Loading...
2014-190 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20140190 Date Issued: Friday, March 18, 2016 This is to certify that work requested to be done as shown by Permit Number P20140190 has been completed. Tax Map Number: 523400-296-008-0001-009-002-0000 Location: 75 WAVERLY P1 Owner: JEANE SAVIETTA Applicant: JEANE SAVIETTA This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building& Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140190 Application Number: A20140190 Tax Map No: 523400-296-008-0001-009-002-0000 Permission is hereby granted to: JEANE SAVIETTA For property located at: 75 WAVERLY P1 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JEANE SAVIETTA Deck $9,000.00 75 WAVERLY P1 Total Value QUEENSBURY NY 12804-0000 $9,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency JOSEPH VITALE 518-466-4011 481 MILLER Rd CLIFTON PARK NY 12065-0000 Plans&Specifications 2014-190 DECK 200 sq ft $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,June 06,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town f Que ship;4 F i : i 1 e 16,2014 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Town of Queensbury Building & Codes Office Use Only ACCESSORY STRUCTURE APPLICATION `Received:; r: �, Tax Mapja _ .� ' - ',01 A permit must be obtained before beginning construction �� 2 Kermit No.: \•� `�, App For any structure other than residential principal structure(house)to include, but . 1�Prmit Fed' - not limited to: garage, shed, dock deck, carport, pole barn, greenhouse, etc. bite p a�_ ut: Q P G Q� Refer to Informational Brochure No.3 Accessory Structures—Sheds/Fences 'u\1\i �1��� .--� Date // Applicant ti^y JOsEP} !"l Lr I-r-t(e b si 'acee I Prt-( Tax Map ID Address '__./ / n"/•I/'ie kb nxfeV'cir ZoningCi/ T - Pfpe N ( 12c s Phone / 57E 4/660-1/0 Ownerl ems-- Contractor/Agent Siclo7E H5 Address 75 (,U VE, Ly iafiec Address r4 &OV(- Qoe sbLL r ivyz2Otf . Phone �G 3 `f(2 1 Phone Contact Person for Building&Code Compliance: JO(' U I TF (.C= Day Phone: SI c-^ L Coo'y 01 I Building Street Addrr: Subdivision Name .t. vUe((t Pace o #: Historic Site: Yes _No Estimated cost of construction: $ 7C) Are there any other accessory structures on property? If yes,please list: Type of Construction: Check all that apply Please indicate measurements as required below 1st Floor sq.ft. 2nd Floor sq.ft. Total sq.ft. Height Boathouse Boathouse with Sundeck Deck ,Wir, Si 11— Detached Garage(#of cars_) Dock Pole Barn Porch-Open **Porch-3 season, Covered, Enclosed Shed Other Accessory Structure(s) **Considered floor area&must comply with FAR(Floor area ratio) requirements if located in the Waterfront Residential zone. Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Please include two(2)sets of the following documentation with the application fee: 1. Accessory Structure Application 2. Plot plan drawn to scale with the use of a survey map, if possible[40 scale-1 inch=40 feet] a) Indicate proposed structure, showing setback dimensions from all surveyed property lines b) Show location of all existing structures on the property c) :Show location of water supply(well or water lines) d) Show location and configuration of septic disposal system or sewer line 3. Structural Drawings to include: Floor Plan; Foundation Plan; Cross Sections; Elevations 4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations with construction costs over$20,000;Any commercial construction Other Notes: 1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are necessary]. 