Loading...
2014-507 TOWN OF QUEENSBURY IVO 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140507 Date Issued: Friday, November 21, 2014 This is to certify that work requested to be done as shown by Permit Number P20140507 has been completed. Location: 1415 STATE ROUTE 9 Tax Map Number: 523400-288-000-0001-053-000-0000 Owner: NORTHWAY OUTLETS, LLC Applicant: BBL CONSTRUCTION SERVICES This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve e the property ( P owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. (� TOWN OF QUEENSBURY `oto 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140507 Application Number: A20140507 Tax Map No: 523400-288-000-0001-053-000-0000 Permission is hereby granted to: BBL CONSTRUCTION SERVICES For property located at: 1415 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: NORTH WAY OUTLETS, LLC Commercial Alteration $31,850.00 2700 WESTCHESTER Ave Suite 407 Total Value $31s50.00 PURCHASE NY 10577-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications BP 2014-507 Lindt Chocolates, Suite 137 The Outlets at Lake George West Commercial Interior Alterations: Demise Wall and Bathroom Walls $75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, October 14, 2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow of Qu sbu tori c ober 14,2014 SIGNED BY Neet for the Town of Queensbury. Director of Building& Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only t! E DATE la 19 /(y Received V -. �: c �J Tax Map ID ,C Tax MAP ID ,aj-(-�3 Permit No. I �'�,'� Permit Fee wited,. ZONING Rec Fee i Site Plan# j — HISTORIC SITE _Yes _No Subdivision# II /� - "� I SUBDIVISION NAME Lot#_ J�L GL( 1 `J 2014 .0 TOWN BD. RESOLUTION 86-2O13: $650 RECREATION FEE FOR NEW OWEWNG UNITS, INCLUDING SINGLE FAMILY DWELLINGS, TOy�IV OF(,)UG EI DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR BUILDING& IDES MANUFACTURED&ppMODULAR HOMES,BUT NOT MOBILE HOMES THIS IS IN ADDITION TO THEHEPERMIT FEE. np /� CODES APPLICANT PAC_ &,gs7klt[,rpl4 &fprnce$. OWNER 5OI& T /.EAL-n( `ptP - . - ADDRESS 3O (AJASHn+AtON Ave en ADDRESS aa:CD Wesreitiesrae .4e- 0 `� Q.. Shire L o7 `AA,,eassse, NY :657. m PHONE/E-MAIL (518r)1152 - taco PHONE/E-MAIL (5111) 0253 -eta r W Q� T 2 O cc cc CONTRACTOR '�t AL apaSTt4AC:Tfa) &It)'CMS COST OF CONSTRUCTION(ESTIMATED): $ JI)ISO a W ADDRESS: 3 Waw,lJ470AJ Ave ST, BUILDING ADDRESS: Igt5j et. 1 4 a-Ns6f44y m coi S4atl5 137 ea "' M v g PHONE/E-MAIL (99) '�Sa- UaCJO 1 �,,,,,. '" r . N co CONTACT PERSON FOR BUILDING 8 CODES COMPLIANCE: Jbru,4y W i+tre•-nnµ RHONE(.518')94/-9337 u• o Z O 8 `0 o~ w TYPE OF CONSTRUCTION a1 Z m 2 ce O• Ca¢ m Check all that apply Please indicate measurements as required below u o O m mQ New Addition Alteration 1„floor sq.ft 2n°floor sq ft Total sq.ft Height .0 m U Single Family o o p 3 W Two-Family J O Multi-Family J m F (#of units ) Townhouse Business Office Retail-Mercantile ✓ 117'f O Pr (,7,0 (t4 t LZMtsfK 4 Qty ,w yaws Factory-Industrial Attached Garage (#of ) Other 1 Tovm of Queensbury Building&Codes Principal Structure Application July 2014 1, AdE a, " 14,5 Sok, 137 4öi?et 41-- 0 �% ° Cell' C D . , /LK l ROk ? If commercial or industrial indicate name of business Proposed use of building or addition Source of heat(circle one) Gas Oil Propane Solar Other Fireplace: complete a separate application for Fuel Burning Appliances& Chimneys Are there structures not shown on plot plan? Are there easements on the property? Site Information a. Dimensions or acreage of lot b. Is this a corner lot? / c. Will the grade be changed as a result of construction _Yes ✓ No d. Public water or Private well e. Sewer or Private Septic System Value of all work to be performed(labor or matenals) $ 311$'Xi DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances,and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: W(•FI • 'DATE /Obi hie -_.,, SIGNATURE: 4. ' 'ATE 10/alt I y r • FOR OFFICE USE ONLY Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions 2 Town of Queensbury Building 8 Codes Principal Structure Application July 2014 Town of Queensbury Building&Code Enforcement Office No.