Loading...
SOLAR-000770-2016 } TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (5I8)761-8201 Community Development-Building& Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000770-2016 Date Issued: Wednesday, February 15, 2017 This is to certify that work requested to be done as shown by Permit Number SOLAR-000770-2016 has been completed. Tax Map Number: 316.9-1-27.1 Location: 271 BIG BAY RD Owner: Beth Portuese,THOMAS PORTUESE Applicant: Beth Portuese This structure may be occupied as a: Solar Panel System No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the j 4 �. property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000770-2016 Tax Map No: 316.9-1-27.1 Permission is hereby granted to: Hudson Solar For property located at: 271 BIG BAY RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Beth Pormese Solar Panel-Residential $29,000.00 Owner Address: 271 BIG BAY RD Total Value $29,000.00 Queensbury,NY 12804 Contractor or Buildees Name/Address Electrical Inspection Agency Hudson Solar 13 Hook RD Rhinebeck,NY 12572 Plans&Specifications Solar Panel System No Rafter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,November 9,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the ae iration date. Dated at the Town ueens { / 4 W e n , ovember 9,2016 SIGNED BY: (A,~K�/ for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE ONLY D TAX MAP NO. PERMIT NO.tQ1 A4 , 'k'k0 . 2nt to NOV 0 4 2016 FEE PAID 'r�O BLDG.R CODES APPROVAL TOVVN OF = ---�Y1W CUA,_�L�o ' ' 6UILDWG&CECj SRY ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO IN ECTLIIONS tgi-L BE MI ADE UNTIL THE APPLICANT HAS RECEIVED A VALID'BIUILDIING PERMIT. OWNER: Ly'7/v�1 f o Y' ( 'L r— Sem INSTALLER/BBk9ER: ADDRESS: 27x11015/ 8YM Qo/•'j-1,/4•u6-1^J4io7,)�ADDRESS: �p�/oo,/k (Sdh JAC AC1(ACL'/K% p fz571 PHONE NOS.�7�61 6 C,b — 06 7 V1 ' PHONE NOS Dob 7 5 2 —76.7 2 O k t I7t LOCATION OF PROPERTY: 5-"4- 65 'Aj Y67� SUBDIVISION NAME: /n /^� V LOCATION OF PROPOSED CONSTRUCTION NAND/OR INSTALLATION: Z 71 (3 1 99ICF 1 4JL LteC r�56 u p t ESTIMATED COST OF CONSTRUCTION: $�7�Do'0'cOANY OTHER ACCESSORY STRUCTURES ON PROPERTY? 11 O IF YES,PLEASE LIST: pp ll // ff// CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: S Ac�z-K ¢✓PHONE.0-) y5?-76Q eXT , � Tk 1�FLOOR 2N°FLOOR TOTAL PROPOSED PROPOSED CONSTRUCTION SQ.FT. SQ.FT. SQ.FT. HEIGHT FT.81N. 1/ OPEN PORCH J( JeSLf(kh DECK 3 SEASON,COVERED OR ENCLOSED PORCH' IJP BOATHOUSE f O h BOATHOUSE WITH SUNDECK DOCK Q c q SHED I l POLE BARN DETACHED GARAGE(NO.OF CARS:_) OTHER ACCESSORY STRUCTURE: 'CONSIDERED FLOOR AREA 8 MUST COMPLY WITH FAR(FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work Is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As- Built Survey by a licensed surveyor,drawn to scale showing actual location of all new construction. I have readnd agree to As above. QUESTIONS 7 CALL 761-8256 OR EMAIL (� �r Ca)Queensburv.net Signed � Dated: codes � 2 6 VISIT OUR WEBSITE FOR MORE INFORMATION Namerride(Printed) NI( L I o e www.gueensburv.net Dec. 29. 20166 9: 56A 11 A No. 6163 P. 3/4 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. �casly� that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions, Owner: Date: Tom $Beth Porluese 12/22/2016 Occupant: Location: Solar PV System 271 Big Bay Road Occupancy:I-ngle Family Dwg. Queensbury, Warren Co. NY � Applicant: Hudson Solar 13 Hook Rd Rhinebeck, NY 12572 Joseph A.Holmes No. ,14400720*'EL Equipment: 29-Solar Modules; 1 -76001watt Inverter, 1 = Production l leter; 1 -Back Fed Breaker This certificate applies to the electrical wiring to the electrical equipment listed Immediately null and void. This cartRrate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use.oecupenuy or Ownership inspeckn. No warranty is expressed or implied as to the mechanical safety.efg- of the property Indicated above,this certificate shall be Immediately null and void. clancy or fitness of the equipment for arty particular