2014-643 TOWN OF QUEENSBURY
woo742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20140643 Date Issued: Thursday, March 12, 2015
This is to certify that work requested to be done as shown by Permit Number P20140643
has been completed.
Location: 17 DINEEN Rd
Tax Map Number: 523400-289-007-0001-062-000-0000
Owner: BEVERLY& RICHARD BELLIZZI
Applicant: BEVERLY& RICHARD BELLIZZI
This structure may be occupied as a:
Enclosed Porch By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property 4
owner of the responsibility for compliance with Site Plan, Variance, or 1611t
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
li Oy
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140643 Application Number. A20140643
Tax Map No: 523400-289-007-0001-062-000-0000
Permission is hereby granted to: BEVERLY&RICHARD BELLIZZI
For property located at: 17 DINEEN Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: BEVERLY& RICHARD BELLIZZI Enclosed Porch
17 DINEEN Rd Total Value
QUEENSBURY NY 12804-0000
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2014-643
Enclosed Porch/Breezeway 176 sq.ft.
$50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,December 29,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To of Que sb • 4 + ,d. ! ember 29,2014
SIGNED BY - t for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
ACCESSORY STRUCTURE APPLICATION Received
DATE bex I$) 02014 Tax Map ID (9,8 ° ‘ - / -e.0
TAX MAP ID Permit No.L G 1 b 20.14 3
Permit Fee .SI ,►�
ZONING Rec Fee
H1sroRic SITE Yes A No Approvals
SUBDIVISION NAME ` I Lot#
APPLICANT iR\cJ AIZJ bet 11 z Z+ OWNER I/Me--
ADDRESS 17 SCJ iii on USC ADDRESS
lite 6-toeoe, iIy an(
PHONE I B - (D O 1 --(:2(-17c3 PHONE
CONTRACTOR ( I i€- she. ISCOST OF CONSTRUCTION(ESTIMATED): $
ADDRESS: BUILDING ADDRESS:
PHONE: Seta - 307 •- /S73
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE PHONE
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
Boathouse 1°'floor sq.ft. 2"4 floor sq.ft. Total sq.ft. Height
Boathouse with Sundeck •
Deck
Detached Garage(#of cars_)
Dock
Pole Barn
Porch-open
"Porch—3 season,Covered,Enclosed jGP kelk
Shed
Other Accessory Structure(s)
**Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone
DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the
application, plans and supporting materials are a true &complete statement description of the work proposed,that all work will be
performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local
zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy
✓I have read and agree to the above: Print Name: I ' Q//1r 2 z� Date: /-qbgbY
Signature: —I Al; Date: /Z118/V
1
Town of Queensbury Building&Codes Accessory Structure Application July 2014
ACCESSORY STRUCTURE APPLICATION (Requirements, Notes, Changes)
REQUIREMENTS:
1. Two(2)sets of the following documentation with the application and fee:
a) Plot plan drawn to scale with the use of a survey map, if possible (40 scale=40 feet)
b) Indicate proposed structure(s),showing setback dimensions from all surveyed property lines
c) Show location of all existing structure(s)on the property
d) Show location of water supply(well or water lines)
e) Show location and configuration of septic disposal system or sewer line.
2. Structural drawings to include: Floor plan; Foundation plan, Cross Sections, Elevations
3. Registered Architect or Engineer's stamp, signed &sealed for residential additions/alterations and any commercial
construction costs over$20,000
NOTES:
1. A permit must be obtained before beginning construction
2. This permit is for any structure other than residential principal structure (house) to include, but not limited to: garage,
shed, dock, deck, carport, pole barn, greenhouse, etc. Refer to Informational Brochure No. 3 —Accessory Structures —
Sheds/Fences.
3. Changes to Plan—Any changes prior to or during construction will require submittal of amended plans (review and re-
approval are necessary)
4. Withdrawn Permits: 20%of the initial fee is retainable by the Town. No fee is refundable after 1 year from initial application
date.
5. Additional review: All applications are subject to Zoning Administrator, Code Compliance and Structural Plan Review.
CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011(INFORMATIONAL):
Residential Building Code
• New driveway requirements for structures located over 300 feet from main road
• Spray foams are allowed to be exposed in rim joist box only,must be covered by 15 minute thermal barrier all other areas;
• Protection against decay requirements
• Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing
over steps
• Vent stacks must be 18 inches minimum above roof for all structures
New Electrical Requirements
• Arc fault breakers required in all habitable spaces for receptacles
• GFI protection for all other receptacles in kitchens, bathrooms, garages and unfinished basements
• All receptacles must be tamper resistant
• Carbon Monoxide detectors must be located within 15 feet of sleeping areas;
• All corrugated stainless steel piping must be bonded to the common ground for electrical service
New Energy Code
• Blower door tests required by credential contractor or structure inspection by air barrier supplier and certified compliant
• Programmable thermostats required
• Lighting must be 50%energy saving light bulbs
• Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit
• ResCheck inspector's checklist must be available at time of insulation inspection
2
Town of Queensbury Building&Codes Accessory Structure Application July 2014
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm De.art: �``_\_m/pm
Date Inspection request received: Inspector's Initials: art
NAME: PERMIT#: `(40"6
LOCATION: 17 I)iN ,C-lel i DATE: _—
TYPE OF STRUCTURE:
Comments:
Yes No NIA
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent thro�h roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs, decks, patios more than 30 inches above grade
Guard at ec ,stairwell c e inches oa more
Guard at deck, porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim I doors I main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height) in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation to floor!Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss, draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical; Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required /
Okay to issue C/C or C/0[Temporary/Permanent] p f
c iksS kb S nQ 3,1)[5 m e toe
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised
January 7, 2008; Revised 6/26/08; Revised 12/22/10, Revised 04/13/11
7-? '-‘Town of Queensbury-Building- ode Enforcement
Office No. 518) 761-8256
Framing I Firestopping Inspection Report
Inspection request received:
Name: Inspected on: i
Location: ( 3 ,Jlr- RI) Arrive: C:C a.m.l p.m.
-,j
Permit No.: �[ `-1 -5 Inspector's Initials:
TYPE OF STRUCTURE: 1 7.��
Y ` 'N N COMMENTS:
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Truss Specification Provided
Bracing/Bridging �
Joist hangers V
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
9/I
•
Firestopping
Penetration sealed 7r `� vu
16 inch insulation in cavity min. l
Garage Fire Separation �+ r VVIHouse side'/2 inch or 5/8 inch Type X • �.ry ,
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing / Firestopping Inspection Report
I
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: / 36
P
Queensbury Building&Code Enforcement Arrive: am/pm Depart: • _ i/pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: _ 1
6ett;2-7.; Do1`f"
NAME: n PERMIT#:
LOCATION: � -K4/ INSPECT ON: 3n /c)-0/5/
/4ir
TYPE OF STRUCTURE: l rt-�� F5v-P-Q61
Comments
N N/A 670k. 5A1
•otings
Piers309 /c/S
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc