plates. 1. Indoor, Dry and Clean Locations: NEMA 250, Type i• 1.6 INSTALLATION OF CONDUCTORS AND CABLES 1.2 EQUIPMENT IDENTIFICATION LABELS 2. Snap switches and wall -box dimmers. 1 2. Outdoor Locations: NEMA 250, Type 3R. A. Conceal cables in finished walls ceilings, and floors unless otherwise indicated. A. Self -Adhesive, Engraved, Laminated Acrylic or Melamine Label: Adhesive backed, with 3. Wall -switch occupancy. sensors. 1.7 IDENTIFICATION B. Install exposed cables parallel and perpendicular to surfaces of exposed structural white letters on a dark -gray background. Minimum letter height shall be 3/8 inch. 1.2 MANUFACTURERS A. Label each enclosure with engraved metal or laminated -plastic nameplate. ;, members, and follow surface contours where possible. 1.3 IDENTIFICATION SCHEDULE A. Manufacturers' Names: Shortened versions (shown in parentheses) of the following SECTION 16 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS A. Accessible Raceways and Metal -Clad Cables, 600 V or Less, for Service, Feeder, and manufacturers' names are used in other Part 2 articles: SECTION 16 5100 - LIGHTING Branch Circuits More Than 30 A, and 120 V to ground: Install labels at 30 -foot 1. Cooper Wiring Devices; a division of Cooper Industries, Inc. (Cooper). 1.1 SUMMARY 1.1 SUMMARY maximum intervals. A. This Section includes methods and materials for grounding systems and equipment. B. Power -Circuit Conductor Identification, 600 V or Less: For conductors in vaults, pull 2. Hubbell Incorporated; Wiring Device-Kellems (Hubbell). A. Section Includes: 1.2 QUALITY ASSURANCE and junction boxes, manholes, and handholes, use color -coding conductor tape to identify 3. Leviton Mfg. Company Inc. (Leviton). 1. Interior lighting fixtures, lamps, and ballasts. A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in the phase. 4. Pass & Seymour/Legrand; Wiring Devices & Accessories (Pass & Seymour). 2. Emergency lighting units. NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and 1. Color -Coding for Phase Identification, 600 V or Less: Use colors listed below for 5. Lutron Electronics. 3. Exit signs. marked for intended use, ungrounded conductors. 1.3 STRAIGHT BLADE RECEPTACLES 4. Lighting fixture supports. B. Comply with UL 467 for grounding and bonding materials and equipment, PY 9 9 9A. a. Color shall be factory applied or field applied far sizes larger than No. 8 AWG, if Convenience Receptacles, 125 V, 20 A: Comply with NEMA WD 1, NEMA WD 6 1.2 QUALITY ASSURANCE 1.3 APPLICATIONS th h di it auorities having jurisdiction perm. configuration 5-20R, and UL 498. A. A. Conductors: Install solid conductor for No. 12 AWG and smaller, and stranded b. Colors for 208/120-V Circuits: b.Colors for 480/277-V Circuits: 1 .4 GFCI RECEPTACLES Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. conductors for No. 10 AWG and larger, unless otherwise indicated. 1) Phase A: Black. I) Phase A: Brown. A. General Description: Straight blade, feed -through type. Comply with NEMA WD 1, 1.3 EXTRA MATERIAL 1.4 EQUIPMENT GROUNDING 2) Phase B: Red. 2)Phase B: Orange. NEMA WD 6, UL 498, and UL 943, Class A, and include indicator light that is lighted when A. Furnish extra materials described below that match products installed and that ore A. Install insulated equipment grounding conductors with the following items, in addition 3) Phase C: Blue. 3) Phase C: Yellow. device is tripped. packaged with protective covering for storage and identified with labels describing contents, to those required by NFPA 70: 4) Neutral: White. 4) Neutral: Gray. B. Duplex GFCI Convenience Receptacles, 125 V, 20 A. 1. Lamps: 1 for every 10 of each type and rating installed unless noted otherwise. 1. Feeders and branch circuits. C. Equipment Identification Labels: On each unit of equipment, install unique 1.5 SNAP SWITCHES Furnish at least one of each type. Provide 1 for every 1 of each 12V lamp. 2. Lighting circuits, designation label that is consistent with wiring diagrams, schedules, and the Operation and A. Comply with NEMA WD 1 and UL 20. 