2014-620 TOWN OF QUEENSBURY
WiT4TO
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20140620 Date Issued: Friday, February 20, 2015
This is to certify that work requested to be done as shown by Permit Number P20140620
has been completed.
Location: 578 AVIATION Rd HI #1
Tax Map Number: 523400-302-005-0001-092-011-0000
Owner: AVIATION MALL NEWCO LLC
Applicant: PRIME COMMUNICATIONS OF NY, LLC
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property
owner of the responsibility for compliance with Site Plan, Variance, or //
P tY P
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
MA
` O 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140620 Application Number: A20140620
Tax Map No: 523400-302-005-0001-092-011-0000
Permission is hereby granted to: PRIME COMMUNICATIONS OF NY.LLC
For property located at: 578 AVIATION Rd HI #1 .
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: AVIATION MALL NEWCO LLC
Commercial Alteration $152,000.00
4 CLINTON Sq Total Value
SYRACUSE,NY 13202-0000 $152,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2014-620
Comm. Alterations 1,152 sq.ft.
' $233.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,December 23,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o Quee
j /�'ues r . ,;7 e • II ber 23,2014
/rues 4.
SIGNED BY Z for the Town of Queensbury.
Director of Building&Code Enforcement
PRINCIPAL STRUCTURE APPLICATION Office Use Only
DATE I211-I1c/
Received ZOti
Tax Ma l 0,,
bi
TAX MAP ID Permit 4J / q -L a o
Permit Fee ,R 3 (, 0
ZONING It-)npr! SRec Fee
/ Site Plan#
HISTORIC SITE Yes 1/ No Subdivision#
SUBDIVISION NAME Lot#
TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS, INCLUDING SINGLE FAMILY DWELLINGS,
DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR
MANUFACTURED&MODULAR HOMES, BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE.
APPLICANT —Prim E CO-71c ICA-1-1N, nF" / LLC OWNER AV I rrno NEGOC I c C
ADDRESS 12,5•70 I�Pe —?o A7 SLI4 r' /0 c, ADDRESS 'q C �
1,iv ,,r S0 .
306 A-K--t AN 'A -I 7 q--1 8 c,ck.SP Ni /..52.07
PHONE/E-MAIL PHONE/E-MAIL CSI$) 7 S 3 - 8 s' 8
CONTRACTOR , 11-1c•i Co"! f n ,c.-.r o,./ Co COST OF CONSTRUCTION(ESTIMATED): $ /32 cor
ADDRESS: f-ow Ip y BUILDING ADDRESS: 5 7? Av i r►o ry )Zo 41
\k)r- -,try 2-8 39
PHONE/E-MAIL (51 s ) -7 -
CONTACT PERSON FOR BUILDING& CODES COMPLIANCE: , lr-,hw PHONE 793 -8S8-
TYPE
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
New Addition Alteration 1st floor sq. ft. 2nd floor sq.ft. Total sq. ft. Height
Single Family
Two-Family
Multi-Family
(# of units )
Townhouse
Business Office
Retail - Mercantile I I c:
Factory- Industrial
Attached Garage
(# of )
Other
1
Town of Queensbury Building&Codes Principal Structure Application July 2014
If commercial or industrial indicate name of business
Proposed use of building or addition
Source of heat (circle one) Gas Oil Propane Solar Other
Fireplace: complete a separate application for Fuel Burning Appliances &
Chimneys
Are there structures not shown on plot plan?
Are there easements on the property?
Site Information
a. Dimensions or acreage of lot
b. Is this a corner lot?
c. Will the grade be changed as a result of construction Yes No
d. Public water or Private well
e. Sewer or Private Septic System
Value of all work to be performed (labor or materials) $
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement / description of
the work proposed, that all work will be performed in accordance with the NY State Building Codes, local
building laws and ordinances, and in conformance with local zoning regulations.
