Loading...
2013-200 `�, ` TOWN OF QUEENSBURY oys742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building Sc Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY T Permit Number: P20130200 Date Issued: Friday, November 22, 2013 This is to certify that work requested to be done as shown by Permit Number P20130200 has been completed. Location: 11 BARDIN Dr Tax Map Number: 523400-316-013-0001-007-000-0000 Owner: TERI L JUCKETT Applicant: TERI L JUCKETT This structure may be occupied as a: Fireplace By Order of Town Board Garage Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or 5 F). kW. other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY ` � 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130200 Application Number: A20130200 Tax Map No: 523400-316-013-0001-007-000-0000 Permission is hereby granted to: TERI L JUCKETT For property located at: 11 BARDIN Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TERI L JUCKETT CHRISTOPHER E JUCKETT Fireplace 109 SANDFORD St Garage Attached GLENS FALLS NY 12801-0000 Single Family Dwelling $186,000.00 Total Value $186,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency • PATRICK BURKE 936 BAY Rd OUEENSBURY,NY 12804-0000 Plans&Specifications 2013-200 SFD 1st flr 1,760 sq ft; 1 gas fireplace Attached 2-car garage 576 sq ft $438.40 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, May 21,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town(Qu .'sbu/4 Tu 'a f May 21,2013 SIGNED BY ` V eta. for the Town of Queensbury. Director of Building&Code Enforcement W OFFICE USE ONLY TAX MAP NO..3 , 3 - - _' _PERMIT NO. 3-aI II Date FEES: PERMIT _RECREATION -�_ENGINEERING� 1 (If applicable) _ PRINCIPAL STRUCTE: APPLICATION FOR ZONING APPROVAL& BUILDING A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATIONPERMITR BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. IS SUBJECT TO REVIEW APPLICANT/BUILDER:_ j "Su e K e-k!- 1�C awdd''�C OWNER: /� r 1 !rC'�(' i-L e ADDRESS: i ADDRESS: 0 S S {- PHONE NOS.n( PHONE NOS.NOS. _(S F CONTACT PERSON FOR BUILDING & CODES COMPLIANCE PHONEL22222A"1/,5— LOCATION OF PROPERTY: 1' HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? IlJI YES 0 NO IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT zz ul PROJECTAPPLY 12 YOUR z0 rz cc O O co co F � O W O � mit cc --� O ~ 2 Q � � a x i-- LLP. 0 Z Q NfA 8 � OF Q: W ? I-- LL diad SINGLE FAMILY X I ' I('b se TWO-FAMILY a MULTI-FAMILY (NO.of UNITS__ TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) 1 X SW,, 5117 � g OTHER ( NO IF COMMERCIAL nP mini reTolnr ,.__... ..___ _1L{7 • ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? No ARE THERE EASEMENTS ON PROPERTY? /VD I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and _ complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed,'I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed eg, aft Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: r /1Q11— WIN- & CODES APP:OVAL ZONING APPROVAL Ig DATE DATE QUESTIONS? CALL 761.8258 OR EMAIL co estd_aueensburv.net t 3 -acr MAY I4 2013 Revised 4 14!2010 APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building&Codes Office for the issuance of a Building & Use Permit pursuant to the New York State Fire Prevention & Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. Important Note To Applicant: Rouqh-lnttand Final Inspections Are Required: Owner: C irts -4 Jerk tekeYf Installer/Builder.. pp T ke , 54-nvcmry Address: 9-4 ri eAlroV'ri- or Address: 12 IC Si ilk �0 ii-37/4- 101 Nos.: Phone Nos.: nig 26 3 S -1P150 J r Location of Property: I ( f5ogr�,w Pr. Subdivision Name: e)oiv -, e t,J CA- -Location -Location of Proposed Construction and/or Installation: L r vi KEN g M L. Contact Person for Building&Codes Compliance: CLr i f 4 1 T' -; v.ck et - Fuel Burning Applicance Wood :Coal Pellet Gas Oil Information Stove Fireplace Insert • Fireplace,factory built* X Fireplace, Masonry Furnace, (Garage Only) �* If Factory Built, Please Provide: Manufacturer Name: *ix)/ ',Dt1 Model No. L µDQ - Listed By: Number. Chimney Information . BLOCK BRICK STONE Masonry** Check One,/ TILE STEEL SIZE IN INCHES Flue Check One ✓ q`'Jl 3 DOUBLE WALL TRIPLE WALL INSULATED DIRECT CHMNEY VENT LINER Chimney Material Check Onel �/ #3( f\ {, g it** If Non-Masonry, please provide: Manufacturer Name: t'1 f 1'e,\jt d--QS Model No. t(Cdr.