2014-548 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20140548 Date Issued: Wednesday, December 17, 2014
This is to certify that work requested to be done as shown by Permit Number P20140548
has been completed.
Location: 1 MANOR Dr
Tax Map Number: 523400-301-008-0001-024-000-0000
Owner: MAPLE WOOD, LLC
Applicant: MAPLE WOOD, LLC
This structure may be occupied as a:
Residential Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board
Director of Building&Code •'orce 4.nt
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
Vera742Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140548 Application Number: A20140548
Tax Map No: 523400-301-008-0001-024-000-0000
Permission is hereby granted to: MAPLE WOOD. LLC
For property located at: 1 MANOR Dr
in the Town of Queensbury, to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: MAPLE WOOD, LLC Residential Alteration $8,400.00
6 E MANOR Dr Total Value $8,400.00
QUEENSBURY,NY 12804-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2014-548 1C Manor Drive
Res. Alterations 72 sq.ft. (smoke damage)
$60.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,October 30,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of Qu sbu /f Ts? S ctober 30,2014
/d G
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
PRINCIPAL STRUCTURE APPLICATION Office Use Only
DATE /O sj94/OVVY Received
Tax Map ID
TAX MAP ID Y
f--'
�� Permit No. e' - t.J
Permit Fee 41-
V
N Rec Fee
ZONING .3\�=;
Site Plan#
HISTORIC SITE Yes )c No Subdivision #
SUBDIVISION NAME Lot#
TOWN BD.RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS,INCLUDING SINGLE FAMILY DWELLINGS,DUPLEXES
OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR MANUFACTURED &
MODULAR HOMES, BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE.
AftJ / G/
APPLICANT �L. OWNER
ADDRESS — 41)gi)®r O r ADDRESS �'f � LG �� P2)1-1-
ctIeca,flour-{/
divid l 2 L) ( Al 1
PHONE/E-MAIL PHONE/E-MAIL ! �
CONTRACTOR _ cm • COST OF CONSTRUCTION(ESTIMATED): $ UJ
ADDRESS: ? � c BUILDING ADDRESS: / C- 4.
s&lrbt /1/1
PHONE/E-MAIL-6-4-30 7 `'V, ?5-
CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: )€ r( 1 PHONE (";'1(?--3,61) 'y S
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
New Addition Alteration 1s`floor sq. ft. 2nd floor sq.ft. Total sq. ft. Height
Single Family
Two-Family
Multi-Family S;�
(# of units I/ )Atv'� 0,2 ���•
Townhouse
Business Office
Retail - Mercantile
Factory- Industrial
Attached Garage
(# of
Other
1
Town of Queensbury Building&Codes Principal Structure Application July 2014
If commercial or industrial indicate name of business
Proposed use of building or addition
Source of heat (circle one) Gas Oil Propane Solar Other
Fireplace: complete a separate application for Fuel Burning Appliances & /‘_ 4Chimneys
Are there structures not shown on plot plan? /7/(/
Are there easements on the property?
Site Information di"? - Pcivil 44/1 (Ks,
a. Dimensions or acreage of lot
b. Is this a corner lot?
c. Will the grade be changed as a result of construction Yes No
d. Public water or Private well
e. Sewer or Private Septic System pr ;r
Value of all work to be performed (labor or materials) $
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department
approval.
3. I certify that the application, plans and supporting materials are a true and complete statement/ description of
the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building
laws and ordinances, and in conformance with local zoning regulations.
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy.
5. 1 also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above: PRINT NAME: : r . in DATE /6 —015_ /1
SIGNATURE: M ,_ DATE/0_J --
FOR OFFICE USE ONLY
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
2
Town of Queensbury Building&Codes Principal Structure Application July 2014
ues9I/
Multiple Dwelling, Hotel, Motel, Apartment
Final Inspection Report
Office No.: (518)761-8256 Date Inspection request received: .�
Queensbury Building&Code Enforcement Arrive: am/pm Depa . ' \ -:'�'"'. ''
742 Bay Road,Queensbury, NY 12804 Inspector's Initials.
NAME: Y Q -(> (30t PERMIT#: S.-q8
LOCATION: t C Gtnd r D r . DATE: I ok- /L2-4 t"/
Y N NA COMMENTS:
Chimney Height / "B" Vent / Direct Vent Location h
Plumb Vent Thru Roof Minimum 6" f LJ�'�' 3 f7 /'"&/5
Roof Complete 0
Exterior Finish Complete / Finish Grade 6" In 10' Drop
Interior/Exterior Railings 34 Into 38 in. / 36" Landing,
Decks, Porches
Exterior Handrails, Balconies, Landing 30" Or More
Interior Handrails Balconies / Landing 30" Or More
Interior Handrails Stairs 1 or More Risers
Guardrails 42", Ballisters 4" Minimum Spacing
Vestibules For Exit Doors > 3000 sq. ft
Doors 36" / Lever Handles
Headroom 6' 8" on Stairs
Bathroom / Kitchen Watertight
Smoke Detectors: Every level, Every bedroom �7
Outside every bedroom, Interconnected Battery \ �--
Backup
Carbon Monoxide Alarm - lowest sleeping level V
Bathroom Fans / Plumbing Fixtures Complete I
Foundation Insulation --1>A441\y^
Fire Separation, 3/4, 1, 2 hr.
Fire Walls 1, 2, 3 Hour / Fire Door 3/4, 1 1/2, 2 Hour
Handicapped Accessibility / Handicapped
Parking/Signage
Gas Log In Sealed or Glass Enclosure
Gas Valve Shut-Off Exposed / Regulator 18" Above
Grade
Gas Furnace Shut-Off Within 30 ff. or Within Line Site
Oil Furnace Shut-Off at Entrance to Furnace Area
Furnace / Hot Water Heater Operating / Fresh Air Intake
Low Water Shut-Off for Boiler
Relief Valve, Heat Trap /Water temp 110 Degrees Max.
Garage Fireproofing Complete, Penetration Sealed
Furnace In Separate Room / Protected (In Garage)
Light Ventilation per Room /Safety Glazing
Attic Access 30" x 20" x 30" (H) / Crawl Space 18" x 24"
Final Electrical
Site Plan/Variance Required
Final Survey Plot Plan / Flood Plain Certification, if Req.
As-built Septic System Layout Required
Building /Apartment Number on Building or Driveway
Build Access All Sides by 20', Driveable Surface 20" Wide •
Okay To Issue Temp C/O or Permanent CO (circle one)
Okay To Issue C/C
L:\B&C APPLICATIONS-OFFICE USE\MULTIPLE DWELLING.doc
ca'
Rough Plumbing / Insulation Inspection Report rs� u ~
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: I , r' am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: N\ pkg 10 nock PERMIT#: M'S-cirg
LOCATION: d I\66—P cr Dr INSPECT ON: /F17 —AY
TYPE OF STRUCTURE: ps
Y N N/A
Plumbing under slab
Rough Plumbing / Nail Plates
Plumbing Vent /Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain /Vent
Air / Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check / Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape
Blower Door Test
Air Sealing
COMMENTS_
Rough Plumbing_Insulation Inspection 02 05 13