Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2014-129
` ` TOWN OF QUEENSBURY E^> o 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140129 Date Issued: Monday, April 27, 2015 This is to certify that work requested to be done as shown by Permit Number P20140129 has been completed. Location: 7 MOCKINGBIRD Ln Tax Map Number: 523400-315-006-0002-037-000-0000 Owner: JAMES & TANYA JOHNSON Applicant: JAMES & TANYA JOHNSON This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property �d n /� 41-it owner of the responsibility for compliance with Site Plan, Variance, or / other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140129 Application Number: A20140129 Tax Map No: 523400-315-006-0002-037-000-0000 Permission is hereby granted to: JAMES R JOHNSON For property located at: 7 MOCKINGBIRD Ln in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JAMES R JOHNSON Deck $2,500.00 9 AMERICAN Way Total Value QUEENSBURY NY 12804-0000 $2,500.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans &Specifications 2014-129 DECK 320 sq ft $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, April 23,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town Quee bury re i i •s,/: t ri123,2014 I\ ,Vi SIGNED BY w for the Town of Queensbury. Director of Building& Code Enforcement O. Town of Queensbury Build 0 ces _ofrP use Only It GEGY ACCESSORY STRUCTUR LICATION • ived: M�p 31.x, 1P - a- s ID: / A permit must be obtained before e i mg cAiTicuctl 2014 gr. ILI- 1,21 dN�No.. For any structure other than residential principal strua h eyt�o-�udelSbuuta.i Permitt Fee: tib -0 a not limited to: garage, shed, dock deck, carport, pole, arp,�-green& g1.1RYSite Plan No.: Refer to Informational Brochure No.3 Accessory Structtes=-Sheds�Fences-t="2.-____,J Date i//)//PON Applicant 7 iefibb4rCOvnfl / 3/44W5 tMM,3Pii TaxMaplD 31,c (49 -.7- 37 Address 7Mau4woL31eel) in-0,1 Zoning S 0✓F� r?uL'i /,2Sotf Phone ($(b) -7W- '//O Owner "Thienca /r "',Muhl,✓ ContractorlAgent fit 574ona Address 7!,fock/NL e//?D tA^C� Address qt Mrn&etikw AV la�✓aM 8 '-Y AN aWY 6LFia Fi4u.3 NY /,tia4 Phone (QV) - 2W--6/d C, 'Phone� f�/4�) 3o7 '/�/rf Contact Person for Building&Code Compliance: 3,c S� P (eCZ)v-- Day Phone: 307-fit ci Building Street Address: 7 Roar/fit 6 um meor QJ Cfrobore Mf Oky Subdivision Name: Lot#: Historic Site: Yes iL No Estimated cost of construction: E O C) ' 0 0 Are there any other accessory structures on property? If yes,please list MO Type of Construction: Check all that apply Please indicate measurements as required below 1#Floor sq.ft. 2nd Floor sq.ft. Total sq.ft. Height Boathouse Boathouse with Sundeck Deck flQ 3 Q Detached Garage(#of cars_) Dock Pole Barn Porch-Open **Porch-3 season,Covered, Enclosed Shed Other Accessory Structure(s) **Considered floor area&must comply with FAR(Floor area ratio)requirements if located in the Waterfront Residential zone. Town of Queensbury Building&Codes ArrPssory Structure Packet 518-761-8256 11 Please include two(2)sets of the following documentation with the application fee: 1. Accessory Structure Application 2. Plot plan drawn to scale with the use of a survey map, if possible[40 scale-1 inch=40 feet] a) Indicate proposed structure,showing setback dimensions from all surveyed property lines b) Show location of all existing structures on the property c) Show location of water supply(well or water lines) d) Show location and configuration of septic disposal system or sewer line 3. Structural Drawings to include: Floor Plan; Foundation Plan; Cross Sections; Elevations 4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations with construction costs over$20,000;Any commercial construction Other Notes: 1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are necessary]. 