2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial application date. 3. Additional Review-All Applications are subject to Zoning Administrator, Code Compliance, and Structural plan review CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL) Residential Building Code • New driveway requirements for structures located over 300 feet from main road; • Spray foams are allowed to be exposed in rim joist box area only, must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements; • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps; • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles; • GFI protection for all other receptacles in kitchens, bathrooms, garages, and unfinished basements; • All receptacles must be tamper resistant; • Carbon Monoxide detectors must be located within 15 feet of sleeping area; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Energy Code Requirements • Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant; • Programmable thermostats required; • Lighting must be 50%energy saving light bulbs; • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit; • Res Check inspector's checklist must be available at time of insulation inspection Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. 11 have read and agree to the above Print Name: JOESz✓p-F( U ('ill LE Signature: Date: .57 /Z-//L( Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256 Residential Final Inspection ` 0 e Inspection request received 31.'117c\ Name Inspected on `)) 1*rf Location �l�va�r�r\\.1 Ickcu Arrive am/pm Permit No. 20 l — 1C) Inspector's Initials Type of Structure 1L% ( ( C �4S� t,� Yes No N/A Bathroom Fans, if no window 4" Building Number Address visible from road Plumbing fixtures Chimney Height/"B" Vent/Direct Vent Foundation insulation to floor/ Sticker on Panel Location Fresh Air Intake Duct work sealed properly/Blower Door Test Certification 3" Plumbing Vent through roof minimum 18" Floor truss,draft stopping finished basement Roof Complete / Exterior Finish Complete 1,000 sq.ft. Platform at all exterior doors Emergency egress below grade Handrail 4 or more risers Gas Furnace shut-off within 30 ft.or within line Guards at stairs, decks, patios more than 30 " of site above grade Oil Furnace shut-off at entrance to furnace area Guard at stairwell at 34" or more Furnace/Hot Water Heater operating Guard at deck, porches 36 "or more Low water shut-off boiler Handrail Termination at Newell Post or Wall Relief Valve(s) installed /Heat Trap/Water Interior/Exterior Railings 34 "to 38 " Temp 110 Deck Bracing/ Handicapped Ramp Compliant Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 " with 10 feet Basement stairs closed rise+ 4 inches 6" clearance to sill plate Garage Floor Pitched Gas Valve shut-off exposed /regulator 18"above grade Garage fireproofing / /, hour fire door/door closer Interior privacy/trim /doors/ main entrance Gas Logs in Sealed or Glass Enclosure 36 " Bathroom / Kitchen watertight Final Electrical; Energy Saving Light Bulbs 50% Safety glazing/Window in stairwells safety Final Survey Plot Plan glazing Arc Fault Breaker Habitable Spaces/Tamper Interior Smoke Detectors/ Carbon Monoxide Proof Receptacles Detectors Flex Gas Pipe Bonding Every level: Every Bedroom: As Built Septic System / Sewer Dept. Inspection Outside every bedroom area: Sticker Inter Connected: Site Plan /Variance required Battery backup: Flood Plain Certification, if required Attic access 30" x 22"x 30" (height) in Okay to issue Temporary/ Permanent accessible area Certificate of Occupancy OR Crawl Spaces 18" x 24" access,1 sq. ft.