2014-483 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
5Q r}>
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: P20140483 Date Issued: Friday, October 17, 2014
This is to certify that work requested to be done as shown by Permit Number P20140483
has been completed.
Tax Map Number: 523400-279-018-0001-028-000-0000
Location: 83 SUNNYSIDE EAST
Owner: ROGER BOOR
Applicant: ROGER BOOR
This structure may be occupied as a:
Septic Alteration Residential
Test Pit / Perc Test Review By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
` � 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140483 Application Number: A20140483
Tax Map No: 523400-279-018-0001-028-000-0000
Permission is hereby granted to: ROGER BOOR
For property located at: 83 SUNNYSIDE EAST
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ROGER BOOR Test Pit/Perc Test Review
83 SUNNYSIDE EAST Total Value
QUEENSBURY,NY 12804-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
SANITARY SEWER
GEORGE DRELLOS 792-7257
PO BOX 224
GLENS FALLS NY
Plans&Specifications
2014-483
Res. Septic Alteration
$200.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, October 06, 2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o •ue'. bury; 0' i :y •ctober 06,2014
SIGNED BY I rilt for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
Town of Queensbury Building & Codes Received:
Tax Map ID: /) 9. f8 -- /- 4 S
SEPTIC DISPOSAL PERMIT Permit No.: k.',-41 83
t ,
A permit must be obtained before beginni tion;, ; Permit Fee: $ Li V/ OP
Approvals:
Applicant: �/O
,q_.(7/- vJ e` Installer/Builder / /V/� Jce-e---ev-
Address: (/r� SG✓� :' -c'. - .S-4- Address / - .x 227'
62 3 cr—
G//.,1 6z/zs ,J
Phone: O Phone /`,t°" 77-,i-- 72.f-7
Owner: Location of Installation s Ser n Sick �=i/s.-
Address: 3,4-f e.
Phone �ar, p
Contact Person for Building&Code Compliance: 6e0,9,„ b r � Day Phone: 7F1-J7‘0
Residence Information:
Year Built #of Bedrooms x Gallons per bedroom =Total Daily Flow
1980 or older / x 150 = Ys-O Garbage Grinder installed? /'y
1981-1991 x 130 = Spa or Hot Tub Installed? /1"0
1992-Present x 110 =
Parcel Information:
Topography 'x Flat Rolling _Steep Slope %Slope
Soil Nature i Sand Loam Clay _Other
Groundwater At what depth?
Bedrock/Impervious Material At what depth?
Domestic Water Supply Municipal ,k Well(if well,water supply from any septic system absorption is ft.)
Percolation Test Rate-/-.3 per minute per inch(Test to be completed by a licensed professional engineer or architect)
Proposed System for New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect
(unless installed in a Planning Board approved subdivision).
Tank size /. gallon(minimum size 1,000 gallons),add 250 gallons to size of septic tank for each garbage grinder,spa or whirlpool tub
System Type: Absorption Field(with#2 stone) Total length a°0 ft. Each trench 5V f X V
Seepage Pit(S)(with#3 stone) How many? Size?
Alternative System Bed or other type?
Holding Tank System Total required capacity? Tank size? #of tanks?
NOTE: 1)Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency-see Certified Electrical form
on Town website; 2) Effective as of March 23, 2006 Septic System-As Built Plot Plan: The Building Department will no longer allow systems to be
covered until such time as an As-Built Plot Plan is received and approved by the Building Inspector. The installed system must match the septic system
layout on file. There will be no exceptions.
For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based
upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an
applicant,shall be void.
✓I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary
Sewage Disposal Ordinance.
Print Name: �/� ))/E-ag_i Date: /0 - I; . / 9
Signature: -1 � Date:
/0 6 - /G/
Town of Queensbury Building&Codes Septic Disposal Permit 518-761-8256
Town of Queensbury Building & Code Enforcement Cl i?5 - -CO / 0 — 1—L—
Office
Office No..(518) 761-8256 i 30"- lZrtioc.
1
Septic Inspection Report
Inspection request received: ii 0 11L0(-1
Name: '300 P-., Inspected on: 0 0--/L
Location: 3 S/f n/ S ' AQ- E--JA S / Arrive: N. '�� a.m.l p.m.
