2013-485 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20130485 Date Issued: Wednesday, November 20, 2013 This is to certify that work requested to be done as shown by Permit Number P20130485 has been completed. Tax Map Number: 523400-309-009-0002-001-000-0000 Location: 200 LUZERNE Rd Owner: HOMESTEAD VILLAGE L P Applicant: SANITARY SEWER This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY (TD j4,ct Issuance of this Certificate of Compliance DOES NOT relieve the 4 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building& Code Enforcement Planning Board or Zoning Board of Appeals. Oek TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130485 Application Number: A20130485 Tax Map No: 523400-309-009-0002-001-000-0000 Permission is hereby granted to: SANITARY SEWER For property located at: 200 LUZERNE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HOMESTEAD VILLAGE L P 4294 ROUTE 5 Septic Alteration Residential CALEDONIA,NY 14423 Total value Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2013-485 5 & 6 Windsong Res/Septic Alteration $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, October 16,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Que sbu 141 W, •, e 1� ., . I ctober 16,2013 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Community Development Office Town of Queensbury - 742 Bay Road • Queensbury, New York -12804 OCT 15 71113 Office Use Only g 6 TAX MAP NO. 9 c `'' PERMIT No. j5 PERMIT FEE APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPL I CATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: /4�'71 S t INSTALLER: c--5;91V/ �iY�tr�]�c✓c'/Z ��i k ' P ADDRESS: '?"'ZZ /- C�}�sT � ADDRESS::.- /J C' Z2Y 4/`"^'-1 / "./7-J PHONE NOS. PHONE NOS. -576---2Z `72X LOCATION OF INSTALLATION:(Of S-5. G Pt '`�S'/(' f� t U/,� RESIDENCE INFORMATION: YEAR BUILT NO.OF X COMPUTATION = TOTAL DAILY FLOW BEDROOMS (Gallons per bedroom) GARBAGE GRINDER 1980 or older X 150 = INSTALLED? 1981 -1991 X 130 = SPA OR HOT TUB 1992-present X 110 = INSTALLED? PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLINg STEEP SLOPE %SLOPE ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is: ft) ✓ PERCOLATION TEST: RATE IS PER MINUTE PER INCH[mpi] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE:"" /OP GALLON(MIN.SIZE IS 1,000 GAL.)Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: fBSORPTION FIELD(WITH NO.2 STONE) Total length 2s r/ ft. Each trench X ❑SEEPAGE PIT(S)(WITH NO.3 STONE) How many? Size? ❑ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury QUESTIONS? CALL 7614256 OR EMAIL Sanitary Sewage Disposal Ordinance. codes(a.nueensburv.net Signat e % Person Responsible Date VISIT OUR WEBSITE FOR MORE INFORMATION www.oueensbury.net Septic Inspection Report Office No. (518) 761-8256 Date Inspection =• -•i ived: Queensbury Building &Code Enforcement Arrive:' - _ . 