BOTH-000228-2015TOWN OF QUEENSBURY
OL 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: BOTH-000228-2015
Tax Map No: 278.-1-18
Permission is hereby granted to: John Hughes,Richard Hughes
For property located at: 1 ROCKLAND DR
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: JH Land Development Other Accessory Structure(s) 62,800.00
Owner Address: 321 State Rte 149 Total Value 62,800.00
Lake George,NY 12845
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
Bathhouse 912 sq.ft.
AV 7-2015&SP 10-2015
50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,November 3,2017
If a longer period is required an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbu fore yexp' tion
JJJdateDatedattheTownofmensb4onymr9,2015
SIGNED BY:
a
for the Town of Queensbury.
Director of Building&Code Enforcement
y r
PRINCIPAL STRUCTURE APPLICATION Office Use Onlv
DATE Received
Tax Map ID
TAxMAP ID 278.-1-18 Permit No.
Permit Fee
ZONING RR-3A Rec Fee
Site Plan#
HISTORIC SITE Yes X No Subdivision#
SUBDIVISION NAME Lot#
TOWN BD. RESOLUTION 86-2013: $850 RECREATION FEE FOR NEW DWELLING UNITS, INCLUDING SINGLE FAMILY DWELLINGS,
DUPLEXES OR TWO FAMILY DWELLINGS, MULTIPLE FAMILY DWELLINGS, APARTMENTS, CONDOMINIUMS, TOWNHOUSES, AND/OR
MANUFACTURED&MODULAR HOMES,BUT NOT MOBILE HOMES. THIS IS IN ADDITION TO THE PERMIT FEE.
APPLICANT LEDGEVIEW VILLAGE & RV PARR OWNER J.H. LAND DEVELOPMENT, LLC
ADDRESS 321 STATE ROUTE 149 ADDRESS 321 STATE ROUTE 149
QUEENSBURY NY 12804 QUEENSBURY NY 128804
PHONE/E-MAIL PHONE/E-MAIL cS2—_ W-q9-,
CONTRACTOR COST OF CONSTRUCTION(ESTIMATED): $
ADDRESS: BUILDING ADDRESS: Q-OGL,AO,yid.t y iVRJ
PHONE/E-MAIL
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE:Otai HU&tA PHONE _776\-L"I'!1
9kc-V\PeD LV-37
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
New Addition Alteration 1 floor sq.ft. 2nd floor sq.ft. Total sq.ft. I Height
Single Family
Two-Family
Multi-Family
of units_)
Townhouse
Business Office
Retail - Mercantile
Factory- Industrial
Attached Garage
of
OtherGQrx_920 SQ. FT. 920 SQ. FT. 16'
1
Town of Queensbury Building&Codes Principal Structure Application July 2014
If commercial or industrial indicate name of business LEDGEVIEW VILLAGE & RV PARR
Proposed use of building or addition CENTRAL FACILITIES
Source of heat (circle one) N/A Gas Oil Propane Solar Other
Fireplace: complete a separate application for Fuel Burning Appliances &
Chimneys
Are there structures not shown on plot plan?
Are there easements on the property?
Site Information
a. Dimensions or acreage of lot SEE PLANS
b. Is this a corner lot?No
c. Will the grade be changed as a result of construction x Yes No
d. Public water or Private well PRIVATE WATER SYSTEM
e. Sewer or Private Septic System PRIVATE SEPTIC SYSTEM
Value of all work to be performed (labor or materials)
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed
within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement/ description of
the work proposed, that all work will be performed in accordance with the NY State Building Codes, local
building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy.
