2013-303 e TOWN OF QUEENSBURY
742 Bay Road,Qucensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20130303 Date Issued: Thursday, September 18, 2014
This is to certify that work requested to be done as shown by Permit Number P20130303
has been completed.
Location: 31 BIRCH Rd
Tax Map Number: 523400-289-013-0001-020-000-0000
Owner: PAUL & MARGARET SHEEHAN
Applicant: MICHAEL PHINNEY
This structure may be occupied as a:
Fireplace By Order of Town Board
Garage Attached TOWN OF QUEENSBURY
Single Family Dwelling
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan, Variance, or ca ,f
other issues and conditions as a result of approvals by the Planning Board Director of Building& Code Enf come
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
w 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
f
Community Development- Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20130303 Application Number: A20130303
Tax Map No: 523400-289-013-0001-020-000-0000
Permission is hereby granted to: MICHAEL PHINNEY
For property located at: 31 BIRCH Rd
in the Town of Queensbury, to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: PAUL& MARGARET SHEEHAN
23 SYLVAN Ave Giarplace
Garage Attached
QUEENSBURY,NY 12804 Single Family Dwelling $475,000.00
Total Value $475,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
BRIAN ZDGIEBLOSKI
469-2824
1941 BAY Rd
LAKE GEORGE NY 12845-0000
Plans&Specifications
2013--303
SFD 1st Flr 1,664 sf; lower level 1,149 sf
Attached Garage 568 sf/ 1 fireplace (gas)
$647.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,August 05,2014
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of ens '`�' f;l i •, , ugust 05,2013
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
Town of Queensbury Building & Codes Received: ZOi
PRINCIPAL STRUCTURE APPLICATION Tax Map ID: P 1 3 - 1
Permit No.: / -
A permit must be obtained before beginning construction Permit Fee: $ '`1 .S, 5 1-50 F
Please read: *TB resolution 86-2013(1-28-2013): $850 recreation fee for new dwelling *Rec Fee: $ SS
units, including single-family dwellings, duplexes or two-family dwellings, multiple family Site Plan No.:
dwellings, apartments, condominiums, townhouses, and/or manufactured and modular Subdivision No.:
homes,but not including mobile homes. This is in addition to the permit fee.
Date July 8,2013 Applicant M1C.A. A (. �4{-i',% Ly
Tax Map ID 28q. 134-20 Address 142 &RAW> /601S.
Zoning \1 R -- SARATo6A PR t'.1& ,N`/ (2.866
Phone/E-mail (SIR) 567-7120
Property Owner 17kUU . -5-REEN-ANi Contractor/Agent tNRspI Z126-16$1t.sk.t
Address .2 6YLVAI,1 AVE,. Address I941 Bay 'RccD
6tuE.,Et`1Sg(JRY rJY 12`6O4 (m-z Cs R68 1l`t 12-MS
Phone/E-mail 051.8) 743-(oS aC0 Phone/E-mail C5(g) 464-2B2�I
Contact Person for Building&Code Compliance: DAitJpk TEM t.1 -i �1�t ,`( t6rJ(Da Day Phone: (.518581-1 12D X•15
Building Street Address: 3 t iPtc tk p12.
Subdivision Name: Lot#: Historic Site: Yes y No
Estimated cost of construction: $ 475,oto
Type of Construction:
Check all that apply Please indicate measurements as required below:
o c
1st Floor 2nd Floor Other Total Height
F a a �LoIti1F.R} Vu)
Single Family Wolf 5.G 1114q 5•F 9-1813 S.P. 211-91/2"
Two-Family
•
Multi-Family(#of
units_)
Townhouse
•
Business Office
•
Retail-Mercantile
Factory-Industrial
Attached Garages(# ) X g 5•F. ICar-10"
Other
Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256
If commercial or industrial indicate name of business
Proposed use of building or addition 5 .0(011 (y S ID�,>f1(x
•
Source of heat(circle one) Gas Oil Propane l Solar Other
Fireplace-complete a separate application for"Fuel Burning Appliances&Chimneys" ✓Yes _No
Are there structures not shown on plot plan? 1.10
Are their easements on the property? f.10
Site Information
a. Dimensions or acreage of lot 0,�q.
b. Is this a corner lot? t40
c. Will the grade be changed as a result of construction: ✓Yes _No
d. Public water APriyate well l
e. Sewer oPrivate Septic System 1
it
Value of all work to be performed(labor and materials) $ 47557
Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval. I certify that the application, plans,and supporting materials are a true and complete statement/description of the
work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances,and
in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a
certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Print Name:
Signature: ' (l —� tiall Date: 7. g
FOR OFFICE USE ONLY:
Operating Permit Issued: Yes No
Occupancy Type:
Construction Classification:
Assembly Occupancy Limit:
Special Conditions:
Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256
Office Use Only
Town of Queensbury Building & Codes Received:
Tax Map ID:
FUEL BURNING APPLIANCE & CHIMNEY APPLICATION Permit No.: /3 -30.3
30.3
Permit Fee: $
Application is hereby made to the Building &Codes Office for the issuance of a Building & Use Permit pursuant to the NYS Fire Prevention&
Building Code, The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of
these requirements and also will allow all inspectors to enter premises to perform required inspections.
Important Note To Applicant: Rough-In and Final Inspections Are Required:
Date 301y 81 2013
Owner "PALL, -Z. stle.stkAtA Installer/Builder ?7V-1.At.1 Z ri eP,,to5k.i
Address 23 5'ital4f.1 .fit Address t?4( 199 "RDOG
62U--ei.15Px5R%+ uY 12845 ,(AkICC bee ,,,Yt 12645
Phone 516- -lqb . Cp5610 Phone (5(8) 461- 2-82-4
Location of proposed construction and/or installation: -51- 13i kC 4*`RV/ &ut ENSt3OZ1, tiY 12-545
Contact Person for Building & Codes Compliance: JDA-1 att- TERPt -TR-C t't IEES(kS 0200P- 587-7(20 t(S
Subdivision Name:
Fuel Burning Appliance Information Wood Coal Pellet Gas Oil
Stove
Fireplace Insert
Fireplace,factory built*
Fireplace, Masonry _
Furnace, (Garage Only)
* If Factory Built, Please Provide: Manufacturer Name: Model No.
Listed By: Number:
Chimney Information
Masonry** ✓check one —Block —Brick —Stone
Flue check one Tile ✓Steel Size in Inches
672
Material "check one Double Wall _Triple Wall —Insulated Direct Vent —Chimney Liner
** If Non-Masonry, please provide: Manufacturer Name: t4t.i-Crb Model No. 6c00 GL—X
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION & BUILDING CODE AND/OR
MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE Town of Queensbury HANDOUTS REGARDING REQUIRED INSPECTIONS.
Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256
Office Use Only
Received:
Tax Map ID:
Town of Queensbury Building & Codes Permit No.:
SEPTIC DISPOSAL PERMIT Permit Fee: $ 1 3 —_303
A permit must be obtained before beginning construction Approvals:
Applicant: K Iuk nt4X Installer/Builder 13tLLik.1 21,)b-it✓ 1o54Ct
Address: 142 GPM t' AVE.) Address I 4141 3 t,{ -RCM)
To&A 5B2.046st iW 121366 lA(Lt✓ itri2b )1/43 Y 12fs5
Phone: (I;NS) Phone L3($) 46c1- $324
Owner: II L ? • 5.14E•54+,401.1 Location of Installation I,UEd - 51 OE tPT20PE:gti
Address: 23 &ICNht4 AVE-t4UE - 7E=,G ?(CT RAO
CBW 3ORy ,MY 1 i '?-
Phone ;,) 7673- 69q0
Contact Person for Building&Code Compliance: 17:311/44t'-A 175177114 -1214411/410.1 VF.6t6#J Day Phone: 567"7120 X 15
CSP
Residence Information:
Year Built #of Bedrooms x Gallons per bedroom =Total Daily Flow
1980 or older x 150 = Garbage Grinder installed? t'l()
1981-1991 x 130 = Spa or Hot Tub Installed? N30
1992-Present 3 x 110 = 350
Parcel Information:
Topography 2( Flat Rolling _Steep Slope %Slope
Soil Nature % Sand _Loam Clay _Other
Groundwater At what depth? 7
Bedrockllmpervious Material At what depth? 7 Gorr
Domestic Water Supply Municipal X Well(if well,water supply from any septic system absorption is la) ft.)