purpose. This ceMc:ale shall In the event Nat this certificate becomes invano based upon the above conditions, ba valid for a period of one year from the above holed data. Should the elec(nwl this cartlllcate may ba revalidated upon relnspettibn by Middle Department system t0 which this cenmcate applies De altered in anyway,Including but mt Ilmlt- Inbpection Agency,Inc. An epplieeNon lo!inspection moat he eubmided to Middle 1 thl lo,the introduWion of atldaional elecaka equipmaM and/or the replacement of Department Inspection Ageney. Inc.Io initiate the inspection antl revalideuan. any of the components installed as W N!above noted date,mis etnlficate Shall be process. p tet.call be charged for thio eeMce. PROPERTY LINE&SETBACKS DPHOTOVOLTAIC(SOLAR ELECTRIC)SITE PLAN paS.N SpUJ CONF pENT4 6PR.PWETARY �ti�11 N DC Disconnect Utility Meter =1� HUDSON SOLA Inverter Board ...... Main Service Panel 13 Nook Road.Rl--k NY 12572 --dswsdarcan j— C Portuese, Beth WL L...b- 271 Big Bay Road Queensbury, NY 12804 Warren County t� Town of Queensbury .-. Phone 516-680-0674 CV v) Phone N �11tn Betais Site Site Map- C 8,845Wp DC, 7,600W AC O CL House 29 LG 305 modules on new 0 south roof. Contractor to install Q attic to basement conduit —1 E chase, HS to advise for whats 0 70 (D needed. Conduit penetrates pinto attic drop into conduit d chase to basement inverter Photovoltaic Array tim board on north original Mounted on Aluminum Rack basement wall.AC to new MSP N4) m a T N CU for a back feed breaker C1 IZ Beta°2 PHOTOVOLTAIC ARRAY LAYOUT m 39 ' - 11 " Ma° Nco D E V(J 11.. E 1� -1"'-g Pe—it q V 1`I"J- Utility Account H Service Type Underground/Overhead NOV p 4 Dtitity k 201 Utility Meter NunBer xx xxx xxx 1 Make/Model/Type CL 200 Service Detall 1 Ph 240VAC 200A TOWN OF QUEENSBURY LEGEND UNGRGUNEnsu BUILDING& Ilatlon Color=Block/Red/DHue/Brown OR CODES .nge/Yell.• —— GROUNDED CGNDUCTOR Be—] Insulatl.n Color=Vhlte/Grey MODULE MOUNTING . TOWN OF QUEENSBURY EIX11a104T TAQ1N11DaG GWRLT6i CEGD BUILDING DEPARTMENT 1—ation Cglgr=Green/Bare 90MIN13 MECTIRME CDMJC7M(Gm Oil ed examination,compliance Insulotion Calor-Green/Bore with our commen s shall not be construed as Irreverslaly spliced EGC installed As per NEC 25a64(CXU q jy�� and terecnates at GEC-GE I unlesa noted ctherwise indicating the 0ais and specil ¢tions are in GE} Installed near DC disconnect per NEC02008 full compliance with the Building Codes of 69D.47(D)except a5 conditions of NEC®2008 690.47(0) Exceptions No.l and Nat apply. New Yo State. AC/DC=A(I Conductors iHVN-2 Stranded Copper unless noted otherwise Rai Nodule PV Conductors=USE-2 Supplied by H—Facturer SS Bdt foot All xtensions a - ane apper Hotlule Grounding=d10 Bore Solid Copper Lag Screw SSIosYJng Deckle Lay-in-LV05 band quipnent rpuntl to ModiAe/ack g Co.vtit=Alt Cvd�it Schedule 40 uriess noted other+ise • =UL listed Connections-All Torqued to Soec All Equlpnent to be labeled In accortlanCe Nth NECO Franhg 2008 article 690 TOWN OF - UEE6�,{SQURY SHEET of -- A Dr°°ter DK °°Se 102116 I °''`, °, G C S Q L PT, Kon ¢ratter �te � Rr�b,an Brafter nate Reviewed y:.�� ReeSron Bra,ter Bate 7'� / RevK�on grafter Bate , ate: Ar. RrvKun iter Wte `w, R-- Brafter pate Revsmn Matter Dote HU0.50N SOLM(:ONFbENaAl6PROPg1ETARY HUDSON SOLA �II11\ 13 Mook Roatl,RNrcaecN NY 125]2 —d—on Pr j Portuese, Beth La�atian 271 Big Bay Road Queensbury, NY 12804 Roof Mounted PV Array Warren CountyTown of Queensbury Rack = Snap N Rack PSC Certified Phone 516-680-0674 29 LG 305N1C-G4 305W Modules List Inverters 8,845 Wp Total System Inverter 741 Phone Sys—D-4Located on North Total System original basenent PV Output Meter Three Line Drawing- . - - - - - - - - - - - - - - 7,600V 240V Monitoring: S S W Wp DC 7 600 AC G G G G G G G T, AC Output Placement Ethernet Hard wired to N 100A 240V AC customer provided RJ45 near SE7600A-US invrter board Located on 29 LG 305 modules on new 1 2 3 4 0 0 0 13 14 15 \LA Inverter Board south roof. Contractor