2014-309 `/� TOWN OF QUEENSBURY
` } � 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140309 Application Number: A20140309
Tax Map No: 523400-308-017-0001-027-000-0000
Permission is hereby granted to: STEPHEN METIVIER
For property located at: 125 NORTHWEST Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: STEPHEN METIVIER Fireplace
125 NORTHWEST Rd Residential Addition $400,000.00
QUEENSBURY NY 12804-0000 Total varve $400,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
KATA PHUSIN DESIGN
11 SHALLOW CREEK Rd
OUEENSBURY NY 12804-0000
Plans&Specifications
2014-309
Res. Alteration- addition 986 sq ft, [south, west & east]; Fireplace - gas [NOTE-North addition and
Garage pending zoning board approval - fees refunded 8/5/2014 ]
$197.29 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,August 05,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of Qu nsbu fir T d ,August 05,2014
SIGNED BY G " for the Town of Queensbury.
FJ
Director of Building&Code Enforcement
Office Use Only
Town of Queensbury Building & Codes —77-:-----.--rt .--_ ._
• � 1 lug 1 ;Received:=---7--
I�1 �`-°'- :-Tax if 1308 , 13-1- h_PRINCIPAL STRUCTURE APPLICATIOIN?) 1Permit No.: /Ai- b i
A permit must be obtained before beginning constructlo 3ilL ; TAetal4ee: $P
' *par ran. $( - 612 ��
Please read: 'TB resolution 86-2013(1-28-2013): $850 recreation a forrnew fiveIDnio jrF�1�,#j^v /
units,including single-family dwellings,duplexes or two-family dwellings,.multiel ilyG &SSte�,P_laan No.:
dwellings, apartments, condominiums, townhouses, and/or manufactured and module `SubdiyisronNo.J
homes,but not including mobile homes. This is in addition to the permit fee.
Date JUNt 2f0, 2011-I Applicant TRAv\5 KLI NE p_el
Tax Map ID 308. 11 - I - 2-1 Address i1 SHAu-Ov3 CREE-K czO.
Zoning (1\f)R (rnootr2AI E DENS IN RES.) 9U1%EN5(309-`I , roy 17804
Phone/E-mail 510 361-2541 i TAM IS
KATn VHUS, 31)C5IHN. Corn.
Property Owner STEPHEN PIENkVlEt2 Contractor/Agent KATti PHUs1n1 ntStt,14t
Address t7-5 NIOR'CH1n1-51' 'Rt). Address It 3\V\U-OW CREEK '2D.
uEVAS'BuR11 MN fzhh09 00r-E-A15(3uk'-1 , ik14 121504 #
Phone/E-mail (T1s) ( OS - 228e\ Phone/E-mail (518) 3 61 - 2.S`12.
Building Street Address: ITS N OIZv H w tSt ROAD �1X
Subdivision Name: Lot#: Historic Site: Yes No
Estimated cost of construction: $ 9 CC J 000 r -,
Type of Construction: °I
) (� '(,((v �f
Check all that apply (Please indicate measurements as required below. 7f:y:l112:
c c
0d is m 1st Floor 2nd Floor Other Total
? a a (I+AASEM6NT Sr
7T �,Nar.�s
�3
Single Family X 11 IS 0 �v, y} • ; 3b (9 21 G
' Two-Family AO-Li✓ G
epGCe TO tmATC,1-1 E`F1S--.
Multi-Family(#of gIDake Lr NE
units_J
Townhouse etb �
Business Office /` SQ}'�
Retail-Mercantile oicrsJ;0!
C' •
Factory-Industrial - -
23
Attached Garages(#..._a ?i- x 02 / 5)-VA 562 grf 1°2
Other /
Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256
•
,
If commercial or industrial indicate name of business
Proposed use of building or addition AOD1T10rJ _ VvI RSI R BE'06d00 Yh I.
Lm V N(n 2U0Yt1
Source ofheat(circleone) Gas Oil Propane Solar Other Nyere 10
4ft7MGYtrnitt.