Percolation Test Rate- 6:60 per minute per inch(Test to be completed by a licensed professional engineer or
architect)
Proposed System for New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or
architect(unless installed in a Planning Board approved subdivision).
Tank size 1,000 gallon (minimum size 1,000 gallons),add 250 gallons to size of septic tank for each garbage grinder,spa or
whirlpool tub
X 26t-t NGl- W tDG Lt4AM P" ?2 )
System Type: Absorption Field(with#2 stone) Total length 144 ft. Each trench 3 X 481
Seepage Pit(S)(with#3 stone) How many? Size?
Alternative System Bed or other type?
Holding Tank System Total required capacity? Tank size? #of tanks?
NOTE: 1)Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency-see Certified
Electrical form on Town website;2)Effective as of March 23,2006 Septic System-As Built Plot Plan: The Building Department will no longer
allow systems to be covered until such time as an As-Built Plot Plan is received and approved by the Building Inspector. The installed
system must match the septic system layout on file. There will be no exceptions.
For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted
which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known
by or on behalf of an applicant,shall be void.
✓I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury
Sanitary Sewage Disposal Ordinance.
Print Name: !111 ,dG L Nt/A1Al _r Date: ?• eip `f f7
Signature: - • _.�., ALA.A..4 Date: 2' O /b
Town of Queensbury Building : Codes Principal .tructu e Packet 518-761-8256
Town of Queensbury Building &Code Enforcement
Office No. (518) 761-8256
Septic Inspection Report
Inspection request received: f
Name: c)� l Inspected on: /(ii ' Vt
n
Location: ' q:;� Arrive: t l a.m./
Permit No.: ( — 3C57) Inspector's Initials:
Comments and/or diagram
Soil Type: Sand/Loam/Clay
Type of Water: Municipal/We ater
Waterline separation distanc• ft.
Well separation distance ft
Other wells:
Well Casing Length :0'+/- Y N N/A
[150'to well required NO]
Absorption Field: 'otal length ft. lc c f
Length of each tr: ch ft. \�t/
Depth of trenche. ft.
Size of StoneEprj.
Seepage Pits: ! umber
Size:
Stone Size:
v
Piping Size Type
Building to tan
Tank to Distri.ution Box
Distribution Be x to Field/Pit
Opening Seal-d: Y_N
End Cap Y_N
Inlet/Outlet Pies&B." es Y N
Manholes 12' or les•below grade Y N
[provide exte sion ollar if Yes] Y_N
Location/Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits f
Conforms as per Plot an _Y N
Engineer Report an s-Built N
ETU Maintenance Contract provided Y N
Location of System on Property:
Front Rear Le ide Right Side Middle Front Middle Rear
S stem Use Status'
Approved
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved
Septic Inspection Report
169 Haviland Road
Queensbury, NY 12804
Hutchins Engineering Phone: (518) 745-0307
Fax: (518)745-0308
September 15, 2013 3, 305
Town of Queensbury Buildings Department S7 15 2014
742 Bay Road
Queensbury, NY 12804
Re: SP 76-2012
Paul & Margaret Sheehan
31 Birch Road, Queensbury, NY 12804
Tax Map # 289.13-1-20
This office prepared the site and wastewater design plans for the referenced residence.
We conducted periodic inspections of sitework throughout the construction process.
It is my opinion that the septic system is installed in general conformance with the
attached record drawings.
Please contact me if you have any questions or if you require additional information.
Best Regards,
\=7‘kk-
G. Thomas Hutchins, P.E.
Cc: Paul & Margaret Sheehan
Phinney Design Group
G.Thomas Hutchins,P.E.
440
I
Ilk
LANDS OF
WILLIAM CHASE
.t�
... :. .. .., -: t;•I r �- Y :i. 3 a r � � � si"<w� r .�^ rs` • .:: <. .. ,.r:_ �.. ., e, r , -r .i a ': t -s
... �� ... - , �y 7• L.',: y... �*x r T� „r -.'- i 't,}'....*x` ✓r.:`"';:'... -c �t ,l r'-'_`.=,F=.`.,.� ,. . Pm`. `�^�' _L frT` �.� r.ttp . , �. r' ,-��-1;:-; r �f Y'"=`=
• Y. { .. .. 4 t :':m'.`t . a. .,:::.: .:, .. ,.,f `v -..r' �, r..:."- rv, r3' s^t., ;i .r :rr'.:� ,x� .. rJ' ._ .v ,.r,.,�r :;c-.
S . SITE- SOILS DATA
ZONING REGULATION
f.,,r.,+,�,- ;
�1�`
UEENSBURY TEST PITS
TOWN OF Q
v.r vr: s Lt x r
LEGEND. _ ' TP T. HUTCHINS P.E.
,.,10/4/2012 BY ,y�. :d I € r:.•:,.r � �{.a�.. -: te�.:._.r�,,j __ -1 -<:: i ",�: .i� ..'�,'�.~Y.
s
WR WATERFRONT RESIDENTIAL
_ $':,x -;1�� }� , .-Y. � ;.flit +'u, '`+V•,d .• :_`"x.:� of .d, _ , t fr Se v.- '? ' .n:`:. � f: i.F
f L ...:i....l,. - .': m: , ...;.r � • i'i. Le"'_-`, _'.:.: s + ., y .I .. .ry ..� -.'^+. c ':':{ .. ..i .. �.,.. i -x - �':� attc.
IPF IRON PIPE FOUND DIMENSIONAL REQUIREMENTS. WITNESSED B YCHAZEN COMPANIES
FRONT SETBACK - 30 0-10,
*=a€
TOPSOIL
s cn
- . . r. F
GRAVELLY SAND, SETBACK 30 10 ® IRF IRON ROD FOUND SHORELINE SETBACK 50'
RS IRON ROD SET 40% COBBLES &BOULDERS
SIDE SETBACK - 20 'r ,t _,.,, .,. n-.[.' •:7&,
..
MINIMUM PERCENT PERVIOUS 757
UTILITY POLE ROOTS ENTIRE DEPTH
,. T '-tea• a�:..} '^^ .r s.'.,, .�' �.;::,..:'>_r�(pj ,.. .. ,�..,. x r. •..: f _ J::= .- :,l_r �..
APPROXIMATE MAXIMUM BUILDING HEIGHT 28 , NO SEASONAL HIGH GROUNDWATER EVENCE,.
_ � , t..._ r ..-... ____ __..��-� . ,_ ._ ., u- f• , , ;,-,✓ ,.,.. , .. ,x , Y::. ., - � -_. , r_:n.
EXIST.:.MAXIMUM FLOOR AREA , .227 ... x ..
WASTEWATER ,, E. %,�.
R
PROP
F4L„ PROPHERBACEOU_S BUILDING HEIG.H,T, CALCULATION
ALCULATION f--
HOHOUSE PLANTINGS TYR) UH SIDE) €
4E EXISTING GRADE AT RIDGE .
PROPHDPE GRINDER"k,
, MINSLOPE 98 MAXIMUM BUILDING HEIGHT '408.9 + 28 4369PUMPSTATION
.
4 QOTINGDRA36.9 �:MAXIMUM ALLOWABLE RIDGEELEVATION Zf� '-X-1
fi
'ON.-NErC5 BASE FLOOR TO RIDGE MEASUREMENT
. <E ' 2..7. . .....11:`. 5 8 (FROM ARCH
PLANS)
LANS
Y.<OTHER.0
45.
sraRsIR_.: f ,PROPOSED BASEMENT FLOOR ELEVATION 4088S
-- I '- i1"=..•t,,=.ti:="<".
