2013-117 TOWN OF QUEENSBURY
•
742 Bay Road,Qucensbury, 12804-5902 (518) 761-8201
��� yQ r7�
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20130117 Date Issued: Wednesday, October 08, 2014
This is to certify that work requested to be done as shown by Permit Number P20130117
has been completed.
Location: 578 AVIATION Rd I-II #1
Tax Map Number: 523400-302-005-0001-092-011-0000
Owner: AVIATION MALL NEWCO LLC
Applicant: JC PENNEY- AVIATION MALL
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property ci)Jw4/1. /s`
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building& Code Enforcement
or Zoning Board of Appeals.
0.14 TOWN OF QUEENSBURY
`1 • 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20130117 Application Number: A20130II 7
Tax Map No: 523400-302-005-0001-092-011-0000
Permission is hereby granted to: JC PENNEY-AVIATION MALL
For property located at: 578 AVIATION Rd HI #1
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: AVIATION MALL NEWCO LLC
Commercial Alteration
4 CLINTON Sq Total value
SYRACUSE,NY 13202-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
RICH& GARDNER CONSTRUCTION
1433 ERIE BLVD. EAST
SYRACUSE.NY
Plans&Specifications
2013-117 JC Penney
Comm. alterations 11,876 sq st
$2,375.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,April 02, 201.1
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queen ury; ues i , , pril 02, 2013
SIGNED BY ' for the Town of Queensbury.
Director of Building&Code Enforcement
OFFICE USE ONLY
2 Q
TAX MAP NO.30c ,5_17 iaj j__---PERMIT NO. /- -
FEES: PERMIT RECREATIONENGINEERING APR 01 2013
---_--__--.--..._ �
(If applicable)
PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING
PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW
BEFORE ISSUANCE OF A VALIDrPERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: l[I S c4tQ/vt- OWNER: J C \,0w 1/1./17), Aj
ADDRESS: 2_06 I'1 S .6 (fyp Jt1 /32 ,ADDRESS: /'-�//A-11C4 i1 li.We•l1(
PHONE NOS[/ ) � /'7 6C0 PHONE NOS. (L✓"l Qi N1/
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: 6p-,c PHONE:3/SSS�V 1sZ ((
LOCATION OF PROPERTY: 4' fr(/v' )44, ( � j��
HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? YES 0 NO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z
APPLY TO YOUR z o O C oLi- co
O Q O
PROJECT Lir
O p •
J O = _
Z < < �- � NoCL 0
LL I- u CL 0:5
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL- / /1976
/ 6
/?'6
MERCANTILE y�(� %
FACTORY OR /
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL- NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: _ FUEL TYPE: pc AA
HEAT TYPE: Al I/ *HOW MANY FIREPLACE(S): /V/4 AND/OR WOODSTOVES(S):_�
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? /t//4
IS THIS A HISTORIC SITE? /
PROPOSED USE OF BUILDING OR ADDITION: (10)44il "/-0 1 /filketti
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? /
ARE THERE EASEMENTS ON PROPERTY? /1//s
"Hease complete a separate Appii.',at!,:n1 for'Fuel Burning At pliafncns&Chimneys' available in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes
or septic systems)
•
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Applicatio :
BUI nf'4G'&CODE: 'PPROVAL ZONING APPROVAL
I "
DAT: DATE
• QUESTIONS? CALL 761-8256 OR EMAIL
codes(a?queensbury.net
Office Use Only . VISIT OUR WEBSITE FOR MORE INFORMATION
www.queensbury.net
Operating Permit Issued: Yes No
Occupancy Type: Construction Classification:
Assembly Occupancy Limit: Special Conditions:
Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804
Town of Queensbury Building &Code Enforcement
Office No. (518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: 77E— YF Inspected on: \u _4 A
Location: A�\� 1n�� 1 11_1 Arrive: -;�i a.m. p.m.
Permit No.: \3-\ r( Inspector's Initials: r A
COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch/Step Risers 7"!Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36"(w)x 44"(I)1 Canopy or Equiv.
:////
Gas Valve Shut-off Exposed &Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap 1 Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%> 1000 sq.ft.
%Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage I Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond [Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification, if req.
