2014-224 TOWN OFQ UEENSBURY
IFVO742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20140224 Date Issued: Friday, April 15, 2016
This is to certify that work requested to be done as shown by Permit Number P20140224
has been completed.
Tax Map Number: 523400-289-020-0001-035-000-0000
Location: 72 MELDON Cir
Owner: BARBARA J VANDERKLISH
Applicant: BARBARA J VANDERKLISH
This structure may be occupied as a:
Deck
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the (---- ApP 4 ,Ot
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140224 Application Number: A20140224
Tax Map No: 523400-289-020-0001-035-000-0000
Permission is hereby granted to: BARBARA J VANDERKLISH
For property located at: 72 MELDON Cir
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: BARBARA J VANDERKLISH Deck $12,000.00
72 MELDON Cir Total Value
QUEENSBURY NY 12804-0000 512,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
ADVANCED ENTERPRISES. LLC
PAUL ZEMANEK 791-5767
191 WARREN St
GLENS FALLS NY 12801-0000
Plans&Specifications
2014-224
DECK 320 sq ft
$50.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday, June 23,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town Quee buy y un 23,2014
SIGNED BY a for the Town of Queensbury.
Director of Building&Code Enforcement
.---- -. C{ ' „'It
Town of Queensbury Building & Codes office use Only 1 2014
ACCESSORY STRUCTURE APPLICATION Received:
L
tpx Ma. ;; N Or } c -�nrW�,a0-/-3c
A permit must be obtained before beginning construction
Permit No:3 D�.�1Nv _-
For any structure other than residential principal structure(house)to include, but Permit Fee: Owed
not limited to: garage, shed, dock deck, carport, pole barn, greenhouse, etc. Site Plan No.:
Refer to Informational Brochure No.3 Accessory Structures-Sheds/Fences
//rTaDate 5/2'Y Ge7/ Applicant //i5-
Tax
x Map ID 3$ Address /92 Lv4✓,' ?
Zoning Z sy, - l/ .�f /-Z// /' 12610/
Phone
Owner 77a•-7 �f��rr�Vis 'll Contractor/Agent %c4 e l lie.--,79//1"e" L2'
Address 7Z ,'+I2/c/Al i ; /i' Address /52// e/
`dvei'ryh�, /(//u /71Y /1/ /1742/'
Phone Phone 3/cf 717 — Y'
Contact Person for Building&Code Compliance: API S" Z.P.lx,st-e /C Day Phone: )7,/-3,76-.2
Building Street Address: 71 fr2 e/O 'r7
Subdivision Name: Lot#: /9 Historic Site: Yes A/No
Estimated cost of construction: $ / 21U6"4:2
Are there any other accessory structures on property? If yes,please list:
Type of Construction:
Check all that apply Please indicate measurements as required below
1st Floor sq.ft. 2nd Floor sq.ft. Total sq.ft. Height
Boathouse
Boathouse with Sundeck
Deck 32 G 320 7
Detached Garage(#of cars_)
Dock
Pole Barn
Porch-Open
**Porch-3 season,Covered, Enclosed
Shed
Other Accessory Structure(s)
**Considered floor area&must comply with FAR(Floor area ratio) requirements if located in the Waterfront Residential zone.
Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256
Please include two(2)sets of the following documentation with the application fee:
1. Accessory Structure Application
2. Plot plan drawn to scale with the use of a survey map, if possible[40 scale-1 inch=40 feet]
a) Indicate proposed structure, showing setback dimensions from all surveyed property lines
b) Show location of all existing structures on the property
c) Show location of water supply(well or water lines)
d) Show location and configuration of septic disposal system or sewer line
3. Structural Drawings to include: Floor Plan;Foundation Plan;Cross Sections; Elevations
4. Registered Architect or Engineer's Stamp (signed & sealed) under the following circumstances: Residential addition or alterations
with construction costs over$20,000;Any commercial construction
Other Notes:
1. Changes to Plan -Any changes prior to or during construction will require submittal of amended plans [review and re-approval are
necessary].
2. Withdrawn Permits -20% of the initial fee is retainable by the Town of Queensbury. No fee is refundable after 1 year from initial
application date.
3. Additional Review-All Applications are subject to Zoning Administrator, Code Compliance,and Structural plan review
CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL)
Residential Building Code
• New driveway requirements for structures located over 300 feet from main road;
• Spray foams are allowed to be exposed in rim joist box area only, must be covered by 15 minute thermal barrier all other areas;
• Protection against decay requirements;
• Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps;
• Vent stacks must be 18 inches minimum above roof for all structures
New Electrical Requirements
• Arc fault breakers required in all habitable spaces for receptacles;
• GFI protection for all other receptacles in kitchens, bathrooms,garages, and unfinished basements;
• All receptacles must be tamper resistant;
• Carbon Monoxide detectors must be located within 15 feet of sleeping area;
• All corrugated stainless steel piping must be bonded to the common ground for electrical service
New Energy Code Requirements
• Blower door tests required by credential contractor or structure inspected by air barrier supplier and certified compliant;
• Programmable thermostats required;
• Lighting must be 50%energy saving light bulbs;
• .Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit;
• Res Check inspector's checklist must be available at time of insulation inspection
Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the
application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be
performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also
understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to
issuance of a certificate of occupancy.