_ '..., :, ."t . .. ,-,;,•.,., .. ,_.._t .: y.a. .T. _ - =.i-..,. .g._. . . _ 1 >rx...:.,":..,�:.c�:+....:r ,,.3 s.:...s . E,
. •, _+.Errr.,-,,-,�I,: u . . 4-,<x. ':w,::ir�_r.,.- . .., ,-_•3 _t_. ,,ra. rv.. ::.S.v..:�.. �-:.,._.;u'�'_..„.. y .._..v,�. ff x.:.__?._+.�_.,.. > .r >_..-_,<.e^,:•-i.., - . /,..:r.-...a:�=' .. z K -' h ,. n* .d __ .:r. }S:rt.-,�., �: x a -.;::,jv."<Y::,s-:� .. _ . "� f�f..r,.:.�_,�.nxr.:�-.�.'.uG-..,.-;:... ,r'r 1 a,�„,,L '�...-�..__,r. r . :..:_ ..x t,,.,->,-,S^_'.,I'!'r'..s,., t....-:,�.,.� .�.; Y: - k,'.
LyROAD 797-436.77
1f{-^sTEPPiNGsroNE PROPOSED RIDGE ELEVA138
PATHWAY EIGHT 2787. .. PROPOSED BUILDING H
t/>
'
, ".;, - � � ,- �_ �'` �, .: a,,s ;{,: �, �,. .. d� .,-:�;o .<. =- F >£r .:lit -rx,- {1�,?`•' r t,
l
/: s m. /=J="` f ...-" >E'i" .. < e ._.. i .. 3..,• -tom+-. .,-{,. '! rt.'-,..
ACCEPTABLE PLANT
SPECIES
DOCK BOTANICAL NAME7COMMON NA;'� :., -,- ,.„::,..a�`�.F ,,,;.�.n.'+, ♦ +.� . ,",. r_ . $?". ,- ti".�..t.r. ? + N:F'+ %f ,.e.r. - �5's`3kx, r: n�sna+_;,!#§N:?,.�ry�k , ... ,.. .u.t.ti✓x_. -_. ...,,c-, ^ �aT�x„,,.l,_'x� .".x,a..._.v.......�x. --•._x,,/f ,.4�"x:x=�%..,:�... ��,:`...:�_... r � ..�r_',...�§,� m:.'rs._,_�-,. x.vc~.-,,,,...,e;s.",t.`J:+...'.x-,.. �hS,.�:f:.-'. ,=�"3.'a ��, �m. .F%- \"� «d,-_fi1?.ia, �; �_- .::.�:: r_.� �.�e.,,c3.. .�.t._�n.fY -r -;,-:-..
:.
LARGER TREES (CANOPY)
��s x ,,:nr, „r � , +:. rr s ,:.�- _ r.kir t;:�s.rs , �,� 'v, r, �t .::x:, � � ¢:.� S=.•, .47 + : k �.�, � . � x;. -`7
oI W I® LL4 ; i ..... PICEA MARIANA BLACK SPRUCE
W -� SITE LOCATION LOCATION MAP
U, Pu P PROP. SRUB THUJA OCCIDENTALIS EASTERN ARBORVITAE'
t MIC u
Ij ® ,l .y. o w (15T'YP.) ACER RUBRUM RED MAPLE
PROP SEDIMENT PICEA GLAUCA WHITE SPRUCE PLANTING NOTES
6 O
O ZONING' BOARD OF APPEALS APPROVAL
Lv CONTROL FENCE Zoning Board of Appeals - Record of Resolution
LARIX LARICINA - AMERICAN LARCH g
W Town of G ueensbury 742 Bay Road Queensbury, NY 12804 (5181761 8238 1. PROTECT EXIST NG TREES INDICATED TO REMAIN FROM SKINNING AND
} DRAIN } --1 FRAXINUS NIGRA BLACKASH ": ,' - FILLING AROUND BASE.
- . -Roy Urrico Secretary ..{
) -5tevenJackoskr Chairman 2. THE CONTRACTOR SHALL INSTALL 4" TOPSOIL IN LAWN AREAS AND 9"
(
gF '408. n SMALLER TREES & LARGE SHRUBS UNDERSTORY
PROPOSED WELL
: � r
�� � s .. h MAINTAIN 100 SETBACK
TO ABSORPTION FIELD
/
ern .F en PROP. HERBACEOUS
j
. } 'l -0LANTINGS(TYP.)
u r' REMOVE EXISTING BUSHY
�- VEGETATION, STABILIZE WITH
®• _._ '�,T `, p� BOULDERS AND REPLACE WITH
• POINT TJ 15-20 PLANTINGS FROM
`, �. •., \BUILDIhjG HEIGHT
RECOMMENDED LIST
NATIVE GRADE 408.9
6:9 PROP. WHITE_ 1
�(3 SPRUCE (4 TYP.)
HOUSE
)XIMATE
ro3
u
. SEPTIC TANK
SEPTIC TANK OUTLE II LANDS OF r
VIBURNUM TRILOBUM
AMERICAN CRANBERRY
ARONIA MELANOCARPA
BLACK CHOKECHERRY
CEPHALANTHUS OCCIDENTALIS
BUTTONBUSH' ,.
SALIX BEBBIANA
BEBB'S WILLOW
SPIRAEA ALBA
MEADOWSWEET
NEMOPANTHUS MUCRONATUS
MOUNTAIN HOLLY
LINDERA BENZOIN
NORTHERN SPICEBUSH
ARONIA ARBUTIFOLIA
RED CHOKECHERRY
CORNUS SERICEA
RED TWIG DOGWOOD
SALIX LUCIDA
SHINING WILLOW
ALNUS INCANA
SPECKLED ALDER
SPIREA TOMENTOSA
STEEPLEBUSH
MYRICA GALE
SWEET GALE
LLEX VERTICILLATA
WINTERBERRY HOLLY
HAMAMELIS VIRGINIANA
WITCH HAZEL'
ih' 1 d f b
1
=
TOPSOIL IN PLANT BEDS AND ROUGH GRADE. THE CONTRACTOR WILL
PROPOSED
WR ZONE
To: Paul & Margaret Sheehan .. PROJECT
FOR: Paul & Margaret Sheehan
PROVIDE FINE GRADING SOIL AMENDMENTS.
44.8'
52.4'
23 Sylvan Avenue
, :' 31 Birch Road, Glen Lake
.AND
31.1'
[EIDECNORTH)
Queensbury, NY 12804 `
10.6'
3. AREAS INDICATED AS LAWN SHALL BE SEEDED WITH LOFT'S TRIPLEX
1715 SF
20'
57,8'
22.4'
GENERAL MIX, OR APPROVED MIX; AT A RATE OF 5 LBS PER 1000 SF AND
DECK @ LAKE
195 SF
The Queensbury Zoning Board of Appeals has
reviewed the following request of the
MULCHED WITH STRAW OR HYDROSEEDED. -
1510 SF
2280 SF
below stated meeting and has resolved the
following:
4. PLANTING SOIL FOR BACKFILL OF NEW PLANTS AND PREPARATION OF
1460 SF
;
PLANT BEDS SHALL BE A MIXTURE OF 1 PART TOPSOIL, 1 PART
TOTAL IMPERVIOUS
Area Variance No. 62-2012 Paul and Margaret
Sheehan
COMPOSTED MANURE, 1 PART PEAT MOSS AND PHOSPHOROUS FREE
PERCENT IMPERVIOUS
14.4%
eehng Date; December 5, 2012
8.7%-
STARTER FERTILIZER AT 1 LB PER 20 SF.
Approved x �'
- 5. MULCH FOR TREES AND SHRUBS SHALL BE COARSE SHREDDED BARK,
"
FREE OF WOOD CHIPS, LEAVES OR OTHER UNACCEPTABLE MATERIAL.
6. MULCH FOR PERENNIALS SHALL BE FINE SHREDDED BARK, FREE OF WOOD'
MOTION TO APPROVE AREA VARIANCE NO.
62-2012 'PAUL AND MARGARET SHEEHAN
CHIPS, LEAVES -0R OTHER UNACCEPTABLE MATERIAL
Introduced by James Underwood who moved for adoption, seconded by Richard
Garand:
STABILIZATION
31 Birch Road. The applicant proposes to demolish an existing 1,352. square foot
residence with accessory structures and construct new, 2,597 square toot, three
1. THE CONTRACTOR SHALL INITIATE STABILIZATION MEASURES AS
bedroom residence. Parcel will require a variance for, road access because they share
p
SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE
a drivewaywith their next door neighbor, the Chases. The request for actual
physical 9
9 P Y
�
access from road frontage requirements is a requirement by the Town Code, but due to
ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN
the fact that the lots are 100 feet or less and in this instance I think it's 100 feet plus
along the shoreline, to. require them to put in their awn driveway would be redundant,
NO CASE MORE THAN 7 DAYS.