2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial application date. 3. Additional Review-All Applications are subject to Zoning Administrator,Code Compliance,and Structural plan review CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL) Residential Building Code • New driveway requirements for structures located over 300 feet from main road; • Spray foams are allowed to be exposed in rim joist box area only,must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements; • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps; • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles; • GFI protection for all other receptacles in kitchens, bathrooms,garages,and unfinished basements; • All receptacles must be tamper resistant; • Carbon Monoxide detectors must be located within 15 feet of sleeping area; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Enerqv Code Requirements • Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant; • Programmable thermostats required; • Lighting must be 50%energy saving light bulbs; • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit; • Res Check inspector's checklist must be available at time of insulation inspection Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above Print Name: V)14-142/J OI Signature: Date: 414111 11 Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Queensbury Building & Code Enforcement - Residential FinalFiInspection Office No. (518) 761-8256 �t l Arrive: 2_� a gale s- .- : 7:n am Date Inspection r uest received: 91')-it 15 Inspector's Initials: NAME: JOInns-cvnP R IT#: 1.1- (2-9 LOCATION: 1- MO C)onb1 rd D/kTE: .4%121 12W 5 TYPE OF STRUCTURE: Qac_ 1 Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height!"B"Vent/Direct Vent Location J Urn — I\ 19 Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 Inches or more ,Gua tdeck. porches'6Jnches or more (ilii Termination at Newell Post or Wall / Intenor/Exterior Railings 34inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: _ Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched I U Garage fireproofing/%,hour fire door!door closer ��� C� Gas Logs in Sealed or Glass Enclosure r Final Electrical;Energy Saving Light Bulbs 50% �t J V v Final Survey Plot Plan /� Arc Fault Breaker Habitable Spaces!Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required ' / Okay to issue C I C or C/O[Temporary/Permanent] Y I rkss hbs �f e 0.0l5 er nowe,r L:1Buiiding &Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008; Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 ^i)) w mo Queensbury Building & Code Enforcement - Ryesidential Fi al Inspen���i Office No. (518) 761-8256 Arrive: �-yi3o 95r Date Inspection request received: Inspector's Initials: NAME 5fksvnSof\ P-. T#: ly-/ Q9 LOCATION: 7 MvOKi, jrd 0 ck- z�-t TYPE OF STRUCTURE: 13e Mt 7- l u.Th Pf=d 1 O_ I- '7 Co ments: Yes No N/A-0- t 4° Building Number Address visible from road Chimney Heigh!