-teem') ADDITIONAL NOTE: CONSTRUCTION /INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION & BUILDING CODE AND/OR MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS Town of Queensbury*Community Development Office*742 Bay Road, Queensbury NY 12804 6- ar-Y3 O e Pc3, Revised 4/14/2010 Town of Queensbury Highway MAY i 4 2013 Michael F. Travis Department Highway Superintendent 742 Bay Road, Queensbury, NY 12804 Home (518) 798-0413 Office Phone: (518) 761-8211 Thomas R.Vanness Fax: (518)745-4466 Deputy Superintendent Home (518)745-0929 www. Queensburynet DRIVEWAY PERMIT Date: CP)/i3 Applicant Name: CL A( -b Te Address to be inspected: L Bn ri.„ Q.rtQa/) u) C-IS kb Return Address: WQ y 214 EI;z0.L4k Ln QtLi Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: Step 1: ( )Preliminary Approval Need: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( )15" ( )18" ( )24" ( )36" Preliminary inspections completed by: Date: Approved by Higway Supt Deputy Supt.: Upon completion, please resubmit this approved permit for a final approval. Step 2: ( ) Final Approval ( ) Rejected Date: Michael F.Travis, Highway Superintendent Thomas R. Van Ness, Deputy Highway Superintendent Town of Queensbury*Community Development Office*742 Bay Road,Queensbury NY 12804 ////' / / 16---<— / v h ` 797.ol. e i p% , / . • ° 11' 4 v 0 r. i , -o - 1-11-^ I ' (-V eill-I'I-.. .'............,...... it A8 x,335 cl.t 1 p • J )/ 1 �- . .- 1� / IS V1)• �`v°•�' k ;. • I 3f. 2°9.790 %/fn ' fi , 0 e, v; / �. ^t 7 4 l \ 1 i -- I S f / 3 5"7!'4"1°. ` u.-14: ./ °. r-i / C3 t' . . of Y. I`}3.6 Q . i !�i I II i c c • en , , % [ I. O a�. \ % uw .I `f 25,937 r50 • 15 1�' . ,.. .Cr �� �/ o 24,,972?3°/ S 1 v . N j,, ' ,;, ,>k,; , �+ / , �- I 044 ' S° s83.0 w 7 R "co-TA. • LAu95 o F Revised 4/14/2010 OFFICE USE ONLY TAX MAP NO.3 I 1.0,[3-I-'7 PERMIT NO. I 3-, k0 PERMIT FEE MAY .( 4 2013 APPROVALS: ZONING TOWN CLERK APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE `OF A VALID PERMIT. T ( (� i ry p OWNER:.f k yA 1 S —t 1 R-r; \ ecit INSTALLER: 90- d i]u -k Q_ ADDRESS: ( ( ►3 O.r elt�r. pi ADDRESS: 1 3 h V e y 1:2 i PHONE NOS. —74:1 I — g6 I U i PHONE NOS. n 2-1 1hr - LOCATION OF INSTALLATION: FD-n C 'ja.ed NO.OF COMPUTATION RESIDENCE INFORMATION: YEAR BUILT BEDROOMS X (Gallons per bedroom) = TOTAL DAILY FLOW GARBAGE GRIN/1/DSJ2 1980 or older Z x 150 = 300 ' INSTALLED? r7 1981-1991 X 130 = SPA OR HOT TUB 1992-present X 110 = INSTALLED? N® PARCEL INFORMATION: • TOPOGRAPHY: FLAT ROLLING )( STEEP SLOPE %SLOPE I SOIL NATURE SAND X LOAM CLAY OTHER I GROUNDWATER AT WHAT DEPTH? Soo 3 ✓ BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? b • DOMESTIC WATER SUPLY: MUNICIPAL X WELL, (If well:water supply horn any septic system absorption is: ft) 1 PERCOLATION TEST: RATE IS SetSrA4 r rEER aINUTE PER INCH Imps] (Test to be completed by a licensed professional engineer or architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: NI individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: !jinn) GALLON(MIN.SIZE IS 1,000 GAL)Add 250 gallons to the the septic tank for SCQ. stip- rack()each garbage grinder,spa or whirlpool tub. C `,T" ' � SYSTEM TYPE: $ABSORPTION FIELD(WITH-O.2 STONE) Total length I 2C ft Each trench 3 x "1St ❑SEEPAGE PIT(S)(WITH NO.3 STONE) - How many? `` Size? k Ii ALTERNATIVE SYSTEM Bed or other type? y„}.n( \66�i 0 r )Lr�.r.t h._r1 0 HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 13629 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury QUESTIONS? CALL 761-8256 OR EMAIL Sanitary Sewage Disposal Ordinance. codes@aueensburv.net �,— u t, _ D ,a//J3 