2014-649 441TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20140649 Date Issued: Thursday, March 19, 2015
This is to certify that work requested to be done as shown by Permit Number P20140649
has been completed.
Location: 777 QUAKER Rd
Tax Map Number: 523400-303-019-0001-061-000-0000
Owner: STEWARTS SHOPS CORP.
Applicant: STEWARTS SHOPS CORP.
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the property rei.9 4 4/pct
owner of the responsibility for compliance with Site Plan, Variance, or
other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement
or Zoning Board of Appeals.
TOWN OF QUEENSBURY
`ora
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20140649 Application Number: A20140649
Tax Map No: 523400-303-019-0001-061-000-0000
Permission is hereby granted to: STEWARTS SHOPS CORP.
For property located at: 777 QUAKER Rd
in the Town of Queensbury, to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: STEWARTS SHOPS CORP.
Commercial Alteration $50,000.00
P.O. BOX 435 Total Value $50,000.00
SARATOGA SPRINGS,NY 12866-0
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2014-649
Comm. Alt.
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,December 31,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To Que sb 4 W• . , _ : -. ., l ecember 31,2014
`.4
SIGNED BY t for the Town of Queensbury.
Director of Building&Code Enforcement
#1-1/7
PRINCIPAL STRUCTURE APPLICATION Office Use Only
DATE ` r Received
�� / ,, Tax Map ID ,3 03. 11r 1-col
TAX MAP ID JC? 19 l-CP/ Permit No. 14-1-1,2</c1
Permit Fee )75 DO
ZONING Rec Fee
Site Plan#
HISTORIC SITE Yes No Subdivision#
DEC2 9 »1
SUBDIVISION NAME Lot#
TOWN Ba RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS, INCLUDING SINGLE FAMILY DWELLINGS,
DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR
MANUFACTURED&MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE.
APPLICANT ) JI II .OWNER aPPL(con
ADDRESS Lix, 1 J A ADDRESS
. r/72g5
v?I- /3-0 Ligt,
6
PHONE/E-MAIL " CA PHONE/E-MAIL o�0
E-MAIL
�r�f,( orAc!, �j L�UJa7 C077
CONTRACTOR CIPpLI (CLUE COST OF CONSTRUCTION(ESTIMATED): $L
ADDRESS: BUILDING ADDRESS: 7'17 a/ate/ ted.
PHONE/E-MAIL p J /y ��
CONTACT PERSON FOR BUILDING& CODES COMPLIANCESJI f)1 r/ i (//� PHO r/-4..210
c/LI/5
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
New Addition Alteration 1st floor sq. ft. 2nd floor sq.ft. Total sq. ft. Height
Single Family
Two-Family
Multi-Family
(#of units
Townhouse
Business Office
Retail - Mercantile
Factory- Industrial
Attached Garage
(#of ) t
Other
1
Town of Queensbury Building&Codes Principal Structure Application July 2014
If commercial or industrial indicate name of business 5.10,06Ve5
Proposed use of building or addition r'%1 l
Source of heat (circle one) Gas Oil Propane Solar Other
Fireplace: complete a separate application for Fuel Burning Appliances & A/a-
Chimneys
Are there structures not shown on plot plan? Nr�
Are there easements on the property? NQ
Site Information
a. Dimensions or acreage of lot J/�t7
b. Is this a corner lot? e5
c. Will the grade be changed as a result of construction Yes 1 No
d. Public water or Private well
e. Sewer or Private Septic System CC
Value of all work to be performed (labor or materials) $ 000
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement / description of
the work proposed, that all work will be performed in accordance with the NY State Building Codes, local
building laws and ordinances, and in conformance with local zoning regulations.
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occcu..ricy.
I have read and agree to the above: PRINT NAME ..�l-/ / / r . .f £ DATE
9 ,1 ' 12-12140
SIGNATURE: Ii/ I/ /lig. lk •TE 2/2t#4
FOR OFFICE USE ONLY
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Aa"..