" 't ih
J, ! ,,:TOPSOIL, SEED & INSTALL \ y and so, in ,s request, we, on eel ere II a any impacts because the driveway Is
LAN EROSION CONTROL BLANKETS ALICE GENTHNER \ HERBACEOUS PLANTS (PERENNIALS, GROUND COVER) already existing. There is a new arrangement being brought together the two 2. STABILIZATION OF GRASS AREAS INCLUDES HYROSEEDING USING
HERBERT LEVIN ON CUT-SLOPE/NORTH AMERICAN
GREEN S
GR C R EQUAL
1500
. .. PLANSETBACK
SITE S
. . ,. _.,DUCE .�
WA WASTEWATER ' CHE
S S 5. .
_ r
a
SCALE: 1 "=20' ,
e
SITE SETBACKS
TOTAL LOT AREA
REQUIRED FOR
EXISTING
PROPOSED
WR ZONE
15,500± SF
SHORELINE
50'
44.8'
52.4'
FRONT
30'
65.8'
31.1'
[EIDECNORTH)
20'
10.6'
22'
1715 SF
20'
57,8'
22.4'
SITE DEVELOPMENT DATA
TOTAL LOT AREA
0.64± ACRES
28,021± SF
BLUE FLAG IRIS ".
.VERBENA HASTATA
TOTAL DISTURBANCE
15,500± SF
BROAD'LEA VED CATTAIL
LOBELIA SIPHILITICA
GREAT BLUE LOBELIA
EXISTING
IMPERVIOUS AREAS
PROPOSED
IMPERVIOUS AREAS
CHANGEIN
IMPERVIOUS AREAS.
MEADOW RUE
VERNONIA NOVABORICENSIS
NEW YORK IRONWEED
HOUSE/PORCH/GARAGE
820 SF
2535 SF
1715 SF
ACCESSORY STRUCTURES
50 SF
(50 SF)
DECK @ LAKE
195 SF
195 SF
DRIVES/WALKWAYS _
1510 SF
2280 SF
770 SF
BIRCH RD, NEIGHBORING DRIVE
1460 SF
1460 SF
;
TOTAL IMPERVIOUS
4035 SF
6470 SF
2435 SF
PERCENT IMPERVIOUS
14.4%
23.1%
8.7%-
M ONDARDA DIDYMA
BEEBALM
IRIS .VEfJSICOLOIFW �; ; ,
BLUE FLAG IRIS ".
.VERBENA HASTATA
`BLUE VERVAIN
TYPHA LATIFOLIA
BROAD'LEA VED CATTAIL
LOBELIA SIPHILITICA
GREAT BLUE LOBELIA
EUPATORIUM
JOE PYE WEED
THALICTRUM DIOIOUM
MEADOW RUE
VERNONIA NOVABORICENSIS
NEW YORK IRONWEED
SENNA HEBECARPA
WILD SENNA
neighbors and the two parties involved, d so even though its a self-created, I do
n t
really feel it's self created. I feel it's ust co dttions ast e are and they're just trying io
TACKIFIER ON SLOPES OVER OR SEEDING AND INSTALLING A
maintain chose conditions. So I would move for,is a vprool s
=• ,
,
k -_CONTINUOUS COVER OF STRAW MULCH WATERED INTO PLACE. ON
Du IY. ado Pfe.-mde.nthsa, 5.m .
aY of e 2012 by the following vole.
SLOPES
OVER 1:3 INSTALL EROSION CONTROL BLANKETS
OR WOOD
A
Mrs: Hurif, Mr. Umcb; Mr.Garrand, Mr. Underwdod, Mr. Jackosb
. ••„ '' 'CHIPS `IN ACCO" D
-- ._; NoBs NONE' I'. R ANCE 'WITH THE DETAILED EROSION CONTROL
ABSENT: Mr: Kuhl,��g' PLANS AND IN ACCORDANCE WITH :MANUFACTURERS INSTRUCTIONS.
STANDARD SPECIFICATIONS.FOR MULCHING
RUBBER HOSE J:
FRICnON GUARD DEFINITION -
GUY WIRE APPLYING COARSE PLANT "RESIDUE, , OR CHIPS,= OR I OTHER SUITABLE
- MATERIALS, TO COVER THE SOIL SURFACE
,
< 3
PURPOSE, ,
3.sPLANTINGS NOTE.
z✓// , ° i THE 'PRIMARY:: PURPOSE
o PLANTS SHOWN ARE MINIMUM SUGGESTIONS,
PRP SE IS TO `PROVIDE INITIAL EROSION CONTROL' WHILE
O o 00 0
0 1 -1 2 TOP COURSE ASPHALT
a o, / - - ,' r� { A 'SEEDING -0R ':SHRUB .'•PLANTING IS' ESTABLISHING. MULCH;: WILL
o: O o CISH LOT_SPECIFIC :PLANTING$
o LOT OWNER MAY ESTAEi
MIN ,. 00,09.00 o;.o _ ,i ,: ,_,. I '
12.... t\ .._ � _ � ... � � _.....__.._._.-..:_ __ ..._:_., ..,.,..,..,..-:,.,. ..:.`�..-,. ..,,'r; t.. /A1P �' .- ;, (.CONSFRVF:MOISTfIRF AND MODIFY THF .SIIRFACF:S011 TEMPERATURE ANI]
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received:
NAME: -' 4
LOCATION:
PERMIT#: 20 esS —36
Final Survey Plot Plan
Approved Denied
The attached final
survey has been
received by the
Dept. of
Community
Development.
Upon review the
survey has been:
Craig Brown, Zoning Administrator
Notes:
L:\SueHemingway\Building.Codes.Inspcction.FORMS\Final Survey
Zoning Administrator.doc
n t Mrt i, MAP REFERENCE:
\ MAP OF LANDS OF
ZO14 JOHN E. SHEEHAN, MICHAEL F. SHEEHAN
AUG 0
c, \ AND PAUL R. SHEEHAN
DATED DECEMBER 16, 1989
TOK%j-1 OF QUEEN SIBURY BY COULTER & McCORMACK
PF \\
BU LD CODES
W \ \
o \ \ I
\ \ LEGEND:
-�� (0 0IPR=IRON PIPE FOUND
0IRE = IRON. ROD FOUND
\ c \\ LANDS OF O IRS =IRON ROD SEf
\ KGs \ WILLIAM CHASE Fn>= UTILITY POLE
Id
I � w
\ \. HOUSE
°
S82
_ 021-10"E
nE
-
STAIp5
I \ I N 145.00 IPF
O o
O N CRUSHED I IRF 8 ± r,• ��-
ST N
O q SURFACEW
N
Lu
o,yam I j \ i DOCK
PF f
I EEC.ME
- PROpAN I T F+
PANEL I n I
P I O PIT
WOOD FORS". I / �-cI wMTEe r
RA
ME
I i Q W r
AREA
r
28,020.71 sq. ft. I j IZ
O (C5
0.64 acres
r o . GLEN
X89
IPF _ _ _ — F�
CRUS - _ __ _ L,AKK
\ hED5T \. IPF N _ _� a2,o
ONF \ 274.61
\ N82°21,10"w ® N
� 3
LANDS OF
HERBERT LEVIN I Ar O
LANDS OF % tL
ALICE GENTHNERFc` "
HOUSE I
4q T IT
s IT
�o O any)iV
Date: August 27, 2012
�[�y Scale 1' 20'
�.'W.' vNAur IOGA°IIN510IVN05P OTOR 5AsvRvfY
/M1M11�.. J/`Jf!! Ml,�BCAPJNGAUGfNsfD IµDULOIVI 015 ,O15A
�. TV � �.SU�°Iv15Drvz.°ernf Map of I a Survey .made for
xcw roRRsrnre LDuuuoN
'ONLYCOPIfS PROM IIIc OWG WLLO-i1 R,`MRY ® "'
S t e -v e s MNTY1 µDWG lI'I,, nE VND SURVf40R5
®/ SPi1L5nNl GOnU14, IN1 °lW1PNPC9i Paul R. Sheehan
YLRS OCA11ON51NOTPRDIf NSIGNPTNIAr 1,}.Jj
R1155DRV O` I ijO. "ACCO ,NCIH 1xe
Y 1TNIGCO Uf Of PRA )Il£fORLWD SURmm PDOPffD
Lar^, C 7 'p r -v e qT o r C a orrnery xro srAr€ s rlorvoPPwfesslc /�
11 1`J 1.A 1 4� J 1 til "T'111V .V f 5Ng[Lµr1 Gf...... RUN DNIY SHLEr1 V1. 1
rO me r won rOI NO11C f mf suRvn s PRE✓ABED, N,D -
ory nlsaz�wls of eli¢coM nm cwexwecNUL
169 Haviland Road Queensbury, New York 12804 OT u5°N«NOF;;LUNo1NGNs M` °" Town of Queensbu y, Warren County, New York 1 7/25/14 ASBUILT CONDITIONS sNEE nN
I , C-2626
(518) 792-8474 New York Lie. No. 50135 N0. DATE DESCRIPTION Dw6. No. 12065
TAX PARCEL: 289.13-1-20
Queensbury Building & Code Enforcement - Residential Final Inspection —
�
Office No. (518) 761-8256 Arrive: am/pm De a • t am/pm
Date Inspection request`received: Inspector's Initials: llf p L
NAME: J"1 Q e* QV\ PERMIT#: / 3-30 3
LOCATION: -4 / Q a f DATE: LO—1 }7‘--!"il
TYPE OF STRUCTURE: ,5 i'
Comments:
lig,No NIA
4" Building Number Address visible from road
Chimney Height/°B"Vent/Direct Vent Location ."