VISIT OUR WEBSITE FOR MORE INFORMATION Signature of Person Responsible date(` www.aueersburv.net Town of Queensbury* Community Development Office*742 Bay Road, Queensbury NY 12804 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/pm Depart: AP i ) am/pm Date Inspection request received: Inspector's Initials: 1f 4i) NAME: PERMIT#: `�ZOTZ, ^2ar-D LOCATION: IN 8plzi-)tha � DATE: tl`'itt-5 TYPE OF STRUCTURE: Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant RE. -e_ta Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors \ iY-c&t< t4...r) Every level: _ Every Bedroom: J Outside every bedroom area: —Is5 ¶Z Q, fV� Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area � I I 1 1 Z\ k-3 — Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures {L Foundation insulation to floor/Sticker on Panel / s- "' Duct work sealed properly/Blower Door Test Certification (' Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade � Gas Furnace shut-off within 30 feet or within fine of site FoAr2t,"2 L Oil Furnace shut-off at entrance to fumace area Fumace/Hot Water Heater operating N1 - �] Low water shut-off boiler �, Relief Valve(s)installed/Heat Trap/Water Temp 110 � ' " L Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door!door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C/0[Temporary/Permanent] / L:1Building&Codes FormslBuilding&Codesllnspection FomrslResideMial Anal Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 626/08;Revised 12/22/10,Revised 04/13/11 Final Survey Ispection Dept. of Community Develent Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: If/7—c t ( NAME: -L ' LOCATION: 11 (j/ n FD� t!s PERMIT#: 2.or2 - Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: Craig Brown, Zoning Administrator Notes: 4U ?, 010 3 L:\SueHemingway\Building.Codes.Inspection.FORMSIFinal Survey Zoning Administrator.doc Zoning Board of Appeals - Record of Resolution Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238 FOLLOW-UP RESOLUTION July 18, 2013 TO: Patrick Burke for Juckett PROJECT FOR: Chris &Teri Juckett 936 Bay Road 11 Bardin Road Queensbury, NY 12804 Your application, after review and consideration by the Zoning Board of Appeals,was: _X_ Approved. The variance approval is valid for one (1) year from the date of approval. You may request an extension of approval before the one (1) year time frame has expired. See section 179-14-090 A copy of the resolution is attached. Additional requirements and review for this project shall include: Zoning Office _X_ See approval conditions in resolution. _X_ Submit four (4) copies of the approved plan depicting all changes and conditions of the approval as adopted by the Zoning Board of Appeals. Please bring the plans to the Zoning Office for the Zoning Administrator's signature. These plans will need to be reviewed and approved prior to issuance of a building permit. X_ Please contact Bruce Frank, Code Compliance Officer at 761-8226 within 30 days of the ZBA approval date for a pre-construction meeting before anv work is started. Page l of 2 Approval of the application means that the applicant can now apply for a Building Permit unless your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review by the Queensbury Planning Board.) Zoning Board of Appeals - Record of Resolution Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238 Continued Follow-Up Resolution Letter ZBA Meeting Date: Wed., July 17, 2013 AV 35-2013 Burke for Juckett Building Department _X_ Application for a Building Permit Application for a Certificate of Occupancy Application for necessary Sign permits, if applicable No further discretionary review is necessary at this time This office will be performing necessary inspections related to Site issues, not Building Code issues, throughout the duration of the project. Completion of and continued compliance with all details and conditions of approval are required in order to receive and maintain approvals. Since eLD l Craig Brown