2. Plastic Diffusers and Lenses: 1 for every 100 of each type and rating installed. 3. Receptacle circuits. Maintenance Manual. Apply labels to disconnect switches and protection equipment, central B. Switches, 120/277 V, 20 A: Furnish at least one of each type. 4. Single-phase motor and appliance branch circuits. or master units, control panels, control stations, terminal cabinets, and racks of each 1.6 WALL -BOX DIMMERS 3. Ballasts: 1 for every 30 of each type and rating installed. Furnish at least one of system. Systems include power, lighting, control, communication, signal, monitoring, and each type. 5. Three-phase motor and appliance branch circuits, alarm systems unless equipment is provided with its own identification. Dimmer Switches: Modular, full -wave, solid units with integral, quiet on-off state s switches, with audible frequency and EMI/RFIsuppression filters. 4. Globes and Guards: 1 for every 20 of each type and rating installed. Furnish at least one of each type. 3 ;SECTION 16 0529 -HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS B. Control: Continuously adjustable slider; with single -pole or three-way switching. Comply with UL 1472. 14 MANUFACTURERS -9 ri 1.1 SUMMARY C. Incandescent Lamp Dimmers: 120 V; control shall fallow square -law dimming curve. A. Products: Subject to compliance with requirements, provide one of the products w A. Section includes: On-off switch positions shall bypass dimmer module. indicated on Drawings. 0 1. Han ers and su orts for electrical e ui ment ands stems• 9 PP 9 P Y 1. 60OW unless noted otherwise on Ions dimmers shall re uire no de -rutin when P ; q 9 1.5 GENERAL REQUIREMENTS FOR LIGHTING FIXTURES AND COMPONENTS 0 2. Construction requirements for concrete bases. ganged with other devices. A. Recessed Fixtures: Comply with NEMA LE 4 for ceiling compatibility for recessed - 1.2 PERFORMANCE REQUIREMENTS 2. Dimmer used for electronic low volts a transformers shall be rated for electronic low 9 fixtures. 0 A. Design supports for multiple raceways capable of supporting combined weight of voltage. B. Incandescent Fixtures: Comply with UL 1598. supported systems and its contents. D. Fluorescent Lamp Dimmer Switches: Modular; compatible with dimmer ballasts; trim C. Fluorescent Fixtures: Comply with UL 1598. 0 B. Design equipment supports capable of supporting combined operating weight of potentiometer to adjust low-end dimming; dimmer -ballast combination capable of D. HID Fixtures: Comply with UL 1598• Metal Parts: Free of burrs and sharp corners ,� supported equipment and connected systems and components. consistent dimming with low end not greater than 20 percent of full brightness. and edges. 0 at 1.3 QUALITY ASSURANCE 1.7 OCCUPANCY SENSORS E Sheet Metal Components: Steel unless otherwise indicated. Form and support to A. Comply with NFPA 70. A. Wall -Switch Sensors: prevent warping and sagging. 1. Available Products: Subject to compliance with requirements, products that may be F. Doors, Frames, and Other Internal Access: Smooth operating, free of light leakage v 0 incorporated into the Work include, but are not limited to, the following: under operating conditions, and designed to permit relamping without use of tools. M a. Sensor Switch WSD-PDT-V. Designed to prevent doors, frames, lenses, diffusers, and other components from falling i ro accidentally during relamping and when secured in operating position. ro b. Hubbell LHMTSI 0 0 c. Watt Stopper DW -100 G. Diffusers and Globes: - I ::�i I I I d. Leviton OSSMT-MD 1. Acrylic Lighting Diffusers: 100 percent virgin acrylic plastic. High resistance W 0 yellowing and other changes due to aging, exposure to heat, and UV radiation. rr e. Equals a. Lens Thickness: At least 0.125 inch minimum unless otherwise indicated. tet' 2. Description: Dual-technologyt Ultrasonic/Phonic), 120 277 e PIR and Ultrasonic V, ) / b. UV stabilized. C) U adjustable time delay up to 20 minutes, 100 -degree field of view, with a minimum ocoverage area of 400 sq. ft.. 2. Glass: Annealed crystal glass unless otherwise indicated. 