Loading...
2013-540 TOWN OF QUEENSBURY wow742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20130540 Date Issued: Thursday, January 14, 2016 This is to certify that work requested to be done as shown by Permit Number P20130540 has been completed. Tax Map Number: 523400-289-017-0001-057-000-0000 Location: 31 MARLEY Way Owner: DAVID A DESANTO Applicant: DAVID A DESANTO This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the (e*". a.0 4 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building& Code Enforcement Planning Board or Zoning Board of Appeals. 0.4 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130540 Application Number: A20130540 Tax Map No: 523400-289-017-0001-057-000-0000 Permission is hereby granted to: CURTIS DYBAS For property located at: 31 MARLEY Way in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DAVID A DESANTO Septic Alteration Residential MICHELLE DESANTO Total Value 66 CEMETERY HILL Rd WASHINGTON NJ 07882-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2013-540 Res. Septic Alteration $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,November 25,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ue sbury; o s :y ovember 25, 2013 SIGNED BY for the Town of Queensbury. Director of Building&Co.e Enforcement umce use unit' Town of Queensbury Building & Codes Received: SEPTIC DISPOSAL PERMIT Tax Map ID: g9.11- `,5 Permit No.: ` 3 A permit must be obtained before beginning construction U'N' It'Q o �Permi��e: $ Approvals: Applicant: el, 1 . i fs Installer/Builder lb I4 Oe-TE IL.lEO Address: dOterz.. 121.51 / Address LJ t�C .12Q1' �. 'r 1284b Phone: 5115"1-45 66611 Phone Owner: •. I 0- ._ • Location of Installation SI KNIZL el# l•A`r Address: ,to GEHf liter 14IL1. IZO. e/14µ0.161 LJ, &J J o7 z Phone 1Q$ 4.Pj2. 41rj(Q2. Contact Person for Building&Code Compliance: 15126r SV.U/tLJC141r ELJ60eal2HJ6 Day Phone: 4i4 46,5‘ Residence Information: Year Built #of Bedrooms x Gallons per bedroom =Total Daily Flow 1980 or older x 150 = Garbage Grinder installed? 00 1981-1991 x 130 = Spa or Hot Tub Installed? PO 1992-Present 3 x 110 = 330 Parcel Information: Topography X Flat Rolling _Steep Slope %Slope Soil Nature X Sand Loam Clay _Other Groundwater At what depth? 1.00e. Bedrockllmpervious Material At what depth? �r 1 Domestic Water Supply Municipal X Well(if well,water supply from any septic system absorption is 11 ft.) Percolation Test Rate- 3.6 per minute per inch(Test to be completed by a licensed professional engineer or architect) Proposed System for New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Tank size �2)l) gallon(minimum size 1,000 gallons),add 250 gallons to size of septic tank for each garbage grinder,spa or whirlpool tub System Type: Absorption Field(with#2 stone) Total length 12.00 ft. Each trench_ 70 X 4 Seepage Pit(S)(with#3 stone) How many? Size? Alternative System Bed or other type? Holding Tank System Total required capacity? Tank size? #of tanks? NOTE: 1)Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency-see Certified Electrical form on Town website; 2) Effective as of March 23, 2006 Septic System-As Built Plot Plan: The Building Department will no longer allow systems to be covered until such time as an As-Built Plot Plan is received and approved by the Building Inspector. The installed system must match the septic system layout on file. There will be no exceptions. For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. ✓1 have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Print Name: CU1'LT1� 0. Q1' c3 Date: II/1(/W1172 Signature: ��e J.( Jj Date: I1/ache,I5 Town of Queensbury Building&Codes Septic Dispos ermit 518-761-8256 Town of Queensbury Building & Code Enforcement sus Office No. (518) 761-8256 Septic Inspection Report Inspection request received: Name: 17Inspected on: \ Location: 31 ,v\C.v1 1 Arrive: ) _ . . Permit No.: �0 1 jJ—. Z1� Inspector's Initials: Mgr Com"'nts and/or dia.ram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Vr� C' A Well Casing Length 50'+I- _Y N_N/A l (ELS �\[150'to well required if NO] o� q J1 • Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field 1 Pit Opening Sealed: _Y N End Cap _Y_N Inlet/Outlet Pipes&Baffles _Y N Manholes 12'or less below grade _Y N [provide extension collar if Yes] _Y_N Location/Separations Foundation to tank Foundation to absorption /NY . Separation of Pits . Conforms as per Plot Plan Engineer Report and As-Built ETU Maintenance Contract provided Y N Location of S stem on'Pro•e : Front 'ear Left Side Right Side Middle Front Middle Rear S stem Use Sta s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Septic Inspection Report 0--1 / hi / ..,-.--- _.::., Septic Inspection Report � _ r tr ; 4 Office No. (518) 761-8256 Date Inspection request received: 1 .)--/-',----) I,,errJ l `-7,-- Queensbury Building &Code Enforcement Arrive: am/pm Depart: : al f am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials:( I i (. / l'. NAME: ,ic:.;./1A..1kr PERMIT NO.: V'S l, LOCATION ?\, i\-41 i ,/,0a G.,,,}4-c.,, INSPECT ON: i / O I RECHECK: I / I k_ Comments and/or diagram Soil Type: Sand/ Loam / Clay Type of Water: Municipal / Well Water r ' (`r' -L_;_:- -) 'c sC�`� Waterline separation distance ft. t/ Well separation distance ft. / . I c Other wells: ft. Well Casing Length 50' + / - Y N N/A [150'to well required if NO] l^ Absorption Held: Total length ft. V���ti-d- [L5 i) `1`-1C- ‘ Length of each trench )`, ft. vrA''1\) 4'2,� �' '' \-'01..— Depth of trenches r • ft. Size of Stone' ' �/v`:.(�.i.� +�- '�c-11- =�f!`� L= fr Seepage Pits: Number 1 / --��' `52 N kAi- 1 Size: x Stone Size: Piping ize Type Building to tank _ Tank to Distribution Box ' ` rcu�'i"1_' M;.ti N ?(', \-‘,\ ,).�" —r__ A.----5 Distribution Box to Field / Pit - _ -1� � � ��� —Opening Sealed: Y N k 3 1,L•. " End Cap N Inlet/Outlet Pipes & Baffles44 jig 1 - l '„ ,-, Manholes 12"or less below grade _Y N [provide extension collar if Yes] _ Y NI1 Location/ Separations Foundation to tank /?_:A- ft. • c7 �t\,46-;` -' \-K-A Foundation to absorption y ft. Separation of Pits ft. Conforms as per Plot Plan _Y '1 . Engineer Report and As-Built YC, N ETU Maintenance Contract Y provided Location of System on Property: front Rear Left Side Right Side Middle Front Middle Rear S stem Use S':tus: Approved - ;. V i, Partial Approved anw--.s to be re-ins.- ed 13 -ase call the Building &Codes Office Disapproved �........- L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report03 29 10.doc Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Dgpa(t: ;}i -,�am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: ; \\j/V\ /7 Lti; NAME: S+�,cJ PERMIT NO.: vq- "A" LOCATION: �` NAAO.jam::i _ INSPECT ON: r7— RECHECK: r— 0. Comments and/or diagram Soil Type: 'd/ / Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] r n-r270,1., ) -- Absorption Field: Total length ..'