2014-638
,•_41111A. TOWN OF QUEENSBURY woo742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20140638 Date Issued: Friday, June 26, 2015 This is to certify that work requested to be done as shown by Permit Number P20140638 has been completed. Location: 45 MELDON Cir Tax Map Number: 523400-289-020-0001-048-000-0000 Owner: MICHAELS GROUP Applicant: MICHAELS GROUP This structure may be occupied as a: Fireplace By Order of Town Board Garage Attached TOWN OF QUEENSBURY Townhouse Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or APIAefiD other issues and conditions as a result of approvals by the Planning Board Dire'llirrouil i g&Code Enforcement • or Zoning Board of Appeals. • TOWN OF QUEENSBURY S` � � 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20140638 Application Number: A20140638 Tax Map No: 523400-289-020-0001-048-000-0000 Permission is hereby granted to: MICHAELS GROUP For property located at: 45 MELDON Cir in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAELS GROUP Fireplace SUITE 1 Garage Attached 10 BLACKSMITH Dr Townhouse $260,000.00 MALTA,NY 12020 Total Value $260,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2014-638 Townhouse 1,760 sq.ft. Garage 444 sq.ft.; 1 fireplace $418.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,December 30,2015 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury beforeorthe expiration date.) Dated at the Townv6t�u/nsb T t ",December 30,2014 SIGNED BY C leil f for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE ONLY TAX MAP NO. ' Rep .— ._ (/ g PERMIT NO. /9-te 3 g FEES: PERMITi g40 RECREATION ENGINEERING DEC 1 G 2014 (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: -The- Mlc--►i•�t-S C-Igol„P OWNER: ADDRESS: Io BLAC1LS1A1114 UIZ MALTA M-t IZ0Z0 ADDRESS: " PHONE NOS. 51e-8`19 - Co- 1I PHONE NOS. " CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: T• C.p.sc-ti o PHONE: b''a1 -314 4- LOCATION OF PROPERTY: A SUBDIVISION NAME: C_Ca SSIi LI S. PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR O �J o PROJECT p Q o O I <n " w W Ott. OL. W _ d= 3 o H u. i 2 O�Z O i CLL O ce W SINGLE FAMILY TWO-FAMILY MULTI-FAMILY(NO. ) TOWNHOUSE ( 1,-u7141 , Ao-�r V^1 (co Z-,1 BUSINESS OFFICE RETAIL- MERCANTILE • FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,03) 444 i OTHER Town of Queensbury • Community Development Office ■ 742 Bay Road, Queensbury, IVY 12804 IF COMMERCIAL OR INDUSTRIAL–NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 2 C- C' (r) c' — FUEL TYPE: G A'S HEAT TYPE? H A *HOW MANY FIREPLACE(S) AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: SIr•Ic,Le Pa't\`r 17-.es>oe3v4..e=. ('lcu+N Nt c.c ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? *Please complete a separate Application for"Fuel Burning Appliances& Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to th z4bove. Signed l` / Director of Building & Codes: 761-8256 (for questions QUESTIONS? CALL 761-8256 OR EMAIL regarding Building Permits, construction codes or septic codes a(�queensbury.net systems) VISIT OUR WEBSITE FOR MORE INFORMATION Zoning Administrator: 761-8218 (for questions regarding www•queensbury.net required permits, the permit process, application requirements or to schedule an appointment) This application / proposed action described Permission is hereby granted to the above herein is found to be in accordance with the Applicant to erect or alter the building described zoning Laws of the Town of Queensbury. herein in accordance with said Application: ZONING APPROVAL DATE BUILDING & CODES APPROVAL DATE aTown of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 Fire Marshal's Office 3 Town of Queensbury • 742 Bay Road • Queensbury, New York •12804 Date. S tamp Michael J. Palmer, Fire Marshal• Gan.,Stillman, Deputy Fire Marshal APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building & Codes Office for the issuance of a Building & Use Permit pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED. OWNER: TI-i� 1Gl-eA-�,S `C��S�U? "LLC INSTALLER/BUILDER: ADDRESS: 10 c-AC-I�.smcriA l�0-11 m.-,wY 1Zc ADDRESS: I-lbt7 A•LJA , PHONE NOS. S‘`a•eitGI •Ion I I �+ PHONE NOS. S18. 8b9. glpC)o LOCATION OF PROPERTY: 45 Mc-�,�t�1 Gtzu� SUBDIVISION NAME: 1-lilt..A -1D LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: T, L.c=C.Dr=C10 PHONE:171$•S51.3W 4- v ✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL INFORMATION STOVE FIREPLACE INSERT 7C FIREPLACE, FACTORY BUILT* FIREPLACE, MASONRY FURNACE (GARAGE ONLY) *IF FACTORY BUILT, PLEASE PROVIDE: MANUFACTURER NAME: Hes.7- h1.- CIS MODEL NO. DY 3-7 -SCSI LISTED BY: NUMBER: QUESTIONS ? CALL 761-8205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: firemarshalAqueensbury.net MASONRY** CHECK ONE ✓ VISIT OUR WEBSITE TILE STEEL SIZE IN FOR MORE INFORMATION INCHES www.queensbury.net FLUE CHECK ONE ✓ DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY WALL LINER CHIMNEY MATERIAL CHECK ONE ✓ **IF NON-MASONRY, PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION & BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. Town of Queensbury l�„! 