01., i- •.rt: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial-WS NAME: \--\Oijk E\5T�C ) \C1L E P' ' IT NO.: 13 —L\ --- LOCATION: '541(0 13,11ky) cn () d :PECT ON: i I "1"i"1 2) RECHECK: Comments and/or diagram Soil Type: Sand / Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + / - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench ft. Depth of trenches Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box __ _ Distribution Box to Field / Pit Opening Sealed: Y_N End Cap _Y N Inlet/Outlet Pipes&Baffles Y_„_,•N Manholes 12"or less below grade _Y N [provide extension collar if Yes] _Y N Location/ Separations Foundation to tank ft Foundation to absorption -. itoSeparation of Pits l • . Conforms as per Plot Plan i N Engineer Report and As-Buil r T N ETU Maintenance Contract _Y_ N provided I Location of System on Property: Front ear Left Side Right Side Middle Front Middle Rear S stem Use S tus: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Fors\Inspection Forms\Septic Inspection Report 03 29 10.doc pllll►IIIIIII �� IIIIIIIIIIII ; ENVIRONMENTAL DESIGN PARTNERSHIP, LLP November 16, 2013 Queensbury Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Attn: John O'Brien Re: Homestead Village Mobile Home Park Lots 5 & 6 Windsong Dear John: On November 6, 2013 our office inspected the above referenced Homestead Village Mobile Home Park lots. The purpose of this visit was to observe the installation of the new septic system designed by EDP dated November, 2013. Based on my review of the plans and observation of the installation it is my opinion that the system was installed substantially in compliance with the intent of the design plans. However, due to special constraints the configuration of the lines was modified as shown on the attached as-built plan. Please contact me should you have any questions regarding this system. Sincerely, 1(:7,P01.0 James E. Mitchell, P.E. 900 Route 146, Clifton Park, New York 12065 phone (518) 371-7621 -fax(518) 371-9540 • LEGEND: WS. DENOTES WATER SHUTOFF NOTE: 1) BASEMAP INFORMATION OBTAINED FROM PUBLICALLY AVAILABLE RESOURCES AND DOES NOT REPRESENT AN ACTUAL FIELD INSTRUMENT SURVEY. J N CONCLA. PAD x w I PARKING U AREA W W 3 AS—BUILT 1,000 GALLON SEPTIC TANK AS—BUILT 4" PVC SCH 40 AT 2% MIN. E N C E r< \ i� LOT 7 PARKING AREA EXISTING MOBILE HOME AS—BUILT WYE AND 4" PVC SDR —35 (GASKETED BELL) AT 1% MIN. AS—BUILT 1,000 GALLON SEPTIC TANK AS—BUILT 4" PVC SCH 40 AT 2% MIN. 1 EX. SHED I I I I I I AS -BUILT EXIS77NG DISTRIBUTION BUTION BOX #2 MOBILE HOME I I I I I i o Q. I I I I I I I I U PARKING AREA W. S. WIN SONG =� LOT 5 PARKING AREA DRI VE >I � RI W 3 ti AS—BUILT ABSORPTION