5. 1 also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above: PRINT NAME:eS DATE I l- 9- 15
SIGNATURE: LQo DATE /L I-
FOR OFFICE USE ONLY
Operating Permit Issued: Yes _No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
2
Town of Queensbury Building&Codes Principal Structure Application July 2014
Foundation Inspection Report
Office No. (518)761-8256 Date Insp
ection c v d:
Queensbury Building&Code Enforcement Arrive: Depart: am/pm
742 Bay Rd.,Queensbury,NY. 12804 InspectoNAME: ^ #: SO 1 lg b
LOCATION: UasAC3-ymwyky.pT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A ,yrti
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing'
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building &Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/9/2014
Rough Plumbing 1 Insulation Inspection Report
Inspection request received
Name Inspected on
Location ����� Arrive
Permit No. bO1"1,k _ aa-0 2 _29 15 Inspector's Initials
Type of Structure
�y.
t
COMMENTS
Y / NA
bing under slab 4 ll
Rough Plumbing/Nail Plates CS lri l.l.._
Plumbing Vent/Vents in Place /
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Dr n%Vent
Air Head
P.S.I.or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S:I for 15 minutes
Insulation/Residential Check/Commercial Check
Window Sealing
Tyvek or Similar Exterior Sealant
Proper Vent,Attic Vent
Door/Window Sealed(No Insulation)
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
Blower Door Test
Air Sealing
Town of Queensbury Building & Code Enforcement Office No. (518)761-8256
INSPECTION WORKSHEET (BINS-008250-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
BOTH-000228-2015PermitCaseNumber:Case Module:
Tue Nov 27, 2018Partial PassInspectionDate:Inspection Status:
John O'BrienCommercial Final InspectionInspector:Inspection Type:
1 ROCKLAND DR278.-1-18JobAddress:Parcel Number:
LAKE GEORGE, 12845
Contact TypeCompany NameName
Primary OwnerJH Land Development
Granted PermissionHughes, John
Granted PermissionHughes, Richard
ApplicantLedgeview Village & RV Park
Checklist ItemPassedComments
AtticAccess 30x20x30 (h)YESProvide anattic access 22" x30" inCorridor where 1/2"
sheetrock tobeinstalled over kraft insulation.
H/C Bathroom Grab Bars /Sinks/Toilets/MirrorsYES- Add 36" garb bar onback wallbehind handicapped toilet.
See attached detail.
Site Plan Variance requiredNO- Site Inspection byBruce Frank forplanning and zoning sign
off.
Engineer or Architect ApprovalNO- Submit Final Approval Letter from Tom Hutchins the
engineer.
Nov 27, 2018Page (1)
INSPECTION WORKSHEET (BINS-008250-2018)
Checklist ItemPassedComments
OK to Issue C/ONO11/14/18 Final Inspection Not Approved
Remaining Items:
Provide anattic access 22" x30" inCorridor where 1/2"
sheetrock tobeinstalled over kraft insulation.
Add 36" garb bar onback wallbehind handicapped toilet.
See attached detail.
Submit Final Approval Letter from Tom Hutchins the
engineer.
Install Truss IDSignage in2locations. See attached photos
forlocations.
Install 1/2" sheetrock onceiling ofcorridor covering kraft
faced insulation.
Site Inspection byBruce Frank forplanning and zoning sign
off.
11/27/18Final Inspection NotApproved
Remaining Items:
Submit Final Approval Letter from Tom Hutchins the
engineer.
Site Inspection byBruce Frank forplanning and zoning sign
off.
O'Brien, John (Inspector)
Nov 27, 2018Page (2)
INSPECTION WORKSHEET (BINS-007877-2018)
Town ofQueensbury - Building andCodes - FireMarshal
742BayRoad - (518) 761-8256 Building (518) 761-8206 FireMarshal
Case Number:BOTH-000228-2015Case Module:Permit
Inspection Date:11/14/2018Inspection Status:Failed
Inspector:John O'BrienInspection Type:Commercial Final Inspection
Job Address:1 ROCKLAND DRParcel Number:278.-1-18
LAKE GEORGE, 12845
Contact TypeCompany NameName
ApplicantLedgeview Village & RV Park\[Ledgeview Village & RVPark\] ,
Granted PermissionHughes, John
Primary OwnerJH Land Development\[JHLand Development\] ,
Granted PermissionHughes, Richard
Checklist ItemPassedComments
Chimney / BVent / Direct Vent LocationYES
Plumbing Vent Through Roof/Roof completeYES
Ext Finish /Grade Complete/6 in 10ft orEquivalentYES
Doors 36inch wLever Hand Panic Hardware, if reqYES
ExitsAtGrade OrPlatform 36 (w) x44 (l)YES
GasShut-offExposed & Regulator (18) Above GradeYES
Floor Bathroom Watertight Other Floors OkayYES
Relief Valve ,Heat Trap/Water Temp 110 deg orlessYES
Gas Furnace Shut OffYES
AtticAccess 30x20 x30 (h)NOProvide anattic access 22" x30" inCorridor where 1/2"
sheetrock tobeinstalled overkraft insulation.