3 e Michael F. Travis Highway f Highway Superintendent g Y Home (518) 798-0413 Department 742 Bay Road—Queensbury,NY 12804 Thomas R. Van Ness Office Phone: (518)761-8211 Deputy Highway Superintendent Fax: (518) 745-4466 Home (518) 745-0929 DRIVEWAY PERMIT DATE: 1218) 1 (- APPLICANT NAME: iTke MtcA- (ELS C..IRc , LSC TELEPHONE NO.: 5153 •c,a,°\9 . (0311 ADDRESS TO BE INSPECTED: 45 M�—TaN C Arz_ck RETURN ADDRESS: Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( )12" ( )15" ( )18" ( )24" ( )36" Preliminary inspection completed by: Date: Approval by Highway Supt: Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Michael F. Travis, Highway Superintendent Thomas R Van Ness, Deputy Highway Superintendent RA Queensbury Building & Code Enforcement - Residential Final Inspection 2P`v`1 � , -, Office No. (518) 761-8256 Arrive: am/pm De art: L. -3 rn/pm Date Inspection request received: 7(2'3\ i5 Inspector's Initials: t NAME: Mla-NA.6S 61YMp PERMIT#: 14 - h LOCATION: 15 IVke_Acw,q DATE: b l'.2(0 12-CLA.5 TYPE OF STRUCTURE: .410W v-\\no ,-v Comments: Yes, No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location ✓ Fresh Air Intake ,. 3 inch Plumbing Vent through roof minimum 18 inches ,/, ' Roof Complete/Exterior Finish Complete V Platform at all exterior doors4.4 Handrail 4 or more risers Guards at stairs, decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more - /ft/ Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches 17 Deck Bracing/Handicapped Ramp Compliant Grade awy from foundation 6 inches with 10 feet /' 6 inch clearance to sill plate t/ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight t Safety glazing/Win w in stairwells safety gl; ink ,� Interior Smoke D ectors/Carbon noxid,'Ietectors Every level: Ev ry Bed r m: Outside every bedroom rea: • Inter Connected: Battery backup: \J Attic access 30 inches x 22 inches x 30 inches(height)in accessible area 7 Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures :,-- Foundation insulation to floor/Sticker on Panel s Duct work sealed properly/Blower Door Test Certification V / Floor truss, draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area ‘,/— Furnace/Hot Water Heater operating f Low water shut-off boiler t,/ Relief Valve(s) installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical; Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles 4 Flex Gas Pipe Bonding As Built Septic System/Sew- D-,. . - :'action Sticker Site Plan /Variance required V Flood Plain Certification, if required f I Okay to issue C/C or C/O[Temporary/Permanent] [ L:\Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11 e Air Leakage Property Organization HERS Unknown Grajny Consulting. LLC Confirmed 45 Meldon Circle 518-221-3240 06/25/15 Queensbury, NY 12804 Stan Grajny, PE Rating No:0519155 Rater ID:5609922 Weather:Albany, NY Builder 45_Meldon_L The Michaels Group MichaelsGroup_45MeldonQueensb ury_NYESH_T2_062515.blg Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.13 0.11 ACH®50 Pascals 2.49' 2.49 CFM®25 Pascals 790 790 CFM 50 Pascals 12401 1240 Eff. Leakage Area (sq.in) 68.1 68.1 Specific Leakage Area 0.000131 0.00013 ELA/100 sf shell (sq.in) 0.97 0.97 Duct Leakage Leakage to Outside Units Ducting CFM®25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM® 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units I CFM25/CFA Total Duct Leakage I 0.0761 Ventilation Mechanical I Exhaust Only ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-20101 Total Recovery Eff. (%) 0.0 Rate (cfm) 67 651 Hours/Day 24.01 24.0 Fan Watts 30.0 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the'whole-building' requirement under that version of the standard. Both values incorporate any appropriate'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate- Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. dor\ Foundation Inspection Report aft Office No. (518) 761-8256 Date Inspection request received: b VI 115 Queensbury Building&Code Enforcement Arrive: am/• i Depart am/ m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial-. f►l: NAME: M1['GU i& 6n PERMIT#: I '" LOCATION: 5 ' ith:)S INSPECT ON: 1221 TYPE OF STRUCTURE: A ver, s,•d Comments N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. •Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/9/2014 ��j Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury, NY 12804 Date received: 7_\ 15 NAME: M'comas C5tYc LOCATION: 15 MrAricvn PERMIT#: 11— Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: r) Craig Brown, Zoning Administrator Notes: L:1Sueliemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Admin istrator.doc