Loading...
2013-575 TOWN OF QUEENSBURY eta. 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 ItioN Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20130575 Application Number: A20130575 Tax Map No: 523400-227-018-0001-030-000-0000 Permission is hereby granted to: GARY ZERVAS For property located at: 85 HANNEFORD Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ADIRONDACK MIN RIDGE EST., Test Pit/Perc Test Review 136 STONE SCHOOLHOUSE Rd Total Value LAKE GEORGE NY 12845-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2013-575 PERC TEST complete. - See BP 2014-104 SFD $200.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,December 16,2014 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Monday, December 16, 2013 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Town of Queensbury• Building&Codes Enforcement Office•742 Bay Road• Queensbury, NY 12804 DEEP HOLE/PERC TEST VZ 2p1'3 Request for Town Engineer Review Property Owner: '7ev-7 Z - '-v.`t 5 Phone: 5b " "' 86 < <( Property Owner's 1� Address: f3b S *tet _QV)c+I114-iSt' 1«�. L 6: , /1/y / eif Location of Test: /33 ��<� -i r� . Tax ID#: �� t I g -1-30 *Applicant's Engineer: G .5 v C_� Phone: 66- 8— 4i4 �E Applicant's Agent: DQv i•) Phone: SS r 715/ Additional Notes: 1. Reason for Request? New Septic System Pc1 Replacement Septic System Failed Septic System Subdivision Site Plan Review 2.Are Wetlands present? YES Y I NO UNKNOWN *Note: Applicant is required to engage an engineer for design and testing of the system. The Town Engineer's responsibility is to witness system testing only. PLOT PLAN: Plot plan, to scale, to be submitted with application FEE SCHEDULE: a. $ 200 Flat Fee Date Paid: Check No.: b. OR Fee to be determined during To Be Determined: Site Plan /Subdivision review process SIGNATURE: In carrying out the provisions of Article IV, the Local Board of Health or the enforcement officer may engage the services of a qualified professional consultant for expert review and recommendation arising from the carrying out of the provisions of Art. IV, including but not limited to the review of plans, specifications and reports, attendance at inspections, dye tests, deep hole test pits, septic related deep hole and percolation tests, system installations, and any other aspect of any matter contained in this Art. IV, and any costs incurred in such review shall be paid to the Town by the owner of the property before any approval can be granted under this Art. IV shall become effective within 30 days of presentment of an invoice for same, whichever is sooner. Such costs shall not exceed $1,500 without prior written notice to the party to be charged with same. My signature below indicates I have thoroughly read and understand the instructions, agree to the submission requirements and have completed the application. I also fully understand that additional engineering fees may be necessary per Town of Queensbury Local Law 136-14D. SIGNATURE OF APPLICANT: Date: SIGNATURE OF AGENT: / - Date: (2/164 Original (B&C File) Canary(Planning) Pink(Applicant) Gold (Town Clerk) j5/75 THE North Country Office C /J Onn 375 Bay Road, Queensbury, NY 12804 P: (518) 812-0513 F: (518) 812-2205 COMPANIES www.chazencompanies.com Engineers Hudson Valley Office (845)454-3980 Environmental Professionals Capital District Office (518)273-0055 Land Surveyors Landscape Architects Planners December 17, 2013 Dave Hatin, Director, Building and Codes Town of Queensbury 742 Bay Road Queensbury, New York 12804 Re: Soil Testing Verification 85 Hanneford Road Queensbury, NY 12804 Dear Mr. Hatin: As requested, Chazen has completed an onsite soil testing witnessing for the above referenced location on December 17, 2013, in regards to subsurface soils conditions for a proposed septic system design. The testing was performed by Charlie Maine of Queensbury for D.L. Dickinson Associates.The proposed system is intended to replace the existing system on the property. One test hole and two percolation tests were performed approximately 100 feet to the east of the existing house. The initial test hole (TP-1) was performed in the vicinity of the existing septic system. The subsurface soil was comprised of the following: 0"-8" Topsoil 8"-14" Loamy Sand (mottling observed @ 14") 14"-72" Fine Sand Stabilized percolation rate,test#1: 3m10s/in. Stabilized percolation rate,test#2: 3m15s/in. If you have any questions or require additional information please do not hesitate to call me at (518) 824-1926. Sincerely, Sean M. Doty, P.E., LEED AP Senior Project Engineer cc: File Chazen Engineering,Land Surveying&Landscape Architecture Co.,P.C. Chazen Environmental Services,Inc. The Chazen Companies, Inc.