Zoning Administrator . CB/sh Encl. Cc: Chris &Teri Juckett Page 2 of 2 Approval of the application means that the applicant can now apply for a Building Permit unless your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review by the Queensbury Planning Board.) • Zoning Board of Appeals - Record of Resolution Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238 Steven Jackoski, Chairman Roy Urrico, Secretary TO: Patrick Burke for Juckett PROJECT FOR: Chris & Teri Juckeft 936 Bay Road 11 Bardin Road Queensbury, NY 12804 The Queensbury Zoning Board of Appeals has reviewed the following request at the below stated meeting and has resolved the following: Area Variance No. 35-2013 Patrick Burke Meeting Date: Wednesday, July 17, 2013 Approved X MOTION TO APPROVE AREA VARIANCE NO. 35-2013 PATRICK BURKE, Introduced by Michael McCabe who moved for its adoption, seconded by Ronald Kuhl: 11 Bardin Road. The applicant requests relief from an already constructed foundation for a single family home, 1760 square feet, with a 576 square foot attached garage that does not meet the required front yard setback. Our required setback is 30 feet. The proposed setback is 23.4 feet. The relief requested is 6.6 feet. Whether an undesirable change will be produced in the character of the neighborhood or a detriment to be nearby properties will be created by granting this variance. Minor impacts to the neighborhood are anticipated. Whether the benefit sought by the applicant can be achieved by some other method feasible for the applicant to pursue other than the Area Variance. Feasible alternatives appear to be limited due to the lot configuration and the existing homes on adjacent lots. Whether the requested relief is substantial. The relief requested for the front yard setback may be considered minimal relative to the Code. Whether the proposed variance will have an adverse effect or impact on the physical or environmental conditions of the neighborhood or district. Minor or no impact to Page 1 of 2 Approval of the application means that the applicant can now apply for a Building Permit unless your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review by the Queensbury Planning Board.) Zoning Board of Appeals - Record of Resolution Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8238 Continued ZBA Resolution ZBA Meeting Date: Wed., July 17, 2013 AV 35-2013, Burke for Juckett the physical or environmental conditions in the neighborhood may be anticipated. The difficulty was self-created. Duly adopted this 17th day of July, 2013, by the following vote: AYES: Mrs. Hunt, Mr. Henkel, Mr. Freer, Mr. Noonan, Mr. McCabe, Mr. Kuhl, Mr. Urrico NOES: NONE Sincerely, Steven Jackoski, Chairman Queensbury Zoning Board of Appeals SJ/sh The variance approval is valid for one (1) year from the date of approval. You may request an extension of approval before the one (1) year time frame has expired. See section 179-14-090 Final, approved plans in compliance with this variance must be submitted to the Community Development Department before any further review by the Zoning Administrator or Building & Codes personnel. Subsequent issuance of further permits, including building permits are dependent on receipt. Page 2 of 2 Approval of the application means that the applicant can now apply for a Building Permit unless your lands are Adirondack Park Jurisdictional or other approvals are necessary (such as review by the Queensbury Planning Board.) u MAP REFERENCE: BAY VIEW COURT SUBDIVISION DATED AUGUST 2, 1978 BY JOHN B. VAN DUSEN =�a LOT 15 1 HEREBY CERTIFY THAT THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS FOR WHOM THE SURVEY WAS PREPARED, AND ON THEIR BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. CERTIFIED TO: CHRISTOPHER E. & TERI JUCKETT TRUSTCO BANK, IT'S SUCCESSORS AND/OR ASSIGNS CHICAGO TITLE URANCE COMPANY ,E �.Y CERTIFIED` m M MATTHEW C 1STEVES LLS NY$ 50135 Ufl DATED: DECEMBER 71,2012 JUNE 14, 2013,, OCTOBER 23,2013, ; YY N O \\ 0 l 'jig / \ ogh' sjoFt i Y W000p PBpE v1E \ SGoNt�o fix/ \o� 610 N / N O \ O y :LOT 16 .... 