Loading...
2013-241 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20130241 Date Issued: Monday, September 23, 2013 This is to certify that work requested to be done as shown by Permit Number P20130241 has been completed. Location: 9 TOP OF THE WORLD Tax Map Number: 523400-252-048-0001-001-000-0000 Owner: ELIZABETH RANDALL Applicant: ELIZABETH RANDALL This structure may be occupied as a: Residential Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or oevP7 other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130241 Application Number: A20130241 Tax Map No: 523400-252-048-0001-001-000-0000 Permission is hereby granted to: ELIZABETH RANDALL For property located at: 9 TOP OF THE WORLD in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ELIZABETH RANDALL Residential Alteration $46,000.00 BEVERLY KARCH Total Value 395 LAFAYETTE Ave $46,000.00 WESTWOOD,NJ 07675-0000 Contractor or Builder's Name/Address Electrical Inspection Agency TOWPATH CONTRACTORS 743-9391 12 GEER St GLENS FALLS.NY 12801-0000 Plans&Specifications 2013 Res.Alteration 240 sq ft-dormer $60.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,June 10,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the TownQuee bury; o y, une 10,2013 71 SIGNED BY for the Town of Queensbury. Director of Building&Co e Enfo krnent Office Use Only Town of Queensbury Building & Codes Received: PRINCIPAL STRUCTURE APPLICATION " ��° fax Map ID: � � -1- 1 s,�. ; Permit No.: A permit must be obtained before beginning construction Permit Fee: $ 1 Please read: *TB resolution 86-2013(1-28-2013): $850 recreation fee for new dwelling *Rec Fee: $ units, including single-family dwellings, duplexes or two-family dwellings, multiple family Site Plan No.: dwellings, apartments, condominiums, townhouses, and/or manufactured and modular Subdivision No.: homes,but not including mobile homes. This is in addition to the permit fee. Date - _ l ''� Applicant 6 P N - FCS✓-%' Tax Map ID Address f r;L 6r4E11r1_2- SG-+ Zoning 01-1-&N S 66k_"' IV t--gj I Phone/E-mail (c'- 7 ft-- 177 -3 Property Owner P-)q" D!} /-1-- Contractor/Agent !PA-�H !O/�G%l�Ci��S. aC Address 3 R /-A F 14Address [ 02- - G>t�S?(,UaQD, 14 e) 2& 7T Phone/E-mail 'Lo 1 - F19 1 S' Phone/E-mail Building Street Address: �ht "Ce-Hoo- M%14. 12D Subdivision Name: id-7° 0 f 71MF IWRZ� Lot#: 1.1L t i x-`61 Historic Site: YesNo Estimated cost of construction: $ , cl --- Type of Construction: Check all that apply Please indicate measurements as required below: o S 3 *= 1st Floor 2nd Floor Other Total Height Z ¢ a Single Family Two-Family Multi-Family(#of units--) Townhouse ) 3 j l� �17 9� x396 f�3 5F Business Office Retail-Mercantile Factory-Industrial Attached Garages(#_) Other Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 If commercial or industrial indicate name of business Proposed use of building or addition IqyD j�d1,ctq 'po M / f` ln-rnf Source of heat(circle one) Gas Oil Propane Solar Other Fireplace-complete a separate application for"Fuel Burning Appliances&Chimneys" _Yes L-*"'N-o Are there structures not shown on plot plan? N p Are their easements on the property? NO Site Information a. Dimensions or acreage of lot b. Is this a corner lot? H/1. - c. Will the grade be changed as a result of construction: N/14 _Yes —No d. Public water or Private well P a f,G_(C, e. Sewer or Private Septic System j&4)FOZ— Value of all work to be performed(labor and materials) t i-r ct $ Declaration: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. I certify that the application,plans, and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed12,2"JDate: � FOR OFFICE USE ONLY: Operating Permit Issued: _Yes _No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT LOCATION: y r '` c<=. 