FIELD 3 LINES AT 55 FT. AND 2 LINES AT 50 FT. EACH TO SERVICE BOTH LOTS 5 & 6 EXISTING MOBILE HOME BORING AND PERCOLATION TEST: ASSUMED CONDITION BASED ON SITE EVALUATION 0-5' MEDIUM FINE SAND NO WATER OR MOTTLING PERCOLATION RATE APPROXIMATELY ONE MINUTE NOTE: SOIL CONDITIONS TO BE CONFIRMED BY P.E. PRIOR TO BACKFILLING SYSTEM. SEPTIC DESIGN: APPLICATION RATE = 1.2 GAL./SF/DAY LOT 5 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS LOT 6 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS TOL 6 BEDROOMS AT 100 GALLONS/BEDROOM = 600 GALLONS USE (2) 1,000 GALLON PRECAST SEPTIC TANKS USE 5 LINES AT 50 FT. EACH (SPACED 6 FT. ON—CENTER) TOkf\IN OF QU'`. PUILDINIG A Review Date: __ AS -BUILT SEPTIC REHABILI TA TION PREPARED FOR L O T 5& 6 WINDSONG DRI VE � 3 -4S'5- HOMESTEAD VILLAGE TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK SCALE: 1 " = 20' NOVEMBER 11, 2013 ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 ENGINFEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E MITCHELL P.E. 53,337 no 2 CIL Q LLgJ '-3PM Septic Inspection Report Office No. (518) 761-8256 Date Ins on reque- =iv;.: Queensbury Building &Code Enforcement Arrive: P 3t a D:.art: ..-•!; a pm 742 Bay Rd., Queensbury, NY 12804 Inspecto s Initials: `_ NAME: /IT eS `�- ?€t C PE 7IT NO.: / 3 -<875 LOCATION: 3 c+ Up AI. I PECT ON: /1 RECHECK: Comments and/or diagram Soil Type.= .am / Clay Type of Water: • unici ell Water Waterlin- -paration distance l0 ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] Absorption Field: Total length _ ft. Length of each trench -'eg% c= "t,ft. Depth of trenches Zr- ft. Size of Stone �rZ Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank L-1,. _ A, y� Tank to Distribution Box y" k) -7h Distribution Box to Field/ Pit \-j" h0C- -7,9 TO `--1,'' h0 R -23 CS- Opening Sealed: N End Cap N Inlet/Outlet Pipes&Baffles Manholes 12"or less below grade _Y_N [provide extension collar if Yes] Y N --- Location / Separations M Foundation to tank 5 , , ft. A_ Foundation to absorptionft. Separation of Pits Conforms as per Plot Plan Y Engineer Report and As-Built _Y^ N ETU Maintenance Contract _Y N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status' (\(TO R,NF1LL Approved • Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc INSPECTION REQUIREMENTS: ENGINEER OF RECORD TO INSPECT TRENCHE=S PRIOR TO BACKFILLING. NOTE: 7) BASEMAP INFORMATION OBTAINED FROM PUBLICALLY AVAI_ AHI F RESOURCES AND DOES NOT REPRESENT AN ACTUAL FI__L INSTRUMENT SURVEY_ REMOVE EXISTING TREES AS NECESSARY PROPOSED 1,000 GALLON SEPTIC TANK (SEE DETAIL — SHEET 2) - PROPOSED 4" PVC SCH 40 AT 2% MU FEN C E�� EXISTING MOBILE HOME CONC. PAD PARKING AREA LOT 7 PARKING AREA CONTRACTOR MUST CONFIRM LOCATION OF EXISTING WATER SERVICE PRIOR