°B'Vent/Direct Vent Location i2-A tJT_ 1A catass Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete / / - AD 0 HOT O t pyF Q Platform at all exterior doors et LJ A NO ZS-O 1 CD 0 Handrail 4 or more risers Guards at stairs,decks, patios more than 30 inches above grade R 1 L5 (o Guard at stairwell at 34 inches or more / '- '1)au� AL Guard at deck,porches 36 inches or more / ,/ GOC) O��J Handrail Termination at Newell Post or Wall ✓ LI-\ Z M Interior/Exterior Railings 34 inches to 38 inches — ASO 55 t So Deck Bracing I Handicapped Ramp Compliant O EC-l4 n n Q o? 2,E\ Grade away from foundation 6 inches with 10 feet ]-Rl 13 ec\L O Po131-b• 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade — \OE� R ER `' Interior privacy/trim/doors/main entrance 36 inches Q Bathroom/Kitchen watertight F e' J- Safety glazing/Window in stairwells safety glazing v� �U c'Q ORT t0 7 lSF Interior Smoke Detectors!Carbon Monoxide Detectors POhT IN--Tim 9x n.J�`` Every level: _ Every Bedroom: _ llfty7 Outside every bedroom area: _ -- ADV \-\CV- ro\ Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area 6ALJ Aw\\"LE9 tJA\fie) Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents NO\)bE L.ED6F 1�4 TCt. Bathroom Fans,if no window Plumbing fixtures la PIA __ \D b TO Foundation insulation to floor/Sticker on Panel Op- Q (j ECsm . Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area ..°` Fumace/Hot Water Heater operating F1�pry�►�o`� Low water shut-off boiler �y` A J� Relief Valve(s)installed/Heat Trap!Water Temp 110 ,. �� Enclosed Stairs Sheetrock Underside minimum'W Gypsum \ R T VERt P ?s Basement stairs dosed rise>4 inches b t3 L %kt L w-I. t.3 E Garage Floor Pitched B E k M\ -c-z3 fireproofing/'''A hour fire door/door closer Co(2-0-6.. wit 1�\S M DF t t Gas Logs in Sealed or Glass Enclosure — t 1Js" A`' the-0'>bF_P '" F' Final Electrical;Energy Saving Light Bulbs 50% Rt'\ RvWRF F1Rw>DRa\\ _ TpY T Final Survey Plot Plan g©1 iDM D nh1 Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles p Flex Gas Pipe Bonding A� bW31Q" •; As Built Septic System/Sewer Dept. Inspection Sticker — Lif\t_L Site Plan /Variance required / RSC HE , Flood Plain Certification,if required / la F1, DF- (A0► A\ Okay to issue C/C or C/O[Temporary/Permanent] vvV L:\Building&Codes FormsSBuilding&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008; Revised 6/26/08;Revised 12/22/10, Revised 04/13/11 Foundation Inspection Report , Office No. (518)761-8256 Date To, - ;on -r ? Queensbury Building&Code Enforcement Arrive: \ , 1110 :.i j 7-part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto s •'ti: i „ . NAME: eOES OhnSpol PE'` IT#: LOCATION: r7 MvC.f'(t ro b a INS'ECT ON: 'y- TYPE OF STRUCTURE: J J@GK Comments Y N N/A f outings kt” PL's h tie43a v"�t� l 1 Monolithic Slab ®, Reinforcement in Place The contractor is responsible for ‘22 providing protection from freezing 3 pt. \W€ for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. t:\Bullding&Codes Forms Building&Codes\Inspection Fonns\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM C _ IkiP Lag .4„.:, EDARc 1%i,. r: ! Jii..4N OF OUEENSBUr.. 'J ,, ,s •y �r . ECE1VED 298 � x m o— a a ' Irk?Or. m Cfi 2 2 1992 ..-'-- oea E Vj [s 1I1n111 'f. ,, .4-e�b��sJ _ 1 WI Ey 1 1 _feta_tt9,.0E� , I I • APR 21 2014 U �"! PIC-_,., _ I — SBURY TOWt10 QUAE DES ITH fi afa.J :, MOCKINGBIRD LANE 0 I t s75' 05' 00' EveZ ��" b0.1.41112 411 M10Pj -_ �L. - Ater' }-- �-+� Ju 1p1osJ own t_-.1;,f ._. 4' 'I 100.00 — _ ;* IHAJEPERSONALL r. aurst- cJIS? `� E _ iso+ nom + - •TOM THE PRO EF�Y LINES Ti t • T —` \•-10SED STRUCTUF2F(S)OR S) j ;k' \r \\ 0n 1 WD.uc — -r id c---+-- I t sic I 7 ' . •iiiii - ¢SW3 0 �x�tu 1 • . MODEL 38 FU1t2Z 1 0 x I GpQGC E FF. El .r 307.17 1 .6 u• a 2G'•o. _ - • 4a•o ,.. 