to install SolarEdge U5934-XL-BCG attic to basement conduit M1 chase, HS to advise for whats Power ❑ptimizer - - - - I - F - I - F LINE LDnn P320 _ _ _ _ _ _ _ Al needed. Conduit penetrates into attic drop into conduit + Wh chase to basement inverter input board on north original 1 String of 15 LG305N1C-G4 Modules = 4,575Wp — — — — — — — — — — MS 350V DC, Max Current 15A DC r - - - - - - - - - - - - - - - - • - . - - . - . . . . . . . . . . . . . . . . . . . •- —� basement wall.AC to new P • • ' a for a back feed breaker 3/4" PVC out Inverter •_ I - - - - - - - - - - - - - - - - - - - - - - G G . . G . . . . .• EMT In Serial Number 3/4" PVC °w Y G G G G 2 Red #10 C+) 2 Blk #8 1 2 3 4 0 0 0 12 13 14 ; 2 Blk #10 c-) 1 wht #8 1 Grin #8 1 Orn #8 : I SolarEdge PoweP300ptimizer — + — + — I — F — F — { I MODULELG305 - 3/4" PVC _ _ -- _ - - - - - - - - A2 2 Blk #8 D V.0 40.1 - 1 Wht #8 Vmp 32.5V Main Service Panel ISL 9.93A National Grid 200A 240V AC 1 Grn #8 I ,np 9.39A Utility Meter Located on east I TnpCo -.0028 1 String of 14 Current Modules = 4,270Wp Located on North basement wall I Length 64.57• 350V DC, Max Current 15A DC ` " " ' " " ' ' Width 39.37' exterior wall Model- TBD Building Permit If 27 542 328 Breaker- 200A / TBDk AIR I Utility Accountfl TDP BOT I Service Type Overhead Dis/Rec # Wh TO , I Utility Meter Number 27 542 326 /f\ Make/Model/Type CL 200 National Grid 2QO I Service Detail 1 Ph 240VAC 200A Utility Grid LEGEND UNGROUNDED MOLITOR SE 7600A-US Electrical Specifications �\ — : I In..latlan Color=Black/Red/Blue/Broen/Orange/Yellae Maximum AC Output Current-32A 4/0 AL —————GROUNDED CONDUCTOR Maximum Output Over Current Protection-40A In-oti—Calor=Vhite/Grey SEC ............ EQUIPMENT GROUNDING 031<Dl1CDOR CM een/B =C ]...lath. olor Grare .stall Manual Version 4.0 I ..._... .. GROUNDING ELECTRO L,Q=MD I...lotion Color-Green/Bar irreversibly spaced EGC Ins--lith as per NEC 25a64(001 40 and terninates at GEC or GE�.unless noted otherwise GE. Inste led n as DC disconnect per cn 6908 690.47(➢)a cepteo candtiply aF NEL®2008 690.47(➢) • Ezceptions No.l and No.2 apply. - - - - - - - - AC/DC=All Conductors T—N-2 Stranded Capp- --noted otherwise PV Conductors=PV Vire Supplied by Manufacturer All Extensions 410 PV Wb. Customer to clear inverter board area, provide 1" Existing GE M.d.le Grounding=.10 Bare Said Copper Lay-in-Lugs bond Equipment Ground to Module/Rack conduit as a chase from attic to basement. Condit=All Candut Sched.le 40 W-s nate,otherwise All Toro—d to So— Customer to provide Internet In basement. HS to • =UL listed Connections-Au Equipment to be labeled in accordance with NECO advise customer about attic to basement conduit 200B article 690 chase installation. HS to verify roof dimensions, SHEET 1 of 1 Revision grafter Dote pitch and azimuth. a DK 102116 rc•m fter Date ¢mn Draftrr e Revaion Drafter Dote Revaion Orolter pore soon tHofter Oa,e rsion Drafter Date Revsion Ur—n- Date o 01 satyrs coNFID—At.n Prs 1HUDSON SOLAR , 6 „ 39 ' - 1116 " 13 HRok R,.d.RNnebeck NY 12572 r.rh.—elnr.con Pro,eet Portuese, Beth 8r.Tom toc°tlon 271 Big Bay Road Queensbury, NY 12804 Warren County 11 ,i Town of Queensbury Phone, 1 „ Phone 6 5 syst516-680-0674 em ortaRs Module Layout- 8,845Wp DC, 7,600W AC 29 LG305N1C-G4 a-kh0 D—kx SnapNrack Series 100 Not.. 7 rows of 5 minus 6 in 15 ' 1 landscape 26 ' - 06 " 4 ' 6 3 " Building Permit q utnity Account a 6 Service Type Underground/Uverhead Ois/Rec # Utility Meter Nunber xx xxx xxx Make/Model/Type CL 200 Service Oetnil 1 Ph 240VAC 200A LEGEND UNGROUNDED CONDUCTGR Insulation Color=Black/Red/Blue/Broin/Grunge/Yell.. —————GROUNDED CBNDUCTGR insvintion Color=Vhite/Grey ............ EDUIPHENT"'C""PG CQRDUCTM 11 ' Insulatian Color=Green/Dare CTRWQING 01CRd1IE CRNA TM(® insulation Color-Green/Bur Irreversibly spliced EGL Installed As per NEC 250.64(C)(U and ter .tes of GEC or GEJ unless noted otherwise GE I Inst.Betl nesconr DC diect per NECO2DO8 690.470)except a on clitioF NEC02008 690.47(0) Exceptions N..l and No.2 apply. AC/DC=AU Conductors THVN-2 Stronded Copper unless noted otherwise PV Conductors=USE-2 Supplied by H—F.cturer All Extensions lt10 USE-2 St,* nded Copper Modu!e Grounding=.10 Bare Solid Copper Loy-n-Lues bond Equlpnent Ground to Module/Rack Corxklt=Nl CoMut ScF—Ule 40 bless rested otherwise • =UL listed Connections-All Torqued to Soec All Equlpnent to be labeled In.c..rd—ce xIth NE ID 2008 Article 690 SHEET 1 of 1 A Dr=fter DK °°te 091416 B DK mte 102116 Re"rcon Oroftrr to Revision Dr.—, Date Revision ➢r 1— Dote rcon «er .ate Revision 0�°f<er <e Revlon —1— ➢Ate HumoN S—q,NEp)ENT)4L 6 PRomVA— HUDSON SO 3 9 , _ 1111 LA 16 IB Hao4 R°atl.RNrebeG HY I251 2 rrhuisonsMarc°n ro,eat Portuese, Beth&Tom amm 271 Big Bay Road Queensbury, NY 12804 Warren County Town of Queensbury Phone 516-680-0674 6 3 2 Phone 6 , _ 51 Syztrn Oetais Module Layout- 8,845Wp DC, 7,600W AC Matlule Drt°Rs 29 LG305N1C-G4 R—d g Deto" SnapNrack Series 100 Nates 7 rows of 5 minus 6 in 15landscape ' 26 / - 03 // Building Permit k 4 Utility account a Service Type Underground/Overheod Dis/Rec B Utility Meter Number Make/Model/Type CL 200 Service Detail l Ph 240VAC 200A LEGEND UNGROUNDED CONDUCTOR Insulation Color=Black/Red/Blue/Brom/Oronge/Yell,, —————GROUNDED CONDUCTOR Insulation Color=W hite/Grey ........... EOOPMENT CROUMUM CONDUCT"'"'C) 11 ' Insulotlan Color=Green/B,re (T2GUnm Fl ECTROZE CONDJCTER(GED Insulation Color-Green/Bar Irreverslblyspliced EGC Installed as per NEC 29064(O(U and terminates at DEC or GE{.unless rated th-r - GE# Installed n r DC disco-ect per NECO2D08 69a47(D)a cept ea ,nditi,nsn of NEC®2008 690.47(➢) E,ceptlonsxNo.l and Na2 apply' AC/DC=All Conductors THNN-2 Stranded Copper unless noted othe—l.e PV Conductors=USE-2 Supplied by Manufacturer All Extensions Y10 USE-2 Strandetl Copper Module Grounding=910 Bare Solid Copper Lay-In-Lugs band Equipment Grund to Module/Rack C—Ut=A11 Cc Lit Schedule 40,less noted othereise • =UL listed Connections-All Toraued to Spec All Equlpm- to be Labeled in ccord.—,Itl,NECO 2008 article 690 SHEET 1 of 1 A °°!t" DK °°t` 091416 B °'°`t" DK °°t' 102116 Revrs°.. iter Dote 5�on Drafter Date Reezion Drafter Date Re-- fter Date Rev— Drafter e Rev— Drafter Wt¢ —.tL 1 Detcil4 HUMONa—CONFIDENT]AL6eRORWt— PROPERTY LINE&SETBACKS PHOTOVOLTAIC(SOLAR ELECTRIC)SITE PLAN r DC Disconnect �— HUDSON SOLAR Inverter Board Utility Meter �,,, :.,,..: Main Service Panel 3 Mook Rood.R beck NY 12572 .�ludwnsolor;an Project /p� C Portuese, Beth \/\/ i E Loc Hon X Y 271 Big Bay Road Queensbury, NY 12804 Warren County S Town of Queensbury Phone 516-680-0674 Phone S Deteis Sitit e Map- 8,845Wp DC, 7,600W AC Nates House 29 LG 305 modules on new south roof. Contractor to install attic to basement conduit chase, HS to advise for whats needed. Conduit penetrates into attic drop into conduit chase to basement inverter Photovoltaic Array board on north original Mounted on Aluminum Rack basement wall.AC to new MSP for a back feed breaker De—2 PHOTOVOLTAIC ARRAY LAYOUT 39' - 11 " Building Pernit If Utility Account q Service Type Underground/Overhead Dis/Rec k Utility Meter Nunber Make/Model/Type CL 200 Service Detail 1 Ph 240VAC 200A LEGEND UNGROUNDED CONDUCTOR Insulatlon Color=Block/Red/Blue/Brawn/Orange/Yellow —————GROUNDED CONDUCTOR Detc4 3 Insulation Color=White/Grey MODULE MOUNTING ECUIPMENT GROUNDING CONDUCTOR(M Insulation Color=Green/Bar e ............ GRL3NDIN5 ELECTRODE CCNDLET R(GEC) Insulation Color=Green/Bar _ Irreverslbly spli ed EGC Installed ns per NEC 250.64(C)(U and te—K at es at GEC or GE I unless noted otherwise GE I Installed e n r OC drsco nect per NECO200B 69D.47(D)a sept a ConditionsoF FEC62008 690.47(D) EwceptionswNo.l and No.2 apply. AC/OC=All Conductors TMVN-2 Strantletl Copper unless noted otherwise `Maduie PV Conductors=USE-2 Supplletl by Manufacturer Rat All Ewtensions.10 USE-2 Strantletl Copper 3. SS Bdt Module Grounding=nID Bare Solid Copper Foot Lay-n-Wgs bond Equipment Ground to Module/Rock Lag Screw SS Asning UeWing Coro4rit=All Cadut Schedule 40 a .