Loading...
2014-279 TOWN OF QUEENSBURY AFli742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20140279 Application Number: A20140279 Tax Map No: 523400-301-008-0001-001-000-0000 Permission is hereby granted to: RICHARD & BARBARA ZUCCARO JR For property located at 56 HELEN Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RICHARD & BARBARA ZUCCARO Septic Alteration Residential 56 HELEN Dr Total Value QUEENSBURY,NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2014-279 Res. Septic Alteration $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,July 02,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town f Quee bury61 I :e t ••S l 02,2014 Ar SIGNED BY - for the Town of Queensbury. Director of Building&Code Enforcement OW, TOWN OF QUEENSBURY 417 742 Bay Road,Qucensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20140279 Date Issued: Tuesday, July 15, 2014 This is to certify that work requested to be done as shown by Permit Number P20140279 has been completed. Tax Map Number: 523400-301-008-0001-001-000-0000 Location: 56 HELEN Dr Owner: RICHARD & BARBARA ZUCCARO JR Applicant: RICHARD & BARBARA ZUCCARO JR This structure may be occupied as a: Septic Alteration Residential By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the (---- fil4 property owner of the responsibility for compliance with Site Plan, a,, Variance, or other issues and conditions as a result of approvals by the Director of Building& Code nforccmcnt Planning Board or Zoning Board of Appeals. Office Use Only Town of Queensbury Building & Codes Received: SEPTIC DISPOSAL PERMIT Tax Map ID: 91 . - 1 - I Permit No.. A permit must be obtained before beginning construction Permit Fee: $ 1 L', 'C Approvals: k'. / JUL 02 2014fApplicant: ICA ,ct C C a ^O Installer/Builder Sfr ' 4-A-r��f e J eritf< - Address: S"6 /-1e l& .,/ Df ire Address A . go Y-d 2 2 't D114-eewS Q`'1/4),. ..%).) /4-/!r /V /24err/ Phone: Phone 792--72 r7 Owner: licit 7 4 Cc a tG Location of Installation Sl //e-' A"/ Address: Phone //�� � //// Contact Person for Building&Code Compliance: O i y.F_ b7`�LIJ-/ Day Phone: 7 -376iv Residence Information: r�// Year Built #of Bedrooms x Gallons per bedroom =Total Daily Flow 1980 or older x 150 = Garbage Grinder installed? Az) 1981-1991 x 130 = Spa or Hot Tub Installed? /1-'0 1992-Present 7 x 110 = y 4/0 Parcel Information: �/ Topography X Flat Rolling Steep Slope %Slope Soil Nature Sand Loam Clay _Other Groundwater At what depth? ,v4 Bedrock/Impervious Material At what depth? N/' Domestic Water Supply Y. Municipal...... Well(if well,water supply from any septic system absorption is ft.) Percolation Test Rate- 1 - S per minute per inch(Test to be completed by a licensed professional engineer or architect) Proposed System for New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). Tank size /2-'- gallon(minimum size 1,000 gallons),add 250 gallons to size of septic tank for each garbage grinder,spa or whirlpool tub System Type: Absorption Field(with#2 stone) Total length ft. Each trench X See age Pit(S)(with#3 stone) How many? Size? Alternative S— yst m Bed or other type? 2// 2 5 Holding Tan System Total required capacity? Tank size? #of tanks? NOTE: 1)Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency-see Certified Electrical form on Town website; 2) Effective as of March 23, 2006 Septic System-As Built Plot Plan: The Building Department will no longer allow systems to be covered until such time as an As-Built Plot Plan is received and approved by the Building Inspector. The installed system must match the septic system layout on file, There will be no exceptions. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. /I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Print Name: (3 re-c`� Date: V Signature: �— �z Date: / Town of Queensbury Building&Codes Septic Disposal Permit 518-761-8256 /DSC Tib 1l : 3,o Septic Inspection Report Office No. (518)761-8256 Date Ins•- •on . -1 -•: Queensbury Building &Code Enforcement Arrive: - Opt I' aim 742 Bay Rd., Queensbury, NY 12804 Inspector's Initia p tI NAME: P •�IT NO.: I ir/ 7 LOCATION: g(c. t I'. .PECT ON: 7/Ic/i q RECHECK: / Comments and/or diagram Soil Type. - -- .:m/ Clay Type of Wateri -II Water Waterline separation distance _ 1 E ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A [150'to well required if NO] Absorption Field: Total length ft. Length of each trench Depth of trenches ; ft. Size of Stone Z Seepage Pits: Number Size: x Stone Size: Piping Size Ty Building to tank � - t3 L Tank to Distribution Box Distribution Box to Field/ Pit f 4-11` hD(2--j6 Tp \-k A—3 i ' - Opening Sealed: ✓Y—N End Cap —> Inlet/Outlet Pipes&Baffles N Manholes 12"or less below grade N [provide extension collar if Yes] Y, N Location/ Separations Foundation to tank V ft. Foundation to absorption ' k ft. Separation of Pits l ft. Conforms as per Plot Plan , ✓Y N Engineer Report and As-Built : Y N ETU Maintenance Contract _Y N provided Location of System on Property: Front R r Left Side Right Side Middle Fron Middle Rear S stem Use S s: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Buliding Codes Forms\Inspection Forms\Septic Inspection Report 03 29 10.doc SEPTIC PLOT PLAN I HAVE SEEN OR OBSERVED ALL OBJECTS SUCH AS HOUSES, WELLS, TREES, FENCES, ETC SHOWN 0 IS DOCUMENT.I HAVE PERSONALLY MEASU 5LIQ_E SET F T THIS DIAGRAM. 7- 2 -7y SIGNATURE DATE CI TOWNOFr • . F?x.,11.'Q`r... //- IS Vi ,vve / .." _ ,.k N' N - 0Z nA a N ` 1 al N t‘i e � ,oGy s' ' r .\ CENTER PROJECT SERVICES - j 73 Sheridan Street, Glens Falls,NY 12801 .J Phone-518-796-2515 June 25, 2014 Project# 190 George Drellos Sanitary Sewer Services Luzern Road Queensbury,NY 12804 Re: Proposed Replacement Septic Rich Zuccaro—56 Helen Drive, Queensbury,NY Dear George: At your request we have reviewed your proposed replacement septic system design of the existing 4 bedroom house at 56 Helen Drive in Queensbury. As per our conversation the residence has an existing failed septic system. We have reviewed the proposed replacement septic system design and we agree that a standard absorption bed is acceptable. Based upon a design flow rate of 440 GPD and a percolation rate of 1 to 5 minutes, you will need 463 square feet of absorptive area. We recommend using a 20 ft wide by 25 ft long absorption bed with 4 — 20 foot long laterals, which will provide 500 sf of absorptive area. The absorption bed can be constructed with the existing 1,250 gallon septic tank, new distribution box, and 4 inch diameter perforated pipe and stone. The replacement system has been designed to accommodate a future additional bedroom as long as all fixtures are upgraded to water saving devices. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely, Thomas R. Cent- r, P.E.