24--o j lo-o. If I i in Al sl I �cIL I N. I pREGor, ��- ., ® ?°ILrJ re M . � � I Nels APPROVED -. I I Appal• tion I / / a 1 — — / OCT 2 6 " 10 0 1 �IELO. / N ,i �Lr� cw ` G t.0 • 11-o L 1{7(1.00" / I 10.21.92 CUSHING, DYBAS ASSOCIATES, ARCHITECTS. P.C. PLOT PLAN LOT 32 1 INSPIRATION PARK icl'AlG 1"r-.20' am ry.;.. ••..A � • -.ne r*' 1 R VISIT DECKS.COM FOR MORE FREE DECK PLANSTO �. .,. ,M. �, �. .. OUEENSBURY I 1 7 I IW mg- 'E Jr r-f c ...' Buu ILDINGDEPARTMENT F BUILDING & CODES "' PT. Based or,our limited examination,cnante e rrin with our commenta shall not be co, •,L;, a;• i R"`°e' 'ded y o indicating the plans and sppecifll,,.;;.,r. II 1 I � � n� full compliance with the Building Cwt. Date: 75\=C= > z New YDIF.Stare. I a D.VI Uj .D' SCALE: 1/4" = 1' WHEN PRINTED ON 11x17 PAPER BASED ON THE INTERNATIONAL RESIDENTIAL CODE STAIRWAY ILLUMINATION:ALL EXTERIOR STAIRWAYS ID �� {�\� � ('�(^/ SHALL OE ILLUMINATED AT THE TOP LANDING TO LO .�Rl.Jk.. S�„ —5 THE INSIDE ILLUMINATIONDWELLISHALL BE CONTROLLED \\VVJ— \ L FROM INSIDE THE DWELLING OR AUTOMATICALLYACTIV0 DISCLAIMER:THIS PLAN IS NOT CONSIDERED COMPLETE UNLESS ANSI APPROVED BY YOUR LOLL BUILDING NDINSPECTOR OR STRUCTURAL ENGINEER. t, 3s LIt c,C tO 3 IJ (y[ l LU z BUILDER ACCEPTS ALL RESPONSIBILITY AHD LIABILITY. /�`NNN"'���� ��`/�—d !(V O-IJ DECKS CON LLC,AND ASSOCIATED SPONSORS p// N ACCEPT NO LIAOILIIY FOR MC USE or THIS PLAN. 1 - \- Z Y W LEDGER BOARD d _ d a O z HOUSE Bae ledger board detail) 6 20' 1 I n1 5 11111 o I. �� INSTALL BRIDGING .. E �"� 4. AT MID SPAN I—I e ` s DO:x N <:'------:f • AI 6 16B. $ HAND RAIL • In d - 6 g G . _ d _ 9 3 e�pl r 3 0 E t a d ` b3 . _ 55 ; 9 •i3, I 12' 'oA n. g 6w 6 so m m a 0 1B' E � h � g I y. 33, P; W a : o DROP BEAM a 1.2®.1 ID'DIAMETER FOOTINO FOOTINGS To BE INSTNLZD (1/U'1 i0 PROPER DEPTH AE IS 1� REQUIRED BY YOUR LOCAL O ,. BUILDING ORDNANCE ® 18'DIAMETER FOOTING FROST FDOIINOS SIZES BASED ON OS LB PER SQUARE FOOT DISCLAIMER: ONLY USE#2 OR BETTER PRESSURE TREATED TRIBUTARY LOADS APPLIED TO 1500 PSI SOIL COMPRESSION CAPACITY(ASSUMED RWSEOS E) SOUTHERN YELLOW PINE 2 H 10 FOR FRAMING MATERIALS r. X I II' DIAMETER FOOTING NEVER SUBSTITUTE COMPOSITE OR SOFTWOODS FOR FRAMING MATERIALS SEE FOOTING DETAIL IN DECK CONSTRUCTION GUIDE. DISCLAIMER THIS PLAN IS NOT CONSIDERED COMPLETE UNLESS APPROVED BY YOUR LOCAL BUILDING INSPECTOR OR STRUCTURAL ENGINEER.BUILDER ACCEPTS ALL RESPONSIBILITY MID LIABILITY DECKS.CON LLC.AND ASSOCIATED SPONSORS ACCEPT ND LABILITY FOR THE USE Of THIS PLAN. 0DECKS COM LLC . SCALE: 1/4" = 1' WHEN PRINTED ON 11x17 PAPER BASED ON THE INTERNATIONAL RESIDENTIAL CODE,amas--1 law p �J I- b P — , s v° �VA- `1,,,0•1/2),(041Z._ t `1z._ I >'\l OR 0 -2O' 2 � l �vo ? az Y w 41. L 0 p w EC HOUSE o o' `t MB 'a Au1 mh'o �R�B R ( C r © no.49gt 8 GZ R Y 1,. 1 cz z F e • US E a O O � : 2 10 Q . -,4,,, ^7aM LO R r kie nn�S �V 1E13 ISA TRIANGULATION REFERENCE POINT MEASURE TO THE CENTER OF YOUR FOOTINGS THESE POINTS. �A DISCLAIMER, USE ONLY 3.500 PSI CONCRETE 40/ FOR FROST FOOTING FOUNDATIONS -( DISCLAIMER. THIS PLAN IS NOT CONSIDERED COMPLETE UNLESS APPROVED BY YOUR LOCAL BUILDING INSPECTOR OR STRUCTURAL ENGINEER.BUILDER ACCEPTS ALL RESPONSIBIUTY AND LIABILITY. DECNS.COM LLC.AND ASSOCIATED SPONSORS ACCEPT NO LIABILITY FOR THE USE OF THIS PLAN, 0ECKS COM LLC