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above: PRINT NAME: �a,._i,c Lt. C lk,e tia---x_uor- DATE , i 15 I )l/
SIGNATURE: `�0ti111lQ11�"Zit t DATE i2 /.•r I iy
FOR OFFICE USE ONLY
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
2
Town of Queensbury Building&Codes Principal Structure Application July 2014
Inspection Form
Town of Queensbury Fire Marshal o Periodic Inspection Date: !j 1 .t.)I'sTime: 4PM
742 Bay Road,Queensbury NY 12804 o Re-Inspection
518 761 8206/518 761 8205 ,'CO Inspection Permit#: . /2/V&e?
Fire Marshals Representative
7 Palmer Business Name: 4 I > f //4 S L Ln+&aci.J
ct
Location: x-78 d,4,41 R s2
GK Stillman Contact: i" h%
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 / NOTES
_ Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Sign:Normal FC 1011 &FC1029 �/
Sign:backup FC 1011.5.3&FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11 ..- :.„
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906 _.-------
Inspection of extinguisher FC 906 ,..-----
__.-
EVAC
�EVAC Plan FC 404.2
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8 .-----.
Exterior FC 1006.3 F---"'
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1 --- --
Combustibles in Equipment Rooms FC315.2.3 / •
F.D.Siqnage- FC 510
No Smoking Signs FC 310.3 .....----
Storage FC 315.2
Compressed Gas FC 3003 0di
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24" //
EVAC SIGNS IN Rooms FC 404.6(R1 &R2) _
Fuel Pump Warning Signs FC2205.6 ,/ •
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMA TEL Y
Vacant Buildings FC 311 .'
Emergency Disconnect FC 2203.2 �/ 21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual /
FIRE ALARM Annual oX DATE: OK NC
HVAC Shutdown /
Sprinkler System Annual A115-- );
Sprinkler FDC
Kitchen Suppression Semi Annual
Fuel Island Suppression Semi Annual ,
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506 1
Operating Permit, if required will be issued after
Completion of Inspection
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection request received: a— 13
Queensbury Building &Code Enforcement Arrive: am/png Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: 1 PERMIT#: /4- " 7)
LOCATION: 1✓1A,{ DATE:
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish I Grade Complete 6" in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/ Decks
Stair Handrail 34 in. -38 in. /Step Risers 7"/Treads 11"
Vestibules For Exit doors> 3000 sq. ft.
All Doors 36 in.wlLever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44" (1)/Canopy or Equiv.
Gas Valve Shut-off Exposed &Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occ pancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 '/s doors
> 10% > 1000 sq. ft.
3/Hour Corridor Doors&Closers
Firewalls I Fire Separation, 2 Hour, 3 Hour Complete I Fire
Dampers/ Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/ Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 38"
Handicapped Ramp/Handrails Continuous/12 in. Beyond [Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical l Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification, if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access All Sid -►�Drfvete Surface 20'wide
Okay To Issue Temp. Permanent C/ i. c/✓ _
Okay To Issue C/C
L:\Building&Codes Forms'Building&CodeslInspection Forms\Commercial Final Inspection Report.doc Revised January 7,2008
:),3u )0: ‘,1
I _-
Commercial Final Inspection Report T J, i
Office No.: (518) 761-8256 Date Inspection request received: ' 14;) 6 i al_ &J
Queensbury Building &Code Enforcement Arrive: 5 '3- am/ m`,i Depa . am/pin
ireAM
742 Bay Road, Queensbu , NY 12804 Inspector's Initials:'P/V
=l�—1 low. A ) i - - .
NAME: s r�S-r PERMIT#: `f
LOCATION: I r DATE: Pia ,
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete of
Exterior Finish/Grade Complete 6" in 10'or Equivalenti� r v i,
Interior I Exterior Guardrails 42 in. Platform!Decks ( .;-�
Interior I Exterior Ballisters 4 in. Spacing Platform/Decks I ��t,�c c--/-6itki✓r°
Stair Handrail 34 in.—38 in. /Step Risers 7"I Treads 11" //
Vestibules For Exit doors> 3000 sq. ft. ,/,,,_ (2,1-&)13
All Doors 36 in. w/L.ever Handles!Panic Hardware, if required I
Exits At Grade Or Platform 36(w)x 44" (I)/Canopy or Equiv.