(518)761-8256 Commercial Final Inspection Report Inspection request received:L///' 11!-/ Name: �, Inspected on: /1/21�y Location: Arrive: t k a.m./p.m. Permit No.: / 537 /V—Le Inspector's Initials: COMMENTS Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish I Grade Complete 6"in 10'or Equivalent Intenor 1 Exterior Guardrails 42 inch Platform/Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch—38 inch I Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq ft All Doors 36 inch w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy I Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%> 1000 sq ft. /.Hour Corridor Doors&Closers Firewalls I Fire Separation, 2 Hour,3 Hour Complete I Fire Dampers I Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage I Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space / Final Electrical/Flex Gas Piping Bonded V Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access All Sides by 20'1 Dnvable Surface 20'wide Special Inspections/Engineer or Architect Approval Okay To Issue Temporary or Permanent CIO ✓ Okay To Issue CIC Commercial Final Inspection_11 27 12 Town of Queensbury Building &Code Enforcement Office No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: Ay(41/ Inspected on: %/5lif Location: Arrive: 3;3 I) Permit No.: 4-47 S07 )/y_ 20 7 a.m.l p.m. ` Inspector's Initials: `�/� COMMENTS Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete d/ �{/ /� Exterior Finish/Grade Complete 6"in 10'or Equivalent /Fi°�'d' " �� Interior/Exterior Guardrails 42 inch Platform/Decks (AAA Interior/Exterior Balusters 4 inch Spacing Platform/Decks V Stair Handrail 34 inch—38 inch/Step Risers 7'/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch w/Lever Handles/Panic Hardware, if required1.7 Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap I Water Temperature 110 Degrees Maximum 6 Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors > 10%>1000 sq ft. %Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour,3 Hour Complete/Fire Dampers/Fire Doors ✓ j7 _/ tab-o ll.t7'c v Ceiling Fire Stopping,3,000 sq ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors VIT Handicapped Bath/Parking Lot Signage ✓ j b f/ j L4 if Public Toilet Room Handicapped Accessible v� Handicapped Service Counters, 34 inch, Checkout 36 inch V Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required /CL/ Final Survey,New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/Drivable Surface 20'wide Special Inspections/Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O Okay To Issue C/C Commercial Final Inspection_11 27 12 Town of Queensbury Building&Code Enforcement W� t' 3 Office No. (518)761-8256 Commercial Final Inspection Report Inspection request received: Name: trlcL-' Inspected on: 7/6 Location: /CH f Arrive: a.m./p.m. Permit No.: ! 'y-50) Inspector's Initials: 121 COMMENTS Y N NA o Chimney/"B"Vent I Direct Vent Location 776-31 o-'9r5)3 Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 inch Platform/Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch-38 inch/Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft All Doors 36 inch w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve, Heat Trap/Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 ''4 doors >10%> 1000 sq.ft. '/ Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers I Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp!Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey,New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 201/Drivable Surface 20'wide Special Inspections/Engineer or Architect Approval Okay To Issue Temporary or Permanent C/O1/7 Okay To Issue C/C Commercial Final Inspechon_11 27 12 Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 f c9 _ Framing / Firestopping Inspection Report Inspection request received: bt(ilia()i 4- //-- Name: f_i rc4 { I'J,`o�a c_o1e137 Inspected on: (f (a.0 ft( Location: kifI c 34rie 12k 9 Arrive: &C a.m.lp.m. Permit No.: 6P 2.0/4- SD? Inspector's Initials: TYPE OF STRUCTURE: COM!C 1t A-Lt jV/C_ l u 7 N NIA Framin Ce.k..4 +�rp � � COMMENTS: is Access 22"x 30"miniry♦rA Jack Studs/Headers ((((/��� 770 ' 34- 95/ 3 Truss Specification Provided �01 �� Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/3(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour C L� / Firestopping Ss/ a' �`t1_J /4_ bre .) eett9i- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%:inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing /Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report tJl Office No. (518) 761-8256 Date Ins'ection reel d: Pa ` Queensbury Building & Code Enforcement Arrive: ` 11-1 �` 742 Bay Road, Queensbury, NY 12804 Inspector's Initial.s NAME: kf v d 4 PERMIT#: {-i-567 LOCATION: - lx/15 INSPECT 01 . —/k/ TYPE OF STRUCTURE: Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place Lob,),1JE.aN�5 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum @ tO�� Cleanout every 100 feet/change of direction \t�lco` Pressure Test Drain /Vent A 5 P. 5 P.S.I..I. for 10 ft. above highest connection for 15 minutes Pressure Test Supply Piping V// 50 P.S.I. for for 15 minutes Insulation / Residential Check/ Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumhing_Insulation Inspection_02 0513 ues gam Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins cti n uest received: Queensbury Building & Code Enforcement Arrive: '4 am/pm 742 Bay Road, Queensbury, NY 12804 � Inspector's ni I s: { NAME: L6-h�ej( vt cl4 /3!/ PERMIT#: y" ►,- 3-$ '- LOCATION: ) /6 - 1)7 INSPECT ON: /b r3.f'-P9 TYPE OF STRUCTURE: O�e'r« 6) g 19 +Z 91/.93 Y N N/A Plumbing under slab Rough Plumbing /Nail Plates / WECCLZAS Plumbing Vent/Vents in Place p eikc 11/2 inch minimum Drain Size I �ur�bt Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air /Head 50 P.S.I. for for 15 minutes Insulation /Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumhing_Insulation Inspection_02 0513 -7a Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Insctpg ion request received: /9//i-/,l/1/ Queensbury Building & Code Enforcement Arrive: ' J am/pm 7/ 7 742 Bay Road, Queensbury, NY 12804 (111- Inspector's Initials:7 ✓ f NAME: Li,. a ( c rir (1 e� PERMIT#: I v�✓CG�-// �/y T LOCATION: I t(i 5 57R0INSPECT ON: ___227t TYPE OF STRUCTURE: r / SA 1-72 Y N N/A Plumbing under slab -*Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Z A,Water Supply Piping Air/Head //,e.- lK,rj /0% 50 P.S.I. for for 15 minutes U,-P ffi tid Insulation /Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumhing_Insulation Inspection_02 0513 Town of Queensbury Building & Code Enforcement ( cc2_b. Office No. (518)761-8256 Framing I Firestopping Inspection Report Inspection request received: // Name: L Crn.(U3' Inspected on: /'�!�Y/,7 Location: 19kJ--) 'S � � Arrive: //<F//////ip a.m.Ip.m. Permit No.: I<I"Sa t/i Inspector's Initials: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided ALBracing I Bridging pl1�Gk d ���'L Joist hangers D Jack Posts/Main Beams 0� 1+"- A.hn Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 ''A(w) 16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water s 24 inches from wall S j / Fire separatio , 3 hourt ruc Fire wall 2, 3, hour 674a t Oa Firestopping / Penetration sealed 74/ AM.-. S/vL /had-""L 4 60a 16 inch insulation in cavity min. ` r" Garage Fire Separation -7 `� �� L�� House side 1/2 inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/ Firestopping Inspection Report