Loading...
2013-128 TOWN OF QUEENSBURY *ors 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20130128 Date Issued: Monday, August 11, 2014 This is to certify that work requested to be done as shown by Permit Number P20130128 has been completed. Tax Map Number: 523400-239-015-0001-008-000-0000 Location: 25 WILD TURKEY Ln Owner: PAUL & BECKY KASSELMAN Applicant: PAUL KASSELMAN REVOCABLE TRUST This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the Q.7; 217) 4property owner of the responsibility for compliance with Site Plan, ./ fr Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY `ow 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: P20130128 Application Number. A20130128 Tax Map No: 523400-239-015-0001-008-000-0000 Permission is hereby granted to: PAUL KASSELMAN REVOCABLE TRUST For property located at 25 WILD TURKEY Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PAUL KASSELMAN REVOCABLE Septic Alteration Residential P& B KASSELMAN Total Value 237 ELM NE P.O. BOX 87 DELMAR,NY 12054 Contractor or Builder's Name/Address Electrical Inspection Agency MCNALLY EXCAVATION 518-251-5652 203 WEST Rd OLMSTEDVILLE NY 12857-0000 Plans&Specifications 2013-128 Res. Septic Alteration $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,April 23,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Q - 'sbury; Tuesd y,April 23,2013 SIGNED BY for the Town of Queensbury. Director of Building& Co:e ement OFFICE USE ONLY TAX MAP NO.41 39j5 1 PERMIT NO. —L�4AUPERMIT FEE 4-1P°D OR G S 2013 ` APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. M OWNER:�7 U IAA 5$e�in/4y� INSTALLER:&APO1, nn l � LX(' L}Ud1TIQ>N ADDRESS: 237 FL O".NE ?Oil, 57 piaartri.o ADDRESS: 203 W Q T AO QLmaTt Q lie NY/22.52 NY 12DS4 / 4`j PHONE NOS•c 'MN )143ct- 21C°6 PHONE NOS.C.c/8, ZS) - 242 ls LOCATION OF INSTALLATION: Z G p 1t,pTU?AKt,,r La I\I C Oo Zeros%u Zi-( YEAR BUILT NO.OF X COMPUTATION= RESIDENCE INFORMATION: BEDROOMS = TOTAL DAILY FLOW 1980 or older X 150 gallon per bedroom = GARBAGE GRINDER 1981 -1991 INSTALLED? rUb X 130 gallon per bedroom = 92-present X 110 gallon per bedroom = SPA OR HOT TUB 550 INSTALLED? 41.16 PARCEL INFORMATION: ✓ TOPOGRAPHY: Flat rolling Steep slope %Slope 13A2'5 ✓ SOIL NATURE: Sand ✓ Loam Clay Other ✓ GROUNDWATER: At what depth? MP ✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth? 3b'1 ✓ DOMESTIC WATER SUPLY: Municipal Well ✓ (If well: Water supply from any septic system absorption is ) » ft.) if PERCOLATION TEST: Rate is ) '' Vm'N per minute per inch. (Test to be co pleted by a licensed professional engineer or architect.) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: bscp GALLON (MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ❑ ABSORPTION FIELD (WITH NO. 2 STONE) Total length ft. Each trench X ❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size? ErALTERNATIVE SYSTEM Bed or other type? IP oQA Lo ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. own of Queensbury Building &Code Enforcement Office No. (518) 761r8256 Septic Inspection Report Inspection request received: J , Name: f(G) g S'aA\ A Inspected on: - Location: oZ S t ut 1ct—rt r it P y Arrive: .