'I s' DATE: C TYPE OF STRUCTURE: q o. Comments- Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors!main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Eve edroom: Outside every bedroom ea: Inter Connected: Batte backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to fumace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Y2"Gypsurn Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light ht Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 Cj._jl u)Ca in-- OU t / Insulation Inspection Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depa am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: I d PERMIT #: LOCATION: �� INSPECT ON: `�✓ �--f.,�3 TYPE OF STRUCTURE: n _ Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet l change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If Leguired unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received. Queensbury Building & Code Enforcement Arrive: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: P UVj Q-d PERMIT#: I 'yf LOCATION: �/if—/ i, a a jC1,&c�_� OI INSPECT ON: ` ._! 3 TYPE OF STRUCTURE: Wilt Y N N/A COMMENTS: Framing �r Attic Access 22" x 20" minimum Jack Studs/Headers Truss Specification Provided Bracing /Bridging Joist hangers Jack Posts/ Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1'/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice ans water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space /Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above /below grade 5.0 sf grade Design Professional Sign-off, If required Framing Firestopping Inspection—Revised-02 0513 REScheck Software Version 4.4.4 NOTICE r8/1 Compliance Certificate FOAM INSULATIONAUSTBE I� COVERED BY 15 MINUTE THERMAL BARRIER Project Title: Randall / Karch Residence . It J F E P Y Energy Code: 2010 New York Energy Conservation Location: Warren County,New York Construction Type: Single Family NOTICE Project Type: Addition Conditioned Floor Area: 0 ft2 KRAFT PAPER INSULATION Heating Degree Days: 7635 MUST BE COVERED BY Climate Zone: 6 NON-COMBUSTIBLE BARRIER Permit Date: Construction Site: Owner/Agent: Designer/Contractor: Unit 9 Lisa Randall Curtis Dybas 441 Lockhart Mountain Road 395 Lafayette Avenue 19 Deer Run Queensbury,NY 12804 Westwood,NJ 07675 Lake George,NY 12845 201 8191268 518 668 5591 Irandallgop@msn.com cdybas@yahoo.com Compliance: Compliance: 0.0%Better Than Code Maximum UA: 36 Your UA:36 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Cavity Cont. Glazing Assembly Area or R-Value R-Value or Door UA Perimeter U-Factor Ceiling 1:Cathedral Ceiling 279 30.0 0.0 9 Wall 1:Wood Frame,16"o.c. 344 21.0 0.0 - 18 Window 1:Wood Frame:Double Pane with Low-E 30 0.300 9 SHGC:0.00 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.4.4 and to comply with the mandatory requireme isted in the REScheck Inspection Checklist. NameTitle' Signature Date \F3ED ARC, 0. J A � U M Z ce 4 r � P � �i�i qqC 119�0 ��'3• THf STNIt Project Title: Randall/Karch Residence Report date: 05/23/13 Data filename: C:\Users\Owner\Documents\REScheck\Randall Residence.rck Page 1 of 6 REScheck Software Version 4.4.4 Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. 