As-built Septic System Layout Required or On File \
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler �
Building Access All Sides by 20'/Drivable Surface 20'wide p \
Special Inspections/Engineer or Architect Approval DT
Okay To Issue Temporary or Permanent C/O
Okay To Issue C/C
Commercial Final Inspection_11 27 12
Town of Queensbury Building &Code Enforcement
• Office No. (518) 761-8256
Commercial Final Inspection Report
Inspection request received:
Name: —)0_ pa.,AC..3 Inspected on: �+"
Location: 5 ! 3 &U,0.4- to GW Arrive: 'Z= ,..11111/ ; a.m. p.�
Permit No.: / 3"/i'/ Inspector's Initials: �Or
COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior!Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch I Step Risers 7"!Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 inch w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36"(w)x 44"(I)!Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay • —j "TV—k 13-6 C7 p j
Relief Valve, Heat Trap I Water Temperature 110 Degrees Maximum
Boiler!Furnace Enclosure 1 hour or Fire Extinguishing System �t
Fresh Air Supply for Occupancy/Ventilation Combustion A
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area ,,`}�f��
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%> 1000 sq.ft. `v
'/<Hour Corridor Doors&Closers (��
Firewalls I Fire Separation,2 Hour,3 Hour Complete 1 Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars I Sinks/Toilets 1 Mirrors
Handicapped Bath I Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp 1 Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan I Variance required
Final Survey, New Structure I Flood Plain certification, if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler
Building Access All Sides by 20'/Drivable Surface 20'wide
Special Inspections I Engineer or Architect Approval
Okay To Issue Temporary or Permanent C/O
Okay To Issue C/C
Commercial Final Inspection_11 2712
of Queensbury Building & Code Enforcement
Office No. (518)761-8256
Commercial Final inspection Report
Inspection request received:
Name: : e_. C�n S Inspected on: —3
Location: gj rl Arrive: i ri ap m.
Permit No.: 13 'I/ 17 Inspector's Initials: Mr,
COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior I Exterior Guardrails 42 inch Platform I Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch-38 inch I Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq.ft.
All Doos 36 inC-hew/Lever Handles I Panic Hardware,if required
xits At Grade Or atform 36"(w)x 44"(I)/Canopy or Equiv.
/ -
as Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap I Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 sq.ft.
'/a Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers I Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage!Shaft Sealed
Handicapped Bathroom Grab Bars I Sinks!Toilets I Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp!Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical I Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure!Flood Plain certification,if req.
As-built Septic System Layout Required or On File r
Building Number or Tenant Address on Building or Driveway 4" c_44)\__ _-__—‘ F
Water Fountain or Cooler , ` rr� ` ` �
Building Access All Sides by 20'!Drivable Surface 20'wide 1 \ ‘tiTJ \t E
Special Inspections/Engineer or Architect Approval / C=---- \ ,0 P5V-iiN
Okay To Issue Temporary or Permanent CIO �- -� -
Okay To Issue C/C WE_ 7V.--�
Commercial Final Inspection_!! 27 12
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: `- 7D a : 'apart: \'-17D arra�2
Date Inspection request received: Inspector's Initials: V .�
NAME: - ' 1(--- P� (�lc_'t,�� PE #: / 3 — if/
/
LOCATION: Pt\! y kik-ipi R I Mill DATES 9-Z1 — 117
TYPE OF STRUCTURE:
%/, '}/.7 . Comments:
G Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed!regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors ! P �Xt 1 t76 &v L P
ID
Every level: Every Bedroom:
Outside every bedroom area: V VV-0
_ M -1-74 N.....-c- 1 C
Inter Connected: Battery backup: �
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents (06C?-E-Ve__ \�L_
Bathroom Fans,if no window
Plumbing fixtures Y3O1 X17 MpLe:T-
Foundation insulation to floor!Sticker on Panel
Duct work sealed properly/Blower Door Test Certification 1 17.. \y3tj 6C
Floor truss,draft stopping finished basement 1,000 sq.ft. / j7
Emergency egress below grade //
Gas Furnace shut-off within 30 feet or within line of site i
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical; Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker / -
Site Plan /Variance required
Flood Plain Certification, if required /
Okay to issue C/C or C 1 0[Temporary/Permanent] /
L:\Building&Codes Forms\Building&Codesllnspection Forms\Residential Fina(Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08; Revised 12122/10, Revised 04/13/11
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection requ re =` d•
Queensbury Building &Code Enforcement Arrive: \ 5t am j I -part: 'Z4 i1) am/
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: � � P P S PER IT
LOCATION: J ') ' 1k) c Rd. DA g:.
COMMENTS:
Y N NA
Chimney/13"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish 1 Grade Complete 6" in 10'or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior I Exterior Ballisters 4 in. Spacing Platform I Decks
Stair Handrail 34 in.-38 in. /Step Risers 7"I Treads 11"
Vestibules For Exit doors>3000.N.ft
All Doors 36 in.wlLever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44'(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay604
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum F IoM L c D
Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion Fk-1 ,c,
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site T •
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 %doors ��
> 10%>1000 sq.ft.