(- ft. Length of each trench t ft. Depth of trenches IN Size of Stone Kf-Z- Seepage Pits: Number L r I Size: V (x Stone Size: Piping Size Type Building to tank �U Tank to Distribution Box --?I‘i Distribution Box to Field / Pit �;�\ l I /r�' —Y r Opening Sealed: �� fY ' N ) [ � ,c ' '--1 `7,�r"�--r_4 i> I ��" End Cap A frV Inlet/Outlet Pipes & Baffles _Y t N Manholes 12"or less below grade _Y N [provide extension collar if Yes] Y N Location/ Separations „- Foundation to tank Foundation to absorption ft. Separation of Pits , „ _ ,ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N ETU Maintenance Contract Y_ N provided Location of_System on Property: • Fro) Rear Left Side Right Sid6 Middle Front Middle Rear System Use Status: Approved V Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report_03 29 10.doc '' !'> r A,,:..FS e .. Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 . • Arrive: am/.v -.art: t` m/pm Date Inspection request received: &!3J�1G(`� Inspector's Initials: ��, • J �- NAME: 1S-e..<f"r\, PERMIT#: ,� G'J'- VC.'% LOCATION: ,--5/ ,Lic:"1 , 1:_j c DATE: fir_; Com, y�3�'r TYPE OF STRUCTURE: '1 ;; r;1 6,;1 kr„ Xi-t ;/— Comments: Yes No NIA 4" Building Number Address visible from road i Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches 0(11/---C- J61-121 Roof Complete/Exterior Finish Complete Platform at all exterior doors �' C/3 ,27 c 2, Handrail 4 or more risers t/ l Guards at stairs, decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more ..,,ik Handrail Termination at Newell Post or Wall , Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet t 6 inch clearance to sill plate – /,_\---D Gas Valve shut-off exposed/regulator 18 inches above grade ..- Interior - Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight /110 Safety glazing/Win w in stairwells safety glazing Interior Smoke De ctors/C rbon Morfoxide etector Every level: Ev r9Bedro : Outside every bedroom rear ��--� Inter Connected: Battery backup: . Attic access 30 inches x 22 inches x 30 inches(height)in accessible area . Ct 4,/• Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft. ventsPlumbs g Fans, if no windows- � Plumbin fixtures c }7 Foundation insulation to floor/Sticker on Panel }� Q Duct work sealed properly/Blower Door Test Certification V --�l� V ` 1/'_ Floor truss,draft stopping finished basement 1,000 sq.ft. , Emergency egress below grade Al. C� l Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area of Furnace/Hot Water Heater operating Low water shut-off boiler e Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%Z"Gypsum Basement stairs closed rise>4 inches / Garage Floor Pitched • r/ Garage fireproofing/%hour fire door/door closer m/ Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker /t Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0 [Temporary/Permanent] 11 /c c 4,5.S 1ii . S‘c3c\ac,c°5 ..,/c)15 6 r A etoer L:\Building & Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7, 2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 SOIL TEST DATA NOVEMBER 11, 2013 0" - 6": TOPSOIL, LEAF LITTER 6" - 13": DARK BROWN SAND, TRACE SILT 13" - 34": REDDISH BROWN SAND, SOME SILT, SOME GRAVEL 34" - 62": LIGHT BROWN TO TAN SAND, TRACE SILT, SOME GRAVEL, COBBLES NO SEASONAL HIGH GROUND WATER TABLE PT -i: PERCOLATION RATE AT 16" EQUALS I'V 3.5 MINUTES PT -2: PERCOLATION RATE AT 18" EQUALS I'V 3.5 MINUTES CAN UTILIZE STANDARD TRENCH SYSTEM PROPERTY LINE (TYP) NEIGHBOR'S WELL 50 FT. MIN. TO SEPTIC TANK 100 FT. MIN