Fireplace-complete a separate application for'Fuel Burning Appliances&Chimneys° X Yes _No
Are there structures not shown on plot plan? N 0
Are their easements on the property? N
Site Information -
a Dimensions or acreage of lot • 0.1-6 A GEES
b. Is this a comer lot? • YES
c. Will the grade be changed as a result of construction: _Yes No
d. Public water or Private well WeA1
e. Sewer or Private Septic System �r�'
Value of all work to be performed(labor and materials) $ 4 00, 000
Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval. I certify that the application, plans,and supporting materials are a true and complete statement/description of the
work proposed,that all work will be performed in accordance with the NY State Building Codes,local building laws and ordinances,and
in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a
certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed Date: 61 r
2to'IL1
I
FOR OF ICE USE ONLY: -
Operating Permit Issued: _Yes _No
Occupancy Type:
Construction Classification:
Assembly Occupancy Limit:
Special Conditions:
Town of Queensbury Building&Codes Principal Structure Packet - 518-761-8256
_1 Town of Queensbury Building & Codes Received:
Tax Map ID: .r3R $ , l>- I-at>
FUEL BURNING APPLIANCE & CHIMNEY`APPLICATION __Permit No.: 17 — i a"
--�--- -� �r I I
JUL 1 4 2014 l Mil I
Application is hereby made to the Building & Codes Office for the issuanceof a Building & UselPermitipursuant to the NYS Are Prevention &
r r
Building Code. The applicant or owner agrees to comply with II applicablella..,.. . dihances,;regulations and all conditions that are part of these
requirements and also will allow all inspectorsp pelf 'm"eq`it .in pe v,n .5
to enter premises-to orm�r wired"ins ctiarLS
Important Note To Applicant: Rough-In and Final Inspections Are Required:
Date (D/2(v/l`1 .
Owner STEPHEN) IMET1v1f)2. Installer/Builder KA171 PHUSIA) 1ECItAl
Address IZS PoORTNWE.ST RD • Address i1 cuntLOt,J rpF K
Qt)EF-r.\SBURY, Ni 1221011 Qur6NSC3oP-41 /UN Iz O14
Phone (5-1 ,") 605- Z259 Phone (514.) 361 - 26N 7
Location of proposed construction and/or installation: 125 NognkkApa t RD •
Contact Person for Building&Codes Compliance: TRAV 1S k LI NF
Subdivision Name:
Fuel Burning Appliance Information Wood Coal Pellet Gas Oil
Stove
Fireplace Insert
Fireplace,factory built' X
Fireplace, Masonry
Furnace,(Garage Only) •
i
'If Factory Built,Please Provide: Manufacturer Name: Ht of &z (A I-0 Model No. R ED110 51
Listed By: Number:
Chimney Information
Masonry" 'check one Block _Bride _Stone
Flue "'check one Tile Steel _Size in Inches
Material ',check one _Double Wall _Triple Wall _Insulated _Direct Vent _Chimney Liner
"If Non-Masonry,please provide: Manufacturer Name: Model No.
Signatures:
Print Name: TiA\INS kLINE-
Signature: ` Date: 6/2‘/ 11-1
ADDITIONAL NOT{CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION &BUILDING CODE
AND/OR MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING
REQUIRED INSPECTIONS.
Please consult the manufacturer's RED40ST
H EAT&6 LO. installation manual for all details and
no one builds better fire requirements before making a final Linear See-Through
design layout decision. Direct Vent Gas Fireplace
gm MODEL. U'FRONTsWIDTH' MBACK,WIDTHa IIIIIHEIGHT21.111 IIIMIDEPTHEM MGCASS SIZE
Actual Framing Actual Framing Actual Framing Actual Framing
RED4OST 40-1/16 x 13-3/16
48-1/8 50-1/4 48-1/8 50-1/4 46-3/4 46-3/4 18-1/8 17-1/4
50-1/8"[1273]
25-1/16"[637]
1[460] O. I■"
[460] �,,_
p9-1/1[2�6" pm_ _
]
Top
4 52"[1321]
4 i
21,E
13-3/16" II - II- [533]
[335]
10-3/4'II Ilk
[27
14— 42-3/4"[1086] J 4"
[102]4-3/4"
14-- 48-1/8"[1222] [121]
Front
H1368
loi11
r IIII 1 I 1[178]
1\11I I
42-15/16" 146-3/4"
[1090] 1 [1187]
3-3/4"
[95]
�B t1
8-1/2" — 17-1/8"
I
1-1/2" [216] I~ [435]
[38]
Left Side Right Side
Additional information can be found online at www.heabwlo.com
MINIMUM FIREPLACE CLEARANCES FRAMING DIMENSIONS
AREA j TO COMBUSTIBLES
V 'O"
CLEARANCE TO CEILING 31 4254
COMBUSTIBLE/NON-COMBUSTIBLE FLOOR 0
BEHIND APPLIANCE 1 HI ,.