Special Conditions
2
Town of Queensbury Building&Codes Principal Structure Application July 2014
Town of Queensbury Building &Code Enforcement
Office No. (518)761-8256
Commercial Final Inspection Report
Inspection request received:
Name: k <.\ Inspected on: -- ' --
Location: g UCO(31)/ Arrive:
C)%,•441,7
Permit No.: 14i— '°1 Inspector's Initials: 41111111!S-
• COMMENTS
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"!Roof Complete
Exterior Finish/Grade Complete 6"in 10'or Equivalent
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch/Step Risers 7"!Treads 11"
Vestibules For Exit doors>3000 sq.ft. .1
All Doors 36 inch w/Lever Handles/Panic Hardware,if required 'I
Exits At Grade Or Platform 36"(w)x 44"(I)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap!Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%> 1000 sq.ft.
'/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets I Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond [Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded v/
Site Plan/Variance required (� `
Final Survey, New Structure/Flood Plain certification, if req.
As-built Septic System Layout Required or On File Yj)9
Building Number or Tenant Address on Building or Driveway 4" ,gyp
Water Fountain or Cooler ��i
Building Access All Sides by 20'/Drivable Surface 20'wide
Special Inspections/Engineer or Architect Approval
Okay To Issue Temporary or Permanent C/0
Okay To Issue C/C
Commercial Final Inspection_11 27 12
Inspection Form
Town of Queensbury Fire Marshal O Periodic Inspection Date:3/„'f S J
Time:
I
742 Bay Road,Queensbury NY 12804 o Re-InspectionI Li
518 761 8206/518 761 8205 a CO Inspection Permit#:
Fire Marshals Representative
�C MJ Palmer Business Name:
Location: ) '7 •..1 41L 2 - o
GK Stillman Contact:
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 _ NOTES
_ Exit Enclosure FC 1020&FC1029
Exit Discharge FC 1024&FC1029
Locks and latches FC1008& FC1029.2
Sign: Normal FC 1011 &FC1029
Sign: backup FC 1011.5.3&FC1029.7.5
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11 F ✓'
Secondary Aisle Width FC 1025&FC1029.11
FIRE EXTINGUISHER: Hung FC 906 4
Inspection of extinguisher FC 906 03,4-y01
EVAC Plan FC 404.2
TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907
CO detectors FC 610
Clearance to Sprinkler/Ceiling FC 315.2.1
18" / 24"
EVAC SIGNS IN Rooms FC 404.6 (R1 &R2)
Fuel Pump Warning Signs FC2205.6
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATELY
Vacant Buildings FC 311
Emergency Disconnect FC 2203.2 21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual DATE: OK NC
HVAC Shutdown
Sprinkler System Annual Fire Marshal Inspection Comp ete
Sprinkler FDC + CO may be issued 5 with
Kitchen Suppression Semi Annual Building&Codes approval
Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual 1�
Knox Box:installed/checked FC506 MAR 10 20`
Operating Permit, if required will be issued after Fire Marshal
Completion of Inspection Town of Queensbu
Town of Queensbury Building &Code Enforcement
U�S , ��
Office No. (518)761-8256
Rough Plumbing 1 Insulation Inspection Report
Inspection request received: 4240
Name: (* &)Ci.✓1 \S Inspected on: 2-12ip [I 3
Location: �-�-`I- EJG,kcSbV Arrive: AA,
Permit No.: � ' — (ez -C\ Inspector's Initials: ft'
Type of Structure:
COMMENTS
Y N NA
Plumbing under slab
• Tzif
Rough Plumbing 1 Nail Plates
Plumbing Vent/Vents in Place tog� toy 8 25b
--
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent StUC' "-'' ViZ'n -S
Air/Head •
5 P.S.I. or 10 ft. above highest connection for 15 minutes S\r -
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/ Residential Check/Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
Rough Plumbing/Insulation Inspection Report
Town of Queensbury Building &Code Enforcement 1 \ — 1
Office No. (518)761-8256
Commercial Final Inspection Report . _)c.,\-\K;
Inspection request received:
I
Name: "1---V:=1_ 1
j � R.T z__�—
� _ Inspected on: _
Location: —771 ( :A\�, c2, ) Arrive: it - r: i :
Permit No.: \ —CoLP Inspector's Initials: -�
/
COMMENTS
Y N /VA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete ,5f'0cx,c2, E��, F>. I
Exterior Finish/Grade Complete 6"in 10'or Equivalent :fitJNiz-
Interior/Exterior Guardrails 42 inch Platform/Decks
Interior/Exterior Balusters 4 inch Spacing Platform/Decks
Stair Handrail 34 inch—38 inch/Step Risers 7"/Treads 11" /
estibules For Exit doors>3000 sq.ft.