' Hour Corridor Doors&Closers W\V a‘N
Firewalls l Fire Separation, 2 Hour, 3 Hour Complete I Fire
Dampers I Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars I Sinks/Toilets
Handicapped Bath I Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond [Both
_sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure I Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access All Sides by 20'/Driveable Surface 20'wide
Okay To Issue Temp. or Permanent CIO
Okay To Issue C/C
L:\Building&Codes Forms\Building&CodesUnspection Forms\Commercial Final Inspection Report.doc Revised January 7,2008
M
Inspection Form
Town of Queensbury Fire Marshal Periodic Inspection Date:iJ /3 Time:
742 Bay Road,Queensbury NY 12804 o Re-Inspection J) i
518 761 8206/518 761 8205 o CO Inspection Permit#: / 3l , i
Fir Marshals Representative if
MJ Palmer Business Name: J L- F 2 \AC1
Location: -S r) 3 ANv'-t?.2r-',x. u Pal
GK Stillman Contact: bnx L
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014& FC1029 NOTES
Exit Enclosure FC 1020& FC1029
Exit Discharge FC 1024& FC1029
Locks and latches FC1008& FC1029.2
Sign:Normal FC 1011 &FC1029
Sign:backup FC 1011.5.3& FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11 __ _
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906 J
EVAC Plan FC 404.6 - Milir,
TRUSS ID SIGNAGE FC 505.3 v
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8 �1�%
Exterior FC 1006.3i i �G-�+
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1 0,
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3 -
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6(R1 &R2) -
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
__Exterior storage Fc 315.3 - REINSPECTION DUE APPROXIMATELY
Vacant Buildings FC 311
21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual ----mSprinkler FDC Fire Marshal klspecli tir,
Kitchen Suppression Semi Annual CO may be issued Y wl
Fuel Island Suppression Semi Annual MStlll�ig&Cod's oval
Hood Cleaning 3-6 -Annual
Knox Box:installed/checked FC506 /,UG ;" 4. .1'
l -� -
Operating Permit, if required will be issued after _____ -----
Completion of Inspection fire Marshal
To
�._..__. Town_____°f Clueensburv______. _
Commercial Final Inspection Report )(/'-7
Office No.: (518) 761-8256 Date Inspection •• e e / ed: c` ( (,(-5Queensbury Building &Code Enforcement Arrive: '2 1 a r•m �_ Depart: Z- ' am nAC
742 Bay Road, Queensbury, NY 12804 Inspector's lnitia s: 4,1'
NAME: Q i P\--Q-V\ r\.-a% �t 1 \ PERMI > > ' 1
LOCATION:? 5S I�1V '� t cry, DATE: -)
COMMENTS:
Y N NA
Chimney I"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6" in 10'or Equivalent
Interior I Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in. /Step Risers 7"I Treads 11" \��
Vestibules For Exit doors > 3000 sq. ft.
All Doors 36 in. w!Lever Handles I Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44" (I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight I Other Floors Okay - -
Relief Valve, Heat Trap I Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System -TT-A \ ' , \\f\--z_AT)L]
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers ` .�� • � ��T`���
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 %doors
> 10% > 1000 sq. ft.
' Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire cc) \ "5-1j1._
Dam_pers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft.Wood FramehC-LVcAc.. ) ?VAN C �7
Attic Access 30" x 20"x 30" (h), Crawl Space Access 18"x 24" ;
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond'Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access All Sides by 20'1 Driveable Surface 20'wide
Okay To Issue Temp. or Permanent CIO
Okay To Issue ClC
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Repost.doc Revised January 7,2008
Framing 0 Firestopping Inspection Report 1 m
Office No. (518) 761-8256 Date In pection a•, - ed:
Queensbury Building & Code Enforcement Arrive: 1 )_a . `. I _part: '( ) I/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initia Igo
NAME: C, 4 ERfMIT It
LOCATION: (;g-,n, Mcq (I INSPECT ON: j -/
TYPE OF STRUCTURE: b _ sZ--
/'_) 2 1 13`X �‘o
L Y N N/ACOMMENTS:
Framing \--7‘Nv,--1---i4 _,
Attic Access 22" x 30" minimum
Jack Studs/ Headers
Bracing/ Bridging
Joist hangers (---(1=1 \ r`\�L \v 17E-U,VC
Jack Posts/Main Beams
Exterior sheeting nailed properlyn. W
12" O.C. j =xlh«�
Headroom 6 ft. 8 in. ` \ ___-
Stairwells 36 in. or more __-1----
Deck Bracing
Headroom 6 ft. 8 in. •
otches I Holes I Bearing Walls
,.,.;ii/
etal Strapping-for-Notches Top Plate
z,....1-1A-(w) 16 gauge (8) 16D nails each side
Draft stopping :jez . ].•. ► . f n
kC_ZA7°'' off• . • less on center L—
Ice and water shield 24 inches from wall 6 ,N� (Z.- __-- V�-o C tuKE
Fire separation 1, 2, 3 hour 1
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/ below grade
5.0 sf grade
L:\Building&Codes Fomes-OLD\Building&Codes\nspection Fomts\Framing Firestopping Inspection Report.doc Revised January 7,2008