TO COMMENCEMENT OF CONSTRUCTION AND MAINTAIN A MINIMUM 10 FT. SEPARATION BETWEEN THE EXISTING WATER SERVICE AND PROPOSED SANITARY SEWER LATERALS NOTE: 1 1 1 LOT 6 AREA I WI ND SON U ti U WOW SI mp�n � Oa° � o00 til ti�G 3 UPJ OQ V2° ° EXISTING SANITARY STRUCTURES INCLUDING SEPTIC TANK AND SEEPAGE h'1 DEVICES ARE TO BE CRUSHED IN PLACE \ AND FILLED WITH NATIVE MATERIAL. I` F � J \ ui U W Q l oU�� t Q PROPOSED WYE AND 4" PVC SDR z o d o —35 (GASKETED BELL) AT 1% MIN. QZ ¢ LL a w ww= H >w> PROPOSED 1,000 GALLON SEPTIC O ~ o TANK (SEE DETAIL — SHEET 2) d m J w U 0�Sv F- opo EXISTING SHED TO BE RELOCATED w <<'-'„ w rn zC)=o wOF's w >¢ = U Ru z PROPOSED 4" PVC —�� f__ SCH 40 AT 2% MIN. EXISTING MOBILE HOME LOT 5 W S. EX SHED PROPOSED DISTRIBUTION BOX #2 (SEE [DETAIL — SHEET 2) PARKING AREA DRI VE FENCE TO BE REMOVED AND REINSTALLED IN PLACE AFTER CONSTRUCTION IS COMPLETED. PROPOSED ABSORPTION FIELD 5 LINES AT 50 FT. EACH TO SERVICE BOTH LOTS 5 & 6 (SEE DETAIL — SHEET 2) MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION. THE LOCATION OF THE WATER SERVICE MUST BE VERIFIED PRIOR TO CONSTRUCTION TO CONFIRM PROPER SEPARATION DISATNCE FROM TILE FIELD (MINIMUM 10 FEET) EXISTING MOBILE HOME BORING AND PERCOLATION TEST: ASSUMED CONDITION BASED ON SITE EVALUATION 0-5' MEDIUM FINE SAND NO WATER OR MOTTLING PERCOLATION RATE APPROXIMATELY ONE MINUTE NOTE: SOIL CONDITIONS TO BE CONFIRMED BY P.E. PRIOR TO BACKFILLING SYSTEM. SEPTIC DESIGN: APPLICATION RATE = 1.2 GAL./SF/DAY LOT 5 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS IF QUEENSBURY G DEPARTMENT A examination; compliance s shall not be construed as Is and specifications are it lith the Building Codes o LOT 6 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS TOTAL 6 BEDROOMS AT 100 GALLONS/BEDROOM = 600 GALLONS USE (2) 1,000 GALLON PRECAST SEPTIC TANKS USE 4 LINES AT 63 FT. EACH (SPACED 6 FT. ON—CENTER) CONSTE?UCT/ON NOTES, 1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FROZEN OR THE SOIL MOISTURE CONTENT IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMA7EL ) NINE INCHES BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE M0I2TURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY MUST BE PRESENT FOR A RIBBON TO BE FORMED. 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (l. E, SETTLE NATURALLY FOR A PERIOD OF AT LEAST SIX MONTHS, INCLUDING AT LEAST ONE FREEZE—THAW CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE DESIGNATED ABSORPTION SYSTEM AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH CAVE—IN AND DISTRIBUTION PIPE MISALIGNMENTIBREAKAGE. 