Gas Valve Shut-off Exposed &Regulator(18")Above Grade �� �
Floor Bathroom Watertight/Other Floors Okay /
Relief Valve, Heat Trap I Water Temp. 110 Degrees MaximumI/ R
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion /�
Low Water Shut Off For Boilers �G
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 Y2 doors L �
> 10°!° > 1000sq. ft. �' 6
'A Hour Corridor Doors &Closers
Firewalls I Fire Separation, 2 Hour, 3 Hour Complete I Fire6
0- eiLlAt
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame g
Attic Access 30"x 20" x 30"(h), Crawl Space Access 18" x 24" V Vic.
Smoke Vents Or Fan, if required 1' \
•
Elevator Operation and Signage/Shaft Sealed ��
HandicappedBathroom Grab Bars I Sinks I Toilets `�
Handicaped Bath/ Parking Lot Signage lr
Public Toilet Room Handicapped Accessible f v�
Handicapped Service Counters, 34 in., Checkout 36" ✓ tr•
Handicapped Ramp I Handrails Continuous/12 in. Beyond [Both
sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required _,
Final Survey, New Structure I Flood Plain certification,if req.
As-built Septic System Layout Required or On File
_Building Number or Tenant Address on Building or Driveway 4'
Water Fountain or Cooler
Building Access All Sides 8'7 Drivable Surface 20'wide /
Okay To Issue Temp. Permanent C/03- ✓ //
Okay To Issue C/C ______ rirr.)4 / ,K 44411.15.5,0
L:\Building&Codes Forms1Building&Codes1Inspection Forms\Commercial Final Inspection Report.doc Revised January 7,2008
IVC • 7 -
--Y\v--0•1 .c_AK5 ---01. " c--c`-\
.• .
. . i. •
• .•
COMMONWEAIXII ELECTRICAL INSPECTION SERVICE,INC.
• .
•• •
.• .
Main Office 17b Doe Run Road-Manheim,PA 17545 •
•
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL • • . •
.•
•
. .
•
, .
Permit No. ./.."1,-, 2..c? Cert. 85648 Cut-in Card No ..
•
•
Owner .14.7 C--7- :
•
•
Location 6:I.& A.1.1.4,-(47.:ZsW...4:47.0 c3...vc. r.o.,i7.p..e..../ • .:
Installation Consisting of....A. .n.c..c,KIV:•.'a.".7... ..; rg,LI i2ic-cs,.. ............ 3.i...07.15, •
• •
•
. .
•
/ tiFf.17:/ .0 ru- : . .•
•
. .
•
•
. . .
. •
Installed By /20 4.4 r0 Cc,(WY.-- Lic.No ••
,
The conditions following governed the issuance of this certificate,and any certiticate previously issued is .
cancelled:-
This certificate only covers. the electrical equipment and installation conditions as of date. Upon the .
introduction of additituntl equipment or alterations,application shall he promptly made for inspection.
Inspectors of' this Company shall have the privilege of making inspections,at any time, and if its
rules are violated, the Company shall have the right to revoke this certificate. . :. .