-150 sq. Certificate of Compliance ft. vents Yes No N/A Comments: 44 Town of Queensbury Building & Code Enforcement Office No. (518)761-8256 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart:/ pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: c/' NAME: S PERMIT#: / t-/–% �l) LOCATION: C7 UJ 6,1)u—ed PJ INSPECT ON: TYPE OF STRUCTURE: iJ ce i Comments N ' N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM CONSTRUCTION: ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL BUILDING CODE AND/OR LOCAL REQUIREMENTS. NOTES: - SEE DETAIL SHEET FOR CONNECTIONS - LEDGER BOARD NEEDS TO BE LAGGED TO THE EXISTING STRUCTURES RIM JOIST THAT IS A MINIMUM OF 1-1/2" THICK. - JOISTS SHALL NOT CANTILEVER MORE THAN 1/4 ITS SPAN CONTINUOUS SO BLOCKING EXISTING SUNROOM Z. IT IS A VIOLATION OF LAW FOR MY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A IICEN.ED PROFESSIONAL ENGINEER, ARCHITECT, IPNDSCAPE ARCHITECT OR LAND SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM 8EARING THE STAMP OF A UCENSED PROFESSIONAL IS ALTERED, THE ATTENDS ENGINEER, ARCHITECT, WJOSCAPE ARCHITECT OR LAND SURVEYOR SHAU. STAMP THE DOCUMENT, AND INCLUDE THE NOTATION -ALTERED BY' FOLLOWED BY THEIR SIGNATURE, THE DATE OF ALTERATION, AND SPECIFIC DESCRIPTION OF THE ALTERATION. EXISTING STRUCTURE 2x8 LEDGER N a BEAM (2)2x10 SPAN 6.0' max. CONCRETE FOOTING 6x6 POST (TYP.) 2x8 JOIST 16° O.C. ESI A 6.00 i —20.00 PLAN VIEW 3.00 TANG DECKING -g,00 ALL DIR. (TYP.) i 4' STAIRCASE I TOWN OF QUEENSBURY BUILDING DEPARTMENT Based ith our comments$ examination, a I npot benconstruled as in fulfil compliance) withatheSBuilding Codes of New York State. i"01M OF 04 Reviewed By Date; DESIGN PARAMETERS: FOOTING - 12" DIA. CONCRETE PIERS LUMBER IS PRESSURE TREATED HARDWARE IS GALVANIZED OR EQUAL POST SIZE - 6x6 (ANCHORED) BEAM SIZE - (2) 2x10 JOIST SIZE - 2x8 DECKING - 5/4 x 6 BEAM SPAN - 6.0' MAX JOIST SPAN - 9' MAX JOIST SPACING - 16" O.C. MAY 2 3 2014 TOWNUP1ilEENSBURY BUILDING & CODES NOTES: - SEE DETAIL SHEET FOR CONNECTIONS - LEDGER BOARD NEEDS TO BE LAGGED TO THE EXISTING STRUCTURES RIM JOIST THAT IS A MINIMUM OF 1-1/2" THICK. - ALL WOODEN MEMBERS EXPOSED TO THE WEATHER MUST BE TREATED. - ELEVATED DECKS SHALL BE BRACED WITH 4x4 MEMBERS ORIENTED PARALLEL TO THE BEAMS FROM THE POST TO BEAM AT 45 DEGREE ANGLES CONNECTED WITH BOLTS OR APPROVED EQUAL. TALLER POSTS REQUIRE LONGER AND MORE SUBSTANTIAL BRACING. EXISTING GRADE i *RAILING NOT SHOWN SEE DETAIL SHEET PT DECKING 5/46 1�1 & PT JOIST 2x8 @ 16" o.c. �Xj LEDGER BOARD N (2)2x10 DROP BEAM 6x6 P.T. POST (TYP.) Fli 4 - (MIN) 1.00 IT IS A VIOLATION OF -kW FOR ANY PERSON, UNLESS THEY ME ACTING UNDER THE DIRECTION OF A LICENSED PRUFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR TO ALTER AN ITEM IN ANY WAY. IF AN ITEM BEARING THE STAMP OF A DCENSED PROFESSIONAL IS ALTERED, THE ALTERING ENGINEER, ARCHNFECF, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT, AND INCLUDE I HE NOTATION -ALTERED BY- FOLLOWED BY THEIR SIGNATURE. THE DATE OF ALTERATION. AND SPECIFIC DESCRIPTION OF THE ALTERATION. CONTINUOUS SOLID BLOCKING BEAM BOLTED WITH (2) 1/2" DIA. CARRIAGE BOLTS TO POST (TYP.) q (CONCRETE FOOTING - 12" DIA. a N of 10.00 SECTION A -A EXISTING STRUCTURE GENERAL CONSTRUCTION NOTES: DECK: PT LUMBER CIP CONC. FOOTINGS RAILINGS / STAIRS: PRESSURE TREATED LUMBER GUARDS @ 36" HEIGHT MIN. <4" BTWN & BELOW BALUSTERS / OPENINGS 2x10 STRINGERS (MIN.) MIN. TREAD 9" MAX RISER 8.25" HANDRAIL HEIGHT 34" HARDWARE: ALL HARDWARE IS STAINLESS STEEL OR GAL. SIMPSON STONG TIES OR EQUAL FULL ROUND HEAD NAILS