Loading...
RC-000485-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 - Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000485-2016 Date Issued: Friday, January 26, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000485-2016 has been completed. Tax Map Number: 303.5-1-93 Location: 36 MEADOWBROOK RD Owner: Marcia Tyminski Applicant: William Roberts This structure may be occupied as a: Single Family Dwelling w/FP 1098 s.f. Garage 362 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the 4t property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (5]8)761-8201 ±*■ Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000485-2016 Tax Map No: 303.5-1-93 Permission is hereby granted to: Marcia Tyminski For property located at: 36 MEADOWBROOK RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvoe of Construction Owner Name: Marcia Tyminski Single Family-New $250,000.00 Owner Address: 36 Meadowbrook RD Total Value $250.000.00 Queensbury,NY 12804 Contractor or Builder's Name f Address EIectrical Inspection Agency William Roberts 9768 RT 22 Middle Granville,NY 12849 Plans&Specifications Single Family Dwelling wfFP 1098 s.f. Garage 362 s.f: $323.90 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,July 30,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ueens hur gust 4 2016 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement NCIPAI, STRUCTURE APPLICATION Office Use Onl Fe&4,k1_ 'F7D,,,:&J�C- 'D Date: cC Permit No. ec'lerD-W 110 Tax Map ID "�, j_ P?? 3 Permi e� 052-5-9%) Zone Historic? _Yes No ec Fee '/ ty-motc, b--3,4 Subdivision Name Lot# i Site Plan# Pel � Project Location o 1 zfe1 e�:&Vrt Kms' Subdivision# TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes, but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) 49,U14 MlS' C Address 3 � Phone/Email Applicant _ Address Phone/Email Contractor E!z Address 9' Phone/Email Contact Person for Building& Codes Compliance: Phone TYPP OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 2"d floor sf Total sf Height Single Family Two-Family G' 1 Multi-Family (#of units_) Townhouse Business Office Retail- Mercantile Factory-Industrial Attached Garage / D2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) GasOil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys Are there structures not shown on plot plan? Are there easements on the property? Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? Yes No c. Will the grade be changed as a result of construction Yes No d. Public water or Private well(circle one) Public Private e. Sewer or Private Septic System(circle one) Sewer Private Value of all work to be performed(labor or materials) Is d 0 DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement J description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I J we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: UV DATE: x rp SIGNATURE: tom/ Y� ADATE: lD For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: Tax Map ID TAx MAP ID: Permit No. Permit Fee ZONE: OWNER S�� PHONE/E-MAIL ADDRESS 3C.- ),vi;-7c I/B Z- Yr) INSTALLER/ PHONE/E-MAIL BUILDER ! u "&C.- CONTACT PERSON FOR BUILDING&CODE OMPLIANCE: PHONE/E-MAIL -36/ - 6 6 9 V2—I tG O TILDING ADDRESS ROOM OF INSTALL: (j 9 PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: FIREPLACE,MASONRY i tj MANUFACTURER'S FURNACE(GARAGE ONLY) INSTALLATION MANUAL MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: ; Model#: Listed by: Number: CHIMNEY INFORMATION Masonry** {check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: w ; Model #: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections, I HAVE READ AND AGREE TO THE ABOVE: r PRINT NAME: Ul_ 11)A17 O DATE: SIGNATURE: DATE: G� Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 G, Peter Jensen 17 West Road South Glens Falls New York 1.2803 (518) 798 —3859 August 03,2016 To Whom It May Concern: A sump pump must be installed in the basement of the Thomas&Marcia Tyminski residence being constructed at 36 Meadowbrook Road, Queensbury.New York. The sump pump must discharge to daylight towards the rear of the property. Sincerely, G. Pete ensen e�k ED AC'yi L 026©�� �' OF 14 -4 EFILECOPY 2016 _J NORTH EAST BUILDING PERFORMANCE ADVISORS ...........................+.... yServing the Capital District, Saratoga and Adirondack Regions August 3, 2016 7 Rocky Ridge, Warrensburg,NY 12885 Roberts Builders Inc. 9768 Route 22 Middle Granville,NY 12849 RE: Blower Door Test for NYS Building Code Mr. William Roberts: In regards to the property of Ms. Marsha Tyminski; 36 Meadowbrook Road, Queensbury,NY 12804: ❖ I agree to perform a blower door test to ensure the home passes the current New York State Building Code for Air Changes per Hour @ 50 Pascal of less than or equal to 7 ACH/50. ❖ The US national average of air change rates, for existing homes, is between one and two per hour. Standard homes built today usually have air change rates from 0.5 to 1.0. Extremely tight new construction can achieve air change rates of 0.35 or less. Homes with an air change rate below 0.20, it is required to install and use a heat recovery mechanical ventilation system to bring in fresh outside air. The continuous ventilation system works to control the humidity and keep fresh air in the home for the occupants any time the house is occupied and all the windows and doors are shut. ❖ My credentials are as follows: A BPI Certified Building Analyst BPI Certified Envelope Specialist ➢ BPI Certified Heating Professional HERS Rater ❖ If you have any questions regarding my findings please feel free to contact me. ❖ The agreed upon cost of the Blower Door Test is $200.00. Sincerely, II f 'b Jack r&w ne/ Jack Towne 4UG 0 HERS Rater FILE CppY 1.888.472.2774 7 Rocky Ridge Road 4A Vatrano Drive Warrensburg,NY 12885 Albany,NY 12205 Phone (518)623.7016 Phone (518)350.2941 Fax (518)623.7015 Fax(518)694.0102 REScheck Software Version 4.6.1 Compliance Certificate Project BILL ROBERTS for THOMAS & MARCIA TYMINSKI Energy Code: 2010 New York Energy Conservation JUL 7 2016 Location: Warren County, New York Construction Type. Single-family Project Type: New Construction Conditioned Floor Area: 1,098 ft2 303,5-1-93 RC-000485-2016 Glazing Area 10% Tyminski, Marcia Climate Zone: 6 (7635 HDD) 36 Meadowbrook Road Permit Date: Permit Number: SFD w/FP 1.098 s.f., Garage 362 s.f. Construction Site: Owner/Agent: Designer/Contractor: 36 Meadowbrook Road Thomas&Marcia Tyminski G. Peter Jensen Queensbury, NY 12804 36 Meadowbrook Road 17 West Road 12804 South Glens Falls, NY 12803 (518) 798-3859 Compliance: 9.0%Better Than Code Maximum UA: 189 Your UA: 172 The%Better or worse Than Code Index reflects how close to compliance the house is based on code trade-of rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies lc�avity Con U-FactorUA. 'f :Aissembly or. -Ceiling 1:Raised or Energy Truss 1,098 38,0 0.0 0.025 27 Wall 1:Wood Frame, 16" o.c. 1,256 21.0 0.0 0.057 62 Window 1:Wood Frame:Double Pane with Low-E 108 0.310 33 Door 1: Solid 40 0.200 8 Door 2: Glass 20 0.310 6 Floor 1:All-Wood joist/Truss:Over unconditioned Space 1,098 30.0 0.0 0.033 36 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6.1 a mply with the mandatory requirements listed in the REScheck Inspection Checklist. -7 Zy GPETER DENS-EN Nar�Title 97 WEST ROAD - gnat e- Dates ,S")(3TH GLENS P,ALUS i Project Notes: W YORK 12f. Single family residence (518) Project Title: BILL ROBERTS for THOMAS & MARCIA TYMINSKI Report date: 07/26/16 Data filename: C;\Users\Peter\Documents\REScheck\Bill Roberts- Marcia Tyminski.rck Pagel of 6 REScheck Software Version 4.6.1 Inspection Checklist Energy Code: 2010 New York Energy Conservation Construction Code Requirements: 0.0%were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Re .ID 103.2 Construction drawings and ❑Complies [PR111 documentation sufficiently []Does Not J demonstrates energy code compliance for the building []Not Observable envelope. ❑Nat Applicable 103.2, Construction drawings and ocomplies 403.7 documentation sufficiently ❑Does Not [PR3)1 demonstrates energy code []Not Observable compliance for lighting and mechanical systems.Systems ❑Not Applicable serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: [ Complies [PR2)2 sized per ACCA Manual S based Btu/hr Btu []Does Not & on loads per ACCA Manual J or Cooling: Cooling: ❑Nat Observable other approved methods. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: BILL ROBERTS for THOMAS&MARCIA TYMIMSKI Report date: 07/26/16 Data filename: C:\Users\Peter\DocumentskREScheck\Bill Roberts-Marcia Tyminski.rck Page 2 of 6 2010 New York-- Foundation Inspection Complies? Comments/Assumptions Ener 303.2.1 Exposed foundation insulation ❑Complies [r011]2 protection. ODoes Not 1 ❑Not Observable • ❑Not Applicable 403.8 Snow melt controls. ❑Complies [FO12]2 ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(tier 3) Project Title: BILL ROBERTS for THOMAS&MARCIA TYMINSKI Report date: 0726/16 Data filename: C:lUsers\Peter\Documents\RESchecktBill Roberts-Marcia Tyminski.rck Page 3 of 6 Section Plans VerifiedField Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions &Re .10 402.4.4 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMAtCSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable • 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housingTnterior finish ❑Does Not and labeled to indicate&It;=2.0 dm leakage at 75 Pa. []Not Observable ❑Not Applicable 403.2,2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers,filter boxes,and []Does Not building cavities used as return ducts are sealed. ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not 4, below 55 2F are insulated to R-3. .� ❑Nat Observable ❑Not Applicable 403.4 Circulating service hot water R- R- ❑Complies [FR18]2 pipes are Insulated to R-2. []Does Not U []Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are []Complies [FR19]2 installed on all outdoor air DDoes Not intakes and exhausts. []Not Observable ❑Nat Applicable Additional Comments/Assumptions: 111 High Impact{Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: BILL ROBERTS for THOMAS&MARCIA TYMINSI<I Report date: 0726/16 Data filename: C:\Users\Peter\Documents\REScheck\Bill Roberts-Marcia Tyminski.rck Page 4 of 6 2010 New York Insulation Inspection Complies? Comments/Assumptions Energy 303.1 All installed insulation labeled or ❑Complies YN1312 installed R-values provided. ❑Does Not ❑Not Observable • ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact{Tier 3) Project Title: BILL ROBERTS for THOMAS&MARCIA TYM)NSKI Report date: 07/26/16 Data filename: C:\Users\Peter\Documents\REScheck\Bill Roberts-Marcia Tyminski.rck Page 5 of 6 Section Plans VerifiPedleld Verified # Final inspection Provisions Value Value Complies? CommentslAssumptions &Re .ID 402.4.2, Building envelope tightness ACH 50= ACH 50= ❑Complies 402.4.2.1 verified by blower door test result ❑Does Not [FI1711 of&lt;7 ACH at 50 Pa.This ❑Not Observable requirement may instead be met via visual inspection,in which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Duct tightness via post cfm cfm ❑Complies [F1411 construction with maximum ❑Does Not 411 leakage of 8 cfm to outdoors,or 12 cfm across systems.For ❑Nat Observable rough-in tests,verification may ❑Not Applicable need to occur during Framing Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats ❑Complies [F1912 installed on forced air furnaces. ❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F11012 on heat pumps. ❑Does Not []Not Observable ❑Not Applicable 403.4 Circulating service hot water ❑Complies [Fllip systems have automatic or ❑Does Not accessible manual controls. []Not Observable ONot Applicable 401.3 Compliance certificate posted. ❑Complies [F1712 ❑Does Not 4 []Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not equipment have been provided. []Not Observable '❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low impact(Tier 3) Project Title: BILL ROBERTS for THOMAS&MARCIA TYMINSKI Report date: 07/26/16 Data filename:C:\Users\Peter\Documents\REScheck\Bili Roberts-Marcia Tyminski.rck Page 6 of 6 2010 New York (Energy Conservation Construction Cocke Energy Efficiency Certificate Rati f RNalue Above-Grade Wall 21.00 Below-{Grade Wall 0.00 Floor 30.00 Ceiling 1 Roof 38.40 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.31 Door 0.20 Heating&Cooling Equipment Efficiency Heating Svstem: Cooling System: Water Heater: Name: Date: Comments WR4DOW SMEDU.E Type Call number Ada Gloss Yew Ama Si c $ of} '304 !!, 31 73 Sr 70 -3 7 4 3.2 2,e Fi vi O N N LM fn 00 Q rg ces ac ca Y ° rn � •� a a LL Ln . S o Lj- CM JUL 2 7 2016 LIGHT & VENTILATION SCHEDULE Pnea:- St LL RoP56RTs CD2 T�DA'�PA,S ti2AN3ew4 rymi vsK) Plan: Poom vex EK Code Actual Code Actual Area Size Bedroom 142.7 lI,42 ,?.>�,l02 •7/ t 144 244 Bin 'W2 /07'" 8.(o t t 1.31 4,36S' 5,7-3 �6-)7o aF ifet Bedroom Bedroom Bedroom Best DiWaB ROM Living Room Great 47o.3t 37. x"2.5 j /S•�i 2$ 1(a�!( 3 S- 4, Family Room Den A