SIDES OF APPLIANCE 1
FRONT OF APPLIANCE 36
APPLIANCE LOCATION
r_1,4 1
8 r[4]46-3/4^
[914] [118 `\`j?
—I 48"[1218] I 50-1/4"[1276] YY//%%�W
n
m �j
17-3/4[451] CLEARANCES TO COMBUSTIBLES
of
fn ;-ib Q Fireplace Opeeasure from ning
36" l_I
[914]
j
IlB?]
WALL PENETRATION
[ga
Do not packwith 100-Al I
insulation or other ;--eu �
materials
i
ta kt$1
i12" 44..111..
♦ /
�.
8-3/4.lUI
/ o Iz�
hl[
MANTEL PROJECTIONS
To CEa NG
Shows center of vent framing hole TOCEIDNG
for top venting.Center of hole is 1"593/4" above center of horizontal vent pipe. }
1/ 1�—r}}I 1 �_
`, iizia tr
rti 11 9 31
LEG/WALL PROJECTIONS I `"1p . �_—11112
'"w
� 1ie
�i bl6ustibe 11 41111
O _ motel leg zone Measurement from.
rom CI Measurement from
�� top edge at opening alp edge of opening
TOP VIEW Combustible Mantels Non-Combustible Mantels
All measurements in inches
A --7'rrtin
q•Men Product information provided is
I--Irep^ r PRODUCT LISTING CODES not complete and is subject to
OpeUnlimited change without notice.Product
` US ANSI Z21.88b-2008 installation must adhere strictly
•6'min to instructions accompanying
CAN CSA 2.33a-2008 product to avoid risk of fire and
�� UL3078 Potential injury.
Additional information can be found online at www.heatnglo.com �/��
HEAT&GLO. A brand MN�wwHo eTechnc&oogrese e(Yymlmm
rickezc
. Queensbury Building & Code Enforcement - Residential Final Inspection —I --
Office No. (518) 761-8256 Arrive: am/pm Qap�rt: 1 A 1 �/prrl `
Date Inspection request received: 6%1 2pdS Inspector's Initials:
NAME: NV \Vtt.,V PERMIT#: It 301
LOCATION: 125 NOX th,ntal-Q.21• DATE: 91117.-C45
TYPE OF STRUCTURE: *Ja/f,vtelac t )
Comments:
Ye:Ao N/A_
4" Building Number Address visible from road �1//
Chimney Height/"B"Vent/Direct Vent Location
\ _53L3Fresh Air Intake IYQ t tt;. 1-2-74.3 inch Plumbing Vent through roof minimum 18 inches I
Roof Complete/Exterior Finish Complete
Platform at all exterior doors >r
Handrail 4 or more risers „
Guards at stairs,decks,patios more than 30 inches above grade v
Guard at stairwell at 34 Inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Wind in stairwells safety gl ing
Interior Smoke D ors/Carbon MgnoxidyDeteegq66rs
very level: Every Bedroo(n: v
Outside every bedroom a V
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area ,
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below gradeVie
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating V-
ow water shut-off boiler
R -
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum //'
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding V
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification, if required
Okay to issue C/C or C/O[Temporary ernanentdill
L:\Building&Codes Forms\Building&Codesllnspection Forms1Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10,Revised 04/13/11
Queensbury Building & Code Enforcement - Residential Final Inspection
C
Office No. (516) 761-8256 Arrive: am/pm De art:G��_` am/pm
Date Inspection request received: Inspector's Initials:
NAME: Mei t:V'f. PERMIT#: 2x514 `307
LOCATION: flS D 't. C DATE: C/l i,//fl
TYPE OF STRUCTURE: G s •:.—...