GENERAL LEDGER NOTES: REMOVE SIDING PRIOR TO INSTALLATION CONTINUOUS FLASHING W/ DRIP EDGE - LEDGER BOLTS SHALL BE 3/8" DIA. x 6" LONG INSTALLED IN 1/4" PRE -DRILLED HOLES PLACED 6" MAX. o.c. (STAGGERED PATTERN) - LEDGER SAME DEPTH AS JOIST (OR DEEPER) - THIS DECK CONNECTION DETAIL IS BASED ON THE ASSUMPTION THAT A MIN. 1-1/2" THICK WOOD MEMBER IS ADEQUATELY INSTALLED AT ALL EDGES OF THE 2nd FLOOR DIAPHRAGM. IF ANY OTHER MATERIAL IS USED, SUCH AS TJI JOISTS, AN ENGINEERED DESIGN BY A LICENSED ENGINEER WILL BE REQUIRED. IT IS THE BUILDERS RESPONSIBILITY TO VERIFY THE PRESENCE OF THE APPROPRIATE RIM JOIST OR TO BUILD A FREE STANDING DECK. I t2-1/2!'dia, thru-bolls wl washers TYPICAL POST/ BEAM CONNECTIONS -CARRIGE BOLTS OR RSS pIl TYPICAL LEDGER BOLT PATTERN DECK JOIST JOIST HANGER (SIZED TO JOIST) EXISTING STRUCTURE 1/2" DIA. x 6" LAG SCREWS 6" o.c. or EQUAL I I EXISTING 2x BAND JOIST i TEXISTING ', FOUNDATION i TYPICAL LEDGER DETAIL - NOT TO SCALE LEDGER TO CONCRETE 3'Min Slaecmver TYPICAL POST / FOUNDATION CONN. • SIMPSON STRONG -TIE OR EQUAL IT IS A VIOLATION OF LAW FOR MY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR TO ALTER AN ITEM IN MY WAY. IF AN ITEM BEARING THE STAMP OFA LICENSED PROFESSIONALIS ALTERED, THE ALTERING ENGINEER. ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT. ANU INCLUDE THE NOTATION 'ALTERED BY -FOLLOWED BY THEIR SIGNATURE, THE DATE OF ALTERATION, AND SPECIFIC DESCRIPTION OF THE ALTERATION. 4" OPENING MAX. 32" MIN. 2x6 CAP 2x6 RAIL CAP 36" FROM DECKING MIN. SPINDLES 4" MAX OPEN 4x4 POST (DO NOT NOTCH) 6' o.c. MAX RIM / BAND JOIST WITH 2 CARRIAGE BOLTS & WASHERS THROUGH POST & BLOCKING 4x4 POST RIM / BAND JOIST LANDING RUNNER OPEN TREAD - 9" CLOSED TREAD - 9.75" to 10.25" RISER 8.25" MAX. STAIRS OVER 30" IN RISE REQUIRE A CLOSED RISER TYPICAL STAIR DETAIL - NOT TO SCALE 2x4 POST GUARD / �4" GAP MAX. 5/46 DECKING POST BLOCKING PT BEAM TYPICAL RAILING DETAIL -NOT TO SCALE _Tjy_T6" PORCH COLUMN 5/4x3.5" RAIL CAP ' 36" FROM DECKING MIN. 1x2.5" RAIL GUARD (TYP.) 1x1 SPINDLES 4" MAX OPEN I I 4" GAP MAX. I � 5/4x6 DECKING PT BEAM ALTERNATE DECK RAILING DETAIL -NOT TO SCALE TYPICAL LEDGER BOLT PATTERN DECK JOIST JOIST HANGER (SIZED TO JOIST) EXISTING STRUCTURE 1/2" DIA. x 6" LAG SCREWS 6" o.c. or EQUAL I I EXISTING 2x BAND JOIST i TEXISTING ', FOUNDATION i TYPICAL LEDGER DETAIL - NOT TO SCALE LEDGER TO CONCRETE 3'Min Slaecmver TYPICAL POST / FOUNDATION CONN. • SIMPSON STRONG -TIE OR EQUAL IT IS A VIOLATION OF LAW FOR MY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR TO ALTER AN ITEM IN MY WAY. IF AN ITEM BEARING THE STAMP OFA LICENSED PROFESSIONALIS ALTERED, THE ALTERING ENGINEER. ARCHITECT, LANDSCAPE ARCHITECT OR LAND SURVEYOR SHALL STAMP THE DOCUMENT. ANU INCLUDE THE NOTATION 'ALTERED BY -FOLLOWED BY THEIR SIGNATURE, THE DATE OF ALTERATION, AND SPECIFIC DESCRIPTION OF THE ALTERATION. 4" OPENING MAX. 32" MIN. 2x6 CAP 2x6 RAIL CAP 36" FROM DECKING MIN. SPINDLES 4" MAX OPEN 4x4 POST (DO NOT NOTCH) 6' o.c. MAX RIM / BAND JOIST WITH 2 CARRIAGE BOLTS & WASHERS THROUGH POST & BLOCKING 4x4 POST RIM / BAND JOIST LANDING RUNNER OPEN TREAD - 9" CLOSED TREAD - 9.75" to 10.25" RISER 8.25" MAX. STAIRS OVER 30" IN RISE REQUIRE A CLOSED RISER TYPICAL STAIR DETAIL - NOT TO SCALE 2x4 POST GUARD / �4" GAP MAX. 5/46 DECKING POST BLOCKING PT BEAM TYPICAL RAILING DETAIL -NOT TO SCALE _Tjy_T6" PORCH COLUMN 5/4x3.5" RAIL CAP ' 36" FROM DECKING MIN. 1x2.5" RAIL GUARD (TYP.) 1x1 SPINDLES 4" MAX OPEN I I 4" GAP MAX. I � 5/4x6 DECKING PT BEAM ALTERNATE DECK RAILING DETAIL -NOT TO SCALE