-noted otherwise • =UI_listed Connections-All Torqued to So- All Equlpnent to be labeled In accordance with NECO 2008 article 690 rrawhp SHEET 1 of 1 Reeismn A Droner DK Dnte 102116 -,on DrAr<er mm R-- rter L.1e Revsion Dra Fter Date Re✓bn .—ter Dote FI—ion Cter Date Sian or,ner mu Revismn Droner mte HUpSaN-SIXM C°NFbENT4L 8 PR fE! HUDSON SOLA _ 0 Hook Raad,Rh beck W 12512 r_bWsonsdnr.can "lett Portuese, Beth nd- 271 Big Bay Road Queensbury, NY 12804 Warren County Roof Mounted PV Array Town of Queensbury Rack = Snap N Rack List Certified ve ite s Phone 516-680-0674 29 LG 305N1C-64 305W Modules UL 1741 Phone 8,845 Wp Total System Inverter Board s'.trn Detal. Located on North Total System Three Line Drawing- original,i PV Dutput Meter wa(( 8,845Wp DC, 7,600W AC 7,600W 240V Monitoring: S G G iG . G AC Output PI°cenent Ethernet Hard wired to N Natr. customer provided RJ45 near 100A 240V AC p 29 LG 305 modules on new SE7600A-US inverter board Located on 1 Z 3 4 0 0 0 13 14 15 \LA' Inverter Board south roof. Contractor to install U5934-XL-BCG attic to basement conduit S to se for PowerSotrEdge❑ptiimizer — + — + — + — + LINE Ml LDAO needed. Conduit 1penetratests P320 _ _ _ _ _ _ A 1 into attic drop into conduit - - - + Wh chase to basement inverter Dc board on north original — .— — — basement wall.AC to new MSP 1 String of 15 LG305N1C-G4 Modules 4,575Wp - - - - - - - _ _ - - 350V DC, Max Current 15A Dc 1 ' ' ' for a back feed breaker 3/4" PVC out Inverter - - - - -• EMT in Serial Number 3/4" PVC G G G G G G G 2 Red #10 C+) 2 Blk #8 1 2 3 4 0 0 0 12 13 14 : 2 Blk #10 c-) 1 Grn #8 1 Grn #8 SolarEdge I MODULELG-3DS Power Optimizer — + — + — + — + — + — + — + 3/4° PVC voL 40.1V P320 _ - - _ - : A2 : 2 Blk #g vnp 32.5V - - - - - - - - _ Main Service Panel 1 Wht #8 Isc 9.93A 200A 240e Pa 1 Grn #8 Inp 9.39A National Grid ; Tnpco -.0028 Utility Meter Located on east Length 64.57' 1 String of 14 LG305N1C-G4 Modules 4,270Wp Located on North basement wall Width 39.37' 350V DC, Max Current 15A DC exterior wall Model- TBD Building,Pernit a 27 542 328 Breaker— 200A / TBDk AIR : I utility Account a TOP BOT Service Type Overhead Dis/Rec a WE f ; I Utility Meter Nunber 27 542 328 TO �-�-� Make/Model/Type CL 200 National Grid 200 I Service Detail 1 Ph 240VAC 200A Utility Grid — — — — — — — ( LEGEND SE 760OA-US Electrical Specifications ln——1— ck/RMaRO /Bi.DED CONDUCTOR Insulntlon Color Blak/RetlBlue/Braun/Drnnge/Yellor Maximum AC Output Current-32A 4/0 AL = GROUNDED CON➢ULTDR SEC I I Insulatlgn color Vhite/Grey Maximum Output Over Current Protection-40A ERJIPIENT G1aNDM CON[i t Install Manual Version 4.0 I �� I Insulation Color=Green/Bare (Id1PIDAG ELECTRM COlII.C1OR(® Insulation Color Green/Har Irreverslbly spliced EG C Installed—per NEC 250.64(C)fl)• and terninat-at GEC or GE{.unless noted otherwise GE Installed near OC discosnect per NECO200B 690.47(➢)except n condition of NECO20G8 690.47(➢) Exceptions No.l and No.2 apply. - - - - - - - - - - - - - - - - - - - " - " - - " " - - - - - - AC/OC°All 1—duct—s THVN-2 Stranded Capper unless noted otherrise PV Conductors=PV Vire Supplied by Manufacturer All Extensions Y10 PV V're Customer to clear inverter board area,provide 1" Existin 9 Loy-in-L.O.bond Eq,i GE Module Grounding Bare SoUtl °per o ar G aid t°Module/Rack conduit as a chase from attic to basement. Cn d t=Al d Con ection a 4G u less noted a Soec • LA listed Connections-All Torqued t°Spec Customer to provide internet in basement. HS to 2008 q-tict 6to 90 be lobeletl In nccortlnnce rlth NECO le advise customer about attic to basement conduit SHEET 1 of 1 chase installation. HS to verify roof dimensions, R--, A tra(t- DK 102116 pitch and azimuth. Rev'ziw. traTtr• to Rrvi.ion traitor Date • ReJsi°n Warter °ate Revkien trar<e� Date rsim trotter mu Revzon traeter 0°te Nicolas Nitti PE 100 