Comments:
Yes No N/A_
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
-
Fresh Air Intake
inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers 1/
Guards at stairs,decks, patios more than 30 inches above grade tVe
Guard at stairwell at 34 Inches or more !✓/�V
Guard at deck,porches 36 inches or more Y
Handrail Termination at Newell Post or Wall /
Interior/Exterior Railings 34 inches to 38 inches V,
Deck Bracing/Handicapped Ramp Compliant W
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 38 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety •lazing
Interior Smoke Defectors/Carbon Monoiaetectors
Every level: V Every Bedr*i: ✓
Outside every bedroom ea: t/
Inter Connected:
yea:
backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,ifno window ./
Plumbing fixtures r 2__
Foundation insulation to floor/Sticker on Panel {
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft. r7
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site a/
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating V
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum / ' M I
Basement stairs dosed rise>4 inches ✓ (y�+la4,--
Garage Floor Pitched >i, _ n,, ,
Garage fireproofing/ hour fire door/door closer �� `�L��JvC.
Gas Logs in Sealed or Glass Enclosure -
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding /
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required /S\
Okay to issue C/C or C/0[Temporary/Permanent]
L:18uiiding&Codes Forns\Building&Codes\Inspection Forris\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10,Revised 04/13/11
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/p rt:C/ �am/pm
Date Inspection request received: Inspector s Initials:
A + S
NAME PERMIT#: \
LOCATION: - ' , ,1r A.— DATE: 12 ( rT
TYPE OF STRUCTURE: A-n4)
r Comments:
Yes No N/A_
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing I Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Eveedroom:
Outside every bedroom B:
Inter ConnectedBattery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss, draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Fumace shut-off at entrance to fumace area
Fumace/Hat Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum fh"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/% hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
I r u. s 9 k16 S'k5Actrioe. et n e to er
L:U3uilding&Codes Forms\Bulding&CodesUnspection Forns Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08; Revised 12/22/10,Revised 04/13/11
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256
Framing 1 Firestopping Inspection Report
Inspection request receiv-d:
Name: Inspected on: l
Location: s ►` ' ,\ . Arrive: I a.m. p.m.
Permit No.: 7 t aCi9 Inspector's Initials: Sh
TYPE OF STRUCTURE: J
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"m i urn
Jack Studs/Headers
Truss Specification P avid-
t hg I Bridging
Joist
Joist hangers
JackPosts/Main ail ms
oicypExterior sheeting nand properly
12"O.C.
Headroom 6 ft.8 in.
•
Stairwells 36 in.or mire
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches I Holes/Bearinl Walls
Metal Strapping for Notc es Top Plate
1 'A(w) 16 gauge(8) 1,D nails each side
Draft stopping 1,000 sq. .floor trusses
Anchor Bolts 6 ft.or les- on center
Ice and water shield 24 nches from wall
Fire separation 1,2,3 h i ur
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in c.vity min.
Garage Fire Separation
House side'A inch or 5 t inch Type
Garage side 5/8 inch Ty.e X
Ceiling/wall
Windows Habitable Space/ :-droo s
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing I Firestopping Inspection Report
Rough Plumbing / Insulation Inspection Reportd /
Office No. (518) 761-8256 Date Ins tion r nest received: /, g, s� GG''
Queensbury Building & Code Enforcement Arrive:,tel
a /pm
742 Bay Road,� Queenshury, NY/12804 Inspector' I ti Is: ,. A.
NAME: )/� 5 L�f/�/ite.� /�e4i'44 PERMIT it: /I --
LOCATION:
/
LOCATION: `d,CAL- INSPECT ON: !da i ;, . 40,ie /5
TYPE OF STRUCTURE: f .to s4e �1re.Q (coU
Y N N/A
Plumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I. for for 15 minutes
Insula ' Residential Check/Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
•
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS: -f 51A \_ - UJ tl" 4 Utr
60th - ed
Rough Plumbing_Insulation Ins I:.ct _02 0513
Town of Queensbury Building & Code Enforcement C
Office No. (518) 761-8256 �5 —1 an--
Framing I Firestopping Inspection Report KurriK
Inspection request received: /./� . 2�t(] �1��[
Name: S 6,1 Cr/IG1J7�'P�99 r �`'N Inspected on: / n- Cl.C7 5
Location: �d1wtr KC� Arrive: COS a.m.l p.m.
