2013-186 TOWN OF QUEENSBURY
• 4311
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20130186 Date Issued: Friday, December 20, 2013
This is to certify that work requested to be done as shown by Permit Number P20130186
has been completed.
Location: 543 AVIATION Rd
Tax Map Number: 523400-302-005-0001-051-000-0000
Owner: AFTAB BHATTI
Applicant: AFTAB BHATTI
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
R(r 11 TOWN OF QUEENSBURY
Issuance of this Certificate of OccupancyDOESNOT relieve the property aN
P /15(
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
1,40641 TOWN OF QUEENSBURY
r .
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20130186 Application Number: A20130186
Tax Map No: 523400-302-005-0001-051-000-0000
Permission is hereby granted to: AFTAB BHATTI
For property located at: 543 AVIATION Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: AFTAB BHATTI Commercial Alteration $5,000.00
547 AVIATION Rd Total Value
QUEENSBURY,NY 12804-0000 $5,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2013-186 ECONO LODGE Rm. 119
Comm. alteration of 715 sq ft
$143.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,May 13,2014
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbury; Monday,May 13, 2013
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
r
OFFICE USE ONLY
TAX MAP NO. ;
D I I PERMIT NO. I _pa ,
_. 1..
FEES: PERMIT-�— RECREATION ENGINEERING_ _ MAY ;1 '
- Jjij`,
(If applicable) ;
PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING
PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW
BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: CcOoO (7C OWNER: 7974---7-A6 ern-177-7 •
ADDRESS:•--5 // 167/.7 � / ADDRESS: ,I9,... v./q. i---to yJ <Ci
PHONE NOS. S/� 7e7c3 37cc PHONE NOS. 57 7e7-6" eF ? c�//
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: PHONE:
LOCATION OF PROPERTY: .5-" ,,S y /q--176/) ed
HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? E YES 'a NO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT pzAPPLY TO YOUR z o E-
p Cr w wPROJECT OOH 0 • cn � �w
D JIL � w W Q QO. 2U
I— u Z I--
0
— O
LI W O J z ('� I— I-- OI— LwZ
Z < \< .‘s—• (Y) Ncl) OW I— LI— QS °ZS
SINGLE FAMILY ,
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3) klyyt._
OTHER �G•/'1,�In C�tG ?C 71clr
.CRO a i>"1 l I
IF COMMERCIAL OR INDUSTRIAL- AME OF BUSINESS: EY' (D . O �C) 7 6Z
ESTIMATED CONSTRUCTION COST: Sj27aO __ FUEL TYPE:
HEAT TYPE: `HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION:
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? J \.
i o
ARE THERE EASEMENTS ON PROPERTY?
"Please complete a separate Applicaticn for`Fuel Burning Appliances&Chimneys' available in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, l or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed 4/6
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes
or septic systems)
•
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application:
BUILDIN & O1 7"PROVAL ZONING APPROVAL
DAT DATE
QUESTIONS? CALL 761-8256 OR EMAIL
codesqueensbury.net
Office Use Only �j VISIT OUR WEBSITE FOR MORE INFORMATION
Operating Permit Issued: Yes r No www.queensbury.net
Occupancy Type: -2' Construction Classification:
Assembly Occupancy Limit: Special Conditions:
Town of Queensbury * Community Development Office * 742 Bay Road, Queensbury NY 12804
Inspection Form
Town of Queensbury Fire Marshal C) Periodic Inspection Date: Time:
742 Bay Road,Queensbury NY 12804 __Re-Inspection 1 f 8
518 761 8206/518 761 8205 CO Inspection Permit#:
Fire Marshals Representative
MJ Palmer Business Name: G e.-br e- R
Location: _ E
GK Stillman Contact:
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 NOTES
Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2 �,) y- t7
Sign:Normal FC 1011 &FC1029 i` f
Sign:backup FC 1011.5.3&FC1029.7.5
AISLES: I' + /LAJ
Main Aisle Width FC 1024/1025&FC1029.11
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906
Inspection of extinguisher FC 906
EVAC Plan FC 404.2
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3
Clearance to Electrical FC 605.3 - 1 j\ --k1
- 1r'
Electric Wiring Enclosed/Labeled FC 605.3.1 V
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6(R1 &R2)
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage PC 315.3 REINSPECTION DUE APPROXIMATELY
Vacant Buildings FC 311 _
Emergency Disconnect FC 2203.2 21 DAYS
SYSTEMS: FC 901.6 lnsp OK NC DATE: OK NC
Dote
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown _
Sprinkler System Annual
Sprinkler FDC
Kitchen Suppression Semi Annual
_Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506
Operating Permit, if required will be issued after
Completion of Inspection
Multiple Dwelling, Hotel, Motel, Apartment
Final Inspection Report
Office No.: (518)761-8256 Date lns•ection -que -.:
Queensbury Building&Code Enforcement Arrive: • '•rW- Depart am/pm
742 Bay Road,Queensbury, NY 12804 Inspector's Initials:
NAME: gm 117 PERMIT#: / 3— / E6„
LOCATION: Y 7 3 ytf) (Q4-I0f} iced DATE:
Y N NA COMMENTS:
Chimney Height / "B" Vent / Direct Vent Location
Plumb Vent Thru Roof Minimum 6"
Roof Complete
Exterior Finish Complete / Finish Grade 6" In 10' Drop
Interior/Exterior Railings 34 Into 38 in. / 36" Landing,
Decks, Porches
Exterior Handrails, Balconies, Landing 30" Or More
Interior Handrails Balconies / Landing 30" Or More
Interior Handrails Stairs 1 or More Risers
Guardrails 42", Ballisters 4" Minimum Spacing
Vestibules For Exit Doors >3000 sq. ft.
