BOTH-000339-2015 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
a
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: BOTH-000339-2015 Date Issued: Wednesday, January 20, 2016
This is to certify that work requested to be done as shown by Permit Number BOTH-000339-2015
has been completed.
Tax Map Number: 290.17-1-15
Location: 26 MASTERS CMN SOUTH South
Owner: MICHAEL HEALEY,Eileen Healey
Applicant: MICHAEL HEALEY
This structure may be occupied as a: Enclosed porch 238 s.f.
By Order of Town Board
TOWN OF QUEEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the � _ f/
property owner of the responsibility for compliance with Site Plan, ���yyy///FFF"' W A�
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
QMW Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: BOTH-000339-2015 REVISE D
Tax Map No: 290.17-1-15 Pe 4QAy — St`5
Permission is hereby panted to: Eileen Healey
For property located at: 26 MASTERS CMN SOUTH South
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: MICHAEL HEALEY Porch-3 Season,Covered,Enclosed $5,000.00
Owner Address: 26 Masters Common Total Value $5,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
Enclosed porch 238 s.f.
PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday,October 25,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town 9EQere sbury; Th say ctober 30,2014
SIGNED BY: \( for the Town of Queensbury.
Director of Building&Code nforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20140513 Application Number: A20140513
Tax Map No: 523400-290-017-0001-015-000-0000
Permission is hereby granted to: MICHAEL&EILEEN HEALEY
For property located at: 26 MASTERS COMMON SOUTH
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tvne of Construction Value
Owner Address: MICHAEL&EILEEN HEALEY Porch $5,000.00
26 MASTERS COMMON SOUTH Total value
QUEENSBURY NY 12804-0000 $5,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2014-513
PORCH 238 sq.ft. (enclose existing)
$50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, October 30,2015
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the TownQue sbury �j Th r d ober 30,2014
SIGNED BY �VI for the Town of Queensbury.
`
Director of Building& Code Enforcement
ACCESSORY STRUCTURE APPLICATION Office Use Only
Received
DATE y– 20 y Tax Map ID
TAxMAPfD Permit No.
ZONING Permit Fee
Rec Fee
HisTDRIC SITE —Yes _No Approvals
SUBDIVISION NAME Lot#
APPLICANT AIcJ AZL G' NFAL=Y OWNER
ADDRESS (�_omygm) SO- ADDRESS
�GCK
5;V$L?U4Y .t/Y /'$Dy
PHONE .366- 6s64, PHONE
CONTRACCOST OF CONSTRUCTION(ESTIMATED)• $ SOOO
ADDRESS: SAKt`L — BUILDINGADDRESs:
PHONE: `/ p
CONTACTPERSONFORBUILDING&CODES COMPLIANCE ��� /4e4L�c' PHONE
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
Boathouse 1;'floor sq.ft. 2nd floor sq.ft. Total sq.ft. Height
Boathouse with Sundeck
Deck
Detached Garage(#of cars_)
Dock
Pole Barn
Porch•open
Porch–3 season,Covered,Enclosed /D
Shed
Other Accessory Structure(s)
"Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone
DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the
application, plans and supporting materials are a true &complete statement description of the work proposed,that all work will be
performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local
zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy. I also understand that 1/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
✓I have read and agree to the above: Print Name: fe Date:
Signature: Date: /D'
1
Town of Queensbury Building&Codes Accessory Structure Application July 2014
ACCESSORY STRUCTURE APPLICATION (Requirements, Notes, Changes)
REQUIREMENTS:
1. Two(2)sets of the following documentation with the apolication and fee:
a) Plot plan drawn to scale with the use of a survey map, if possible (40 scale=40 feet)
b) Indicate proposed structure(s), showing setback dimensions from all surveyed property lines
c) Show location of all existing structure(s) on the property
d) Show location of water supply (well or water lines)
e) Show location and configuration of septic disposal system or sewer line.