H/CBathroom Grab Bars /Sinks/Toilets/MirrorsNO- Add36" garb baronback wallbehind handicapped
toilet.
See attached detail.
Handicapped Bath/Parking Lot SignageYES
Lowflowtoilet 1.3gal/flushingcycle -YES
showerhead/faucet
Universal Symbol ofAccess displayed - onall H/CYES
signs
Public Toilet Room Handicapped AccessibleYES
Final Electrical / Flex Gas Piping BondedYES
Nov 14, 2018Page (1)
INSPECTION WORKSHEET (BINS-007877-2018)
Checklist ItemPassedComments
Site Plan Variance requiredNO- SiteInspection byBruce Frank forplanning andzoning
sign off.
As-built Septic System Layout RequiredYES
Bldg Access All Sides 20ft Drivable SurfaceYES
Engineer or Architect ApprovalNO- Submit Final Approval Letterfrom Tom Hutchinsthe
engineer.
OK to Issue Temporary C/ONO
OK to Issue C/ONO11/14/18 Final Inspection Not Approved
Remaining Items:
Provide anatticaccess 22" x30" in Corridor where 1/2"
sheetrock tobeinstalled overkraft insulation.
Add36" garb baronback wallbehind handicapped
toilet.
See attached detail.
Submit Final Approval Letterfrom Tom Hutchinsthe
engineer.
Install Truss IDSignage in 2locations. Seeattached
photos forlocations.
Install 1/2" sheetrock onceiling ofcorridor covering
kraft faced insulation.
SiteInspection byBruce Frank forplanning andzoning
sign off.
O'Brien, John (Inspector)
Nov 14, 2018Page (2)
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No...4.....
J -..
h&A.1JCert. NO
p 4,4'9 3-0/C/uutt-in Card No.....................................
Owner...../ .i— . .r ..Y... jr(. ....../ ..c...af ...../....,fT'Ifr.'`......................................................
3..........7...................
Installation Consisting of..: .. "T 7... /t'.f.T ". .. 1 f'^F.r...................
l Tzy ....,
Installed By...4.`....b c..1.4r......f,AJ6 .......................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making i tions at any time, and if its
rules are violated,the Company shall have the right-to r o his ce ific .
Date.......f(:...:L./..` /.............. INSPECTOR...... ................./
Meni.r N.RP.A.,I.A.E.1.
169 Haviland Road
Queensbury,NY 12804
Hutchins Engineering Faria eecaoed
Soy -000228-201S
November 27,2019
Mr.John O'Brien
Town of Queensbury
742 Bay Road
Queensbury NY 12804
Re:John Hughes,Ledgeview RV Park
Central Facilities Building
321 State Route 149,Tax Map ID:278.-1-18
Dear Mr.O'Brien:
‘As we have discussed,this office prepared plans for central facilities building recently constructed
at the referenced facility.Representatives of our office visited the site numerous times during
construction,and it is my opinion that the building has been constructed in general conformance
with the plans approved by your office.
Should you wish to discuss,please call.
Best Regards
on MOG.Thomas Hutchins,P.E.
Co:Ledgeview
6.Thomas Hutchins,PE.thutchins@hutchinsengineering.com