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches i^
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs, decks,patios more than 30 inches above grade
:2/
Guard at stairwell at 34 inches or more
Guard at deck, porches 36 inches or more ✓``
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches ✓
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet tj
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grader ------- -`
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Win•ow in stairwells safety gI. ing
Interior Smoke De - ors/Carbon M oxid: Detectors
Every level: Eves+Bedro :
/
Outside every bedroomEve
Inter Connected: -/ Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents 1
Bathroom Fans,if no window
Plumbing fixtures .
Foundation insulation to floor/Sticker on Panel i/
Duct work sealed properly/Blower Door Test Certification — — 14-4R.-5-1214:,/ A h
Floor truss,draft stopping finished basement 1,000 sq.ft. / ___.--____________z
Emergency egress below grade
GasilFurnace hu-offshut-offwithin 30c feet or aceialine of site / f L_ , „ Q
Oil Furnace shut-off at entrance to furnace area / "W i- ��,r., f- �-L--
Furnace/Hot Water Heater operating ti/ `} ( �
Low water shut-off boiler S/ `
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum , / � �•�� � t _ � � (�'
Basement stairs closed rise>4 inches V/ r
Garage Floor Pitched t f" t (t`x1Z i
Garage fireproofing 1%hour fire door/door closer �/t://,<-Gas Logs in Sealed or Glass Enclosure /
Final Electrical; Energy Saving Light Bulbs 50% r/
Final Survey Plot Plan11
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles / `—r<��cl. ,0 " 3
Flex Gas Pipe Bonding y
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification, i 1/
Okay to issue C/C or C • [Tempora /Permanent I �J
---------7/6 "
L:1Building&Codes Forms\Building&Codesllnsppe ionctionct Forms1Residential Final Inspection Form revised_100405.doc;Revised
January 7,2008; Revised 6/26/08;Revised 12/22/10,Revised 04/13/11
! Lc 6y:
. Queensbury Building & Code Enforcement - Residential Final Inspection
- ;
Office No. (518) 761-8256 Arrive: am/pm Depart:"\. `'am/pm
Date Inspection request received: Inspectors Initials: /"t��,t •,�
� -�—
NAME: —=-N - P_. i\ Q v- PERMIT#: / 3-30 3
LOCATION: " : (', is. f' (+.fir\ DATE: I. — / )>-4-//
TYPE OF STRUCTURE: ¢:•(N:,
Comments:
Yes-'•-No N/A _
4" Building Number Address visible from road v--_,,
Chimney Height I"B"Vent/Direct Vent Location
Fresh Air Intake F=``
_3 inch Plumbing Vent through roof minimum 18 inches ',,,,';,
Roof Complete/Exterior Finish Complete x.
Platform at all exterior doors �.":f`
Handrail 4 or more risers i�,,-'
Guards at stairs, decks,patios more than 30 inches above grade ,,;,7 ;
Guard at stairwell at 34 inches or more ,�-"'-
_
Guard at deck,porches 36 inches or more V,n
Handrail Termination at Newell Post or Wall t./,
Interior/Exterior Railings 34 inches to 38 inches r,,, ,,
Deck Bracing/Handicapped Ramp Complianti
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate V7..
Gas Valve shut-off exposed/regulator 18 inches above grade ; . ---~- 1; i
Interior privacy/trim/doors/main entrance 36 inches ,,
Bathroom/Kitchen watertight _ .
Safety_glazing/Window in stairwells safety glazing _
Interior Smoke Detectors/Carbon Monoxide'Detectors
Every level: Every Bedroom:
Outside every bedroom area: -
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents , r r
Bathroom Fans, if no window .;7
Plumbing fixtures t7.-
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification - -- �_-0
Floor truss,draft stopping finished basement 1,000 sq.ft. ''
Emergency egress below grade - ~--
Gas Furnace shut-off within 30 feet or within line of site , _-, 1
Oil Furnace shut-off at entrance to furnace area Vi '' ( �- - 1M1 PA-C--
Furnace/Hot Water Heater operating may ,- .f. f `
Low water shut off boiler e,e ire
Relief Valves)installed/Heat Trap/Water Temp 110 a � -w-•- ----�---�,
Enclosed Stairs Sheetrock Underside minimum'/z"Gypsum 03:S _ (-4-A
Basement stairs closed rise>4 inches a 'e ' *F"-'41-1-7 r-.) f
Garage Floor Pitched ... - ) )� (�i'1Y 1"1J�1'C-`,;
Garage fireproofing/3/4 hour fire door I door closer1 `___. . . __W__ -.�._•_•• -.m•._m.,
Gas Logs in Sealed or Glass Enclosure tib."• �,. ,
Final Electrical; Energy Saving Light Bulbs 50% \/ / ' ( \ 'te a.
Final Survey Plot Plan / :,
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles V ., j- I •-L l "i j
Flex Gas Pipe Bonding q/°
As Built Septic System I Sewer Dept. Inspection Sticker ��' -- "' - '"+-
Site Plan /Variance required .--^ ,t .
Flood Plain Certification, if?squired, i j �/
Oki to issue C/C or C/•O[Temporari/Permanent] /
L:\Building&Codes Forms\Building&Codesllns-pection Forms1Residential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
Queensbury Building & Code Enforcement - Residential Final Insp ction a� --/Z)
Office No. (518) 761-8256 Arrive: am/pm Depart9 � Qm/pm
Date Inspection request received: Inspector's Initials:
NAME: ,S k7e.‘(\4:1 PERMIT#: /3-3 b3
LOCATION: 3 \ L �1( DATE: /c -- 0.- /X
TYPE OF STRUCTURE: S "r A
Comments:
Yes No N/A
4" Building Number Address visible from road 1/
Chimney Height/"B"Vent/Direct Vent Location t1 A
Fresh Air Intake icy "A.
3 inch Plumbing Vent through roof minimum 18 inches 1,. n�
Roof Complete/Exterior Finish Complete '.% c{.Q 14- -
Platform at all exterior doors a f (
Handrail 4 or more risers /
Guards at stairs, decks,patios more than 30 inches above grade V .. c
Guard at stairwell at 34 inches or more y/
Guard at deck,porches 36 inches or more �f — L* ) - " \.X 5
Handrail Termination at Newell Post or Wall ;//
Interior/Exterior Railings 34 inches to 38 inches Vim`-1�
Deck Bracing/Handicapped Ramp Compliant ' ✓/� �1�
Grade away from foundation 6 inches with 10 feet ,/ �- r �"r�' I
6 inch clearance to sill plate V/ Vc3 ?