TO ABSORTPTION FIELD ,10' 10' MIN. 20' MIN I WELL 100' MIN. FROM NEAREST 4BSORPTION FIELD RESIDENCE j I; I. 4" PVC SDR 35 HOUSE SEWER @ 1/4"/FT MIN SEPTIC TANK 1 4" PVC SDR 35 EFFLUENT SEWER @ 1/8"/FT MIN EFFLUENT PUMP CHAMBER 2" PVC SCH 40 OR SIMILAR (100 PSI RATED) FORCE MAIN DISTRIBUTION BOX on 10' ABSORPTION FIELD j -PLAN - PRECAST CONCRETE ABSORPTION FIELD DESIGN DATA MIN Box AND COVER PUMP FLOAT COMPUTATION ASSUME 4 BEDROOMS (BR) AND A DESIGN PERCOLATION RATE OF IV 5 MINUTES IyY 4' t 4".PIPE VOLUME - 200'. ± X 0.65 GAL/FT TYPICAL LOT DETAI L j PIPE VOLUME = 130 GAL ASSUME 1.6 GALLON/FLUSH TOILETS AND 2" PIPE VOLUME - 67' ± X 0.16 GAL/FT 2.5 GALLON/MINUTE FAUCETS/SHOWERHEADS (N.T.S) PIPE VOLUME - 11 GAL 13" II I/2" - 7.. DESIGN FLOW = 4 BR X 110 GPD/BR REQUIRED DOSE 130 GAL X 0.75 + II GAL 2" DESIGN FLOW = 440 GPD - --- 20' REQUIRED DOSE - 109 GAL '" ' " """` "1e=. _• ` :" a•'. ABSORPTION RATE = 1.2 GPD/SF- - EXISTING GRADE, DOSE PROVIDED = 8.2' X 4.5' X Iz = 3.1 CF/IN ABSORPTION AREA = 440 GPD/ 1.2 GPD/SF I TOPSOIL, FERTILIZE 12" OF SAND, PEA GRAVEL, ABSORPTION AREA - 367 SF � 6' TYP. I AND SEED DOSE PROVIDED = 3.1 CF/IN�,X 7.5 GAL/CF -SECTION - OR 3/4" TO I -I/2" AGGREGATE DOSE PROVIDED = 23.25 GAL/IN STANDARD ABSORPTION DOSE PROVIDED = 23.25 GAL/IN X 5 IN USE ABSORPTION TRENCH DESIGN TRENCH LENGTH - 367 SF/2SF/LF TRENCH SEE DETAIL - ` DOSE PROVIDED = 116± GAL OR 82% DISTRIBUTION BOX TRENCH LENGTH = 184 LF : i\\ " '\' I (N. T. S. ) USE 4 TRENCHES @ 50' i �` ` s �' %/, i�\ x . =i \\ /i ; _ r �f; "T" WITH VALVE AND DRAIN NOTE THIS WASTEWATER TREATMENT SYSTEM IS DESIGNED AND ".�.: 18"-30" '+`" 420.0 ' APPROVED BASED ON THE INSTALLATION OF WATER 417.75' 418.5' 419.25' -USE SPEED LEVELING DEVICES IN EACH OUTLET. IIOGPD PER 2' 0 EXTENSION TO GRADE - USE WATER TO VERIFY EQUAL DISTRIBUTION THROUGH CONSERVING FIXTURES AND A DESIGN FLOW OF BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMODATE I ALL OUTLETS. „ TYFE SPA 24 MIN. EXTREME WATER USE FIXTURES, SUCH AS JACUZZI , T '. P- TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION LOST PROOF JUNCTION BOX EXPLOSION R , OF NON -CONSERVING WATER FIXTURES IS CONTRARY TO THE INSTALL CONTROL PANEL IN HOME Y, DRILL I/4"0 WE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM EP HOLE TO DRAIN FORCE MAIN EVERY CYCLE LOCATION MARKER PROVIDE ACCESS TO GRADE AND SEASONAL HIGH GROUND WATER 2" FORCE MAIN INLET ,, OVERFILL FOR SETTLEMENT, , =7 INSPECTION OF �, *> �1,t� Y. RECAST CONCRETE COVER FOR T x -1 ,w� �; uM. VE FINISHED GRAD FILTER - — Ak . t�f r x„ SEPTIC ",TANK q _� ' `"UNION 12`+ - - ,- -., ,3,. CHECK VALVE ��1 � PERFORATED 4" PVC PER . >_ ` 6„ TO 12" FILTER FA ION PUMP EFFLUENT FILTER FIELD "SECT :, PUM i; PUMP ON ' ABSORPTION -- - 5' PUMP OFF SOIL BACKFILL �:.. 2" 7" SANITARY TEE BLOCK PUMP I AS REQUIRED Mw 1 6" IMUM 6 GRAVEL 4„ U 30„ I' CAULKED JOINT (TYPICAL) IJ h 3/4" TO I I/2" WASHED 6" i (LONGITUDINAL SECTION) GRAVEL OR CRUSHED STONE MIN TO I NOTES 31, MIN 60° -- 6" OF SAND, PEA SEAL ASL OPENINGS WATERTIGHT (CROSS SECTION) 11 2' MIN TOSHGW GRAVEL OR 3/4 To 1-1/2" AGGREGATE WATERTIGHT SEAL ALL COVERS, JOINTS AND PENETRATIONS A RELEASED FOR APPROVAL A A 0 0 NO. 6 MIN WALL THICKNESS FOR POURED IN PLACE INLET OUTLET PRECAST OR POUREE CONCRETE SEPTIC T CONCRETE SEPTIC TANK NTS NOTE: USE 1250 GALLONS FOR 4 BEDROOMS USE 1000 GALLONS FOR 3 BEDROOMS OR LESS NOTE: - INSTALL POLYLOK PL -122 RESIDENTIAL WASTEWATER EFFLUENT FILTER IN OUTLET TEE - GARBAGE GRINDER SHALL BE CONSIDERED EQUIVALENT TO AN ADDITIONAL BEDROOM FOR SIZING SEPTIC TANK. AN OUTLET GAS DEFLECTION BAFFLE AND A TWO COMPARTMENT SEPTIC TANK IS REQUIRED WHEN A GARBAGE GRINDER IS INSTALLED - INSTALL TEE IN TANK INLET AND OUTLET 16" AND 18" BELOW LIQUID LEVEL RESPECTIVELY DESCRIPTION REVISI❑NS 1/19/131 BWW I ZNM I 0 0 JA0 DATE OWN CHE�cKEDNO DOWN SLOPE 20' 6' —I— — _ 6' 24" TYPICAL 50' ABSORPTION TRENCHES ABSORPTION FIELD PLAN VIEW (N.T.S.) USE 4 LATERALS @ 50' FOR 4 BEDROOMS DESCRIPTION REVISI❑NS DATE DWN SET ALARM 6 ABOVE PUMP ON Fret W. Winchip Engineering, P.C. DISTRIBUTION INSTALL POWER AND CONTROL WIRES TO CONTROLLER LOCATED IN HOUSE 2' MIN TO BEDROCK P.O. Box 116, 6272 State Route 9 BOX - USE 1000 GALLON SEPTIC TANK FOR PUMP CHAMBER Chestertown, New York 12817 - PUMP SHALL BE GOULDS WE0312M, 230 VOLT, 1,750 RPM SUBMERSIBLE TYPICAL SECTION TO PUMP 32 GPM @ 20' TDH - INSTALL GOULDS S10015 CONTROL WITH ALARM LIGHT AND FLOAT ABSORPTION TRENCH SWITCHES AS REQUIRED -.,USE NEMA I FOR INSIDE MOUNT i - PROVIDE"T" WITH GATE VALVE TO DRAIN (N. - CONTRACTOR SHALL VERIFY EXISTING ELECTRICAL SERVICE PRIOR ,5.) THE DESGN PRESENTED IN THIS DRAWING IS ONLY NOTE: INLET FROM TO PURCHASING PUMP(S) It is a violation of New York State Education LOW Article NOTES: TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK TAX MAP# 289.17-1-57 THIS DRAWING BY ANY OTHER ENTITY FOR ANY EFFLUENT PUMP - PROVIDE FROST PROTECTIVE SOIL COVER OVER FORCE MAIN - SPACE ABSORPTION TRENCHES 6' MIN O.C. OR AS NOTED OTHER FURPOSE IS A VIOLATION OF APPLICABLE to alter an item in any way. 9f an item bearing the 1z ° * .. -.SLOPE PERFORATED PIPE I/16" TO 1/32" PER FT M p UM DETAIL % -TRENCH BOTTOM LEVEL seal of an engineer is 'altered, the alteringengineer shall affix to the item his seal and the notation m HIS DRAWING' IS THE PROPERTY OF EFFLUENT ,I :p - DO NOT INSTALL IN WET SOIL DAN. BY: BWW DATE: 11/14/13 _• • - RAKE SIDES AND BOTTOM OF TRENCH BEFORE C,` I • ,osaoi� BRET W. WINCHIP ENGINEERING, P.C. CHK'D BY: ZNM DATE: PLACING GRAVEL alteration. s A HP�� 90FESSIl ALL DIMENSIONS AND INFORMATION IS — TRENCH 24" WIDE, 30" MAXIMUM DEPTH TO BE VERIFIED BY THE CONTRACTOR PROJECT NO. 13-130 APPR'D. - CAP LATERAL ENDS Fret W. Winchip Engineering, P.C. P.O. Box 116, 6272 State Route 9 Chestertown, New York 12817 Phone: (518) 494-2555 Fax: (518) 494-2566 4 PROJECT: DESANTO PROPERTY WASTEWATER REPLACEMENT DETAILS THE DESGN PRESENTED IN THIS DRAWING IS ONLY NOTE: f NE! dVy FOR THE CONSTRUCTION WORK SHOWN. USE OF It is a violation of New York State Education LOW Article �� TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK TAX MAP# 289.17-1-57 THIS DRAWING BY ANY OTHER ENTITY FOR ANY undeS ctiothe 7dire209 forany person,unlessis ding, �S�P�jEAW�1 09 OTHER FURPOSE IS A VIOLATION OF APPLICABLE to alter an item in any way. 9f an item bearing the 1z ° * LAWS. seal of an engineer is 'altered, the alteringengineer shall affix to the item his seal and the notation m HIS DRAWING' IS THE PROPERTY OF SCALE: AS NOTED DAN. BY: BWW DATE: 11/14/13 _• • "altered by" followed by his signiture and the date of such alteration,' and a, specific description of the C,` I • ,osaoi� BRET W. WINCHIP ENGINEERING, P.C. CHK'D BY: ZNM DATE: 11/19/13 alteration. s A HP�� 90FESSIl ALL DIMENSIONS AND INFORMATION IS — TO BE VERIFIED BY THE CONTRACTOR PROJECT NO. 13-130 APPR'D. BI Ij BEFORE CONSTRUCTION. �IOV_21 2013 SHEET NO. 2 OF 2 REV. 0 ,a a,