2010 New Plans Verified Field Verified York Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions Energy 103.2 ;Construction drawings and i❑Complies ' [PR1]1 documentation sufficiently {❑Does Not Comply demonstrates energy code _]Not Observable compliance for the building envelope. ❑Not Applicable 103.2, Construction drawings and ( ❑Complies 403.7 documentation sufficiently ' I ❑Does Not Comply [PR3]1 ;demonstrates energy code ❑Not Observable compliance for lighting and Lt3 P 9 9 ❑Not Applicable mechanical systems.Systems serving multiple dwelling units must i ! demonstrate compliance with the commercial code. l 403.6 Heating and cooling equipment is Heating: Heating: ❑Complies [PR2]2 sized per ACCA Manual S based on Btu/hr Btu/hr ❑Does Not Comply loads per ACCA Manual J or other ; Cooling: Cooling: ❑Not Observable approved methods. Btu/hr Btu/hr ;❑Not Applicable a ; ; Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Randall/Karch Residence Report date: 05/23/13 Data filename: C:\Users\Owner\Documents\REScheck\Randall Residence.rck Page 2 of 6 2010 New York Foundation Inspection Complies? Comments/Assumptions Energy 303.2.1 Exposed foundation insulation ❑Complies [F011]2 protection. :❑Does Not Comply; Ley '❑Not Observable i ❑Not Applicable 403.8 ;Snow melt controls. ;❑Complies [F612]2 i ❑Does Not Comply { :❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Randall/Karch Residence Report date: 05/23/13 Data filename: C:\Users\Owner\Documents\REScheck\Randall Residence.rck Page 3 of 6 2010 New Plans Verified Field Verified York Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions Energy 402.4.4 ;Fenestration that is not site built is :',❑Complies [FR20]' listed and labeled as meeting rt❑Does Not Comply ;AAMA/WDMA/CSA 101/I.S.2/A440 or ❑Not Observable has infiltration rates per NFRC 400 1EINot Applicable that do not exceed code limits. i 402.4.5 (IC-rated recessed lighting fixtures EComplies ' [FR16]2 sealed at housing/interior finish and j ;❑Does Not Comply Ck; labeled to indicate&It;=2.0 cfm 7[]Not Observable i leakage at 75 Pa. [ ❑Not Applicable 403.2.1 ;Supply ducts in attics are insulated to R- R- ;❑Complies [FR12]1 I R-8.All other ducts in unconditioned R- R- ❑Does Not Comply ;spaces or outside the building ;❑Not Observable envelope are insulated to R-6.Not ❑Not Applicable applicable if all systems are ductless. 403.2.2 ;All joints and seams of air ducts,air ';❑Complies ; [FR13]1 handlers,filter boxes,and building ;❑Does Not Comply cavities used as return ducts are ❑Not Observable sealed. i ❑Not Applicable 40312.3 Building cavities are not used as ducts j ,' ', i;❑Complies [FR15]3 or plenums. i (❑Does Not Comply QNot Observable �.. ❑Not Applicable 403.3 HVAC piping conveying fluids above R- R- ;❑Complies [FR17]2 i 105 OF or chilled fluids below 55 OF ❑Does Not Comply t� are insulated to R-3. ; ;❑Not Observable ❑Not Applicable 403.4 1 Circulating service hot water pipes are R- R- ', Complies [FR18]2 i insulated to R-2. ❑Does Not Comply f ' ` ❑Not Observable ;❑Not Applicable 403.5 Automatic or gravity dampers are a❑Complies ' [FR19]2 installed on all outdoor air intakes and c )❑Does Not Comply t� iexhausts. = ;❑Not Observable I f El Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Randall/Karch Residence Report date: 05/23/13 Data filename: C:\Users\Owner\Documents\REScheck\Randall Residence.rck Page 4 of 6 2010 New York Insulation Inspection Complies? Comments/Assumptions Energy 303.1 :All installed insulation labeled or ;❑Complies [IN13]2 installed R-values provided. �❑Does Not Comply :❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Randall/Karch Residence Report date: 05/23/13 Data filename: C:\Users\Owner\Documents\REScheck\Randall Residence.rck Page 5 of 6 2010 New -Plans Verified Field Verified; York 'Final Inspection,Provisions Value Complies? Comments/Assumptions Energy , .Value • r 402.4.2, ;Building envelope tightness verified ACH 50= ACH 50= ;❑Complies 402.4.2.1 by blower door test result of&lt;7 ACH ❑Does Not Comply [F[17]' ;at 50 Pa.This requirement may ;❑Not Observable L ;instead be met via visual inspection, ;❑Not Applicable in which case verification may need to occur during Insulation Inspection. 