II Doors 36 inch w/Lever Handles 1 Panic Hardware, if required r
Exits At Grade Or Platform 36"(w)x 44"(1)1 Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve, Heat Trap I Water Temperature 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System
Fresh Air Supply for Occupancy I Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2 doors > 10%>.1000 sq.ft.
'/<Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors
Ceiling Fire Stopping,3,000 sq.ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 inch,Checkout 36 inch
Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides]
Active Listening System and Signage Assembly Space
Final Electrical/Flex Gas Piping Bonded
Site Plan/Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4"
Water Fountain or Cooler
n
/Building Access All Sides by 20'/Drivable Surface 20'wide
/ Special Inspections/Engineer or Architect Approval
\+ Okay To Issue Temporary or Permanent C/O
Okay To Issue C/C
y
Commercial Final Inspection_11 27 12
alt
T-7:\A-( kj --±kat
Inspection-F rm covr ;nc f�
Town of Queensbury Fire Marshal o Periodic Inspection Date: 0Z VLC Time; . 1/3 ) & I Y
742 Bay Road,Queensbury NY 12804 a Re-Inspection I�
518 761 8206/518 761 8205 CO Inspection Permit#: `' e)1 1-/--0
1/11 66
l�FireMarshals Representative
J Palmer Business Name: 5Ie- �%`rrr.,
Location: �7 -7 c «
� Lr- K (- 3rn>
i GK Stillman Contact: 737rv./41-c 1 I t-t Co 36? — 967/E
Type of Inspection N/A Yes No
EXITS: Exit Access FC 1014&FC1029 f NOTES
Exit Enclosure FC 1020&FC1029 f
Exit Discharge FC 1024&FC1029 .�
Locks and latches FC1008& FC1029.2 1
Sign: Normal FC 1011 &FC1029 .-•-•----
Sign: backup FC 1011.5.3&FC1029.7.5 -�
AISLES:
Main Aisle Width FC 1024/1025&FC1029.11
Secondary Aisle Width FC 1025&FC1029.11 /
FIRE EXTINGUISHER: Hung FC 906 ..---
Inspection
Inspection of extinguisher FC 906 _-----.".
EVAC Plan FC 404.2 ...-------
TRUSS
./TRUSS ID SIGNAGE FC 505.3
EMERGENCY LIGHTING:
Interior FC 1006.3&FC1029.8
Exterior FC 1006.3 /_
Clearance to Electrical FC 605.3
Electric Wiring Enclosed/Labeled FC 605.3.1
Combustibles in Equipment Rooms FC315.2.3
F.D.Signage- FC 510
No Smoking Signs FC 310.3 �------.
Storage FC 315.2
Compressed Gas FC 3003
Vehicle Impact Protection FC 312.1
Interior Finishes FC 803-804
Smoke Detectors FC 907 s4----"
CO detectors FC 0 /
Clearance to Sprinkler Ceiling C 315 .2.1 ' a.,,,,,
18" 24" X — 1� 111 rtr1 l
EVAC SIGNS IN Rooms F 04.6(R1 &R2) ,,------
Fuel
.— c 7 c---,..,,,4
� ) If3 �f
Fuel Pump Warning Signs FC2205.6 !�
Fuel Station Emer Procedures FC2204.3.5
Exterior Storage FC 315.3 REINSPECTION DUE APPROXIMATELY
Vacant Buildings FC 311 ,✓ _
Emergency Disconnect FC 2203.2 , 21 DAYS
SYSTEMS: FC 901.6 Insp OK NC DATE: OK NC
Date
Generator Annual DATE: OK NC
Hood Installation
Elevator Semi Annual
FIRE ALARM Annual 1/ DATE: OK NC r
HVAC Shutdown
Sprinkler System Annual
Sprinkler FDC
Kitchen Suppression Semi Annual /
Fuel Island Suppression Semi Annual
Hood Cleaning 3-6-Annual
Knox Box:installed/checked FC506
•
Operating Permit, if required will be issued after 1 , .,
Completion of Inspection
(14),
7114)k-
---(
Commercial Final Ins coon Re XriA---LE)/-/—etrite_a°&;
Office No.: (518) 761-8256 Date Inspection 4i-ied: a 4 _Queensbury Building & Code Enforcement Arrive: 7 OaDepart. ,�. a /p� r �'�
742 Bay Road, Queens ry, NY 12804 Inspector's Initials. -,c
_ L = 7
/ _ r
NAME: 5/1-6.- �` PERM! •. �%I
LOCATION: 7 7 7 Qu:_IOr :1----- DATEi ,, Sar L 7v.,t-,-fr.1
COMMENTS:
YN NA
Chimney/"B"Vent/Direct Vent Location /
Plumbing Vent Through Roof 6"/Roof Complete �r ~ /�//,, '' j� S` ..