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN_ TRENCH DEPTH SHALL BE AS SHALLOW AS POSERLE, BUT NOT LESS THAN 18 INCHES, TRENCHES SHALL BE EXCAVATED TO W TH- BO-TT-0MS PRA.CS/CALL Y LEVEL - 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF THE TRENCHES SHOULD BE CHECKED BY A TRANSIT ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO ASSURE THAT EACH IS PRACTICALLY LEVEL. TRENCH BOTTOMS AND SIDEWALLS SHOULD BE IMMEDIATELY RAKED AFTER FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED IN THE TRENCHES. 5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY INSTALLED AT A SLOPE OF %s TO Y32 INCH PER FOOT. PRESSURE OR DOSED DISTRIBUTOR PIPE SHALL BE INSTALLED LEVEL. GRADES SHALL BE DETERMINED BY AN ENGINEER'S LEVEL, TRANSIT OR CARPENTER'S LEVEL. AN EASY METHOD OF MEASURING THE %6 INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A Y4 INCH BLOCK TO ONE END OF A STRAIGHT FOUR FOOT BOARD. BY PLACING THE BLOCKED END WITH THE BLOCK FACING DOWN ON THE DOWNSTREAM TOP OF THE DISTRIBUTOR PIPE, A CARPENTER'S LEVEL CAN BE USED TO DETERMINE THE Y16 /NCH PER FOOT SLOPE A Ye INCH BLOCK SIMILARLY USED WOULD REBJLT IN A %32 INCH PER FOOT SLOPE. ANOTHER METHOD USED TO ESTABLISH THE GRADE OF Dl i,AIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL BE INSTALLED IN THE TRENCHES TO ( A DEPTH OF AT LEAST TWO INCHES ABOVE THE TOP OF THE DISTRIBUTOR PIPES. ADDITIONAL AGGREGATE MAY BE REQUIRED TO BRING THE TOP OF THE AGGREGATE TO WITHIN SIX TO 12 INCHES OF FINAL GRADE. 6) AFTER THE UPPER AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE, UNTREATED BUILDING PAPER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AND THE TRENCH �y p�g+f� L r,t BACKFILLED WITH EXCAVATED SOIL. IF THE TRENCHES CANNOT BE IMMEDIATELY BACKFILLED, THE ,i OF QUEENSIBUR: [ UILDINGSPAPER LDTO PREVENT BE ORSIDEWALL COLLAPSE AND SILTATION ARILY COVERED WITH AN SINTO TTHE AGGREGAERIAL, SUCH ATE. TREATED 't & CO ES `7PT THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THE ORIGINAL GROUND LEVEL (I.E., NOT . COMPACTED) TO ALLOW FOR SETTLING. FOLLOWING SETTLEMENT, THE ENTIRE AREA SHOULD BE GRADED WITHOUT THE USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT SHALL NOT ENTER THE ABSORPTION FACILITY AREA OR THE PROPOSED EXPANSION AREA AFTER THE SUBSURFACE SEWAGE TREATMENT SYSTEM HAS BEEN CONSTRUCTED. w 8) A MINIMUM HORIZONTAL SEPARATION OF 10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND Q ANY WATERLINE. WHERE LINES MUST CROSS, THE WATER SERVICE LINE SHALL BE AT LEAST 72 INCHES ABOVE THE HOUSE SEWER. IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER, THE VERTICAL SEPARATION MUST BE AT LEAST 18 INCHES. kk 9) ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE SYSTEM. WATER SOFTENER, WATER RECHARGE AND BACKWASH WASTES NORMALLY ARE NOT TO BE DISCHARGED TO THE SYSTEM UNLESS A SEPARATE SUBSURFACE DISCHARGE TO AN AREA 250 FEET FROM WELLS OR WATER COURSES IS UNAVAILABLE. CONTRACTOR MUST CONFIRM / LOCATION OF EXISTING WATER SERVICE PRIOR TO SHEET 1 OF 2 COMMENCEMENT SEPTIC DESIGN PREPARED FOR CONSTRUCTION AND MAINTAIN A MINIMUM 10 FT. SEPARATION BETWEEN THE EXISTING WATER SERVICES AND PROPOSED LOT 5 & 6 WINDSONG DRIVE SANITARY SEWER LATERALS HOMESTEAD VILLAGE TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK SCALE: 1 " = 20' OCTOBER 3, 2013 ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MITCHELL P.E. 53,337 c Z OL WHERE TRENCH SHIELD IS USED .- - WITH THE APPROVAL OF THE ENGINEER, SHEETED TRENCH PAYMENT LIMITS WILL APPLY. 1 ALL BACKFILL MATERIAL TO BE PLACED IN 8" LIFTS AND BE COMPACTED TO 95% STANDARD PROCTOR (ASTM D698) DEBRIS, FROZEN MATERIAL, LARGE \ CLODS OR STONES, ORGANIC MATTER, OR OTHER UNSUITABLE MATERIALS SHALL NOT BE USED AS BACKFILL. SELECTED GRANULAR FILL PLACED IN 6" LIFTS AND MECHANICALLY TAMPED OR�`l A. 0. B. E. SEE NOTES 1&2. CRUSHED STONE OR SELECT GRANULAR MATERIAL AS ORDERED BY ENGINEER (MECHANICALLY -{— — TAMA.O.B.E. SEE NOTE 2._____ I I �- 6'" MIN, FOR PIPE 12" DIA. AND SMALLER FOR UNSTNST ABLL E TRENCH BOTTOM USE ------ ILJI ADDITIONAL DEPTH OF STONE AS I 12" MIN. FOR PIPE 14" DIA. AND LARGER NECESSARY TO PROVIDE A FIRM - (- FOUNDATION. NAT EXCAVATED GRANULAR MATERIAL USED IF APPROVED BY THE R. TRENCH DETAIL SELECTED GRANULAR FILL TO BE PLACED UNDER PAVEMENT TRENCH SLOPES ARE GIVEN FOR MAX. PAYMENT LIMITS ONLY FOR 3 PEN CUT AND ARE NOT INTENDED 3 /TO REPRESENT STABLE SLOPES UNDER FIELD CONDITIONS. ENT OR AL GROUND A.O.B.E. = AS ORDERED BY ENGINEER NOTE. CONTRACTORS MUST COMPLY WITH ALL LOCAL, STATE, & FEDERAL SAFETY REGULATIONS. (OSHA & N.Y.S. D.O.T.) NOT INTENDED TO REPRESENT A SAFE SLOPE 6"' WIDE GREEN PLASTIC LOCATOR TAPE, MARKED 'CAUTION SEWER BELOW" _TRACER WIRE #8 THING STRANDED COPPER OR STAINLESS STEEL 2" THICK RIGID POLYSTYRENE INSULATION A LOCATIONS WITH LESS THAN 4' COVER). EXTEND TO MIN, 4' BELOW GRADE. NOTES: 1) NA MAY BE ENGINE WHERE A WATER TABLE CONDITION EXISTS STONE BEDDING SHALL BE WRAPPED IN A ON -WOVEN GEO-TEXTILE ENVELOPE (FABRIC EQUIVALENT TO AMOCO 4545) 2) CRUSHED STONE NOT TO EXCEED #2 IN SIZE GRANULAR FILL TO MEET THE FOLLOWING REQUIREMENTS: 0 % IN EXCESS OF 3" 25 %-7� % PASSING #4 SIEVE o %-1st PAsswc #20o SIEVE NOT TO SCALE HEAVY DUTY MANHOLE FRAME FINISH GRADE /--AND COVER BY CAMPBELL OR EQUAL ASPHALTIC III = �� (MEREQDE RINGS) -IIII NEXTENSIN SEAL == —= 2 LD. AS PER FORT MILLER OR EQUAL (AS D) INLET 4 OR BLDG. SEWER SANITARY— TEE ALL JOINTS BELOW LIQUID LEVEL TO BE WATERTIGHT AND LEAKAGE TESTED PRIOR TO BACKFILLING ASPHALTIC SEAL INLET H THE SLOPE OF THE INLET PIPE BETWEEN THE RESIDENTIAL UNIT AND THE SEPTIC TANK TO BE Ya' PER FT. 3" MIN.- EriI 1 1/3 z —= A 2 H z d FULL 4" MIN. '- BITUMINOUS � o INTERIOR - o COAT Q NOR 300M c7 BAFFLE WITH OR EQUAL :J 4"X18' MIN - MAY NOT BE SECTION VIEW NOTE: INLET INVERT IS 3" ABOVE (2" MIN.) BAFFLE MAY NOT BE aenuiR G.. PLAN VIEW OUTLET s - WATER TIGHT JOINT (TYP.) PARSE W/NON-SHRINK GRO T INSIDE & OUT SANITARY TEE ..0, 6"' TO 12" LAYER PEA GRAVEL OR CRUSHED STONE BEDDING LAYER 24" I.D. TAPERED PLUG (TYP.) THE SLOPE OF THE OUTLET PIPE BETWEEN THE SEPTIC TANK AND THE DISTRIBUTION BOX TO BE Ya"" PER FT. 0] OUTLET NOTE: BAFFLE NOT REQUIRED FOR TANKS LESS THAN 10 FT. LENGTH TANK SIZE MIN. LIQUID DEPTH 'A" 1000 GAL. ' � O" TANK DIMENSIONS "B"X"C" "O" —1111— HEIS HT 4'-3" x 8'-2" -1111—IIII,- 5'-91" 1. PIPE JOINTS TO BE SEALED WITH =1111=IIII ASPHALTIC MATERIALS OR EQUIVALENT. TERRATEX N0. 2 NONWOVEN z a 2 INVERT ELEVATIONS OF ALL —11110 —� J. THE SLOPE OF OUTLET PIPES CONSTRUCTION FABRIC OR - : AC BETWEEN THE DISTRIBUTION BOX -— TREATE BUILDING PAPER BACKFILL - BACKFILL OR SHOULD BE I/8" PER FOOT. �� Illi IIII I—IIII- (�—Illi= —IIII TOP OF AGGREGATE ��� OO 00 INVERT _ = — 00 OC 4° PVC MIN - EX TO BE WITHIN 6"-12'" OF SURFACE g O RAKE ANY PERFORATION JOINT OUTLET CONTRACTOR TO USE SPEED LEVELERS SMEARED V AS SUPPLIcD BY FORT MILLER TO TRENCH EQUALIZE FLOW. N z OO (/��(J WALLS✓/%�////�j [/�)�. /�//�//]/� NOT TO SCALE 00 00 ✓ O 7 24" -� CRUSHED STONE OR 24' MIN GROUNDWATER BEDROCK WASHED GRAVEL OR IMPERVIOUS LAYER 3/>' TO 1Y2'' CROSS SECTIONAL VIEW LONGITUDINAL VIEW TERRATEX NO. 2 NONWOVEN CONSTRUCTION FABRIC UNTREATED BUILDING PAPER Ort PERMEABLE GEOTEXTILE OR 4" LAYER OF STRAW IIIIII—I�1 —IIII—I l f =IIII— - Oa O C7 ® a� 00 0 00 MIN. G� 2" a FLOWPROVIDE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CAPS ON LINE ENDS `G 00 Cf7 �� r OO O SLOPE PIPE Ye" -Yu PER FT, SPACING OF ABSORPTION TRENCH 6" 0, - TRENCH BOTTOM TO BE NEAR LEVEL AND RAKED TRENCH PROFILE ABSORPTION TRENCH DETAIL NOT TO SCALE WHERE TRENCH SHIELD IS USED .- - WITH THE APPROVAL OF THE ENGINEER, SHEETED TRENCH PAYMENT LIMITS WILL APPLY. 1 ALL BACKFILL MATERIAL TO BE PLACED IN 8" LIFTS AND BE COMPACTED TO 95% STANDARD PROCTOR (ASTM D698) DEBRIS, FROZEN MATERIAL, LARGE \ CLODS OR STONES, ORGANIC MATTER, OR OTHER UNSUITABLE MATERIALS SHALL NOT BE USED AS BACKFILL. SELECTED GRANULAR FILL PLACED IN 6" LIFTS AND MECHANICALLY TAMPED OR�`l A. 0. B. E. SEE NOTES 1&2. CRUSHED STONE OR SELECT GRANULAR MATERIAL AS ORDERED BY ENGINEER (MECHANICALLY -{— — TAMA.O.B.E. SEE NOTE 2._____ I I �- 6'" MIN, FOR PIPE 12" DIA. AND SMALLER FOR UNSTNST ABLL E TRENCH BOTTOM USE ------ ILJI ADDITIONAL DEPTH OF STONE AS I 12" MIN. FOR PIPE 14" DIA. AND LARGER NECESSARY TO PROVIDE A FIRM - (- FOUNDATION. NAT EXCAVATED GRANULAR MATERIAL USED IF APPROVED BY THE R. TRENCH DETAIL SELECTED GRANULAR FILL TO BE PLACED UNDER PAVEMENT TRENCH SLOPES ARE GIVEN FOR MAX. PAYMENT LIMITS ONLY FOR 