Great Oaks Blvd. Suite I I 7 Albany,NY 12203 518.657.1029 To: Mr. Nick Poindexter 316.9-1-27.1 SOLAR-000770-2016 Hudson Solar 13 Hook Road Portuese, Beth Rhinebeck, NY 12572 271 Big Bay Road Solar Panel System (no upgrades) Date: October 19, 2016 ReE: 1610021 Subject: Portuese Residence 271 Big Bay Road Queensbury,NY 12804 Dear Mr. Poindexter, The following references the structural roof analysis of the Portuese Residence located in Queensbury, NY. Nicolas Nitti PE has been retained in order to analyze the existing roof structure for adequacy in supporting the proposed additional loading due to rooftop solar panels. The site specific loadings are as follows: Seismic Design Category B; basic Wind Speed of I I5mph; and Ground Snow Load of 50 psf, per ASCE 7-10. Based on structural analysis, it has been determined that the main gable house roof is adequate to support rooftop solar panels with a maximum loading of 4psf. The panel layout is not restricted within the specified portions of roof. Please don't hesitate to contact us with additional requests. Thank you. Nicolas Nitti PE D E G E O V E Nov 0 4 2016 of N E h, �\,pSA.A',trIt. 0 TOWN OF QUEENSB BUILDING&COD r fiSp: 07113 241 091373 G� A�OfESSIONp�' 10-19-2016 John Eibert Nicolas Nitti, P.E. Project Coordinator Owner Nicolas Nitti PE 1 100 Great Oaks Blvd.I Suite 117A 1 Albany,NY 12203 1518.657.1029 solar SolarEdge Single Phase Inverters For North America SE300OA-US J SE380OA-US / SE500OA-US / SE600OA-US SE760OA-US / SE10000A-US / SE1140OA-US i ,,,Vert v `1225 ' _ m vexa�y 'G Warr 316.9-1-27.1 SOLAR-000770-2016 Portuese, Beth 271 Big Bay Road rades Solar Panel System (no upg ) I Willi I ll Ott. mm The best choice for SolarEdge enabled systems -: Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) Small,Lightweight and easy to install on provided bracket - Built-in module-level monitoring NOV i ,16 - Internet connection through Ethernet or Wireless Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only TOWN OF BUILDINY — Pre-assembled Safety Switch for fasterinstallation - — Optional—revenue grade data,ANSI i USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHFRLANDS-ISRAtL WWW.SOIarel so I a r • 8 Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SEI0000A-US/SE1140OA-US SE3000A-US I SE380DA-US SE5000A-US SE6000A-US ISE760OA-USSE10000A-US SE11400A US OUTPUT — ..._._....._ _... _.. —.—_ _-- ------------ -_- -..----.-. 9980 @ 208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA ...... I ,,,,., ......... .50000 @2401, ... . .. . ..... ......... 5400 @ 208V 10800 @ 20BV Max.AC Power Output 3300 4150 6000 1 8350 12000 VA 10950@,40V, AC Output Voltage Min.-Nom.-Max. 1 1 V 183208 229 Vac .... . .. . .. .. . .... ... ........ ...� . . ....._. AC Output Voltage Mm Nam Max 1 211 240 264 vac AC Frequency Mm Nom Max 593 60 60.5(with Hl country setting57:.60 605 ., HZ .., 24 @ 2081, 4 Max 8 @ 2081, Continuous Output - 125 I6 25 32 47.5 A ............. . .21 @ 2a0V... ..... ...... 42 @ 34Uv GFDI Threshold __.......................................... l. . .... I ..A Utility Monitoring, slanding Protection,Country Configurable Thresholds yes Yes INPUT Maximum DC Power(STC) 4050 5100 6750 8100 10250 13,00 15350 1 W Transformer less,Ungrounded yes Max.Input Voltage 500 Vdc ........ ..– ....... _....... .. .. ............ . ....... . .... ...... ........... .._.... .. . . ....... Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc .... ....P .. .. ....... . . . ..... .�... . . . ._.... .... .. . .. i6 5 @ 2081, I I 33 @ 2081, Max Input Current' 95 13 18 23 34.5 Ado ,.. . ., ..... . .15;5,@ 2401,.. ._.. 3.05 @ 2401, . ............ Max.Input Short Circuit Current 45 Adc ......................... ................. .. ... . ..... _.. .... ... .. Reverse Polarity Protection _ _ yes .. . ... .... _... . ....... ....... .. ..... ........ Ground Fault Isolation Detection 600kn Sensitivity Mazlmum Inverter Efficiency 977 __.,. 98.2 _„ 983 95.3 ,,.98 98 98 Y . . . . . .. _. _. .... . .. ... 97.S @ 2081, 97 @ 208V CEC Weighted Efficiency 97,5 98 97S 975 97.5 % . .. ... ....... . ... . .. .. 98 @ 2401, . . . ,. n7 5 @ 240V ... _.. .. ... .... ....._.. Nighmme Power Consumption <15 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,R5232,Ethernet,ZigBee(optional) ...........................................:...............................................................,........_..........___................._.........._..,..._...... Revenue Grade Data,ANSI C12.1Optional'v' - ........................................... _... ...... _..........................I................._.. ......................_................ .'I _. Rapid Shutdown–NEC 2014690.12 Functionality enabled when SolarEdge rapid shutdown kit is installedi" STANDARD COMPLIANCE Safety ,..__..._..,.__.,.__.,_.__,UL1741,UL1699B, JI-1998,CSA 22.2 .................................................... . ._.................. .._......_........................ . ........ Grid Connection Standards IF EE 1547 ......................................_... ..........................................I........................ .....__.....___..................................;........... Emissions F FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range I 3J4"minimum/16-6 AWG 3(4"minimum/8-3 AWG OCinput condui[size J#of strings/ 3/4 minimum 14-6AW 1-2 strings/ 3/4"minimum(1-2 strings/16-6 AWG AWG rang?............... . ................._....i 14-6 AWG.,._ ..............L.......................................................... . L...................... ... .._...... Dimensions with Safety Switch 30.5 x 12.5 x 10.5( in/ 30.5x12.5 x7.2/775x 315x184 775x 315 x 260 i mm Weight with Safety Switch 7 51.2/232 I 547/24.7 1 88 4/401 Ib/kg .. .... . .. . . ..... . .. .... .. .._ ......... . ...... . ..... Natural convection Cooling Natural Convection and internal Fans(user replaceable) fan(user replaceable) Noise ,,, <25 � it � ..<50_._ � . . d8A .. in-M. .. . . . ... .p ..'.•. ....... . .. .. ... . ...... .r. .... .. .. .. ... ...... .... Min.-Max.Operating Temperature Ran a -13 to+140/-25 to+60(-40 to+60 version available' ) -F/•C ......8....................................:.................................................... ......................................................................i........... Protection Rating NEMA 3R ........................................... ........................................................................................._._.._.................................... ni A b.mne,iono.,ai:e Le an Please m,nece inverter will its ih ilree a chem Aav be used;fluenur7wowinWtmnzn OAtlUhe r2NMrend. i'i Revenue grade inverter:PIN SEv,ixA-U5000NNRE Ifor Jfi00W mwtle[5E9GOOA U5001NNR31. 40 iersion own kit P/N:SUSG*3 R56g3. 30 version P/N:SExcRvbU5000NNUi(for 9600W InverleeSE]600A-U500]NN W I. iF r romSPECRoHS f�l Sn,,plge In,,Ai lightco,ved.SOLAREDGE.this Solpr5il log,OPTIMIZED BY SOLAREDGE • . • (9 LG Life's Good i LG NeON z EM,Mm LG's new module,Ne0Nma 2,adopts Cello technology.Cello I technology replaces 3 busbars with 12 thin wires to enhance �T1 ,vWno,ren pnooucr power output and reliability.NeONni 2 demonstrates LG's p E C I V us , 60 cell efforts to increase customer's values beyond efficiency.It ` E "a ntertek features enhanced warranty,durability,performance under real environment,and aesthetic design suitable for roofs. Enhanced Performance Warranty •f High Power Output LG Ne0Nr"2 has an enhanced performance Warranty. Compared with previous models,the LG Ne0Nmv 2 The annual degradation has fallen from-0.7%/yr to has been designed to significantly enhance its output -0.6%/yr.Even after 25 years,the cell guarantees 2.4%p efficiency,thereby making it efficient even in limited space. more output than the previous NeONT"modules. ?g`'''..` Aesthetic Roof ® Outstanding Durability ------------= —_ LG NeONTM 2 has been designed with aesthetics in mind; With its newly reinforced frame design,LG has extended Eo thinner wires that appear all black at a distance.The the warranty of the NeONT'2 for an additional 2 years. product may increase the value of a property with its Additionally,LG NeONTM 2 can endure a front load up to modern design. 6000 Pa,and a rear load up to 5400 Pao Better Performance on a Sunny Day Double-Sided Cell Structure eay LG NeONTM 2 now performs better on sunny days[hanks t]!!!!!!f!!V The rear of the cell used in LG NeOM"2 will contribute to to its improved temperature coeffic envy. generation,just like the front;the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics tG Electronics is a global player who has been committed to eepbrdng its capacity,based on solar energy busness as its future growth engine we embarked on a solar energy source research program in 1585,supported by LG Group's rirh experience in s eri.,meducmc LCD,chemistry,and materials industry.We.tucressfully released the first Moan X°sines to the market in 2010,which were exported to 32 countries in cs following 2 years,nherea@ec In 2013,Node-(previeudy known as Mono Xa ri won"Intersnlar Award';which proved LG Is the leader of m ewavon in the Industry. LG NeON"2 Mechanical Properties Electrical Properties(STC*) Cells6 x 10 305 W Cell Vendor@, MPP Voltage(Vmpp) 325 _-.__ .-._._.- _---_- __..-_____ -.-..._— Cell Type Mu w ysraline/N type MPP Current(Impp) 9.39 Cell Dimensions 156.75 x 156.75 inm/6 x 6 inch Open Circuit Voltage(Voc) 40 ........ .....'------'_ .......... ."__._- -'--....... ..-.-....."-'-- »of Busbar 12(M dt VVIre Bill 0 short circuit Current(Isc) 993 Dimensions(L x W x H) 1640 x 1000 x 40 mm Module Efficiency(%) 186 6457 x3937x1 S7inch _ ._... .. . . Operating Temperature('C) ... -40.-._9_0 FutLd--_- ___-____ -____ l _ _ _ _- __ ----------- —------ rum 60 Maximum System Voltage(V) 1000 Rear Load 5400 Pal 113 psf 0 Maximum Series Fuse Rating(A) 20 __ 11;5.._.__. -.-.-.-. .................. . ___-.___- .-.-.-_-- Weight 170105 ky/37.4E 3111Is Power Tot erunce(%) 0--3 Connector Type MCA,MCA Compatible,IP67 >stc d mo-a/ ma+ r p-. x. 25¢..m 'Tbe CiodIttyt 'd yL 4. t' kanJ ab aAre>J;creCon. Junction Box iP67 with35v?ass es Fes;, 2.0% Length of Cables 2x 1000 mm 12 x 3937 inch Glassigh ransmission Tempered Glass_ _ is _.-.--H-. Electrical Properties(NOCT ) Frame .Anod.l Aluminum 305 W Certifications and Warranty Maximum Power(Pmpp) 223 MPP Voltage(Vmpp) 29.7 Certifications(in Progress) IEC S < 5 FC 61 7.x0 /2 -��,�_�---�— g ) ...�l iO3 - MPP Current(Impp) 749 150 9001.IEC 6271 fi(Ar moria?es), Open Cmcurt Voltage(Voc) 37.1------- IEC61JC1(W''Mist Ca,rosion:rest)..__ Short Circuit Current(Isc) 5.01 Module Flre Performance .Type 2(UL 1/1.03) •mo< -.,,,�m:,oe a:.,yc Cell :.m:e + '.nrea�c-�'m a .>e„�.ar r.z.: ' y<e n,r; Product Warranty 12 years 0 Output warranty of Phil Linear warranty" Dimensions(mm/in) (messurement Tolerance m 3%) - LJ, Temperature Coefficients NOCT 46 t 3PmPP -0.38 !C C _..___ .. . . ......- .. ----- .................. .,a.. y __ Voc - .-0.28%/"C -,ex .:... 1-1 Isc 003%/"C — Characteristic Curves r...�,..., e iaaaw C�•�.�--- BUOIY d r ms p cow 9 sx Ico: ssm .cw t=m 2..a; 11w ria .s m':„w=rn .. :a -........ ..__ _._ _ rM. r..a<:.....;t; 1 25 x 'e T 'The[s.ncet `re.nN .e 4..f,Fe_. .nt tly AI!`A hole.: Noah Ame ea ,,la Besrl Team I Produce pecrfcatriirr are su l "t change without notice. LG y��y LC I tar -LISA Inc -COC f E9 04'r En fifes G.M OM Sylva Ace Erclewond Cliff,,M 07632 t..aiK Cil C�2 �5-G ENctrurl Al rich,,reserned. win hr B.,Life C.C,.it 1 r �Iq mm Ot/M).015 a•w n d CO wn1 Development Office Town off Qu Oueenshury•742 Bay Rd. `? Queensbury,New York•12804 PLOT PLAN Plot Plan: Show all existing and proposed structures.Indicate the setbacks of all structures and buildings from all property lines. SIDE PROPERTY LINE T WO Z I N I III I I Z Inn I Iri Jy � O W m a r" O C < a C: C Z m KIff 1 SQUARE= FT. SIDE PROPERTY LINE Q� -C, � Ir 305 m'oCCC- arm oo