2. Structural drawings to include: Floor plan; Foundation plan, Cross Sections, Elevations
3. Registered Architect or Engineer's stamp, signed &sealed for residential additions/alterations and any commercial
construction costs over$20,000
NOTES:
1. A permit must be obtained before beginning construction
2. This permit is for any structure other than residential principal structure (house) to include, but not limited to: garage,
shed, dock, deck, carport, pole barn, greenhouse, etc. Refer to Informational Brochure No. 3—Accessory Structures —
Sheds/Fences.
3. Changes to Plan — Any changes prior to or during construction will require submittal of amended plans (review and re-
approval are necessary)
4. Withdrawn Permits: 20%of the initial fee is retainable by the Town. No fee is refundable after 1 year from initial application
date.
5. Additional review: All applications are subject to Zoning Administrator, Code Compliance and Structural Plan Review.
CHANGES TO RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011(INFORMATIONAL):
Residential Building Code
• New driveway requirements for structures located over 300 feet from main road
• Spray foams are allowed to be exposed in rim joist box only,must be covered by 15 minute thermal barrier all other areas;
• Protection against decay requirements
• Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing
over steps
• Vent stacks must be 18 inches minimum above roof for all structures
New Electrical Reguirements
• Arc fault breakers required in all habitable spaces for receptacles
• GFI protection for all other receptacles in kitchens, bathrooms, garages and unfinished basements
• All receptacles must be tamper resistant
• Carbon Monoxide detectors must be located within 15 feet of sleeping areas;
• All corrugated stainless steel piping must be bonded to the common ground for electrical service
New Energy Code
• Blower door tests required by credential contractor or structure inspection by air barrier supplier and certified compliant
• Programmable thermostats required
• Lighting must be 50%energy saving light bulbs
• Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit
• ResCheck inspector's checklist must be available at time of insulation inspection
2
Town of Queensbury Building&Codes Accessory Structure Application July 2014
Town of Queensbury Building & Code Enforcement
Office No. (518) 761-8256 - I�
Framing / Firestopping Inspection Report
Inspection request r ceived: 5,2t�15
Name: z24,\e-$A Inspected on:
Location: 2bArrive: SA X b a.m./p.m.
Permit No.: I A-`Jl3 Inspector's Initials: t
TYPE OF STRUCTURE: a Y&I
Framing N NIA COMMENTS:
Attic Access 22"x 30°minimum
Jack Studs I Headers
Truss Specification Provided
Bracing/Bridging
Joist hangers
Jack Posts I Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in.or more
Exterior Deck Bracing
Headroom 6 ft.8 in.
Notches/Holes I Bearing Walls
Metal Strapping for Notches Top Plate
1 '%(w)16 gauge(8)16D nails each side
Draft stopping 1,000 sq.ft.Floor trusses
Anchor Bolts 6 ft.or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%,inch or 518 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space I Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above I below grade
5.0 sf grade
Design Professional Sign-off,if required
Framing 1 Firestopping Inspection Report
ITED NOVEMBER 24, 1999 MAGNETIC
3Y VAN DUSEN & STEVES
CgRT
/ IRF pq�Iy
X30
1 %_' 2014
/ IRF
so N07°30 50,,E
f / �, � 76.82
LOT 4 r �
' m
F�rz'!I,71T PI CST Le—I
sti p• I rlAVE PERSONALLY MEASURED THE(DISTANCE
LOT 3 f _ FROM THE PR(�F'ERTI'I-IINES TO THE
f 28,963 sq. ft. PORC
/ 0.66 acres WOOD
STpq�, H ..TU ( ' R SIGN(S)
pU ggiy�E I SIGI E
/ SE DATE
OROH � II o
f a / CO io
J Co LOT 2
p¢ f `\ \ / C
V� L=132.44 � �� \c� � ; o
IF �
4 IRF&
o °
0.
T0-8
o �R rs- s
s C
oN
so UT
F