Gas Valve shut-off exposed/regulator 18 inches above grade 1./,,,
p,� r
Interior privacy I trim I doors/main entrance 36 inches / 0 ' e f Z��LX)!`= Le.--
Bathroom/Kitchen watertight p/ + ?...
Safety glazing/Window in stairwells safety glazing 17
Interior Smoke Detectors/ry Carbon onoxi 6etectors `� -�
Every
f level: Eve Bed m: rr►�� �, t
Outside every bedroom ea: / (d>-
_ 4' 1
Inter Connected: Battery backup: �/ /Z-CD 1;
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area _ �/ r�
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents V/� t i' — r
Bathroom Fans,if no window t� --e. -
Plumbing fixtures 1� •
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly I Blower Door Test Certification i - - 4 WZ_5 a)
Floor truss,draft stopping finished basement 1,000 sq.ft. � V".
Emergency egress below grade Y/ Q.) t Vim,i -L . rx.`2-\!' .:
Gas Furnace shut-off within 30 feet or within line of site ✓ .
Oil Furnace shut-off at entrance to furnace area f � '
Furnace/Hot Water Heater operating V `x )--
' ,
Low water shut-off boiler / � " -�t2 L
Relief Valve(s)installed/Heat Trap/Water Temp 110 ►/
Enclosed Stairs Sheetrock Underside minimum IA"Gypsum Ar'
lir (�
Basement stairs closed rise>4 inches
Garage Floor Pitched z
Garage fireproofing/3/hour fire door/door loser
Gas Lo sin led or Glass Enclosure ,
final Electrical; Energy Saving Light Bulbs 50% :7;2 ---z--VIZ,c3-0.- 6-0�� `r-�
of Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex -. -'.- ;. .
_ - $ • i . - Sewer Dept. Inspection Sticker 4'
le • an / ariance required
••• - -in Certification, if rel u _' ;-/ ,
Okay to issue C I C or CTempoyPermanent]ri
L:1Building&Codes Forms\Building&CodeslInspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
'r [ do
Queensbury Building & Code Enforcement - Residential Fina Inspection
Office No. (518) 761-8256 Arrive: -7am/pm Depart -�"am/pm
Date Inspection request received: Inspector's Initials:
NAME: S h eeV\QY1 PERMIT#: /3-' 303
LOCATION: 3 i .g 1 re'.. DATE: 5. --.3/D --I-II
TYPE OF STRUCTURE: 6 i`'ID
Commentss-3 /039
Yes No N/A
4" Building Number Address visible from road N/ ��e\ ,�1 r
Chimney Height/"B"Vent/Direct Vent Location
Cik
Fresh Air Intake /' crr\ M S eit
3 inch Plumbing Vent through roof minimum 18 inches �/
Roof Complete/Exterior Finish Complete ‘.1' /
Platform at all exterior doors
Handrail 4 or more risers /
Guards at stairs,decks, patios more than 30 inches above grade ✓/ 0.` i�� -p�`
Guard at stairwell at 34 inches or more V.." v
Guard at deck,porches 36 inches or more ✓
Handrail Termination at Newell Post or Wall %/
Interior/Exterior Railings 34 inches to 38 inches v
Deck Bracing/Handicapped Ramp Compliant / 0/.4- 1, r:::-- --17.... ..�` .
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate /4/ - ` y!�.e-��
Gas Valve shut-off exposed/regulator 18 inches above grade V '.
Interior privacy/trim I doors 1 main entrance 36 inches
Bathroom/Kitchen watertight �, � rb S-1 ---
Safety glazing/Win ow in stairwells safety gl- 'ng t/.,�
Interior Smoke D ectors/Carbon M noxid .etectors C �`REvery level: Eve Bedr m. :_t_...// 1,'t JrOutside every bedroom ea:
Inter Connected: Battery backup: 7 +��, e -� ����-\ _ \t
Attic access 30 inches x 22 inches x 30 inches(height) n accessible area / / ' �(-- -IE ` �2\1
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq. . �/
Bathroom Fans,if no window +� il, 6, �-� , `,_ '��� �1
Plumbing fixtures 1-0 ��--i`� - l s!�
Foundation insulation to floor J Sticker on Panel
Duct work sealed properly I Blower Door Test Certification V k.LrA" Z't
Floor truss,draft stopping finished basement 1,000 sq.ft. / �Y �`" `-1 1--);--
Emergency egress below grade Y ./
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area Yd :S_%,:9 :iE
1- -ti,..A-y,-%
Furnace/Hot Water Heater operating v
Low water shut-off boiler / _ .0.- '‘Relief Valve(s)installed/Heat Trap/Water Temp 110 V
Enclosed Stairs Sheetrock Underside minimum W Gypsum VC.�'
Basement stairs closed rise>4 inches //
Garage Floor Pitched v/
Garage fireproofing/'/,hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure V
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic Sysct r Dept. Ins ction Sticker .01",j 4/
Site Plan /Varian re uir�
Flood Plain Certification, it required
' IP
Okay to issue C/C or C/O[Tempora
L:1Buiiding&Codes Forms\Building&Codesllnspection Forms1Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08;Revised 12/22/10, Revised 04/13/11
Town of Queensbury Building & Code Enforcement "Er I cicre_t 1— 3
Office No. (518) 761-8256
Septic Inspection Report
Inspection request received:
Name: 3\l cc='elna n Inspected on: 9—/
Location: 31 &rah Arrive: ''WM a.m. p.m.
Permit No.: / 3—3d 3 Inspector's Initials: 6
..-� Comments and/or diagram
Soil Type: 91 oa !Clay
Type of Water: Municipal/Well Water
Waterline separation distance ft. ( " _ _.( ,I
Well separation distance ft. � /n� ��C
Other wells: ft. ^�
Well Casing Length 50'+/- Y N N/A
[150'to well required if NO] &1&'1 (
Absorption Field: Total lengthft. �", LOZ
Length of each trench be-" ft. .c--------------
Depth
y
1 �
Depth of trenches 1 Z
Size of Stone ".1--
Seepage Pits: Number ?
Size: >
Stone Size:
Piping Size Type
Building to lank kihr
yr.15-C?4—t--t"-Z-1)
Tank to Distribution Box 3 X17
Ai t �I'l'`-3C
Distribution Box to Field I Pit / " Grr7
Opening Sealed: Y N -��J'�-
End Cap
Inlet/Outlet Pipes&Baffles Y N '---- ----)01 . i �� tof --1-IP''VI,lr
Manholes 12"or less below grade Y_N
[provide extension collar if Yes] _Y_N
Location/Separations
Foundation to tank ft. f ��./ v,Q
�'
Foundation to absorption ft. -
Separation of Pits ft.
Conforms as per Plot Plan Y
2
Engineer Report and As-Built Y IN
ETU Maintenance Contract provided Y_N
Location-c � �
on Property: ` —
Front Rear Left Side fight Side Middle Front Middle Rear
Front
System Use Status'
_
/Approved
Partial Approved and to be re-inspected, plea�caBuilding & Codes Office
Disapproved
Septic Inspection Report
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Ins 9ction request received:
Queensbury Building & Code Enforcement Arrive: ((' am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's I�titjals:
P- /3_
NAME: S cecL'I,\ PERMIT#:
LOCATION: r(ti,IN INSPECT ON:
TYPE OF STRUCTURE: Fb
C-CYri K(2 )nca,7 f)�
Y N N/A
Plumbing under slab
Rough Plumbing / Nail Plates (.3 {
Plumbing Vent/ Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check/ Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door /Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection_02 05 13
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: /A i 7 D am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: / J
NAME: PERMIT #: ZeD\ --
LOCATION: :0> 5 .'•-- r _ INSPECT ON:
TYPE OF STRUCTURE: ,= k)
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent 1 Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/chane of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation /Residential Check/Commercial Check1.1.2
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape
(Ze —
COMMENTS: V1/4
VE5(1--1-`0) ('‘) .
of f47."/(—
Rough
Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: k Q am/pm
742 Bay Road, Queensbury, NY 12804 Inspect ' fii als:
NAME: 5h fie-dty\ PERMIT#: 13--3493
LOCATION: 3 t. rte, Pzpt INSPECT ON: A-41—N
TYPE OF STRUCTURE: S F
p Qr1
Y N N/A a la Halo/
Plumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping 14)4—)C1/4.