Permit No.: aO/`f -30 Inspector's Initials: 0 .17
TYPE OF STRUCTURE: NM pLao'
Y N N/A COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '%(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3_,_4 hour
Penetpis_...p
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade4/ I
/,Design Professional Sign-off,if required
I �
Framing/Firestopping Inspection Report
Town of Queensbury Building &Code Enforcement -MAYS /0 to/
Office No. (518)761-8256 /� i -,\
Framing I Firestopping Inspection Report l
Inspection request received: 11 yy
Name: �P.A-1 p,f Inspected on: /—afa JJr
Location: /a b N ►1 [.OEs.{' Arrive: . 2- " a a.m.1 p.m.
Permit No.: - 4 Inspector's Initials: a
TYPE OF STRUCTURE: °S is j-{-, Wir
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30°minimum
Jack Studs/Headers
Truss Specification Provided
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2(w)16 gauge(8) 160 nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Itoja_stumik
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation 0. C7)
House side'/:inch or 5/8 inch Type X t���
Garage side 5/8 inch Type X
Ceiling/wall 6 —
Windows Habitable Space/Bedroom_
24 in. (H)
20in. ` ,
5.7 (W)sf above
above/below grade
5.0 sf grade
s
Design Professional Sign-off, if required
Framing/Firestopping Inspection Report
I
Town of Queensbury Fire Marshal
01,4.1 742 Bay Road
Queensbury,NY 12804
761-8205/761-8206
fax 7454437
Factory Built Gas Fireplace/Stove Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed. �,�
Permit# I -3o R Schedule Inspection I I la I ' r Timely l Ppm anytime Inspector t ' `r (
Name { 1,t.TEJtt 2-- Address((l1Ian IVDii'1.�..1t=.5' r ID Rough In Final
V
Appliance Manufacturer t.•N'MA1 `,.tvS1A-al) Model# \.)W Pi v ---7f/
l t) ` Wet
Direct Vent Factory Built Chimney Y Flue Size In( Double Wall Triple Wall Insulated V &fir
r
Yes No N/A Comments
Floor Protection 'I)-2 X ujuu n 77*��t'
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase X ;J.la. ! '
Wall Penetration
Vent Clearances to Combustibles I Iii X
Vent/Chimney Termination
Chimney height must be 3 feet above roof I I
penetration;2 feet above any combustible ja.
construction within 10 feet
Gas Shut-Off Valve f
Combustion Air
Hearth Extension (if any)
(i
Mantel - ,s 4, v 0-61-
Height
t(slHeight above f/p opening
/
/
Witness Operation / `/
Tank Placement(if LP) 6ari E.
CO Detection / et.
. „,,,,,- - (10 ,CSST Bonding d
White—Building Dept Yellow—Cost mer Pink—Fire Marshal
Town of Queensbury Building &Code Enforcement ?—/v
Office No. (518) 761-8256 ��
Framing / Firestopping Inspection Report
Inspection request received:
Name: m r Inspected on:
Location: I%5' N b 1"-{'h0e-s Arrive: _ t 4 a.m./p.m.
Permit No.: / c3D9 n Inspector's Initials: /�f i
TYPE OF STRUCTURE: '"1 h
— Y N NIA COMMENTS:
Framing �/
Attic Access 22"x 30"minimum c//
Jack Studs/HeadersVTruss Specification Provided `�///
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour ' r `
Firestopping ' )
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing /Firestopping Inspection Report
Rough Plumbing / Insulation Inspection Report ) g=oo - too
Office No. (518) 761-8256 Date Ins ction r quest received:
Queensbury Building & Code Enforcement Arrive: :- dam/ppm
742 Bay Road, Queensbury, NY 12804 Inspecto 's Initial'
NAME: 0 Erni-\") \Ea_ PERMIT#: II-N-3 °‘
LOCATION: FOUR—H kx) E.5 c7i c) INSPECT ON: \Z- 11-1,—\
TYPE OF STRUCTURE:
-Zo Cs neo l4R-PAR
Y /4 N N/A
lumbing under slab
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent 11
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping ti
Air/Head
50 P.S.I. for for 15 minutes
Insulation /Residential Check/Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection_02 0513
Town of Queensbury Building &Code Enforcement (.3 Oct 4
Office No. (518) 761-8256
Framing / Firestopping Inspection Report
Inspection request received:
Name: Inspected on: Li--"—/
Location: JO tai— Arrive: a.m./p.m.