( �l> `pn /p.m. Permit No.: /3 —) g Inspector's Initials: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft Well separation distance ft. Other wells: ft. Well Casing Length 50'+/- Y N ' N/A [150'to well required if NO] Absorption Field: Total lengt Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size t x Ppne Size:Piping Size Type V Y,64 2+/ 9 Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y N End Cap _ N Inlet/Outlet Pipes&Bathes Y N Manholes 12"or less below grade Y N [provide extension collar if Yes] Y Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N ETU Maintenance Contract provided Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear S stem Use Stat : [Approve. pproved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report RR DatelTime 07122/2014 1135 P.001 p. 1 Bret W. Winchip Engineering P.C. PO Box 116, 6272 State Route 9, Chestertown,New York 12817. • Phone: (518) 494-2555 Fax: (518) 494-2566 May 22nd, 2013 Job.No.: 12029W Mr. Andy McNally McNally Excavating 203 West Road Olmstedville, NY 12857 Re: Kassehnan Property 25 Wild Turkey Lane Queensbury,NY 12804 • Dear Mr. McNally, This letter is to inform you that the septic system at the above referenced property was inspected by my office on April 16th,2013. The construction of the system was in general accordance with the approved plans. Based on a field measurement the closest point of the system is approximately 165'± from Lake George. If you have any questions or need any further assistance, do not hesitate to contact me. Sincerely, Bret W. Winchip,NYS PE#083076 Cc: Mr. Doug McCaIl l F Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: // 3 Queensbury Building &Code Enforcement Arrive: am/pm Depaam/pm 742 Bay Rd., Queensbury, NY 12804 Inspectors Initials: iep.9 V- NAME: Yt S�(f,"-, a�rJ PERMIT NO.: 3 s LOCATION: as tui to—142 V-1 /LN. INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand / Loam/Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance f . Other wells: ft. Well Casing Length 50'+ / - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. L----:FOVAr#L° Size ofStone N Seepage Pits: Number , Size: x _ Stone Size: Piping Size Type Building to tank 1 Tank to Distribution Box w Cjj "-"` " ' Distribution Box to Feld/ Pit Opening Sealed: —Y—N End Cap Y— N Inlet/Outlet Pipes&Baffles Y— N vCIZA 'c ie Manholes 12"or less below grade —Y—N [provide extension collar if Yes] _Y—N �- 4-34-407--+A.— Location/Separations Foundation to tank R ,. � Foundation to absorption ft. � (t (/M t�` 6//—r�' Z, Separation of Pits ft. , s� � Conforms as per Plot Plan —Y N �L Qyc. vPC5 lZ .. 2012- 2 Engineer Report and As-Built —Y N ETU Maintenance Contract Y N provided — — Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear 5 em Use Sta . App a Appro and needs to be re-inspected, please call the Building &Codes Office Disap L:\Pam Whiling\2010\Building Codes Forms\Irspection Fom,s\septic mon Report_03 2910.doc W adnes *-44 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: J:30 am/pr� ,Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: ¶4Q'!/ NAME: Qb,,(, PERMIT NO.: / a—/n, g LOCATION: 4.