1.6 BALLASTS FOR LINEAR FLUORESCENT LAMPS A. General Requirements for Electronic Ballasts: 1. Comply with UL 935 and with ANSI C82.11. 2. Designed for type and quantity of lamps served. 3. Ballasts shall be designed for full light output unless another BF, dimmer, or bi-level control is indicated. 4. Sound Rating: Class A. 5. Total Harmonic Distortion Rating: Less than 20 percent. 6. Transient Voltage Protection: IEEE C62.41.1 and IEEE C62.41.2, Category A or better. 7. Operating Frequency: 42 kHz or higher. B. Lamp Current Crest Factor: 1.7 or less. 9. BF: 0.88 or higher unless otherwise indicated. 10. Power Factor: 0.95 or higher. B. Ballasts for Low -Temperature Environments: 1. Temperatures 0 Deg F and Higher: Electronic type rated for 0 deg F starting and operating temperature with indicated lamp types. 1.7 BALLASTS FOR HID LAMPS A. Electronic Ballast for Metal -Halide Lamps: Include the following features unless otherwise indicated: 1. Minimum Starting Temperature: Minus 20 deg F for single -lamp ballasts. 2. Rated Ambient Operating Temperature: 130 deg F. 3. Lamp end -of -life detection and shutdown circuit. 4. Sound Rating: Class A. 5. Total Harmonic Distortion Rating: Less than 20 percent., 6. Transient Voltage Protection: IEEE C62.41.1 and IEEE C62.41.2, Category A or better. 7. Lamp Current Crest Factor: 1.5 or less. 8. Power Factor: 0.90 or higher. 9. Interference: Comply with 47 CFR 18, Ch. 1, Subpart C, for limitations on electromagnetic and radio-frequency interference for nonconsumer equipment. 10. Protection: Class P thermal cutout. 1.8 EXIT SIGNS A. General Requirements for Exit Signs: Comply with UL 924; for sign colors, visibility, luminance, and lettering size, comply with authorities having jurisdiction. B. Internally Lighted Signs: 1. Lamps for AC Operation: LEDs, 50,000 hours minimum rated lamp life. 2. Self -Powered Exit Signs (Battery Type): Integral automatic charger in a self-contained power pack. a. Battery: Sealed, maintenance -free, nickel -cadmium type. b. Charger: Fully automatic, solid-state type with sealed transfer relay. c. Operation: Relay automatically energizes lamp from battery when circuit voltage drops to 80 percent of nominal voltage or below. When normal voltage is restored, relay disconnects lamps from battery, and battery is automatically recharged and floated on charger. d. Test Push Button: Push -to -test type, in unit housing, simulates Loss of normal power and demonstrates unit operability. e. LED Indicator Light: Indicates normal power on. Normal glow indicates trickle charge; bright glow indicates charging at end of discharge cycle. 1.9 EMERGENCY LIGHTING UNITS A. General Requirements for Emergency Lighting Units: Self-contained units complying with UL 924. 1. Battery: Sealed, maintenance -free, lead -acid type. 2. Charger: Fully automatic, solid-state type with sealed transfer relay. 3. Operation: Relay automatically turns lamp on when power -supply circuit voltage drops to 80 percent of nominal voltage or below. Lamp automatically disconnects from battery when voltage approaches deep -discharge level. When', normal voltage is restored, relay disconnects lamps from battery, and battery is automatically recharged and floated on charger. 4. Test Push Button: Push -to -test type, in unit housing, simulates loss of normal power and demonstrates unit operability. 5. LED Indicator Light: Indicates normal power on. Normal glow indicates trickle charge; bright glow indicates charging at end of discharge cycle. 6. Wire Guard: Heavy -chrome -plated wire guard protects lamp heads or fixtures. 