Air/ Head
50 P.S.I. for for 15 minutes <c-°
Insulation / Residential Check/Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
c�
COMMENTS: � tiQSA.)1".qt-LoVj
}
icx t i t -5
Rough Plumbing_Insulation Inspection_02 05 13
wed °F II
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date In ection request received:
Oueensbury Building & Code Enforcement Arrive: 1'r' a /pm
742 Bay Road, Oueensbury, NY 12804 Inspect s Init als:
NAME: nS h e 6-\02-i' PERMIT#: / 3 -3 c,3
LOCATION: ,3 1 P 1 c'CAN INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Plumbing under slab
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check/Commercial Check -#4.21fr 1\} A
Window Sealing ►J` I�
Tyvek or Similar Exterior Sealant _
Proper Vent, Attic Vent
P
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection_02 05 13
Ge wc -n /01, 30 -4 i o / 2
Rough Plumbing I Insulation Insp e
Office No. (518) 761-8256 Date Inspection jgquest received: i --3/y
Queensbury Building & Code Enforcement Arrive: ! �r �.) ., /pm
742 Bay Road, Queensbury, NY 12804 Inspectors Initldls. ,_ :III
NAME: 5 \meal i l/\I PERMIT#: J 5 G
LOCATION: 3 I 6 i r' c4 itz-fAA, INSPECT ON: ZIti /
TYPE OF STRUCTURE:
Y N N/A
Plumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I. for for 15 minutes
sulation / Residential Check/Commercial Check
indow Sealing ft VA (
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace (,--V-.)
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection_02 05 13
IN\v , s 1
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Insp•ction r 'uest received:
Queensbury Building & Code Enforcement Arrive: 4- L am/pm
742 Bay Road, Queensbury, NY 12804 Inspect i res Irti is
NAME: Sh PERMIT#: / -3c3
LOCATION: 3 1 \reV. INSPECT ON: I U~/
TYPE OF STRUCTURE: 1Qs
ud*u0D r^K
Y N N/A
Plumbing under slab
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check/ Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace47?-- � ,,
Duct work sealed properly No duct tape C�
Blower Door Test `CMA-
Air Sealing 1V°11 .-1 --
COMMENTS:
Rough Plumbing_Insulation Inspection_02 05 13
T3c)-( 0
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: ' am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (� l
NAME: 31-kC-Q-kA PERMIT #: ? D l 3 - .-
LOCATION: 3vr'� R INSPECT ON: 2 M
TYPE OF STRUCTURE:
_
Vv.N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet I change of direction
Pressure Test /
l
Drain/Vent
Air/ Head �/ \x'
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head fir.
50 P.S.I for 15 minutes
Insulation I Residential Check I Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008
W42 S'.-7
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Ins ectign re est received:
Queensbury Building & Code Enforcement Arrive: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector' Initia s:
NAME: S 'C \ PERMIT#:
LOCATION: 3 I 6 [ 4<'4 INSPECT ON: /'y
TYPE OF STRUCTURE:
Y N N/A
Plumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent �--(
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head �✓� ' J
50 P.S.I. for for 15 minutes
Insulation /Residential Check/Commercial Check
Window Sealing CC- (
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS: b----v(z_c
Rough Plumbing_Insulation Inspection_02 05 13
T r c
Framing / Firestopping Inspection Repo
Office No. (518) 761-8256 Date Inspectionrequest received:
Queensbury Building & Code Enforcement Arrive am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's !nit als•
NAME: 3 c_e.1Acq. ) PERMIT#: / 3-30-2
LOCATION: 31 ,f 1166 Rd INSPECT ON:
TYPE OF STRUCTURE: S Fp
7 .,\147)
N/A COMMENTS:
Framing
Attic Access 22" xi0" minimum
Jack Studs / Headers
Truss Specification Provided - r • c-c —\t'\- - ✓ '
Bracing /Bridging •� �j () �tizl" c
Joist hangers
Jack Posts/ Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in. Vre--es-Q—,
Stairwells 36 in. or more "
Exterior Deck Bracing 1�
Headroom 6 ft. 8 in. �' -' c�T �
Notches/ Holes/Bearing Walls
Metal Strapping for Notches Top Plate
11/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice ans water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space / Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above /below grade
5.0 sf grade
Design Professional Sign-off, If required �Akk-"P - I
Framing Firestopping Inspection_Revised_02 05 13
(\(N"' Alat S -lam
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: ' am/pm
742 Bay Road, Queensbury, NY 12804 Inspector l iitials:�
NAME: PERMIT #: / 3-333
LOCATION: ••k d L'tJr x -. C ,N1 INSPECT ON: /— ) %'y
TYPE OF STRUCTURE: S
Y N N/A COMMENTS:
Framing
Attic Access 22" x..0" minimum
Jack Studs / Headers
Truss Specification Provided
Bracing / Bridging
Joist hangers
Jack Posts / Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches / Holes / Bearing Walls
Metal Strapping for Notches Top Plate
11/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
ice
ans water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space /Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above / below grade
5.0 sf grade
Design Professional Sign-off, If required
Framing Firestopping Inspection_Revised_02 05 13
---r u Esc e cS Q
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspectionrequest received:
Queensbury Building & Code Enforcement Arrive: `7 am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto nit als:
NAME: S h g6'�e v1 PERMIT#: /3-3v 3
LOCATION: I Bir 1 (P INSPECT ON: /—.;11-11
TYPE OF STRUCTURE: • S FP
Y N N/A COMMENTS:
Framing
Attic Access 22" x 20" minimum
Jack Studs /Headers `) 9/0, --34.0:3
Truss Specification Provided
Bracing /Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/ Holes /Bearing Walls
Metal Strapping for Notches Top Plate
11/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center /7.--?A‘ATiq-L
�..4.0 ans water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation e_,../ A, V—(512--
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space /Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above / below grade
5.0 sf grade
Design Professional Sign-off, If required
Framing Firestopping Inspectian_Revised_02 05 13
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: _amI Depa � am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initial 11,{ , I� )")
NAME: ! � �, ► PERMIT#: 2�i P)
LOCATION: h INSPECT ON: I 111 l l`\-
TYPE OF STRUCTURE: yf} l
Y N N/A COMMENTS:
Framing
Attic Access 22" x 30" minimum
Jack Studs/ Headers
Bracing /Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in. •
Notches/ Holes/ Bearing Walls
Metal Strapping for Notches Top Plate
1 % (w) 16 gauge (8) 160 nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Botts 6 ft. or less on center
Ice and water shield 24 inches from wall
A41.- ii
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins. • ion •quest received: /3/((
Queensbury Building & Code Enforcement Arrive: - am/pm
742 Bay Road, Queensbury, NY 12804 Inspector nit'.Is:
NAME: 51AeeU1, 14c\) PERMIT#: 13 /G
LOCATION: 'I 6(v2(i' 6k INSPECT ON: (1
TYPE OF STRUCTURE:
Y N N/A COMMENTS:
Framing
Attic Access 22" x 20" minimum
Jack Studs /Headers
Truss Specification Provided
Bracing /Bridging
Joist hangers
Jack Posts/ Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches / Holes / Bearing Walls
Metal Strapping for Notches Top Plate
11/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
( e ans water shield 24 inches from wall
ire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour V6rZ . k \;—
Firestopping 2'
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation � 1 �.�2
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space /Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above / below grade
5.0 sf grade
Design Professional Sign-off, If required
Framing Firestopping Inspection_Revised_02 0513
— OA
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Ins a tion re st received: //67/A7
Queensbury Building & Code Enforcement Arrive: ' a /pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Skee,G, 1/----)N1 PERMIT #: / 3-30'3
LOCATION: 3 1 G i ( C 4\ ( z INSPECT ON: 1/1 / `(
TYPE OF STRUCTURE: /
Y N N/A COMMENTS:
Framing
Attic Access 22" x 20" minimum
Jack Studs /Headers
Truss Specification Provided
Bracing / Bridging
Joist hangers
Jack Posts/ Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/ Holes/Bearing Walls
Metal Strapping for Notches Top Plate
11/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
nchor Bolts 6 ft. or less on center ��
ce anidwater shield 24 inches from wall ��- '—`
(-si_
Fire separation 1, 2, 3 hour 7-11-017_,—
Fire wall 2, 3, 4 hour r<_.V—>
FirestoppingC`"" —
Penetration sealed
16 inch insulation in cavity min. p`j . c. W—f-- . "�� (
Garage Fire Separation1 ' - t
House side 1/2 inch or 5/8 inch Type X t���`�� c `'—d
(
Garage side 5/8 inch Type X
Ceiling/wall 1-0
Windows Habitable Space /Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above / below grade
5.0 sf grade
Design Professional Sign-off, If required
Framing Firestopping Inspection_Revised_02 0513
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: 5 \-) 63. =_\-) c-N PERMIT#: / 3-,je)
LOCATION: ;), ( f i eV) INSPECT ON: // / -
TYPE OF STRUCTURE: _r ,h
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
✓ Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspectlon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
1,\1DivAck
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart: pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ��-�
NAME: S \ND( 1,A-(11_,i\- , PERMIT#: / - _
LOCATION: -?i / �rc,h INSPECT ON: 13,
TYPE OF STRUCTURE:
Comment,
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. _
Foundation/Wallpour
f2C5-07__
Reinforcement in Place
Footing Dowels or Keyway in place �t
Foundation Dampproofmg �, q
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspectlon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
rct1 -3 ..
