Loading...
2014-471 � 11% TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140471 Date Issued: Monday, December 01, 2014 This is to certify that work requested to be done as shown by Permit Number P20140471 has been completed. Location: 62 MELDON Cir Tax Map Number: 523400-289-020-0001-032-000-0000 Owner: GARY A DOBERT Applicant: GARY A DOBERT This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property ( >) / // 2__.- owner of the responsibility for compliance with Site Plan, Variance, or c� G other issues and conditions as a result of approvals by the Planning Board Director of Building& CodeVEnfinent or Zoning Board of Appeals. TOWN OF QUEENSBURY 411" 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140471 Application Number: A20140471 Tax Map No: 523400-289-020-0001-032-000-0000 Permission is hereby granted to: GARY A DOBERT For property located at: 62 MELDON Cir in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GARY A DOBERT Residential Alteration $20,000.00 JUDY A DOBERT 62 MELDON Cir Total Value $20,000.00 QUEENSBURY NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency R.L. CHASE BUILDER RICHARD CHASE JR. 361-3656 20 MARION Ave SO. GLENS FALLS NY 12803-0000 Plans&Specifications 2014-471 Res. Alterations 620 sq ft finished basement $97.50 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, October 03,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o uee bury; rid Off;tober 03,2014 SIGNED BY ed. for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only 1 DATE .' 6 ) I Received / Tax Map ID � ! , t � Jr TAX MAP ID Permit No. � ermit Fee q4-70/6, nv ZONING Rec Fee for/ An;4.Site Plan # HISTORIC SITE Yes XNo Subdivision # SUBDIVISION NAME _ Lot# TOWN Ba RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWELLINGS,DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED & MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE. • APPLICANT •L. has?.Pi I U 1 Wet— OWNER v y. Tucty Ale_ ADDRESS �� e-1 i\ ♦� ADDRESS 30 Marto(I �! O r-`4ev►.S pt,/`S �w <- 4S(21) � ,-41 /A:0 PHONE/E-MAIL r L �5t;.0;IG�Gt-®.Aiycap,-R' ,am PHONE/E-MAIL ---CT(S- G 66' Soo CONTRACTOR Il. • Oita-S. t o COST OF CONSTRUCTION(ESTIMATED): $ ' ADDRESS: BUILDING ADDRESS: (e„D-- /`�e (CL-N C� 'c(t_ PHONE/E-MAIL I lI II;,�� CONTACT PERSON FOR BUILDING &CODE'S COMPLIANCE: �IGtia..1^CX G1(iGt S _Tr- PHONE 3G/-3�s� TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below New Addition Alteration 15t floor sq.ft. 2nd floor sq.ft. Total sq.ft. Height gle Famil (�j0 S' (0.(6) Two-Family kirksI��J (ouim ee,.f Multi-Family (# of units ) Crownhot e Business Office Retail - Mercantile Factory- Industrial Attached Garage (# of ) Other 1 Town of Queensbury Building&Codes Principal Structure Application July 2014 If commercial or industrial indicate name of business Proposed use of building or addition Source of heat(circle one) Gas Oil Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Ai 6 Are there easements on the property? /t D Site Information a. Dimensions or acreage of lot b. Is this a corner lot? A 0 c. Will the grade be changed as a result of construction Yes k No d. Public water or Private well JLl C e. Sewer or Private Septic System 5-e,o.) Value of all work to be performed (labor or materials) $ '.Oi 000.00 DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: _AA ,— Gl - _L,.,_vT DATE 9/30/20/41 SIGNATURE: .„4../ . // DATE n1/20!02-0/f FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building&Codes Principal Structure Application July 2014 U c Q 2O1' Lr n ^ 2014 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. • Malo Office 176 Doe Run Road-Manheim,PA 17545 • MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL • Permit No..,..f..% '.` ,7i...........Cert. 85561 . Cut-in Card No : Owner , ?tf.?y 0.Q..h.c..44rT Location G ......(.`i :4Q '- Installation Consisting of.,.N,iS ce-lr /,.✓/1114.(24,- : f‘ /.4. .S- ....�/...1:.c.r,t. -... • ...,L1 e...27.51. / A4? ,....., Z. .J. ..&.6).ea......4ece,v1 ..?y.... ....i Y.P...Ve� .. • Installed By.....4'/.in.2.x.(.i. El.sSe7' iS.r Lie.No. • The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- • This certificate only covers the electrical equipment and installation conditions as of date. Upon the • . introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of snaking inspections at any time, and if its rules arc violated,the Company shall have the right to revoke this certificate. Date 1,L2 -,,,,,'„ ' INSPECTOR .... cCiitenee4,utic-i-er' . .. • Mtmbcr N.F.P.A.,l.A.li.l. • TO 3Jdd 0l8Nf1N Nal b85t86L LZ Zt btOZ/E0/ZZ LOO'd ti8S 186E 817:60 ti l OZ!£OIZ L awiliale0 X8 �t1 l6.4244_ 11-)3 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/p I-.art:/ t7 am/pm Date Inspection request received: Inspector's Initials: NAME: fj ar-Y - - IT#: LOCATION: („p DATE: TYPE OF STRUCTURE: Resj pr, Comments: DID mina1P0A Yes No N/A 4" Building Number Address visible from road �,1✓( se's . Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 (O I.3 659 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant - Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Invacy/trim I doors I main entrance 36 inches (jBatl1fg Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Eve Bedroom: z / Y/ Outside every bedroom ea: Inter Connected: ' Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom fixtures Fans, if no window Plumbing Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% CO ¶ 4-_ Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required jl Okay to issue C/C or C/0[Temporary/Permanent] tf L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 Rough Plumbing / Insulation Inspection Report 1\1j-1-5I `Jr Office No. (518) 761-8256 Date Inspection re s est received: Queensbury Building & Code Enforcement Arrive: ' N A A� /pm 742 Bay Road, Queensbury, NY 12804 Inspector' nitia s: I`. NAME: •L}0 b PERMIT #: LOCATION: to < (\\p id, n INSPECT ON: (/ TYPE OF STRUCTURE: R - 'H )'-1—. Y N N/A Plumbing under slab Rough Plumbing / Nail Plates t57 Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test / Drain /Vent Air/ Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/ Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape Blower Door Test Air Sealing COMMENTS: R,--- v\ �� ��� Rough Plumbing_Insulation Inspection 02 0513 Town of Queensbury Building & Code Enforcement (i e s Office No. (518) 761-8256 Framing I Firestopping Inspection Report Inspection request received: 1� Name: fj h e r T Inspected on: /0 Location: to a tGt o,n Arrive: I •-• _ a.m.l p.m. Permit No.: / '� may / Inspector's Initials: � � 7 TYPE OF STRUCTURE: ec, P114, / Y ' N N/A COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing / Firestopping Inspection Report