✓I have read and agree to the above Print Name: 14" �: <-
Signature: •
Date: `fflr
Town of Queensbury Building&Codes Accessory Structure Packet 518-761-8256
Residential Final Inspection L� �G 6 L
Inspection request received 4'0-0/
Name J- ,J'1 I/(zil(.f r/( S/4 spected on lG f/.S D-ote,
Location ii Arrive pm
Permit No. 6rcAO/q-,4c14 Inspector's Initials _C.1\--I6)
Type of Structure 3),o.s.r . iff
Yes No N/A Bathroom Fans, if no window
4" Building Number Address visible from road Plumbing fixtures
Chimney Height/ "B"Vent/Direct Vent Foundation insulation to floor/ Sticker on Panel
Location
Fresh Air Intake Duct work sealed properly/ Blower Door Test
Certification
3" Plumbing Vent through rm 18" Floor truss, draft stopping finished basement
Roof Complete/ Exte . r Finish Complete 1,000 sq.ft.
Platform at all exterior Emergency egress below grade
Handrail 4 or more risers Gas Furnace shut-off within 30 ft. or within line
Guards at stairs, decks, patios more than 30 " of site
above grade Oil Furnace shut-off at entrance to furnace area
Guard at stairwell at 34"or more Furnace/Hot Water Heater operating
Guard at deck, porches 36 " or more Low water shut-off boiler
Handrail Termination at Newell Post or Wall Relief Valve(s) installed /Heat Trap/Water
Interior/Exterior Railings 34 "to 38 " Temp 110
Deck Bracing/ Handicapped Ramp Compliant Enclosed Stairs Sheetrock Underside minimum
/: Gypsum
Grade away from foundation 6 " with 10 feet Basement stairs closed rise+ 4 inches
6" clearance to sill plate Garage Floor Pitched
Gas Valve shut-off exposed /regulator 18"above
grade Garage fireproofing //. hour fire door/door
closer
Interior privacy / trim /doors/ main entrance Gas Logs in Sealed or Glass Enclosure
36 "
/
Bathroom / Kitchen watertight Final Electrical: Energy Saving Light Bulbs 50%
Safety glazing/ Window in stairwells safety Final Survey Plot Plan
glazing Arc Fault Breaker Habitable Spaces /Tamper
Interior Smoke Detectors/ Carbon Monoxide Proof Receptacles
Detectors Flex Gas Pipe Bonding
Every level: Every Bedroom: As Built Septic System / Sewer Dept. Inspection
Outside every bedroom area: Sticker
Inter Connected: Site Plan /Variance required
Battery backup: Flood Plain Certification, if required
Attic access 30" x 22" x 30" (height) in Okay to issue Temporary/ Permanent
accessible area
Certificate of Occupancy OR01
Crawl Spaces 18" x 24" access, 1 sq. ft.-150 sq. Certificate of Compliance
ft. vents
Yes No N/A
Comments: '
Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256
Foundation Inspection Report
Office No.(518)761-8256 Date Ins6 tion r-' .-st r---'• -d: ( (P L(
Queensbury Building&Code Enforcement Arrive: ' . : 7 Depart: .//t",,�'!"r .r.
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: AD1/wo' ` i.11-'�wt SC 1«- PERT#: 1
LOCATION: �} (`, c-c(' INSPECT ON: 17/II
TYPE OF STRUCTURE. (� ��
Comments
Y N N/A
Footings qt" Fi_f
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
...
la
GOILIMI Now
II / /
.'
I ..
I I
•
t /
/Existing Home
I 1
TOWDNemIn(qOtteFdsQaxUEcEnti1/4ElitJTaSbtrBeoEUncol7crYnosmirpuleiadn ac:
.
n
3/4' BaUster Al. .
1 / iaiditCa°c °rgniciUt4le:L :
ii lans arid specifications are in
1/4' gsaipte decking 5.25'X1.125
•
/
I
, ' 'Lill ccrnpliance with the Building Codes of
lew Ytork Stale. ,
• 1 _
_ —
______ .-___,-,--__...--__--- • _:-_—_--- ..
, ....,, 1 .
. -
. ..
crush block req. but not
shown 1 every 6' sec tion 2 on 8' section
2X12 dbl. Pt length of deck • ,
. I
Hurricane clips every other Joist /
1/2"x6.5' carriage bold Gal two each post ,i
//,
,
,
/
, r:ioa
1T1 1
•
Ho. Rookgonform Cot.,
. •
12Tube 3 pc i4 bar
1 ' 7dr-leri-{...
' /'
/ '
i i
, co.11•••..14111• •
0 N•
7////-- 1/2'x8' Jay bolt post In base
--,, Samisen AB6G or Equivalent /
9 CM ',/,...:.f."-/."7
//5
—1, Grade
I " I
—
. -
I I ,
/ .............-
Dacl:72 1.4,10on Placa
\ i k/..'4/-0-it.-,!-,„6
-
evoombuty NY
003 /T 1........- .-.' /
‘1' I
—
wide base for load distribution
I ( •
/1...... ......
[.....-
1 I /
I // ....
•
0/7/2014 E 11
1,4,,
. ,,,...
\........_ ,
MAP REFERENCE
HILAND CROSSINGS
A SUBDIVISION MADE FOR
THE MICHAELS GROUP
BY VAN DUSEN & STEVES
DATED APRIL 15, 2009
LAST REVISED OCTOBER 15, 2009
FILED IN THE WARREN COUNTY
CLERK'S OFFICE ON NOVEMBER 6, 2009
N al L u s e
&'
I
Land Surveyors
169<Haviland Road Queensbury, New York 12804
518 792-8474 Nen York lAc. No. 50135
Scale 1'=20'
s
ISI
, i
r
i
t
�
t
ISR
�
i