<5 W I %d u rk e,r3 k h INSPECT ON: 1.1— ati—!3 RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y_N_N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number _ Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box I J Distribution Box to Field/ Pit Opening Sealed: _Y_N End Cap Y_N / Inlet/Outlet Pipes&Baffles Y N / 4r4 Mh[provide 112e"orlesCollbelow rigrade TY_N 014- 4 &idn `f r'r, � Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan _Y_N Engineer Report and As-Built _Y_ N ETU Maintenance Contract _Y_ N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\&iilding Codes FormsWespectlon Fonns\Septic Inspection Report_03 29 10.doc LAKE GEORGE PROPOSED 4 PVC SDR 35 HOUSE SEWER ° \ 1/4" PER FOOT MINIMUM SLOPE \� 0 APPROXIMATE LOCATION EXISTING WASTEWATER, PUMP SEPTAGE AND REMOVE FROM SITE OR IF EXISTING TANKS ARE IN SOUND CONDITION, FREE OF LEAKS AND ARE EQUAL TO OR GREATER THAN REQUIRED CAPACITIES, THEY MAY BE REUSED_ REQUIRED CAPACITY FOR SEPTIC TANK = 2000 GALLON 1 REQUIRED CAPACITY FOR PUMP CHAMBER = 1500 GALLON PROPOSED 2000 GALLON PRECAST CONCRETE SEPTIC TANK PROPOSED 4" PVC SDR 35 EFFLUENT SEWER — \ 1/8" PER FOOT MINIMUM SLOPE PROPOSED 1500 GALLON PRECAST CONCRETE 1 \ \ EFFLUENT PUMP CHAMBER EXISTING 5 BEDROOM HOUSE PROPOSED 2" PVC SCH 40 FORCE MAIN (OR SIMILAR 100 PSI MINIMUM RATED) PROPOSED 6" PVC SCH 40 SLEEVE UNDER DRIVE f \ _ _ _ _ \ EXISTING WELL EXISTING ASPHALT DRIVE / i E/i '\ TO BE ABANDONED 6►�471_9 WNW TH #1 TANK 0" - 6" BROWN SANDY TOPSOIL WELL 6"- 20" RED BROWN SAND, SOME SILT, TRACE OF GRAVEL 20" - 32" BROWN SAND, SOME SILT, TRACE OF GRAVEL 32" BEDROCK 370 32" SEASONAL HIGH GROUND WATER 0 PERCOLATION @ 16" (ADJACENT TO TEST HOLE) - I" / 4 MINUTES TH #2 0" - 6" BROWN SANDY TOPSOIL 6"- 22" RED BROWN SAND, SOME SILT, TRACE OF GRAVEL 22" - 32" BROWN SAND, SOME SILT, TRACE OF GRAVEL 32" BEDROCK 364 32" SEASONAL HIGH GROUND WATER PERCOLATION @ 16" (ADJACENT. TO TEST HOLE) - I" / 4 MINUTES TH #3 0" - 6" BROWN SANDY TOPSOIL 6"- 20" RED BROWN SAND, SOME SILT, TRACE OF GRAVEL 20" - 32" BROWN SAND, SOME SILT, TRACE OF GRAVEL 32" BEDROCK 1 32" SEASONAL HIGH GROUND WATER X PERCOLATION @ 16" (ADJACENT TO TEST HOLE) - I" / 4 MINUTES �(r — /NM14 72B ti__ ` 40� z�— 100' FROM WELL �36GT PROPOSED PRESSURE TREATED RETAINING WALL OTHIS NEIGHBOR'S WATEP. SUPPLY IS A LAKE INTAKE l� \ 200' FROM MEAN HIGH DIRECT RUNOFF AROUND SYSTEM WATER OF LAKE GEORGE A`a DEPICTED ON SITE PLAN \ ORIGINAL GRADE i 3 B �1 \ V II \ } 0 100`+ TO 372 � �� � } 1 �• NEIGHBOR' 370 ` \TH1 a 0 `.. PROPOSED TANK SEPARATION REQUIREMENTS 370 TANK PROPERTY LINE BUILDING WELL SEPTIC TANK 10' MIN 10' MIN 50' MIN PUMP -CHAMBER 10' -MIN— — 10' -MIN 50 MIN 368 366 �. ,1 I 364 \ 1 \ \ \ \ \ \ 362 360 o \ \` \`\\\IiaO,M1�[MUM\ \\\\\\}\}\ \ \ GRADE TO DIRECT RUNOFF AROUND \ \ \ \ \ \\ \ \ SYSTEM AS SHOWN PROPOSED PURAFLO WASTEWATER ABSORPTION BED �\ \ \ \ `�\ \ \\ \ \ 00\0(p 5 CHAMBERS - 36'-3" X 16' = 580 SFIm f �\ 1�115'IMAINIMU4 I I I I I I I 11 I III I I 1 l l\01 I IIII 1\\ I I l i I I i MI�IIMUI°11 372 Q3 PROPOSED NEW WELL LOCATION RELEASED FOR APPROVAL 0 ADDED NOTES ABOUT DISTANCES TO NEIGHBORING WELLS t ADDED NOTE ABOUT EXISTING -TANKS 0 ADDED PROPOSED WELL LOCATION NO. I DESCRIPTION REVISI❑NS AFTER FINAL GRADING TOPSOIL, FERTILIZE, SEED AND STRAW MULCH ALL DISTURBED NON -SURFACED 2/17/12 ZNM BWW 7\ 4/2/13 ZNM BWW Q 4/8/13 ZNM BWW I 4/18/13 ZNM BWW A A DATE DWN CHECKED NO Ay DESCRIPTION