30,357.47 Sq. ft./ CD 0 V IPF LOT 1 I IPF I Map of a Survey made for Christopher, E. & Teri Jucket Town of Queensbury, Warren County, New York 316.13-1-7 LOT 17 8 t Du S i I J i I LEGEND: IPF = IRON PIPE FOUND '. ICIRF = !,CAPPED IRON ROD FOUND I E`0,='':UTILITY POLE — HYDRANT it I II 'UNAUTHORIZED ALIERATON OR ADDITION TO A SURVEY JYX �/ S t e T v e s LTs� yy ry7 C $� /T P �/J $� �V a 1 i d IBJ iA i Y e J ® S. s 169 Haviland Road Queensbury, New York 12804 MAP BEARING A UC€NSED LAND SURVEYORS SEAL IS A VIOLATOR OF SECTION 7209. SUB-OIVIS'ON 2, OF THE NEW YORK STATE EDUCATOR IAM' 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARLED 1NTH AN V`OFFE T THE LAND SURVEYORS SEAL STAR BE CCfUIDERED TO BE VALID TRUE COPIES.' THISSC SCNIFY THAT IS SUR CATIONS II UI(ATED IN AG CO WAS PRAC7Ep IN ACCOUANCV WITH THE BRING COOS OF €AA TE ASSOCIATION FOR AND SURVEYORS OF IKEDALADOPTED LAND SURVEYORSL§§ D CERTI CAVOSHAD_ UN CNI-Y TO THE PERSON FOM WHOM THE SURVEY IS PREPARED, AND ON HIS HEXAD TO TPE TRE COMPANY,GOVERNMENTAL AGENCY AND LENORfiB INSTNIPQN LASTED HEREON, AND TO THE ASSIGNEES GT THE LENDING INSTNTON• 518) 792-8474 New York Lie. No. 50135 IPF LOT 1 I IPF I Map of a Survey made for Christopher, E. & Teri Jucket Town of Queensbury, Warren County, New York 316.13-1-7 LOT 17 8 t i I J i I LEGEND: IPF = IRON PIPE FOUND '. ICIRF = !,CAPPED IRON ROD FOUND I E`0,='':UTILITY POLE — HYDRANT it I II FEBRUARY 29, Scale 1'=30' S — SHEEN 4 10/23/13 FINAL UPDATE 3 6/14/13 FOUNDATION LOCATION 2 12/07/12 PROPOSED HOUSE 1 11/28/12 PROPOSED HOUSE duCKE DWG. No. 7 NO. DATE DESCRIPTION 1 OF TT C- 7006-16 r I n t Queensbury Building & Code Enforcement - Residential Final InspeC ion ` i/ r Office No. (518)761-8256 Arrive: am/pm Depart• I,I,► id am/pm Date Inspection request received: Inspector's Initials:(- NAME: 5Lt Ke.--N" PERMIT#-- , 1/.3—fes' ' LOCATION: I/ Ain.? ,('\!> DATE: f I--_u—f TYPE OF STRUCTUR : S f=JJ Comments: teyrNo NIA_ 4" Building Number Address visible from road Chimney Height/°B'Vent/Direct Vent Location I, Fresh Air Intake f 3 inch Plumbing Vent through roof minimum 18 inches ✓ Roof Complete/Exterior Finish Complete V Platform at all exterior doors ‘/ Handrail 4 or more risers ✓ Guards at stairs,decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more ✓ Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall ,f Interior/Exterior Railings 34 inches to 38 inches ✓ , Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate V Gas Valve shut-off exposed/regulator 18 inches above grade tOZ41ZakE7e Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight �/�. Safety glazing/Window in stairwells safety glazin Interior Smoke De rs/Carbon Mo�oxide odors c /// Every level: Every yedro4nff: Outside every bedroom aroma: llll ( 0 ir Inter Connected: �[ Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area / / Crawl Spaces 18 inch x 24 inch access,l sq.ft.-150 sq.ft.vents ✓ -�"'ter--rt- Bathroom Fans,if no window / Plumbing fixtures V' [ Foundation insulation to floor!Sticker on Panel N/ �— P '� « Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. /r d I c... Emergency egress below grade V GasilFurnace ut- fffft nr 30 toturaceinlineofsite �t) Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating ,!� • Low water shut-off boiler he 4r0 a ��ti�aF 7 Relief Valve(s)installed/Heat Trap/Water Temp 110 f ff Enclosed Stairs Sheetrock Underside minimum W Gypsum ✓ Basement stairs dosed rise>4 inches Garage Floor Pitched ./1/ Garage fireproofing/%hour fire door/door closer b/ _ ` Gas Logs ini Sealedl; Energy og avLightEnclosure ✓� ' ` , ^ L — Final Electrical; Energy Saving Light Bulbs 50% �'�j�� y� AFnal Survey kPlan W1�36 Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles . Flex Gas Pipe Bonding � _ t As Built Septic System/Sewer Dept. Inspection Sticker AL Site Plan /Variance required h�• OkFlay tolain issuC//Certification,rr C/O[Temporary/Permanent] fJetc-Cr—SS-10 L:1Building&Codes FormsOuilding&CodesUnspection Forns%Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 270 -/D Rough Plumbing I Insulation Inspection Report p Office No. (518) 761-8256 Date Inspection request received: 9// / o2G 4- Queensbury Building & Code Enforcement Arrive: am/pm Depart !!