••
•
Date 2-%./.0 1.1..1 I N SP ECTO R...4)/,11/7,444,-e-14---"
•
Member N.F.P.A.,1.A.E.I. •• , •
Z0 39Vd o1an4 NO t;i8186L ZS:G T STOZ/SZ/ZO
ZOO'd V8S 1.86L l VE 1. S l OM MO awutalea xs
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256
Framing I Firestopping Inspection Report
Inspection request received:
Name: I T— Inspected on: • _di
Location: PO 1 X11 1 O(� '�`�Ptlj Arrive: i' a. p.m
Permit No.: 11—k 1 — Z_( Inspector's Initials: ,
TYPE OF STRUCTURE: iopr
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs I Headers
Truss Specification Provided
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
/Ice and water shield 24 inches from wall
f Fire separation 1,2,3 hour
{/7/
JFFire wall 2.,3,4 hour
irestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/ Firestopping Inspection Report
Town of Queensbury Building & Code Enforcement "� l_
Office No. (518) 761-8256
Framing / Firestopping Inspection Report
Inspection request r ceive : at /
Name: Tl�� 47' 4"l Inspected on: - a & a
Location: 5''7 1,4,1'‘a46--/1444 Arrive: ►D a.m.1 p.m.
Permit No.: 024014—(e?- d Inspector's Initials: .
TYPE OF STRUCTURE: c0 I,:C j/_ , /'
1C�2
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs I Headers
Truss Specification Provided b4//1/0/)Bracing I Bridging
Joist hangers
Jack Posts I Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes 1 Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
,
Fire separation 1,2,3 hour �j cviDJ
Fire v* 3.4 hour `A. / -
Firestopping (..1471—r
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space I Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required 1 \
t
Framing / Firestopping Inspection Report : � �
Town of Queensbury Building & Code Enforcement (76,5-er-Office No. (518) 761-8256 . 4 3�oiry.
p/z_
Framing / Firestopping Inspection Report 1—3
Inspection request received: !
Name: Inspected on: fid' S / eate4,Z
Location: 5140C-1-40-. /1,/6(( Arrive: ' s �.l .m.
Permit No.: 1 ,,,/aagar
Inspector's Initials:
TYPE OF STRUCTURE: (_‘...))\A-( A--Cr
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"minimum 47/4 (Lc kc J
Jack Studs/Headers
Truss Specification Provided
Bracing/Bridging
Joistk hangPosts/ _7 q -o 3 z
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire all 2.3 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side IA inch or 5/8 inch Type X
Garage side 5/8 inch Type X \ -` (� j `P
Ceiling/wall `�
Windows Habitable Space/Bedrooms
24 in. H
( ) - \ L �L_
20 in.(W)
5.7 sf above/below grade '�
5.0 sf grade `1' ' , ��J 1 L
Design Professional Sign off,if required P C �� �w tet— u\A[
r
Framing !Firestopping Inspection Report / I.
Rough Plumbing / Insulation Inspection Re ort mom`
Office No. (518) 761-8256 Date Ins, •ctio pe1ii : •d:
Queensbury Building & Code Enforcement Arrive: `� a �
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: , ,
NAME: 1`JI A' 1 PERMIT#:
LOCATION: r7 2 / A_ ( R( INSPECT ON: i S
TYPE OF STRUCTURE: 4
Y N N/A
17-C
le
Plumbing ander slab ��
Rough Plumbing / Nail Plates ‘
/
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain /Vent
Air / Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test Y
Water Supply Piping
Air / Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check/ Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door /Window Sealed (No Insulation)
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection_02 05 13
Town of Queensbury Building & Code Enforcement on D
Office No. (518) 761-8256
Framing I Firestopping Inspection Report
Inspection request received:
Name: p k T Inspected on: —5
Location: 5 ) ? Pai Arrive: •MME . p.m.
Permit No.: / '/-Lo 32D Inspector's Initials: Mir
TYPE OF STRUCTURE: L!J
Y N NIA COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs 1 Headers
Truss Specification Provided
Bracing I Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above I below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing/ Firestopping Inspection Report
Lococi 4)1
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: -' am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto s InitialsY '(
NAME: s--1 4 _ 1„ • eil1i A PERMIT#:
LOCATION: . . ` -✓l7tct3a c Rd INSPECT ON:
TYPE OF STRUCTURE:
N N/A
Plumbing under slab
^
110
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check/ Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door / Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumbing_Insulation Inspection 02 05 13