Permit No.: /*<-I-3o I Inspector's Initials: ,AJ__ �
TYPE OF STRUCTURE:
Y N/A COMMENTS:
.Fr`aming
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing/Bridging 1
`
Joist hangers V 1 A(�
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side''%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing I Firestopping Inspection Report
ro/a
9
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am//p
urpm Depart: / pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initial'' /
NAME: V11 &RN) I !'//r l PERMIT 17 -say
LOCATION: ) �0 r-j-h to€C'f-C9INSPECT ON: 9 -3/A/
TYPE OF STRUCTURE: R gs Add.
^'
Comments
Y N N/A
Footings
Piers
• :Monolithic
:tab)
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
poly wet areas under slab ri
• • :. oval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation r n erio /I xterio
R- Wc-i
Rough Grade 6 inch drop within 10 ft.
L:\Building &Codes Forms\Building&Codes\Inspection Forms Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: am/pm Depart:/6 7f m/pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials-
.
nitials / ` i
NAME: m CaAr .Q.lO PERMIT#:
LOCATION: ) 5 NO O(--kh W es INSPECT ON:
TYPE OF STRUCTURE: r`9-6 fro+ S'Ar
Comments
Y/ N N/A 3 co I to 95,3
Footings ` V
Piers Bn �
Monolithic Slab
Reinforcement in Place
The contractor is responsible for •
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Emulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM
acn
Foundation Inspection Report U
Office No. (518) 761-8256 Date Ins section; i, - e v'e
Queensbury Building &Code Enforcement Arrive: 4' l r• Depart: e•
742 Bay Rd., Queensbury, NY 12804 Inspector's Initia :
NAME: M ..Q..l.l2>,7-tQ�� j RMIT#: I -3 o 9
LOCATION: 9 , 1 'fr3 i- l.iv-exA-R d INSPECT ON: I-o`lo-l v
TYPE OF STRUCTURE: It,
Comments
Y J N N/A
Footings
Piers s7E mi
ce
Monolithic Slab � /
Reinforcement in Place js
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
4�Foun atiori/Wallpour ���s y L`r+ *WM—
Reinforcement in Place
Footing Dowels or Keyway in place LAD_ L-teQ i
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM
Foundation Inspection Report /
Office No. (518) 761-8256 Date Inspection request received: i TS
Queensbury Building&Code Enforcement Arrive: am/pm Depart: ° 4,r m/pm
elf
742 Bay Rd., Queensbury, NY 12804 Inspector's Initial
NAME: iYl Pfk cif PERMIT#: L
LOCATION: ! Q..< N((1Lt }"2 cn��S 7-720- INSPECT ON: ;
TYPE OF STRUCTURE:
Comments
N N/A
) Footings
J` Piers
Monolithic Slab VVV
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place �/ r(`���
Footing Dowels or Keyway in place J t C
Foundation Dampproofing Lile4 A —
Foundation Waterproofing l.C3izs-- A
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R •-
Rough Grade 6 inch drop within 10 ft.
L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/18/2013 2:44:00 PM
2__ey �'`tR`b0 /904_
m 8
24' RP5
1-1
R
239 ' 8
14'
II Second Floor
m 252 R' ro, 1$
NN N
1sWD/Bsmt Garage
lsWD/Fin Bsmt
First Floor
1649 ft2
1Q,
--- Finished Basement
3z, 225 R' 39
ti
RP5
748 R'
36'
51
SWIS : 523400
Print Key: 308 . 17-1-27
Comment : Sketch