Permit No.: ` 0/ — 0! 3 Inspector's Initials: 1NL..%
Comments and/or diagram
Soil Type 4 /Loam/Clay
Type of V1 er: Municipal/Well Water
Waterline separation distance ft.
Well separation distance ft.
Other wells: ft.
Well Casing Length 50'+/- Y N N/A
[150'to well required if NO]
Absorption Field: Total length AZ2-D ft. t_dt -17
Length of each trench Z' ft.
Depth of trenches `p"-la"-F0,
Size of Stone l+t -2_—
Seepage Pits: Number
Size: niAc x
Stone Size:
Piping Size Type rte,•',�
Building to tank c ' L`Y�"� '
Tank to Distribution Box .��Distribution Box to Field/Pit23Opening Sealed: 7it
N
End Cap f N 1,-40247-1)Inlet/Outlet Pipes&Baffles '4
Manholes 12"or less below grade _Y (1•NL/
,[provide extension collar if Yes] _Y_
Location/Separations
Foundation to tank ft. 5 C.
Foundation to absorption _CpSfft.
Separation of Pits 1U`ti
Conforms as per Plot Plan N, N
Engineer Report and As-Built _Y
ETU Maintenance Contract provided _Y_N
Location of S -• _: ;,.y:
Front Rear bt Side Right Side Middle Front Middle Rear
S stem Use Stat;..
Approved
Partial Approved and needs to be re-inspected, please call the Building & Codes Office
Disapproved
Septic Inspection Report
I
1 .
I .
. ---- ,
1 .
. .Z5
I "7-
'c"...-
1 -
N 1
.....„,
I I
---r" ,
I -3;
-____
o1 ,s-, )• ty
? _
1
I
i\-)
i I .•... CI=LL
t ; .
I 0 i 1
1 ,
4 •
C--)
\) rEc !
L..., 1 / i. 4
1
/
./
I
,
•••••_ 1 .-
:1 . 6 -1'"1-10 PLOT,PLAN <:—.. '>4.. ..)
-,„ I HAVE SEEN OR OBSERVED AU 09,1E. k.),
VN 1 -. k.p.•
/2v) SUCH AS HOUSES, WELLS, TREES. FENCES, 1-Tit '
.. " SHOWN ON THIS DOCUMENT.I HAVE PERSONA LY - -
I MEAS"D THE DISTANCE SE ORTH HIS DIAGRA..
1 tN. /k_kvaui7L_ or __
; /.1.): SIGNATURE DATE
1 1••
' 1 / • ‘•-
i /
K\t)/
/1, 04
I
. 7 ,
i
' ' C. " 1014
1
1.__
• • , I
I '1U
I
\ .1
c )..
-.1.. .
1
ck, i
i .
i ! ---.
r
,•
i
• .
.
.
! i
I .
•
i
I
1
i
1
rr
11 NN r......------11
1
4� T i
I 0 ; . j a Z
. J I
r �
1 I
' , 6• ,
.T �tly-rIC PL.QT_PLAN C-----F
I WV!! SEEN OR OBSERVED ALL CMJECr& V,
!n ft SUCH AS HOUSES, WELLS, TREES. FENCES, :T ,, d
y, I • SHOWN ON THIS DOCUMENT.I HAVE PERSONA LY - - _
I MEAS DD THE SE ORTH N Hff IS�D.IAGRAP.
1 /r, SIGNATURE DATE
/Is\' v
i /� (()i().°13 A
j / ; LA C6 ZU + `%.
i f
2.,_ r
,Ni„, .....±;
N ----,-_, -C
1 I Cy
t
3'.'
I I Y
L
N
\ 1
N .
1 "t' `` r Z — ! `'
'' '\') ,n C ,
W iJ i
i t
_ r ------
. II
��'
I i
--
r ____
f
1 M /
.�I
i/ ...: 'cc
•
.,, \J 'J
V
�i �vi
ire � f'TI - •T PLA
I HAVE `•.EEN OR OBSERVED A OBJ CTS
I /1\\-' SUCH AS HOUSES, WELLS, TREES, '_NOES, ETC
i 1SHOWN ON THIS DOCUMENT.I HAVE I ERSON LLY i,
/ nmEDISIArHSDIAG N , <
lici
i SIGNATURE DATE G G%
V�
13,_ ,r,
,..1 .
i ;
. .
. .._______
1_
s i I
ira
y
i ,NNIIIII\1/411. ,,
,
V
V