402.4.3 Wood-burning fireplaces have I E]Complies [F]8]2 gasketed doors and outdoor i s❑Does Not Comply ;combustion air. ❑Not Observable l❑Not Applicable 403.2.2 Duct tightness via post-construction cfm cfm ;❑Complies [1=I4]� with maximum leakage of 8 cfm to ;❑Does Not Comply & ;outdoors,or 12 cfm across systems. ;❑Not Observable ; For rough-in tests,verification may :❑Not Applicable need to occur during Framing ; Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1 Programmable thermostats installed +. '❑Complies [Fl9]2, ion forced air furnaces. ; ` ❑Does Not Comply; L ❑Not Observable I h r:.l❑Not Applicable 403.1.2 Heat pump thermostat installed on I - ? UComplies [F110]2 i heat pumps. f :.. ...,:,,.$ ,,; i❑Does Not Comply; i ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water systems l❑Complies I [FI11]2 have automatic or accessible manual "" I❑Does Not Comply; Q. controls. I❑Not Observable ' I I ]EINot Applicable 403.9.1 I Readily accessible switch on heaters =''.' = .'•-i❑Complies [F112]3 for swimming pools. ;;, 'J' ':`;•, ; -]❑Does Not Comply: } ]❑Not Observable I; I❑Not Applicable 403.6.2 Timer switches on pool heaters and si6 '`. ' ,:1EIComplies [FI1'9]3 pumps are present. 1 " I❑Does Not Comply ❑Not Observable ; , t•: ;" ❑Not Applicable ; 403.9.3 Heated swimming pools have a cover. :,' )❑Complies [FI20]3 Covers on pools heated over 90°F k : ;, :' ❑Does Not Comply j are insulated to R-12. `l s• ❑Not Observable ; L&>:;• :; ;❑Not Applicable 401:3, . Compliance certificate posted. 3 J❑Complies [FI7]2 C i❑Does Not Comply I I❑Not Observable I ❑Not Applicable 303.3 Manufacturer manuals for mechanical i 1❑Complies [FI18]3 and water heating equipment have }❑Does Not Comply: been provided. - i❑Not Observable ; ;❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Randall/Karch Residence Report date: 05/23/13 Data filename: C:\Users\Owner\Documents\REScheck\Randall Residence.rck Page 6 of 6 i � l 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation . Wall 21.00 Floor 0.00 Ceiling/Roof 30.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door CoolingHeating & Heating System: Cooling System: Water Heater:__________` Flame: Date: Comments: • r WINDOW SCHEDULE CALCULATION SHEET •- JOB SITE ADDRESS: DATE: — OWNER: .l APPLICATION NO.: Window#or Letter Window Manuf. Window Unit or Stock# Rough Rough Sq.Ft.Vent Sq.ft.egress I Clear opening Clear opening Special hardware or on Plan Name Model Type Call size Opening Width Opening clear opening width in inches height in instructions Height inches l D AL cgsi rmkl o"-1 3/ 0 3/ `/ 35 (tea 17"w � Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 NATURAL LIGHT, VENTILATION, AND EMERGENCY EGRESS REQUIREMENTS CALCULATION SHEET JOB SITE ADDRESS: kOCIL14602 M704 - U. UN,j -#c, DATE: D Lc — D OWNER: l,.d S A P40N b A-" APPLICATION NO.: � NATURAL LIGHT, VENTILATION, AND EMERGENCY EGRESS REQUIREMENTS Habitable Room Area of Room Required light Actual light square footage Required ventilation Actual Ventilation Square Footage Square Foot Opening for Egress Remarks In Square Feet 8%of room area 4%of room area 13-'-a"X17`9" 1`f, I 0?_0 it 173co Town of Queensbury Building&Codes Principal Structure Packet 518-761-8256 -4—J 7 __.�.._ � __:.�-_ - ._.�__.-�_•--_�.__...�.__���...�. Cat��!'�t r � r� ,,� f - fir T t- W6 �' - ® - �J• sn - t i rT av c o -97 - F _ tpi :Zo, 4 i