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:/uk)
i , am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: ;3 k1 C N_\(16 d1 PERMIT#: / 3
LOCATION: 31 (3 u;o1NRezi INSPECT ON: /o
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
(C1 Foundation Dampproofing
Foundation Waterproofing ^ �
ti-
Footing Drain Daylight or Sump c *Stk-•f _ _
Footing Drain Stone:
12 inch width + - RD "--k` 64C4)tiL
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab J�
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Bullding&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:bt,..A9
NAME: S h C'f b\cct PERMIT#: / 3 a o.-
LOCATION: 24 el. L164 INSPECT ON: /0—a
TYPE OF STRUCTURE:
Comments
Y N L
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundationsulation Leri /Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Buiiding&Codes\1nspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
M anAc~<
Foundation Inspection Report T " I D
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart , am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: z—
NAME: S P e Ih(v) PERMIT#: /3 .3 23
LOCATION: (3 . INSPECT ON: //7 - .
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbingr '
Under Slab S
�P\ /Cast/Copper
Foundation InsulatiInti r'/Exterior V
R- d
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Reportfo
C' i d c
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:/ } pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials'
(
NAME: 3 e L‘w) PERMIT#: / 3 -3E73
LOCATION: X3) A i ~<� , INSPECT ON: /O JO-/3
TYPE OF STRUCTURE: Sr b
Comments
Y N N/A
.V Footings ,
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place f
Footing Dowels or Keyway in place \J,� /mac '
v�
Foundation Dampproofmg 4\
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inion Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Z (Rou h Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspecti re uest received: /U/I c s
Queensbury Building & Code Enforcement Arrive: r am pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initi s:
-'r 'V'
NAME: PERMIT#: v
LOCATION: -271 i3, (d r INSPECT ON: /0/ /5(3
TYPE OF STRUCTURE: CW-317
Y N N/A
Plumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I. for for 15 minutes
' Insulation /Residential Check/Commercial Check jc r`u.x t
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection_02 05 13
Foundation 11I
on Inspection Report
Office No.(518)761-8256 Date Inspecti n est received:
Queensbury Building&Code Enforcement Arrive: pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector s 'tial •
NAME: l'? ' } PERMIT#: / 3 '3
LOCATION: l v',- c. / le 6 INSPECT ON: I i)f I s/l 3
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm
�� Depart —am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:c
NAME: PERMIT#: 2 CA:)—?-.A7-7
LOCATION: :Q! �c) INSPECT ON: I l
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Baclll Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Buiiding&Codes Forms\Building&Codes\Inspection Forms\Foundatlon Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received: l b I /1 /3
Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:6424)
NAME: c1-v.N.\ PERMIT#: /3". 3°3
LOCATION: Ya-at ( A INSPECT ON: 10
TYPE OF STRUCTURE: � � T
Comments
Y N N/A '
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place 'l
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
ackfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Buliding&Codes Forms\Building&Codes\Inspectlon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
LOOA of.c;
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:/ am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: G
NAME: , h E.N‘'NQ frA PERMIT#: / 3- a C%.3
LOCATION: , '�,—N� AV INSPECT ON: /D -/.3
TYPE OF STRUCTURE: G, iz n
Comments
Y N NA
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. _
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place OiS
Foundation Dampproofmg
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Fomns\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Lc) 1-3
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials s.a)
p
NAME: S \-1E1(-2k '\ PERMIT#: 1.3—3(.7)
LOCATION: , j reAN Reit INSPECT ON: .
TYPE OF STRUCTURE:
Comments
Footings NL
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour r PLJ
Reinforcement in Place
11/7:
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Buliding&Codes Forms\Bullding&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
J
PHINNEY DESIGN GROUP r"- -1
Architecture / Interior Design / Environmental Design
142 Grand Avenue Saratoga Springs, NY 12866 ph: 518-587-7120/fx: 518-587-7250
PHINNEY
DESIGN GROUP
2013
Date: July 10, 2013
To: Town of Queensbury Building and Codes Department
742 Bay Road
Queensbury,NY 12804
Ph,518 761-8256
Fax 518 745-4437
Project Sheehan Residence
31 Birch Road
Queensbury, NY 12804
Project No.: 13100
LETTER OF TRANSMITTAL
One (1) Original: Building Permit Application Dated 07/08/2013,
Completed and signed.
One (1)Original: REScheck Compliance Certificate,Prepared by Phinnf
Design Group, dated 07/09/2013,signed and sealed.
One (1) Original: Fuel burning appliance and chimney application
Completed.
One (1) Original: Septic application Completed and signed.
One(1)Original: Checklist for single family.
Two (2)Copies:
(24x36) drawing sets: Plot Plan Prepared by Hutchins Engineering,dated
09/18/2012,revised 06/05/2013,signed and sealed
Two (2) Originals of:
(24x36) drawing sets: Drawing List:
Name
A0.0 Cover Sheet
X1.1 Site Plan
A1.0 Lower Level Floor Plan
A1.1 Main Level FIoor Plan
-
Page 2
A2.1 Roof Plan
A2.2 Roof Details 07-08-1307-08-13
708-1307-08-13
A2.3 Truss Profiles
07-08-13
A3.1 Exterior Elevations
07-08-13
A3.2 Exterior Elevations
07-08-13
A4.1 Building Section
07-08-13
A4.2 Building Sections
07-08-13
A4.3 Building Sections
07-08-13
A4.4 Building Sections
07-08-13
A4.5
Wall Sections 07-08-13
A4.6 Wall Sections 07-08-13
A5.1 Window Schedule 07-08-13
Prepared by Phinney Design Group,signed and sealed.
S0.1 General Notes 07-08-13
S1.0 Foundation Plan 07-08-13
S1.1 First Floor Framing Plan 07-08-13
S1.2 Roof Framing PIan 07-08-13
S2.0 Foundation Sections 07-08-13
S2.1 Foundation Sections 07-08-13
S3.0 Framing Sections 07-08-13
S4.0 Typical Details 07-08-13
S4.1 Typical Details 07-08-13
Prepared by Siracuse Engineers PC,signed and sealed.
To whom it may concern,
Please see the attached documents for Building Permit submission. Please let me know if
you have any questions,or need any additional information. Thank you.
Daina Peppin
PHINNEY DESIGN GROUP
142 Grand Avenue
Saratoga Springs, NY 12866
Tel:. 518.587.7120 x 15
Fax:.518.587.7250
phinneydesign.com
al\&dem exy july 11,2013)
1