3 PEN CUT AND ARE NOT INTENDED 3 /TO REPRESENT STABLE SLOPES UNDER FIELD CONDITIONS. ENT OR AL GROUND A.O.B.E. = AS ORDERED BY ENGINEER NOTE. CONTRACTORS MUST COMPLY WITH ALL LOCAL, STATE, & FEDERAL SAFETY REGULATIONS. (OSHA & N.Y.S. D.O.T.) NOT INTENDED TO REPRESENT A SAFE SLOPE 6"' WIDE GREEN PLASTIC LOCATOR TAPE, MARKED 'CAUTION SEWER BELOW" _TRACER WIRE #8 THING STRANDED COPPER OR STAINLESS STEEL 2" THICK RIGID POLYSTYRENE INSULATION A LOCATIONS WITH LESS THAN 4' COVER). EXTEND TO MIN, 4' BELOW GRADE. NOTES: 1) NA MAY BE ENGINE WHERE A WATER TABLE CONDITION EXISTS STONE BEDDING SHALL BE WRAPPED IN A ON -WOVEN GEO-TEXTILE ENVELOPE (FABRIC EQUIVALENT TO AMOCO 4545) 2) CRUSHED STONE NOT TO EXCEED #2 IN SIZE GRANULAR FILL TO MEET THE FOLLOWING REQUIREMENTS: 0 % IN EXCESS OF 3" 25 %-7� % PASSING #4 SIEVE o %-1st PAsswc #20o SIEVE NOT TO SCALE HEAVY DUTY MANHOLE FRAME FINISH GRADE /--AND COVER BY CAMPBELL OR EQUAL ASPHALTIC III = �� (MEREQDE RINGS) -IIII NEXTENSIN SEAL == —= 2 LD. AS PER FORT MILLER OR EQUAL (AS D) INLET 4 OR BLDG. SEWER SANITARY— TEE ALL JOINTS BELOW LIQUID LEVEL TO BE WATERTIGHT AND LEAKAGE TESTED PRIOR TO BACKFILLING ASPHALTIC SEAL INLET H THE SLOPE OF THE INLET PIPE BETWEEN THE RESIDENTIAL UNIT AND THE SEPTIC TANK TO BE Ya' PER FT. 3" MIN.- EriI 1 1/3 z —= A 2 H z d FULL 4" MIN. '- BITUMINOUS � o INTERIOR - o COAT Q NOR 300M c7 BAFFLE WITH OR EQUAL :J 4"X18' MIN - MAY NOT BE SECTION VIEW NOTE: INLET INVERT IS 3" ABOVE (2" MIN.) BAFFLE MAY NOT BE aenuiR G.. PLAN VIEW OUTLET s - WATER TIGHT JOINT (TYP.) PARSE W/NON-SHRINK GRO T INSIDE & OUT SANITARY TEE ..0, 6"' TO 12" LAYER PEA GRAVEL OR CRUSHED STONE BEDDING LAYER 24" I.D. TAPERED PLUG (TYP.) THE SLOPE OF THE OUTLET PIPE BETWEEN THE SEPTIC TANK AND THE DISTRIBUTION BOX TO BE Ya"" PER FT. 0] OUTLET NOTE: BAFFLE NOT REQUIRED FOR TANKS LESS THAN 10 FT. LENGTH TANK SIZE MIN. LIQUID DEPTH 'A" 1000 GAL. ' � O" TANK DIMENSIONS "B"X"C" "O" "1" HEIS HT 4'-3" x 8'-2" 5'-61' 5'-91" SEPTIC TANK (HEAVY DUTY SEPTIC TANK) _ NOT To scALE FORT MILLER_OR_EQUAL__ -- GRAPE NOTE: 1. PIPE JOINTS TO BE SEALED WITH ASPHALTIC MATERIALS OR EQUIVALENT. 12' MIN REMOVABLE COVER —7 2 INVERT ELEVATIONS OF ALL OUTLET PIPES MUST BE EQUAL. J. THE SLOPE OF OUTLET PIPES BETWEEN THE DISTRIBUTION BOX AND THE DISTRIBUTOR LATERALS SHOULD BE I/8" PER FOOT. BAFFLE o INVERT INLET 2"MIN EL EV. O O O I OUTLET CONTRACTOR TO USE SPEED LEVELERS V AS SUPPLIcD BY FORT MILLER TO EQUALIZE FLOW. 2" MINI CLEAN SAND OR PEA GRAVEL i #2 DISTRIBUTION BOX NOT TO SCALE SHEET 2 OF 2 SANI TAR Y DETAILS FOR LOT 5 & 6 WINDSONG DRIVE HOMESTEAD VILLAGE EENSBURY REN COUNTY NEW YORK TO WN OF QU WAR , SCALE: 9 = 20 OCTOBER 3, 2093 =' ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES F. MITCHELL P.E. 53,337