Exterior Finish /Grade Complete 6" in 10'or Equivalent �1 rm/ V I`
Interior/Exterior Guardrails 42 in. Platform/Decks 2/ /
Interior/Exterior Ballisters 4 in. Spacing Platform I Decks / ( J�
Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" �/
Vestibules For Exit doors> 3000 sq. ft.
All Doors 36 in. w!Lever Handles I Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44° (1)/Canopy or Equiv. �oV-___
Gas Valve Shut-off Exposed &Regulator(18")Above Grade / To -3 i�sts' I� `NA
Floor Bathroom Watertight/Other Floors Okayi-aV
Relief Valve, Heat Trap I Water Temp.110 Degrees Maximum / C ; �
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System lc-\tUJV �
Fresh Air Supply for Occupancy/Ventilation Combustion — 'tJt' 1-55\-vim _
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site ��� -nV.___ Lpw`�
Oil Furnace Shut Off at Entrance to Furnace Area yJ\a,_—__
Stockroom/Storage/Receiving/Shipping Room (2 hr.), 1 %doors �(--
> 10% > 1000 sq. ft. .
3/Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/ Fire Doors
_ Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame
Attic Access 30"x 20"x 30"(h), Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath I Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36" J
Handicapped Ramp 1 Handrails Continuous/12 in. Beyond [Both
sides]
Active Listening System and Signage Assembly Space /
Final Electrical I Flex Gas Piping Bonded
Site Plan I Variance required
Final Survey, New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway 4"
—)Water Fountain or Cooler
Building Access All Sides by 20'/Driveable Surface 20'wide z
Okay To Issue Temp. or Permanent CIO \
7 .Okay To Issue C/C
L:\Building&Codes Forrns\Building&Codesllnspeciion Forms\Commerc ial Final Inspection Report.doc Revised January 7,2008,;.'
j:
K
Sit--`o cem
Rough Plumbing / Insulation Inspection ' eport /
Office No. (518) 761-8256 Date Inssection req • ' c:, •d: Vokei4.4/S--
Queensbury Building & Code Enforcement Arrive: CY: • .'i�i'�
742 Bay Road, Queensbury, NY 12804 Inspector's Initia, .
NAME: 5-kitx.)4 PERMIT #: c20/4- 4/
LOCATION: gel/17-S' INSPECT OK: : / an •
TYPE OF STRUCTURE: 6Afk.
i'
--� _
N N/A 6Etaor(
lumbing under slab
Rough Plumbing / Nail Plates 6e4eP/lln'611
Plumbing Vent/Vents in Place 8`52_0641
11/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain /Vent
Air / Head
5 P.S.I. for 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I. for for 15 minutes
Insulation / Residential Check / Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door / Window Sealed (No Insulation)
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
Blower Door Test
Air Sealing
COMMENTS:
Rough Plumhing_Insulation Inspection 02 05 13
Town of Queensbury Building & Code Enforcement kA.)�( g -10
Office No. (518) 761-8256
Framing I Firestopping Inspection Report
Inspection request received:
Name: S 4-6 U- 1''*S Inspected on: 7-" rMA 1
Location: 7 7 7 cIa0 Kg-r/UCS Arrive: lv► c�. •.m.
Permit No.: /'(/-L .i? Inspector's Initials: 11111.7P-
TYPE
f
TYPE OF STRUCTURE:
a- ‘ 0 5\ =-C i U iS
V. ttic iY N NIA
COMMENTS:
Access 22"x 30"minimum
Jack Studs/Headers V4\V--7-% T\ c z �--- \--lk, �r�
Truss Specification Provided � �f�J
Bracing/Bridging "—S Cj- 2 %LF 77 `LY____
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
F' e separation 1,2,3 hour
it
wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side'/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
Design Professional Sign-off,if required