REVISIONS BEDROCK — N L•7 200' SETBACK FROM MEAN HIGH WATER PROPOSED GRADE RETAINING WALL STONE BED #2 CRUSHED STONE r— PURAFLO MODULE (TYPICAL) ORIGINAL GRADE DATE I DWN 3 PROPOSED GRADE STONE BED #2 CRUSHED STONE PURAFLO MODULE (TYPICAL) 0 I+) THE DESIGN PRESENTED IN THIS DRAWING IS ONLY FOR THE CONSTRUCTION WORK SHOWN. USE OF THIS DRAWING BY ANY OTHER ENTITY FOR ANY OTHER PURPOSE IS A VIOLATION OF APPLICABLE LAWS. C` ITC I I -N f- A -17 1 /-\I% I 370 f AROUND SYSTEM 368 SITE }PLAN! AS DEPICTED ON SITE PLAN 366 1" _, 30, ORIGINAL GRADE 372 364 362 370 360 f 0 AFTER FINAL GRADING TOPSOIL, FERTILIZE, SEED AND STRAW MULCH ALL DISTURBED NON -SURFACED 2/17/12 ZNM BWW 7\ 4/2/13 ZNM BWW Q 4/8/13 ZNM BWW I 4/18/13 ZNM BWW A A DATE DWN CHECKED NO Ay DESCRIPTION REVISIONS BEDROCK — N L•7 200' SETBACK FROM MEAN HIGH WATER PROPOSED GRADE RETAINING WALL STONE BED #2 CRUSHED STONE r— PURAFLO MODULE (TYPICAL) ORIGINAL GRADE DATE I DWN 3 PROPOSED GRADE STONE BED #2 CRUSHED STONE PURAFLO MODULE (TYPICAL) 0 I+) THE DESIGN PRESENTED IN THIS DRAWING IS ONLY FOR THE CONSTRUCTION WORK SHOWN. USE OF THIS DRAWING BY ANY OTHER ENTITY FOR ANY OTHER PURPOSE IS A VIOLATION OF APPLICABLE LAWS. C` ITC I I -N f- A -17 1 /-\I% I LOCATION MAP III = 1000'+ 200' SETBACK FROM MEAN HIGH WATER RETAINING WALL PROPOSED GRADE VSTONE BED #2PURAFLODMODOULE (TYPICAL) \ 372 370 368 3 .. 366 _.— 364 362 0 CD 0 0 SECTION '� " (� � SEPTIC i�OT PLAN o 0 360 FIELD C I I M Y 1. I HAVE SEEN OR OBSERVED ALL CES, ETC SUCH AS HOUSES, WELLS, TREES, FENCES, ETC TOWN OF QUE�'IJS,P" SHOWN ON THIS DOCUMENT. I HAVE PERSONALLY BUILDING Q '. Or r j r it = CJ w� _ MEASURF THE DISTANCE SET FORTH ON THIS DIAGRAM. Reviewed By. SAfURE - DATE Date: 1 Bret W. Minchip Engineering, P.C. P.O. Box 116, 6272 State Route 9 ~f Chestertown, New York 12817 Phone: (518),494-2555 Fax: (518) 494-.2566 PROJECT: SITE PLA N NOTE: ' KASSELMAN PROPERTY It is a violation of New York State Education Law �G Article 145 Section 7209 for any person, unless he is ,p,�TER N,.'yCD TOWN OF GUEENSBURY acting under the direction of a licensed professional engineer, to alter an item in any way. If an: item 1 bearing the seal of an engineer is altered, the altering ` engineer shall affix to the item his seat and the_ no notation "altered by" followed by his signature and the n rU*��d % THIS 'DRAWING IS THE PROPERTY OF scAtE 1" 30' _ date of such alteration, and a specific description of r�i o n �` BRET W. WINCHIP ENGINEERING, P.C. DWN. BY: ZNM DATE: 12%1712 the alteration. sF�fa�rS'��y�'y ALL DIMENSIONS AND INFORMATION IS CHWD BY: BWW DATE 12/17%12 TO BE VERIFIED BY THE CONTRACTOR PROJECT No. 12029W APPR'D. DATE: APR 18 2013 BEFORE CONSTRUCTION. SHEET Na. 1 OF 2 REV. a DIRECT RUNOFF f AROUND SYSTEM AS DEPICTED ON SITE PLAN ORIGINAL GRADE 372 372 370 370 368 368 366 366 — 364 364 — 362 362 } Y �. BEDOC. " R .=yam 360 360. X LOCATION MAP III = 1000'+ 200' SETBACK FROM MEAN HIGH WATER RETAINING WALL PROPOSED GRADE VSTONE BED #2PURAFLODMODOULE (TYPICAL) \ 372 370 368 3 .. 366 _.