1.10 FLUORESCENT LAMPS A. T8 rapid -start lamps, 2950 initial lumens (minimum), CRI 85 (minimum), color temperature 3500 K, and average rated life 30,000 hours unless otherwise indicated. 1.11 HID LAMPS A. Ceramic, Pulse -Start, Metal -Halide Lamps: Minimum CRI 80, and color temperature 4000 K. GENERAL NOTES 1. Refer to architectural elevations and reflected ceiling plan for exact location of lighting fixtures and devices. 2. Letter thus: "A" -Indicates type of lighting fixtures. refer to lighting fixture types as noted on the lighting fixture schedule. 3. Verify location of all floor outlets with architect prior to rough -in. Existing concrete floor to be cut and trenched as required. 4. Data telephone and television conduit shall be minimum %" unless otherwise noted on drawings. 5. Do not scale drawings. Verify dimensions in field prior to commencement of work. 6. Final connections to equipment shall be per manufacturer's approved wiring diagrams, details, and instructions. It shall be the contractor's responsibility to provide materials and equipment compatible with equipment actually supplied. 7. All empty raceway systems shall have a pull -wire or equal and shall be identified at all junction, pull, and termination points, using permanent metallic tags. Tag shall indicate intended use of conduit, origination and termination points of each individual conduit. 8. It is the intent of these drawings and specifications to establish a standard of quality. The engineer reserves the right to approve methods and materials not reflected herein. 9. Contractor shall review architectural, structural, and mechanical drawings and shall provide lights, switches, receptacles, telephone outlets, equipment connections, etc., and associated circuiting in new and remodeled areas, even if such areas are not shown on electrical drawings. layouts, fixture types, quantities, and spacing shall be in accordance with similar areas on this project. Contractor shall include costs for the above in his bid. 10. Work shall be performed in a workmanlike manner to the satisfaction of the architect. 11. Work, materials and equipment shall conform to the latest editions of local, state of New York, and national codes and ordinances. 12. Provide permits and inspections required. 13. Guarantee the installation against defects in materials and workmanship which may occur under normal usage for a period of one year after owner's acceptance. Defects shall be promptly remedied without cost to the owner. 14. Verify that exact location of equipment to be furnished by others prior to rough -in. 15. Systems shall be tested for proper operation. If tests show that work is defective, contractor shall make corrections necessary at no cost to owner. 16. Contractor shall be responsible for replacing equipment which is damaged due to incorrect field wiring or factory wiring in equipment provided by this contractor. 17. Systems shall be complete, operable, and ready for continuous operation. lights, switches, receptacles, motors, etc. shall be connected and operable. 18. All wiring shall be installed in listed metallic raceways. Raceways in slab -on -grade or below grade shall be schedule 40 PVC. Transitions from below to above grade shall be with rigid steel elbows with PVC jacket or provided equal protection. EMT fittings shall be malleable iron or steel. connectors shall be insulated throat type. 19. Final connections to motors, transformers, and other vibrating equipment shall be with liquid -tight flex metal conduit and fittings. Do not secure conduits, disconnects, or devices to ductwork or mechanical equipment. 20. All electrical systems components shall be listed or labeled by UL or other recognized testing facility. 21. Electrical contractor shall properly balance all branch circuits between all phases of the system, regardless of circuiting indicated. 22. Electrical contractor shall obtain a copy of landlord's design criteria, this guide supersedes drawings and specification (i.e. manufacturer, etc.). 