Doors 36" / Lever Handles
Headroom 6' 8" on Stairs
Bathroom / Kitchen Watertight
Smoke Detectors: Every level, Every bedroom
Outside every bedroom, Interconnected Battery
Backup
Carbon Monoxide Alarm - lowest sleeping level
Bathroom Fans / Plumbing Fixtures Complete •
Foundation Insulation
Fire Separation, 3/4, 1, 2 hr.
Fire Walls 1, 2, 3 Hour / Fire Door 3/4, 1 1/2, 2 Hour
Handicapped Accessibility / Handicapped
Parking/Signage
Gas Log In Sealed or Glass Enclosure
Gas Valve Shut-Off Exposed / Regulator 18" Above
Grade
Gas Furnace Shut-Off Within 30 ft. or Within Line Site
Oil Furnace Shut-Off at Entrance to Furnace Area
Furnace / Hot Water Heater Operating / Fresh Air Intake
Low Water Shut-Off for Boiler
Relief Valve, Heat Trap / Water temp 110 Degrees Max.
Garage Fireproofing Complete, Penetration Sealed
Furnace In Separate Room / Protected (In Garage)
Light Ventilation per Room / Safety Glazing
Attic Access 30" x 20" x 30" (H) / Crawl Space 18" x 24"
Final Electrical
Site Plan/Variance Required
Final Survey Plot Plan / Flood Plain Certification, if Req.
As-built Septic System Layout Required
Building /Apartment Number on Building or Driveway
Build Access All Sides by 20', Driveable Surface 20" Wide
Okay To Issue Temp C/O or Permanent CO (circle one)
Okay To Issue C/C
L:',B&C APPLICATIONS-OFFICE USEIMULTIPLE DWELLING.doc
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date inspection request received:
Queensbury Building & Code Enforcement Arrive: j21/3 am/pn .i Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �
NAME: , � Le ccf IL PERMIT #: I 3-- AzcP INSPECT ON:
TYPE OF STRUCTURE: Prn,,r,r, ( ,
m c: /#10
_ Y N A
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet I change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation / Residential Check t Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/Hot Water Piping Insulation
If r uired unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape
COMMENTS: (\ /</Q)
(At. 3- /9
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008
q--/f
Rough Plumbing I Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: 1/6 am/prr3 Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME:� C Jcr(siC _ PERMIT : 1 3 )
LOCATION: S ° �� � j m 1 INSPECT ON: f 6t—r
TYPE OF STRUCTURE: 0..0 ,,\,N l=t
_ Y N N/A ;\
Rough Plumbing / Nail Plates�
Plumbin• Vent/Vents in Place ji
1 'A inch minimum Drain Size _
Ri-1
/>Washin• Machine Drain 2 inchminimumZ/1
Cleanout eve 100 feet/ change of direction
Pressure Test
Drain /Vent
Air/ Head i
5 P.S.I. or 10 ft. above hic lest connection for 15 minutes
Pressure Test /
Water Supply Piping ✓
Air/ Head
50 P.S.I for 15 minutes _
Insulation / Residential Check/ Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window SealedINo Insulation)
Duct/ Hot Water Piping Insulation
If r uired unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape _
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008
Framing I Firestopping Inspection Report ,� C=el c1-1/Il
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: --'7(6 am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: el__
3 -
NAME:_ Com, 7-- L,- c. PERMIT#: nr= •
LOCATION: v :, yr eggin INSPECT ON: L' -i 9-i 23)
TYPE OF STRUCTURE: CL.r\ Pi .i
Y N N/A COMMENTS:
Framing
Attic Access 22" x 30' minimum
Jack Studs/ Headers
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes / Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge (8) 18D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestoppin ✓
Penetration sealed i,
16 inch insulation in cavity min. ��'e �' ``'`"
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space I Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above / below grade
5.0 sf grade
L:1Building&Codes Fortis-OLD\Building&Codes\Inspection Famts\Framing Firestopping Inspection Report.doc Revised January 7,2008
utrS *1)1
Rough Plumbing I Insulation Inspection Report
Office No. (518) 761-8256 Date Ins ction request received:
Queensbury Building & Code Enforcement Arrive: J 1, a am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Li/
NAME: C� T PERMIT #: 3- / s t�
LOCATION: C ,D �,�� _ .aJNSPECT ON:
TYPE OF STRUCTURE: --
V
.V N
RoughPlumbing / Nail Plates /
Plumbing Vent I Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test ~�
Water Supply Piping 1/
Air/ Head
50 P.S.1 for 15 minutes
Insulation / Residential Check/ Commercial Check
Tyvek or Similar Exterior Sealant — -��
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation) _
Duct/ Hot Water Piping Insulation
If required unheated spaces _
Combustion Air Supply for Furnace _
Duct work sealed properly I No duct tape — 1
COMMENTS: C4 �� f.,, a -� E l��'�}fes 7 �
Rough Plumbing Insulation Repert.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008
Framing I Firestopping Inspection Report I Kwtz, A-re)
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: // s`2 am/pm ,,Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's initials: )%
NAME: PERMIT#: it 3' 1
LOCATION: 5 413 4birion _ rn INSPECT ON: 3
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing V
Attic Access 22" x 30" minimum
Jack Studs/ Headers
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches I Holes 1 Bearing Walls
Metal Strapping for Notches Top Plate
1 'A(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping N;f- l'°-6"
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side ' inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/ Bedrooms
24 in. (H)
20 in. (VV)
5.7 sf above/ below grade
5.0 sf grade
L:\Buiiding&Codes Fom1s-OLD\3uilding&Codes\Inspection Forrns\Framing Firestopping Inspection Report.doc Revised January 7,2008