— 364 362 0 CD 0 0 SECTION '� " (� � SEPTIC i�OT PLAN o 0 360 FIELD C I I M Y 1. I HAVE SEEN OR OBSERVED ALL CES, ETC SUCH AS HOUSES, WELLS, TREES, FENCES, ETC TOWN OF QUE�'IJS,P" SHOWN ON THIS DOCUMENT. I HAVE PERSONALLY BUILDING Q '. Or r j r it = CJ w� _ MEASURF THE DISTANCE SET FORTH ON THIS DIAGRAM. Reviewed By. SAfURE - DATE Date: 1 Bret W. Minchip Engineering, P.C. P.O. Box 116, 6272 State Route 9 ~f Chestertown, New York 12817 Phone: (518),494-2555 Fax: (518) 494-.2566 PROJECT: SITE PLA N NOTE: ' KASSELMAN PROPERTY It is a violation of New York State Education Law �G Article 145 Section 7209 for any person, unless he is ,p,�TER N,.'yCD TOWN OF GUEENSBURY acting under the direction of a licensed professional engineer, to alter an item in any way. If an: item 1 bearing the seal of an engineer is altered, the altering ` engineer shall affix to the item his seat and the_ no notation "altered by" followed by his signature and the n rU*��d % THIS 'DRAWING IS THE PROPERTY OF scAtE 1" 30' _ date of such alteration, and a specific description of r�i o n �` BRET W. WINCHIP ENGINEERING, P.C. DWN. BY: ZNM DATE: 12%1712 the alteration. sF�fa�rS'��y�'y ALL DIMENSIONS AND INFORMATION IS CHWD BY: BWW DATE 12/17%12 TO BE VERIFIED BY THE CONTRACTOR PROJECT No. 12029W APPR'D. DATE: APR 18 2013 BEFORE CONSTRUCTION. SHEET Na. 1 OF 2 REV. a 66- 1 59"± 2" PVC SCH40 CAP SAMPLING CHAMBER 53-1/2" --i 18" 1--- 36'-4" FROM EFFLUENT PUMP -- ------------------------------------------------------------ - _ -- PUROFLO MODULE PLAN ly SCALE: 1/4" = 1'-0" END CAP AFTER LAST CONNECTION EFF. DIST. ^'^"'^ i 7'-1" EFF. DIST. PIPING 7 WEEP HOLE t LONGITUDINAL VIEW TO FORCE MAIN L PURAFLO MODULE DETAIL Scale: 1/4" = V-0" ARELEASED FOR APPROVAL D ADDED WELL DETAIL 1 Q A NO. nnnnni tnin CHAMBER 59"± FEED IN MANIFOLD' 2" PVC SCH40 (TYPICAL) 12"± 6" OF SAND, PEA GRAVEL OR 3/4 TO 1-112" AGGREGATE T— STONE PAD AREA (SEE SECTION) 2" PVC SCH40 CAP LOCATION MARKER /-FINISHED GRADE WATERTIGHT SEAL ALL COVERS, JOINTS AND PENETRATIONS INLET ;1 II I 11 _�—PROVIDE 24" ACCESS TO GRADE. SEPTIC NOTES & OPERATION GUIDELINES: FOR INSPECTION OF FILTER 1) WATER SUPPLY TO THE RESIDENTIAL STRUCTURES WILL BE EQUIPED WITH A WATER INTERLOCK TO FFLUENT FILTER PREVENT LOADING OF SEPTIC SYSTEM AND PUMP STATION DURING POWER OUTAGES. UNITARY TEE 2) SYSTEM DESIGN BASED ON (5) BEDROOMS, 110 GAL./DAY/BEDROOM. CLIENT SHOULD CONSIDER THE INSTALLATION OF WATER CONSERVING FIXTURES TO INCREASE LIFE OF SYSTEM. AULKED JOINT (TYPICAL) 3) NO GARBAGE GRINDER SHALL BE PLACED IN SERVICE. 4) INFILTRATION PAD DESIGN BASED ON PURAFLO DESIGN REFERENCE MATERIAL 6" MIN WALL THICKNESS FOR 5) EFFLUENT FILTER SHALL BE INSPECTED AND CLEANED REGULARLY PER MANUFACTURER'S MAINTENANCE POURED IN PLACE INSTRUCTIONS'. FAILURE TO DO SO COULD RESULT IN FAILURE OF THE BIOFILTER SYSTEM. PEAT MEDIA DESIGNED FOR MINIMUM 15 YEAR EXPECTED LIFE. 6) SEPTIC TANK SHALL BE INSPECTED YEARLY TO ASCERTAIN SLUDGE AND SCUM LEVELS. TANKS SHALL BE PUMPED WHEN SLUDGE LEVELS REACH DEPTH OF 10" BELOW THE BOTTOM OF THE OUTLET BAFFLE OR PRECAST OR POURED FILTER BOTTOM OR WHEN THE SCUM LEVEL IS WITHIN 3" OF THE BOTTOM OF THE OUTLET BAFFLE OR CONCRETE SEPTIC TANK FILTER BOTTOM. TANKS SHALL BE PUMPED EVERY THREE YEARS AS REQUIRED REGARDLESS OF SLUDGE OR SCUM LEVELS. 'OUTLET 7) SEPTIC TANK SIZED PER NEW YORK STATE APPROVED CRITERIA FROM TABLE 3, APPENDIX 75-A, WASTEWATER TREATMENT STANDARDS, INDIVIDUAL HOUSEHOLD SYSTEMS. 