23. All receptacle outlets and cover plates to be black unless noted otherwise. 24. Multi -phase loads shall be protected by multi -pole circuit breakers having common trip and single handle. Handle ties and trough clips or pins are unacceptable. 25. Multi -wire branch circuits shall require a multi -pole breaker as a means to simultaneously disconnect all ungrounded conductors at the point where the branch circuit originates per NEC 210.4(B). REMODELING 1. Circuit numbers shown on these drawings shall not necessarily correspond to actual circuit breaker numbers. Contractor shall connect to existing circuit breakers abandoned by demolition/remodeling. 2. Where an electrical system in the space is called out to be connected with an existing system the contractor shall be responsible for the coordination of the point of connection as well as the means of connection with the existing system. Contractor shall provide all new hardware components required to integrate the new devices/components into the existing headend or system control panel. Contractor shall provide all system software upgrades required to incorporate new components into existing system. 3. Wherever the installation of electrical equipment conflicts with existing conditions not mentioned in the plans or the specifications, the contractor shall determine a satisfactory alternative means of installation and obtain approval from the engineer before actual equipment installation. 4. Contractor shall be responsible to field verify existing equipment or circuits that are remaining to be reconnected to new or existing switchboards/ponelboards. provide switches, receptacles, conduit, wire, etc. as required to restore continuity of circuit(s). LIGHTING 1. Recessed light fixtures installed in gyp board or plaster ceilings shall have plaster frames installed prior to ceiling material. 2. Verify type of ceiling construction for proper mounting of all recessed light fixtures. Installation of light fixtures shall comply with all international building code requirements. 3. Recessed lighting fixtures installed into metal suspended ceiling systems for lay -in tiles and panels shall be installed and supported in accordance with the international building code ASTM C635 and C636. 4. Fixtures installed in "light-duty ceiling systems"shall have separate supporting members. fixtures installed in "intermediate -duty and heavy-duty ceiling systems"shall have separate supporting members when the weight of the fixtures exceeds the deflection and rotation requirements of ASTM C636 2.7.2,3 and 4. 5. Refer to reflected ceiling plan for exact location and mounting heights of all lighting fixtures within the entire tenant space. 6. Electrical contractor shall make final adjustments of adjustable downlights along with owner representative. 7. All ceiling mounted EDU units shall be recessed. 8. Emergency fixtures and exit lights shall be fed via un -switched hot circuit. FIRE ALARM 1. Fire alarm system. contractor shall provide conduit for devices, coordinate with mall vendor. ��= y, ° ,_ 1 PATRICK BON ,'i. v H G. BLEES architecture - planning - interior design PATRICK G. BLEES, ARCHITECT 800 WASHINGTON AVE. N., SUITE 208 MINNEAPOLIS, MN 55401-1148 PHONE: (612) 547-1300 FAX: (612) 547-1301 E-MAIL: info®cmarch.com CONTACT: ANTHONY JOHNSON ajohnson®cmarch.com CONSULTANTS: MECH/PLBG/ELEC EMANUELSON PODAS, INC 10401 BREN RD EAST MINNETONKA, MN 55343 (952) 930-0050 SEAL: IT IS A VIOLATION OF THE LAW FOR ANY PERSON TO ALTER AN ITEM IN ANY WAY UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER. MATTHEW W. FULTS SIGNATURE 10-09-2015 DATE ISSUED 087346.-1 REG. N0. F�Co. OUTLETS AT LAKE GEORGE 1424 STATE RT 9 LAKE GEORGE NY, 12845 SUITE #7 STORE #4197 SHEET TITLE: ELECTRICAL SPECIFICATIONS AND GENERAL NOTES REVISIONS: NO: DATE: BY: PROJECT NO: 3633.0036 DRAWN BY_ KO E5 COPYRIGHT PATRICK G. BLEES, AIA 2015