/ am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:6049 Wait:ait: J,4PERMIT#: d.0 3 ' a00 LOCATION: /l i34J7Lrh -,'+�C�INSPECT ON: 9 Er a-DI TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 'h inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head r 15 minutes Insulation/ esidential Check/Commercial Check or Similar Exterior Sealant o/ Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: FL- Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 j u e.sdrta- `1 Framing / Firestopping Inspection Report d Office No. (518) 761-8256 Date Inspection request received: -eN Queensbury Building & Code Enforcement Arrive: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: / NAME: S' u C P,Cf PERMIT#: 3- ) LOCATION: 11 j, a rd1 A 0 r INSPECT ON: Lr5 1� TYPE OF STRUCTURE: S Fb Fr e Y N N/A COMMENTS: Framing Ca&I Attic Access 22" x 20" minimum Jack Studs/ Headers Pod' Truss Specification Provided tip ..L6nYcl . � Bracing /Bridging \ -Co reci Joist hangers Jack Posts /Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches / Holes/Bearing Walls Metal Strapping for Notches Top Plate 11/2 (w) 16 gauge (8) 160 nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice ans water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour 1 1-047\ � Firestopping i/ )NI� . c3t�� s Penetration sealed �=-\ 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space /Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above / below grade 5.0 sf grade Design Professional Sign-off, If required Framing Firestopping Inspection_Revised_02 0513 Rough Plumbing / Insulation Inspection Report a Y Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:�tiF NAME: Eta e i i- PERMIT#: / 3 -0\vz> LOCATION: // 8QrcJrh INSPECT ON: 9 -N TYPE OF STRUCTURE: S T"-The Y N/ NIAJ aRoughiP-kgnbing /Nail Plates A/ Plumbing Vent/Vents in Place 1 IA inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent +/ Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7, 2008 tea- a-/ Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive:`zt73 am/pm 742 Bay Road, Queensbury, NY 12804 Inspect-Ws Ini ials NAME: 3 LL.C" lart-r[ PERMIT#: /3"ADZ> LOCATION: / I l•S Gan( INSPECT ON: 3 TYPE OF STRUCTURE: .5 C A N N/A COMMENTS: Attic Access 22" x 20" minimum �v Jack Studs/Headers Truss Specification Provided Vj Bracing /Bridging Joist hangers 1.0 Jack Posts/Main Beams Exterior sheeting nailed properly 12" 0.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 11 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses tI/ Anchor Bolts 6 ft. or less on center Ice ans water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space /Bedrooms 24 in. (H) • ✓ 20 in. (W) 5.7 sf above / below grade 5.0 sf grade Design Professional Sign-off, If required Framing Firestopping Inspection_Revised_02 0513 10ea a-i-cj Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive:71j17 am/pm 742 Bay Road, Queensbury, NY 12804 Inspectdfs Initials NAME: Lw c° PERMIT#: /3aOb LOCATION: / / Li Gaol INSPECT ON: 9.`-‘1-13 TYPE OF STRUCTURE: ‘5 (1 /� N N/A COMMENTS: Attc Access 22" x 20" minimum `(v Jack Studs/ Headers Truss Specification Provided V Bracing/Bridging Joist hangers � Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes /Bearing Walls Metal Strapping for Notches Top Plate 11/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses / Anchor Bolts 6 ft. or less on center Ice ans water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping y/ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space / Bedrooms 24 in. (H) 20 in. (W) • 5.7 sf above /below grade 5.0 sf grade Design Professional