8) OWNER OR OWNERS AGENT SHALL APPLY TO TOWN OF QUEFNSBU Y CONCRETE SEPTIC TANK PURAFLO DESIGN DATA INSTALL PURAFLO INSTALLATION NOTES: COVER DESIGN PERCOLATION RATE = 1-5 MINUTES/INCH* INSPECTION REQUIREMENTS. I. REFER TO'PURAFLO FILTRATION SYSTEMS PUMP CHARGED NON -CERTIFIED DEALER PRICING TO GRADE (EXTERNAL) NTS LIST FOR CONTRACTOR COST AND LIST OF SUPPLIED EQUIPMENT FROM PURAFLO. LISTED MANIFOLD DESIGN DAILY FLOW = 5 BEDROOMS X 110 GPD/BR NOTE: EQUIPMENT MUST BE MANUFACTURED BY PURAFLO. SUBSTITUTION OF EQUIPMENT SHALL VOID 9) IF ANY REVIEW AGENCY REQUIRES INSPECTION DESIGN DAILY FLOW = 550 GPD- SIGN OFF BY ENGINEER OF RECORD. SEPTIC SYSTEM DESIGN. GALLONS FOR 5 BEDROOMS DESIGN APPLICATION RATE = 0.95 GPD/SF RECORD 2. CONTRACTOR SHALL RECIEVE INSTALLATION SUPERVISION OF PURAFLO MODULES AND SET UP USE 1250 (PURAFLO DESIGN REFERENCE MATERIAL, NYS DOH APP. 75-A) ENGINEER OF RECORD SHALL NOT SIGN OFF OF PURAFLO SUPPLIED EQUIPMENT UNLESS THE CONTRACTOR IS A CERTIFIED PURAFLO USE 1000 GALLONS FOR 3 BEDROOMS OR LESS CONNECTION DETAIL INSTALLER. SUPERVISION SHALL BE PERFORMED BY A CERTIFIED REPRESENTATIVE FROM HIGH TIMER OVERRIDE EFFECTIVE LEACHING AREA REQUIRED = 550 GPD / 0.95 GPD/SF PUMP — — EMMONS PUMP & CONTROLS, INC., 453 NORTH PEARL STREET, ALBANY, NY 12204, OR CERTIFIED "SJE RHOMBUS" EFFECTIVE LEACHING AREA REQUIRED = 579 SF 20"' FACTORY REPRESENTATIVE. THE CONTRACTOR SHALL SCHEDULE THE INSTALLATION WITH THE BLOCK PUMP -- TIMER ENABLE TRU-UNION 2" PVC BALL CHECK FACTORY INSTALLATION SUPERVISOR IN A TIMELY MANOR. N2` MINIMUM .EFFECTIVE LEACHING AREA SUPPLIED = 36'-3" x 16'-0" = 580 SF Ns —6" GRAVEL 3. REPRESENTATIVE SHALL TEST AND AIDE IN ADJUSTMENT OF PURAFLO SYSTEM AT TIME OF NOTES *NOTE: FILL MATERIAL SHALL HAVE A STABILIZED PERCOLATION RATE SETUP. BETWEEN 3-5 MINUTES/INCH VERIFIED BY INSITU TEST AT BORROW PIT AND - SET ALARM 6" ABOVE "PUMP ON" AFTER PLACEMENT IN BED AREA - INSTALL POWER AND CONTROL WIRES TO CONTROLLER LOCATED IN HOUSE - USE 1500 GALLON SEPTIC TANK FOR PUMP CHAMBER - 8X8 P.T. LANDSCAPE TIMBER RETAINING WALL - PROVIDE "T" WITH GATE VALVE TO DRAIN (TIMBERS RATED FOR GROUND CONTACT) END VIEW TO PURCHASI�G PUMP(S) (TIMBERS SHALL BE SPIKED TOGETHER USING APP. TIMBER SPIKES @ 48" O.C. MAX) - PROVIDE FROST PROTECTIVE SOIL COVER OVER FORCE MAIN TO FORCE MAIN PURAFLO PEAT FIBER BIOFILTER (TYPICAL)(COLOR CODED AS SHOWN) 66- 1 59"± 2" PVC SCH40 CAP SAMPLING CHAMBER 53-1/2" --i 18" 1--- 36'-4" FROM EFFLUENT PUMP -- ------------------------------------------------------------ - _ -- PUROFLO MODULE PLAN ly SCALE: 1/4" = 1'-0" END CAP AFTER LAST CONNECTION EFF. DIST. ^'^"'^ i 7'-1" EFF. DIST. PIPING 7 WEEP HOLE t LONGITUDINAL VIEW TO FORCE MAIN L PURAFLO MODULE DETAIL Scale: 1/4" = V-0" ARELEASED FOR APPROVAL D ADDED WELL DETAIL 1 Q A NO. nnnnni tnin CHAMBER 59"± FEED IN MANIFOLD' 2" PVC SCH40 (TYPICAL) 12"± 6" OF SAND, PEA GRAVEL OR 3/4 TO 1-112" AGGREGATE T— STONE PAD AREA (SEE SECTION) 2" PVC SCH40 CAP LOCATION MARKER /-FINISHED GRADE WATERTIGHT SEAL ALL COVERS, JOINTS AND PENETRATIONS INLET ;1 II I 11 _�—PROVIDE 24" ACCESS TO GRADE. SEPTIC NOTES & OPERATION GUIDELINES: FOR INSPECTION OF FILTER 1) WATER SUPPLY TO THE RESIDENTIAL STRUCTURES WILL BE EQUIPED WITH A WATER INTERLOCK TO FFLUENT FILTER PREVENT LOADING OF SEPTIC SYSTEM AND PUMP STATION DURING POWER OUTAGES. UNITARY TEE 2) SYSTEM DESIGN BASED ON (5) BEDROOMS, 110 GAL./DAY/BEDROOM. CLIENT SHOULD CONSIDER THE INSTALLATION OF WATER CONSERVING FIXTURES TO INCREASE LIFE OF SYSTEM. AULKED JOINT (TYPICAL) 3) NO GARBAGE GRINDER SHALL BE PLACED IN SERVICE. 4) INFILTRATION PAD DESIGN BASED ON PURAFLO DESIGN REFERENCE MATERIAL 6" MIN WALL THICKNESS FOR 5) EFFLUENT FILTER SHALL BE INSPECTED AND CLEANED REGULARLY PER MANUFACTURER'S MAINTENANCE POURED IN PLACE INSTRUCTIONS'. FAILURE TO DO SO COULD RESULT IN FAILURE OF THE BIOFILTER SYSTEM. PEAT MEDIA DESIGNED FOR MINIMUM 15 YEAR EXPECTED LIFE. 6) SEPTIC TANK SHALL BE INSPECTED YEARLY TO ASCERTAIN SLUDGE AND SCUM LEVELS. TANKS SHALL BE PUMPED WHEN SLUDGE LEVELS REACH DEPTH OF 10" BELOW THE BOTTOM OF THE OUTLET BAFFLE OR PRECAST OR POURED FILTER BOTTOM OR WHEN THE SCUM LEVEL IS WITHIN 3" OF THE BOTTOM OF THE OUTLET BAFFLE OR CONCRETE SEPTIC TANK FILTER BOTTOM. TANKS SHALL BE PUMPED EVERY THREE YEARS AS REQUIRED REGARDLESS OF SLUDGE OR SCUM LEVELS. 'OUTLET 7) SEPTIC TANK SIZED PER NEW YORK STATE APPROVED CRITERIA FROM TABLE 3, APPENDIX 75-A, WASTEWATER TREATMENT STANDARDS, INDIVIDUAL HOUSEHOLD SYSTEMS. 8) OWNER OR OWNERS AGENT SHALL APPLY TO TOWN OF QUEFNSBU Y CONCRETE SEPTIC TANK HAVE JURISDICTION, FOR SEPTIC PERMIT TO INSTALL R AND ANY OTHER ENTITY THAT MAY SYSTEM AND SHALL BE RESPONSIBLE TO MEET ALL COVER 2' 0 EXTENSION INSPECTION REQUIREMENTS. /18/13 TO GRADE (EXTERNAL) NTS HYDROMATIC �SHEFI00 MANIFOLD ' NOTE: CONNECTION PIECE 9) IF ANY REVIEW AGENCY REQUIRES INSPECTION AND SIGN OFF BY ENGINEER OF RECORD. SEPTIC USE 1500 GALLONS FOR 5 BEDROOMS CONTRACTOR SHALL CONTACT ENGINEER OF RECORD 1N A TIMELY MANNER TO SCHEDULE INSPECTIONS. USE 1250 GALLONS FOR 4 -BEDROOMS ENGINEER OF RECORD SHALL NOT SIGN OFF ON SYSTEMS WHICH ARE INSTALLED WITHOUT INSPECTION. USE 1000 GALLONS FOR 3 BEDROOMS OR LESS CONNECTION DETAIL UNION HIGH TIMER OVERRIDE NOTE: PUMP — — 2 ALARM FLOAT "SJE RHOMBUS" REVISIONS - INSTALL ZABEL A300-8X18VC WASTEWATER EFFLUENT FILTER IN OUTLET TEE - GARBAGE GRINDER SHALL BE CONSIDERED EQUIVALENT TO AN ADDITIONAL BEDROOM FOR SIZING SEPTIC TANK.. AN OUTLET GAS DEFLECTION BAFFLE AND A TWO COMPARTMENT SEPTIC TANK IS REQUIRED WHEN A GARBAGE GRINDER IS INSTALLED - INSTALL TEE IN TANK INLET AND OUTLET 16",AND 18' BELOW LIQUID LEVEL RESPECTIVELY DESCRIPTION REVISIONS EFFLUENT PUMP DETAIL (N. T. S.) 1/17/12 "T" WITH VALVE AND DRAIN MODEL # COVER 2' 0 EXTENSION t =� _.._ a /18/13 TO GRADE (EXTERNAL) ' HYDROMATIC �SHEFI00 MANIFOLD ' JUNCTION BOX, INSTALL CONTROL CONNECTION PIECE `e PANEL IN HOME "SIE RHOMBUS" DATE DRILL 1/4"0 WEEP HOLE TO DRAIN 2" FORCE MAIN INLET FORCE MAIN EVERY CYCLE "SJE RHOMBUS" �, PRECAST CONCRETE SEPTIC TANK GATE VALVE CHECK VALVE CONNECTION DETAIL UNION HIGH TIMER OVERRIDE CHE YKED PUMP — — 2 ALARM FLOAT "SJE RHOMBUS" REVISIONS 20"' CHECK VALVE BLOCK PUMP -- TIMER ENABLE TRU-UNION 2" PVC BALL CHECK AS REQUIRED N2` MINIMUM UBVE Ns —6" GRAVEL 4,-6„ NOTES - SEAL ALL OPENINGS WATERTIGHT EFF. DIST. - SET ALARM 6" ABOVE "PUMP ON" PIPING - INSTALL POWER AND CONTROL WIRES TO CONTROLLER LOCATED IN HOUSE - USE 1500 GALLON SEPTIC TANK FOR PUMP CHAMBER - WITH NO BAFFLES TT WEEP HOLE - PROVIDE "T" WITH GATE VALVE TO DRAIN - CONTRACTOR SHALL VERIFY EXISTING ELECTRICAL SERVICE PRIOR END VIEW TO PURCHASI�G PUMP(S) - PROVIDE FROST PROTECTIVE SOIL COVER OVER FORCE MAIN TO FORCE MAIN DESCRIPTION REVISIONS EFFLUENT PUMP DETAIL (N. T. S.) 1/17/12 ZNM BWW MODEL # COMMENTS t =� _.._ a /18/13 ZNM BWW `F `' YDROMATIC" H HYDROMATIC �SHEFI00 50 GPM AT 55 FT. TDH. SET UP FOR I EXTERNAL CONTROLS, NEMA 4X BOX CONTROL/ALARM PANEL "SIE RHOMBUS" DATE DWN EZS PANEL - IIW114HIJ3A6A8AC10E15AI7H18A FLOAT SWITCH "SJE RHOMBUS" "SIGNAL MASTER" N.Q. SWITCH WITH EXTERNAL WEIGHT, � 3 REQUIRED DATE DWN CHE YKED 4 FLOAT BRACKET WITH MOUNT DEVICE .DESCRIPTION "SJE RHOMBUS" REVISIONS TO HOUSE 00' MIN) A 2" ANNULUS OF NEAT CEMENT OR BENTONITE GROUT IS REQUIRED. REFER TO CITED PUBLICATION FOR MINIMUM REQUIRED DEPTH OF GROUT WATER SIPPLY WELLS SHALL BE CONSTRU TED IN ACCORDANCE WITH APPENDIX15-B TITLED "STANDARDS FOR WATER WELLS" 1-11V1511tU GRADE PITLESS ADAPTER SEAL CASING TO BEDROCK e NOTE: ENGINEER ASSUMES NO RESPONSIBILITY FOR SUBSTITUTIONS TO THE ABOVE EQUIPMENT WITHOUT PRIOR APPROVAL. SUBMERSIBLE PUMP ; 11 PUMP TANK EQUIPMENT SPECIFICATIONS ITEM MANUFACTURER MODEL # COMMENTS t =� _.._ a _• z �',- ,t I HP, ,230V, 1 PHASE PUMP_ SHALL DELIVER 1 `EFFLUENT PUMP t a= - `F `' YDROMATIC" H HYDROMATIC �SHEFI00 50 GPM AT 55 FT. TDH. SET UP FOR I EXTERNAL CONTROLS, NEMA 4X BOX CONTROL/ALARM PANEL "SIE RHOMBUS" SIMPLEX CONTROL PANEL (TIMED DOSE), EZS PANEL - IIW114HIJ3A6A8AC10E15AI7H18A FLOAT SWITCH "SJE RHOMBUS" "SIGNAL MASTER" N.Q. SWITCH WITH EXTERNAL WEIGHT, 3 REQUIRED FLOAT SWITCH BRACKET "SJE RHOMBUS" 4FB 4 FLOAT BRACKET WITH MOUNT DEVICE JUNCTION BOX "SJE RHOMBUS" JB664-2H-5R8 NEMA 4X CHECK VALVE "FLOMATIC" 2134T TRU-UNION 2" PVC BALL CHECK UNION BALL VALVE "CAMBELL" UBVE 2" PVC, 150 PSI I a WELL DETAIL (N.T.S.) NOT:::: IF AQUIFER MATER ENTERS WATER WELL AT A DEPTH LESS THAN ret i n c h iEngineering, . C . 50' WELL SEPARATION DISTANCES TO CONTAMINATION SOURCES MUST BE P.O. Box 116, 6272 State Route 9 INC EASED BY 50%. Chestertown, New York 12817 Phone: (518) 494-2555 Fax: (518) 494-2566 PROJECT: SITE PLAN THE DESIGN PRESENTED IN THIS DRAWING IS ONLY NOTE: 0-a N, KASSELMAN PROPERTY FOR THE CONSTRUCTION WORK SHOWN. USE OF It is a -Violation of New York State Education Law � �� icti" TOWN OF QUEENSBURY THIS DRAWING BY ANY OTHER ENTITY FOR ANY Article under section 7209 for any person, unless he is / f.� ✓" O acting .under fhe direction of a licedsed professional p\i� OTHER PURPOSE IS A VIOLATION OF APPLICABLE engineer, to alter an item in any way.' If an item LAWS. bearing the seal of an engineer is altered, the altering ^ z-' .engineer shall ...affix ,.to the item his seal and the . ,— {ii-- '�. 'r SCALE.: AS NOTED "� THIS DRAWING IS THE PROPERTY OF notation altered by" followed by his signifure and the. rn .� date .of .such alteration, and a;. specific description. of`'J'�.'` �3;307n 5 BRET W. WINCHIP ENGINEERING, P.C. DWN. BY: ZNM DATE: 12/17/12 the alteration. 1.01, ww ALL DIMENSIONS AND ' INFORMATION IS CHWD BY: BWW DATE 12/17/12 l TO BE VERIFIED BY THE CONTRACTOR PROJECT NO. 12029W APPR'D. DATE: APR 18 7013 BEFORE CONSTRUCTION. SHEET NO. 2 OF 2 REV. d