Sign-off, If required Framing Firestopping Inspection_Revised_02 05 13 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/am Depart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Al L-An 17-1 NAME: - + PERMIT#. Z� 2 LOCATION: 'T>N 7E, INSPECT ON: \24- TYPE OF STRUCTURE: Framing Y N NSA COMMENTS Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavq min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuiiding&Codes Forms-OLMSuitding&CodesUnspection Fcrms'Framing Restopping Impedion Report.doc Revised January 7,2008 Septic Inspection Report Office No. (518) 761-8256 Date Ins rINSPECr Queensbury Building &Code Enforcement Arrive: rt: �=742 Bay Rd., Queensbury, NY 12804 Inspector's InNAME: f C I3LOCATION: / A� I�3 RECHECK: Comments and/or diagram Soil T m Clay. Type of Wate . II Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50'+/ - Y N N/A 150'to well required if NO Absorption Field: Total length ft. Length of each trench Depth of trenches ft. Size of Stone v3 F Seepage Pits: Number A S, R U i L' Size: x Stone Size: Piping Size Type Building to tank `% Tank to Distribution Box Distribution Box to Field Pit V : t3 V-\ Opening Sealed: Y N End Cap N Inlet/Outlet Pipes&Baffles �Y N Manholes 12"or less below grade _ _ N [provide extension collar if Yes Y N Location/ Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits Conforms as per P _ _N Engineer Report an As-Buil Y N ETU Maintenance Contract Y_N provided Location of System on Property: Front Left Side Right Side Middle Front Middle Rear System Use S us: Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report 03 2910.doc Foundation Inspection Report Office No.(518)761-8256 Date Inspectio uest Queensbury Building&Code Enforcement Arrive: epart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: , NAME: _ L C 1�0 ERMIT#: / .3 — � \C_ INSPECT-ON:C�✓ 'j TYPE OF STRUCTURE: Co m n Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil po!y for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. U\Buiiding&Codes Forms\Building&Codes\Inspectlon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: U C� E PERMIT#: 3. LOCATION: j/ INSPECT ON: � TYPE OF STRUCTURE: 6 F Co m n Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection r Queensbury Building&Code Enforcement Arrive: � p Aepart: am/pm 742 Bay Rd.,Queensbury,NY 12804Inspector's Inti NAME. PERMIT#: LOCATION: ' INSPECT ON: TYPE OF STRUCTURE: Oyu Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing / for 48 hours following the placement of the concrete. L Materials for this purpose on site. l/J Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width �„6.,.,inch"4bevz ting milpoly for wet ar under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Bullding&Codes Forms\Building&Codes\Inspection Fors\Foundation Inspection Repurt.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report 64-2�,7 Ph- Office No.(518)761-8256 Date Inspection request received: 34, i Queensbury Building&Code Enforcement Arrive: am/pm Depart- am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials- 6u,6 -� 'y NAME: Vz `l PERMIT#: �' `" c LOCATION: _ I (,�'�,. ►! INSPECT ON: - l.,3 TYPE OF STRUCTURE: Columeng Y N N/A Footings n Piers , Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials AglUs-Vurpose on site. ' Foundation/ Reinforcement in Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing ' q 6 mil poly for wet areas under slab Backfill Approval (' Plumbing Under Slab . � l PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM J Foundation Inspection Report Office No.(S 18)761-8256 Date Inspection reque ecei Z> Queensbury Building&Code Enforcement Arrive: t:�Zb art: pm 742 Bay Rd.,Queensbury,NY 12804 Inspectorts Initials: NAME: 4v C �c PERMIT#: _ C)CD LOCATION: INSPECT ON: TYPE OF STRUCTURE: Com m na Y N NA ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for I 3 providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing b mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM